MQX-Enabled MK30X256 SinglePhase Electricity Meter Reference

Design
Using the MK30X256, MC1322x, and MAG3110

Document Number: DRM122


Rev. 0

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


2

Freescale Semiconductor, Inc.

Contents
Section Number

Title

Page

Chapter 1
Introduction
1.1 Overview..........................................................................................................................................................................7
1.2 General platform features.................................................................................................................................................8
1.2.1 Hardware design features .....................................................................................................................................8
1.2.2 Software features of the design..............................................................................................................................9
1.3 MK30X256 microcontroller series...................................................................................................................................9
1.3.1 Peripheral application usage..................................................................................................................................11
1.4 1322x Low Power Node (LPN)........................................................................................................................................13
1.5 MAG3110 3-axis digital magnetometer...........................................................................................................................15

Chapter 2
Basic Theory
2.1 Definition of terms...........................................................................................................................................................17
2.1.1 Power.....................................................................................................................................................................17
2.1.2 Energy....................................................................................................................................................................19
2.1.3 Power factor...........................................................................................................................................................19
2.2 Electricity distribution......................................................................................................................................................20
2.3 Electricity meters..............................................................................................................................................................21
2.3.1 Electromechanical meters......................................................................................................................................22
2.3.2 Electronic meters...................................................................................................................................................22
2.4 Voltage and current measurement....................................................................................................................................24
2.4.1 Voltage divider......................................................................................................................................................25
2.4.2 Shunt resistor.........................................................................................................................................................26
2.4.3 Current transformer...............................................................................................................................................26
2.4.4 Rogowski coil........................................................................................................................................................28

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


Freescale Semiconductor, Inc.

Section Number

Title

Page

Chapter 3
System Concept
3.1 Application description....................................................................................................................................................29
3.1.1 Metering board.......................................................................................................................................................30
3.1.2 Switch Mode Power Supply board connection......................................................................................................33
3.1.3 External current sensor connection........................................................................................................................34
3.1.4 1322x-LPN connection..........................................................................................................................................35
3.1.5 Power meter case...................................................................................................................................................35
3.2 Application usage.............................................................................................................................................................37
3.2.1 Power meter hardware configuration.....................................................................................................................37

Chapter 4
Hardware Design of the Metering Board
4.1 Introduction to hardware implementation........................................................................................................................39
4.2 Power supply section .......................................................................................................................................................39
4.3 Digital hardware ..............................................................................................................................................................41
4.3.1 MCU core..............................................................................................................................................................41
4.3.2 RS232 interface.....................................................................................................................................................41
4.3.3 Infrared interface (IEC1107).................................................................................................................................42
4.3.4 Open collector interface.........................................................................................................................................43
4.3.5 LED interface.........................................................................................................................................................43
4.3.6 SPI interface...........................................................................................................................................................44
4.3.7 Magnetometer interface.........................................................................................................................................44
4.3.8 I2C interface..........................................................................................................................................................45
4.3.9 MRAM interface....................................................................................................................................................45
4.4 Signal conditioning ..........................................................................................................................................................46
4.4.1 Voltage measurement............................................................................................................................................46
4.4.2 DC bias connection................................................................................................................................................47
4.4.3 Shunt resistor current measurement.......................................................................................................................48
4.4.4 Zero-cross detection circuit...................................................................................................................................49

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


4

Freescale Semiconductor, Inc.

Section Number

Title

Page

Chapter 5
Application Set-Up
5.1 Setting-Up the Demo Hardware ......................................................................................................................................51
5.2 Setting up the software demo...........................................................................................................................................53
5.2.1 FreeMASTER data visualization ..........................................................................................................................53
5.2.2 ZigBee communication .........................................................................................................................................55

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


Freescale Semiconductor, Inc.

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


6

Freescale Semiconductor, Inc.

Chapter 1
Introduction
1.1 Overview
This design reference manual describes the solution for a single-phase electricity meter
based on the MK30X256 microcontroller (MCU). The design demonstrates the
capabilities of this MCU for electricity metering applications. There are also additional
Freescale components used in this design, including the RF (ZigBee) and magnetometer
solution (interface).
The reference design provides a high performance solution for power measurement in
single phase two-wire installations. The target market is residential metering. The
reference design has the ability to connect to a ZigBee network thanks to the integrated
1322x low power node, hence it can easily become part of the smart grid network.
Besides this development, this design uses the MQX real time operating system, to
improve the code structure and to serve as a proof of concept for true real-time
applications, such as a power meter. Because of the MQX, this power meter is designed
for use in advanced markets.
In addition, two measurement methods are explored, implemented, and compared in this
reference design (FFT, filter-based method). This reference design manual describes only
the hardware solution for the power meter. Software solutions, mainly metering
algorithms, are described in associated documents, like application note AN4255, FFTbased Algorithm for Metering Applications.
The power meter reference design is prepared for use in a real customer metering area, as
suggested by its implementation of a Human Machine Interface (HMI) and
communication interfaces for remote data collecting. Finally, it provides both hardware
and software solutions for customer applications.

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


Freescale Semiconductor, Inc.

General platform features

1.2 General platform features


This chapter describes the main hardware and software features of the MK30X256 Power
Meter Reference Design. See also Table D-1.

1.2.1 Hardware design features


5 (60) A current range, nominal current is 5 A, peak current is 60 A
120/230 V AC, 50/60 Hz operational range
Active and reactive power (energy) measurement
Accurate metering function for active and reactive energy: IEC50470-3 class B, 1%
Meter constants (imp/kWh, imp/kVArh): 500, 1000, 2000, 5000, 10000
Four-quadrant measurement
Line frequency measurement (for precision zero-cross detection)
Cost-effective shunt resistor sensing circuit implementation without an external
OpAmp
Voltage sensing is executed by an inexpensive resistor divider
Cost-effective bill of materials (BOM) due to low-cost hardware configuration
Low-power modes effectively implemented, including the use of a built-in real-time
clock (RTC)
3 V internal battery for proper RTC function
4 31 segment LCD, including charge pump. Values shown on the LCD: V, A, W,
VAr, VA, kWh, kVArh, cos , Hz, time, date
Object identification system (OBIS) identifier on the LCD
Tamper detection via:
Two built-in hidden buttons
3-axis MAG3110 digital magnetometer (optional)
Built-in user push-button
LED pulse outputs (kWh, kVArh)

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


8

Freescale Semiconductor, Inc.

Chapter 1 Introduction

Optically isolated open-collector pulse output


IEC1107 infrared hardware interface
Optically isolated RS232 interface (19200 Bd, 8 data bits, no parity)
JTAG debug interface (non-optically isolated)
2.4 GHz RF interface through a 1322x low power node daughter card
Powered by a 3.3 V SMPS open-frame module (3rd party solution)
All componentsboard, sensors, and switch mode power supply (SMPS)are built
into a plastic box with a transparent cover
EMC proven design (EN61000-4-2, EN61000-4-4, EN6100-4-5, EN6100-4-6,
EN6100-4-8, EN6100-4-11)

1.2.2 Software features of the design


Application C/ASM source code for IAR Embedded WorkBench is available.
MQX-based design for advanced markets.
Multiple advanced metering algorithms for precise energy measurements:
Fast Fourier Transform
Filter based method (optional only)
ZigBee SE1.0 stack implemented in 1322x low power node for connection to a
ZigBee network.
FreeMASTER visualization script for calibration, watching, and so on.

1.3 MK30X256 microcontroller series


The MK30X256 is a member of the 32-bit Kinetis family of MCUs. This family
represents the most scalable portfolio of ARM CortexTM-M4 MCUs in the industry.
Enabled by innovative 90nm Thin Film Storage (TFS) flash memory technology with
unique FlexMemory (configurable embedded EEPROM), Kinetis features the latest lowpower innovations and high performance, high precision mixed-signal capability with a
broad range of connectivity, human-machine interface, and safety & security peripherals.
The MK30X256 comes with a full suite of hardware and software tools to make
development quick and easy. There is a block diagram of this MCU in Figure 1-1.
MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0
Freescale Semiconductor, Inc.

MK30X256 microcontroller series

The MK30X256 MCU provides the following main features:


Up to 100 MHz ARM Cortex-M4 core delivering 1.25 DMIPS/MHz with DSP
instructions
Voltage range of 1.713.6 V
256 KB of program flash memory
256 KB of FlexNVM and 4 KB FlexRAM
64 KB of SRAM
16 independently-selectable DMA channels
Integrated high-precision 16-bit successive approximations register (SAR) analog-todigital converters (ADCs) with programmable gain amplifiers (PGAs)
Two integrated 12-bit digital-to-analog converters (DACs)
Programmable 1.2 V voltage reference
High-speed analog comparator with 6-bit DAC
Timers: FlexTimer, PDB, PIT, LPT, CMT, RTC
Hardware CRC module to support fast cyclic redundancy check
Hardware random-number generator
128-bit unique identification number per chip
Human-Machine Interfaces: segment LCD, touch-sensing interface, and GPIO
Communication interfaces: CAN, SPI, I2C, UART, SDHC, I2S
40 C to +105 C operating temperature range
Typical target applications of this MCU are:
Smart meters
Thermostats
Heart rate monitors
Blood gas analyzers

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


10

Freescale Semiconductor, Inc.

Chapter 1 Introduction

Figure 1-1. Kinetis MK30 family block diagram

1.3.1 Peripheral application usage


The power meter concept benefits greatly from plenty of integrated internal peripherals in
the MK30X256 MCU.
In this application, the Analog-to-Digital Controller (ADC):
Employs two channels: one is differential with an internal PGA (x32) for shunt
resistor current measurement, the second is single-ended for voltage measurement.
Includes a linear successive approximation algorithm with a 16-bit resolution.
Allows high-speed conversion (up to 128 samples per one period).
Provides a 12-MHz module clock (with 48 MHz bus clock).
Creates a proper ADC result with 16 hardware-averaged samples.
In this application, the General Purpose Input/Output (GPIO):
Directly controls some peripherals such as LEDs, open-collector, and so on.
MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0
Freescale Semiconductor, Inc.

11

MK30X256 microcontroller series

In this application, the Inter-Integrated Circuit (I2C):


Primarily provides a method for internal communication between the meter (slave)
and the 1322x-LPN daughter card (master)prepared for ZigBee communication.
Secondarily, allows internal communication with the 3-axis digital magnetometer
MAG3110 (optional only)prepared for tamper detection.
Drives interrupts with byte-by-byte data transfer.
Communicates at up to 100 kbit/s with software selectable-slave address.
In this application, the Low-Leakage Wake-up Unit (LLWU):
Allows button and tamper pins to wake the MCU from low-power mode.
In this application, the Liquid Crystal Display (LCD) controller:
Allows up to 320 segments (4 31 is currently used).
Displays data.
In this application, the 16-bit FlexTimer Module (FTM):
Allows a free-running mode with interrupt.
Generates precision time marks for zero-crossing.
In this application, the Comparator Module (CMP):
Compares the input voltage signal with a bias voltage (reference).
Allows interrupts on rising edges.
Generates capture flags for zero-cross voltage signal detection. Due to this, a variable
time window for the PDB is generated.
Measures line frequency.
In this application, the Programmable Delay Block (PDB):
Allows hardware triggering of the ADC channels.
Provides two individually-controlled trigger conditions (one for each ADC channel)
depending on the phase shift of the sensors.
In this application, the Real-Time Clock (RTC):
Provides an ultra-low power independent real-time clock with calendar features
(iRTC).
In this application, the Universal Asynchronous Receiver/Transmitter (UART):
Provides a communication interface with an external PC (for calibration, watching).
Communication settings are 19200 Bd, 8 data bits, one stop bit, and no parity.
Provides communication interface for the IEC1107 infrared communication port
(optional).
MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0
12

Freescale Semiconductor, Inc.

Chapter 1 Introduction

In this application, the Serial Peripheral Interface (SPI):


Provides a communication interface with the MRAM (optional).
In this application, the Voltage Reference (VREF):
Provides a reference voltage for internal analog peripherals such as the ADC and
CMP.
Uses a low-power buffer mode.

1.4 1322x Low Power Node (LPN)


The 1322x-LPN is one of the Freescale 1322x development kits designed for connecting
to a ZigBee network. The 1322x low power node is designed as a stand-alone
development board, including an MC1322x, two LEDs, two push buttons, a GPIO
connector, header pins, and a programming and debug port. Note that the ZigBee
capabilities of this board are only used in the MK30X256 metering concept; because of
this feature, the power meter can easily become part of the smart grid. The Low Power
Node board is internally connected to an MK30X256 metering board through an I2C
interface. Here are the main features of the 1322x low power node board:

2.4 GHz wireless nodes compatible with the IEEE 802.15.4 standard
Based on the MC13224V Platform in a Package (PiP)
Hardware acceleration for both the IEEE 802.15.4 MAC and AES security
Printed F antenna
Over-the-air data rate of 250 kbit/s
Typical range (outdoors, line of sight) is 300 meters
Onboard expansion capabilities for external application-specific development
activities
Programmable flash memory
JTAG port for reprogramming and in-circuit hardware debugging
Buttons and LEDs for demonstration and control
Connections for battery or external power supply

The core of the 1322x low power node is the Freescale MC1322x 99-pin LGA Platformin-Package (PiP) solution that can be used for wireless applications ranging from simple
proprietary point-to-point connectivity to complete ZigBee mesh networking. The
MC1322x is designed to provide a highly-integrated, total solution, with premier
processing capabilities and very low power consumption. A full 32-bit ARM7TDMI-S
core operates up to 26 MHz. The RF radio interface provides for low cost and high
density as shown in Figure 1-2.

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


Freescale Semiconductor, Inc.

13

1322x Low Power Node (LPN)

Figure 1-2. MC1322x RF interface

As described above, the 1322x low power node is used for connecting an MK30X256
power meter to a ZigBee network. ZigBee, an IEEE 802.15.4 standards-based solution, as
defined by ZigBee Alliance, was developed specifically to support sensing, monitoring,
and control applications. The ZigBee solution offers significant benefits, such as low
power, robust communication, and a self-healing mesh network. The ZigBee solution
frequencies are typically in the 868/915 MHz or 2.4 GHz spectrums.
The ZigBee data rate for technology solutions is 250 Kbps. ZigBee technology
theoretically supports up to 65,000 nodes. Common applications in sensing, monitoring,
and control, which are best supported by a ZigBee technology solution include:

Personal and medical monitoring


Security, access control, and safety monitoring
Process sensing and control
Heating, ventilation, and air conditioning (HVAC) sensing and control
Home, building, and industrial automation
Asset management, status, and tracking
Fitness monitoring
Energy management
NOTE
For connection of the power meter to a ZigBee network via the
1322x-LPN daughter card, it is necessary to program the
1322x-LPN with the correct firmware. That description is
beyond the scope of this design reference manual.

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


14

Freescale Semiconductor, Inc.

Chapter 1 Introduction

1.5 MAG3110 3-axis digital magnetometer


The MAG3110 is a small, low-power, digital 3-axis magnetometer. It features a standard
I2C serial interface output and smart embedded functions. The device can be used in
conjunction with a 3-axis accelerometer to produce orientation-independent, accurate
compass heading information.
The MK30X256 metering concept is prepared for tamper detection or any illegal opening
of the power meter's cover. However, the tamper function using a 3-axis I2C
magnetometer is optional.
The MAG3110 provides the main following features:

1.953.6 V supply voltage (VDD)


1.62 VVDD IO voltage (VDDIO)
Ultra small 2 2 0.85 mm DFN 10-pin package
Full scale range 1000 T
Sensitivity of 0.1 T
Noise down to 0.25 T rms
Output Data Rates (ODR) up to 80 Hz
I2C digital output interface (operates up to 400 kHz fast mode)
7-bit I2C address = 0x0E
Sampled low power mode
RoHS compliant

Typical applications for this magnetometer are:


Electronic compass
Dead-reckoning assistance for GPS backup
Location-based services
There is a simplified magnetometer functional block diagram in Figure 1-3.

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


Freescale Semiconductor, Inc.

15

MAG3110 3-axis digital magnetometer

Figure 1-3. Simplified magnetometer functional block diagram

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


16

Freescale Semiconductor, Inc.

Chapter 2
Basic Theory
2.1 Definition of terms
This section defines basic terms of electricity metering theory.

2.1.1 Power
AC power flow has three components: real power (P) measured in watts (W), apparent
power (S) measured in volt-amperes (VA), and reactive power (Q) measured in reactive
volt-amperes (VAr).
Active power (P), also known as real or working power, is the power that actually powers
the equipment. As a rule, true power is a function of a circuit's dissipative elements,
usually resistances (R).

