Sie sind auf Seite 1von 48

2

High performance steel anchors

High performance steel anchors

Steel anchors

FAZ II anchor bolt


FBN II anchor bolt
FH II high performance anchor
FZA / FZA-D / FZA-I Zykon undercut anchors
FZEA II Zykon hammerset anchor
FBS concrete screw
EA II hammerset anchor
FNA II nail anchor

3
6
10
16
21
24
29
32

T AM-T BP security anchor


FA throughbolt
FSA sleeve anchor
FWB wallbolt
FDBB fixing set for diamond drills
FHY hollow ceiling anchor

35
36
37
40
43
44

FAZ II Anchor
bolt
Bolt anchor
Efficient fixing for cracked concrete

Cable trays

VERSIONS

APPROVALS

zinc-plated steel
stainless steel
highly corrosion-resistant steel

BUILDING MATERIALS
Approved for:
Concrete C20/25 to C50/60,
cracked and non-cracked
Also suitable for:
Concrete C12/15
Natural stone with dense structure

High performance steel anchors

Balcony railings

ADVANTAGES

APPLICATIONS

FUNCTIONING

The expansion clip allows for a high


load-bearing capacity, thus fewer fixing
points and smaller anchor plates are
required.
The international approvals guarantee
maximum safety and the best
performance.
The bolt geometry provides maximum
load distribution which enables use
close to edges and in thin components.
Fewer hammer blows and minimal
torque slippage provides a more
simplified installation process
The drive-in pin protects the thread
from damage and ensures a troublefree dismantling of the fixture.

Steel constructions
Guard rails
Consoles
Ladders
Cable conduits
Machines
Staircases
Gates
Faades
Wood constructions

The FAZ II is suitable for pre-positioned


and push-through installation; also
suitable for stand-off installation under
certain conditions.
Prior to installation, place the hexagon
nut in the optimal position (the drive-in
pin projects by approx. 3 mm out of the
hexagon nut).
When applying the torque, the cone
bolt is pulled into the expansion clip
and expands it against the drill hole
wall.
The head embossing offers a simple
control of the anchoring.
In the case of series installation, we
recommend using the FABS anchor
bolt setting tool.

INSTALLATION

FAZ II Anchor bolt

Bolt anchor FAZ II

Items to order only

Item

FAZ II 8/10
FAZ II 8/10
FAZ II 8/30
FAZ II 8/30
FAZ II 8/50
FAZ II 8/100
FAZ II 8/160
FAZ II 10/10
FAZ II 10/10
FAZ II 10/20
FAZ II 10/20
FAZ II 10/30
FAZ II 10/30
FAZ II 10/30
FAZ II 10/50
FAZ II 10/70
FAZ II 10/80
FAZ II 10/100
FAZ II 10/160
FAZ II 12/10
FAZ II 12/10
FAZ II 12/20
FAZ II 12/30
FAZ II 12/30
FAZ II 12/50
FAZ II 12/60
FAZ II 12/80
FAZ II 12/100
FAZ II 12/160
FAZ II 12/160
FAZ II 12/200
FAZ II 16/25
FAZ II 16/25
FAZ II 16/50
FAZ II 16/50
FAZ II 16/100
FAZ II 16/160
FAZ II 16/200
FAZ II 16/250
FAZ II 16/300
FAZ II 20/30
FAZ II 20/30
FAZ II 20/60
FAZ II 20/60
FAZ II 20/160
FAZ II 24/30
FAZ II 24/30
FAZ II 24/60
FAZ II 24/60

zinc-plated
steel

stainless
steel

highly
corrosion
resistant
steel

Drill hole
diameter

Art.-No.
gvz

Art.-No.
A4

Art.-No.
C

ETA

ICC

094871

094877

094878
094879
503251
094981

094982

094983

094984

094985
094986
503252
095419

095420
095421

095446

095454
095470
503253

095605

095836
095864

095865
503254
095967
095968
096188
046632

046633

503255
046635

046636

501396

501399

501401

501403

501406

501407

501409
501410

501411
501412
501413

501415
501416

501419
501420

501421

503180

501423

501424
501425

501426

503183

501427

503184

501428

501429

501430

503185

503186

501431

501432
503187

Approval

High performance steel anchors

TECHNICAL DATA

Anchor
length

do

Min. drillhole depth


for through
fixings
h2

[mm]

[mm]

8
8
8
8
8
8
8
10
10
10
10
10
10
10
10
10
10
10
10
12
12
12
12
12
12
12
12
12
12
12
12
16
16
16
16
16
16
16
16
16
20
20
20
20
20
24
24
24
24

65
65
85
85
105
155
215
85
85
95
95
105
105
105
125
145
155
175
235
100
100
110
120
120
140
150
170
190
250
250
290
135
135
160
160
210
270
310
360
410
155
155
185
185
285
185
185
215
215

75
75
95
95
115
165
225
95
95
105
105
115
115
115
135
155
165
185
245
110
110
120
130
130
150
160
180
200
260
260
300
148
148
173
173
223
283
323
373
423
172
172
202
202
302
205
205
235
235

FAZ II GS 8/10/12/16 with large washers also available to order, please ask for details

Max. fixture
thickness

Thread

Width
across nut

Sales
unit

t fix

x length

SW

[mm]

[mm]

[mm]

[mm]

[pcs]

10
10
30
30
50
100
160
10
10
20
20
30
30
30
50
70
80
100
160
10
10
20
30
30
50
60
80
100
160
160
200
25
25
50
50
100
160
200
250
300
30
30
60
60
160
30
30
60
60

M 8 x 21
M 8 x 21
M 8 x 41
M 8 x 41
M 8 x 61
M 8 x 100
M 8 x 100
M 10 x 24
M 10 x 24
M 10 x 34
M 10 x 34
M 10 x 44
M 10 x 44
M 10 x 44
M 10 x 64
M 10 x 84
M 10 x 94
M 10 x 100
M 10 x 100
M 12 x 27
M 12 x 27
M 12 x 37
M 12 x 47
M 12 x 47
M 12 x 67
M 12 x 77
M 12 x 97
M 12 x 100
M 12 x 100
M 12 x 100
M 12 x 100
M 16 x 47
M 16 x 47
M 16 x 72
M 16 x 72
M 16 x 100
M 16 x 100
M 16 x 100
M 16 x 100
M 16 x 100
M 20 x 54
M 20 x 54
M 20 x 84
M 20 x 84
M 20 x 100
M 24 x 58
M 24 x 58
M 24 x 88
M 24 x 88

13
13
13
13
13
13
13
17
17
17
17
17
17
17
17
17
17
17
17
19
19
19
19
19
19
19
19
19
19
19
19
24
24
24
24
24
24
24
24
24
30
30
30
30
30
36
36
36
36

50
10
50
10
50
25
20
50
10
25
50
25
50
10
20
20
20
20
20
20
10
20
20
10
20
20
20
20
10
20
10
20
20
10
20
10
10
10
10
10
5
4
5
4
5
5
4
5
4

FAZ II Anchor bolt


ACCESSORIES

Sales unit
[pcs]

Fits anchor
Item

FABS

Art.-No.

077937

FAZ II, FBN II, EXA for diameter from M6 - M12

LOADS
Bolt anchor FAZ II
Highest permissible loads for a single anchor1) in concrete C20/254)
For the design the complete approval ETA - 05/0069 has to be considered.
Type

FAZ II 8
FAZ II 10
FAZ II 12
FAZ II 16
FAZ II 20
FAZ II 24

Cracked concrete
Effective
Min.
Installation Permissible Permissible
Min.
anchorage member
torque tensile load shear load spacing
depth
thickness5)
hef
hmin
Tinst
Nperm3)
Vperm3)
smin2)

Non-cracked concrete
Min.
Permissible Permissible
Min.
edge
tensile load shear load spacing
distance
cmin2)
Nperm3)
Vperm3)
smin2)

Min.
edge
distance
cmin2)

[mm]

[mm]

[Nm]

[kN]

[kN]

[mm]

[mm]

[kN]

[kN]

[mm]

[mm]

45
60
70
85
100
125

100
120
140
170
200
250

20,0
45,0
60,0
110,0
200,0
270,0

2,4
4,3
7,6
13,4
17,1
24,0

6,9
11,4
16,9
31,4
40,0
49,1

35
40
45
60
95
100

40
45
55
65
85
100

4,3
7,6
11,9
18,8
24,0
33,6

6,9
11,4
16,9
31,4
40,0
49,1

40
40
50
60
95
100

40
45
55
65
95
135

LOADS

Bolt anchor FAZ II A4


Highest permissible loads for a single anchor1) in concrete C20/254) .
For the design the complete approval ETA - 05/0069 has to be considered.
Type

FAZ II 8 A4
FAZ II 10 A4
FAZ II 12 A4
FAZ II 16 A4
FAZ II 20 A4
FAZ II 24 A4

High performance steel anchors

fischer Anchor bolt setting tool FABS

Cracked concrete
Installation Permissible Permissible
Min.
Effective
Min.
torque tensile load shear load spacing
anchorage member
depth
thickness5)
hef
hmin
Tinst
Nperm3)
Vperm3)
smin2)

Non-cracked concrete
Min.
Permissible Permissible
Min.
edge
tensile load shear load spacing
distance
cmin2)
Nperm3)
Vperm3)
smin2)

Min.
edge
distance
cmin2)

[mm]

[mm]

[Nm]

[kN]

[kN]

[mm]

[mm]

[kN]

[kN]

[mm]

[mm]

45
60
70
85
100
125

100
120
140
170
200
250

20,0
45,0
60,0
110,0
200,0
270,0

2,4
4,3
7,6
13,4
17,1
24,0

6,9
11,4
16,9
31,4
40,0
49,1

35
40
45
60
95
100

40
45
55
65
85
100

4,3
7,6
11,9
18,8
24,0
33,6

6,9
11,4
16,9
31,4
40,0
49,1

40
40
50
60
95
100

40
45
55
65
95
135

LOADS
Bolt anchor FAZ II C
Highest permissible loads for a single anchor1) in concrete C20/254)
For the design the complete approval ETA - 05/0069 has to be considered.
Type

FAZ II 8 C
FAZ II 10 C
FAZ II 12 C
FAZ II 16 C
FAZ II 20 C
FAZ II 24 C

Cracked concrete
Effective
Min.
Installation Permissible Permissible
Min.
anchorage member
torque tensile load shear load spacing
depth
thickness5)
hef
hmin
Tinst
Nperm3)
Vperm3)
smin2)

Min.
edge
distance
cmin2)

[mm]

[mm]

[Nm]

[kN]

[kN]

[mm]

[mm]

[kN]

[kN]

[mm]

[mm]

45
60
70
85
100
125

100
120
140
170
200
250

20,0
45,0
60,0
110,0
200,0
270,0

2,4
4,3
7,6
13,4
17,1
24,0

6,9
11,4
16,9
31,4
40,0
49,1

35
40
45
60
95
100

40
45
55
65
85
100

4,3
7,6
11,9
18,8
24,0
33,6

6,9
11,4
16,9
31,4
40,0
49,1

40
40
50
60
95
100

40
45
55
65
95
135

The partial safety factors for material resistance as regulated in the approval as well as a partial
safety factor for load actions of L = 1,4 are considered. As an single anchor counts e.g. an anchor
with a spacing s 3 x hef and an edge distance c 1,5 x hef. Accurate data see approval.
2)
Minimum possible axial spacings resp. edge distance while reducing the permissible load for the
minimum member thickness (hmin 2 x hef). The combination of the given min. spacing and min.
edge distance is not possible. One of them has to be increased according approval.
1)

Non-cracked concrete
Min.
Permissible Permissible
Min.
edge
tensile load shear load spacing
distance
cmin2)
Nperm3)
Vperm3)
smin2)

For combination of tensile loads, shear loads, bending moments as well as reduced edge distances
or spacings (anchor groups) see approval.
4)
For higher concrete strength classes up to C50/60 higher permissible loads may be possible.
5)
According approval the minimum member thickness (hmin 2 x hef) can be reduced under specific
conditions.
3)

High performance steel anchors

FBN II Anchor bolt


The cost-efficient fixing for flexible use in non-cracked
concrete

Stormwater overflow tank manholes

VERSIONS

APPROVALS

zinc-plated steel
stainless steel
hot-dip galvanised steel

BUILDING MATERIALS
Approved for:
Concrete C20/25 to C50/60, noncracked
Also suitable for:
Concrete C12/15
Natural stone with dense structure

2
ADVANTAGES

APPLICATIONS

FUNCTIONING

The standard anchorage depth


achieves the maximum load-bearing
capacities so fewer fixing points and
smaller anchor plates are required.
The reduced anchorage depth reduces
the drill hole depth. This minimises the
amount of time needed for installation
whilst increasing more flexible areas of
use.
The long thread allows flexible fixture
thickness for stand-off installations.
With only a few hammer blows and
minimal torque slippage installation is
a simple process.
The drive-in pin protects the thread
from damage, and ensures a faster
installation and dismantling of the
attachment.

Steel constructions
Guard rails
Consoles
Ladders
Cable conduits
Machines
Staircases
Gates
Faades

The FBN II is suitable for pre-positioned


and push-through installation; also
suitable for stand-off installation under
certain conditions.
Prior to installation, place the hexagon
nut in the optimal position so that the
drive-in pin projects by approx. 3 mm
out of the hexagon nut.
When applying torque, the cone is
pulled into the expansion clip and
expands it against the drill hole wall.
The embossed head offers a simple
control of the anchoring.
For a series of installations we
recommend using the FABS bolt
anchor setting tool.

INSTALLATION

Column bases

FBN II Anchor bolt


TECHNICAL DATA

Item

FBN II 6x5 (6/5)


FBN II 6x55 (6/10)
FBN II 6x75 (6/30)
FBN II 8x65 (8/65)
FBN II 8x55 K (8/5)
FBN II 8x55 K (8/55)
FBN II 8x60 K (8/10)
FBN II 8x70 (8/10)
FBN II 8x70 (8/10)
FBN II 8x80 (8/20)
FBN II 8x90 (8/20)
FBN II 8x90 (8/20)
FBN II 8x110 (8/50)
FBN II 8x110 (8/50)
FBN II 8x130 (8/70)
FBN II 10x70 K (10/5)
FBN II 10x70 K (10/5)
FBN II 10x75 K (10/10)
FBN II 8x130 (8/70)
FBN II 8x160 (8/100)
FBN II 10x85 (10/10)
FBN II 10x85 (10/10)
FBN II 10x95 (10/20)
FBN II 10x105 (10/30)
FBN II 10x105 (10/30)
FBN II 10x125 (10/50)
FBN II 10x125 (10/50)
FBN II 10x145 (10/70)
FBN II 10x175 (10/100)
FBN II 10x175 (10/100)
FBN II 10x215 (10/140)
FBN II 10x235 (10/160)
FBN II 12x85 K (12/5)
FBN II 12x90 K (12/5)
FBN II 12x90 K (12/5)
FBN II 12x105 (12/10)
FBN II 12x105 (12/10)
FBN II 12x110 K (12/30)
FBN II 12x115 (12/20)
FBN II 12x125 (12/30)
FBN II 12x125 (12x30)
FBN II 12x145 (12/50)
FBN II 12x145 (12/50)
FBN II 12x175 (12/80)
FBN II 12x195 (12/100)
FBN II 12x195 (12/100)
FBN II 12x215 (12/120)
FBN II 12x235 (12/140)
FBN II 12x255 (12/160)
FBN II 16x130 (16/10)

stainless
steel

hot-dip
galvanised
steel

Approval

Items to order only

zinc-plated
steel

Drill hole Min. Drill


diameter hole depth
for through
fixings
h2
do

Thread

Width
across
nut

Max.
usable length
hef,standard/
hef,reduced
tfix

x length

SW

Anchor
length

Sales
unit

Art.-No.
gvz

Art.-No.
A4

Art.-No.
fvz

ETA

[mm]

[mm]

[mm]

[mm]

[mm]

[mm]

[pcs]

505526 1) 2)
505527 1) 2)
505528 1) 2)
040662
040806

040807
040664

040669
040700

040771

040777
040946

040947

040783
040827

040851
040854

040855

040931
040943

040944
040945
045272

045273
040950

045274
044558
045263

045264

045265
045266

045267
045268
045269

505532 1) 2)
505535 1) 2)

508007

507555

507556

507557

508010

507558

507559
507560

507561

507562

508011

507563

507564
507565

507566

507567

507568

508012

507575

507576

507577

508013

507578

507579

507580

507582

507583

508014

507589

507591

507592

507596

6
6
6
8
8
8
8
8
8
8
8
8
8
8
8
10
10
10
8
8
10
10
10
10
10
10
10
10
10
10
10
10
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
16

