Sie sind auf Seite 1von 5

Project

Job Ref.

Section

Sheet no./rev.

Highland Engineering P.C.


700 Industrial Drive

Suite A
Cary, IL 60013

RSF

Date

Chk'd by

10/22/2010

Date

App'd by

Date

COLUMN BASE PLATE DESIGN (AISC360-05)


In accordance with the LRFD method
TEDDS calculation version 2.0.00;

1.5 "

19.0 "

W 12x96
250.0 kips

Bolt diameter - 0.8 "


Bolt embedment - 18.0 "
Flange/base weld - 0.3 "
Web/base weld - 0.2 "

2800.0 kip_in

20.0 kips

4.42 ksi
1.5 "
20.8 kips

Plan on baseplate

1.5 "

1.5 "

19 "

Elevation on baseplate

Design forces and moments


Axial force;

Pu = 250.0 kips; (Compression)

Bending moment;

Mu = 2800.0 kip_in

Shear force;

Fv = 20.0 kips

Eccentricity;

e = ABS(Mu / Pu) = 11.200 in

Anchor bolt to center of plate;

f = N/2 - e1 = 9.500 in

Column details
Column section;

W 12x96

Depth;

d = 12.700 in

Breadth;

bf = 12.200 in

Flange thickness;

tf = 0.900 in

Web thickness;

tw = 0.550 in

Baseplate details
Depth;

N = 22.000 in

Breadth;

B = 22.000 in

Thickness;

tp = 2.750 in

Design strength;

Fy = 36.0 ksi

Foundation geometry
Member thickness;

ha = 20.000 in

Dist center of baseplate to left edge foundation;

xce1 = 50.000 in

Dist center of baseplate to right edge foundation;

xce2 = 50.000 in

Dist center of baseplate to bot edge foundation;

yce1 = 50.000 in

Dist center of baseplate to top edge foundation;

yce2 = 50.000 in

Holding down bolt and anchor plate details


Total number of bolts;

Nbolt = 4

Bolt diameter;

do = 0.750 in

Project

Job Ref.

Section

Sheet no./rev.

Highland Engineering P.C.


700 Industrial Drive

Suite A
Cary, IL 60013

RSF

Date

10/22/2010

Chk'd by

Bolt spacing;

sbolt = 19.000 in

Edge distance;

e1 = 1.500 in

Minimum tensile strength of steel;

Fy = 36 ksi

Compressive strength of concrete;

fc = 4 ksi

Date

App'd by

Date

Strength reduction factors


Compression;

c = 0.65

Flexure;

b = 0.90

Weld shear;

v = 0.75

Plate cantilever dimensions


Area of base plate;

A1 = B N = 484.000 in2

Maximum area of supporting surface;

A2 = (N + 2 lmin) (B + 2 lmin) = 10000.000 in2

Nominal strength of concrete under base plate;

Pp = 0.85 f'c A1 min((A2 / A1), 2) = 3291.2 kips

Plate bending coefficient X;

X = (4 d bf) / (d + bf)2 min(1.0, Pu / (Pp c)) = 0.12

Plate bending coefficient ;

l = min(1, 2 (X) / (1 + (1 - X))) = 0.35

Bending line cantilever distance m;

m = (N - 0.95 d) / 2 = 4.967 in

Bending line cantilever distance n;

n = (B - 0.8 bf) / 2 = 6.120 in

Yield line theory cantilever distance n;

n = (d bf) / 4 = 3.112 in

Maximum bending line cantilever;

l = max(m, n, l n') = 6.120 in

Check eccentricity
Maximum bearing stress;

fp,max = 0.85 f'c c min((A2 / A1), 2) = 4.42 ksi

Maximum bearing pressure;

qmax = fp,max B = 97.24 kips/in


ecrit = N / 2 - Pu / (2 qmax) = 9.715 in

Critical eccentricity;

e > ecrit so loads cannot be resisted by bearing alone. Therefore consider as a large moment
Plate dimensions adequate as (f + N/2)2 >= (2 Pu (e + f))/qmax and a real solution for bearing length exists
Bearing length - quadratic solution 1;

Y1 = (f + N/2) + ((f + N/2)2 - (2 Pu (e + f))/qmax) = 38.215 in

Bearing length - quadratic solution 2;

Y2 = (f + N/2) - ((f + N/2)2 - (2 Pu (e + f))/qmax) = 2.785 in

Bearing length;

Y = min(Y1, Y2) = 2.785 in

Tension force in bolts;

Tu = qmax Y - Pu = 20.8 kips

Max tension in single bolt;

Trod = Tu / (Nbolt/2) = 10.4 kips

Base plate yielding limit at bearing interface


Required plate thickness;

tp,req = ((4 fp,max Y (l - Y/2))/(b Fy)) = 2.680 in


PASS - Thickness of plate exceeds required thickness

Base plate yielding limit at tension interface


Distance from bolt CL to plate bending lines;

x = abs(l - e1) = 4.620 in

Plate thickness required;

tp,req = 2.11 ((Tu x)/(B Fy)) = 0.736 in


PASS - Thickness of plate exceeds required thickness

Frictional shear resistance


Steel / concrete friction coefficient;

= 0.4

Frictional shear resistance;

Vn = min(v qmax Y, v 0.2 f'c Y B, v 800psi Y B) =


36.77 kips
PASS - Frictional shear resistance exceeds applied shear

Project

Job Ref.

Section

Sheet no./rev.

Highland Engineering P.C.


