Introduction
Solar Thermal Power Plants (STPP) can be used to generate electricity in a manner
similar to that of a traditional fossil fuel plant in that superheated steam is used to drive a
turbine-generator. The inherent disadvantage of solar plants is that the energy source,
solar radiation, is cyclic (daily and seasonally) and intermittent. This may be addressed
by the use thermal energy storage to allow the plants electricity generation to follow the
demand rather than the instantaneous solar flux.
The use of molten salt as the heat transfer fluid within a solar thermal power plant is
investigated. The molten salt provides the energy link between the concentrated solar
flux at the receiver and the steam generated for the turbine generator as shown in Figure
1. Molten nitrate salt is used as both the heat transfer fluid and the storage medium, with
heat gained from the concentrated solar flux at the receiver, and heat rejected at the
steam generator. The steam generator supplies steam at a temperature close to the peak
salt temperature of 565oC, this allows operation of the Rankine cycle turbine at conditions similar to a conventional fossil fuel plant. The peak salt temperature given is that
of the Solar Tres 15 MWe plant in Spain that incorporates 16 hours of full power storage
requirements [Mills 2004]. Both salt storage tanks remain above the freezing point of
the molten salt.
Figure 1. Schematic of the Solar Tres solar thermal power plant with molten salt energy storage
[Medrano et al 2010]
The use of molten nitrate salt (60%w NaNO3, 40%w KNO3) is investigated with respect to its heat transfer characteristics at the high Reynolds and Nusselt numbers found
in the receiver of a practical solar thermal power plant. A review of the literature has
provided data for this and other molten salts but only below the required Reynolds and
Nusselt number ranges.
The validity of the assumption of the heat transfer fluids constant properties, in particular dynamic viscosity, is reviewed with regard to convective heat transfer
calculations when applied to STPP applications. The hydraulic and thermal boundary
layers are considered for flow in both tubes and annuli. The velocity and temperature
profiles are developed to determine the sensitivity to the constant property assumption.
2. Nomenclature
Symbol
Unit
Description
m2
Area
Bi
Biot number
cp
J.kg-1.K-1
Diameter
W.m-2.K-1
J.kg-1
Specific enthalpy
W.m-1.K-1
Thermal conductivity
Length
Nu
Nusselt number
Pr
Prandtl number
W.m-2
Heat flux
Radius
Re
Reynolds number
Temperature
m.s-1
Velocity
m3
Volume
mm
Pa.s
Dynamic viscosity
m2.s-1
Kinemetic viscosity
Roman Symbols
C or K
Greek Symbols
kg.m-3
Density
r, q, z
Cylindrical coordinates
x, y, z
Cartesian coordinates
Characteristic
Diameter
Electric
Fluid
Inside
Liquid
Outside
th
Thermal
Weight, wall
Miscellaneous
Subscripts
Abbreviations
DNI
HTF
MS
Molten Salt
STPP
Melted salt can be used over a temperature range of 260 oC to 621 oC.
Fluid salt property formulas as a function of temperature are valid for 300 oC
< T < 600 oC.
Equation (1)
1950
Density (kg/m3)
1900
1850
1800
1750
1700
1650
250
300
350
400
450
500
550
600
650
Temperature (C)
Equation (2)
1550
1540
1530
1520
1510
1500
1490
250
300
350
400
450
500
550
600
650
Temperature (C)
Figure 3. Specific Heat at Constant Pressure versus Temperature for liquid 60%w NaNO3/40%w
KNO3
1.20 10
1.474 10
+ 2.281 10
Equation (3)
0.0035
0.0030
0.0025
0.0020
0.0015
0.0010
0.0005
0.0000
250
300
350
400
450
500
550
600
650
Temperature (C)
Figure 4. Dynamic Viscosity versus Temperature for liquid 60%w NaNO3/40%w KNO3
Equation (4)
0.5600
0.5500
0.5400
0.5300
0.5200
0.5100
0.5000
0.4900
250
300
350
400
450
500
550
600
650
Temperature (C)
Figure 5. Thermal Conductivity versus Temperature for liquid 60%w NaNO3/40%w KNO3
The Prandtl number (dimensionless) is a function of dynamic viscosity (Pa.s), specific heat at constant pressure (J.kg-1.K-1), and thermal conductivity (w.m-1.K-1). It is
calculated using Zavoico [2001] data:
=
.
