Sie sind auf Seite 1von 2

Category 6

S/FTP 4 Pair Cable


Norden Category 6 S/FTP cables exceed Category 6/Class E
specification.It is tested to 250MHz frequency range and designed
to support Gigabit 1000Base-T and 1000Base-Tx applications to full
100m. Norden Category 6 S/FTP cables are UL listed CM, CMX, CMR
& CMP.
Data integrity is one of the most essential network requirements for
many corporations, especially those located in environments that are
prone to noise and electromagnetic interference such as industrial
facilities and airports, as well as those running critical systems such as
military installations and hospitals. S/FTP (Foil Twisted Pair - Shielded)
cabling systems are installed to protect data from potentially
corrupting electromagnetic interference (EMI) and improved Alien
Cross talk performance.

1
2
3
4

Outer Jacket

Braid Screen

Center Conductor

Insulation

Foil Shield

Rip Cord

5
6

COMPLIANCE
IEEE 802.af, IEEE 802.3at for PoE applications
UL 444, ANSI/TIA-568-C.2:2009 Category 6
ISO/IEC-11801, 2nd Edition Class E
IEC 61156-5:2002 Category 6
Flammability grade available on CM, CMX, CMR & CMP
LSZH: IEC 60332-1, IEC 60754, IEC 61034

NORDEN PRODUCT CATALOGUE

DATA CABLES

MATERIAL CONSTRUCTION & DESIGN


Conductor Material:
Conductor Size:
Conductor Construction:
Insulation Material:
Insulation Diameter:
Conductor Unit Identification:
Rip Cord :
Drain Wire:
Colour Code:
Ind. Shield Material:
Ind. Shield Design:
Conductor Unit lay-Up:
Overall Shield Design:
Overall Shield Material:
Braid Coverage:
Total Number of Wires:
Outer Jacket:
Outer Jacket Thickness & Ex. Diameter:
Outer Jacket Colour:
Marking:

47

Bare Copper
0.51 mm(D) norm., 23 AWG
Solid
High Density PE
1.36mm
Solid/Stripe
Yes
N/A
Per TIA/EIA 568-B
Aluminium Foil
100% Coverage
Pairs
Braid
Tinned-Copper, 0.10mm
45 % nom.
8
LS0H Halogen Free flame retardant or PVC
0.550.05mm, 7.90.5mm
Per Requirement
Per Requirement

Category 6
S/FTP 4 Pair Cable
ELECTRICAL, MECHANICAL & TRANSMISSION CHARACTERISTICS
Frequency Range:
Impedance:
Coupling Attenuation:
DC Resistance:
Max. Resistance Unbalance:
Capacitance:
Capacitance Unbalance:
Propagation Delay Skew:
Velocity of Propagation:
Dielectric Strength:
Min. Insulation Resistance :
Max. Tensile Strength Short Term:
Transfer Impedance:

1 - 250 MHz
100 +/-15
85 dB min @ 30-100 MHz 85-20Log(f/100) @100-250 MHz
73 /km nom.
4%
5.6nF/100m max.
3.3 pF/m max.
35 ns/100m max.
69%
1KV/minute
5 Gkm
110N
50 m/m max @ 1 MHz.
100 m/m max @ 10 MHz.
200 m/m max @ 30 MHz.
1000 m/m max @ 100 MHz.
58mm
+60 C
-10 C

Min. Bend Radius:


Max. Operating Temperature:
Min. Operating Temperature:

ELECTRICAL PERFORMANCE CHARACTERISTICS


Cat. 6 screened Pair Horizontal Cables*
Freq.
MHz
1
4
10
20
31.25
100
150
200
250

Attenuation
dB/100m@20C
2.0
3.8
6.0
8.5
10.4
19.8
24.7
29.0
32.8

NEXT
dB
80.0
75.0
71.0
62.0
60.9
54.0
50.7
48.1
46.3

PSNEXT
dB
78.0
72.8
69.0
60.2
58.9
52.0
48.7
46.1
44.3

RL
dB
27.0
30.0
30.0
30.0
28.6
26.0
25.1
23.8
22.0

ELFEXT
dB
81.8
76.8
70.0
58.8
56.8
47.8
43.3
38.8
36.8

PSELFEXT
dB
77.8
73.8
67.8
55.8
53.3
44.8
40.3
35.8
33.8

*Supplied cables meet the minimum Cat. 6 transmission requirements as per IEC 61156-5 Ed. 2

ORDERING INFORMATION
DESCRIPTION
Category 6 S/FTP 4 Pair Cable PVC
Category 6 S/FTP 4 Pair Cable LSZH

LENGTH (STANDARD)
305 mtr
305 mtr
X: BK(Black), BL(Blue), GN(Green), GY(Gray), RD(Red), WH(White), YL(Yellow)

PACKING INFORMATION
Packing Mode
Ply Reel
Ply Reel

www.nordencommunication.com

N.W
(kg)
17.5
57.3

G.W
(kg)
19.0
64.0

Dimension
(cm)
42.0 x 42.0 x 26.0
47.0 x 47.0 x 42.0

NORDEN PRODUCT CATALOGUE

Cable Length
(Metre)
305
1000

DATA CABLES

PART NUMBER
113-11001504X
113-11002504X

48