Reactive power (Q) is a concept used by engineers to describe the loss of power in a
system arising from the production of electric and magnetic fields. Although reactive
loads such as inductors and capacitors dissipate no power, they drop voltage and draw
current, creating the impression that they actually do. This imaginary power or nonworking power is called reactive power (Q). If the load is purely inductive or capacitive,
then the voltage and current are 90 degrees out of phase (for a capacitor, current leads
voltage; for an inductor, current lags voltage) and there is no net power flow. This energy
flowing backwards and forwards is known as reactive power. Reactive power is thus
produced for system maintenance and not for end-use consumption. By convention, a
"lagging," or inductive load, such as a motor, will have positive reactive power. A
"leading," or capacitive load, has negative reactive power. Reactive power is a function
of a circuit's reactance (X).

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


Freescale Semiconductor, Inc.

17

Definition of terms

Apparent power (S) is the vector summation of active and reactive power. It is the
product of a circuit's voltage and current, without reference to phase angle. Apparent
power is a function of a circuit's total impedance (Z).

These three types of powertrue, reactive, and apparentrelate to one another in a


trigonometric form. This is called a power triangle (see Figure 2-1). The opposite angle is
equal to the circuit's impedance (Z) phase angle. Apparent power is often computed from
this power triangle using the Pythagorean Theorem as:

Figure 2-1. Power triangle

A common utility system is often based on total apparent power (Stot) measured also in
volt-amperes (VA). Total apparent power is a product of the RMS voltage and RMS
current, and is defined as:

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


18

Freescale Semiconductor, Inc.

Chapter 2 Basic Theory

This a general proposition:


In a pure sinusoidal system with no higher harmonics, the apparent power (S) equals Stot.
If there are some higher harmonics in the line, apparent power is not the same as total
apparent power, because the simple vector sum in apparent power computing is less
accurate. Therefore, Stot is often used because it is more precise in these situations.

2.1.2 Energy
Energy is the accumulated power over a period of one hour.
Active energy means the electrical energy produced, flowing, or supplied by an electric
circuit during a time interval, being integral with respect to time of the instantaneous
active power and measured in units of watt-hours (Wh). For practical use in power
meters, a higher unit called a kilowatt-hour (kWh) is used, which is 1000 watt-hours
(Wh).
Apparent energy means the integral with respect to time of the apparent power. Kilovoltampere-hour (kVAh) is the unit for total (apparent) energy.
Reactive energy means the integral with respect to time of the reactive power. Kilovoltampere-reactive-hour (kVArh) is the unit for reactive (non-working) energy.

2.1.3 Power factor


The power factor of an AC electric power system is defined as the ratio of real power
flowing to the load to the apparent power in the circuit, and is a dimensionless number
between 0 and 1 (frequently expressed as a percentage, that is 0.5 pf = 50% pf). Real
power is the capacity of the circuit for performing work in a particular time. Apparent
power is the product of the current and voltage of the circuit. Due to energy stored in the
load and returned to the source, or due to a nonlinear load that distorts the wave shape of
the current drawn from the source, the apparent power will be greater than the real power.
In an electric power system, a load with a low power factor draws more current than a
load with a high power factor for the same amount of useful power transferred. The
higher currents increase the energy lost in the distribution system and require larger wires
and other equipment. Because of the costs of larger equipment and wasted energy,

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


Freescale Semiconductor, Inc.

19

Electricity distribution

electrical utilities usually charge a higher rate to industrial or commercial customers


where there is a low power factor. Therefore, a modern electronic smart power meter
must also measure the power factor.
Power factor is defined as:

is the phase angle between voltage and current.


When power factor is equal to 0, the energy flow is entirely reactive. Stored energy in the
load returns to the source on each cycle. When the power factor is 1, all the energy
supplied by the source is consumed by the load. Power factors are usually stated as
leading or lagging to show the sign of the phase angle. It is often desirable to adjust the
power factor of a system to near 1.0.

2.2 Electricity distribution


Electricity distribution is the final stage in the delivery of electricity to end users. A
distribution system's network carries electricity from the transmission system and
delivers it to consumers. Part of what determines the design of the electricity meter is the
transmission supply design, the most common residential arrangements being:
1-phase, 2 wire (1P2W) Europe and Asia 220 V-240 V, US 2-wire 110 V
1-phase, 3 wire (1P3W) US 3-wire, sometimes called 2-phase
3-phase, 4 wire (3P4W)
The 1-phase 2-wire installation is the most common form of electricity distribution in the
world. Finally, more than 80% of the population in the world uses a 1-phase 2-wire
installation of 230 V/50 Hz (see at Figure 2-2). Much of the US installation is 110 V/60
Hz 1-phase 2-wire. The electricity meter described in this design reference manual is
designed for use in 1P2W installations.

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


20

Freescale Semiconductor, Inc.

Chapter 2 Basic Theory

Figure 2-2. Residential voltage and frequency worldwide

2.3 Electricity meters


An electric meter or energy meter is a device that measures the amount of electrical
energy consumed by a residence, business, or an electrically powered device. Electric
meters are typically calibrated in billing units, the most common of which is the kilowatt
hour (kWh). Periodic readings of electric meters establish billing cycles and energy used
during a cycle.
A kilowatt hour is equal to the amount of active energy used by a load of one kilowatt
over a period of one hour, or 3,600,000 joules. Some electricity companies use the SI
megajoule instead. Similarly to active energy in kWh, there is also reactive energy
(kVArh) and apparent energy (kVAh). See Section 2.1.2 Energy .
Electricity meters operate by continuously measuring the instantaneous voltage (volts)
and current (amperes) and finding the product of these to give instantaneous electrical
power (watts) which is then integrated against time to give energy used (joules, kilowatthours, and so on.). Meters for smaller services (such as small residential customers) can
be connected directly in-line between source and customer. For larger loads of more than
about 200 amps, current transformers are used so that the meter does not have to be
located in-line with the service conductors.
Standard electricity meters fall into two basic categories, electromechanical and
electronic.

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


Freescale Semiconductor, Inc.

21

Electricity meters

2.3.1 Electromechanical meters


The most common type of electricity meter is still the electromechanical induction watthour meter. These meters will be progressively substituted by fully electronic meters
because of their many additional advantages (see Section 2.3.2 Electronic meters).
The electromechanical induction meter operates by counting the revolutions of an
aluminium disc that is made to rotate at a speed proportional to the power. The number of
revolutions is proportional to the energy usage. It consumes a small amount of power,
typically around 2 watts.
The metallic disc is acted upon by two coils. One coil is connected in such a way that it
produces a magnetic flux in proportion to the voltage, and the other produces a magnetic
flux in proportion to the current. The field of the voltage coil is delayed by 90 degrees
using a lag coil. This produces eddy currents in the disc and the effect is such that a force
is exerted on the disc in proportion to the product of the instantaneous current and
voltage. A permanent magnet exerts an opposing force proportional to the speed of
rotation of the disc. The equilibrium between these two opposing forces results in the disc
rotating at a speed proportional to the power being used. The disc drives a register
mechanism that integrates the speed of the disc over time by counting revolutions, much
like the odometer in a car, to render a measurement of the total energy used over a period
of time.

2.3.2 Electronic meters


Electronic meters display the energy used on an LCD or LED display, and can also
transmit readings to remote places. In addition to measuring energy used, electronic
meters can also record other parameters of the load and supply such as maximum
demand, power factor, reactive power used, and so on. They can also support time-of-day
billing, for example, recording the amount of energy used during on-peak and off-peak
hours.
A typical electronic power meter has a power supply block, a signal conditioning circuit,
a metering engine (AFE), a processing and communication engine (that is, a
microcontroller), and other add-on modules such as RTC, LCD, communication ports and
modules, and so on. For a basic block outline of the electronic power meter, see Figure
2-3.

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


22

Freescale Semiconductor, Inc.

Chapter 2 Basic Theory

User
Selection

voltage
current

analog
Signal
Conditioning

AFE

digital

MCU

ADC

LCD

AMR
Communications
Figure 2-3. Basic outline of the electronic power meter

The signal conditioning circuitry is used for adapting a high-amplitude signal from the
line to a lower one accepted by the Analog Front End (AFE) and Analog-to-Digital
Converter (ADC).
The metering engine is given the voltage and current inputs, has a voltage reference,
samplers, and quantizers followed by an ADC section to yield the digitized equivalents of
all the inputs. All of this is sometimes called the Analog Front End (AFE). These inputs
are then processed using a DSP or MCU to calculate the various metering parameters
such as powers, energies, and so on.
The processing and communication section has the responsibility of calculating the
various derived quantities from the digital values generated by the metering engine. This
also has the responsibility of communication using various protocols and interfaces with
other add-on modules connected as slaves.
RTC and other add-on modules are attached as slaves to the processing and
communication section for various input and output functions. On a modern meter, most,
if not all, of this is implemented inside the microprocessor, such as the Real Time Clock
(RTC), LCD controller, temperature sensor, memory, and analog-to-digital converters.
One of the important features of the modern electronic power meter is automatic meter
reading (AMR) technology. AMR is the technology of automatically collecting
consumption, diagnostic, and status data from energy metering devices and transferring
that data to a central database for billing, troubleshooting, and analyzing. This advance
mainly saves utility providers the expense of periodic trips to each physical location to
MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0
Freescale Semiconductor, Inc.

23

Voltage and current measurement

read a meter. Another advantage is that billing can be based on near real-time
consumption rather than on estimates based on previous or predicted consumption. This
timely information, coupled with analysis, can help both utility providers and customers
to better control the use and production of electric energy. Electronic meters with AMR
technology can read and communicate through several mechanisms such as:

Infrared
Radio frequency
Data modem (via a telephone line)
Power line carrier
Serial port (RS-485)
Broadband

AMR meters often have sensors that can report the meter cover opening, magnetic
anomalies, extra clock setting, stuck buttons, inverted installation, reversed or switched
phases, and so on. These events may be immediately sent to the utility company thanks to
AMR technology.
Smart meters go a step further than simple AMR. They offer an additional function,
including a real-time or near real-time reading, power outage notification, and power
quality monitoring. They allow price setting agencies to introduce different prices for
consumption based on the time of day and the season. The feedback they provide to
consumers has also been shown to cut overall energy consumption.
In comparison to the traditional mechanical or electromechanical power meter solution,
the electronic meters offer the utility market several additional advantages including:

Improved immunity and reliability


Higher accuracy
Higher security
Support of a wide range of power factor loads
Easier calibration
Anti-tampering protection, including traditional or modern solutions
Automated meter reading (AMR)
Advanced billing methods (prepay, time-of-use, and so on)

2.4 Voltage and current measurement


In electricity meters, the energy is calculated from two measured signals, voltage and
current. For line voltage and line current measurement, systems that are generally called
sensors are used. Whichever sensor is used, voltage and current measurements result in
an AC voltage with a magnitude proportional to the signal being measured.
MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0
24

Freescale Semiconductor, Inc.

Chapter 2 Basic Theory

The voltage sensor results in a sine wave with a fundamental frequency of typically either
50 or 60 Hz depending upon the power distribution used. See Section 2.2 Electricity
distribution.
For current measurement, the sensor provides a fundamentally sinusoidal signal (possibly
with harmonics), which may lag or lead the voltage signal depending upon the load.
A typical simplified configuration for metering voltage and current in a 1-phase 2-wire
installation is shown in Figure 2-4. There are three typical sensors used for sensing
current and voltage in power meters. All of these sensors are also used in the electronic
power meter described in this manual.

Figure 2-4. Typical measurement circuit in 1P2W installation

The following sections describe the commonly used methods for sensing the voltage and
current used in electronic power meters.

2.4.1 Voltage divider


A voltage divider is used for voltage measurement. In a practical implementation,
multiple series resistors are used instead of R1 to limit the power dissipation and reduce
the heat generated, thus improving accuracy. See Figure 2-4.
The equation for computing output voltage of the voltage divider is defined as:
MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0
Freescale Semiconductor, Inc.

25

Voltage and current measurement

Where Vin is the phase voltage and Vout is the voltage measured by the ADC (voltage
drop at R2).
The voltage divider can be selected to more closely meet the specification of the ADC.

2.4.2 Shunt resistor


A shunt resistor is used to sense the current because it does not distort the signal and it
costs less than other current measurement methods. The downside of using a shunt
resistor is primarily the power dissipation that can create inaccuracies in the measurement
due to resistive changes, and due to temperature and the waste of power. To limit the selfheating effect of the shunt, the resistor is made using a metal with suitable properties. The
resistance of the shunt is kept very low to reduce power dissipation.
Typically, shunt resistors are in the range of 100300 , and as such, the voltage
developed across them is very small. For example, 100 A drawn through a 200 shunt
develops only 20 mV (voltage = current resistance). Through a 300 shunt, this
would be 30 mV, which entails 2 W power loss and 3 W, respectively.
The problem with this approach is the very small voltages derived from the shunt resistor
and the even smaller resolution of valid measurements. Therefore, a signal derived from
the shunt resistor must be amplified to keep the correct measurement precision.
Operational amplifiers are frequently used for this purpose in most applications, but the
MK30X256 power meter uses an internal PGA for this.
There are several rules for the right selection of a shunt resistor in the application:
A shunt resistor must have good thermal properties (that is, Manganin alloy with a
low temperature coefficient of resistance).
The shunt size must be selected to maximize the dynamic range of the ADC input.
The shunt resistor must be selected to minimize power dissipation.
NOTE
Power dissipated by the shunt resistor, plus the power supply
used by the meter, must be below the specification for the meter
(IEC1036 specifies a 2 W/10VA total power loss).

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


26

Freescale Semiconductor, Inc.

Chapter 2 Basic Theory

2.4.3 Current transformer


Current transformers (CT) are used extensively for measuring current and monitoring the
power grid. Like any other transformer, a current transformer has a primary winding, a
magnetic core, and a secondary winding. The alternating current flowing in the primary
produces a magnetic field in the core, which then induces a current in the secondary
winding circuit, as in Figure 2-5. The CT is typically described by its current ratio (N)
from primary to secondary. Relative to current output of the CT, it is necessary to use an
external current to a voltage converter, such as a burden resistor Rb (see Figure 2-4), in
systems where the voltage input of the ADC is used in the majority of applications. The
primary objective of the current transformer design is to ensure that the primary and
secondary circuits are efficiently coupled, so that the secondary current bears an accurate
relationship to the primary current.
The benefits of using a CT are that the output voltage can easily be matched to the
capability of the ADC input by selecting the appropriate winding or appropriate burden
resistor (Rb), and because of this, an external OpAmp is not necessary. Another important
benefit of using a CT is that this sensor isolates the measuring engine from the line;
therefore, the CTs may be easily used in polyphase meters.
A typical feature of a CT is the time shift between the primary and secondary currents in
the windings. For using this in the power meters, it is good to know that the power meters
must wait a specific time after the voltage measurement before reading the current from
the CT. The delay required is specific to each CT, and is established during calibration of
the meter and programmed into the meter, as a part of the calibration constants.
CT coils have the negative effect of distorting the current measurement. Considering the
magnetic core of the CT, it is necessary to respect a maximum recommended current in
the primary winding (rating factor) because of saturation of its core. A good accuracy in
the case of CT current measurement is directly related to other factors, including external
electromagnetic fields and a change of temperature.

Figure 2-5. Current transformer principle


MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0
Freescale Semiconductor, Inc.

27

Voltage and current measurement

2.4.4 Rogowski coil


A Rogowski coil is an electrical device for measuring alternating current (AC) or highspeed current pulses. It consists of a helical coil of wire with the lead from one end
returning through the centre of the coil to the other end, so that both terminals are at the
same end of the coil, as in Figure 2-6. The whole assembly is then wrapped around the
straight conductor whose current is to be measured. Because the voltage that is induced in
the coil is proportional to the rate of change (derivative) of current in the straight
conductor, the output of the Rogowski coil is usually connected to an electrical, or
electronic, integrator circuit to provide an output signal that is proportional to the current.
One advantage of a Rogowski coil over other types of current transformers is that it can
be made open-ended and flexible, allowing it to be wrapped around a live conductor
without disturbing it. Because a Rogowski coil has an air core rather than an iron core, it
has a low inductance and can respond to fast-changing currents. Also, because it has no
iron core to saturate, it is highly linear even when subjected to large currents, such as
those used in electric power transmission, welding, or pulsed power applications. A
correctly formed Rogowski coil with equally spaced windings is largely immune to
electromagnetic interference.
The benefits of using a Rogowski coil are similar to using a CT; namely, the output
voltage can more easily be matched to the capability of the ADC input by selecting an
appropriate winding, load resistor, and filter. Another advantage of a Rogowski coil is
that it costs less than a traditional CT, although it requires an integrator and additional
phase compensation.