Equation (5)
12.0
10.0
8.0
6.0
4.0
2.0
0.0
250
300
350
400
450
500
550
600
650
Temperature (C)
Figure 6. Prandtl Number versus Temperature for liquid 60%w NaNO3/40%w KNO3
The kinematic viscosity (m2.s-1) is a function of dynamic viscosity (Pa.s) and density (kg.m-3) and calculated using Zavoico [2001] data:
=
Equation (6)
2.0E-06
1.8E-06
1.6E-06
1.4E-06
1.2E-06
1.0E-06
8.0E-07
6.0E-07
4.0E-07
2.0E-07
0.0E+00
250
300
350
400
450
500
550
600
650
Temperature (C)
Figure 7. Kinematic Viscosity versus Temperature for liquid 60%w NaNO3/40%w KNO3
It is noted that the thermodynamic properties of the molten salt, r, cp, m, kf, Pr and
n all vary with temperature as shown in Figure 2 through Figure 7. The variations, as
shown in Table 1, are typical of liquids as described by Kays et al [2005]:
For most liquids the specific heat and thermal conductivity are relatively independent of temperature, but the viscosity decreases very markedly with temperature.
This is especially so for oils, but even for water the viscosity is very temperature
dependent. The density of liquids, on the other hand, varies little with temperature.
The Prandtl number of liquids varies with temperature in much the same manner as
viscosity.
Methods available to account for property variations include the reference temperature and property ratio methods Kays et al [2005]. The reference temperature method
evaluates the properties at a chosen temperature, typically the mean of the surface and
fluids mixed mean temperature. The property ratio method evaluates all properties at the
fluids mixed mean temperature, and then those variable properties are also evaluated at
the surface temperature. A function of the variable properties ratio is then used to
correct those evaluated at the mixed mean temperature. A means for correcting for the
constant property assumption becomes increasingly important when high temperature
10
differentials are present between, say, the tube wall of a STPP exposed to a high solar
flux and the heat transfer fluid. Both methods will be used in this project.
### comment on constant property assumption used to de-couple energy equation
from continuity and moment equations find source. See page 68 of white ####
Table 1. Property changes over operating temperature range
Property
Symbol
Units
Value at
Value at
300oC
600oC
to 600oC
Density
kg.m-3
1899
1708
-10%
Specific heat
cp
J.kg-1.K-1
1495
1546
+3.4%
Dynamic
Pa.s
0.0033
0.0010
-70%
kf
W.m-1.K-1
0.500
0.557
+11%
9.8
2.8
-71%
m2.s-1
1.7*10-6
5.8*10-7
-66%
viscosity
Thermal
conductivity
Prandtl
number
Kinematic
viscosity
The thermodynamic properties are those of Zavoico [2001] as they are specific to
liquid 60%w NaNO3/40%w KNO3. Properties at other compositions as well as other
salts are available in Janz et al [1972].
11
Site
Seville
Daggett
Carnarvon
Spain
USA
South Africa
Latitude ( )
37.42
34.87
-30.97
Longitude (o)
-5.9
-116.8
22.13
Altitude (m)
31
588
1309
900
950
1000
2089
2791
2995
The high temperature and exergy of the source of solar radiation makes it a valuable
energy resource. However, the low flux density at the earths surface as shown in Table
2 makes it a poor candidate for power generation applications when used without optical
concentration. The use of optical concentrations allow the generation of HTF temperatures useful for thermodynamic cycles
A concentrated solar flux density of nominally 1 MW.m-2 was used at the Solar Two
STPP with operational variations between 240 kW.m-2 at the outlet salt temperature of
565oC, and 850 kW.m-2 at the inlet salt temperature of 290oC [Vant-Hull 2002]. The
Solar Two flux densities will be used as the basis for this report. Note that the central
receiver flux density is three orders of magnitude greater than the DNI.
The design of central receiver tubes for STPP with molten salt HTF requires, among
others, consideration of the operating temperatures, corrosive characteristics of the fluid,
and thermal cycling. The cycling of Solar Two STPP with a 30 year design life includes
1.0x104 deep temperature cycles (nightly draining of the central receiver and cooling to
ambient temperature), and 3.0x104 shallow temperature cycles (cloud transients etc.).
For this service the central receiver tubes are 21 mm outside diameter, 1.25 mm wall
12
[Liao et al 2014]. Variation in velocity may be used by STPP to control the salt outlet
temperature and absorbed flux [Vant-Hull 2002], therefore, a range of average molten
salt velocities from 1.0 to 5.0 m.s-1 is used as the basis for this report.
The physical characteristics of the STPP used for this project are given in Table 3.
Add fluid temperature for molten salt, and flux/molten salt temperature matches.
