Beruflich Dokumente
Kultur Dokumente
EAV8363900
www.schneider-electric.com
A IMPORTANT INFORMATION /
The information provided in this documentation is only for simple installation instruction.
Complete general specifications, installation, maintenance and safety instructions are described in the product
User Manual (EIO0000002073).
(EIO0000002074)
B PACKAGE CONTENTS /
1
1. Panel / x 1
2. DC power connector / x 1
3. Screw installation fasteners /
HMIGXU35 x 4HMIGXU55 x 6
4. Installation instruction (this instruction) /
() x 1
NOTE: Check all the applicable items listed here, if anything was broken please contact your supplier.
C INSTALLATION /
C1
C2
100
3.94
mm
in.
100
3.94
100
3.94
100
3.94
100
3.94
30
Storage temperature /
Relative humidity /
0...50 C (32...122 F)
-20...60 C (-4...140 F)
<90 % Non condensing /
DANGER /
HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH
p Disconnect all power from all equipment including connected devices, prior to
removing any covers or doors, or installing or removing any accessories, hardware,
cables, or wires except under the specific conditions specified in the appropriate
hardware guide for this equipment.
p Always use a properly rated voltage sensing device to confirm the power is off
where and when indicated.
p Replace and secure all covers, accessories, hardware, cables, and wires and
confirm that a proper ground connection exists before applying power to the unit.
p Use only the specified voltage when operating this equipment and any associated
products.
p
p
en
Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel.
No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this material.
Printed in
zh
1/3
HMIGXU35pp/55pp
www.schneider-electric.com
C3 Installation cut-out /
C
A
R
Model /
1
mm
HMI GXU35pp 190 0.04
(7.48
in)
1
255
mm
HMI GXU55pp
(10.040.04 in)
C (Panel thickness / R
)
1370,7 mm
(5.310.03 in)
185+1 mm
(7.28+0.04 in)
1...5 mm
(0.04...0.19 in)
1...5 mm
(0.04...0.19 in)
3 mm
(0.12 in) max.
3 mm
(0.12 in) max.
0,8 Nm
(7.08 lb-in)
1. Installation panel /
2. Hook /
Model /
HMIGXU35pp
HMIGXU55pp
NOTICE /
BROKEN ENCLOSURE
Do not exert more than 1 Nm (8.85 lb-in) of torque when tightening the fasteners
screws.
1 Nm (8.85 lb-in)
2
1. USB mini B downloading port / USB mini B
2. USB Type A extension port locker for HMIGXU3512 and HMIGXU5512
USB Type A HMIGXU3512HMIGXU512
3. USB Type A Extension port for HMIGXU3512 and HMIGXU5512
USB Type A HMIGXU3512HMIGXU512
4. Ethernet port for HMIGXU3512 and HMIGXU5512
HMIGXU3512HMIGXU5512
5. Serial Interface RS-422/485 / RS-422/485
6. Serial Interface RS-232C for HMIGXU3512 and HMIGXU5512
RS232C HMIGXU3512HMIGXU5512
7. Power supply connector /
+
FG
Connection Wire
+
24 Vdc
0 Vdc
Grounded terminal
FG
connected to the
panel chassis.
Pin Connection
9
Male
Pin
1
2
3
4
5
6
7
8
9
Shell
RS-232
CD
RD(RXD)
SD(TXD)
ER(DTR)
SG
DR(DSR)
RS(RTS)
CS(CTS)
Reserved
FG
RS-422/RS-485
RDA
RDB
SDA
SG
SDB
FG
Pin Connection
Female
Pin
1
2
3
4
5
6
7
8
Signal
TD+
TDRD+
RD
NOTICE /
EQUIPMENT DAMAGE
Only use 24 Vdc to power on the panel.
Do not share the power supply together with inductive load (magnet valve
or magnet switch) or I/Os of controller. 24 Vdc output from some controllers
do not have the capacity of current to power the panel
24 Vdc
24 Vdc
EAV83639 00
12 - 2014
2/3
HMIGXU35pp/55pp
www.schneider-electric.com
1
HMIGXU55pp
2
Proposed battery maintenance
period is 3 years
3
F PRECAUTIONS /
After checking the wiring route carefully, make sure to use this product with FG connected.
FG
Grounding
Use an exclusive grounding wire with a grounding resistance of 0.1 or less and a wire of 2 mm2 (AWG 14) or thicker, or your countrys applicable standard.
No sunlight/Ultraviolet
No chemical cleanser
H RoHS INFORMATION /
O:
X:
EAV83639 00
12 - 2014
SJ/T11363-2006
SJ/T11363-2006
3/3