Figure 2-6. Rogowski coil principle

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


28

Freescale Semiconductor, Inc.

Chapter 3
System Concept
3.1 Application description
A standard system block diagram of the MK30X256 power meter concept is shown in
Figure 3-1. The full-metering system solutionthat is, all the components within the
outer black-dashed rectangleincorporates the following parts:
Metering board (inside the diagram's inner black-dashed rectangle). The main
metering engine, this is the concentrated majority of metering components.
Switch Mode Power Supply boardv(SMPS). This board is used for supplying the
metering engine and the 1322x-LPN daughter card.
External current sensor (shunt resistor). Located directly at the line power connector
inside the metering case.
1322x-LPN. Daughter card for ZigBee communication.
Power meter case with an integrated line power connector and an RS232
communication connector.
Some common parts of the power meter in the block diagram have the same color for
better function identification. The voltage signal conditioning and current sensor, for
instance, are colored red. See Figure 3-1. There is one current sensor in the power meter
(shunt resistor), that is located near the line power connector inside the terminal
compartment of the power meter case, outside the metering board. There is a voltage
measurement signal conditioning part (voltage divider) that is located directly on the
metering board.

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


Freescale Semiconductor, Inc.

29

Application description

Figure 3-1. MK30X256 power meter block diagram

3.1.1 Metering board


The metering engine (board) is the main part of the power meter. It is comprised of
components such as the MCU with the AFE, signal conditioning part, LCD, button,
LEDs, optical interface for the IEC1107 and RS232, voltage signal conditioning, tamper
button, 3 V battery, magnetometer, and some communication connectors. The metering
board is designed on a two-sided printed circuit board. Most of the components are
soldered on its top side (see Figure 3-2), while some components are soldered on the
bottom side of the printed circuit board (see Figure 3-3).

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


30

Freescale Semiconductor, Inc.

Chapter 3 System Concept

RS232
interface
Display
LED KWh

LED KVArh
OC interface
MRAM

Battery

Tamper 1

MCU

JTAG interface
User Button

Magnetometer
interface

Crystal
Infrared
interface

Shunt
interface

VBIAS
selection

User LED
Mains
interface

Voltage
conditioning part

Tamper 2 interface
Power supply interface

Figure 3-2. Metering board, top view

RS232
interface

OC
interface

Current
conditioning part

I2C
interface

SPI
interface

Figure 3-3. Metering board, bottom view


MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0
Freescale Semiconductor, Inc.

31

Application description

The core of the metering engine placed on the top side of the board is the MK30X256, a
32-bit ARM Cortex-M4 MCU. (For a description, see Section 1.3 MK30X256
microcontroller series.) All of the MCU peripherals used in the application, except for the
JTAG interface, are pictured in the block diagram in Figure 3-1.
A simplified function of the MCU in the application is as follows:
The ADC, which is a part of the MCU, reads data from voltage and current sensors. The
MCU computes other values such as powers, energies, power factor, and line frequency
consecutively. Moreover, the MCU communicates with the user through the built-in HMI
(LCD and button) or several communication interfaces (RS232, ZigBee, IEC1107, LEDs,
OC). A description of the metering algorithm is beyond the scope of this design reference
manual, but is described in application note AN4255, FFT-based Algorithm for Metering
Applications.
The HMI of this power meter is comprised of the following parts: an LCD, a push-button,
and one (red) LED. The LCD displays plenty of computed values, such as the RMS value
of line voltage and current, powers, energies, power factor, line frequency, and also the
actual time and date. The push-button allows you to select one of these values to be
shown on the LCD.
NOTE
There is only one main value shown on the LCD at a time.
The next important part of the metering engine board is signal conditioning. This part is
used for adapting the signal level from sensors to the AFE (part of the MCU including the
ADC and PGA). There are two different types of signal conditioning with regards to
sensors used: the part for voltage measurement is made of a simple voltage divider. The
part for current measurement via a shunt resistor is made from a simple resistor bridge,
which is used for shifting the signal on the shunt above 0 V. Thanks to the internal PGA,
no external operational amplifier is needed.
There are several communication interfaces on the metering board. The interface for
RS232 is optically isolated by optocouplers, and the interface for the IEC1107 is optically
isolated by infrared components. The open-collector is an optically-isolated output of the
power meter; this may be used for switching some small loads. One of the most
interesting types of communication in this power meter is RF or ZigBee. Communication
through RF/ZigBee is accomplished by the external 1322x-LPN daughter card (outside
the metering engine), which communicates with the metering board through the I2C
interface. Finally, two red LEDs are used for optical communication with the utility
service provider. This is the energy output interface; the first LED here is for active
energy counting and the second LED is for reactive energy counting.

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


32

Freescale Semiconductor, Inc.

Chapter 3 System Concept

The essential parts of the metering board are components for the proper functioning of
the MCU's real-time clock (RTC), including the 3 V battery (for saving date and time)
and crystal. Two hidden tamper buttons recognize any illegal opening of the cover or
terminal compartment section of the meter, one soldered directly on the metering board,
and the second outside of the board in the terminal compartment section.
The power meter also offers another method of tamper detection through the use of a 3axis I2C magnetometer (the MAG3110 silicon may be used for this). The MK30X256
power meter does not currently use this type of tamper detection; however, the interface
for it is now prepared. An illegal cover opening can cause a 3-axis motion that is detected
by the magnetometer and interpreted as an illegal opening by an algorithm sophisticated
enough to distinguish it from the ordinary motions of the meter. But this type of operation
is optional, since the tamper push-buttons are used for tamper detection.

3.1.2 Switch Mode Power Supply board connection


The SMPS board is used for supplying the metering board engine. The SMPS used in this
application is a 3rd party open-frame solution for the power supply that produces one
galvanic-isolated level of output voltage. This open-frame SMPS module has a wide
range of input AC voltages (85264 V, RMS) with a wide range of line frequencies (47
63 Hz) as well. Thanks to these input parameters of the SMPS, the whole power meter
can work with line voltages and frequencies in these ranges. The output voltage is fixed
to a 3.7 V DC level with a 1.16 A nominal output current and a power rating of 4.3 W.
Figure 3-4 provides an overview of the board. There are two power connectors on this
board: on the left side there is an input socket for connection to the mains (L_inp, N_inp),
and on the right side there is an output socket for supplying the board. The SMPS is
housed in the left part of the power meter case (under the metering board) and connected
to the line and metering board by two thin cables.

+3.7V

N_inp
L_inp

GND

Figure 3-4. SMPS Board View

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


Freescale Semiconductor, Inc.

33

Application description

NOTE
Default output voltage level for this type of SMPS is 3.3 V.
Other output voltage levels are adjusted by small trimmer on
the SMPS board (in the 3.03.6 V range, approximately) or by
adding an SMD resistor in parallel to the output voltage divider
on the SMPS board (27 k for +3.7 V).

3.1.3 External current sensor connection


The MK30X256 power meter uses a shunt resistor as the external current sensor for
phase current measurement.
The shunt resistor is specifically a Manganin resistor of an accurately known resistance,
in this case 300 . This shunt resistor is intended for current measurement of up to 60
A RMS. The voltage drop across the shunt resistor is proportional to the phase current
flowing through it; because its resistance is known, a small voltage drop is amplified by
the internal PGA of the MCU, and then measured by the internal ADC of the MCU. For a
photo of the shunt resistor, see Figure 3-5. The terminal connection of this shunt resistor
is divided into two partspower connection and sense connectionand because of this,
a 4-wire current measurement may be done. The power connection is intended for a
connection between the phase input (L_inp) and phase output (L_out) connectors. The
sense connection of this shunt resistor is intended only for measuring its voltage drop.
LINE_IN LINE_OUT

GND

L_inp

L_out

Figure 3-5. Shunt resistor description

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


34

Freescale Semiconductor, Inc.

Chapter 3 System Concept

NOTE
There is also a separated ground terminal (GND) in the sense
connection area for the metering board ground connection. This
ground terminal is located on the same side as the power phase
input (L_inp).

3.1.4 1322x-LPN connection


The 1322x-LPN is intended for use as a ZigBee node for the power meter. It works as an
intermediator between the power meter and a ZigBee coordinator, which is based at the
utility provider area, for example. The ZigBee coordinator scans data from various
equipment (power meter, home thermostat, sensor, dimmer switch, and so on) in the
ZigBee network and sends it to the central (PC) station. The 1322x Low Power Node is
screwed onto the bottom part of the power meter case, near the SMPS, and connected as a
daughter card to the metering engine through a thin flat cable. The board overview is in
Figure 3-6. There are two pairs of wires for connection to the metering board: the first
pair is for supplying the node (3.3 V, GND), and the second pair is for the I2C
communication lines (SCL, SDA).
I2C connections

Power
connection
arrea

Figure 3-6. 1322x-LPN board view

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


Freescale Semiconductor, Inc.

35

Application description

3.1.5 Power meter case


All the components mentioned (boards, sensor, and so on) are housed in a power meter
case. This is made as a base with transparent main and terminal compartment covers. It is
intended primarily for mounting in a vertical position (on a wall, for example) by three
screws. Because of the transparent cover, the metering board with the main components,
including the LCD primarily, are easily visible.

Metering Board

Flat cable +
RS232 connector

Neutral
1322x-LPN
daughter card

Phase output
Phase input
Shunt Resistor

Mounting hole
Mounting hole
SMPS

Figure 3-7. Power meter case, inside view

Figure 3-7 shows a photo of the metering case without either of the transparent covers.
You can see the boards and the current sensor placements. There are also four power
terminals in the terminal compartment section; the first is for phase input, the second is
for phase output, and the remaining two terminals are for neutral connections. The main
metering board is mounted onto four plastic columns (spacers) on the front side of the
power meter case. On the left side of the case, there is the SMPS, and on the bottom side
of the case there is the 1322x-LPN daughter card. The shunt sensor is soldered directly
between the two left power terminals, namely the phase input (L_inp) and the phase
output (L_out). On the right side of this case, there is an RS232 connector, which is
connected to the main board by a thin 9-pin flat cable.

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


36

Freescale Semiconductor, Inc.

Chapter 3 System Concept

3.2 Application usage


3.2.1 Power meter hardware configuration
The MK30X256 power meter is pictured in Figure 3-8. This power meter is primarily
intended to demonstrate the MCU in a single-phase, two-wire installation. For a better
practical demonstration of the power meter, it is placed on a perspex base with an outlet
(for load connection) and a cable with a plug (for connection to the power line). The
whole configuration, shown in Figure 3-9, is also called the power meter demo.
Active energy LED

Display

Reactive energy LED

RS232 connector
Open-collector output
Battery

Tamper button 1 (hidden)


User button

User LED

Tamper button 2 (hidden)


Terminal compartment

Figure 3-8. Power meter view

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


Freescale Semiconductor, Inc.

37

Application usage

Pedestal

Metering
engine

Outlet
Terminal
compartment

Cable with plug

Figure 3-9. Power meter demo view

Although the current range of this power meter is internally set for a measurement of up
to 60 A, for practical use this range is reduced to approximately 16 A, adequate for
demonstration purposes. This is due to a maximum current rating of the outlet and the
plug used. For those who want to use the entire metering range of up to 60 A, both the
plug and outlet must be replaced by more powerful ones.
For remote data communication, either the RS232 port or the in-built ZigBee node may
be used .
NOTE
An open-collector communication interface is not directly
accessible.You must first open the cover of the case to access
its connections.

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


38

Freescale Semiconductor, Inc.

Chapter 4
Hardware Design of the Metering Board
4.1 Introduction to hardware implementation
This chapter describes the design of the application hardware, that is, the design of the
metering board (engine). The main hardware is divided into two main parts, digital
hardware (HW) and analog hardware. Analog hardware is also called signal conditioning
in this manual. Digital hardware is configurable depending on the customer request, from
a low-cost solution to a high-performance (full) configuration. The stand-alone section of
the metering board is the power supply section, and this is a mandatory part of each
configuration of the power meter.
With regards to various digital hardware configurations, there are also various power
meter configurations. These power meter configurations are differentiated:
Full power meter configuration. For a schematic view, see Figure A-1. For layout
views, see Figure B-1 and Figure B-2. For the BOM, see Table C-1.
Low-cost power meter configuration with only the necessary components. For a
schematic view, see Figure A-2. For layout views, see Figure B-3 and Figure B-4.
For the BOM, see Table C-2.

4.2 Power supply section


The power supply section is used mainly for adapting the voltage level from the external
SMPS (3.7 V) to the internal board, and also includes the overvoltage protection (see
Figure 4-1). The 3 V battery is also a part of the power supply section; it is used for
supplying the MCU in case of a power outage. Connector J4 placed on the bottom side of
the printed-circuit board is the input power supply connector of the board. This connector
must be joined to the external SMPS; that is, pin 2 of connector J4 to 3.7 V on the SMPS
and pin 1 of the connector J4 to the GND of the SMPS.

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


Freescale Semiconductor, Inc.

39

Power supply section

As you can see, there is a simple overvoltage protection including the Zener diodes D12
and D13. These diodes protect against a reversal of polarity.
The power supply section of the metering board produces four power supply levels for
individual blocks of the metering board:

VDDMCUdigital voltage 3.3 V for the MCU only


VDDAMCUanalog voltage 3.3 V for the MCU only (for AFE)
VDDdigital voltage 3.7 V for all peripherals
VDDAanalog voltage 3.7 V for the DC bias circuit only

Some circuits in the design require two separated power supply levels, a digital and an
analog power supply. The analog power supply level of the MCU is separated from its
digital power supply by the chip inductor L2 with cooperation of filters C45C47. The
analog power supply level of the DC bias circuit is separated from the digital part of the
power supply by the chip inductor L1 with cooperation of filters C37C39. Power supply
levels for the peripherals and for the MCU are separated by diode D11. Because of this,
the peripherals are not powered in the case of a power outage (in this case, only the MCU
is powered, via the 3 V battery). The voltage drop on this diode is approximately 0.4 V;
therefore, analog and digital voltage levels for peripherals are far above this voltage level
in comparison to voltage levels at the MCU.
There are two separated grounds in the design, a digital ground (GND) and an analog
ground (GNDA). Both of these grounds are joined together through the chip inductor
marked L3 in the schematic.
1uH

C37
VDD

B
A

C39

BT1

GNDA

2
1

C38

0.1UF 10UF 100PF

BATTERY

GND

1
3V

CON_2_TB

GND GND

C40
47UF

GND

GND
TP13

VDD

C41
0.1UF

GND

TP15
GNDA

BAT54CLT1

C42
100PF

TP10

TP17

3.3V VDDMCU
3

VDDAMCU

GND

VDDA

D11

3V

3.6V
D12

MMSZ5231BT1G

J4

SJ2 2 PAD JUMPER

VDDA

L1

1
C43

C44

L2

L3
1
MMSZ5231BT1G

R31
47K

D13

0.1UF 10UF

R30
10K

1uH

1uH

3.3V
C45

C46

0.1UF

100PF

GNDA
TP12

VDDMCU

GND

47UF

TP11

VDDAMCU

TP14

TP16

VCC_PRESENT

+ C47

GNDA

Figure 4-1. Power supply part of the metering board

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


40

Freescale Semiconductor, Inc.

Chapter 4 Hardware Design of the Metering Board

The presence of an external power supply level (from the SMPS) is shown through a
simple voltage divider (R30, R31) in the power supply section. Logic 0 on the
VCC_PRESENT pin means there is a power outage. In this case, the metering board is
supplied from the internal 3 V battery, and the software causes a power down for most of
the MCU peripherals.
NOTE
The peripheral supply voltage level on the metering board is the
same as that of the external SMPS. The MCU supply voltage
level is consequently lower around the voltage drop on diode
D11.