Table 3. STPP project physical characteristics
Project Characteristic
Symbol
Units
Value
Tube material
Do
mm
21.0
mm
1.25
Di
mm
18.5
m.s-1
1.0 V 5.0
290 T 565
W.m-2
240 q 850
fluid temperature
The thermal conductivity (W.m-1.K-1) of the 316 stainless steel tubes is a function of
temperature (oC) and is calculated using ASME [2010] data as:
= 0.01431
+ 13.96
13
Equation (7)
30.0
25.0
20.0
15.0
10.0
5.0
0.0
0
100
200
300
400
500
600
Temperature (oC)
Figure 8. Thermal Conductivity versus Temperature for 316 stainless steel [ASME 2010]
14
700
800
Equation (8)
The Reynolds number range for this project, with the follow conditions:
1.0
5.0 .
= 18.5 10
5.8 10
1.7 10
is:
1.1 10
1.6 10
The upper limit of ReD = 1.6*105 occurs at the upper velocity (V = 5.0 m.s-1) and
lowest kinematic viscosity (n = 5.8*10-7) corresponding to 600oC. Considering only the
600oC conditions but at the lower velocity (V = 1.0 m.s-1), the Reynolds number is
reduced to 20% or 3.2*104.
The project Prandtl and Reynolds number ranges are shown in Table 4. The flow is
fully turbulent for all cases with ReD > 4000.
The upper range of ReD is, in part, the motivation for this project. Published data
for heat transfer applications with molten salts are limited to ReD 50000. A survey of
available experimental data for molten salts was performed by Wu et al [2012] and
summarized in Table 5. The published data includes Prandtl numbers that cover the
range of this project, however, the Reynolds number maximum is nominally 30% of that
required for this project.
An aim of this project is to investigate the available Nusselt number correlations.
However, to facilitate order of magnitude calculations a preliminary Nusselt number
range is determined. A widely used Nusselt number correlation is the Dittus-Boelter
[Winterton 1998] equation:
.
= 0.0243
15
Equation (9)
The Nusselt number range for this project is of the order of 62 (Re = 1.1*104, Pr =
2.8) to 881 (Re = 1.6*105, Pr = 9.8). It is noted that the high heat flux, high Reynolds
number cases that are of interest for this project have a Pr = 2.8 at 600oC, therefore, the
Nusselt number of greatest interest is nominally 534 (Re = 1.6*105, Pr = 2.8). Consideration will also be given to the high heat flux, low Reynolds number case at full
temperature (600oC). The resulting internal convection coefficients are calculated by:
=
Equation (10)
The resulting internal convection coefficients range is 1866 to 26525 W.m-2.K-1 (kf
= 0.557 W.m-1.K-1, Di = 18.5 mm). The convection coefficient corresponding to the
Nusselt number of 534 is 16077 W.m-2.K-1.
The STPP designers choice of the bulk molten salt tube velocity, and hence Reynolds number, is often a consideration of pressure loss and its impact on the pump energy
consumption. However, for heat transfer applications the Nusselt number is also a
function of the Reynolds number. It will be shown that the velocity selection and its
ultimate impact on the Nusselt number and convective heat transfer coefficient strongly
influences the tube wall to bulk fluid temperature differential. For this reason, the
velocity selected impacts the validity of the constant fluid property assumption.
The nominal Nusselt and convection coefficient values for this project are given in
Table 6.
Table 4. Prandtl and Reynolds number ranges for project
Salt
Prandtl range
Reynolds range
1.1*104 Re 1.6*105
For a fluid temperature of 600oC:
Re = 1.6*105 at 5.0 m.s-1
Re = 3.2*104 at 1.0 m.s-1
Table 5. Prandtl and Reynolds number ranges for published molten salt data [Wu et al 2012]
Salt
Prandtl range
Reynolds range
16
Lithium Nitrate
Flinak
LiF-BeF2-ThF4-UF4
NaBF4-NaF
Table 6. Nusselt number and convection coefficient nominal ranges for project
Characteristic
Units
Range
Primary value
Nusselt number
Convection coefficient
W.m-2.K-1
17
Project Characteristic
Symbol
Units
Value
mm
0.0015 (new)
0.045 (corroded)
0.9 [Kolb 2011]
e/Di
18
8.1*10-5 (new)
2.4*10-3 (corroded)
5*10-2 [Kolb 2011]
Fanning friction factor
The Fanning friction factor is a function of the Reynolds number and relative surface roughness. The Moody diagram [Bhatti Shah 1987] is used with the project data
shown in Figure 9. It is seen that the new tube can be classified as hydraulically smooth
for all operating cases. However, the corroded tube operates in the transition region,
neither hydraulically smooth nor completely rough. The Kolb [2011] tube operates in
the transition and fully turbulent region.
