THINKING AHEAD

Addressable Intelligent
Fire Detection and Alarm System

In case of FIRE
lift the lid
press for alarm

FIRE

ISOLATOR

FIRE ALARM

31.10.2014 FRI

SYSTEM STATUS
HEALTHY

15 : 05: 35

DETECTOR

MENU

SILENCE

RESET

RESOUND
ALARM

SOUNDER BEACON

In case of FIRE
lift the lid
press for alarm

FIRE

CALL POINT
CONTROL PANEL

Addressable Intelligent Fire Detection and Alarm System is beneficial in many ways and
certainly adds more flexibility, intelligence, speed to identification process. For this reason,
Addressable intelligent Systems are most favored for large premises and more complex system
requirements. In addressable system detectors, call points, sounders are wired around the
building and connected to fire panel. Each device is assigned with a unique address' and
therefore the fire panel is able to display/indicate the precise location of the device in question
hence speeding up the location identification process saving time, life and property.
The Fire panel provides uninterrupted power to the detectors, sounders and all other devices
connected to the loop. It also continuously receives status reports from individual detector
comprising its health, live temperature, presence of smoke along with it's level etc. Based on
collected information, the system provides pre-alarm warnings when smoke/heat levels reach
a pre-set level enabling investigation of fire prior to a full evacuation alarm and fire brigade
signaling. Each alarm sounders have an individual 'address' with which they are triggered
automatically only at those zones where alarming is required leaving the other places
undisturbed. Addressable system is efficient in reporting far more than just fire or fault
conditions, for example panel can signal those smoke detectors that are contaminated with
dust etc. enabling maintenance necessities.

AASC - V.01 - 05.02.2015

www.airlight.in

THINKING AHEAD

System

FIRE
FIRE ALARM
17

SYSTEM ON

18

FIRE

19

GENERAL FAULT

20

SYSTEMF AULT

1
2

31.10.2014 FRI

POWER FAULT

21
22

SOUNDER DISABLED

23

SYSTEM DISABLED

24

TEST CONDITION

9
10
11

FIRE ALARM

26
27
28
29

14

30

15

31

16

32

10,Oct 2014
10:45
6

10

11

12

13

1
ABC
4
JKL

BATTERY LOW

SILENCE

RESET

14

2
DEF
5
M NO

15

16

3
GHI
6
PQR

7
STU

8
VWX

9
YZ

ESC

0
[ ]-

SHF

A A 1 0 3 F L P

15 : 05: 35

25

12
13

MAINS FAIL

15 : 05: 35

31.10.2014 FRI

SYSTEM STATUS
HEALTHY

Healthy
2

SYSTEM ON

SYSTEM STATUS
HEALTHY

LAMP TEST

MENU

SILENCE

RESOUND
ALARM

RESET

SILENCE
RESOUND ALARM

MENU

RESET

SILENCE

RESET

RESOUND
ALARM

AA103FLP

Intelligent Addressable
Fire Alarm Control Panel
AA103FP

Intelligent Addressable
Fire Alarm Control Panel - 1 Loop

AU101FACP
System

Intelligent Addressable
Fire Alarm Control Panel

FIRE

Healthy
3

10,Oct 2014
10:45
6

10

11

12

13

14

15

16

FIRE ALARM

SYSTEM ON

1
ABC

MAINS FAIL

4
JKL

BATTERY LOW

SILENCE

RESET

2
DEF
5
MNO

3
GHI

8
VWX

9
YZ

0
[ ]-

SHF

31.10.2014 FRI

SYSTEM STATUS
HEALTHY

6
PQR

7
STU

ESC

15 : 05: 35

A A 1 0 3 F L P

MENU

RESET

SILENCE

RESOUND
ALARM

AA103LPR

Intelligent Addressable Repeater Panel

AA103MRP

Intelligent Addressable Repeater Panel

UPS
ROOM

ELECTRICITY
ROOM

SERVER ROOM

SEC

HOD OF MM

TOILET

LIFT

LOBBY

D423

AA103SD
Optical Smoke Detector

AA103HD
Heat Detector

AU101MD
Multisensor

D482

D481

D414

WAITING

AA103LPG

D442
ANTI
ROOM

D421

LIFT

D420
D413

Gas Leak Detector

D422

MM DEPARTMENT

D412

D425

D419
D424

15th Floor

D426

WTC DEPARTMENT

D427

424 - WTC DEPARTMENT

AL103PGS

Panel Graphic Software

In case of FIRE
lift the lid
press for alarm

FIRE

AA103WCP
Weather Proof
Call Point

AA104CP
Manual Call Point

AA103SCI

Short Circuit Isolator

AA103RI

Response Indicator

AASC - V.01 - 05.02.2015

AA103FCP
Flame Proof
Call Point

AA104SB
Sounder Beacon

AU101SIM

AU101SOM

AL103GRS

Input Module

Output Module

PC Graphic Software

www.airlight.in