45
50
70
61
51
51
56
66
66
76
86
86
106
106
126
63
63
68
126
156
78
78
88
98
98
118
118
138
168
168
208
228
75
75
80
95
95
100
105
115
115
135
135
165
185
185
205
225
245
114

50
55
75
66
56
56
61
71
71
81
91
91
111
111
131
71
71
76
131
161
86
86
96
106
106
126
126
146
176
176
216
236
86
86
91
106
106
111
116
126
126
146
146
176
196
196
216
236
256
130

5/10/ 30/5/15
-/5
-/5
-/10
10/20
10/20
20/30
30/40
30/40
50/60
50/60
70/80
-/5
-/5
-/10
70/80
100/110
10/20
10/20
20/30
30/40
30/40
50/60
50/60
70/80
100/110
100/110
140/150
160/170
-/5
-/5
-/10
10/25
10/25
-/30
20/35
30/45
30/45
50/65
50/65
80/95
100/115
100/115
120/135
140/155
160/175
10/25

M 6 x 12
M 6 x 17
M 6 x 35
M 8 x 34
M 8 x 24
M 8 x 24
M 8 x 29
M 8 x 39
M 8 x 39
M 8 x 49
M 8 x 59
M 8 x 59
M 8 x 79
M 8 x 79
M 8 x 99
M 10 x 31
M 10 x 31
M 10 x 36
M 8 x 99
M 8 x 129
M 10 x 46
M 10 x 46
M 10 x 56
M 10 x 66
M 10 x 66
M 10 x 86
M 10 x 86
M 10 x 106
M 10 x 136
M 10 x 136
M 10 x 176
M 10 x 196
M 12 x 39
M 12 x 39
M 12 x 44
M 12 x 59
M 12 x 59
M 12 x 64
M 12 x 69
M 12 x 79
M 12 x 79
M 12 x 99
M 12 x 99
M 12 x 129
M 12 x 149
M 12 x 149
M 12 x 169
M 12 x 189
M 12 x 189
M 16 x 74

10
10
10
13
13
13
13
13
13
13
13
13
13
13
13
17
17
17
13
13
17
17
17
17
17
17
17
17
17
17
17
17
19
19
19
19
19
19
19
19
19
19
19
19
19
19
19
19
19
24

100
100
100
50
50
50
50
50
50
50
50
50
50
50
20
50
50
50
20
20
50
50
50
50
50
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
10

High performance steel anchors

Bolt anchor FBN II

FBN II Anchor bolt

Items to order only

zinc-plated
steel

stainless
steel

hot-dip
galvanised
steel

Approval

High performance steel anchors

TECHNICAL DATA
Drill hole
diameter
do

Min. drill
hole depth
for through
fixings
h2

Anchor
length
l

Max. usable
length
hef,standard/
hef,reduced
tfix

Thread

x length

ETA
[mm]
[mm]
[mm]
[mm]
[mm]
Art.-No.
Art.-No.
Art.-No.
Item
gvz
A4
fvz
FBN II 16x120 K (16/15)
045571
508745

16
104
120
-/15
M 16 x 64
FBN II 16x145 K (16/15)

507597

16
104
120
-/15
M 16 x 64
FBN II 16x130 K (16/25)
045572

16
114
130
-/25
M 16 x 74
FBN II 16x260 (16/140)
045568

16
244
260
140/155
M 16 x 184
FBN II 16x280 (16/160)
045569

16
264
280
160/175
M 16 x 184
FBN II 16x320 (16/200)
045570

16
304
320
200/215
M 16 x 100
FBN II 20x10 K (20/10)
045577

20
120
142
-/10
M 20 x 50
FBN II 20x185 (20/30)
045573
507571

20
165
187
30/55
M 20 x 90
FBN II 20x185 (20/30)

508015

20
165
187
30/55
M 20 x 90
FBN II 20x215 (20/60)
045574
507572

20
195
217
60/85
M 20 x 90
FBN II 20x235 (20/80)
045575

20
215
237
80/105
M 20 x 90
FBN II 20x275 (20/120)
045576

20
255
277
120/145
M 20 x 90
1) Use restricted to anchoring of structural components which are statically indeterminate. 2) Nut and washer not pre-assembled/supplied loose.

Width
across
nut

Sales
unit

SW
[mm]

[pcs]

24
24
24
24
24
24
30
30
30
30
30
30

10
10
10
10
10
10
10
10
50
10
10
10

ACCESSORIES
fischer Anchor bolt setting tool FABS
Item

FABS

Art.-No.

077937

Sales unit [pcs]

Fits anchor

FAZ II, FBN II, EXA for diameter from M6 - M12

ACCESSORIES

Torque wrench FTW8-54

width
across nut

Items to order only


Type

FTW 8-54
FTW 50-230
Deep drive socket
FDDP 10
FDDP 13
FDDP 17
FDDP 19

Torque wrench drive FTW 50-230

Deep drive socket FDDP 1/2

torque

Art.-No.

[mm]

[Nm]

503324
503325

8-54
50-230

hex. head fixings


hex. head fixings

503326
503327
503328
503329

10 A/F
13 A/F
17 A/F
19 A/F

M6
M8
M10
M12

For further detailed information on this product range please contact our Technical Team of advisors on 01491 827 920

suitable for

Sales unit

[pcs]

1
1
1
1
1
1
1

FBN II Anchor bolt


LOADS
Bolt anchor FBN II. Highest permissible loads for a single anchor1) in concrete C20/254)
For the design the complete approval ETA - 07/0211 has to be considered.
Min. effective
anchorage depth
hef,min
[mm]

FBN II 65)

Max. effective
anchorage depth
hef,max
[mm]
30

30

FBN II 85)

40
40

FBN II 10

50
50

FBN II 12

65
65

FBN II 16

80
80

FBN II 20

105

Min. member
thickness
hmin
[mm]
100
100
100
100
100
100
120
120
160
160
200

The partial safety factors for material resistance as regulated in the approval as well as a partial
safety factor for load actions of L = 1,4 are considered. As an single anchor counts e.g. an anchor with a spacing s 3 x hef and an edge distance c 1,5 x hef. Accurate data see approval.
2)
Minimum possible axial spacings resp. edge distance while reducing the permissible load.
3)
For combinations of tensile loads, shear loads, bending moments as well as reduced edge

Installation
torque
Tinst
[Nm]
4,0
15,0
15,0
30,0
30,0
50,0
50,0
100,0
100,0
200,0
200,0

1)

4)
5)

Permissible
tensile load
Nperm3)
[kN]
2,9
2,9
6,1
6,1
8,5
8,5
12,6
12,6
17,2
17,2
25,9

Non-cracked concrete
Permissible
Min.
shear load
spacing
Vperm3)
smin2)
[kN]
[mm]
2,7
50
4,0
40
6,1
40
6,1
50
8,5
50
8,5
70
14,3
70
25,2
90
26,9
90
34,4
120
38,3
120

Min.
edge distance
cmin2)
[mm]
100
40
40
80
50
100
70
120
90
120
120

distances or spacings (anchor groups) see approval.


For higher concrete strength classes up to C50/60 higher permissible loads may be possible.
The anchorage depths smaller than 40 mm are only allowed for multiple use for non-structural
applications.

LOADS

Bolt anchor FBN II A4. Highest permissible loads for a single anchor1) in concrete C20/254)
For the design the complete approval ETA - 07/0211 has to be considered.
Type

FBN II 8 A4

5)

FBN II 10 A4
FBN II 12 A4
FBN II 16 A4
FBN II 20 A4

Non-cracked concrete
Permissible
Min.
shear load
spacing
Vperm3)
smin2)

Min. effective
anchorage depth
hef,min

Max. effective
anchorage depth
hef,max

Min. member
thickness
hmin

Installation
torque
Tinst

Permissible
tensile load
Nperm3)

[mm]

[mm]

[mm]

[Nm]

[kN]

[kN]

[mm]

[mm]

30

100
100
100
100
100
100
120
120
160
160
200

4,0
10,0
10,0
20,0
20,0
35,0
35,0
80,0
80,0
150,0
150,0

2,9
2,9
6,1
6,1
8,5
8,5
12,6
12,6
17,2
17,2
25,9

3,0
4,0
6,1
6,1
8,5
8,5
15,7
25,2
29,1
34,4
49,1

50
50
40
50
70
70
70
90
120
140
120

100
45
45
80
55
100
70
120
80
120
120

FBN II 6 A4 5)
30

40
40
50
50
65
65
80
80
105

The partial safety factors for material resistance as regulated in the approval as well as a partial
safety factor for load actions of L = 1,4 are considered. As an single anchor counts e.g. an anchor with a spacing s 3 x hef and an edge distance c 1,5 x hef. Accurate data see approval.
2)
Minimum possible axial spacings resp. edge distance while reducing the permissible load.
3)
For combinations of tensile loads, shear loads, bending moments as well as reduced edge
1)

4)
5)

High performance steel anchors

Type

Min.
edge distance
cmin2)

distances or spacings (anchor groups) see approval.


For higher concrete strength classes up to C50/60 higher permissible loads may be possible.
The anchorage depths smaller than 40 mm are only allowed for multiple use for non-structural
applications.

High performance steel anchors

FH II High performance anchor


The push-through anchor for fixings with sophisticated design
in cracked concrete

Steel girders

Banisters

VERSIONS

APPROVALS

zinc-plated steel
stainless steel

BUILDING MATERIALS
Approved for:
Concrete C20/25 to C50/60,
cracked and non-cracked
Also suitable for:
Concrete C12/15
Natural stone with dense structure

2
FH II-I Internally
threaded

ADVANTAGES

APPLICATIONS

The anchor construction has a wide


range of head shapes for fixing points
with sophisticated design.
The interaction between the screw
shank and sleeve provides a high shear
load so less fixing points are required.
International approvals guarantee
maximum safety and high performance.
The geometry of the anchor reduces
the amount of energy required for
installation.
The detachable screw allows for
surface flush removal.
FH II-I Internally threaded version also
available

Guard rails
Staircases
Consoles
Steel constructions
Ladders
Cable conduits
Machines
Gates
Faades
Gratings

INSTALLATION

FUNCTIONING
The FH II is suitable for push-through
installation.
When applying the torque, the cone is
pulled into the expansion sleeve and
expands it against the drill hole wall.
The black plastic ring prevents rotation
when tightening the anchor, and acts
as a crumple zone to take the torque
slippage so that the fixture is pulled
onto the anchor base.
Available head shapes for flexible
design solutions:
Countersunk head (type SK - for surface
flush and fixing points that can be
subsequently secured against theft),
hexagon head (type S), bolt version
with nut and washer (type B) and cap
nut (type H).

FHII-I high
performance anchor

FHII-I internally
threaded anchor

10

FH II High performance anchor


TECHNICAL DATA

Item

FH II 10/10 S
FH II 10/10 S
FH II 10/25 S
FH II 10/25 S
FH II 10/50 S
FH II 12/10 S
FH II 12/10 S
FH II 12/25 S
FH II 12/25 S
FH II 12/50 S
FH II 15/10 S
FH II 15/10 S
FH II 15/25 S
FH II 15/25 S
FH II 15/50 S
FH II 18/10 S
FH II 18/25 S
FH II 18/25 S
FH II 18/50 S
FH II 24/25 S
FH II 24/25 S
FH II 24/50 S
FH II 28/30 S
FH II 28/60 S
FH II 32/30 S
FH II 32/60 S

zinc-plated stainless
steel
steel

Drill hole
diameter
do

Min. drill
hole depth for
through fixings
h2

t fix

Art.-No.
gvz

Art.-No.
A4

ETA

ICC

[mm]

[mm]

[mm]

[mm]

503133

503134

503135
044884

044885

044886
044887

044888

044889
046847
044894

044896
044898

044900
044901
044902
044903
044904

510923

510924

510925

510926

510927

510928

510929

502711

10
10
10
10
10
12
12
12
12
12
15
15
15
15
15
18
18
18
18
24
24
24
28
28
32
32

65
65
80
80
105
90
90
105
105
130
100
100
115
115
140
115
130
130
155
150
150
175
185
215
210
240

70
69
85
84
110
90
90
105
105
130
106
107
121
122
146
118
132
133
157
160
160
185
192
222
215
245

10
10
25
25
50
10
10
25
25
50
10
10
25
25
50
10
25
25
50
25
25
50
30
60
30
60

Approval

Items to order only

Anchor
length

Max. fixture
thickness

Thread
M

Width
across nut

Sales unit

SW
[mm]

[pcs]

M6
M6
M6
M6
M6
M8
M8
M8
M8
M8
M 10
M 10
M 10
M 10
M 10
M 12
M 12
M 12
M 12
M 16
M 16
M 16
M 20
M 20
M 20
M 24

10
10
10
10
10
13
13
13
13
13
17
17
17
17
17
19
19
19
19
24
24
24
30
30
36
36

50
50
50
50
50
50
50
50
20
25
25
50
25
20
25
20
20
10
20
10
8
10
4
4
4
4

Max. fixture
thickness

Thread

Width across
nut (hexagon
socket)

Sales unit

M
[mm]

[pcs]

4
4
4
5
6
5
6
5
6

50
50
50
25
25
25
25
25
25

High performance steel anchors

High performance anchor FH II-S - with


hexagonal head

TECHNICAL DATA

High performance anchor FH II-SK with


countersunk head

Item

FH II 10/15 SK
FH II 10/25 SK
FH II 10/50 SK
FH II 12/15 SK
FH II 12/15 SK
FH II 12/25 SK
FH II 12/30 SK
FH II 12/50 SK
FH II 12/50 SK

stainless
steel

Art.-No.
gvz

Art.-No.
A4

503136

503137

503138

044917

510931
044918

510932
044919

510933

Drill hole
diameter
do

Min. drill
hole depth
for through
fixings
h2

t fix

ETA

ICC

[mm]

[mm]

[mm]

[mm]

10
10
10
12
12
12
12
12
12

70
80
105
95
95
105
110
130
130

65
75
100
90
90
100
105
125
125

10
25
50
15
15
25
30
50
50

Approval

Items to order only

zinc-plated
steel

Anchor
length

M6
M6
M6
M8
M8
M8
M8
M8
M8

11

FH II High performance anchor


High performance anchor FH II-SK with
countersunk head
zinc-plated stainless
steel
steel

Items to order only

Art.-No.
gvz

Item

FH II 15/15 SK
FH II 15/15 SK
FH II 15/25 SK
FH II 15/50 SK
FH II 18/15 SK
FH II 18/25 SK
FH II 18/30 SK
FH II 18/50 SK

Drill hole
diameter

Approval

High performance steel anchors

TECHNICAL DATA

Art.-No.
A4

Anchor
length

Max. fixture
thickness

Thread

do

Min. drill
hole depth
for through
fixings
h2

t fix

ETA

ICC

[mm]

[mm]

[mm]

[mm]

15
15
15
15
18
18
18
18

105
105
115
140
120
130
135
155

100
100
110
135
115
125
130
150

15
15
25
50
15
25
30
50

044920

510934
044921

044922

044923

044924

510935
044925

Width across
nut (hexagon
socket)

Sales unit

[mm]

[pcs]

6
6
6
6
8
8
8
8

25
25
25
25
20
20
20
20

M 10
M 10
M 10
M 10
M 12
M 12
M 12
M 12

TECHNICAL DATA
High performance anchor FH II-H with cap nut

2
do

Min. drill
hole depth for
through fixings
h2

t fix

ETA

ICC

[mm]

[mm]

[mm]

[mm]

10
10
10
12
12
12
15
15
15
18
18

65
80
105
90
105
130
100
115
140
130
155

75
90
115
100
115
140
115
130
155
145
170

10
25
50
10
25
50
10
25
50
25
50

Art.-No.
gvz

Item

FH II 10/10 H
FH II 10/25 H
FH II 10/50 H
FH II 12/10 H
FH II 12/25 H
FH II 12/50 H
FH II 15/10 H
FH II 15/25 H
FH II 15/50 H
FH II 18/25 H
FH II 18/50 H

503139
503140
503141
044905
044906
044907
044908
044909
044910
044915
044916

Drill hole
diameter

Approval

zinc-plated
steel

Items to order only

Anchor
length

Max. fixture
thickness

Thread

Width across
nut

Sales unit

SW

M6
M6
M6
M8
M8
M8
M 10
M 10
M 10
M 12
M 12

[mm]

[pcs]

13
13
13
17
17
17
17
17
17
19
19

50
50
50
50
50
25
25
25
25
20
20

TECHNICAL DATA
high performance

Hex. drive setting tool


(included)

Items to order only

Item

FH II-I 12/M6
FH II-I 12/M8
FH II-I 15/M10
FH II-I 15/M12

12

Zinc-plated
steel

Stainless
steel

Art.-No.
gvz

Art.-No
A4

520358
520359
519014
519015

520360
520361
519018
519019

Approval

anchor FH II-I

ETA

Drill hole
diameter
do
[mm]