Figure 9. Moody diagram [Bhatti Shah 1987] with new and corroded tube characteristics (UPDATE
PICTURE and ADD KOLB friction)
Bhatti and Shah [1987] describe the three flow regimes as:
19
In the hydraulically smooth regime, e is so small that the sand grains are contained within the laminar sublayer. Hence f is not affected by e; in other words, f =
f(Re). In the transition regime, the sand grains extend partly outside the laminar
sublayer, exerting an additional resistance to the flow, in the nature of a profile drag.
This causes the friction coefficient to depend on e/r as well as on Re, i.e., for the
transition regime f = f(e/r, Re). Finally, in the completely rough regime, all sand
grains reach outside the laminar sublayer, disrupting it completely. For this situation, the friction coefficient must depend on the size of the sand grain alone, i.e., f =
f(e/r).
Various Nusselt number correlations have been developed for fully developed turbulent flow in circular duct for smooth and fully rough regimes. The cases shown to
exist within the transition between smooth and fully rough regimes will be treated be as
smooth with the following empirical correction, and as shown in Figure 10, to account
for the effect of roughness on turbulent flow (20000 < Re < 200000) [Norris 1970]:
=
= (4)
2.5
Equation (11)
> 2.5
Equation (12)
Where
= 0.68
= 1
1 <
>6
Equation (13)
Equation (14)
Due to the exponent n varying between 0.68 (Pr = 1) and 1.0 (Pr = 6), the effect of
roughness is more pronounced at higher Prandtl number. However, as shown in Figure
10, this trend is inconsistent.
20
Figure 10. Effect of Prandtl number on heat transfer increase ratio for 20000 < Re < 200000 [Norris
1970]
The Nusselt number for a turbulent flow is sensitive to the surface roughness. As an
estimate of the sensitivity, at Re = 104 and Pr = 0.7, the local Nusselt number varies from
200 to 400 as shown in Figure 11. The doubling of the Nusselt number by variation in
only the relative surface roughness is indicative of the sensitivity of this characteristic.
The relative surface roughness of Figure 11 is from smooth to 1*10-2 which is within the
project range of smooth to 5*10-2.
Figure 11. Local Nusselt number as a function of relative surface roughness and Prandtl number in
the turbulent region [Nellis Klein 2008]
It is noted for this project, the Prandtl number range is 9.8 to 2.8 for 300oC to 600oC
respectively, with Pr < 6.0 for fluid temperatures greater than approximately 375oC.
21
22
Equation (15)
Equation (16)
For this application, the inside and outside convection coefficients differ by orders
of magnitude so only the inside surface is considered. Therefore, the characteristic
length for the project is:
=
= 4.9
Equation (17)
2
The tube thermal conductivity, as shown in Figure 8, is in the 15 to 25 W.m-1.K-1
range. The internal convection coefficient, as yet unknown, is assumed to be in the
range of 1866 to 26525 W.m-2.K-1 (Table 6). The resulting Biot number for this project
is in the range of 0.36 to 8.6. Using the projects nominal internal convection coefficient
of 16000 W.m-2.K-1 (Table 6), and tube thermal conductivity of 22.2 W.m-1.K-1 (at
575oC), the Biot number is 3.5.
For Bi << 0.1, the resistance to conduction in the solid is much less than the resistance to convection across the solid/fluid boundary [Incropera DeWitt 2001]. That is,
a relatively uniform temperature occurs throughout the solid while a rapid temperature
differential occurs within the fluid adjacent to the wall. Conversely, as Bi , a large
temperature change occurs in the solid while the surface and fluid temperature are
23
Figure 12. Temperature distribution for limiting Biot numbers [similar to figure 3.9 of Yener]
Another means of determining the temperature difference between the tube inner
wall and that of the fluid is that of Mackowski [2015]. The Mackowski [2015] model as
used by Wyatt [2012] provides an analytical model for a long, annular cylinder with
temperature variation in both r and q, convection on the internal and external surfaces,
and collimated thermal radiation incident on the outside of the cylinder, as shown in
Figure 13.
