Sie sind auf Seite 1von 16

NECA 331 Figures

Figure 3.1(c). Grounding of AC Power System

Figure 3.1(d). Service Equipment Grounding Connections

Figure 3.3. Cable to Steel or Cast Iron Connections

Figure 3.2. Ground Clamp on Water Pipe

NECA 331 Figures

Figure 3.4(a). Foundation Rebar Ground Connection

Figure 3.4(d). Copper Wire as Concrete-Encased Electrode

Figure 3.4(e). Welded Connections for Direct Soil Burial


Figure 3.4(b). Rebar Embedded in Concrete

Figure 3.4(g). Jumper for Rebar Mat


Figure 3.4(c). UFER Ground Detail

NECA 331 Figures

Figure 3.4(h). Bonding of Anchor Bolts to Rebar

Figure 3.6. Ground


Rod with Wire Pigtail

Figure 3.6.1(g). Splice Methods for Ground Rods


Figure 3.5. Cable Connecting to Ground Ring

NECA 331 Figures

Figure 3.6.1(j). Screw/Welded Coupling for Ground Rod

Figure 3.6.2(b). Exothermic Welded Connections Made


with Multi-Use Molds

Figure 3.6.2(a). Exothermic Welded Connections Made


with Single-Use Molds

NECA 331 Figures

Figure 3.7(a). Trench Installation with Ground Enhancement Material

Figure 3.7(b). Ground Rod Installation with Ground Enhancement Material

NECA 331 Figures

Figure 3.7(c). Building Exterior Grounding Detail

Figure 4.1.1. Triad Ground Rod Details

Figure 4.1.2. Waterstop

Figure 3.7(d). Chemical Rod

Figure 4.1.3(a). Plastic Pipe for Inspection Well

NECA 331 Figures

Figure 4.1.4. Prefabricated Wire Mesh

Figure 4.1.3(b). Clay Pipe for Inspection Well

Figure 4.2(a). Grounding of Gates

Figure 4.1.3(c). Commercial Box for Inspection Well

Figure 4.2(b). Flexible Jumper with Exothermic Welded


Connection

Figure 4.1.3(d). Disconnect with Lugs

Figure 4.2(c). Exothermic Welded Connection

NECA 331 Figures

Figure 4.2(d). Bonding of Barbed Wire


Figure 4.3(e). Lighting Pole Grounding

Figure 4.2(f). Typical Perimeter Fence Isolation Detail

Figure 4.3(g). Rail Siding Grounding

Figure 4.3(h). Water Pipe Bonding


Figure 4.3(a). Pull Box Cover Grounding

NECA 331 Figures

Figure 5.1.5(a). Building Steel Grounds

Figure 5.1.5(b). Grounding Bars Welded to Steel Column

NECA 331 Figures

10

Figure 5.1.5(c). Expansion Joint Bonding Detail

Figure 5.1.5(d). Bar Joist Bonding Detail

Figure 5.1.5(e). Structural Footer Bonding Detail

Figure 5.1.5(f). Grounding System Routing

NECA 331 Figures

11

Figure 5.1.5(g). Grounding Bar Placement

Figure 5.1.5(h.1). Flush Floor Grounding Plate

Figure 5.1.5(h.2). Equipment Grounding Plate at Concrete


Column

NECA 331 Figures

12

Figure 5.1.5(k). Light-Duty Grounding Provisions

Figure 5.1.5(i). Prefabricated Grounding Plates

Figure 5.1.5(l). Conductive Floor Ground Detail

Figure 5.1.5(j). Grounding Plate on Stem Welded to Column

NECA 331 Figures

13

Figure 5.1.5(o). Metal Handrail Grounding

Figure 5.1.5(m). Bonding of Metal Doors and Frames

Figure 5.2.2(a). Motor Grounding Detail

Figure 5.1.5(n). Cable Rack Grounding

Figure 5.2.2(c). Removable Ground Detail

NECA 331 Figures

14

Figure 5.2.2(d). Bonding Steel Cable Tray

Figure 5.3. Wall-Mounted Ground Bus

Figure 5.2.2(e). Bonding Aluminum Cable Tray


Figure 5.3(a). Floor-Mounted Ground Bus

Figure 5.2.3. Recommended Receptacle Mounting Positions

NECA 331 Figures

Figure 5.3(b). Grounding Installed Around Doorways

Figure 5.3.(c) Grounding Bar Wall-Mounted

15

NECA 331 Figures

Figure 6.2(k). Ground Connection Plate in SRG

16

Das könnte Ihnen auch gefallen