Thecontroversialtopicofisolationrequirementandallthosequestionsthat
comeswithit:
IsitsufficienttoisolatetheactiveconductorsonlyinAlternatingCurrent
(AC)system?
DoesneutralrequiretobeisolatedinACsingleorthreephasesystems?
DoyouhavetoisolatebothnegativeandpositiveinDCsystem?
Regardlessofinwhichcountrywepractice,usaselectricalengineersmusttake
thismatterseriously.TheanswerisnotasimpleYesorNo.Assessmentmustbe
donecasebycase.IwilltakeyouthroughnumberofNationalandinternational
standardstofurtherclarifythematter.Hopefullythiswillshedsomelighton
isolationimplicationinourindustry.
InthisarticleIwillmainlyfocusonroleofNeutralconductorforisolation
purposes.Ingeneraltheintentof"neutral"conductoristoprovideareturnpath
fortheunbalancedportionofthecircuitcurrentandalsoinsomecasesa
protectiveearthlingsystem.

https://www.linkedin.com/pulse/electricalisolationrequirementneutralwirefaraz

1/20

2/18/2016

ElectricalIsolationRequirementandNeutralWire|FarazMirzaaghaMIEAustCPEngNER|LinkedIn

ACSystem
Toisolateadevice/plantitisstatedinAustralianStandard(AS3000)andIEC
60364,allactiveconductorsofanACshallbecapableofbeingisolated.
Nowthequestionisthis:WhatisanActiveconductor?
TheactiveconductorisdefinedasAnyconductorthatismaintainedata
differenceofpotentialfromtheneutralorearthedconductor.Inasystemthat
doesnotincludeaneutralorearthedconductor,allconductorsshallbe
consideredtobeactiveconductors.ThisisquiteclearbutwhataboutNeutral?
Weallseenneutralbecomeactive(figurativelyspeaking).
Nowtherearetwoscenarios,oneisyoudonotswitchtheneutralduringisolation
andtheotherwhenyoumay.Notewhenitcomestoswitchingitislefttoyou
decideasperyoursystemconfiguration.
A)NotswitchingtheNeutral
1.Iftheconductorsuppliesthemain(distributiontransformerorsimilar)
2.Iftheneutralactasprotectiveearthandneutral(PEN),someofyoumay
knowitasTNC.ThisalsoappliestoTNCSsystemwherepartofthesystem
usesacombinedPENconductor,whichatsomepointwillsplitupinto
separatePEandNlines.ThissystemalsoknownasProtectiveMultipleEarth
(PME)inUKandMultipleEarthedNeutral(MEN)inAU,seefigurebelow.

OneofthereasonweusePME/MEN
systemistoreducetheriskofelectric
shockintheeventofabrokenPEN
conductor.Lookingattheleftschematic,if
yourisolationdevice(e.g.CB)isonthered
lineyoucanarguetheprotectiveearthis
notbrokenduringisolationalthoughyou
isolatedtheneutral.

Soaslongasthatneutralisgroundedatonepointanditisusedasaprotective
earthlingattheloadend,wearenotpermittedtoswitchit.
B)SwitchingtheNeutral

https://www.linkedin.com/pulse/electricalisolationrequirementneutralwirefaraz

2/20

2/18/2016

ElectricalIsolationRequirementandNeutralWire|FarazMirzaaghaMIEAustCPEngNER|LinkedIn

IfyouhavenotsatisfiedtheconditionsaboveinsectionA,youmaynow
operateyourNeutralconsideringbelowfactorsapply:
1.Iftheneutralconductorisconnectedtoamultipoleswitch/breakeralong
withotheractiveconductors.Thatswitchshallhaveappropriateshortcircuit
breakingandmakingcapacity.Allpolesarelinkedtogetherintheswitch
whereallactiveandtheneutralconductorareoperatedatthesametime.
2.Iftherearemultipleswitcheswithoneneutralswitchortheneutralswitchis
physicallyseparatetoitscorrespondingactiveswitch.Youmayoperatethat
neutralswitchaslongasneutralcontactcannotremainopenwhentheactive
contactsareclosed.
Youmayoperatetheneutralpoleiftheneutralisoperatedatthesametimewith
othercorrespondingactiveconductorsoriftheneutralpoledoesnotopenbefore
anddoesnotcloseaftertheactivepole.Youcannowstarttoseethereasoning
behindoperatingandnotoperatingtheNeutral.
TheAustralianstandardstatesWhereanitemofswitchgearisrequiredto
disconnectallliveconductorsofacircuit,itshallbeofatypesuchthattheneutral
conductorcannotbedisconnectedorreconnectedwithouttherespectiveactive
conductorsalsobeingdisconnectedorreconnected
Floatingneutral
TheneutralshouldonlybeconnectedtogroundatonepointsuchasMEN.This
willcreateapathforcurrenttoreturntoserviceviaground.Ina3phasesystem
thegroundedneutralwillstabilizeallthreephases.Incaseofgroundbreakage
voltagepotentialwillbepresent.Similarlyifduringisolationweonlybreakthe
neutral,wewillhavefloatingneutral.Duringthisprocesswearedisturbingthe
currentpathwhichwouldreturnfromeachphasevianeutral.Inthisscenario
usuallythecurrentwillreturnviatheothertwophaseswhichresultsinvoltage
imbalance.Thisiswhenyouwillreadunexpectedhighvoltage(~100vinathree
phase415Vsystem)acrossyourEarthandNeutral,whichisquitedangerousand
unsafe.
Therearemanyreasonforfloatingneutralthemostcommonone,Iwouldsayis
sharedneutralwiring.Whereelectriciantrytosavetimeandmoney.Inbuildings
thesedaysmostelectricalequipmentarenonlinearwithcertainlevelof
harmonic(digitalworld!).Nothavingdedicatedneutralwirewillmeansallthese
currentwilladdupandreturnonsingleline.Alinethatisnotadequatelyrated
andwillleadtooverheatingandhighneutraltogroundvoltageandultimately
limitingyoursupplyvoltage.
Seebelowexampletofurtherclarifythematter.Letssaythetechnicianwould
https://www.linkedin.com/pulse/electricalisolationrequirementneutralwirefaraz