4.3 Digital hardware


4.3.1 MCU core
The MCU is the core of the metering board. It is marked as U1 in the schematic. The
MCU core, with all key components, is displayed in both Figure A-1 and Figure A-2. For
the MCU to function correctly, several components are necessary:
Filters C2C8, C10C12, C19
RC filter for resetting the MCU, including R20 and C16
Crystal Y1 with filters C20 and C21
Another part of the the MCU core, which we may simply assign to it, is the Human
Machine Interface (HMI). This includes components such as the display DS1 and the user
push-button SW1, with the simple filter C23. There is one tamper button, SW2, on the
board, and connector J5 for connecting the second tamper which is placed in the terminal
compartment section. Pull-up resistors for the button and tampers are software selectable
by the MCU; therefore, no external pull-ups on the board are needed. The charge pump
for the LCD is a part of the MCU. Therefore, the LCD requires minimal external
componentsin fact, only capacitors C28, C31, C32, and C33.
Connector J1 is the JTAG interface for MCU programming. Be careful about
programming the MCU through this interface in a configuration where the power meter
demo is fed from the line. This interface is not isolated from the line, and an electric
shock can arise. To prevent this, use an external optically isolated JTAG interface.

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


Freescale Semiconductor, Inc.

41

Digital hardware

4.3.2 RS232 interface


This interface is used primarily for a basic set-up of software for the meter, including
calibration, checking sensor outputs, and visualization. Communication is optically
isolated through optocouplers ISO1 and ISO2. Because two additional signals are used on
the serial data line, RTS and DTR, the secondary side of ISO1 and the primary side of
ISO2 are powered from the RS232 data line (from the PC side). These signals are
normally used for transmission control, but this function is not used in the application. As
there is a fixed voltage level on the control lines, it may be used to supply the
optocouplers, in cooperation with other components. These components include D6, D7,
D9, C15, R19, and R13. The part of the schematic including the RS232 communication
interface can be seen in Figure 4-2.
ISO1
2

(+12V)

390

D6

ISO2

2.2UF
+

3
RS232_TXD
RS232_RXD

C15

2
R19
470

1 1
SFH6106-4

D9

J8

D7
1

SFH6106-4

MMSD4148T1G

4
2

R16
1.0K

RTS

R13
4.7K

VDD

MMSD4148T1G

R12

RXD
TXD
DTR
GND

1
3
5
7
9

2
4
6
8
10
CON_2X5

MMSD4148T1G

GND

Figure 4-2. RS232 communication interface of the metering board

4.3.3 Infrared interface (IEC1107)


This interface uses infrared components, the high efficiency IR emitting diode D10, and
the NPN phototransistor Q1. Both of these are through-hole assembled. Apart from these,
some necessary passive components are used, such as R27, R28, R29, and C36. The part
of the schematic including the IEC1107 communication interface can be seen in Figure
4-3.

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


42

Freescale Semiconductor, Inc.

Chapter 4 Hardware Design of the Metering Board


IR_TX
IR_RX

TP8
VDD

TSAL4400

GND

D10

OP506B
2

0.1UF

Q1

GND

C36

R28
22K
R29
1.0K

TP9

R27
680.0

GND

Figure 4-3. IEC1107 part of the metering board

4.3.4 Open collector interface


The open collector interface portion of the schematic can be seen in Figure 4-4. This is a
galvanic-isolated interface thanks to optocoupler ISO3. It may be used for switching
some small loads with a maximum collector-to-emitter voltage of VCEO of up to 70 V,
and a maximum collector current of up to 50 mA. Output from this interface is accessible
on connector J6.
ISO3
2
R23

EOC_OE 1
390

1
EOC

EOC_OC 2

VDD

CON_2_TB
B
A
J6

4
SFH6106-4

Figure 4-4. Open collector interface of the metering board

4.3.5 LED interface


The two high-efficiency LEDs in this part are used for energy counting: D2 for active
energy counting and D1 for reactive energy counting. They are used primarily for
calibration of the meter; the number of flashes of the LEDs is proportional to total
accumulated energy, that is, the sum of import and export energy. Both of these LEDs are
through-hole assembled for a better placement near the cover. The final LED used in this
part of the schematic is the user LED D3, which may be used for detecting some program
states, for example. Each of these LEDs is lit by logic 0 from the MCU. The part of the
schematic including the LED interface can be seen in Figure 4-5.

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


Freescale Semiconductor, Inc.

43

Digital hardware
D1
C
A
R2
390
WP7104LSRD
D2
C
A
R3
390
WP7104LSRD
D3
C
A
R8
390
LED RED

LED_kVarh

LED_kWh

LED_USR

VDD

Figure 4-5. LED part of the metering board

4.3.6 SPI interface


The SPI interface is optional. It is not used at this time, but it has been prepared for future
usage. It is connected to the MCU by the 6-pin header J9. Apart from the supply voltage,
all the SPI data lines are connected (SOUT, SIN, CLK and CS) . The part of the
schematic including the SPI communication interface can be seen in Figure 4-6.
C22
VDD
SPI2_CS0
SPI2_SCK
SPI2_SOUT
SPI2_SIN

5
3
1

J9

0.1UF
6
4
2

GND

HDR 2X3

Figure 4-6. SPI interface part of the metering board

4.3.7 Magnetometer interface


The magnetometer function in this power meter is described in detail in Section 3.1.1
Metering board. The section of the schematic including the magnetometer interface can
be seen in Figure 4-7. In this schematic, the magnetometer is marked as U3. The
magnetometer may be used in this power meter for tamper detection (optional) instead of
the standard button.The magnetometer communicates with the MCU through I2C data
lines; therefore, external pull-ups R25 and R26 on the SDA and SCL lines are required.
The magnetometer uses the same I2C data lines as the 1322x-LPN daughter card;
therefore, the software selectable addresses of both of these peripherals are required
(done by the MCU).
NOTE
Because of very the small supply current of this chip, it may be
powered directly through the GPIO pin of the MCU (see
VDDMAG net in the schematic).

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


44

Freescale Semiconductor, Inc.

Chapter 4 Hardware Design of the Metering Board


VDDMAG
C24
1UF

8
VDDIO

CAP_A
CAP_R
NC

SCL
SDA
INT1

GND1

GND

1
4

GND2

C30
0.1UF

0.1UF

GND

7
6

I2C1_SCL
I2C1_SDA

INT1
TP7

MAG3110

10

C29
0.1UF

U3

VDD

GND

C27

C26
0.1UF

GND

Figure 4-7. Magnetometer interface part of the metering board

4.3.8 I2C interface


The I2C interface is used for joining the 1322x-LPN daughter card and the MCU. This
daughter card is used primarily for RF/ZigBee communication. The 1322x-LPN board is
connected by a thin flat cable directly to the 6-pin header J7 of the metering board. Pullups for I2C data lines are required (R25, R26). It is better to use hardware pull-ups than
software configurable pull-ups inside the MCU. A schematic of the connection between
the metering engine and the daughter card can be seen in Figure 4-8.
1322x-LPN
1
I2C_SDA
3
5
7
9
11

J1

2
4 I2C_SCL
6
8
10
12

90122-12
BC1
GND

2468

2xAAA Cells
1 +3.3V
+

C25

VDD
R25
4.7K

R26
4.7K

5
3
1

0.1UF

J7

6
4
2

HDR 2X3

GND

Metering board

Figure 4-8. Interface between 1322x-LPN and the metering board

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


Freescale Semiconductor, Inc.

45

Signal conditioning

4.3.9 MRAM interface


The MR25H10 (U2 in the schematic) is a 1-Mbit magnetoresistive random access
memory (MRAM) device organized as 131072 words of 8 bits. The MR25H10 offers
serial EEPROM and serial flash memory compatible read/write timing with no write
delays and unlimited read/write endurance. It allows the use of more data memory in the
application than the standard MCU can offer. Using this memory in the design is
optional, because the capacity of the internal SRAM of the MCU is enough for most
applications. The section of the schematic including the MRAM interface can be seen in
Figure 4-9. The MRAM communicates with the MCU through a standard SPI interface.
NOTE
Because of the very small active read/write current of this chip,
it may be powered directly through the GPIO pin of the MCU
(see VDDMRAM net in the schematic).
VDDMRAM

U2
5
SPI0_SOUT
SPI0_SCK
SPI0_CS0
MRAM_CTRL
SPI0_SIN

6
1
3

VDD
SI

SO

SCK

WP
VSS

HOLD

C13
0.1UF

MRAM

CS

MR25H10CDC

GND

EXP

9
GND

Figure 4-9. MRAM interface part of the metering board

4.4 Signal conditioning


4.4.1 Voltage measurement
There is a simple voltage divider used for the line voltage measurement in Figure 4-10.
This is a basic and key part of each configuration of the power meter. In the basic block
diagram (see Figure 3-1), there is a voltage divider, based on two simple resistors. In a
practical implementation it is better to design this divider from several resistors
connected serially due to the power-loss spread. One half of this total resistor consists of
R5, R7, R9, and R11, the second half consists of resistor R6. The basic voltage divider
described produces a sine voltage signal around ground. This is not acceptable for the
ADC, because all voltage signals connected to it must be above ground (single-ended
configuration). Therefore, a further voltage divider that raises the signals is added to the
connection. This second divider is made from R4 and R6 (a part of the line divider). The
MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0
46

Freescale Semiconductor, Inc.

Chapter 4 Hardware Design of the Metering Board

ratio of this second divider allows a voltage on the ADC input from 01.2 V (Vref). The
sine voltage signal from the line is then shifted to Vref 2; that is, approximately 0.6 V.
See Figure 4-10.
V_BIAS

RS1
20S0271

CON_2_TB

D4

GND

4.7K

R9
100K
R11
100K
R5
220K
R7
220K

R10
47

0.6V+/-0.5V

BAV99LT1
1

TP2

R4
1
1

J2

VDDAMCU

R6
1K

GNDA

V_OUT

C9
1000pF

LPF CUTOFF
3.4MHz

Figure 4-10. Voltage signal conditioning part of the metering board

Finally, there is a simple RC low-pass filter (R10 + C9) at the end of the voltage divider.
The cut-off frequency for that is set to 3.4 MHz according to this relation:

NOTE
Some components in the voltage measurement part of the
schematic are depicted for a 3.7 V DC bias supply net. For a 1.2
V DC bias supply voltage level, see the resistors selection in
Figure 4-11.

4.4.2 DC bias connection


The DC bias voltage (V_BIAS net in the schematic) is used for supplying some circuits
in the analog signal conditioning parts. These parts are: a voltage divider in the voltage
measurement section, a resistor bridge in the current measurement section, and a zerocross detection circuit. The correct DC bias voltage is selected by the SJ1 jumper on the
board, which assigns one of the following power nets to V_BIAS:
3.7 V (VDDA) analog peripheral supply voltage net (default configuration used in
the schematic)
1.2 V (VREF_OUT) reference output of the MCU

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


Freescale Semiconductor, Inc.

47

Signal conditioning

Because of the different voltage levels of individual configurations, some resistors in


relevant blocks must be reconfigured, particularly R4, R6, R11, R22, R24. The part of the
schematic including the jumper for the DC bias selection and the right resistor selection
table is in Figure 4-11.
NOTE
The 1.2 V reference output of the MCU is powerful enough to
supply all analog peripherals of the MK30X256 power meter
which are tied on the V_BIAS net.

SJ1
3

VREF_OUT

V_BIAS

VDDA

SJ1
1-2
2-3
R4 4K7 2K2
R6 1K
2K2
R11 100K 220K
R22 4K7 4K7
R24 1K
4K7

Figure 4-11. DC bias circuit and resistors selection

4.4.3 Shunt resistor current measurement


Because there is a very small voltage drop at the shunt resistor, the drop must be
amplified before it is processed in the ADC. This operation is carried out by an external
operational amplifier mostly, though in the MK30X256 power meter it is possible to use
the internal PGA. The upshot of this solution is obvious: the designed power meter might
be cheaper in comparison to a traditional one that uses an external OpAmp. Since the
voltage drop at the shunt is around ground, and the internal PGA accepts voltages above
ground, the voltage drop on the shunt must be shifted above ground. A simple resistor
bridge is used for this. The bridge is made from resistors R14, R15, R17, and R18. The
original zero voltage level is then shifted to 75 or 25 mV, respectively, depending on the
correct DC bias voltage (for selection, see Section 4.4.2 DC bias connection). Differential
output of this resistor bridge (L_DP, L_DN) is joined directly to an analog pin (PGA0) of
the MCU. Finally, two protection diodes D5 and D8 are used. These diodes, in
conjunction with half of the resistor bridge (R14, R18), protect inputs of the MCU against
spikes from the line. The schematic of the shunt resistor current measurement block is in
Figure 4-12.
NOTE
Filter capacitor C14 should be placed as close as possible to the
chip inputs (see the layout in the Appendix section). This
requirement is also valid for filter C9 in the voltage section.
MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0
48

Freescale Semiconductor, Inc.

Chapter 4 Hardware Design of the Metering Board

BAV99LT1
2

VDDAMCU

CON_2_TB
A

LINE_OUT

LINE_IN

R14
100
R18
100

GNDA

TP3
D5 25mV+20.4mV
75mV+20.4mV
R15
4.7K
R17
4.7K
25mV-20.4mV
D8 75mV-20.4mV

L_DP
C14

V_BIAS
220PF
L_DM

TP4

BAV99LT1

B
J3

GNDA

VDDAMCU

Figure 4-12. Shunt resistor signal conditioning part of the metering board

4.4.4 Zero-cross detection circuit


The MK30X256 power meter can measure the line frequency. In order to do so, the zerocrossing of the input line voltage must be measured. The main principle for doing this is
to compare output voltage from the voltage conditioning part (see Section 4.4.1 Voltage
measurement) with a known voltage level (the DC bias voltage in this case). This is done
by the analog comparator (CMP) of the MCU. The first input of this comparator is
connected to the DC bias voltage through a voltage divider that divides the DC bias
voltage to 0.6 V, and the second input of the comparator is joined to the line through a
voltage divider (V_OUT net in the schematic). The part of the schematic including the
zero-cross detection circuit can be seen in Figure 4-13. For proper operation of the analog
comparator, there should be also two filters, C17 and C18.
NOTE
Some components in the schematic of the zero-cross detection
circuit are depicted for a 3.7 V DC bias supply net. For a 1.2 V
DC bias supply voltage level, see the resistors selection in
Figure 4-11.
CMP2_IN0
C17

R21
10K

V_OUT

100PF
GNDA R22
CMP2_IN1 0.6V
4.7K
C18
R24
1K
0.1UF

V_BIAS

GNDA

Figure 4-13. Zero-cross detection circuit

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


Freescale Semiconductor, Inc.

49

Signal conditioning

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


50

Freescale Semiconductor, Inc.

Chapter 5
Application Set-Up
5.1 Setting-Up the Demo Hardware
The following section is focused on setting up the metering demo hardware.

Mains 120/230V
50/60 Hz

PHASE
NEUTRAL

NEUTRAL
PHASE

Load up to 60 A

Figure 5-1. Power meter line connection

Connect the power meter directly to the line (see Figure 5-1).
Connect an external load to the power meter (see Figure 5-1).
For a better practical demonstration of the power meter, the metering case may
alternatively be placed on an acrylic base with an outlet (for a load connection) and a
cable with a plug (for connection to the power line). The whole configuration is also
called the power meter demo (see Figure 3-9).

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


Freescale Semiconductor, Inc.

51

Setting-Up the Demo Hardware

After connecting the power meter to the line, the display turns on and shows the last
value that was there before turning it off. Apart from the main value, the display
shows the other symbols (see Figure 5-2), such as OBIS codes, tamper identifiers,
actual tariff, and unit (regarding the main value).
You can also select other values to be shown on the display by pressing the pushbutton. The following is a list of these values:
Table 5-1. Power meter display values
Value

Units

Format

OBIS code

Line voltage

VRMS

0.01V

32.7.0

Line current

ARMS

0.001A

31.7.0

Signed active power

0.1W (+ forward, - reverse)

1.7.0

Signed reactive power

VAr

0.1VAr (+ lag, - lead)

3.7.0

Apparent power

VA

0.1VA

9.7.0

Power factor

0.0001

13.7.0

Active energyimport

kWh (Wh)

0.0001kWh, 0.01Wh, 0.001Wh

1.8.0

Active energyexport

kWh (Wh)

0.0001kWh, 0.01Wh, 0.001Wh

2.8.0

Reactive energyimport

kVArh (VArh)

0.0001kVArh, 0.01VArh, 0.001VArh

3.8.0

Reactive energyexport

kVArh (VArh)

0.0001kVArh, 0.01VArh, 0.001VArh

4.8.0

Frequency

Hz

0.001Hz

14.7.0

Time

hour,min,sec

HH:MM:SS

0.9.1

Date

year,month,day

YYYY:MM:DD

0.9.2

SW version

x.x.x

0.2.0

All of the energies (four counters) are saved into the non-volatile memory. These
energies remain in memory after resetting the power meter. To clear the energy
counters, you must use the FreeMASTER application (see Section 5.2.1
FreeMASTER data visualization ) and apply a Clear Energies command.
There are two tampers hidden under the cover. When you remove the cover, tamper
symbol(s) is/are shown on the LCD. These symbols remain on the LCD even after a
reset, because this information is saved in the non-volatile memory. To clear the
tamper status you must use the FreeMASTER application (see Section 5.2.1
FreeMASTER data visualization ) and apply a Clear Tampers command.
When you push the user button during power-on, the LCD shows the actual version
of the internal software.
Both energy LEDs flash simultaneously with the internal energy counters. This
means that flashes of each energy LED are proportional to the sum of import and
export energy (active or reactive).
A 3-V battery is used for the proper RTC function.
RS232 plug is used for FreeMASTER data visualization and calibration.
MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0
52

Freescale Semiconductor, Inc.