12
12
15
15

Min. drill depth Effective


pre-positioned anchorage
installation
depth
h2
hef
[mm]

85
85
85
85

- > [mm]
67
67
76
76

Total
length

Thread

Gap

Installation
torque

Sales
unit

Tinst

[mm]

[mm]

[mm]

[Nm]

[pcs]

78
78
90
90

M6
M8
M10
M12

3-5
3-5
3-5
3-5

15
15
25
25

25
25
25
20

FH II High performance anchor


TECHNICAL DATA

Item

FH II 10/10 B
FH II 10/25 B
FH II 10/50 B
FH II 12/10 B
FH II 12/25 B
FH II 12/50 B
FH II 12/100 B
FH II 15/10 B
FH II 15/25 B
FH II 15/50 B
FH II 15/100 B
FH II 18/25 B
FH II 18/50 B
FH II 18/100 B
FH II 24/25 B
FH II 24/50 B
FH II 24/100 B
FH II 28/30 B
FH II 28/60 B
FH II 28/100 B
FH II 32/30 B
FH II 32/60 B

zinc-plated
steel

Drill hole
diameter

Approval

Items to order only

do

Min. drillAnchor length


hole depth for
through fixings
h2
l

Max. fixture
thickness

Thread

t fix

Art.-No.
gvz

ETA

ICC

[mm]

[mm]

[mm]

[mm]

503142
503143
503144
048773
048774
048775
046832
048776
048777
048778
046835
048779
048780
046841
048886
048887
046842
047547
047548
506630 1)
047549
047550

10
10
10
12
12
12
12
15
15
15
15
18
18
18
24
24
24
28
28
28
32
32

65
80
105
90
105
130
180
100
115
140
190
130
155
205
150
175
225
185
215
255
210
240

70
85
110
95
110
135
185
110
125
150
200
140
165
215
167
192
242
199
229
271
253
283

10
25
50
10
25
50
100
10
25
50
100
25
50
100
25
50
100
30
60
100
30
60

Width across
nut

Sales unit

SW

M6
M6
M6
M8
M8
M8
M8
M 10
M 10
M 10
M 10
M 12
M 12
M 12
M 16
M 16
M 16
M 20
M 20
M 20
M 24
M 24

[mm]

[pcs]

10
10
10
13
13
13
13
17
17
17
17
19
19
19
24
24
24
30
30
30
36
36

50
50
50
50
50
25
25
25
25
25
20
20
20
10
10
10
5
4
4
4
4
4

High performance steel anchors

High performance anchor FH II-B with


hexagon nut and threaded bolt

1) Delivery time on request.

LOADS
High performance anchor FH II - S / FH II - SK
Highest permissible loads for a single anchor1) in concrete C20/254)
For the design the complete approval ETA - 07/0025 has to be considered.
Type

FH II 10 S
FH II 12 S / SK
FH II 15 S / SK
FH II 18 S / SK
FH II 24 S
FH II 28 S
FH II 32 S

Cracked concrete
Effective
Min.
Installation Permissible Permissible
Min.
anchorage member
torque tensile load shear load spacing
depth
thickness
hef
hmin
Tinst
Nperm3)
Vperm3)
smin2)

Min.
edge
distance
cmin2)

[mm]

[mm]

[Nm]

[kN]

[kN]

[mm]

[mm]

[kN]

[kN]

[mm]

[mm]

40
60
70
80
100
125
150

80
120
140
160
200
250
300

10,0
22,5
40,0
80,0
160,0
180,0
200,0

3,6
5,7
7,6
11,9
17,1
24,0
31,5

4,3
15,9
20,1
24,5
34,3
47,9
63,0

40
50
60
70
80
100
120

40
50
60
70
80
100
120

6,1
11,2
14,1
17,2
24,0
33,6
44,2

6,1
18,9
28,2
34,4
48,1
67,2
88,4

40
60
70
80
100
120
160

40
60
70
80
100
120
180

The partial safety factors for material resistance as regulated in the approval as well as a partial
safety factor for load actions of L = 1,4 are considered. As an single anchor counts e.g. an anchor with a spacing s 3 x hef and an edge distance c 1,5 x hef. Accurate data see approval.
2)
Minimum possible axial spacings resp. edge distance while reducing the permissible load.
1)

Non-cracked concrete
Min.
Permissible Permissible
Min.
edge
tensile load shear load spacing
distance
cmin2)
Nperm3)
Vperm3)
smin2)

For combinations of tensile loads, shear loads, bending moments as well as reduced edge
distances or spacings (anchor groups) see approval.
4)
For higher concrete strength classes up to C50/60 higher permissible loads may be possible.
3)

13

FH II High performance anchor


High performance steel anchors

LOADS
High performance anchor FH II - S A4
Highest permissible loads for a single anchor1) in concrete C20/254)
For the design the complete approval ETA - 07/0025 has to be considered.
Type

FH II 10 S A4
FH II 12 S A4 / SK A4
FH II 15 S A4 / SK A4
FH II 18 S A4 / SK A4
FH II 24 S A4

Cracked concrete
Effective
Min.
Installation permissible permissible
min.
anchorage member
torque
tensile
shear
spacing
depth
thickness
load
load
hef
hmin
Tinst
Nperm3)
Vperm3)
smin2)

Non-cracked concrete
min.
permissible permissible
min.
edge
tensile
shear
spacing
distance
load
load
cmin2)
Nperm3)
Vperm3)
smin2)

min.
edge
distance
cmin2)

[mm]

[mm]

[Nm]

[kN]

[kN]

[mm]

[mm]

[kN]

[kN]

[mm]

[mm]

40
60
70
80
100

80
120
140
160
200

15,0
25,0
40,0
100,0
160,0

3,6
5,7
7,6
11,9
17,1

4,3
15,9
20,1
24,5
34,3

40
50
60
70
80

40
50
60
70
80

6,1
9,5
14,1
17,2
24,0

6,1
16,0
24,6
34,4
48,1

40
60
70
80
100

40
60
70
80
100

The partial safety factors for material resistance as regulated in the approval as well as a partial
safety factor for load actions of L = 1,4 are considered. As an single anchor counts e.g. an anchor with a spacing s 3 x hef and an edge distance c 1,5 x hef. Accurate data see approval.
2)
Minimum possible axial spacings resp. edge distance while reducing the permissible load.
1)

For combinations of tensile loads, shear loads, bending moments as well as reduced edge
distances or spacings (anchor groups) see approval.
4)
For higher concrete strength classes up to C50/60 higher permissible loads may be possible.
3)

LOADS
High performance anchor FH II - H
Highest permissible loads for a single anchor1) in concrete C20/254)
For the design the complete approval ETA - 07/0025 has to be considered.

Type

Cracked concrete
Effective
Min.
Installation Permissible Permissible
Min.
anchorage member
torque tensile load shear load spacing
depth
thickness
hef
hmin
Tinst
Nperm3)
Vperm3)
smin2)

Non-cracked concrete
Min.
Permissible Permissible
Min.
edge
tensile load shear load spacing
distance
cmin2)
Nperm3)
Vperm3)
smin2)

Min. edge
distance
cmin2)

[mm]

[mm]

[Nm]

[kN]

[kN]

[mm]

[mm]

[kN]

[kN]

[mm]

[mm]

FH II 10 H

40

80

10,0

3,6

4,3

40

40

6,1

6,1

40

40

FH II 12 H

60

120

22,5

5,7

15,4

50

50

11,2

15,4

60

60

FH II 15 H

70

140

40,0

7,6

20,1

60

60

14,1

23,4

70

70

FH II 18 H

80

160

80,0

11,9

24,5

70

70

17,2

34,4

80

80

The partial safety factors for material resistance as regulated in the approval as well as a partial
safety factor for load actions of L = 1,4 are considered. As an single anchor counts e.g. an anchor with a spacing s 3 x hef and an edge distance c 1,5 x hef. Accurate data see approval.
2)
Minimum possible axial spacings resp. edge distance while reducing the permissible load.
1)

For combinations of tensile loads, shear loads, bending moments as well as reduced edge
distances or spacings (anchor groups) see approval.
4)
For higher concrete strength classes up to C50/60 higher permissible loads may be possible.
3)

LOADS
High performance anchor FH II-I
Highest permissible loads for a single anchor1) in concrete C20/254)
For the design the complete approval ETA - 07/0025 has to be considered..
Type

FH II-I 12/M6
FH II-I 12/M8
FH II-I 15/M10
FH II-I 15/M12

Cracked concrete
Effective
Min.
Installation permissible permissible
min.
anchorage fixture
torque
tensile
shear
spacing
depth
thickness
load
load
hef
hmin
Tinst
Nzul3)
Vzul3)
smin2)

14

min.
edge
distance
cmin2)

[mm]

[mm]

[Nm]

[kN]

[kN]

[mm]

[mm]

[kN]

[kN]

[mm]

[mm]

60
60
70
70

125
125
150
150

15,0
15,0
25,0
25,0

4,3
4,3 / 5,75)
5,7 / 7,65)
5,7 / 7,65)

4,3
8,0
12,4
13,7

50
50
60
60

50
50
60
60

7,1
11,2
14,1
14,1

4,3
8,0
12,4
13,7

60
60
70
70

60
60
70
70

The required partial safety factors of resistance as well as the partial safety factor for load
gf = 1,4 are considered.
2)
Minimum possible axial spacings resp. edge distance while reducing the permissible load.
3)
For combinations of tensile loads, shear loads, bending moments as well as reduced edge
distances or spacings (anchor groups) see approval or Design Software COMPUFIX.
1)

Non-cracked concrete
min.
permissible permissible
min.
edge
tensile
shear
spacing
distance
load
load
cmin2)
Nperm3)
Vperm3)
smin2)

4)
5

For higher concrete strength classes up to C50/60 higher permissible loads may be possible.
When the maximum torque Tfix is applied to the attachment, higher load levels can be achieved.

FH II High performance anchor


LOADS

Type

FH II-I 12/M6 (A4)


FH II-I 12/M8 (A4)
FH II-I 15/M10 (A4)
FH II-I 15/M12 (A4)

Cracked concrete
Effective
Min.
Installation permissible permissible
min.
anchorage fixture
torque
tensile
shear
spacing
depth
thickness
load
load
hef
hmin
Tinst
Nzul3)
Vzul3)
smin2)

Non-cracked concrete
min.
permissible permissible
min.
edge
tensile
shear
spacing
distance
load
load
cmin2)
Nperm3)
Vperm3)
smin2)

min.
edge
distance
cmin2)

[mm]

[mm]

[Nm]

[kN]

[kN]

[mm]

[mm]

[kN]

[kN]

[mm]

[mm]

60
60
70
70

125
125
150
150

15,0
15,0
25,0
25,0

4,3
4,3 / 5,76)
5,7 / 7,66)
5,7 / 7,66)

4,3
8,0
12,4
12,6

50
50
60
60

50
50
60
60

7,1
11,2
14,1
14,1

4,3
8,0
12,4
12,6

60
60
70
70

60
60
70
70

The partial safety factors for material resistance as regulated in the approval as well as a partial
safety factor for load gf = 1,4 are considered.
2)
Minimum possible axial spacings resp. edge distance while reducing the permissible load.

1)

For combinations of tensile loads, shear loads, bending moments as well as reduced edge
distances or spacings (anchor groups) see approval.
4)
For higher concrete strength classes up to C50/60 higher permissible loads may be possible.
3)

LOADS
High performance anchor FH II - B
Highest permissible loads for a single anchor1) in concrete C20/254)
For the design the complete approval ETA - 07/0025 has to be considered.
Type

Cracked concrete
Effective
Min.
Installation Permissible Permissible
Min.
anchorage member
torque tensile load shear load spacing
depth
thickness
hef
hmin
Tinst
Nperm3)
Vperm3)
smin2)
[mm]

[mm]

[Nm]

[kN]

[kN]

[mm]

[mm]

[kN]

Min. edge
distance

cmin2)

[kN]

[mm]

[mm]

FH II 10 B

40

80

10,0

3,6

4,3

40

40

6,1

6,1

40

40

FH II 12 B

60

120

17,5

5,7

15,4

50

50

11,2

15,4

60

60

FH II 15 B

70

140

38,0

7,6

20,1

60

60

14,1

23,4

70

70

FH II 18 B

80

160

80,0

11,9

24,5

70

70

17,2

34,4

80

80

FH II 24 B

100

200

120,0

17,1

34,3

80

80

24,0

48,1

100

100

FH II 28 B

125

250

180,0

24,0

47,9

100

100

33,6

67,2

120

120

FH II 32 B

150

300

200,0

31,5

63,0

120

120

44,2

88,4

160

180

The partial safety factors for material resistance as regulated in the approval as well as a partial
safety factor for load actions of L = 1,4 are considered. As an single anchor counts e.g. an
anchor with a spacing s 3 x hef and an edge distance c 1,5 x hef. Accurate data see approval.
2)
Minimum possible axial spacings resp. edge distance while reducing the permissible load.

1)

Non-cracked concrete
Min.
Permissible Permissible
Min.
edge
tensile load shear load spacing
distance
cmin2)
Nperm3)
Vperm3)
smin2)

High performance steel anchors

High performance anchor FH II-I (A4)


Highest permissible loads for a single anchor1) in concrete C20/254)
For the design the complete approval ETA - 07/0025 has to be considered.

For combinations of tensile loads, shear loads, bending moments as well as reduced edge
distances or spacings (anchor groups) see approval.
4)
For higher concrete strength classes up to C50/60 higher permissible loads may be possible.
3)

15

FZA / FZA-D / FZA-I ZYKON undercut anchor

High performance steel anchors

The fixing system with the highest safety in cracked concrete

Installations in tunnels

VERSIONS

APPROVALS

zinc-plated steel
stainless steel
highly corrosion-resistant steel - type
FZA / FZA-D only

BUILDING MATERIALS

FZA

FZA-D

FZA-I

Approved for:
Concrete C20/25 to C50/60,
cracked and non-cracked
Also suitable for:
Concrete C12/15
Natural stone with dense structure

ADVANTAGES

APPLICATIONS

FUNCTIONING

This anchor uses the distinct ZYKON


undercut technology to provide a
positive fit and ensures maximum
safety, even in large cracks.
Because of the virtually expansion
free installation small edge distances
and axial spacing can be achieved.
The FZA-D combination of threaded
bolts and sleeve permits high shear
load and therefore fewer fixing points.
The FZA-I can be used for surface
flush removal and reuse of the fixing
point which makes installations very
flexible.
The special FZUB drill bit creates the
undercut shape without having to
change tools.
The drill hole geometry is achieved with
a low setting force so the overal energy
required for installation is reduced.

Steel constructions
Guard rails
Consoles
Ladders
Cable conduits
Machines
Staircases
Gates
Faades

The FZA is suitable for pre-positioned


installation, whereas the FZA-D is
suitable for push-through installation.
The FZA-I with internal thread is
suitable for pre-positioned installation.
The undercut drill hole is created using
the special FZUB drill bit.
Once the anchor has been placed in
the drill hole, the expansion sleeve is
driven over the cone using the FZE Plus
setting tool, and the undercut drill hole
is filled with a positive fit.

INSTALLATION - FZA / FZA-D

INSTALLATION - FZA-I

16

Steel girders

FZA / FZA-D / FZA-I ZYKON undercut anchor


TECHNICAL DATA

Item

FZA 10 x 40 M6/10
FZA 10 x 40 M6/35
FZA 12 x 40 M 8/15
FZA 12 x 50 M 8/15
FZA 12 x 50 M 8/50
FZA 14 x 40 M10/25
FZA 14 x 40 M10/25
FZA 14 x 60 M10/25
FZA 14 x 60 M10/50
FZA 18 x 80 M12/25
FZA 18 x 80 M12/55
FZA 22 x 100 M16/25
FZA 22 x 100 M16/30
FZA 22 x 100 M16/60
FZA 22 x 125 M16/60

zinc-plated stainless
steel
steel

Art.-No.
gvz

Art.-No.
A4

highly
corrosion
resistant
steel
Art.-No.
C

060712

060715
060716

060718

060719

060721

060724
060725

060772

060775
060776
060774

060778
060779
060766
060781
060767

060782
060768

096214 1)
096361 1)
096215 1)
096227 1)
096362 1)

096228 1)
096216 1)
096358 1)
096315 1)
096359 1)
033800 1)
024523 1)
096364 1)
096360 1)

Required
drill bit
FZUB

Approval

Items to order only

Required
setting tool
FZE plus

ETA

10 x 40
10 x 40
12 x 40
12 x 50
12 x 50
14 x 40
14 x 40
14 x 60
14 x 60
18 x 80
18 x 80
22 x 100
22 x 100
22 x 100
22 x 125

Bolt
length

Max. fixture
thickness

Thread
M

t fix

[mm]

[mm]

60
85
69
79
114
79
79
102
126
126
156
151
156
184
209

10
35
15
15
50
25
25
25
50
25
55
25
30
60
60

FZE 10 plus
FZE 10 plus
FZE 12 plus
FZE 12 plus
FZE 12 plus
FZE 14 plus
FZE 14 plus
FZE 14 plus
FZE 14 plus
FZE 18 plus
FZE 18 plus
FZE 22 plus
FZE 22 plus
FZE 22 plus
FZE 22 plus

Width
across nut

Sales unit

SW

M6
M6
M8
M8
M8
M 10
M 10
M 10
M 10
M 12
M 12
M 16
M 16
M 16
M 16

[mm]

[pcs]

10
10
13
13
13
17
17
17
17
19
19
24
24
24
24

25
25
25
20
20
25
20
10
10
10
10
10
10
10
6

High performance steel anchors

ZYKON Bolt anchor FZA

1) Delivery time on request.

