External Pressure Calculations :
Step:

11:28pm

Page 1 of 3
Jun 27,2016

External Pressure Calculation Results :


ASME Code, Section VIII, Division 1, 2013
Elliptical Head From 10 to 20 Ext. Chart: CS-2 at 35 C

Elastic Modulus from Chart: CS-2 at 35 C

: 0.200E+09 KPa.

Results for Maximum Allowable External Pressure (MAEP):


Tca
OD
D/t
Factor A
B
8.000
1948.00
243.50
0.0005704
57.03
EMAP = B/(K0*D/t) = 57.0257/(0.9000 *243.5000 ) = 260.1981 KPa.
Results for Required Thickness (Tca):
Tca
OD
D/t
Factor A
B
4.992
1948.00
390.19
0.0003560
35.59
EMAP = B/(K0*D/t) = 35.5876/(0.9000 *390.1855 ) = 101.3351 KPa.
Check the requirements of UG-33(a)(1) using P = 1.67 * External Design
pressure for this head.
Material UNS Number:

K02700

Required Thickness due to Internal Pressure [tr]:

= (P*D*Kcor)/(2*S*E-0.2*P) Appendix 1-4(c)


= (169.213*1932.0001*0.999)/(2*137.90*1.00-0.2*169.213)
= 1.1839 + 1.0000 = 2.1839 mm.
Max. Allowable Working Pressure at given Thickness, corroded [MAWP]:

= ((2*S*E*t)/(Kcor*D+0.2*t))/1.67 per Appendix 1-4 (c)


= ((2*137.90*1.00*8.0000)/(0.999*1932.0001+0.2*8.0000))/1.67
= 684.186 KPa.

Maximum Allowable External Pressure [MAEP]:


= min( MAEP, MAWP )
= min( 260.20 , 684.1862 )
= 260.198 KPa.
Thickness requirements per UG-33(a)(1) do not govern the required
thickness of this head.
Cylindrical Shell From 20 to 30 Ext. Chart: CS-2 at 35 C

Elastic Modulus from Chart: CS-2 at 35 C

: 0.200E+09 KPa.

Results for Maximum Allowable External Pressure (MAEP):


Tca
OD
SLEN
D/t
L/D
Factor A
B
8.000
1948.00
3433.67
243.50
1.7627 0.0001943
19.43
EMAP = (4*B)/(3*(D/t)) = (4*19.4300 )/(3*243.5000 ) = 106.3870 KPa.
Results for Required Thickness (Tca):
Tca
OD
SLEN
D/t
L/D
Factor A
B
7.856
1948.00
3433.67
247.96
1.7627 0.0001885
18.85
EMAP = (4*B)/(3*(D/t)) = (4*18.8457 )/(3*247.9618 ) = 101.3308 KPa.
Results for Maximum Stiffened Length (Slen):
Tca
OD
SLEN
D/t
8.000
1948.00
3596.33
243.50

L/D
1.8462

Factor A
0.0001852

B
18.52

PV Elite 2015 Licensee: SPLM Licensed User


FileName : Tank 1000 L
External Pressure Calculations :
Step:

11:28pm

Page 2 of 3
Jun 27,2016

EMAP = (4*B)/(3*(D/t)) = (4*18.5166 )/(3*243.5000 ) = 101.3853 KPa.


Elliptical Head From 30 to 40 Ext. Chart: CS-2 at 35 C

Elastic Modulus from Chart: CS-2 at 35 C

: 0.200E+09 KPa.

Results for Maximum Allowable External Pressure (MAEP):


Tca
OD
D/t
Factor A
B
8.000
1948.00
243.50
0.0005704
57.03
EMAP = B/(K0*D/t) = 57.0257/(0.9000 *243.5000 ) = 260.1981 KPa.
Results for Required Thickness (Tca):
Tca
OD
D/t
Factor A
B
4.992
1948.00
390.19
0.0003560
35.59
EMAP = B/(K0*D/t) = 35.5876/(0.9000 *390.1855 ) = 101.3351 KPa.
Check the requirements of UG-33(a)(1) using P = 1.67 * External Design
pressure for this head.
Material UNS Number:

K02700

Required Thickness due to Internal Pressure [tr]:

= (P*D*Kcor)/(2*S*E-0.2*P) Appendix 1-4(c)


= (169.213*1932.0001*0.999)/(2*137.90*1.00-0.2*169.213)
= 1.1839 + 1.0000 = 2.1839 mm.
Max. Allowable Working Pressure at given Thickness, corroded [MAWP]:

= ((2*S*E*t)/(Kcor*D+0.2*t))/1.67 per Appendix 1-4 (c)


= ((2*137.90*1.00*8.0000)/(0.999*1932.0001+0.2*8.0000))/1.67
= 684.186 KPa.

Maximum Allowable External Pressure [MAEP]:


= min( MAEP, MAWP )
= min( 260.20 , 684.1862 )
= 260.198 KPa.
Thickness requirements per UG-33(a)(1) do not govern the required
thickness of this head.
External Pressure Calculations

|
|
Section |
Outside | Corroded |
Factor |
Factor |
From| To |
Length |
Diameter | Thickness |
A
|
B
|
|
|
mm.
|
mm.
|
mm.
|
|
N./mm
|
--------------------------------------------------------------------------10| 20|
No Calc |
1948.00 |
8.00000 | 0.00057039 |
57.0257 |
20| 30|
3433.67 |
1948.00 |
8.00000 | 0.00019434 |
19.4300 |
30| 40|
No Calc |
1948.00 |
8.00000 | 0.00057039 |
57.0257 |
External Pressure Calculations

|
|
External |
External | External |
External |
From| To | Actual T. | Required T.|Des. Press. |
M.A.W.P. |
|
|
mm.
|
mm.
|
KPa.
|
KPa.
|
---------------------------------------------------------------10| 20|
9.00000 |
5.99250 |
101.325 |
260.198 |
20| 30|
9.00000 |
8.85605 |
101.325 |
106.387 |
30| 40|
9.00000 |
5.99250 |
101.325 |
260.198 |
Minimum
106.387

PV Elite 2015 Licensee: SPLM Licensed User


FileName : Tank 1000 L
External Pressure Calculations :
Step:

11:28pm

Page 3 of 3
Jun 27,2016

External Pressure Calculations

|
| Actual Len.| Allow. Len.| Ring Inertia | Ring Inertia |
From| To | Bet. Stiff.| Bet. Stiff.|
Required |
Available |
|
|
mm.
|
mm.
|
cm**4
|
cm**4
|
------------------------------------------------------------------10| 20|
No Calc |
No Calc |
No Calc |
No Calc |
20| 30|
3433.67 |
3596.33 |
No Calc |
No Calc |
30| 40|
No Calc |
No Calc |
No Calc |
No Calc |

Elements Suitable for External Pressure.


PV Elite is a trademark of Intergraph CADWorx & Analysis Solutions, Inc. 2015