Chapter 5 Application Set-Up

Actual tariff

Value

Tamper for device cover


Tamper for terminal cover

OBIS identifier

Unit

Figure 5-2. MK30X256 power meter display description

5.2 Setting up the software demo


The following section focuses on setting up the metering demo software.

5.2.1 FreeMASTER data visualization


For FreeMASTER data visualization, the RS232 cable between the power meter and the
PC must first be connected. The FreeMASTER visualization script is the software for
remote visualization and remotely setting up the power meter via an RS232 cable. This
software runs on the PC that connects to the power meter via an RS232 cable. The
FreeMaster visualization script is the application that runs under the FreeMASTER
software. FreeMASTER software is one of the off-chip drivers that supports
communication between a target microcontroller and a PC. This tool allows the
programmer to remotely control an application with a user-friendly graphical
environment running on a PC. It also provides the ability to view some real-time
application variables in both textual and graphical form. FreeMASTER software runs
under Windows 98, 2000, or XP. It is a versatile tool to be used for multipurpose
algorithms and applications, providing a lot of excellent features, including:

Real-time debugging
Diagnostic and visualisation tools
Demonstration tool
Educational tool

Before running a visualization script, FreeMASTER software must be installed on your


PC. After that, a FreeMASTER visualization script may be started after double-clicking
on the MK30X.pmp file in the Visualisation directory. Following this, a visualization
script will appear on your PC. For more information, see Figure 5-3.

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


Freescale Semiconductor, Inc.

53

Setting up the software demo

Figure 5-3. FreeMASTER Visualization Script (GUI)

You should set the proper serial communication port and speed in the Project/Option
menu (see Figure 5-4) now. After doing so, you must set the proper Project.out project
file in the menu Project/Option/MAPfiles (see Figure 5-5). This file is accessible in
subdirectory FLASH_256KB_PFLASH_256KB_DFLASH. If all previous settings are
correctly done, the FreeMASTER visualization script for the power meter is now
prepared for running. To do this, you must click on the Start/Stop Communication button.
At this time, you can see the voltage and current diagrams in the time domain and in the
frequency domain (in an FFT window) too. You may also see other variables in a textual
format, such as frequency, VRMS, IRMS, energies, and so on.
Alternatively, you may set some values, such as an impulse number, clock and date, and
so on. After setting the appropriate value in the column cell, use the right command for
transferring this value to the meter's RAM. Only the following commands are allowable:
clock setting, impulse number setting, clear energies, clear tampers. After application of
these commands, it is also suitable to use the flash save command to save these values
into a non-volatile memory of the MK30X256. You are not allowed to change "red"
values in the Calibration section of the FreeMASTER visualization script, because of the
loss of calibration constants. These values include: voltage and current gain, voltage
phase delay, and power offset.

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


54

Freescale Semiconductor, Inc.

Chapter 5 Application Set-Up

NOTE
All system (FreeMASTER) values are saved automatically
during meter power-down. Therefore, the flash save command
doesn't have to be used.

Figure 5-4. FreeMASTER communication port setting

Figure 5-5. FreeMASTER project file setting

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


Freescale Semiconductor, Inc.

55

Setting up the software demo

5.2.2 ZigBee communication


ZigBee communication is optional and is not implemented in every power meter demo.
There is a 2.4 GHz 1322x-LPN daughter card inside the power meter. The ZigBee
module and the power meter are connected through the I2C. For joining the power meter
to the ZigBee network, you will need the 1322x-SRB module, which is like a ZigBee
coordinator (see Figure 5-6). The power meter can now easily become part of a smart
grid.

Figure 5-6. 1322x-SRB as a ZigBee coordinator

The following is a standard communication procedure for joining the power meter to a
smart grid:
Install the latest version of the BeeKit from the Freescale web page. There is also a
ZeD monitor as a separate part of the BeeKit. Use the ZeD monitor for
demonstrating ZigBee communication between the power meter and the PC.
Switch the power meter on and connect a load to it.
Connect the ZigBee coordinator (1322x-SRB) to the PC with a USB cable and
switch the coordinator on. The coordinator must be powered. To do this, plug the AC
adaptor to the coordinator (you may also use the internal battery inside the
coordinator module), or use a USB power line from the PC side (this is the best
choice). You will have to install the software driver for this equipment after the first
connection of the 1322x-SRB to the PC. The driver is on the CD in the
Drivers \LuminaryFTDI directory, or alternatively on the Future Technology Devices
International (FTDI) web page.
Push the SW1 button on the coordinatorit looks up all ZigBee equipment
connected to the ZigBee network at this time. Two red LEDs on the coordinator are
then lit (see Figure 5-6).
Start the ZeD monitor and then click on the OK button. Before running the ZeD GUI,
the ZigBee coordinator must be connected to the PC through a USB cable.

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


56

Freescale Semiconductor, Inc.

Chapter 5 Application Set-Up

At this moment, there are icons for all of the devices connected to the ZigBee
networkthe power meter plus the coordinator, in this case (see Figure 5-7). If there
is no icon for the power meter, you must reset the power meter by disconnecting
from the line and reset the ZeD GUI using the F5 key. You may also repeat the
installation from point 2 in this case.
In the ZeD GUI menu, you may open a new window for showing the ZigBee data
transfer. This is in Tools/Start SE Utility Control Panel menu. You must address the
meter by clicking the Add New Household ESP Connection, and then click on the
Connect icon (see Figure 5-8).
To show data (only import active energy at this time), click on the Metering icona
kWh data table is now refreshed every 5 seconds. The Meter Report column displays
active energy from the power meter (see Figure 5-9). These numbers are in HEX
format with a widely variable resolution that may be changed by the FreeMASTER
GUI (ZigBee kWh divider dialogue box). Therefore, the kWh-number on the LCD of
the power meter may have a different resolution in comparison to the number in the
ZeD GUI metering data report.
NOTE
Impulse number setting command in the FreeMASTER
GUI (see FreeMASTER data visualization ) should be used
after modification of ZigBee kWh divider number.

Figure 5-7. ZeD GUI

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


Freescale Semiconductor, Inc.

57

Setting up the software demo

Figure 5-8. Add New Household ESP Connection dialog box

Figure 5-9. Metering report in ZeD GUI

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


58

Freescale Semiconductor, Inc.

Appendix A
Schematics

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


Freescale Semiconductor, Inc.

59

Schematic for full configuration of the metering board

A.1 Schematic for full configuration of the metering board

LINE_IN

R14
100
R18
100

BAV99LT1

L_DP
V_BIAS

29
30
TP5

22

GND

VREF_OUT

V_BIAS

TP18

R4
R6
R11
R22
R24

VREGIN

21

TP19

VOUT33

19
20

USB0_DP
USB0_DM

C19
VDDA

GND

0.1UF

42
40
41

VDDMCU

3 PAD JUMPER

GNDA

SJ1
1-2
2-3
4K7
2K2
1K
2K2
100K 220K
4K7
4K7
1K
4K7

C20

VBAT
XTAL32
EXTAL32

Y1
1
2
C21
32.768KHz
18PF
18PF

18

VSS1

GNDA

VDDMAG

2
VDD

1
4

C30
0.1UF

110
109
108

CAP_A
CAP_R

0.1UF

7
6

SCL
SDA

NC

C31

I2C1_SCL
I2C1_SDA

INT1

C28

VLL1
VLL2
VLL3

C32

GND

112
111

C33

ADC1_SE4a/PTE0/SPI1_PCS1/UART1_TX/SDHC0_D1/FB_AD27/I2C1_SDA
ADC1_SE5a/PTE1/SPI1_SOUT/UART1_RX/SDHC0_D0/FB_AD26/I2C1_SCL
ADC1_SE6a/PTE2/SPI1_SCK/UART1_CTS/SDHC0_DCLK/FB_AD25
ADC1_SE7a/PTE3/SPI1_SIN/UART1_RTS/SDHC0_CMD/FB_AD24
PTE4/SPI1_PCS0/UART3_TX/SDHC0_D3/FB_CS3/FB_BE7_0_BLS31_24/FB_TA
PTE5/SPI1_PCS2/UART3_RX/SDHC0_D2/FB_TBST/FB_CS2/FB_BE15_8_BLS23_16
PTE6/SPI1_PCS3/UART3_CTS/I2S0_MCLK/FB_ALE/FB_CS1/FB_TS/I2S0_CLKIN
PTE7/UART3_RTS/I2S0_RXD/FB_CS0
PTE8/UART5_TX/I2S0_RX_FS/FB_AD4
PTE9/UART5_RX/I2S0_RX_BCLK/FB_AD3
PTE10/UART5_CTS/I2S0_TXD/FB_AD2
PTE11/UART5_RTS/I2S0_TX_FS/FB_AD1
PTE12/I2S0_TX_BCLK/FB_AD0

VCAP1
VCAP2

0.1UF

INT1

6
17
44
57
71
93
107
136

TP7
MAG3110

10

GND1

GND

GND

PTD10/UART5_RTS/FB_AD9
PTD11/SPI2_PCS0/UART5_CTS/SDHC0_CLKIN/FB_AD8
PTD12/SPI2_SCK/SDHC0_D4/FB_AD7
PTD13/SPI2_SOUT/SDHC0_D5/FB_AD6
PTD14/SPI2_SIN/SDHC0_D6/FB_AD5
PTD15/SPI2_PCS1/SDHC0_D7/FB_RW

0.1UF 0.1UF 0.1UF

VDDIO

C29
0.1UF

U3

GND2

GND

C27

C26
0.1UF

LCD_P40/PTD0/SPI0_PCS0/UART2_RTS
LCD_P41/ADC0_SE5b/PTD1/SPI0_SCK/UART2_CTS
LCD_P42/PTD2/SPI0_SOUT/UART2_RX
LCD_P43/PTD3/SPI0_SIN/UART2_TX
LCD_P44/PTD4/SPI0_PCS1/UART0_RTS/FTM0_CH4/EWM_IN
LCD_P45/ADC0_SE6b/PTD5/SPI0_PCS2/UART0_CTS/FTM0_CH5/EWM_OUT
LCD_P46/ADC0_SE7b/PTD6/SPI0_PCS3/UART0_RX/FTM0_CH6/FTM0_FLT0
LCD_P47/PTD7/CMT_IRO/UART0_TX/FTM0_CH7/FTM0_FLT1

GND

3-axis IIC Magnetometer

C24
1UF

LCD_P20/ADC0_SE14/TSI0_CH13/PTC0/SPI0_PCS4/PDB0_EXTRG/I2S0_TXD
LCD_P21/ADC0_SE15/TSI0_CH14/PTC1/SPI0_PCS3/UART1_RTS/FTM0_CH0
LCD_P22/ADC0_SE4b/CMP1_IN0/TSI0_CH15/PTC2/SPI0_PCS2/UART1_CTS/FTM0_CH1
LCD_P23/CMP1_IN1/PTC3/SPI0_PCS1/UART1_RX/FTM0_CH2
LCD_P24/PTC4/SPI0_PCS0/UART1_TX/FTM0_CH3/CMP1_OUT
LCD_P25/PTC5/SPI0_SCK/LPT0_ALT2/CMP0_OUT
LCD_P26/CMP0_IN0/PTC6/SPI0_SOUT/PDB0_EXTRG
LCD_P27/CMP0_IN1/PTC7/SPI0_SIN
LCD_P28/ADC1_SE4b/CMP0_IN2/PTC8/I2S0_MCLK/I2S0_CLKIN
LCD_P29/ADC1_SE5b/CMP0_IN3/PTC9/I2S0_RX_BCLK/FTM2_FLT0
LCD_P30/ADC1_SE6b/CMP0_IN4/PTC10/I2C1_SCL/I2S0_RX_FS
LCD_P31/ADC1_SE7b/PTC11/I2C1_SDA/I2S0_RXD
LCD_P32/PTC12/UART4_RTS
LCD_P33/PTC13/UART4_CTS
LCD_P34/PTC14/UART4_RX
LCD_P35/PTC15/UART4_TX
LCD_P36/PTC16/CAN1_RX/UART3_RX
LCD_P37/PTC17/CAN1_TX/UART3_TX
LCD_P38/PTC18/UART3_RTS
LCD_P39/PTC19/UART3_CTS

RESET

C16

SJ1

DAC1_OUT

74

/RESET

R20
4.7K

0.1UF

V_BIAS

DAC0_OUT

39
TP6

Bias selection

GNDA R22
CMP2_IN1 0.6V
4.7K
C18
R24
1K
0.1UF

LCD_P12/TSI0_CH9/PTB16/SPI1_SOUT/UART0_RX/EWM_IN
LCD_P13/TSI0_CH10/PTB17/SPI1_SIN/UART0_TX/EWM_OUT
LCD_P14/TSI0_CH11/PTB18/CAN0_TX/FTM2_CH0/I2S0_TX_BCLK/FTM2_QD_PHA
LCD_P15/TSI0_CH12/PTB19/CAN0_RX/FTM2_CH1/I2S0_TX_FS/FTM2_QD_PHB
LCD_P16/PTB20/SPI2_PCS0/CMP0_OUT
LCD_P17/PTB21/SPI2_SCK/CMP1_OUT
LCD_P18/PTB22/SPI2_SOUT/CMP2_OUT
LCD_P19/PTB23/SPI2_SIN/SPI0_PCS5

PGA1_DP/ADC1_DP0/ADC0_DP3
PGA1_DM/ADC1_DM0/ADC0_DM3

38

TP4
VDDAMCU

V_OUT

100PF

PGA0_DP/ADC0_DP0/ADC1_DP3
PGA0_DM/ADC0_DM0/ADC1_DM3

220PF

L_DM

VDDMCU

C17

ADC1_SE16

27
28

C14

Zero-cross detect
R21
10K

ADC1_DP1
ADC1_DM1

35

D5 25mV+20.4mV
75mV+20.4mV
R15
4.7K
R17
4.7K
25mV-20.4mV
D8 75mV-20.4mV

LCD_P0/ADC0_SE8/ADC1_SE8/TSI0_CH0/PTB0/I2C0_SCL/FTM1_CH0/FTM1_QD_PHA
LCD_P1/ADC0_SE9/ADC1_SE9/TSI0_CH6/PTB1/I2C0_SDA/FTM1_CH1/FTM1_QD_PHB
LCD_P2/ADC0_SE12/TSI0_CH7/PTB2/I2C0_SCL/UART0_RTS/FTM0_FLT3
LCD_P3/ADC0_SE13/TSI0_CH8/PTB3/I2C0_SDA/UART0_CTS/FTM0_FLT0
LCD_P4/ADC1_SE10/PTB4/FTM1_FLT0
LCD_P5/ADC1_SE11/PTB5/FTM2_FLT0
LCD_P6/ADC1_SE12/PTB6
LCD_P7/ADC1_SE13/PTB7
LCD_P8/PTB8/UART3_RTS
LCD_P9/PTB9/SPI1_PCS1/UART3_CTS
LCD_P10/ADC1_SE14/PTB10/SPI1_PCS0/UART3_RX/FTM0_FLT1
LCD_P11/ADC1_SE15/PTB11/SPI1_SCK/UART3_TX/FTM0_FLT2

ADC0_SE16

25
26

TP3

GNDA

CMP2_IN0

36

GNDA

VSS2
VSS3
VSS4
VSS5
VSS6
VSS7
VSS8
VSS9

GND

ADC0_SE17/PTE24/CAN1_TX/UART4_TX/EWM_OUT
ADC0_SE18/PTE25/CAN1_RX/UART4_RX/FB_AD23/EWM_IN
PTE26/UART4_CTS/FB_AD22/RTC_CLKOUT/USB_CLKIN
PTE27/UART4_RTS/FB_AD21
PTE28/FB_AD20