24
Figure 13. Long, thick walled cylinder with external collimated incident radiation, radial and
circumferential conduction, and, internal and external convection [Wyatt 2012]
The Mackowski [2015] model was used to determine the temperature difference between the tube inner wall and the bulk fluid temperature. The base case was performed
as well as considering the incident flux range (240 kW.m-2 to 850 kW.m-2) and internal
convection coefficient (20%). The base case uses the Solar Two STPP characteristics
of an incident flux of 240 W.m-2 with a molten salt bulk fluid temperature of 565oC
[Vant-Hull 2002] and an internal convection coefficient of 16000 W.m-2.K-1. The results
using the Wyatt [2012] code is shown in Figure 14 and the results for all cases are in
Table 8.
A weakness of the Mackowski [2015] model for this application is the assumption
of a uniform external convection coefficient. The STPP application will insulate the rear
of the tubes to prevent convective heat loss from this surface. Similarly, as discussed by
Wyatt [2012], the STPP tubes are arranged to form a panel. The panel arrangement
allows the peak tube temperature to occur at the crown as shown in Figure 14, however,
the crevice between tubes results in a second peak tube temperature to occur at nominally q = p/2 radians from the tube crown. These will not be considered further in this
project.
25
Figure 14. Tube temperature profile with an incident flux 240000 W/m2, molten salt bulk temperature 565oC, internal convection coefficient 16000 W.m-2.K-1
26
Table 8. Tube and molten salt temperatures with internal convection coefficient 16000W.m-2.K-1 +/20%
Case
1H
2H
3H
4H
5H
6H
7H
8H
9H
Base
Incident flux
kW.m-2
240
545
850
240
545
850
240
545
850
Internal convection
kW.m-2.K-1
16.0
16.0
16.0
19.2
19.2
19.2
12.8
12.8
12.8
596
636
676
593
630
667
600
645
690
581
603
624
579
597
615
585
612
638
15
33
52
14
33
52
15
33
52
16
38
59
14
32
50
20
47
73
coefficient
Tube outside maximum
temperature
Tube inside maximum
temperature
Through wall temperature
differential (max)
Inside wall to fluid temperature differential (max)
For all cases:
Tube outside diameter: 21 mm
Tube wall thickness: 1.25 mm
Tube conductivity: 22.2 W.m-1.K-1
Absorptivity of tube outer surface: 0.95
External convection coefficient: 10 W.m-2.K-1
External bulk fluid (air) temperature: 27oC
Internal bulk fluid (molten salt) temperature: 565oC
The Mackowski [2015] model supports the previous Biot number analysis. That is,
the temperature difference from the outside of the tube through to the bulk fluid temperature is not dominated by either the tube wall temperature differential (Bi) nor
the inner tube wall to bulk fluid temperature differential (Bi0). The results show the
overall temperature differential is nominally evenly split between the tube wall and
molten salt fluid.
The Mackowski [2015] model shows the through wall temperature, and the tube
outside maximum temperature are dependent upon the incident flux. Hence the significance of controlling the flux as a function of the molten salt temperature in order to
remain within the temperature limits of the tube material. As previously noted, this was
27
a characteristic of the Solar Two STPP with flux to molten salt operational variations
between 240 kW.m-2 at the outlet salt temperature of 565oC, and 850 kW.m-2 at the inlet
salt temperature of 290oC [Vant-Hull 2002]. However, it is the tube inside wall to bulk
fluid temperature differential that is of significance to this project due to its influence on
the molten salt fluid properties.
For a given incident flux, the Mackowski [2015] model shows the greatest tube inside wall to bulk fluid temperature differential corresponding to the lowest internal
convection coefficient. This is as expected as the internal convection coefficient is
indicative of the fluids ability to remove the heat from the tube wall, however, as this
differential temperature increases, the constant property assumption is weakened.
For the incident flux of 240 kw.m-2, and the convection coefficient varying between
12.8 kW.m-2.K-1 (-20%) through 16.0 kW.m-2.K-1 to 19.2 kW.m-2.K-1 (+20%), the
internal tube wall to bulk fluid differential temperatures are 20, 16, 14oC respectively.
This project initially assumed that the high Reynolds number may be deviating from
the Nusselt number correlations. The results thus far are indicative of the reverse, that
is, low Reynolds numbers are prone to higher temperature differentials within the fluid
and hence greater fluid property variation. This projects other initial assumption that
high heat flux may also deviate from the Nusselt number correlations is supported by the
Mackowski [2015] model results.
The Mackowski [2015] model was again used to determine the temperature difference between the tube inner wall and the bulk fluid temperature. The cases were
repeated with the same incident flux range (240 kW.m-2 to 850 kW.m-2), however, the
internal convection coefficient was changed to 4400 W.m-2.K-1 20%. The reduced
convection coefficient base case again uses the Solar Two STPP characteristics of an
incident flux of 240 W.m-2 with a molten salt bulk fluid temperature of 565oC [VantHull 2002] but with an internal convection coefficient of 4400 W.m-2.K-1. The results
using the Wyatt [2012] code is shown in Figure 15 and the results for all cases are in
Table 9.