TECHNICAL DATA

ZYKON Through anchor FZA-D

Item

FZA 12 x 50 M 8 D/10
FZA 12 x 50 M 8 D/10
FZA 12 x 60 M 8 D/10
FZA 12 x 80 M 8 D/30
FZA 12 x 80 M 8 D/30
FZA 14 x 80 M10 D/20
FZA 14 x 100 M 8 D/30
FZA 18 x 100 M12 D/20
FZA 18 x 130 M12 D/50
FZA 22 x 125 M16 D/25
1) Delivery time on request.

Required
drill bit
FZUB

zinc-plated
steel

stainless
steel

highly
corrosion
resistant
steel

Art.-No.
gvz

Art.-No.
A4

Art.-No.
C

ETA

060664

060665
060666

060669
060670
060672
060673
060675

096319 1)

096354 1)
096355 1)

096356 1)
096357 1)

060652

060653
060654

060657
060658
060684
060685
060663

Approval

Items to order only

12 x 50
12 x 50
12 x 60
12 x 80
12 x 80
14 x 80
14 x 100
18 x 100
18 x 130
22 x 125

Required
setting tool
FZE plus

FZE 12 plus
FZE 12 plus
FZE 12 plus
FZE 12 plus
FZE 12 plus
FZE 14 plus
FZE 14 plus
FZE 18 plus
FZE 18 plus
FZE 22 plus

Bolt length Max. fixture


thickness

Thread

Width
across nut
SW
[mm]

[pcs]

13
13
13
13
13
17
17
19
19
24

25
20
25
25
20
10
10
10
10
10

l
[mm]

t fix
[mm]

69
69
79
99
99
102
126
126
156
156

10
10
10
30
30
20
40
20
50
25

M8
M8
M8
M8
M8
M 10
M 10
M 12
M 12
M 16

Sales unit

17

FZA / FZA-D / FZA-I ZYKON undercut anchor

ZYKON Internally-threaded anchor FZA-I

Items to order only

Item

FZA 12 x 40 M6 I
FZA 12 x 50 M6 I
FZA 14 x 60 M8 I
FZA 18 x 80 M10 I
FZA 22 x 100 M12 I
FZA 22 x 125 M12 I

zinc-plated
steel

stainless
steel

Approval

High performance steel anchors

TECHNICAL DATA

Art.-No.
gvz

Art.-No.
A4

ETA

060758

060760
060761
060763
060769

060783
060784
060786
060787
060788
060770

Required
drill bit FZUB

Required setting
tool FZE plus

Internal thread
M

12 x 40
12 x 50
14 x 60
18 x 80
22 x 100
22 x 125

FZE 12 plus
FZE 12 plus
FZE 14 plus
FZE 18 plus
FZE 22 plus
FZE 22 plus

M6
M6
M8
M 10
M 12
M 12

Min. bolt
penetration
lE,min
[mm]

Max. bolt
penetration
lE,max
[mm]

Sales unit

8
8
11
13
15
15

13
13
17
21
25
25

25
25
20
10
10
10

[pcs]

ACCESSORIES
Drill bit FZUB

Fits anchor

Items to order only


Item

FZUB 10 x 40
FZUB 12 x 40
FZUB 12 x 50
FZUB 12 x 60
FZUB 12 x 80
FZUB 14 x 40
FZUB 14 x 60
FZUB 14 x 80
FZUB 14 x 100
FZUB 18 x 80
FZUB 18 x 100
FZUB 18 x 130
FZUB 22 x 100
FZUB 22 x 125

Sales unit

Art.-No.

bolt anchor

push-through anchor

internal thread anchor

[pcs]

060622
060623
060627
060625
060626
060624
060628
060629
060630
060634
060632
060633
060636
060638

FZA 10 x 40 M6
FZA 12 x 40 M8
FZA 12 x 50 M8
FZA 14 x 40 M10
FZA 14 x 60 M10
FZA 18 x 80 M12
FZA 22 x 100 M16
FZA 22 x 125 M16

FZA 12 x 50 M8 D/10
FZA 12 x 60 M8 D/10
FZA 12 x 80 M8 D/30
FZA 14 x 80 M10 D/20
FZA 14 x 100 M10 D/40
FZA 18 x 100 M12 D/20
FZA 18 x 130 M12 D/50
FZA 22 x 125 M16 D/25

FZA 12 x 40 M6 I
FZA 12 x 50 M6 I
FZA 14 x 60 M8 I
FZA 18 x 80 M10I
FZA 22 x 100 M12 I
FZA 22 x 125 M12 I

1
1
1
1
1
1
1
1
1
1
1
1
1
1

ACCESSORIES

Setting tool FZE plus

Fits anchor

Items to order only


Item

FZE 10 plus
FZE 12 plus
FZE 14 plus
FZE 18 plus
FZE 22 plus
1) Without centring pin.

18

Sales unit

Art.-No.

bolt anchor

push-through anchor

internal thread anchor

[pcs]

044637 1)
044638
044639
044640
044641

FZA 10 x ... M6
FZA 12 x ... M8
FZA 14 x ... M10
FZA 18 x ... M12
FZA 22 x ... M16

FZA 12 x ... M8 D
FZA 14 x ... M10 D
FZA 18 x ... M12 D
FZA 22 x ... M16 D

FZA 12 x ... M6 I
FZA 14 x ... M8 I
FZA 18 x ... M10 I
FZA 22 x ... M12 I

1
1
1
1
1

FZA / FZA-D / FZA-I ZYKON undercut anchor


LOADS

Cracked concrete
Type

FZA 10 x 40 M6
FZA 12 x 40 M8
FZA 14 x 40 M10
FZA 12 x 50 M8
FZA 14 x 60 M10
FZA 18 x 80 M12
FZA 22 x 100 M16
FZA 22 x 125 M16

Effective
Min.
Installation Permissible Permissible
anchorage member
torque tensile load shear load
depth
thickness
hmin
Tinst
Nperm3)
Vperm3)
hef

Min.
spacing

Non-cracked concrete

smin2)

Min.
edge
distance
cmin2)

Permissible Permissible
tensile load shear load

Min.
spacing

Nperm3)

Vperm3)

smin2)

Min.
edge
distance
cmin2)

[mm]

[mm]

[Nm]

[kN]

[kN]

[mm]

[mm]

[kN]

[kN]

[mm]

[mm]

40
40
40
50
60
80
100
125

100
100
100
110
130
160
200
250

8,5
20,0
40,0
20,0
40,0
60,0
100,0
100,0

2,4
2,4
2,4
4,3
5,7
9,5
17,1
19,0

4,6
5,6
5,6
7,9
13,3
19,3
34,3
35,9

40
40
70
50
60
80
100
125

35
40
70
45
55
70
100
125

3,6
3,6
3,6
5,7
9,5
14,3
19,0
19,0

4,6
7,9
7,9
8,4
13,3
19,3
35,9
35,9

40
40
70
50
60
80
100
125

35
40
70
45
55
70
100
125

LOADS
ZYKON undercut anchor FZA A4
Highest permissible loads for a single anchor1) in concrete C20/254)
For the design the complete approval ETA - 98/0004 has to be considered.
Type

FZA 10 x 40 M6 A4
FZA 12 x 40 M8 A4
FZA 14 x 40 M10 A4
FZA 12 x 50 M8 A4
FZA 14 x 60 M10 A4
FZA 18 x 80 M12 A4
FZA 22 x 100 M16 A4
FZA 22 x 125 M16 A4

Cracked concrete
Effective
Min.
Installation Permissible Permissible
Min.
anchorage member
torque
tensile load shear load spacing
depth
thickness
hef
hmin
Tinst
Nperm3)
Vperm3)
smin2)

Min.
edge
distance
cmin2)

Non-cracked concrete
Permissible Permissible
Min.
tensile load shear load spacing
Nperm3)

Vperm3)

smin2)

Min.
edge
distance
cmin2)

[mm]

[mm]

[Nm]

[kN]

[kN]

[mm]

[mm]

[kN]

[kN]

[mm]

[mm]

40
40
40
50
60
80
100
125

100
100
100
110
130
160
200
250

8,5
20,0
40,0
20,0
40,0
60,0
100,0
100,0

2,4
2,4
2,4
4,3
5,7
9,5
17,1
19,0

3,2
5,6
5,6
5,9
9,3
13,5
25,2
25,2

40
40
70
50
60
80
100
125

35
40
70
45
55
70
100
125

3,6
3,6
3,6
5,7
9,5
14,3
19,0
19,0

3,2
5,9
7,9
5,9
9,3
13,5
25,2
25,2

40
40
70
50
60
80
100
125

35
40
70
45
55
70
100
125

High performance steel anchors

ZYKON undercut anchor FZA


Highest permissible loads for a single anchor1) in concrete C20/254)
For the design the complete approval ETA - 98/0004 has to be considered.

LOADS
ZYKON undercut anchor FZA-D
Highest permissible loads for a single anchor1) in concrete C20/254)
For the design the complete approval ETA - 98/0004 has to be considered.
Type

FZA 12 x 50 M8 D
FZA 12 x 60 M8 D
FZA 12 x 80 M8 D
FZA 14 x 80 M10 D
FZA 14 x 100 M10 D
FZA 18 x 100 M12 D
FZA 18 x 130 M12 D
FZA 22 x 125 M16 D

Cracked concrete
Effective
Min.
Installation Permissible Permissible
Min.
anchorage member
torque tensile load shear load spacing
depth
thickness
hef
hmin
Tinst
Nperm3)
Vperm3)
smin2)

Min.
edge
distance
cmin2)

Non-cracked concrete
Permissible Permissible
Min.
tensile load shear load spacing
Nperm3)

Vperm3)

smin2)

Min.
edge
distance
cmin2)

[mm]

[mm]

[Nm]

[kN]

[kN]

[mm]

[mm]

[kN]

[kN]

[mm]

[mm]

40
50
50
60
60
80
80
100

100
110
110
130
130
160
160
200

20,0
20,0
20,0
40,0
40,0
60,0
100,0
100,0

2,4
4,3
4,3
5,7
5,7
9,5
9,5
17,1

5,6
7,9
7,9
13,3
13,3
19,3
19,3
34,3

40
50
50
60
60
80
80
100

35
45
45
55
55
70
70
100

3,6
5,7
5,7
9,5
9,5
14,3
14,3
19,0

7,9
8,4
8,4
13,3
13,3
19,3
19,3
35,9

40
50
50
60
60
80
80
100

35
45
45
55
55
70
70
100

19

FZA / FZA-D / FZA-I ZYKON undercut anchor

High performance steel anchors

LOADS
ZYKON undercut anchor FZA-D A4
Highest permissible loads for a single anchor1) in concrete C20/254)
For the design the complete approval ETA - 98/0004 has to be considered.
Type

FZA 12 x 50 M8 D A4
FZA 12 x 60 M8 D A4
FZA 12 x 80 M8 D A4
FZA 14 x 80 M10 D A4
FZA 14 x 100 M10 D A4
FZA 18 x 100 M12 D A4
FZA 18 x 130 M12 D A4
FZA 22 x 125 M16 D A4

Cracked concrete
Effective
Min.
Installation Permissible Permissible
Min.
anchorage member
torque tensile load shear load spacing
depth
thickness
hef
hmin
Tinst
Nperm3)
Vperm3)
smin2)

Non-cracked concrete
Min.
Permissible Permissible
Min.
edge
tensile load shear load spacing
distance
cmin2)
Nperm3)
Vperm3)
smin2)

Min.
edge
distance
cmin2)

[mm]

[mm]

[Nm]

[kN]

[kN]

[mm]

[mm]

[kN]

[kN]

[mm]

[mm]

40
50
50
60
60
80
80
100

100
110
110
130
130
160
160
200

20,0
20,0
20,0
40,0
40,0
60,0
60,0
100,0

2,4
4,3
4,3
5,7
5,7
9,5
9,5
17,1

5,6
5,9
5,9
9,3
9,3
13,5
13,5
25,2

40
50
50
60
60
80
80
100

35
45
45
55
55
70
70
100

3,6
5,7
5,7
9,5
9,5
14,3
14,3
19,0

5,9
5,9
5,9
9,3
9,3
13,5
13,5
25,2

40
50
50
60
60
80
80
100

35
45
45
55
55
70
70
100

LOADS
ZYKON undercut anchor FZA-I (screw quality 8.8)
Highest permissible loads for a single anchor1) in concrete C20/254)
For the design the complete approval ETA - 98/0004 has to be considered.
Type

FZA 12 x 40 M6 I
FZA 12 x 50 M6 I
FZA 14 x 60 M8 I
FZA 18 x 80 M10 I
FZA 22 x 100 M12 I
FZA 22 x 125 M12 I

Cracked concrete
Effective
Min.
Installation Permissible Permissible
Min.
anchorage member
torque tensile load shear load spacing
depth
thickness
hef
hmin
Tinst
Nzul3)
Vzul3)
smin2)

Non-cracked concrete
Min.
Permissible Permissible
Min.
edge
tensile load shear load spacing
distance
cmin2)
Nzul3)
Vzul3)
smin2)

Min.
edge
distance
cmin2)

[mm]

[mm]

[Nm]

[kN]

[kN]

[mm]

[mm]

[kN]

[kN]

[mm]

[mm]

40
50
60
80
100
125

100
110
130
160
200
250

8,5
8,5
15,0
30,0
60,0
60,0

2,4
4,3
5,7
9,5
17,1
19,0

4,1
4,1
5,4
5,6
13,2
13,2

40
50
60
80
100
125

35
45
55
70
100
125

3,6
5,7
9,5
9,6
19,0
19,0

4,1
4,1
5,4
5,6
13,2
13,2

40
50
60
80
100
125

35
45
55
70
100
125

LOADS
ZYKON undercut anchor FZA-I A4 (screw quality A4-70)
Highest permissible loads for a single anchor1) in concrete C20/254)
For the design the complete approval ETA - 98/0004 has to be considered.
Type

FZA 12 x 40 M6 I A4
FZA 12 x 50 M6 I A4
FZA 14 x 60 M8 I A4
FZA 18 x 80 M10 I A4
FZA 22 x 100 M12 I A4
FZA 22 x 125 M12 I A4

Cracked concrete
Effective
Min.
Installation Permissible Permissible
Min.
anchorage member
torque tensile load shear load spacing
depth
thickness
hef
hmin
Tinst
Nperm3)
Vperm3)
smin2)

20

Min.
edge
distance
cmin2)

[mm]

[mm]

[Nm]

[kN]

[kN]

[mm]

[mm]

[kN]

[kN]

[mm]

[mm]

40
50
60
80
100
125

100
110
130
160
200
250

8,5
8,5
15,0
30,0
60,0
60,0

2,4
4,3
5,7
9,0
17,1
19,0

3,2
3,2
4,3
5,4
12,7
12,7

40
50
60
80
100
125

35
45
55
70
100
125

3,6
5,4
7,1
9,0
19,0
19,0

3,2
3,2
4,3
5,4
12,7
12,7

40
50
60
80
100
125

35
45
55
70
100
125

The partial safety factors for material resistance as regulated in the approval as well as a partial
safety factor for load actions of L = 1,4 are considered. As an single anchor counts e.g. an anchor with a spacing s 3 x hef and an edge distance c 1,5 x hef. Accurate data see approval.
2)
Minimum possible axial spacings resp. edge distance while reducing the permissible load.
1)

Non-cracked concrete
Min.
Permissible Permissible
Min.
edge
tensile load shear load spacing
distance
cmin2)
Nperm3)
Vperm3)
smin2)

For combinations of tensile loads, shear loads, bending moments as well as reduced edge
distances or spacings (anchor groups) see approval.
4)
For higher concrete strength classes up to C50/60 higher permissible loads may be possible.
3)

FZEA II ZYKON hammerset anchor

Anchor shape
before expansion

Anchor shape
after correct

Emergency exit signs in tunnels

Air conditioning units

VERSIONS

APPROVALS

zinc-plated steel
stainless steel
highly corrosion-resistant steel

BUILDING MATERIALS

The anchor is set correctly when the


anchor sleeve is positioned flush with the
surface of the concrete and the 4 imprints
are visible

Approved for:
Concrete C20/25 to C50/60,
cracked and non-cracked
Also suitable for:
Concrete C12/15
Natural stone with dense structure

High performance steel anchors

The internally threaded anchor with shallow anchoring depth


for individual fixings in cracked concrete

ADVANTAGES

APPLICATIONS

FUNCTIONING

The combination of hammerset and


ZYKON undercut anchor allows for
individual fixings in cracked concrete.
The
special
ZYKON
undercut
technology reduces the energy
required for installation.
The special FZUB drill bit creates the
undercut shape without having to
change tools.
The embossing that is applied when
expanding the anchor secures the
simple control of the anchoring.
The drill hole geometry is achieved
with a low setting force so the overall
energy required for installation is
reduced.