GND

1uH

C37
VDD

B
A

GNDA

2
1

C39

0.1UF 10UF 100PF

BT1

GND

BATTERY

1
3V

D12

CON_2_TB

External
isolated
+3.7V,200mA GND GND
SMPS

C40
47UF

GND

GND
TP13

VDD

C41
0.1UF

GND

TP15
GNDA

BAT54CLT1

C42
100PF

TP10

TP17

3.3V VDDMCU
3

VDDAMCU

GND

VDDA

D11

3V

3.6V
MMSZ5231BT1G

J4

C38

DS1

SJ2 2 PAD JUMPER

VDDA

L1

1
C43

C44

L2

L3
1
MMSZ5231BT1G

R31
47K

D13

0.1UF 10UF

R30
10K

1uH

1uH

3.3V
C45

C46

0.1UF

100PF

GNDA
TP12

VDDMCU

GND

+ C47
47UF

TP11

VDDAMCU

LCD0
LCD1
LCD2
LCD3
LCD33
LCD5
LCD10
LCD17
LCD14
LCD11
LCD8
LCD6
LCD16
LCD15
LCD13
LCD12
LCD9
LCD7

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18

TP14

TP16

VCC_PRESENT

LCD9
LCD8
LCD7
LCD6
LCD5
LCD4
LCD34
LCD33

103
104
105
106
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128

LCD32
LCD31
LCD30
LCD29
LCD28
LCD27
LCD26
LCD25
LCD24
LCD23
LCD22
LCD21
LCD20
LCD19
LCD18

45
46
47
48
49

GNDA

Display

COM1
COM2
COM3
COM4
1G/T5/1E/1F
1B/1D/1C/1A
10G/P5/10E/10F
10B/10D/10C/10A
11G/T6/11E/11F
11B/11D/11C/11A
12G/P7-P6/12E/12F
12B/12D/12C/12A
13G/13E/13F
13B/13D/13C/13A
14G/P8/14E/14F
14B/14D/14C/14A
17
18

19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35

LCD18
LCD19
LCD20
LCD21
LCD22
LCD23
LCD24
LCD25
LCD26
LCD27
LCD28
LCD29
LCD30
LCD31
LCD32
LCD34
LCD4

WP
VSS

GND

HOLD
EXP

ISO1

R12

(+12V)

390
VDD
1

4
SFH6106-4

R16
1.0K

C15
2.2UF

ISO2

D6

1 1

J8
1

SFH6106-4

2
4
6
8
10

RXD 3
TXD 5
DTR 7
GND 9

CON_2X5

D9

MMSD4148T1G

RS232 isolated
(Half Duplex,
max 19200 Bd)

GND
ISO3
2

EOC_OC 2
EOC_OE 1

R23

390

CON_2_TB
B
A
J6

Energy output
pulse interface

4
SFH6106-4

C22

SPI

SW1

VDD

VCC_PRESENT

5
3
1

INT1
SPI2_CS0
SPI2_SCK
SPI2_SOUT
SPI2_SIN

0.1UF

J9

SW1

GND

6
4
2

HDR 2X3

SW1

C23 3

GND

0.1UF
LIGHT TOUCH PUSH BUTTON

VDD

I2C

R25

R26

4.7K

4.7K VDD

C25
5
3
1

I2C1_SCL
I2C1_SDA
TAMPER1
VDDMAG
TAMPER2

IR_TX
IR_RX
EOC

D7

RS232
Interface

R19
470

VDD

RS232_TXD
RS232_RXD
LED_kVarh
LED_kWh
LED_USR

RTS

R13
4.7K

0.1UF

J7

6
4
2

GND

HDR 2X3

Tamper Detection
C35

0.1UF

C34
0.1UF
SW2

J5
A
1

CON_2_TB

GND

3
2

GND

D2F-01L

IR_TX
IR_RX

TP8
VDD

C36
T7/T8/P4/H
2G/T3/2E/2F
2B/2D/2C/2A
3G/T2/3E/3F
3B/3D/3C/3A
4G/T1/4E/4F
4B/4D/4C/4A
5G/T4/5E/5F
5B/5D/5C/5A
6G/P1/6E/6F
6B/6D/6C/6A
7G/P2/7E/7F
7B/7D/7C/7A
8G/COL1-COL2/8E/8F
8B/8D/8C/8A
9G/P3/9E/9F
9B/9D/9C/9A

0.1UF

MRAM

CS

TP9

MK40X256VLQ100

Power section

95
96
97
98
99
100
101
102

1
2
3
4
7
8
9
10
11
12
13
14
15

MRAM_CTRL
SPI0_SIN

C13

SO

SCK

GND

LCD0
LCD1
LCD2
LCD3
LCD17
LCD16
LCD15
LCD14
LCD13
LCD12
LCD11
LCD10

139
140
141
142
143
144

VDD
SI

MR25H10CDC

81
82
83
84
85
86
87
88
89
90
91
92

129
130
131
132
133
134
135
138

LINE_OUT

ADC0_DP1
ADC0_DM1

75
76
77
78
79
80

U2
5

SPI0_SOUT
SPI0_SCK
SPI0_CS0

MMSD4148T1G

V_OUT

PTA24/FB_AD14
PTA25/FB_AD13
PTA26/FB_AD12
PTA27/FB_AD11
PTA28/FB_AD10
PTA29/FB_AD19

VREF_OUT

23
24

0.1UF

LPF CUTOFF
3.4MHz

VSSA

37

1.2V

Optical Interface

BAV99LT1
2

B
J3
Shunt

GNDA

VREF_OUT
C10

Port C

2
A

C9
1000pF

R6
1K

GNDA

CON_2_TB

34

VDDAMCU
GNDA

VREFL

0.6V+/-0.5V

D4

VDDAMCU

Current
measurement
5(120)A

33

Port D

2
GND

R10
47

R9
100K
R11
100K
R5
220K
R7
220K

RS1
20S0271

CON_2_TB

4.7K

BAV99LT1
1

VREFH

Port E

VDDA

32

C8
GNDA
0.1UF

Port A

C7
0.1UF
TP2

R4

J2

VDD

GND

HDR_19P
VDDMRAM
CMP2_IN0
CMP2_IN1

31

LED_USR

VDDAMCU
V_BIAS

LED_kWh

9
11
13
15
17
19

MMSD4148T1G

GND

Voltage measurement

50
51
52
53
54
55
58
59
60
61
62
63
64
65
66
67
68
69
72
73

R28
22K
R29
1.0K

D10

OP506B

0.1UF
GND

R27
680.0

Q1

0.1UF 0.1UF 0.1UF 0.1UF 0.1UF 0.1UF 0.1UF

JTAG_TCLK/SWD_CLK/EZP_CLK/TSI0_CH1/PTA0/UART0_CTS/FTM0_CH5
JTAG_TDI/EZP_DI/TSI0_CH2/PTA1/UART0_RX/FTM0_CH6
JTAG_TDO/TRACE_SWO/EZP_DO/TSI0_CH3/PTA2/UART0_TX/FTM0_CH7
JTAG_TMS/SWD_DIO/TSI0_CH4/PTA3/UART0_RTS/FTM0_CH0
NMI/EZP_CS/TSI0_CH5/PTA4/FTM0_CH1
JTAG_TRST/PTA5/FTM0_CH2/CMP2_OUT/I2S0_RX_BCLK
PTA6/FTM0_CH3/FB_CLKOUT/TRACE_CLKOUT
ADC0_SE10/PTA7/FTM0_CH4/FB_AD18/TRACE_D3
ADC0_SE11/PTA8/FTM1_CH0/FB_AD17/FTM1_QD_PHA/TRACE_D2
PTA9/FTM1_CH1/FB_AD16/FTM1_QD_PHB/TRACE_D1
PTA10/FTM2_CH0/FB_AD15/FTM2_QD_PHA/TRACE_D0
PTA11/FTM2_CH1/FB_OE/FTM2_QD_PHB
CMP2_IN0/PTA12/CAN0_TX/FTM1_CH0/FB_CS5/FB_TSIZ1/FB_BE23_16_BLS15_8/I2S0_TXD/FTM1_QD_PHA
CMP2_IN1/PTA13/CAN0_RX/FTM1_CH1/FB_CS4/FB_TSIZ0/FB_BE31_24_BLS7_0/I2S0_TX_FS/FTM1_QD_PHB
PTA14/SPI0_PCS0/UART0_TX/FB_AD31/I2S0_TX_BCLK
PTA15/SPI0_SCK/UART0_RX/FB_AD30/I2S0_RXD
PTA16/SPI0_SOUT/UART0_CTS/FB_AD29/I2S0_RX_FS
ADC1_SE17/PTA17/SPI0_SIN/UART0_RTS/FB_AD28/I2S0_MCLK/I2S0_CLKIN
EXTAL/PTA18/FTM0_FLT2/FTM_CLKIN0
XTAL/PTA19/FTM1_FLT0/FTM_CLKIN1/LPT0_ALT1

VDD1
VDD2
VDD3
VDD4
VDD5
VDD6
VDD7

TSAL4400

5
16
43
56
70
94
137

C6

0.1UF

GND

Infrared interface

C5

D1
C
A
R2
390
WP7104LSRD
D2
C
A
R3
390
WP7104LSRD
D3
C
A
R8
390
LED RED

LED_kVarh
C1
1
3
5

C4

VDDMCU
J1

2
4
6
8
/RESET 10
12
14
16
18
20

C3

VDDMCU
R1
10K

RS232_TXD
RS232_RXD

C12

JTAG

EOC

C2

Port B

C11

R32
47K
TP1

U1

VDDMCU

VDDMCU

GND

150020254

Figure A-1. Schematic for full configuration of the metering board

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


60

Freescale Semiconductor, Inc.

A.2 Schematic for low-cost configuration of the metering


board
R32
47K

VDDMCU

C11

C2

C12

C3

C4

C5

5
16
43
56
70
94
137

C6

0.1UF 0.1UF 0.1UF 0.1UF 0.1UF 0.1UF 0.1UF


GND

31
C7
0.1UF
TP2

BAV99LT1
2

GNDA

1
2

LINE_OUT

R14
100
R18
100

LINE_IN

V_OUT

GNDA

D5 25mV+20.4mV
75mV+20.4mV
R15
4.7K
R17
4.7K
25mV-20.4mV
D8 75mV-20.4mV

L_DP

L_DM
TP5

DAC1_OUT

74

/RESET

R20
4.7K

VREF_OUT

V_BIAS

22
TP18

VREGIN

21

TP19

VOUT33

19
20

USB0_DP
USB0_DM

C19
VDDA

GND

0.1UF

42
40
41

VDDMCU

3 PAD JUMPER

Y1

SJ1
1-2
2-3
R4 4K7
2K2
R6 1K
2K2
R11 100K 220K
R22 4K7
4K7
R24 1K
4K7

C20

LCD_P20/ADC0_SE14/TSI0_CH13/PTC0/SPI0_PCS4/PDB0_EXTRG/I2S0_TXD
LCD_P21/ADC0_SE15/TSI0_CH14/PTC1/SPI0_PCS3/UART1_RTS/FTM0_CH0
LCD_P22/ADC0_SE4b/CMP1_IN0/TSI0_CH15/PTC2/SPI0_PCS2/UART1_CTS/FTM0_CH1
LCD_P23/CMP1_IN1/PTC3/SPI0_PCS1/UART1_RX/FTM0_CH2
LCD_P24/PTC4/SPI0_PCS0/UART1_TX/FTM0_CH3/CMP1_OUT
LCD_P25/PTC5/SPI0_SCK/LPT0_ALT2/CMP0_OUT
LCD_P26/CMP0_IN0/PTC6/SPI0_SOUT/PDB0_EXTRG
LCD_P27/CMP0_IN1/PTC7/SPI0_SIN
LCD_P28/ADC1_SE4b/CMP0_IN2/PTC8/I2S0_MCLK/I2S0_CLKIN
LCD_P29/ADC1_SE5b/CMP0_IN3/PTC9/I2S0_RX_BCLK/FTM2_FLT0
LCD_P30/ADC1_SE6b/CMP0_IN4/PTC10/I2C1_SCL/I2S0_RX_FS
LCD_P31/ADC1_SE7b/PTC11/I2C1_SDA/I2S0_RXD
LCD_P32/PTC12/UART4_RTS
LCD_P33/PTC13/UART4_CTS
LCD_P34/PTC14/UART4_RX
LCD_P35/PTC15/UART4_TX
LCD_P36/PTC16/CAN1_RX/UART3_RX
LCD_P37/PTC17/CAN1_TX/UART3_TX
LCD_P38/PTC18/UART3_RTS
LCD_P39/PTC19/UART3_CTS

RESET

C16

GND

GNDA

DAC0_OUT

TP6

0.1UF

V_BIAS

LCD_P12/TSI0_CH9/PTB16/SPI1_SOUT/UART0_RX/EWM_IN
LCD_P13/TSI0_CH10/PTB17/SPI1_SIN/UART0_TX/EWM_OUT
LCD_P14/TSI0_CH11/PTB18/CAN0_TX/FTM2_CH0/I2S0_TX_BCLK/FTM2_QD_PHA
LCD_P15/TSI0_CH12/PTB19/CAN0_RX/FTM2_CH1/I2S0_TX_FS/FTM2_QD_PHB
LCD_P16/PTB20/SPI2_PCS0/CMP0_OUT
LCD_P17/PTB21/SPI2_SCK/CMP1_OUT
LCD_P18/PTB22/SPI2_SOUT/CMP2_OUT
LCD_P19/PTB23/SPI2_SIN/SPI0_PCS5

PGA1_DP/ADC1_DP0/ADC0_DP3
PGA1_DM/ADC1_DM0/ADC0_DM3

39

VDDAMCU

SJ1

GNDA R22
CMP2_IN1 0.6V
4.7K
C18
R24
1K
0.1UF

PGA0_DP/ADC0_DP0/ADC1_DP3
PGA0_DM/ADC0_DM0/ADC1_DM3

38

TP4

Bias selection

100PF

ADC1_SE16

220PF
29
30

V_OUT

R21
10K

ADC1_DP1
ADC1_DM1

27
28

C14
V_BIAS

LCD_P0/ADC0_SE8/ADC1_SE8/TSI0_CH0/PTB0/I2C0_SCL/FTM1_CH0/FTM1_QD_PHA
LCD_P1/ADC0_SE9/ADC1_SE9/TSI0_CH6/PTB1/I2C0_SDA/FTM1_CH1/FTM1_QD_PHB
LCD_P2/ADC0_SE12/TSI0_CH7/PTB2/I2C0_SCL/UART0_RTS/FTM0_FLT3
LCD_P3/ADC0_SE13/TSI0_CH8/PTB3/I2C0_SDA/UART0_CTS/FTM0_FLT0
LCD_P4/ADC1_SE10/PTB4/FTM1_FLT0
LCD_P5/ADC1_SE11/PTB5/FTM2_FLT0
LCD_P6/ADC1_SE12/PTB6
LCD_P7/ADC1_SE13/PTB7
LCD_P8/PTB8/UART3_RTS
LCD_P9/PTB9/SPI1_PCS1/UART3_CTS
LCD_P10/ADC1_SE14/PTB10/SPI1_PCS0/UART3_RX/FTM0_FLT1
LCD_P11/ADC1_SE15/PTB11/SPI1_SCK/UART3_TX/FTM0_FLT2

ADC0_SE16

35

Zero-cross detect
C17

36

GNDA

25
26

VDDMCU

CMP2_IN0

ADC0_DP1
ADC0_DM1

VBAT
XTAL32
EXTAL32

C21

32.768KHz
18PF
18PF

18

VSS1

GNDA

COM1
COM2
COM3
COM4
1G/T5/1E/1F
1B/1D/1C/1A
10G/P5/10E/10F
10B/10D/10C/10A
11G/T6/11E/11F
11B/11D/11C/11A
12G/P7-P6/12E/12F
12B/12D/12C/12A
13G/13E/13F
13B/13D/13C/13A
14G/P8/14E/14F
14B/14D/14C/14A
17
18

T7/T8/P4/H
2G/T3/2E/2F
2B/2D/2C/2A
3G/T2/3E/3F
3B/3D/3C/3A
4G/T1/4E/4F
4B/4D/4C/4A
5G/T4/5E/5F
5B/5D/5C/5A
6G/P1/6E/6F
6B/6D/6C/6A
7G/P2/7E/7F
7B/7D/7C/7A
8G/COL1-COL2/8E/8F
8B/8D/8C/8A
9G/P3/9E/9F
9B/9D/9C/9A