28
Figure 15. Tube temperature profile with an incident flux 240000 W/m2, molten salt bulk temperature 565oC, internal convection coefficient 4400 W.m-2.K-1
Table 9. Tube and molten salt temperatures with internal convection coefficient 4400W.m-2.K-1 +/20%
Case
1L
2L
3L
29
4L
5L
6L
7L
8L
9L
Base
-2
Incident flux
kW.m
240
545
850
240
545
850
240
545
850
Internal convection
kW.m-2.K-1
4.40
4.40
4.40
5.28
5.28
5.28
3.52
3.52
3.52
634
725
815
626
705
785
647
753
860
620
693
765
612
673
734
633
722
810
14
32
50
14
32
51
14
31
50
55
128
200
47
108
169
68
157
245
coefficient
Tube outside maximum
temperature
Tube inside maximum
temperature
Through wall temperature
differential (max)
Inside wall to fluid temperature differential (max)
For all cases:
Tube outside diameter: 21 mm
Tube wall thickness: 1.25 mm
Tube conductivity: 22.2 W.m-1.K-1
Absorptivity of tube outer surface: 0.95
External convection coefficient: 10 W.m-2.K-1
External bulk fluid (air) temperature: 27oC
Internal bulk fluid (molten salt) temperature: 565oC
The Mackowski [2015] model results with the internal convection coefficient of
4400 W.m-2.K-1 was an academic exercise only. The tube outside and inside temperatures ranges are 626oC to 860oC and 612oC to 810oC respectively, both of which are
impractical. The oxidation temperature, or minimum continuous service temperature
without excessive scaling in air, for AISI 316 stainless steel is 870oC [Siebert et al
2008]. Similarly, the maximum temperature limit for SA-213 TP316 seamless tubing in
ASME section I application is 816oC [ASME 2010]. However, the reported maximum
temperature limit for molten nitrate salt (60%w NaNO3, 40%w KNO3) is approximately
621oC [Zavoico 2001].
Although impractical, the results of Table 9 (hi = 4400 W.m-2.K-1 20%) are informative when compared to Table 8 (hi = 16000 W.m-2.K-1 20%). By changing the
molten salt velocity from nominally 1.0 m.s-1 to 5.0 m.s-1 to increase the internal convec-
30
tion coefficient, the outside tube wall temperature decreased from 634oC (Case 1L) to
596oC (Case 1H). While the tube material temperature is clearly an important design
consideration, the inside wall to fluid temperature differential is of importance to this
project due to its role in the fluid properties. Similarly, the inside wall to fluid temperature differential decreased from 55oC (Case 1L) to 16oC (Case 1H).
The use of the molten salt velocity is significant to control the tube wall temperature
as shown by the above results and Vant-Hull [2002]. However, it is also significant
when selecting the convection correlation model due to the influence on the range of
fluid properties. These convection correlation models will be investigated in the next
section.
31
Equation (18)
The determination of the Nusselt number from a correlation allows the convection
heat transfer coefficient to be calculated, and hence the heat transfer:
= . (
Equation (19)
= 0.0241
Equation (20)
The widely presented form of the correlation for heating [Incropera DeWitt 2001,
Kreith Bohn 1986, Burmeister 1983] is:
= 0.023
Equation (21)
= 0.024
Equation (22)
For:
1.0 10 <
< 1.2 10
32
Equation (23)
0.7 <
< 120
Equation (24)
Burmeister [1983] noted that the correlation is reasonably accurate when the wall
temperature does not exceed the fluid mixing-cup temperature by more than 5oC for
liquids or 55oC for gases. The properties are evaluated at the average local film temperature according to Burmeister [1983] while Winterton [1998] recommends using the
bulk fluid temperature which is more convenient. The point is moot assuming the
difference between the fluid and wall temperature is limited to 5oC.
Burmeister [1983] claims the Dittus-Boilter correlation results can be 20% high for
gases and up to 40% low for water at high Reynolds number.
Equation (25)
For:
10 <
< 10
Equation (26)
0.6 <
< 100
Equation (27)
Equation (28)
It is noted that the published coefficient varies from the 0.027 including 0.023
[Burmeister 1983] and 0.026 [Bird et al 2007].
All properties are evaluated at the bulk fluid temperature except for ms which is to
be evaluated at the pipe surface temperature.