Pipes
Ventilation systems
Sprinkler systems
Cable conduits
Suspended ceilings

The FZEA II is suitable for


pre-positioned installation.
The undercut drill hole is created using
the special FZUB drill bit
Once the anchor has been placed in
the drill hole, the expansion sleeve is
expanded and splayed open by driving
in the internal expansion pin with the
FZED Plus setting tool. The undercut
drill hole is now filled with a positive fit.

INSTALLATION

21

FZEA II ZYKON hammerset anchor

Zykon-Hammerset anchor FZEA II

Items to order only

Item

FZEA II 10 x 40 M 8
FZEA II 12 x 40 M10
FZEA II 14 x 40 M12

Art.-No.
gvz

stainless
steel

Art.-No.
A4

047303 047306
047304 047307
047305 047308

highly
corrosion
resistant
steel
Art.-No.
C

047309
047310
047311

Required drill Required setting


bit FZUB
tool FZED plus

ETA

Length

Internal
thread

Max. bolt Min. bolt Sales unit


penetration penetration

[mm]

10 x 40
12 x 40
14 x 40

FZED 10 plus
FZED 12 plus
FZED 14 plus

43
43
43

M8
M 10
M 12

lE,max

lE,min

[mm]

[mm]

[pcs]

17
19
21

11
13
15

100
100
50

ACCESSORIES
Drill bit FZUB

Item

Setting tool FZED plus

Fits anchor

Items to Order only

FZUB 10 x 40
FZUB 12 x 40
FZUB 14 x 40
FZED 10 plus
FZED 12 plus
FZED 14 plus

22

zinc-plated
steel

Approval

High performance steel anchors

TECHNICAL DATA

Art.-No.

060622
060623
060624
044642
044643
044644

Sales unit
[pcs]

FZEA II 10 x 40
FZEA II 12 x 40
FZEA II 14 x 40
FZEA II 10 x 40
FZEA II 12 x 40
FZEA II 14 x 40

1
1
1
1
1
1

FZEA II ZYKON hammerset anchor


LOADS

Type

FZEA II 10 x 40 M8
FZEA II 12 x 40 M10
FZEA II 14 x 40 M12

Cracked concrete
Effective
Min.
Installation Permissible Permissible
Min.
anchorage member
torque tensile load shear load spacing
depth
thickness
hef
hmin
Tinst
Nperm3)
Vperm3)
smin2)

Non-cracked concrete
Min.
Permissible Permissible
Min.
edge
tensile load shear load spacing
distance
cmin2)
Nperm3)
Vperm3)
smin2)

Min.
edge
distance
cmin2)

[mm]

[mm]

[Nm]

[kN]

[kN]

[mm]

[mm]

[kN]

[kN]

[mm]

[mm]

40
40
40

80
80
80

10,0
15,0
20,0

1,6
3,0
3,6

4,7
5,6
5,6

40
45
50

40
45
50

3,6
3,6
3,6

4,7
7,8
7,9

40
45
50

40
45
50

The partial safety factors for material resistance as regulated in the approval as well as a partial
safety factor for load actions of L = 1,4 are considered. As an single anchor counts e.g. an anchor with a spacing s 3 x hef and an edge distance c 1,5 x hef. Accurate data see approval.
2)
Minimum possible axial spacings resp. edge distance while reducing the permissible load.
1)

For combinations of tensile loads, shear loads, bending moments as well as reduced edge
distances or spacings (anchor groups) see approval.
4)
For higher concrete strength classes up to C50/60 higher permissible loads may be possible.
3)

LOADS
ZYKON hammerset anchor FZEA II A4 (screw quality A4-70)
Highest permissible loads for a single anchor1) in concrete C20/254)
For the design the complete approval ETA - 06/0271 has to be considered.
Type

FZEA II 10 x 40 M8 A4
FZEA II 12 x 40 M10 A4
FZEA II 14 x 40 M12 A4

Cracked concrete
Effective
Min.
Installation Permissible Permissible Min.
anchorage member
torque
tensile load shear load spacing
depth
thickness
hef
hmin
Tinst
Nperm3)
Vperm3)
smin2)

Non-cracked concrete
Min.
Permissible Permissible
Min.
edge
tensile load shear load spacing
distance
cmin2)
Nperm3)
Vperm3)
smin2)

Min.
edge
distance
cmin2)

[mm]

[mm]

[Nm]

[kN]

[kN]

[mm]

[mm]

[kN]

[kN]

[mm]

[mm]

40
40
40

80
80
80

15,0
20,0
40,0

1,6
3,0
3,6

5,6
5,6
5,6

40
45
50

40
45
50

3,6
3,6
3,6

5,7
7,9
7,9

40
45
50

40
45
50

The partial safety factors for material resistance as regulated in the approval as well as a partial
safety factor for load actions of L = 1,4 are considered. As an single anchor counts e.g. an
anchor with a spacing s 3 x hef and an edge distance c 1,5 x hef. Accurate data see approval.
2)
Minimum possible axial spacings resp. edge distance while reducing the permissible load.
1)

3)

4)

High performance steel anchors

ZYKON hammerset anchor FZEA II (screw quality 5.8)


Highest permissible loads for a single anchor1) in concrete C20/254)
For the design the complete approval ETA - 06/0271 has to be considered.

For combinations of tensile loads, shear loads, bending moments as well as reduced edge
distances or spacings (anchor groups) see approval.
For higher concrete strength classes up to C50/60 higher permissible loads may be possible.

LOADS
ZYKON hammerset anchor FZEA II C (screw quality: material 1.4529, strength 700 N/mm)
Highest permissible loads for a single anchor1) in concrete C20/254)
For the design the complete approval ETA - 06/0271 has to be considered.
Type

FZEA II 10 x 40 M8 C
FZEA II 12 x 40 M10 C
FZEA II 14 x 40 M12 C

Cracked concrete
Effective
Min.
Installation Permissible Permissible
Min.
anchorage member
torque
tensile load shear load spacing
depth
thickness
hef
hmin
Tinst
Nperm3)
Vperm3)
smin2)

Min.
edge
distance
cmin2)

[mm]

[mm]

[Nm]

[kN]

[kN]

[mm]

[mm]

[kN]

[kN]

[mm]

[mm]

40
40
40

80
80
80

15,0
20,0
40,0

1,6
3,0
3,6

5,6
5,6
5,6

40
45
50

40
45
50

3,6
3,6
3,6

5,7
7,9
7,9

40
45
50

40
45
50

The partial safety factors for material resistance as regulated in the approval as well as a partial
safety factor for load actions of L = 1,4 are considered. As an single anchor counts e.g. an
anchor with a spacing s 3 x hef and an edge distance c 1,5 x hef. Accurate data see approval.
2)
Minimum possible axial spacings resp. edge distance while reducing the permissible load.
1)

Non-cracked concrete
Min.
Permissible Permissible
Min.
edge
tensile load shear load spacing
distance
cmin2)
Nperm3)
Vperm3)
smin2)

3)

4)

For combinations of tensile loads, shear loads, bending moments as well as reduced edge
distances or spacings (anchor groups) see approval.
For higher concrete strength classes up to C50/60 higher permissible loads may be possible.

23

FBS Concrete screw


High performance steel anchors

The fully removable fixing in cracked concrete

Protective barriers

VERSIONS

APPROVALS

zinc-plated steel
stainless steel

BUILDING MATERIALS
Approved for:
Concrete C20/25 to C50/60,
cracked and non-cracked
Also suitable for:
Concrete C12/15
Natural stone with dense structure

2
ADVANTAGES

APPLICATIONS

FUNCTIONING

The self-tapping concrete screw


enables full removal and is ideally
suited to temporary fixings.
The FBS can be set and installed in one
go, thereby saving on installation time.
When combined with a tangential
impact wrench, the screw principle
allows for a quick and easy installation.
The head embossing offers a simple
control of the anchoring, thus saving
time.

Guard rails
Consoles
Metal profiles
Ladders
Protection boards
Gates
Faades
Window elements
Temporary fixings

The FBS is suitable for push-through


installation.
When the concrete screw is screwed
into the drill hole, the thread taps into
the concrete with a positive fit.
Please note the power output
information to ensure that the best
results are achieved with a tangential
impact wrench (incl. nuts fitting
tangential impact wrenches) (see
table).
Use FBS A4 for external applications
(including temporary ones) and those
in a damp environment.

INSTALLATION

24

Formwork bracings

FBS Concrete screw


TECHNICAL DATA

zinc-plated stainless
steel
steel

Item to order only

Approval

Concrete screw FBS-S with hexagon head

Drill hole
diameter

Item

FBS 8x70 US
FBS 8x110 US
FBS 8x90 S
FBS 10x90 S
FBS 10x100 S
FBS 10x100 A4 S
FBS 10x120 S

Art.-No.
A4

066956

066957

066958

067062

067063

047465
067168

Screw
length

Max. fixture
thickness

do

h2

ls

t fix

[mm]

[mm]

[mm]

[mm]

8
8
8
10
10
10
10

90
110
100
100
110
110
120

80
100
90
90
100
100
110

5
25
15
5
15
15
25

ETA
Art.-No.
gvz

Min. drill-hole depth


for through fixings

Actuation

Sales
unit

[pcs]

T40/SW13
T40/SW13
SW 16
SW 18
SW 18
SW 17
SW 18

100
100
100
50
50
50
50

Item to order only

Approval

Concrete screw FBS with forged washer

zinc-plated
steel

ETA
Item

Art.-No.
gvz

Drill
Drill hole
Screw
Screw
diameter diameter in diameter
length
object
(under head)

Drill Screw-in Max. Recommended Maximum


depth depth useable nominal torque tightening
length of tangential torque with
impact wrench torque wrench
resp. ratch
h1
hnom

do

df

ds

lu

[mm]

[mm]

[mm]

[mm]

[mm]

High performance steel anchors

Concrete screw FBS-US with hexagon head


and forged washer

Width
across
nut

Sales
unit

[pcs]

[Nm]

[Nm]

SW [mm]

[pcs]

FBS 8x70
FBS 8x80
FBS 8x90
FBS 8x110
FBS 8x130

517875
517876
517877
517878
517880

8
8
8
8
8

12
12
12
12
12

8
8
8
8
8

70
80
90
110
130

75
75
75
75
75

65
65
65
65
65

5
15
25
45
65

250
250
250
250
250

20
20
20
20
20

13
13
13
13
13

50
50
50
50
50

FBS 10x70
FBS 10x90
FBS 10x100
FBS 10x120
FBS 10x140
FBS 10x160
FBS 10x200

517881
517883
517884
517885
517887
517891
517893

10
10
10
10
10
10
10

14
14
14
14
14
14
14

10
10
10
10
10
10
10

70
90
100
120
140
160
200

75
95
95
95
95
95
95

65
85
85
85
85
85
85

5
5
15
35
55
75
115

300
300
300
300
300
300
300

40
40
40
40
40
40
40

15
15
15
15
15
15
15

50
50
50
50
50
50
50

FBS 12x90
FBS 12x110
FBS 12x130
FBS 12x150

517895
517898
517900
517903

12
12
12
12

16
16
16
16

12
12
12
12

90
110
130
150

95
110
110
110

85
100
100
100

5
10
30
50

450
450
450
450

60
60
60
60

17
17
17
17

20
20
20
20

FBS 14x110
FBS 14x135
FBS 14x160

517905
517908
517910

14
14
14

18
18
18

14
14
14

110
135
160

110
135
170

100
125
125

10
10
35

450
450
450

80
80
80

21
21
21

20
8
8

25

FBS Concrete screw


INSTALLATION TORQUE OF CONCRETE SCREWS

High performance steel anchors

Concrete screw

recommended nominal torque


of the tangential impact wrench*)
[Nm]

maximum tightening torque


with torque wrench resp. ratch
[Nm]

200
300

40
40

FBS 8
FBS 10

*) Use nuts (black) which fit percussion power screwdrivers!


The conversion of nominal output into effective tightening torque varies from machine to machine - always therefore use torque control.

LOADS
Concrete screw FBS
Highest permissible loads for a single anchor1) in concrete C20/254)
For the design the complete approval ETA - 11/0095 has to be considered.
Type

FBS 8
FBS 10

Effective
Min.
anchorage member
depth
thickness
hef
hmin

Installation
torque

Cracked concrete
Permissible Permissible
Min.
tensile load shear load
spacing

Tinst

Nperm3)

Vperm3)

smin2)

Min.
edge
distance
cmin2)

Non-cracked concrete
Permissible Permissible
Min.
tensile load shear load
spacing
Nperm3)

Vperm3)

smin2)

Min.
edge
distance
cmin2)

[mm]

[mm]

[Nm]

[kN]

[kN]

[mm]

[mm]

[kN]

[kN]

[mm]

[mm]

51
68

120
130

4,3
7,6

6,2
16,2

50
70

50
70

5,7
13,5

8,6
16,2

50
70

50
70

The partial safety factors for material resistance as regulated in the approval as well as a partial
safety factor for load actions of L = 1,4 are considered. As an single anchor counts e.g. an anchor with a spacing s 3 x hef and an edge distance c 1,5 x hef. Accurate data see approval.
2)
Minimum possible axial spacings resp. edge distance while reducing the permissible load.
1)

For combinations of tensile loads, shear loads, bending moments as well as reduced edge
distances or spacings (anchor groups) see approval.
4)
For higher concrete strength classes up to C50/60 higher permissible loads may be possible.
3)

LOADS
Concrete screw FBS A4
Highest permissible loads for a single anchor1) in concrete C20/254)
For the design the complete approval ETA - 11/0095 has to be considered.
Type

FBS 10 A4

26

Effective
Min.
anchorage member
depth
thickness
hef
hmin

Cracked concrete
Installation Permissible Permissible
Min.
torque
tensile load shear load
spacing
Tinst

Nperm3)

Vperm3)

smin2)

Min.
edge
distance
cmin2)

Permissible
tensile load
Nperm3)

Non-cracked concrete
Permissible
Min.
shear load
spacing
Vperm3)

smin2)

Min.
edge
distance
cmin2)

[mm]

[mm]

[Nm]

[kN]

[kN]

[mm]

[mm]

[kN]

[kN]

[mm]

[mm]

68

130

7,6

19,0

70

70

13,5

19,0

70

70

FBS Concrete screw


The screw solution for multiple fixings

Strip lighting

VERSIONS

APPROVALS

zinc-plated steel

BUILDING MATERIALS
Approved for:
Concrete C20/25 to C50/60,
cracked, for multiple fixings of nonstructural applications
Also suitable for:
Concrete C12/15
Natural stone with dense structure

High performance steel anchors

Ventilation systems

ADVANTAGES

APPLICATIONS

FUNCTIONING

The concrete screw has been approved


for the multiple fixing of non-load
bearing systems and which makes it
ideal for fixing pipelines, cable conduits
etc.
The FBS can be set and installed in one
go, saving valuable installation time.
When combined with a tangential
impact wrench, the screw design
allows for a quick and easy installation.
A range of head shapes allows for the
fixing of wide-ranging attachments,
and for the ideal adaptation to suit the
intended use.

Pipes
Ventilation systems
Sprinkler systems
Cable conduits
Wire hangers
Punched tapes
Ceilings
Temporary internal fixings

The FBS type SK and type P are suitable


for push-through installation; whilst the
FBS type M8 and type M8/M10 I are
suitable for pre-positioned installation.
When the concrete screw is screwed
into the drill hole, the thread taps into
the concrete making a positive fit.
Please note the power output
information to ensure that the best
results are achieved with a tangential
impact wrench (incl. nuts fitting
tangential impact wrenches - see
table).
Head shapes for flexible design
solutions:
Countersunk head - type SK for
surface flush fixings.
Panhead - type P.
Bushing with internal thread - type
M8/M10-I for suspended items.
Threaded bolts - type M8.