700 Industrial Drive

Suite A
Cary, IL 60013

RSF

Date

10/22/2010

Chk'd by

Date

App'd by

Date

Flange weld
Flange weld leg length;

tfw = 0.2500 in

Tension capacity of flange;

Ptf = bf tf Fy = 395.3 kips

Force in tension flange;

Ftf = Mu / (d - tf) - Pu (bf tf) / Acol = 139.9 kips

Critical force in flange;

Ff = min(Ptf, max(Ftf, 0kips)) = 139.9 kips

Flange weld force per in;

Rwf = Ff / (2 bf - tw) = 5.9 kips/in

Electrode classification number;

FEXX = 70.0 ksi

Nominal weld stress;

Fw = v 0.60 FEXX (1.0 + 0.5 (sin(90deg))1.5) = 47.2500ksi

Design strength of weld per in;

Rnf = Fw twf / (2) = 10.4 kips/in


PASS - Available strength of flange weld exceeds force in flange weld

Longitudinal web weld


tww = 0.2500 in

Web weld leg length;


Web weld force per in;

Rwl = Fv / (2 (d - 2 tf)) = 0.9174 kips/in

Electrode classification number;

FEXX = 70.0 ksi

Nominal weld stress;

Fw = v 0.60 FEXX (1.0 + 0.5 (sin(90deg))1.5) = 47.2500ksi

Design strength of weld per in;

Rnl = Fw tww / (2) = 8.4 kips/in

PASS - Available strength of longitudinal web weld exceeds force in longitudinal web weld
ANCHOR BOLT DESIGN (ACI318-08)
TEDDS calculation version 2.0.00

Anchor bolt geometry


Type of anchor bolt;

Cast-in headed end bolt anchor

Diameter of anchor bolt;

da = 0.75 in

Number of bolts in x direction;

Nboltx = 2

Number of bolts in y direction;

Nbolty = 2

Total number of bolts;

ntotal = (Nboltx 2) + (Nbolty - 2) 2 = 4

Total number of bolts in tension;

ntens = (NboltN 2) + (Nbolty - 2) = 2

Spacing of bolts in x direction;

sboltx = 19 in

Spacing of bolts in y direction;

sbolty = 19 in

Number of threads per inch;

nt = 10

Effective cross-sectional area of anchor;

Ase = / 4 (da - 0.9743 in / nt)2 = 0.334 in2

Embedded depth of each anchor bolt;

hef = 18 in

Material details
Minimum yield strength of steel;

fya = 105 ksi

Minimum tensile strength of steel;

futa = min(1.9 fya, 125ksi) = 125 ksi

Compressive strength of concrete;

fc = 4 ksi

Concrete modification factor;

= 1.00

Strength reduction factors


Strength reduction factor tension of steel element; t,s = 0.75
Strength reduction factor shear of steel element; v,s = 0.70
Strength reduction factor concrete tension;

t,c = 0.65

Strength reduction factor concrete shear;

v,c = 0.70

Project

Job Ref.

Section

Sheet no./rev.

Highland Engineering P.C.


700 Industrial Drive

Suite A
Cary, IL 60013

RSF

Date

Chk'd by

10/22/2010

Date

App'd by

Date

Steel strength of anchor in tension (D.5.1)


Nominal strength of anchor in tension;

Nsa = Ase futa = 41.81 kips

Steel strength of anchor in tension;

Nsa = t,s Nsa = 31.36 kips


PASS - Steel strength of anchor exceeds max tension in single bolt

1' 7.0"

3' 4.5"

Check concrete breakout strength of anchor bolt in tension (D.5.2)

3' 4.5"

1' 7.0"

1' 6"

1' 8"

3' 4.5"

20.84 kips

3' 4.5"

8' 4"

Plan on foundation

Section A-A
Concrete breakout - tension

Stength reduction factor;

t = 0.65

Coeff for basic breakout strength in tension;

kc = 24

Breakout strength for single anchor in tension;

Nb = 16 (f'c 1 psi) hef5/3 1 in1/3 = 125.10 kips

Projected area for groups of anchors;

ANc = 3942 in2

Projected area of a single anchor;

ANco = 9 hef2 = 2916 in2

Min dist center of anchor to edge of concrete;

ca,min = 40.5 in

Mod factor for groups loaded eccentrically;

ec,N = min(1 / (1 + ((2 e'N) / (3 hef))), 1) = 1.000

Modification factor for edge effects;

ed,N = 1.0 = 1.000

Modification factor for no cracking at service loads; c,N = 1.250


Modification factor for uncracked concrete;

cp,N = 1.000

Nominal concrete breakout strength;

Ncbg = ANc / ANco ed,N c,N cp,N Nb = 211.40 kips

Concrete breakout strength;

Ncbg = t,c Ncbg = 137.41 kips


PASS - Breakout strength exceeds tension in bolts

Pullout strength (D.5.3)


Net bearing area of the head of anchor;

Abrg = 1.5 in2

Mod factor for no cracking at service loads;

c,P = 1.4000

Pullout strength for single anchor;

Np = 8 Abrg f'c = 48.00 kips

Nominal pullout strength of single anchor;

Npn = c,P Np = 67.20 kips

Pullout strength of single anchor;

Npn = t,c Npn = 43.68 kips


PASS - Pullout strength of single anchor exceeds maximum axial force in single bolt

Project

Job Ref.

Section

Sheet no./rev.

Highland Engineering P.C.


700 Industrial Drive

Suite A
Cary, IL 60013

RSF

Date

10/22/2010

Chk'd by

Date

App'd by

Date

Side face blowout strength (D.5.4)


As hef <= 2.5 min(ca1, ca2) the edge distance is considered to be far from an edge and blowout strength need not be
considered