The significance of the variations in fluid properties, as noted by Sieder and Tate
[1936], is:
The theoretical formulas, for heat transfer to fluids in viscous flow in tubes,
do not take into consideration the effect of a radial temperature gradient on the distribution of the axial and radial components of the velocity. Because of the
33
Figure 16. Distortion of laminar velocity profile in a heated or cooled tube when the viscosity of the
fluid depend on temperature (a) parabolic profile (b) heating of liquid (c) cooling of liquid [Kays
Perkins 1985]
34
considered. Petukhov [1970] also noted the practical difficulties in obtaining experimental data at high temperatures, large heat fluxes, and high pressures.
The Petukhov [1970] correlation is given in heat transfer texts including Incropera
and DeWitt [2001] and Kreith and Bohn [1986]. It is noted that Incropera and DeWitt
[2001] utilized the simplified correlation (Equation aa) while Kreith and Bohn [1986]
use the more accurate relationship (Equation bb).
2
Equation
) 2
1)
(bb29)
Where:
1
(1.82
4
With a claimed error of 1% for:
=
1.64)
10 <
Equation (30)
< 5 10
Equation (31)
< 200
Equation (32)
0.5 <
1.07 + 12.7 2
Equation
(
1)
(aa33)
The latter formed the basis for the correlations of Gnielinski [1976].
35
The correlations attributed to Gnielinski as presented by Bhatti and Shah [1987] are
a modification of Petukhov [1970] in order to extend the Reynolds number range from
fully developed turbulent flow range 104 Re 5*106 to include the transition range
2300 < Re 104:
2
1000)
1 + 12.7 2
EquationA
(34)
1)
= 0.0214(
100)
280)
Equation (35)
= 0.012(
EquationB
(36)
Although not included by Kays et al [2005], Incropera and DeWitt [2001], or Bhatti
and Shah [1987], Gnielinski [1976] also published another equation to account for the
temperature dependence of the properties:
=
1000)
1 + 12.7 2
1)
EquationC
(37)
For:
2300 <
< 10
Equation (38)
0.5 <
< 724
Equation (39)
Equation (40)
Gnielinski [1976] validates the correlation with gases flowing through pipes with
small temperature differences between the average gas temperature and the wall
temperature Furthermore, for liquids:
For heat transfer between liquids and solid wall it is possible to consider the
dependence of the properties on temperature by the ratio of Prandtl numbers in
Equation C21 at the average liquid temperature and the wall temperature, because
only the viscosity of the liquid depends very much on temperature, and large temperature differences are not usual for convective heat transfer.
Of the Gnielinski [1976] correlations available, those used within the molten salt literature are varied. Liao et al [2014] used the correlation without properties correction
36
(Equation 18), Wu et al [2012] and Bin et al [2009] used the liquid approximation but
with the Prandtl ratio correction (a combination of Equation C20 and Equation C21).
The author is not aware of the use of Equation C21 with the temperature dependent
properties correction.
The application of the Gnielinski [1976] correlation to a liquid with a large temperature difference between the wall and mean fluid will be examined as this was not
considered usual.
## mention who used the equation with Pr ratio correction in STPP work.
## talk about temperature range and Pr and Prwall range for this project
## includes property ratio ##
## need to determine wall temperature to use Pr_wall. Will it be outside the properties range???????
## used by Jianfeng due to large property variations of molten salt has viscosity
correction ###
## see Petukhov page 531 below equation 56 for change of constant n=0.14 to
n=0.11. ##
### how large are the temperature difference (and constant property assumption)
####
37
9. Things to Do
Things to do include:
1. Determine properties of HTF (Janz, use critical properties to determine mu in
BSL does it agree with Janz, other published data, see Apurbas references). Is
published data at 1 atm?
2. Determine range of operating parameters to be studied (Re, Pr, Twall, Tfluid, P,
velocity, tube diameter, tube metal, heat flux,)
3. Why do published studies stop at Re=50000?
4. Are properties a function of T only. How close to boiling point is the Twall?
How sensitive are the properties to temperature? Is constant properties assumption valid?
5. Review published Nu correlations for turbulent flow in a circular tube. Limitations on temperature differential, Re, etc.
sources.
6. Use previous project to determine typical wall and fluid temperatures?
7. Parametric study of velocity profile inside annular and circular sections. Variation with Pr, Re, Di/Do, etc. to come up with correlation for the maximum
velocity location.
8. COMSOL model?
9. Boundary layer description
38
10. Conclusion
Should different velocities be used at different molten salt velocities?