INSTALLATION

27

FBS Concrete screw


TECHNICAL DATA

High performance steel anchors

Concrete screw FBS-P, panhead

Items to order only

Item

FBS 5/5 P
FBS 6/5 P
FBS 6/25 P
FBS 6x60 SK

zinc-plated
steel

Approval

Concrete screw FBS-SK, countersunk head

Drill hole
diameter
do

Art.-No.
gvz

ETA

[mm]

5
6
6
6

066774
066939
066948
066935

Drill hole diameter


in object

7
8
8
8

Min. Drill-hole
depth
h2

Anchor
length
l

Max. fixture
thickness
t fix

[mm]

[mm]

[mm]

65
65
85
65

55
60
80
60

5
5
25
5

Width
across nut

Sales unit

[pcs]

T30
T 30
T 30
T 30

100
100
100
100

Width
across nut
SW

Sales
unit

[mm]

[pcs]

10
13

100
100

TECHNICAL DATA
Concrete screw FBS-M8, outside diameter M8
Concrete screw FBS-M8/M10,
internal thread M8/M10

Item

FBS 6x55 M8
FBS 6x55 M8/M10I

zinc-plated
steel
Art.-No.
gvz

066949
066950

Approval

Drill hole
diameter
do

Min. drill hole


depth
h2

Anchor
length
l

Projection
length
l1

ETA

[mm]

[mm]

[mm]

[mm]

6
6

60
60

75
83

19
26

Thread
M

M8
M8 + M10

INSTALLATION TORQUE OF CONCRETE SCREWS


Concrete screw

Recommended nominal torque


of the tangential impact wrench*)
[Nm]

Maximum tightening torque


with torque wrench resp. ratch
[Nm]

150

15

FBS 6

*) Use nuts (black) which fit percussion power screwdrivers!


The conversion of nominal output into effective tightening torque varies from machine to machine - always therefore use torque control.

LOADS
Concrete screw FBS
Highest permissible loads for a single anchor1) for multiple use for non-structural applications in concrete C20/254).
For the design the complete approval ETA - 11/0093 has to be considered.
Typ

FBS 6

Effective Minimum
anchorage member
depth
thickness
hef
hmin

Installation
torque

Cracked concrete
Permissible Permissible
Min.
tensile load shear load spacing

Tinst

Nperm3)

Vperm3)

smin2)

Min.
edge
distance
cmin2)

28

Nperm3)

Vperm3)

smin2)

Min.
edge
distance
cmin2)

[mm]

[mm]

[Nm]

[kN]

[kN]

[mm]

[mm]

[kN]

[kN]

[mm]

[mm]

44

100

3,6

3,3

40

40

3,6

3,3

40

40

The partial safety factors for material resistance as regulated in the approval as well as a partial
safety factor for load actions of L = 1,4 are considered. As an single anchor counts e.g. an anchor with a spacing s 3 x hef and an edge distance c 1,5 x hef. Accurate data see approval.
2)
Minimum possible axial spacings resp. edge distance while reducing the permissible load.
1)

Non-cracked concrete
Permissible
Min.
shear load
spacing

Permissible
tensile load

For combinations of tensile loads, shear loads, bending moments as well as reduced edge
distances or spacings (anchor groups) see approval.
4)
For higher concrete strength classes up to C50/60 higher permissible loads may be possible.
3)

EA II Hammerset anchor

Sprinklers

Pipelines

VERSIONS

APPROVALS

zinc-plated steel
stainless steel

BUILDING MATERIALS
Approved for:
Concrete C20/25 to C50/60,
cracked, for the multiple fixings of
non-load-bearing systems
Concrete C20/25 to C50/60,
non-cracked
Also suitable for:
Concrete C12/15
Natural stone with dense structure

High performance steel anchors

The internally threaded anchor with rim for simple hammerset


installation

ADVANTAGES

APPLICATIONS

FUNCTIONING

The embossed rim prevents the anchor


sleeve from slipping, ensuring a trouble
free hammerset installation.
The metric internal thread means that
it is possible to use standard screws or
threaded rods to suit the intended use.
The EA II S-SDS machine setting
tool allows for effortless installation,
particularly for a series of installations.
The embossing that is applied when
the anchor is expanded with the EAW
H Plus setting tool offers control of
the anchoring and provides increased
safety.

Pipelines and ventilation systems


Sprinkler systems
Cable conduits and wires
Gratings
Steel constructions
Machines
Consoles
Shuttering props

The EA II is suitable for pre-positioned


installation.
Position the hammerset anchor in
the drill hole and drive in flush to the
surface of the anchor base using the
hammer.
The sleeve is then expanded by driving
in the internal bolt with the EAW H
Plus setting tool (alternative: EA II-SDS
machine setting tool), and expanded
against the drill hole wall.
The setting tools must sit on the rim of
the anchor to ensure correct expansion.

INSTALLATION

29

EA II Hammerset anchor

Hammerset anchorEA II. Not suitable for diamond


drilling appliances and diamond saws.

Items to order only

Item

EA II M 6
EA II M 8
EA II M 8 x 40
EA II M 10 x 30
EA II M 10
EA II M 12
EA II M 16
EA II M 20

zinc-plated
steel

stainless
steel

Art.-No.
gvz

Art.-No.
A4

ETA

048264
048284
048323
048332
048339
048406
048408
048409

048410
048411
048412

048414
048415
048416
048417

Approval

High performance steel anchors

TECHNICAL DATA

Drill hole
diameter

Anchor
length

Internal
thread

do

Min. Drill
hole depth for
pre-positioned
installation
h1

[mm]

[mm]

[mm]

8
10
10
12
12
15
20
25

32
33
43
33
43
54
70
85

30
30
40
30
40
50
65
80

M6
M8
M8
M 10
M 10
M 12
M 16
M 20

Min. bolt
penetration

Max. bolt
penetration

Sales
unit

lE,min

lE,max

[mm]

[mm]

[pcs]

6
8
8
10
10
12
16
20

13
13
13
13
17
22
28
34

100
100
50
50
50
25
20
10

Associated setting tool for manual installation (EAW H plus), for installation with hammer drill (EA II-S-SDS)

ACCESSORIES
Setting tool EAW H Plus with
hand impact protection for your
safety and embossing tool.

Items to order only


Item

EAW H 6 Plus
EAW H 8 Plus
EAW H 8 x 40 Plus
EAW H 10 Plus
EAW H 10 x 30 plus
EAW H 12 Plus
EAW H 16 Plus
EAW H 20 Plus
EA-ST 12

Setting tool EA-ST

Fits

Sales unit
[pcs]

Art.-No.

044630
044631
044632
044633
048487
044634
044635
044636
504585

EA II M6
EA II M 8
EA II M 8 x 40
EA II M 10
EA II M 10 x 30
EA II M 12, EA II M 12 D
EA II M 16
EA II M 20
EA II M6

1
1
1
1
1
1
1
1
1

ACCESSORIES
Machine setting tool EA II S-SDS
Items to order only
Item

EA II S-SDS 6
EA II S-SDS 8
EA II S-SDS 8 x 40
EA II S-SDS 10 x 30
EA II S-SDS 10
EA II S-SDS 12
EA II S-SDS-M 16
EA II S-SDS-M 20
1) Delivery time on request.

30

Tool holder

Fits

SDS plus
SDS plus
SDS plus
SDS plus
SDS plus
SDS plus
SDS max
SDS max

EA II M6
EA II M 8
EA II M 8 x 40
EA II M 10 x 30
EA II M 10
EA II M 12 D / EA II M 12 / EA M 12 N D
EA II M 16
EA II M 20

Art.-No.

048065
048066
048067
048068 1)
048070
048071
048072 1)
048073 1)

Sales unit
[pcs]

1
1
1
1
1
1
1
1

EA II Hammerset anchor
LOADS - MULTIPLE USE , CRACKED CONCRETE

Type

EA II M6 / A4
EA II M8 / A4
EA II M8 x 40 / A4
EA II M10 x 30 / A4
EA II M10 / A4
EA II M12 / A4

Effective
anchorage depth
hef

Min.
member thickness
hmin

Maximum
torque moment
Tinst,max

[mm]

[mm]

30
30
40
30
40
50

100
100
100
120
120
120

The partial safety factors for material resistance as regulated in the approval as well as a partial
safety factor for load actions of L = 1,4 are considered.
2)
Minimum possible axial spacings resp. edge distance while reducing the permissible load.

1)

3)

Cracked or Non-cracked concrete


Permissible load
Min. spacing
Min. edge distance
Fperm3)

smin2)

cmin2)

[Nm]

[kN]

[mm]

[mm]

4,0
8,0
8,0
15,0
15,0
35,0

1,0
1,7
1,7
1,7
2,5
3,6

65
95
95
85
95
145

115
140
140
140
160
200

Valid for tensile load, shear load and oblique load under any angle. For combinations of tensile
loads, shear loads, bending moments as well as reduced edge distances or spacings (anchor
groups) see approval.

LOADS - SINGLE ANCHOR, NON-CRACKED CONCRETE


Hammerset anchor EA II (screw quality 8.8) / EA II A4 (screw quality A4 -70)
Highest permissible loads for a single anchor1) in concrete C20/254)
For the design the complete approval ETA - 07/0135 has to be considered.
Type

EA II M65) / / A45)
EA II M85) / A45)
EA II M8 x 40
EA II M10 x 305) / A45)
EA II M10 / A4
EA II M12 / A4
EA II M12D / A4
EA II M16 / A4
EA II M20 / D A4

Min.
member thickness
hmin

Maximum
torque moment
Tinst,max

Permissible
tensile load
Nperm3)

[mm]

[mm]

[Nm]

[kN]

[kN]

[mm]

[mm]

30
30
40
30
40
50
50
65
80

100
100
100
120
120
120
120
160
200

4,0
8,0
8,0
15,0
15,0
35,0
35,0
60,0
120,0

4,0
4,0
6,1
4,0
6,1
8,5
8,5
12,6
17,2

3,9
4,0
4,9
4,0
6,1
8,5
8,5
18,3
29,1

65
95
95
85
95
145
145
180
190

115
140
140
140
160
200
200
240
280

The partial safety factors for material resistance as regulated in the approval as well as a partial
safety factor for load actions of L = 1,4 are considered. As an single anchor counts e.g. an anchor with a spacing s 3 x hef and an edge distance c 1,5 x hef. Accurate data see approval.
2)
Minimum possible axial spacings resp. edge distance while reducing the permissible load.
1)

Non-cracked concrete
Permissible
Min.
shear load
spacing
Vperm3)
smin2)

Effective
anchorage depth
hef

Min.
edge distance
cmin2)

High performance steel anchors

Hammerset anchor EA II (screw quality 5.8) / EA II A4 (screw quality A4 -70)


Highest permissible loads1) for a single anchor for multiple use for non-structural applications in concrete C20/25 up to C50/60.
For the design the complete approval ETA - 07/0142 has to be considered.

For combinations of tensile loads, shear loads, bending moments as well as reduced edge
distances or spacings (anchor groups) see approval.
4)
For higher concrete strength classes up to C50/60 higher permissible loads may be possible.
5)
Only for multiple use for non-structural applications.
3)

31

FNA II Nail anchor


High performance steel anchors

The hammerset nail anchor for multiple fixings

Fire protection boards

VERSIONS

APPROVALS

zinc-plated steel
stainless steel
highly corrosion-resistant steel

BUILDING MATERIALS
Approved for:
Concrete C12/15 to C50/60,
cracked, for multiple fixings of nonstructural applications
Also suitable for:
Solid sand-lime brick
Natural stone with dense structure
Prestressed hollow-core concrete slabs

2
ADVANTAGES

APPLICATIONS

FUNCTIONING

The special design principle allows for


a simple hammerset installation and a
short processing time.
The extremely short anchor depth
prevents reinforcement hits, and
creates conditions for a trouble-free
installation.
The expansion clip ensures a firm
hold when placed in the drill hole, and
prevents it falling out during overhead
installations.
A range of different head shapes
allows for the fixing of wide-ranging
fixtures and for the ideal adaptation to
suit the intended use.

Fire protection plates


Fire protection boards
Ventilation systems
Wire and nonious hangers
Mounting rails
Metal clamps
Sub-structures made of wood or metal

The FNA II with nail head is suitable


for push-through installation. The
FNAIIM6 is suitable for pre-positioned
and push-through installation. The
FNA II OE and H are suitable for prepositioned installation.
The installed FNA II nail anchor
expands automatically under load. The
cone is pulled into the expansion clip
and expands it against the drill hole
wall.
Available setting tools:
FNAS-SBO to slip onto the drill.
FNAS-SDS for series installation with
a drilling hammer.
FNAS-H for the manual installation of
mounting rails.

INSTALLATION

32

Suspended ceilings

FNA II Nail anchor


TECHNICAL DATA

Item

FNA II 6 x 25/5
FNA II 6 x 30/5
FNA II 6 x 30/5
FNA II 6 x 30/20
FNA II 6 x 30/30
FNA II 6 x 30/30
FNA II 6 x 30/50
FNA II 6 x 30/75
FNA II 6 x 30/100
FNA II 6 x 30/120

zinc-plated
steel

stainless
steel

Art.-No.
gvz

Art.-No.
A4

044121 1)

044115 1) 044122

044116 044123

044117 046024

044118

044119

044120

highly
corrosion
resistant
steel
Art.-No.
C

044124
506147

044125
500569
500573 2)
500574 2)
500575 2)

do

Min. drill
hole depth for
through fixings
h2

t fix

ETA

[mm]

[mm]

[mm]

[mm]

[mm]

[pcs]

6
6
6
6
6
6
6
6
6
6

40
45
45
60
70
70
90
115
140
160

35
40
40
55
65
65
85
110
135
155

5
5
5
20
30
30
50
75
100
120

13
13
13
13
13
13
13
13
13
13

100
100
25
50
50
25
50
50
50
50

Approval

Items to order only

Drill hole
diameter

Anchor
length

Max. fixture
thickness

KD
head-

Sales
unit

1) with hexagon below the nail head for anti-rotation lock of hole and wire hangers (for example) and centring for optional setting tool FNA-S
2) On request.

High performance steel anchors

Nail anchor FNA II with nail head

TECHNICAL DATA

Nail anchor FNA II M6 with thread and


flange nut

Item

zinc-plated
steel

stainless
steel

highly
corrosion
resistant
steel

Art.-No.
gvz

Art.-No.
A4

Art.-No.
C

FNA II 6 x 25 M6/5 044111

FNA II 6 x 30 M6/5 044109


044112 2)

FNA II 6 x 30 M6/5

044113 2)
FNA II 6 x 30 M6/5

FNA II 6 x 30 M6 x 41 044110 1)

FNA II 6 x 30 M6/10 046022

FNA II 6 x 30 M8/5 044114


1) without nut; e.g. for fixing ofpipe clamps
2) with nut and washer (no flange nut)

do

Min. drill
hole depth
for through
fixings
h2

t fix

ETA

[mm]

[mm]

[mm]

[mm]

6
6
6
6
6
6
6

40
45
45
45
40
45
45

45
50
50
50
41
55
51

5
5
5
5

10
5

Approval

Items to order only

Drill hole
diameter

Anchor
length

Max. fixture
thickness

Thread

M6
M6
M6
M6
M6
M6
M8

Width
across nut

Sales
unit

SW
[mm]

[pcs]

10
10
10
10
10
10
13

100
100
50
25
100
100
50

33

FNA II Nail anchor

Nail anchorFNA II-H with hook


zinc-plated
steel

Items to order only

Art.-No.
gvz

Item

FNA II 6 x 25 H
FNA II 6 x 25 OE

044126
044127

Nail anchor FNA II-OE with eye


Drill hole
diameter

Approval

High performance steel anchors

TECHNICAL DATA

Anchor l
ength

Min. drill
hole depth

Inner diameter of the


hook/eye

Sales unit

do

h1

ETA

[mm]

[mm]

[mm]

[ mm]

[pcs]

6
6

54
54

35
35

10
10

50
50

TECHNICAL DATA
Machine setting tool FNA S-SDS
Machine setting tool FNA S-SBO for mounting on the drill bit (drill- 6mm)
Hand tool FNA S-H
Use

Items to order only


Item

Description

Sales unit

Art.-No.

[pcs]

FNA S-SDS

061547

for all FNA II with nail head

FNA S-SBO

061548

for all FNA II with nail head

FNA S-H

095990

for FNA II with metric thread M6

The ideal setting tool for the serial installation with SDS-plus adapter for
driving in FNA II with nail head using a hammer drill.
For a power saving and fast installation to be placed on the drill.
E.g. for the fixing of installation of mounting rails. Chuck with outer
diameter of 15mm for the installation of FNA II M6 by hand.