19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35

110
109
108

LCD18
LCD19
LCD20
LCD21
LCD22
LCD23
LCD24
LCD25
LCD26
LCD27
LCD28
LCD29
LCD30
LCD31
LCD32
LCD34
LCD4

C31

C28

VLL1
VLL2
VLL3

C32

GND

112
111

C33

VCAP1
VCAP2

0.1UF
6
17
44
57
71
93
107
136

VSS2
VSS3
VSS4
VSS5
VSS6
VSS7
VSS8
VSS9

150020254

Display

GND

LCD9
LCD8
LCD7
LCD6
LCD5
LCD4
LCD34
LCD33

103
104
105
106
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128

LCD32
LCD31
LCD30
LCD29
LCD28
LCD27
LCD26
LCD25
LCD24
LCD23
LCD22
LCD21
LCD20
LCD19
LCD18

D1
C
A
R2
390
WP7104LSRD
D2
C
A
R3
390
WP7104LSRD
D3

LED_kVarh

LED_kWh

VDD

Optical Interface
SW1

VCC_PRESENT

SW1

C23 3

GND

0.1UF
LIGHT TOUCH PUSH BUTTON

TAMPER1
TAMPER2
C35
0.1UF

C34
0.1UF
SW2

J5
A

2
RS232_TXD
B
RS232_RXD
LED_kVarh
CON_2_TB
LED_kWh
GND
LED_USR

3
2

GND

D2F-01L

Tamper Detection

BT1

BATTERY

1
3V

MMSZ5231BT1G

CON_2_TB

External
isolated
+3.7V,200mA GND GND
SMPS

C40
47UF

GND

GND
TP13

VDD

C41
0.1UF

GND
TP10

VDDA

1
C43

C44

L3
1
MMSZ5231BT1G

R30
10K

GNDA

R31
47K

1uH

D13

0.1UF 10UF

TP15

TP17
GND

BAT54CLT1

C42
100PF

VDDAMCU
L2

1uH

C45

C46

0.1UF

100PF

GND

SFH6106-4
R16
1.0K

+ C47
47UF

TP11

VDDAMCU

TP14

TP16

VCC_PRESENT

3.3V

GNDA
TP12

VDDMCU

R13
4.7K

VDD

3.3V VDDMCU
3

3.6V
D12

D11

3V

C15
2.2UF

ISO2

D6

1 1

2
GND

RTS

SFH6106-4

GNDA

RS232
Interface
J8

D7

R19
470
D9

MMSD4148T1G

C39

(+12V)

2
1

C38

0.1UF 10UF 100PF


GNDA

390

C37
VDD

R12

ISO1
2

MMSD4148T1G

VDDA

RS232_TXD
RS232_RXD

1uH

L1

SJ2 2 PAD JUMPER

95
96
97
98
99
100
101
102

45
46
47
48
49

ADC0_SE17/PTE24/CAN1_TX/UART4_TX/EWM_OUT
ADC0_SE18/PTE25/CAN1_RX/UART4_RX/FB_AD23/EWM_IN
PTE26/UART4_CTS/FB_AD22/RTC_CLKOUT/USB_CLKIN
PTE27/UART4_RTS/FB_AD21
PTE28/FB_AD20
MK40X256VLQ100

9
11
13
15
17
19

GND

Power section

J4

LCD0
LCD1
LCD2
LCD3
LCD17
LCD16
LCD15
LCD14
LCD13
LCD12
LCD11
LCD10

1
2
3
4
7
8
9
10
11
12
13
14
15

ADC1_SE4a/PTE0/SPI1_PCS1/UART1_TX/SDHC0_D1/FB_AD27/I2C1_SDA
ADC1_SE5a/PTE1/SPI1_SOUT/UART1_RX/SDHC0_D0/FB_AD26/I2C1_SCL
ADC1_SE6a/PTE2/SPI1_SCK/UART1_CTS/SDHC0_DCLK/FB_AD25
ADC1_SE7a/PTE3/SPI1_SIN/UART1_RTS/SDHC0_CMD/FB_AD24
PTE4/SPI1_PCS0/UART3_TX/SDHC0_D3/FB_CS3/FB_BE7_0_BLS31_24/FB_TA
PTE5/SPI1_PCS2/UART3_RX/SDHC0_D2/FB_TBST/FB_CS2/FB_BE15_8_BLS23_16
PTE6/SPI1_PCS3/UART3_CTS/I2S0_MCLK/FB_ALE/FB_CS1/FB_TS/I2S0_CLKIN
PTE7/UART3_RTS/I2S0_RXD/FB_CS0
PTE8/UART5_TX/I2S0_RX_FS/FB_AD4
PTE9/UART5_RX/I2S0_RX_BCLK/FB_AD3
PTE10/UART5_CTS/I2S0_TXD/FB_AD2
PTE11/UART5_RTS/I2S0_TX_FS/FB_AD1
PTE12/I2S0_TX_BCLK/FB_AD0

0.1UF 0.1UF 0.1UF

Port E

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18

LCD0
LCD1
LCD2
LCD3
LCD33
LCD5
LCD10
LCD17
LCD14
LCD11
LCD8
LCD6
LCD16
LCD15
LCD13
LCD12
LCD9
LCD7

0.1UF

HDR_19P

139
140
141
142
143
144

PTD10/UART5_RTS/FB_AD9
PTD11/SPI2_PCS0/UART5_CTS/SDHC0_CLKIN/FB_AD8
PTD12/SPI2_SCK/SDHC0_D4/FB_AD7
PTD13/SPI2_SOUT/SDHC0_D5/FB_AD6
PTD14/SPI2_SIN/SDHC0_D6/FB_AD5
PTD15/SPI2_PCS1/SDHC0_D7/FB_RW

DS1

C1
1
3
5

CMP2_IN0
CMP2_IN1

81
82
83
84
85
86
87
88
89
90
91
92

129
130
131
132
133
134
135
138

LCD_P40/PTD0/SPI0_PCS0/UART2_RTS
LCD_P41/ADC0_SE5b/PTD1/SPI0_SCK/UART2_CTS
LCD_P42/PTD2/SPI0_SOUT/UART2_RX
LCD_P43/PTD3/SPI0_SIN/UART2_TX
LCD_P44/PTD4/SPI0_PCS1/UART0_RTS/FTM0_CH4/EWM_IN
LCD_P45/ADC0_SE6b/PTD5/SPI0_PCS2/UART0_CTS/FTM0_CH5/EWM_OUT
LCD_P46/ADC0_SE7b/PTD6/SPI0_PCS3/UART0_RX/FTM0_CH6/FTM0_FLT0
LCD_P47/PTD7/CMT_IRO/UART0_TX/FTM0_CH7/FTM0_FLT1

GND

VDDMCU
J1

2
4
6
8
/RESET 10
12
14
16
18
20

75
76
77
78
79
80

PTA24/FB_AD14
PTA25/FB_AD13
PTA26/FB_AD12
PTA27/FB_AD11
PTA28/FB_AD10
PTA29/FB_AD19

VREF_OUT

23
24

TP3

BAV99LT1

J3
Shunt

VSSA

37

1.2V

0.1UF

LPF CUTOFF
3.4MHz

GNDA

GNDA

VREF_OUT
C10

VDDAMCU

CON_2_TB

C9
1000pF

R6
1K

VDDAMCU

Current
measurement
5(120)A

VREFL

34

D4

GND

VREFH

33

0.6V+/-0.5V

Port C

RS1
20S0271

R10
47

32

C8
GNDA
0.1UF

R9
100K
R11
100K
R5
220K
R7
220K

BAV99LT1
1

B
CON_2_TB

4.7K

Port D

R4
1

VDDA

Port A

V_BIAS

VDDMCU
R1
10K

50
51
52
53
54
55
58
59
60
61
62
63
64
65
66
67
68
69
72
73

JTAG_TCLK/SWD_CLK/EZP_CLK/TSI0_CH1/PTA0/UART0_CTS/FTM0_CH5
JTAG_TDI/EZP_DI/TSI0_CH2/PTA1/UART0_RX/FTM0_CH6
JTAG_TDO/TRACE_SWO/EZP_DO/TSI0_CH3/PTA2/UART0_TX/FTM0_CH7
JTAG_TMS/SWD_DIO/TSI0_CH4/PTA3/UART0_RTS/FTM0_CH0
NMI/EZP_CS/TSI0_CH5/PTA4/FTM0_CH1
JTAG_TRST/PTA5/FTM0_CH2/CMP2_OUT/I2S0_RX_BCLK
PTA6/FTM0_CH3/FB_CLKOUT/TRACE_CLKOUT
ADC0_SE10/PTA7/FTM0_CH4/FB_AD18/TRACE_D3
ADC0_SE11/PTA8/FTM1_CH0/FB_AD17/FTM1_QD_PHA/TRACE_D2
PTA9/FTM1_CH1/FB_AD16/FTM1_QD_PHB/TRACE_D1
PTA10/FTM2_CH0/FB_AD15/FTM2_QD_PHA/TRACE_D0
PTA11/FTM2_CH1/FB_OE/FTM2_QD_PHB
CMP2_IN0/PTA12/CAN0_TX/FTM1_CH0/FB_CS5/FB_TSIZ1/FB_BE23_16_BLS15_8/I2S0_TXD/FTM1_QD_PHA
CMP2_IN1/PTA13/CAN0_RX/FTM1_CH1/FB_CS4/FB_TSIZ0/FB_BE31_24_BLS7_0/I2S0_TX_FS/FTM1_QD_PHB
PTA14/SPI0_PCS0/UART0_TX/FB_AD31/I2S0_TX_BCLK
PTA15/SPI0_SCK/UART0_RX/FB_AD30/I2S0_RXD
PTA16/SPI0_SOUT/UART0_CTS/FB_AD29/I2S0_RX_FS
ADC1_SE17/PTA17/SPI0_SIN/UART0_RTS/FB_AD28/I2S0_MCLK/I2S0_CLKIN
EXTAL/PTA18/FTM0_FLT2/FTM_CLKIN0
XTAL/PTA19/FTM1_FLT0/FTM_CLKIN1/LPT0_ALT1

VDD1
VDD2
VDD3
VDD4
VDD5
VDD6
VDD7

VDDAMCU

Voltage measurement

J2

U1

Port B

VDDMCU

JTAG

TP1

RXD
TXD
DTR
GND

1
3
5
7
9

2
4
6
8
10
CON_2X5

MMSD4148T1G

RS232 isolated
(Half Duplex,
max 19200 Bd)

GND

Figure A-2. Schematic for low-cost configuration of the metering board

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


Freescale Semiconductor, Inc.

61

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


62

Freescale Semiconductor, Inc.

Appendix B
Layouts

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


Freescale Semiconductor, Inc.

63

Layouts for full configuration of the metering board

B.1 Layouts for full configuration of the metering board

Figure B-1. Top side of the board for full configuration

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


64

Freescale Semiconductor, Inc.

Appendix B Layouts

Figure B-2. Bottom side of the board for full configuration

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


Freescale Semiconductor, Inc.

65

Layouts for low-cost configuration of the metering board

B.2 Layouts for low-cost configuration of the metering board

Figure B-3. Top side of the board for low-cost configuration

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


66

Freescale Semiconductor, Inc.

Figure B-4. Bottom side of the board for low-cost configuration

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


Freescale Semiconductor, Inc.

67

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


68

Freescale Semiconductor, Inc.

Appendix C
BOM
C.1 Bill of materials for full configuration of the metering
board
Table C-1. BOM report for full configuration

Part Reference

Quantity

Description

Manufacturer

Part Number

BT1

Battery holder CR2032 3V


ROHS COMPLIANT

Renata Batteries

SMTU2032-LF

C1 C2 C3 C4 C5 C6 C7
C8 C10 C11 C12 C13
C16 C18 C19 C22 C23
C25 C26 C27 C28 C29
C30 C31 C32 C33 C34
C35 C36 C37 C41 C43
C45

33

CAP CER 0.1UF 25V


10% X7R 0805

SMEC

MCCC104K2NRTF

C9

CAP CER 1000PF 50V


10% X7R 0805

AVX

08055C102KAT2A

C14

CAP CER 220PF 100V


5% C0G 0805

AVX

08051A221JAT2A

C15

CAP TANT 2.2UF 16V


10% -- 3216-18

KEMET

T491A225K016AT

C17 C39 C42 C46

CAP CER 100PF 50V


10% C0G 0805

AVX

08055A101KAT2A

C20 C21

CAP CER 18PF 50V 5%


C0G 0805

AVX

08055A180JAT2A

C24

CAP CER 1UF 25V 10%


X5R 0805

KEMET

C0805C105K3RAC7800

C38 C44

CAP CER 10UF 16V 10%


X5R 0805

AVX

0805YD106KAT2A

C40 C47

CAP ALEL 47UF 6.3V


20% -- CASE C SMT

PANASONIC

EEE0JA470SR

D1 D2

LED RED SGL 30mA TH

Kingbright

WP7104LSRD

D3

LED RED SGL 30MA


SMT

Kingbright

KPT-3216ID

Table continues on the next page...

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


Freescale Semiconductor, Inc.

69

Bill of materials for full configuration of the metering board

Table C-1. BOM report for full configuration (continued)


Part Reference

Quantity

Description

Manufacturer

Part Number

D4 D5 D8

DIODE DUAL SW 215MA


70V SOT23

ON SEMICONDUCTOR

BAV99LT1G

D6 D7 D9

DIODE SW 100V
SOD-123

ON SEMICONDUCTOR

MMSD4148T1G

D10

LED IR SGL 100MA TH

VISHAY
INTERTECHNOLOGY

TSAL4400

D11

DIODE SCH DUAL CC


200MA 30V SOT23

ON SEMICONDUCTOR

BAT54CLT1G

D12 D13

DIODE ZNR 5.1V 0.5W


SOD123

ON SEMICONDUCTOR

MMSZ5231BT1G

ISO1 ISO2 ISO3

IC OPTOCOUPLER
100MA 70V SMD

VISHAY
INTERTECHNOLOGY

SFH6106-4

J1

HDR 19P SMT 50MIL SP


251H AU

SAMTEC

ASP-159234-03

J2 J3 J4 J5 J6

CON 1X2 TB TH 5MM SP


394H --

LUMBERG INC

DON'T POPULATE

J7 J9

HDR 2X3 TH 100MIL


CTR 335H AU 95L

SAMTEC

TSW-103-07-S-D

J8

CON 2X5 PLUG SHRD


TH 100MIL CTR 358H AU
118L

ADAM TECHNOLOGIES

BRH-10-VUA

L1 L2 L3

IND CHIP 1UH@10MHZ


220MA 25%

TDK

MLZ2012A1R0PT

DS1

LCD DISPLAY 3.3V TH

MAK-SAY

150020254

Q1

TRAN PHOTO NPN


250mA 30V TH

OPTEK TECHNOLOGY
INC

OP506B

R1 R21 R30

RES MF 10K 1/8W 5%


0805

VENKEL COMPANY

CR0805-8W-103JT

R2 R3 R8 R12 R23

RES MF 390 OHM 1/8W


5% 0805

BOURNS

CR0805-JW-391ELF

R4 R15 R17 R22

RES MF 4.7K 1/4W 1%


MELF0204

WELWYN
COMPONENTS LIMITED

WRM0204C-4K7FI

R5 R7

RES MF 220K 1/4W 1%


50ppm MELF0204

WELWYN
COMPONENTS LIMITED

WRM0204C-220KFI

R6 R24

RES MF 1K 1/4W 1%
MELF0204

WELWYN
COMPONENTS LIMITED

WRM0204C-1K0FI

R9 R11

RES MF 100K 1/4W 1%


MELF0204

WELWYN
COMPONENTS LIMITED

WRM0204C-100KFI

R10

RES MF 47 OHM 1/8W


5% 0805

Rohm

MCR10EZPJ470

R13 R20 R25 R26

RES MF 4.70K 1/8W 1%


0805

BOURNS

CR0805-FX-4701ELF

Table continues on the next page...

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


70

Freescale Semiconductor, Inc.

