Description
ISSUE 1.0
1
Objectives
Internal Use 2
Chapter 1 Network Application and System structure
Chapter 2 Sub-rack
Internal Use 3
Network Application
OptiX OSN 9500
OptiX OSN 7500 OptiX OSN 7500
Core
Convergence
layer
Access layer
Switching /
Ethernet
Base Station
Internal Use 4
System Structure
E1 service
STM-1 optical VC-4 VC-4
and Ethernet
signal
service
Line 4x4
Tributary
unit VC-4 unit
Cross-
STM-1 optical connect
signal E1 service
unit and Ethernet
service
External
power Power Clock SCC
unit unit
supply unit
Internal Use 5
System Features
Internal Use 6
Chapter 1 Network Application and System Features
Chapter 2 Sub-rack
Internal Use 7
Sub-rack
200mm
42mm
436mm
Internal Use 8
Sub-rack
Indicators
NM-LAN
Power Supply
Optical interface
-48V/-60V/24V DC
110/220V AC Audible alarm Cut
RST 8×E1
Lamp Test
Power Switch Alarm input/output
10M/100M Ethernet interface
Internal Use 9
Sub-rack
Indicators
Indicator Status Description
E1 1–8 (multicolor indicator Flashing, red Major alarms (not E1-LOS) occur to E1 path.
alerting loss of E1 signal) Constantly on, orange Minor alarm occurs to E1 path.
Flashing, orange BIPEXC alarm occurs to E1 path.
Constantly on, green E1 path is in use and no alarm occurs.
On The link connection is normal.
LNK (green)
Indicator of Off The link is not connected or broken.
RJ-45 Flash or on Data are being transmitted.
ACT (yellow)
Off No data is being transmitted.
Internal Use 10
Chapter 1 Network Application and System Features
Chapter 2 Sub-rack
Internal Use 11
Equipment Cards
Ethernet Unit
SDH Unit
PDH Unit
Internal Use 12
PDH Unit
Send to SCC
Cautions
Internal Use 13
PDH Unit
Alarm List
Internal Use 14
Ethernet Unit
N×VC12
Ethernet
GFP
10M/100M
Unit 1×VC4 VC4
N×VC3
Internal Use 15
Ethernet Unit
Alarm List
Internal Use 16
SDH Unit
Internal Use 17
SDH Unit
Send to SCC
Interface Type:
Collect Alarm and
SC or LC
performance
SDH
STM-1 VC4
Unit
Provides inloop/outloop for
VC4,Electrical/optical interface
Internal Use 18
SDH Unit
Alarm List
Alarm name Alarm Description Level
R_LOF Receive loss of frame Critical
R_LOS Receive loss of signal Critical
HARD_BAD Hardware fails Critical
MS_AIS Multiplex section alarm indication Major
AU_AIS AU alarm indication signal Major
B2_EXC Multiplex section B2 excessive bit error indication Major
B3_EXC High order path B3 excessive bit error indication Major
BD_STATUS Board not in position alarm Major
B1_EXC Regenerator section B1 excessive bit error indication Minor
MS_RDI Multiplex section remote defect indication Minor
HP_RDI Higher order path remote defect indication Minor
HP_REI Higher order path remote error indication Minor
HP_TIM Higher order path tracking identifier mismatch Minor
LOOP_ALM Loop alarm Minor
Internal Use 19
Clock Unit
Clock
System
E1 Clock source ( 1 ) SDH Unit
Clock
Unit
Ethernet Unit
Internal source ( 1 )
Notes
When the OptiX Metro 100 is configured as a (TM), and clock unit is STGT, the clock
supports the locked mode and free-run mode.The others can supports locked mode,
holdover mode and free-run mode.
Internal Use 20
Clock Unit
Alarm List
Internal Use 21
Cross-Connect Unit
Functions
Provides the service grooming capability of the add/drop
multiplexer (ADM).
Alarm
BD_STATUS Major alarm
Internal Use 22
SCC Unit
SDH Unit
Alarm Alarm
PDH Unit SCC and
Ethernet Unit Performance
DCC
Metro 100
Internal Use 23
SCC Unit
Alarm List
Internal Use 24
Chapter 1 Network Application and System Features
Internal Use 25
Equipment Level Protection
Failed
Input PWR1 Input PWR2
Internal Use 26
Summary
Equipment Cards
Internal Use 27