1
1
1

LOADS
Nail anchor FNA II
Highest permissible loads1) for a single anchor for multiple use for non-structural applications in concrete C20/25 up to C50/604).
For the design the complete approval ETA - 06/0175 has to be considered.
Type

FNA II 6 x 25
FNA II 6 x 30
FNA II 6 x 25 M6
FNA II 6 x 30 M6
FNA II 6 x 30 M8
FNA II 6 x 25 OE

Cracked or Non-cracked concrete


Permissible load
Min.
Min.
spacing
edge distance
Fperm3)
smin2)
cmin2)

Effective
anchorage depth
hef

Min.
member thickness
hmin

Maximum
torque moment
Tinst,max

[mm]

[mm]

[Nm]

[kN]

[mm]

[mm]

25
30
25
30
30
25

80
80
80
80
80
80

4,0
4,0
4,0
-

1,4
2,4
1,4
2,4
2,4
0,7

100
100
100
100
100
100

50
50
50
50
50
50

LOADS
Nail anchor FNA II A4 / FNA II C
Highest permissible loads1) for a single anchor for multiple use for non-structural applications in concrete C20/25 up to C50/604).
For the design the complete approval ETA - 06/0175 has to be considered.
Type

FNA II 6 x 30 A4 / C
FNA II 6 x 30 M6 A4 / C

Min.
member thickness
hmin

Maximum
torque moment
Tinst,max

[mm]

[mm]

[Nm]

[kN]

[mm]

[mm]

30
30

80
80

4,0

2,4
2,4

100
100

50
50

The partial safety factors for material resistance as regulated in the approval as well as a partial
safety factor for load actions of L = 1,4 are considered.
2)
Minimum possible axial spacings resp. edge distance while reducing the permissible load. The
combination of the given min. spacing and min. edge distance is not possible. One of them has
to be increased according approval.
1)

34

Cracked or Non-cracked concrete


Permissible load
Min.
Min.
spacing
edge distance
Fperm3)
smin2)
cmin2)

Effective
anchorage depth
hef

Valid for tensile load, shear load and oblique load under any angle. For combinations of tensile
loads, shear loads, bending moments as well as reduced edge distances or spacings (anchor
groups) see approval.
4)
Loads for concrete strength class C12/15 see approval.
3)

TA M BP Heavy-duty security anchor

BUILDING MATERIALS
Approved for:
Concrete C20/25 to C50/60, noncracked
Also suitable for:
Concrete C12/15
Natural stone with dense structure

APPLICATIONS

Collision protection

FUNCTIONING
The TA M is suitable for push-through
installation.
When applying the torque, the cone is
pulled into the expansion sleeve and
expands it against the drill hole wall.
The hexagonal head of the TA M BP is
tightened until it breaks off.

Steel constructions
Hand-rails
Consoles
Ladders
Cable conduits
Machines
Staircases
Gates
Faades

ADVANTAGES

VERSIONS

The optimised geometry minimises setting energy and enables the anchor to be
used in extremely narrow spaces. The TA M BP version of the TA M anchor has a
twist-off head which prevents the dismantling of the fixture. Ideal for use as an
anti-theft deterrent and break-in protection.

zinc-plated steel

High performance steel anchors

The installation-friendly push-through anchor for fixings in


non-cracked concrete

INSTALLATION

TECHNICAL DATA

Item

TA M8 BP

Heavy-duty anchor TA M BP
with twist-off head
zinc-plated
steel

Drill hole
diameter
do

Min. drill-hole depth for


through fixings
h2

Anchor
length
l

Max. fixture
thickness
t fix

Art.-No.
gvz

[mm]

[mm]

[mm]

[mm]

12

95

84

25

090265

Thread
M

Width
across nut
SW

Sales
unit

[mm]

[pcs]

13

50

M8

LOADS
Heavy-duty anchor TA M BP
Highest permissible loads for a single anchor1) in concrete C20/254) For the design the complete approval ETA - 04/0003 has to be considered.
Type

TA M6 BP

1)

Effective
Min.
anchorage depth substrate thickness

Installation
torque

Permissible
tensile load

Non-cracked concrete
Permissible
Min.
shear load
spacing

Min.
edge distance

hef
[mm]

hmin
[mm]

Tinst
[Nm]

Nperm3)
[kN]

Vperm3)
[kN]

smin2)
[mm]

cmin2)
[mm]

40

100

10,0

3,6

3,3

80

50

The partial safety factors for material resistance as regulated in the approval as well as a partial
safety factor for load actions of L = 1,4 are considered. As an single anchor counts e.g. an anchor with a spacing s 3 x hef and an edge distance c 1,5 x hef. Accurate data see approval.

Minimum possible axial spacings resp. edge distance while reducing the permissible load.
For combinations of tensile loads, shear loads, bending moments as well as reduced edge
distances or spacings (anchor groups) see approval.
4)
For higher concrete strength classes up to C50/60 higher permissible loads may be possible.
2)
3)

35

FA Through bolt
High performance steel anchors

The cost-effective demountable through bolt.

Guard rail

Stadium seating

VERSIONS
zinc-plated steel

ADVANTAGES

BUILDING MATERIALS

FUNCTIONING

The FA bolt can be demounted after


installation, leaving a flush surface.
The red collar prevents the anchor
rotating in the hole during installation.

Also suitable for:


Concrete B15
Natural stone with dense structure

The FA is for push-through installation.


When the hexagonal bolt is tightened,
the tapered cone is pulled into the
expansion sleeve and expands it
against the hole wall.

INSTALLATION

TECHNICAL DATA

drill

Art.-No.

do
[mm]

min. drill-hole
depth for
through fixings
td
[mm]

FA 8/15 (8x70)
FA 8/25 (8 x 85)
FA 10/15 (10 x 85)

500511
500512
500515

8
8
10

75
90
90

50
50
60

65
80
75

FA 10/50 (10 x 120)

500516

10

120

60

110

50

20

17

25

FA 12/15 (12 x 100)

500522

12

100

70

85

15

35

19

20

FA 12/50 (12 x 135)


FA 14/20 (14 x 115)
FA 14/50 (14 x 145)

500523
500526
500527

12
14
14

135
115
145

70
80
80

120
100
130

50
20
50

35
50
50

19
22
22

20
10
20

Type

min.
anchorage
depth
hv
[mm]

anchor
length

torque

width
across nut

l
[mm]

max.
fxing
thickness
da
[mm]

Scale units

Md

SW
[mm]

[pcs]

15
25
15

10
10
20

13
13
17

25
25
25

LOADS
Ultimate loads Fu, m [kN] (mean values) and recommended loads Frec [kN] for single anchors of through bolt FA in non-cracked concrete.
Anchor type/thread
Fu, m C20/25
Frec C20/25
Axial spacing
Edgae distance
Min. component thickness

36

C20/25
C20/25
[mm]
[mm]
[mm]

FA8
12.8
2.5
160
80
150

FA10
15.4
3.5
240
100
150

FA12
20.3
4.5
260
130
200

FA14
25.4
6.0
400
150
200

FSA Sleeve anchor


The push-through anchor for fixings in non-cracked concrete

Waste bins

VERSIONS

FUNCTIONING

zinc-plated steel

The FSA is suitable for push-through


installation.
When applying the torque, the cone is
pulled into the expansion sleeve and
expands it against the drill hole wall.
The half-moon shaped recesses act
as a crumple zone to take the torque
slippage, so that the attachment is
pulled onto the anchor base.

BUILDING MATERIALS
Suitable for:
Concrete C12/15 to C20/25
non-cracked
Natural stone with dense structure

ADVANTAGES

APPLICATIONS

The optimised geometry minimises


setting energy and enables the use in
extremely narrow spaces. This allows
for user-friendly installation.
The anchor design makes it possible to
use different head shapes for flexible
anchor solutions: Hexagon head (type
S), bolt version with nut and washer
(type B).
The detachable screw allows for
surface flush removal.

Hand-rails
Consoles
Ladders
Cable conduits
Gates
Faades

High performance steel anchors

Bicycle racks

Temporary
or structural
fixings

INSTALLATION

TECHNICAL DATA

Sleeve anchor FSA-S


zinc-plated
steel

Item

FSA 8/15 S (8x65)


FSA 8/40 S (8x70)
FSA 8/65 S (8x115)
FSA 10/10 S (10x65)
FSA 10/35 S (10x90)
FSA 10/60 S (10x115)
FSA 12/10 S (12x75)
FSA 12/25 S (12x90)
FSA 12/50 S (12x115)

Art.-No.
gvz

068520
068521
068522
068523
068524
068525
068526
068527
068528

Drill hole
diameter

Max. fixture
thickness

Anchor length

Thread

Width across nut

Sales unit

do
[mm]

Min. drill-hole
depth for through
fixings
h2
[mm]

t fix
[mm]

l
[mm]

SW
[mm]

[pcs]

8
8
8
10
10
10
12
12
12

65
90
115
65
90
115
75
90
115

15
40
65
10
35
60
10
25
50

64
89
114
65
90
115
76
91
116

M6
M6
M6
M8
M8
M8
M 10
M 10
M 10

10
10
10
13
13
13
17
17
17

50
50
50
20
20
20
20
20
20

37

FSA Sleeve anchor


High performance steel anchors

TECHNICAL DATA
Sleeve anchor FSA-B

Item

zinc-plated Drill hole diameter Min. drill-hole


steel
depth for through
fixings
h2
do
Art.-No.
[mm]
[mm]
gvz

FSA 8/15 B
FSA 8/40 B
FSA 8/65 B
FSA 10/10 B
FSA 10/35 B
FSA 10/60 B
FSA 12/10 B
FSA 12/25 B
FSA 12/50 B
FSA 12/75 B

068500
068501
068502
068503
068504
068505
068506
068507
068508
068509

8
8
8
10
10
10
12
12
12
12

Max. fixture
thickness

Anchor length

Thread

Width across nut

Sales unit

t fix
[mm]

l
[mm]

SW
[mm]

[pcs]

15
40
65
10
35
60
10
25
50
75

65
90
115
69
94
119
81
96
121
146

M6
M6
M6
M8
M8
M8
M 10
M 10
M 10
M 10

10
10
10
13
13
13
17
17
17
17

50
50
50
20
20
20
20
20
20
20

65
90
115
65
90
115
75
90
115
140

LOADS
Sleeve anchor FSA-B
Highest recommended loads2) for a single anchor in concrete C20/25.

Type

FSA 8
FSA 10
FSA 12
1)
2)

Effective
Min.
anchorage depth member thickness
hef
hmin

Installation
torque
Tinst

Recommended
tensile load
Nrec3)

Non-cracked concrete
Recommended
Min.
shear load
spacing
Vrec3)
smin 2)

Min.
edge distance
cmin 2)

[mm]

[mm]

[Nm]

[kN]

[kN]

[mm]

[mm]

35
40
50

70
80
100

8,0
25,0
40,0

2,0
3,5
5,0

3,4
6,3
9,9

70
80
100

50
60
75

Required safety factors are considered.


Minimum possible axial spacings resp. edge distance while reducing the recommended load.

3)

For combinations of tensile loads and shear loads the given loads have to be reduced.

TECHNICAL DATA
Sleeve anchor FSA-GB

Items to order only

FSA GB 6/5 (6x25)


FSA GB 6/8 (6x35)
FSA GB 6/25 (6x56)
FSA GB 8/8 (8x40)
FSA GB 8/30 (8x65)
FSA GB 8/55 (8x85)
FSA GB 10/10 (10x50)
FSA GB 10/35 (10x70)
FSA GB 10/60 (10x97)
FSA GB 12/12 (12x60)
FSA GB 12/20 (12x75)
FSA GB 12/50 (12x99)
FSA GB 12/75 (12x129)
FSA GB 16/12 (16x65)
FSA GB 16/50 (16x111)
FSA GB 16/80 (16x147)
FSA GB 20/20 (20x82)
FSA GB 20/95 (20x151)
38

zinc-plated
steel

Drill hole
diameter

Min. drill-hole depth for


through fixings

Max. fixture
thickness

Anchor
length

Thread

do

h2

Art.-No
gvz

[mm]

[mm]

t fix

[mm]

[mm]

42672
42661
42662
42663
42655
42664
42665
42656
42657
42666
42658
42659
42667
42668
42660
42669
42670
42671

6
6
6
8
8
8
10
10
10
12
12
12
12
16
16
16
20
20

20
20
20
25
25
25
30
30
30
40
40
40
40
40
40
40
50
50

5
8
25
8
30
55
10
35
60
12
20
50
75
12
50
80
20
95

25
35
56
40
65
85
50
70
100
60
75
100
130
65
110
150
80
150

Width across
nut
SW
[mm]

M 4.5
M 4.5
M 4.5
M6
M6
M6
M8
M8
M8
M 10
M 10
M 10
M 10
M 12
M 12
M 12
M 16
M 16

Sales unit

[pcs]

100
100
100
100
100
25
25
25
25
25
25
20
20
20
10
10
10
5

FSA Sleeve anchor


TECHNICAL DATA

zinc-plated
steel
Art.-No
gvz

FSA GB 8/10 A2 (8x45)


FSA GB 8/25 A2 (8x65)
FSA GB 10/5 A2 (10x50)
FSA GB 10/25 A2 (10x70)
FSA GB 10/55 A2 (10x100)
FSA GB 10/75 A2 (10x120)
FSA GB 12/10 A2 (12x60)
FSA GB 12/25 A2 (12/80)
FSA GB 12/45 A2 (12x100)
FSA GB 12/65 A2 (12x120)

42574
42575
42576
42577
42578
42579
42580
42581
42582
42583

Drill hole Min. drill-hole depth for Max. fixture


diameter
through fixings
thickness
do
h2
t fix
[mm]
[mm]
[mm]

8
8
10
10
10
10
12
12
12
12

25
30
30
35
35
35
35
40
40
40

10
25
5
25
55
75
10
25
45
65

Anchor
length
l
[mm]

Thread

45
65
50
70
100
120
60
80
100
120

M6
M6
M8
M8
M8
M8
M 12
M 12
M 12
M 12

Width across
nut
SW
[mm]

Sales unit

[pcs]

100
50
50
50
25
25
25
25
20
20

High performance steel anchors

Sleeve anchor FSA-GB A2

39

High performance steel anchors

FWB Wallbolt
The traditional shield anchor widely used in non-cracked
concrete

Metal construction

VERSIONS

FUNCTIONING

zinc-plated steel for indoor use

The FSA is for pre-positioned, flush


fixing.
For push-through installation.
When applying the torque, the cone is
pulled into the expansion sleeve and
expands it against the drill hole wall.
The half-moon shaped recesses act
as a crumple zone to take the torque
slippage, so that the attachment is
pulled onto the anchor base.

BUILDING MATERIALS
Suitable for:
Non-cracked Concrete > C12/15
Dense natural stone
Dense solid stone
Good quality masonry

2
ADVANTAGES

APPLICATIONS

FUNCTIONING

The segmented steel expansion shield


is pre-assembled ready for use.
Versatile: The internal metric thread
makes this wallbolt suitable for a
number of different head types.
The three piece shield distributes and
even load when installed.
Surface flush which allows the fixture
to be removed.
Traditional design widely accepted by
end users.

Hand-rails
Ventilation ducts
Pipework
Suspended ceilings
Metal construction
Metal profiles
Also suitable for temporary fixings
such as wall shuttering

For pre-positioned and flush fixings.


The wallbolt works by torque controlled,
friction locking expansion.
When the screw or hex. nut is
tightened the cone is pulled up into
the expansion shield and pushes the
segments against the drill hole wall.
For best results ensure the drill hole is
dust free.

INSTALLATION

40

Ventilation ducts

FWB Wallbolt
TECHNICAL DATA

zinc-plated
steel

Item

Art.-No.
Shield only

FWB M6 S
FWB M8 S
FWB M10 S
FWB M12 S
FWB M16 S
FWB M20 S

044963
044964
044965
044966
044967
044970

Drill hole
dia.