3/20

2/18/2016

ElectricalIsolationRequirementandNeutralWire|FarazMirzaaghaMIEAustCPEngNER|LinkedIn

liketoperformmaintenanceonLoadA,i.e.singlephasesupplywithNeutralwire
andlocalearth.

ThetechnicianwillisolateplantAbyopeningSwitchA.Itispossibleforthe
techniciantobeelectrocutedviaNeutralconductor.Thatcanoccurdueto
existingpotentialdifferenceorafaultatloadBwhichcreatesapotential
differencebetweendistributionboard,LoadAorLoadB.Therearemanyother
scenarioswherethereissystemvulnerability.Thesesituationsusuallywill
happeninplaceswitholdwiringandbadpracticeswheretheelectriciantryto
savetimeandmoney!
Forthesamereasonnofuseshallbeinsertedinaneutralconductor.Soincaseof
faultyouwontloseyourneutralandmaintaincontinuity.Protectivedevicesthat
incorporateaswitchingfunctionintheneutralconductorshallcomplywiththe
requirementsofsectionB.
Whataboutatransferswitch?
Neutralswitchingwouldbe'required'(bycodessuchasNECandAS),ifthetwo
sourcesareindependentlygroundedi.e.separatelyderivedsystems.Thisisto
avoidmultipleneutralgroundingandproperfunctioningofgroundfaultcurrent
sensing/protection.

Home

Profile

MyNetwork

WhatabouttheACswitchdiscounterforaPVinverter?
Searchforpeople,jobs,companies,andmore...
Advanced

Jobs

Interests

BusinessServices

TryPremiumforfree

AsperBS60947andAS,toisolatewemustswitchallliveandneutral

Pulse
ElectricalIsolationRequirement
andNeutralWire
FarazMirzaaghaMIEAust...

IsUberredefiningthework
week?
OliviaBarrow

TwoWordsThatWillKillAny
Conversation

conductors.

Publishapost

DCsystem
GenerallyspeakingboththenegativeandpositiveinDCcircuitshallbecapableof
beingisolated.Inthefollowingscenariosyoumayonlyoperateonepolefor
isolation:

https://www.linkedin.com/pulse/electricalisolationrequirementneutralwirefaraz

4/20

2/18/2016

ElectricalIsolationRequirementandNeutralWire|FarazMirzaaghaMIEAustCPEngNER|LinkedIn

Conversation
MarshallGoldsmith

ExtralowvoltageDCsystem
Whereoneofthepolesisconnectedtoearth.E.g.someUPSsystem,earthed

BigCos,NewCos,andtheNine
TrendsRemakingBusiness
JohnBattelle

WhatMostPeopleDont
UnderstandAboutHowStartup
CompaniesareValued

D.C.negativeinbatterybanksandmidpointofPVstring.
Note:earthingonepolewillincreasepossibleearthfaultpaths,andpossible
problemswithcommonlyavailableEuropeaninvertertypesandinternalearth
faultdetectioncircuitry.

MarkSuster

GivingaPresentation?Three
WaystoLeaveYourFingerprint

PowerDistribution, ElectricalEngineering,

Reportthis

SafetyEngineering

JackWelch

More"Conversations"Not
MoreHealthITAreWhat's
NeededToIncreasePatient
StephenWilkinsMPH...
EngagementAndImprove

Writtenby

FarazMirzaaghaMIEAustCPEngNER

Like

Comment

Follow

7likes 0comments

Bethefirsttocommentandstarttheconversation!

AvoidTheseRelationshipsLike
thePlague
Dr.TravisBradberry

UbersCEOsaysregulators
doomedacompanyjustlikehis
100yearsagoandhewon
ChipCutter
letithappenagain
3ReasonsNottoReadThis
ArticleonReversePsychology
A.J.Jacobs

VinoeDigitas:Understanding
Complexity
LouisD.LoPraeste

Thisyear'sgiftbagatTEDis
almostembarrassinglylarge
here'severythingitincludes
OliviaBarrow

Follow

ReporteratMilwaukeeBusinessJournal

IsUberredefiningtheworkweek?
Feb16,2016

455,226views

1,074Likes

306Comments

The9to5jobhasbeenoutofpopularityforseveralyears.Employerswhowant
toattractthetoptalentknowandtheyveknownforseveralyearsthat
theyvegottoofferflexibleschedulesasmuchaspossibleinordertoretainthe
mostindemandworkers.
https://www.linkedin.com/pulse/electricalisolationrequirementneutralwirefaraz

5/20

Das könnte Ihnen auch gefallen