Appendix C BOM

Table C-1. BOM report for full configuration (continued)


Part Reference

Quantity

Description

Manufacturer

Part Number

R14 R18

RES MF 100 OHM 1/4W


1% 50PPM MELF0204

WELWYN
COMPONENTS LIMITED

WRM0204C-100RFI

R16 R29

RES MF 1.00K 1/8W 1%


0805

KOA SPEER

RK73H2ATTD1001F

R19

RES MF 470.0 1/8W 5%


0805

BOURNS

CR0805-JW-471ELF

R27

RES MF 680 OHM 1/8W


1% 0805

YAGEO AMERICA

RC0805FR-07680RL

R28

RES MF 22K 1/8W 5%


0805

BOURNS

CR0805-JW-223ELF

R31 R32

RES MF 47K 1/8W 5%


0805

SMEC

RC73L2D473JTF

RS1

RES VARISTOR
275VRMS 10% 4.5kA
151J TH

EPCOS

B72220S0271K101

SJ1

JUMPER 3 PAD 40MIL


SQUARE SMT

N/A

NO PART TO ORDER

SJ2

JUMPER 2 PAD 40 MIL


SQUARE SMT

N/A

NO PART TO ORDER

SW1

SW SPST MOM NO PB
20MA 15V TH

PANASONIC

EVQPAC05R

SW2

SW SPDT SNAP ACTION


0.1A 30V TH

OMRON

D2F-01L

TP1 TP2 TP3 TP4 TP5


TP6 TP7 TP8 TP9 TP10
TP11 TP12 TP13 TP14
TP15 TP16 TP17 TP18
TP19

19

TEST POINT TH PAD 60


DRILL 35 DIAM, NO
PART TO ORDER

N/A

NO PART TO ORDER

U1

IC MCU P2 MARCONI
32BIT 96K FLASH 16K
RAM 2.7-5.5V LQFP144

FREESCALE
SEMICONDUCTOR

PK40X256VLQ100

U2

IC MEM MRAM 1Mb SPI


2.7-3.6V DFN8

EVERSPIN
TECHNOLOGIES, INC

MR25H10CDC

U3

IC 3-AXIS DIGITAL
MAGNETOMETER
1.95-3.6V DFN10

FREESCALE
SEMICONDUCTOR

MAG3110

Y1

XTAL 32.768KHZ PAR


20PPM -- SMT

Citizen

CMR200T32.768KDZFUT

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


Freescale Semiconductor, Inc.

71

Bill of materials for low-cost configuration of the metering board

C.2 Bill of materials for low-cost configuration of the


metering board
Table C-2. BOM report for low-cost configuration

Part Reference

Quantity

Description

Manufacturer

Part Number

BT1

Battery holder CR2032 3V


ROHS COMPLIANT

Renata Batteries

SMTU2032-LF

C1 C2 C3 C4 C5 C6 C7
C8 C10 C11 C12 C16
C18 C19 C23 C28 C31
C32 C33 C34 C35 C37
C41 C43 C45

25

CAP CER 0.1UF 25V


10% X7R 0805

SMEC

MCCC104K2NRTF

C9

CAP CER 1000PF 50V


10% X7R 0805

AVX

08055C102KAT2A

C14

CAP CER 220PF 100V


5% C0G 0805

AVX

08051A221JAT2A

C15

CAP TANT 2.2UF 16V


10% -- 3216-18

KEMET

T491A225K016AT

C17 C39 C42 C46

CAP CER 100PF 50V


10% C0G 0805

AVX

08055A101KAT2A

C20 C21

CAP CER 18PF 50V 5%


C0G 0805

AVX

08055A180JAT2A

C38 C44

CAP CER 10UF 16V 10%


X5R 0805

AVX

0805YD106KAT2A

C40 C47

CAP ALEL 47UF 6.3V


20% -- CASE C SMT

PANASONIC

EEE0JA470SR

D1 D2

LED RED SGL 30mA TH

Kingbright

WP7104LSRD

D4 D5 D8

DIODE DUAL SW 215MA


70V SOT23

ON SEMICONDUCTOR

BAV99LT1G

D6 D7 D9

DIODE SW 100V
SOD-123

ON SEMICONDUCTOR

MMSD4148T1G

D11

DIODE SCH DUAL CC


200MA 30V SOT23

ON SEMICONDUCTOR

BAT54CLT1G

D12 D13

DIODE ZNR 5.1V 0.5W


SOD123

ON SEMICONDUCTOR

MMSZ5231BT1G

ISO1 ISO2

IC OPTOCOUPLER
100MA 70V SMD

VISHAY
INTERTECHNOLOGY

SFH6106-4

J1

HDR 19P SMT 50MIL SP


251H AU

SAMTEC

ASP-159234-03

J2 J3 J4 J5

CON 1X2 TB TH 5MM SP


394H --

N/A

DON'T POPULATE

J8

CON 2X5 PLUG SHRD


TH 100MIL CTR 358H AU
118L

ADAM TECHNOLOGIES

BRH-10-VUA

Table continues on the next page...

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


72

Freescale Semiconductor, Inc.

Appendix C BOM

Table C-2. BOM report for low-cost configuration (continued)


Part Reference

Quantity

Description

Manufacturer

Part Number

L1 L2 L3

IND CHIP 1UH@10MHZ


220MA 25%

TDK

MLZ2012A1R0PT

DS1

LCD DISPLAY 3.3V TH

MAK-SAY

150020254

R1 R21 R30

RES MF 10K 1/8W 5%


0805

VENKEL COMPANY

CR0805-8W-103JT

R2 R3 R12

RES MF 390 OHM 1/8W


5% 0805

BOURNS

CR0805-JW-391ELF

R4 R15 R17 R22

RES MF 4.7K 1/4W 1%


MELF0204

WELWYN
COMPONENTS LIMITED

WRM0204C-4K7FI

R5 R7

RES MF 220K 1/4W 1%


50ppm MELF0204

WELWYN
COMPONENTS LIMITED

WRM0204C-220KFI

R6 R24

RES MF 1K 1/4W 1%
MELF0204

WELWYN
COMPONENTS LIMITED

WRM0204C-1K0FI

R9 R11

RES MF 100K 1/4W 1%


MELF0204

WELWYN
COMPONENTS LIMITED

WRM0204C-100KFI

R10

RES MF 47 OHM 1/8W


5% 0805

Rohm

MCR10EZPJ470

R13 R20

RES MF 4.70K 1/8W 1%


0805

BOURNS

CR0805-FX-4701ELF

R14 R18

RES MF 100 OHM 1/4W


1% 50PPM MELF0204

WELWYN
COMPONENTS LIMITED

WRM0204C-100RFI

R16

RES MF 1.00K 1/8W 1%


0805

KOA SPEER

RK73H2ATTD1001F

R19

RES MF 470.0 1/8W 5%


0805

BOURNS

CR0805-JW-471ELF

R31 R32

RES MF 47K 1/8W 5%


0805

SMEC

RC73L2D473JTF

RS1

RES VARISTOR
275VRMS 10% 4.5kA
151J TH

EPCOS

B72220S0271K101

SJ1

JUMPER 3 PAD 40MIL


SQUARE SMT

N/A

NO PART TO ORDER

SJ2

JUMPER 2 PAD 40 MIL


SQUARE SMT

N/A

NO PART TO ORDER

SW1

SW SPST MOM NO PB
20MA 15V TH

PANASONIC

EVQPAC05R

SW2

SW SPDT SNAP ACTION


0.1A 30V TH

OMRON

D2F-01L

TP1 TP2 TP3 TP4 TP5


TP6 TP7 TP8 TP9 TP10
TP11 TP12 TP13 TP14
TP15 TP16 TP17 TP18
TP19

19

TEST POINT TH PAD 60


DRILL 35 DIAM, NO
PART TO ORDER

N/A

NO PART TO ORDER

Table continues on the next page...

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


Freescale Semiconductor, Inc.

73

Bill of materials: other components

Table C-2. BOM report for low-cost configuration (continued)


Part Reference

Quantity

Description

Manufacturer

Part Number

U1

IC MCU P2 MARCONI
32BIT 96K FLASH 16K
RAM 2.7-5.5V LQFP144

FREESCALE
SEMICONDUCTOR

PK40X256VLQ100

Y1

XTAL 32.768KHZ PAR


20PPM -- SMT

Citizen

CMR200T32.768KDZFUT

C.3 Bill of materials: other components

Table C-3. BOM report: other components (not included in schematics)

QUANTITY

DESCRIPTION

MANUFACTURER

PART NUMBER

Shunt-resistor 300

MAK-SAY

Enclosure

MAK-SAY

M310

Open-frame AC/DC power supply

XP Power

ECL05US03-T

Receptacle Cannon 9-pin

Tyco Electronics

1658609-4

Receptacle 10-pin, ribbon crimp

Tyco Electronics

1658622-1

3V battery

GP

CR2032

10 cm

Flat cable

any acceptable

1.5 m

Extension Cord 250V/16A

any acceptable

Outlet 250V/16A

any acceptable

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


74

Freescale Semiconductor, Inc.

Appendix D
Technical Specification
D.1 MK30X256 power meter specifications

Table D-1. MK30X256 power meter specifications

Parameter

Specification

Type of meter

Single phase residential

Type of measurement

4-quadrant

Metering algorithm

Fast Fourier Transform (FFT)

Accuracy (active & reactive energy)

IEC50470-3 Class B, 1%

Voltage range

85 ... 264 VRMS

Current range

0.02 ... 60 ARMS or 5(60) ARMS

Frequency range

47 ... 63 Hz

Meter constant (imp/kWh,imp/kVArh)

500, 1000, 2000, 5000, 10000

Functionality

V, A, kW, kVAr, kVA, kWh (import/export), kVArh (lead/lag), cos , Hz, time, date

Current sensor

Shunt-resistor 300

Energy output interface

Two high-efficiency red LEDs (active, reactive)

Open-collector output (optional only)

Optically-isolated, IC=50mA, VCEO=70V

User interface (HMI)

LCD, push button, user LED

Tamper detection

Two buttons, magnetometer (optional only)

Infrared interface (optional only)

For metering data reading (IEC1107)

Serial communication interface (RS232)

Optically-isolated, 19200Bd, 8 data bits, 1 stop bit, no parity

ZigBee interface (optional only)

RF 2.4 GHz 1322x-LPN internal daughter card (SE1.0 stack implemented)

Internal battery

3V, type CR2032

Total power consumption

< 1.4 W

Mechanical dimensions (w x l x h)

110 190 55

Weight (bare meter)

370 g

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


Freescale Semiconductor, Inc.

75

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


76

Freescale Semiconductor, Inc.

Appendix E
References
E.1 References

1. Kinetis K30 Device Summary Page, available at freescale.com


2. 3-Axis, Digital Magnetometer Data Sheet (MAG3110), available at freescale.com
3. 1322x-Low Power Node Reference Manual (1322xLPNRM), available at
freescale.com
4. 1322x Sensor Node Reference Manual (1322xSNRM), available at freescale.com
5. Wikipedia articles "AC power," "Current transformer," "Electricity meter," "Power
factor," "Rogowski coil," and "World Map: Voltage and Frequency," available at
en.wikipedia.org
6. Power FactorThe Basics, available at powerstudies.com
7. ZigBee Environment Demonstration (ZEDESDUG), available at freescale.com
8. FFT-based Algorithm for Metering Applications (AN4255), available at
freescale.com

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


Freescale Semiconductor, Inc.

77

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


78

Freescale Semiconductor, Inc.

Appendix F
F.1 Glossary
Alternating CurrentAC
Advanced Encryption StandardAES
Analog-to-Digital ConverterADC
Analog Front-EndAFE
Automatic Meter ReadingAMR
Bill of MaterialsBOM
Carrier Modulator TransmitterCMT
Common-Mode Rejection RatioCMRR
Cyclic Redundancy CheckCRC
Current TransformerCT
Direct CurrentDC
Digital-to-Analog ConverterDAC
Dual Flat No leadsDFN
Dhrystone Million Instructions Per SecondDMIPS
Digital Signal ProcessingDSP
Fast Fourier TransformFFT
Flex Timer ModuleFTM
General Purpose Input/OutputGPIO
Global Positioning SystemGPS
Graphical User InterfaceGUI
MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0
Freescale Semiconductor, Inc.

79

Glossary

Human Machine InterfaceHMI


Institute of Electrical and Electronics EngineersIEEE
Integrated CircuitIC
Integrated Interchip SoundI2S
Inter-Integrated CircuitI2C
Keyboard InterruptKBI
Land Grid ArrayLGA
Low Leakage Wake-up UnitLLWU
Low-Power TimerLPT
Light Emitting DiodeLED
Liquid Crystal DisplayLCD
Media Access ControlMAC
Magnetoresistive Random Access MemoryMRAM
Microcontroller UnitMCU
Object Identification SystemOBIS
Operational AmplifierOpAmp
Open CollectorOC
Periodic Interrupt TimerPIT
Printed-Circuit BoardPCB
Programmable Delay BlockPDB
Programmable Gain AmplifierPGA
Random Access MemoryRAM
Root Mean SquareRMS
Real Time ClockRTC
Successive Approximations RegisterSAR
Secured Digital Host ControllerSDHC
Serial Communication InterfaceSCI
MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0
80

Freescale Semiconductor, Inc.

Surface Mounted DeviceSMD


Switch Mode Power SupplySMPS
Serial Peripheral InterfaceSPI
Static Random Access MemorySRAM
Universal Asynchronous Receiver/TransmitterUART
Voltage ReferenceVREF
Zero-Cross DetectionZCD

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


Freescale Semiconductor, Inc.

81

MQX-Enabled MK30X256 Single-Phase Electricity Meter Reference Design, Rev. 0


82

Freescale Semiconductor, Inc.

How to Reach Us:


Home Page:
www.freescale.com

Web Support:
http://www.freescale.com/support

USA/Europe or Locations Not Listed:


Freescale Semiconductor
Technical Information Center, EL516
2100 East Elliot Road
Tempe, Arizona 85284
+1-800-521-6274 or +1-480-768-2130
www.freescale.com/support

Europe, Middle East, and Africa:


Freescale Halbleiter Deutschland GmbH
Technical Information Center
Schatzbogen 7
81829 Muenchen, Germany
+44 1296 380 456 (English)
+46 8 52200080 (English)
+49 89 92103 559 (German)
+33 1 69 35 48 48 (French)
www.freescale.com/support

Japan:
Freescale Semiconductor Japan Ltd.
Headquarters
ARCO Tower 15F
1-8-1, Shimo-Meguro, Meguro-ku,
Tokyo 153-0064
Japan
0120 191014 or +81 3 5437 9125
support.japan@freescale.com

Asia/Pacific:
Freescale Semiconductor China Ltd.
Exchange Building 23F
No. 118 Jianguo Road
Chaoyang District
Beijing 100022
China
+86 10 5879 8000
support.asia@freescale.com

For Literature Requests Only:


Freescale Semiconductor Literature Distribution Center
1-800-441-2447 or +1-303-675-2140
Fax: +1-303-675-2150
LDCForFreescaleSemiconductor@hibbertgroup.com

Document Number: DRM122


Rev. 0

Information in this document is provided solely to enable system and software


implementers to use Freescale Semiconductors products. There are no express or implied
copyright licenses granted hereunder to design or fabricate any integrated circuits or
integrated circuits based on the information in this document.
Freescale Semiconductor reserves the right to make changes without further notice to any
products herein. Freescale Semiconductor makes no warranty, representation, or
guarantee regarding the suitability of its products for any particular purpose, nor does
Freescale Semiconductor assume any liability arising out of the application or use of any
product or circuit, and specifically disclaims any liability, including without limitation
consequential or incidental damages. "Typical" parameters that may be provided in
Freescale Semiconductor data sheets and/or specifications can and do vary in different
applications and actual performance may vary over time. All operating parameters,
including "Typicals", must be validated for each customer application by customer's
technical experts. Freescale Semiconductor does not convey any license under its patent
rights nor the rights of others. Freescale Semiconductor products are not designed,
intended, or authorized for use as components in systems intended for surgical implant
into the body, or other applications intended to support or sustain life, or for any other
application in which failure of the Freescale Semiconductor product could create a
situation where personal injury or death may occur. Should Buyer purchase or use
Freescale Semiconductor products for any such unintended or unauthorized application,
Buyer shall indemnify Freescale Semiconductor and its officers, employees, subsidiaries,
affiliates, and distributors harmless against all claims, costs, damages, and expenses, and
reasonable attorney fees arising out of, directly or indirectly, any claim of personal injury
or death associated with such unintended or unauthorized use, even if such claims alleges
that Freescale Semiconductor was negligent regarding the design or manufacture of
the part.
RoHS-compliant and/or Pb-free versions of Freescale products have the functionality and
electrical characteristics as their non-RoHS-complaint and/or non-Pb-free counterparts.
For further information, see http://www.freescale.com or contact your Freescale
sales representative.