Thread

Total
length

Min.
anchorage
depth
hef
> [mm]

Min. bolt
penetration

Installation
torque

Sales
unit

h2
[mm]

Min.
drill-hole
depth
h1
> [mm]

do
[mm]

d1M
[mm]

> [mm]

e2

Tinst
[Nm]

[pcs]

12
14
16
20
25
32

6
8
10
12
16
20

45
50
60
75
115
130

50
60
70
85
130
150

35
40
50
60
95
110

40
45
55
70
105
120

10
25
40
75
180
220

25
25
25
25
10
10

screw dia.
X
length

Installation
torque

Sales
unit

[pcs]

TECHNICAL DATA
FWB L Loosebolt with
hex head screw
zinc-plated
steel

Item

Art.-No.
Shield only

FWB M6 x 55L
FWB M6 x 70L
FWB M6 x 85L
FWB M8 x 65L
FWB M8 x 80L
FWB M8 x 95L
FWB M10 x 75L
FWB M10 x 90L
FWB M10 x 115L
FWB M10 x 140L
FWB M12 x 90L
FWB M12 x 105L
FWB M12 x 120L
FWB M12 x 140L
FWB M16 x 135L
FWB M16 x 150L
FWB M16 x 180L
FWB M20 x 195L

044976
044977
044978
044979
044990
044991
044992
044993
044994
044995
044996
044997
044998
044999
045079
045099
045108
045109

Drill hole
dia.

Thread

Total
length

do
[mm]

d1M
[mm]

12
12
12
14
14
14
16
16
16
16
20
20
20
20
25
25
25
32

6
6
6
8
8
8
10
10
10
10
12
12
12
12
16
16
16
20

High performance steel anchors

FWB shield

2
Min.
anchorage
depth
hef
> [mm]

Max.
fixing
thickness
tfix
> [mm]

Min. bolt
penetration

h2
[mm]

Min.
drill-hole
depth
h1
> [mm]

> [mm]

[mm]

Tinst
[Nm]

45
45
45
50
50
50
60
60
60
60
75
75
75
75
115
115
115
130

50
50
50
60
60
60
70
70
70
70
85
85
85
85
125
125
125
130

35
35
35
40
40
40
50
50
50
50
60
60
60
60
95
95
95
110

10
25
40
10
25
40
10
25
50
75
10
25
40
60
15
30
60
60

40
40
40
45
45
45
55
55
55
55
70
70
70
70
95
95
95
110

M6 x 55
M6 x 70
M6 x 85
M8 x 65
M8 x 80
M8 x 95
M10 x 75
M10 x 90
M10 x 115
M10 x 140
M12 x 90
M12 x 105
M12 x 120
M12 x 140
M16 x 135
M16 x 150
M16 x 180
M20 x 195

10
10
10
25
25
25
40
40
40
40
75
75
75
75
180
180
180
220

e2

25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25

41

FWB Wallbolt
High performance steel anchors

TECHNICAL DATA

FWB P Projecting bolt


(threaded rod, washer & nut)
zinc-plated
steel

Item

Art.-No.
Shield only

FWB M6 x 65P
FWB M6 x 80P
FWB M6 x 115P
FWB M8 x 75P
FWB M8 x 90P
FWB M8 x 125P
FWB M10 x 90P
FWB M10 x 105P
FWB M10 x 135P
FWB M10 x 110P
FWB M12 x 125P
FWB M12 x 170P
FWB M20 x 185P

044976
044977
044978
044979
044990
044991
044992
044993
044994
044995
044996
044997
044998

Drill hole
dia.

Thread

Total
length

Min.
anchorage
depth
hef
> [mm]

Max.
fixing
thickness
tfix
> [mm]

Min. bolt
penetration

h2
[mm]

Min.
drill-hole
depth
h1
> [mm]

do
[mm]

d1M
[mm]

> [mm]

12
12
12
14
14
14
16
16
16
16
20
20
20

6
6
6
8
8
8
10
10
10
10
12
12
12

Installation
torque

Sales
unit

[mm]

Tinst
[Nm]

[pcs]

45
45
45
50
50
50
60
60
60
60
75
75
75

50
50
50
60
60
60
70
70
70
70
85
85
85

35
35
35
40
40
40
50
50
50
50
60
60
60

10
25
40
10
25
40
10
25
50
75
10
25
40

40
40
40
45
45
45
55
55
55
55
70
70
70

M6 x 55
M6 x 70
M6 x 85
M8 x 65
M8 x 80
M8 x 95
M10 x 75
M10 x 90
M10 x 115
M10 x 140
M12 x 90
M12 x 105
M12 x 120

10
10
10
25
25
25
40
40
40
40
75
75
75

25
25
25
25
25
25
25
25
25
25
25
25
25

Min.
anchorage
depth
hef
> [mm]

Max.
fixing
thickness
tfix
> [mm]

Min. bolt
penetration

screw dia.
X
length

Installation
torque

Sales
unit

> [mm]

[mm]

Tinst
[Nm]

[pcs]

e2

screw dia.
X
length

TECHNICAL DATA
FWB E Eye bolt

zinc-plated
steel

Item

Art.-No.
Shield only

FWB M6 x 73E
FWB M8 x 87E
FWB M10 x 108E
FWB M12 x 130E

045270
045290
045402
045419

Drill hole
dia.

Thread

Total
length

do
[mm]

d1M
[mm]

h2
[mm]

Min.
drill-hole
depth
h1
> [mm]

12
14
16
20

6
8
10
12

45
50
50
75

50
60
70
85

35
40
50
60

40
45
55
70

M6 x 73
M8 x 87
M10 x 108
M12 x 130

10
25
40
75

25
25
25
25

Min.
anchorage
depth
hef
> [mm]

Max.
fixing
thickness
tfix
> [mm]

Min. bolt
penetration

screw dia.
X
length

Installation
torque

Sales
unit

> [mm]

[mm]

Tinst
[Nm]

[pcs]

35
40
50

40
45
55

M6 x 83
M8 x 98
M10 x 120

10
25
40

25
25
25

e2

TECHNICAL DATA
FWB H Hook bolt

zinc-plated
steel

Item

Art.-No.
Shield only

FWB M6 x 73H
045533
FWB M8 x 87H
045534
FWB M10 x 108H 045535

42

Drill hole
dia.

Thread

Total
length

do
[mm]

d1M
[mm]

h2
[mm]

Min.
drill-hole
depth
h1
> [mm]

12
14
16

6
8
10

45
50
50

50
60
70

e2

FWB Wallbolt
LOADS
FWB 6S
gvz

FWB 8S
gvz

FWB 10S
gvz

FWB 12S
gvz

Effective anchorage depth


hef
[mm]
35
40
50
60
Recommeneded tension loads Nrec of single anchors without edge spacing influence
[mm]
1.5
2.0
4.0
6.0
In non-cracked concrete C20/25
Nrec
Recommeneded Shear loads Vrec of single anchors without edge spacing influence
[kN]
1.5
2.0
4.0
6.0
In non-cracked concrete C20/25
Vrec
Components dimensions and insulation parameters
[kN]
55
60
75
90
Minimum edge distance
cmin
[mm]
110
120
150
180
Minimum spacing
smin
[mm]
100
100
100
120
Minimum structural component thickness
hmin
[mm]
12
14
16
20
Nominal drill hole diameter
de
[mm]
50
60
70
85
Drill hole depth
h1 $
[mm]
7
9
12
14
Clearance-hole in the fixture to be attached
d1 $
[Nm]
10
25
40
75
Installation torque
T1 $
All values apply for non-cracked concrete C20/25 with normal reinforcement or not reinforced without edge or spacing influences.
Recommended loads: material safety factor M and safety factor for load L =1.4 are included.

FWB 16S
gvz

FWB 20S
gvz

95

110

8.0

8.0

8.0

8.0

145
290
190
25
130
18
180

165
330
220
32
150
22
220

High performance steel anchors

Anchor type
Steel

43

FDBB Fixing set for diamond drills


High performance steel anchors

The reusable fixing system for diamond drills and saws

Diamond drills

Detail: Diamond drills

APPLICATIONS

VERSIONS

FUNCTIONING

Diamond and core drilling devices


Diamond saws

zinc-plated steel

The FDBB is suitable for pre-positioned


and push-through installation.
An expansion element must be added
to the spindle bolt before installation.
Use a hammer to drive the FDBB
through the base plate of the drilling
device into the drill hole.
When the nut is tightened, the cone
bolt is pulled into the expansion clip
and expands it against the drill hole
wall.
The expansion element remains in the
drill hole when dismantling the spindle
bolt. The spindle bolt is once again
completed with an expansion element
and can be reused.

BUILDING MATERIALS
Suitable for:
Concrete C12/15 to C50/60, noncracked
Natural stone with dense structure

ADVANTAGES
The detachable screw connection between the expansion element and spindle
enables simple dismantling and ensures that the spindle bolt can be reused.
The robust, reusable spindle bolt guarantees a long life span.
The active principle of the anchor bolt enables an active controlled expansion, thus
offering a high level of safety.
The large steel cross-section provides high shear load-bearing capability and, as such,
high security for the jerky stoppage of the drill bit.

INSTALLATION

TECHNICAL DATA

Expansion element FDBB SE

Fixing set for diamond drills FDBB

Item

zinc-plated
steel

Drill hole
diameter

Usable
length

Min. drill-hole Width across nut


depth for through
fixings
h2
SW

Length

do

tfix

Art.-No.
gvz

[mm]

[mm]

[mm]

[mm]

[mm]

Contents

Sales unit

FDBB 16/50 Set

090680

16

50

135

27

200

FDBB 16 SE

090681

16

[pcs]
1 expansion element 16 SE,
1 spindle bolt 16/50/160,
1 washer, 1 nut
Expansion element

1
25

LOADS
Fixing set for diamond drills FDBB
Highest recommended loads1) for a single anchor in non-cracked concrete.
C20/25
Type

Recommended
tensile load
Nrec

Recommended
shear load
Vrec2)

Recommended
tensile load
Nrec

Recommended
shear load
Vrec2)

[Nm]
98,0

[kN]
12,0

[kN]
13,3

[kN]
9,0

[kN]
13,3

FDBB
1)

44

C12/15

Recommended
bending moment
Mrec

Required safety factors are considered.

2)

Steel failure value.

FHY Hollow ceiling anchor

Air conditioning units in pre-stressed hollowcore concrete slabs

Cable trays in pre-stressed hollow-core concrete


slabs

VERSIONS

APPROVALS

zinc-plated steel
stainless steel

BUILDING MATERIALS
Approved for:
Pre-stressed hollow-core concrete
slabs C45/55

ADVANTAGES

APPLICATIONS

FUNCTIONING

The active principle of the anchor


means that the FHY can be used in
cavities or in solid materials up to 5 cm
from the tensioning wire. This ensures
the highest flexibility and user-friendly
installation.
The embossed edge prevents the
anchor sleeve from slipping in the
cavity, thus allowing for trouble-free
installation.
The optimised geometry minimises
setting energy and allows for use in
extremely narrow spaces. This allows
for user-friendly installation.
The metric internal thread means that
it is possible to use standard screws or
threaded rods for the ideal adaptation
to suit the intended use.

Pipes
Cable conduits
Ventilation systems
Sprinkler systems
Suspended ceilings
Consoles
Steel constructions
Wood constructions

The FHY is suitable for pre-positioned


installation.
Put the FHY hollow-ceiling anchor in
the drill hole and drive in flush to the
surface of the anchor base using the
hammer.
The FHY pre-positioned anchor
must be able to be supported on the
attachment for expansion.
When applying the torque, the cone is
pulled into the expansion sleeve and
expands it into the cavity or expands
it in the solid material against the drill
hole wall.
Screw length ls =
Minimum screw-in depth e2
+ Thickness of fixture tfix
+ Thickness of washer
(with threaded rod: + height of nut)

High performance steel anchors

The installation-friendly internally threaded anchor for fixings


in pre-stressed hollow-core concrete slabs

INSTALLATION

45

FHY Hollow ceiling anchor

Hollow-ceiling anchor FHY, zinc-plated steel

Items to order only

Item

FHY M 6
FHY M 6
FHY M 8
FHY M 8
FHY M10
FHY M10

Drill hole
diameter

Anchor
length

Thread

do

[mm]

[mm]

zinc-plated
steel

stainless
steel

Art.-No.
gvz

Art.-No.
A4

DIBt

030138

030146

030148

030139

030147

030151

10
10
12
12
16
16

37
37
43
43
52
52

Approval

High performance steel anchors

TECHNICAL DATA

M6
M6
M8
M8
M 10
M 10

Min. drill
hole depth

Min. bolt
penetration

Sales
unit

h1

lE,min

[mm]

[mm]

[pcs]

50
50
60
60
65
65

37
37
43
43
52
52

50
50
25
25
20
20

LOADS
Hollow-ceiling anchor FHY (screw with grade 5.8)
Highest permissible loads1) for a single anchor in pre-stressed hollow-core concrete slabs of strength class B55 resp. C45/55.
For the design the complete approval Z-21.1-1711 has to be considered.
Type

FHY M6

FHY M8
FHY M10
1)
2)

Pre-stressed hollow-core concrete slabs


Permissible load
Min. spacing
Min. edge distance

Web thickness

Min. anchorage depth

Torque moment

du

hef

Tinst

Fperm3)

smin2)

cmin2)

[mm]

[mm]

[Nm]

[kN]

[mm]

[mm]

25 - 29
30 - 39
40
25 - 29
30 - 39
40
30 - 39
40

30
30
30
35
35
35
40
40

10,0
10,0
10,0
10,0
10,0
10,0
20,0
20,0

0,7
0,9
2,0
0,7
0,9
2,0
1,2
3,0

70
80
100
70
80
100
80
100

100
100
100
100
100
100
100
100

The required safety factors as regulated in the approval are considered.


Minimum possible axial spacings resp. edge distance while reducing the permissible load.

3)

Valid for tensile load, shear load and oblique load under any angle. For combinations of tensile
loads, shear loads, bending moments as well as reduced edge distances or spacings (anchor
groups) see approval.

LOADS
Hollow-ceiling anchor FHY A4 (screw with grade A4-70)
Highest recommended loads1) for a single anchor in pre-stressed hollow-core concrete slabs of strength class B55 resp. C45/55.
Type

FHY M6 A4

FHY M8 A4
FHY M10 A4
1)
2)

46

Pre-stressed hollow-core concrete slabs


Recommended load
Min. spacing
Min. edge distance

Web thickness

Min. anchorage depth

Torque moment

du

hef

Tinst

Frec3)

smin2)

cmin2)

[mm]

[mm]

[Nm]

[kN]

[mm]

[mm]

25 - 29
30 - 39
40
25 - 29
30 - 39
40
30 - 39
40

30
30
30
35
35
35
40
40

10,0
10,0
10,0
10,0
10,0
10,0
20,0
20,0

0,7
0,9
2,0
0,7
0,9
2,0
1,2
3,0

70
80
100
70
80
100
80
100

100
100
100
100
100
100
100
100

Required safety factors are considered.


Minimum possible axial spacings resp. edge distance while reducing the recommended load.

3)

Valid for tensile load, shear load and oblique load under any angle.

Decisive factors
Technical disclaimer / Decisive factors

This document is a factual record of anchor performance obtained under specific


conditions and does not constitute an endorsement of the suitability of the product for
any specific application. This responsibility remains with the customer.
The data given shall be used as a guide for assessment or anchor suitability. Even when
our advise is given in good faith it cannot be binding for this reason and we cannot accept
any liability for any anchor failure due to the wrong design, misuse or wrong installation.
For safety critical applications only anchors with an ETA or Zulassung German Approval
shall be used.
For further product information please contact the fischer Technical Department:
Phone: 01491 827 920
E-mail: technical@fischer.co.uk
fischer fixings (UK) Ltd.
Whitely Road, Wallingford, Oxon, OX10 9AT.
We cannot be responsible for any errors, and we reserve the right to make technical and
range modifications without notice.
No liability is accepted for printing errors and omissions.

High performance steel anchors

Due to the complexity of building materials, tools, fixing elements and installation
techniques a comprehensive recommendation depends on full and detailed
understanding of specific site conditions.

General Notice
The information in this brochure is intended for general guidance only and is given
without engagement. Additional information and advice on specific applications is
available from our Technical Support Team. For this however, we require a precise
description of your particular application.
All the data in this brochure concerning work with our fixings must be adapted to
suit local conditions and the type of materials in use.
If no detailed performance specifications are given for certain articles and types,
please contact our Technical Service Department for advice.
Phone: 01491 827 920
E-mail: technical@fischer.co.uk

47

Contacts
fischer fixings UK Ltd.
Whitely Road
Oxon OX10 9AT Wallingford
Great Britain
Phone (0044) 1491 827900
Fax (0044) 1491 827953
E-mail info@fischer.co.uk
www.fischer.co.uk
Technical Service
If you need any assistance, simply contact your local fischer
representative. For more specialised application problems
please contact our Technical Services Team.

Your dealer:

fischer fixings UK Ltd. Wallingford, Oxon, OX10 9AT.


Phone
e-mail:

01491 827 920


technical@fischer.co.uk

Technical Training
We also offer training seminars
suited to your individual needs and
requirements.
Please call the number above to find
out more

www.fischer.co.uk
48

High performance steel anchors / 2 of 12 product sections / 01/2013 (V1) Printed in the UK

01/2013