Use higher velocity at higher molten salt velocity in order to increase flux. Higher
velocities will
Or instead of controlling flux over panel (high flux at low molten salt temps and low
flux at high molten salt temps) use high flux everywhere but the velocity has to increase
as the molten salt temperature increases. 10 tubes in parallel, then 8 tubes in parallel,
forming a single panel with constant heat flux over it?
39
11.References
ASME. 2010 (2011 addenda). ASME Boiler and Pressure Vessel Code, II, Part D,
Properties (metric): Materials. New York: ASME.
Avila-Marin, A. L., J. Fernandez-Reche, F. M. Tellez. 2013. Evaluation of the Potential of Central Receiver Solar Power Plants: Configuration, Optimization and
Trends. In Applied Energy, Volume 112, Pages 274-288.
Bhatti, M. S., R. K. Shah. 1987. Turbulent and Transition Flow Convective Heat
Transfer in Ducts. In Handbook of Single-Phase Convective Heat Transfer, edited by
S. Kakac, R. K. Shah, W. Aung. New York: John Wiley & Sons.
Bin, L., W. Yu-ting, M. Chong-fang, Y. Meng, G. Hang. 2009. Turbulent Convective Heat Transfer with Molten Salt in a Circular Pipe.
In International
Accessed 11 September.
www.eng.auburn.edu/~dmckwski/mech7210/condbook.pdf
Medrano, M., A. Gil, I. Martorell, X. Potau, L. F. Cabeza. 2010. State of the Art
on High-Temperature Thermal Energy Storage for Power Generation. Part 2 Case
Studies. In Renewable and Sustainable Energy Reviews, Volume 14, Pages 56-72.
Mills, D. 2004. Advances in Solar Thermal Electricity Technology. In Solar
Energy, Volume 76, Pages 19-31.
Nellis, G., Klein, S. 2008. Heat Transfer. New York: Cambridge University Press.
Norris, R. H. 1970. Some Simple Approximate Heat-Transfer Correlations for
Turbulent Flow in Ducts with Rough Surfaces. In Augmentation of Convective Heat
and Mass Transfer, Edited by A. E. Bergles, R. L. Webb., The Winter Annual Meeting
of the American Society of Mechanical Engineers. New York: ASME.
Petukhov, B. S. 1970. Heat Transfer and Friction in Turbulent Pipe Flow with
Variable Physical Properties. In Advances in Heat Transfer, Volume 6. New York:
Academic Press.
Schlichting, H. 1987. Boundary Layer Theory. Seventh edition. Translated by J.
Kestin. New York: McGraw-Hill.
Siebert, O. W., K. M. Brooks, L. J. Craigie, F. G. Hodge, L. T. Hutton, T. M. Laronge, J. I. Munro, D. P. Pope. 2008. Materials of Construction. In Perrys Chemical
Engineers Handbook, Eighth edition. Edited by D. W. Green, R. H. Perry. New York:
McGraw-Hill.
41
Sieder, E. N., G. E. Tate. 1936. Heat Transfer and Pressure Drop of Liquids in
Tubes. In Industrial and Engineering Chemistry, December, Volume 28, Number 12,
Pages 1429-1435.
Sleicher, C. A., M. W. Rouse. 1975. A Convenient Correlation for Heat Transfer
to Constant and Variable Property Fluids in Turbulent Pipe Flow. In International
Journal of Heat and Mass Transfer, Volume 18, Pages 677-683.
Vant-Hull, L. L. 2002. The Role of Allowable Flux Density in the Design and
Operation of Molten-Salt Solar Central Receivers. In ASME Journal of Solar Energy
Engineering, May, Volume 124, Pages 165-169.
White, F. M. 2005. Viscous Fluid Flow. Third edition. New York: McGraw-Hill.
Winterton, R. H. S. 1998. Where did the Dittus and Boelter Equation Come
From? In International Journal of Heat and Mass Transfer, Volume 41, Numbers 4-5,
Pages 809-810.
Wu, Y-T, C. Chen, B. Liu, C-F. Ma. 2012. Investigation on Forced Convection
Heat Transfer of Molten Salts in Circular Tubes. In International Communications in
Heat and Mass Transfer, Volume 39, Pages 1550-1555.
Wyatt, S. J. 2012. Circumferential Temperature Variation in Superheater Tubes
with Mutual Irradiation as Applied to a Solar Receiver Steam Generator. Masters
Project, Rensselaer Polytechnic Institute.
Zavoico, A. B. 2001. Solar Power Tower Design Basis Document. Revision 0.
SAND2001-2100, San Francisco: Sandia National Laboratories.