Beruflich Dokumente
Kultur Dokumente
Component
Legend :
Abbrev.
BPL
D
SD
A
L
DLT
Description
Path Length
Depth
Surface Dist.
Amplitude
Length
Delta
Inspection
Target Enc. Rate
Voltage Phased Ar.
Probe 1 [Freq, Model]
Wedge 1 [Velo, Model]
*[Smoothing, Sub-Sampling]
File Vers.
8
Info
Mid
50 V
5.00 MHz, X3-PE-5.0M64E0.6P
2.337 mm/s, X3-SB57-N55S
Operator
Procedure Ref
Encoder Info
Encoding Setup
Enc. Name
Scan Enc Resol.
Part
Material
Velocity [LW/SW]
Part Geometry
Thickness
Weld
Scan S1 - Sectorial PE
Signal Processing*
Digital Filter
Gain , Ref
Focal [Type, Dist]
Start/Stop Path
Start/Stop Angle
Acq. Freq.
Inspection Date
2016-04-05 16:35
Value
None, 1:8
Auto: 5.0 MHz
10.0 dB, 10.0 dB
Constant Depth, 30.00 mm
0.00 mm, 100.00 mm
48.00, 62.00
100 MHz
Page 1
Value
None, 1:16
Auto: 5.0 MHz
10.0 dB, 10.0 dB
Constant Depth, 30.00 mm
0.00 mm, 100.00 mm
45.00, 70.00
100 MHz
Value
None, 1:16
Auto: 5.0 MHz
10.0 dB, 10.0 dB
30.00 mm
No
0.00 mm, 75.00 mm
65.00, 16
100 MHz
Value
None, 1:16
Auto: 5.0 MHz
10.0 dB, 10.0 dB
30.00 mm
No
0.00 mm, 75.00 mm
45.00, 16
100 MHz
Value
None, 1:32
Auto: 5.0 MHz
10.0 dB, 10.0 dB
30.00 mm
No
0.00 mm, 50.00 mm
0.00, 16
50 MHz
Page 2
Probe Qty
Scan Qty
Voltage Phased Ar.
Target Enc. Rate
Material
Component
Serial #
Location Ref
Part Geometry
Thickness
Velocity LW
Probe Type
Manufacturer
Model #
Serial #
Frequency
Type
Manufacturer
Model #
Serial #
Contact Surface
1
5
50 V
Mid
Steel
N/A
N/A
N/A
Plate
25.00 mm
5.890 mm/s
Phased-Array 1D
Sonatest
X3-PE-5.0M64E0.6P
N/A
5.00 MHz
Angular
Sonatest
X3-SB57-N55S
N/A
Planar
Inspection
Alarms
Off
Encoded Axis Ref.
Part Reference
Job/Customer
N/A
Site
N/A
Part
Velocity SW
Cal. Block Serial #
Velocity SW
Weld
Weld Root Gap
Weld Top Bevel Width
Weld Face Left
3.240 mm/s
N/A
3.240 mm/s
Double V
2.00 mm
12.00 mm
0.86 mm
Probe P1 - Phased-Array 1D
Pulse Type
Square-Wave
Pulse Width
100.00 ns
First Elmt Pin #
1
Nb Elmt Dim 1
64
Elmt Pitch Dim 1
0.60 mm
Wedge P1 - Phased-Array 1D
Back Height
11.67 mm
Front Height
38.72 mm
Width
25.00 mm
Length
66.35 mm
Cut Angle
36.00
Operator
Qualification
Procedure Ref
Couplant
Roof Angle
Probe Back Dist
Probe Side Dist
Probe Inset
Wedge Velocity LW
N/A
N/A
N/A
N/A
6.00 mm
22.50
12.07 mm
6.00 mm
22.50
12.07 mm
0.50 mm
3.35 mm
10.00 mm
6.50 mm
Bottom Left Row
0.00
0.00 mm
1.00 mm
0.00 mm
2.337 mm/s
Page 3
Sectorial PE
10.0 dB, 10.0 dB
1.00
48.00
62.00
0.00 mm
100.00 mm
100.00 mm
0.00 s
SW 3.240 mm/s
Half Path
Scan S1 - Sectorial PE
Focal Mode
Constant Depth
Focal Dist
30.00 mm
Signal Rectification
Full
Digital Filter
Auto: 5.0 MHz
Sub-Sampling
1:8
Rejection
Disabled
Smoothing
None
Contouring
No
Probe TX/RX
P1 - Phased-Array 1D
Probe RX
P1 - Phased-Array 1D
First Elmt TX
1
Last Elmt TX
First Elmt RX
Last Elmt RX
Beam Qty.
Sample Qty.
Path Res.
Acq. Freq.
Velocity Cal Status
Wedge Delay Cal Status
Sensitivity Cal Status
Amp Tolerance
16
1
16
15
772
7.7 spl/mm
100 MHz
None
None
None
5.00%
Type
Gain , Ref
Resolution
Start Angle
Stop Angle
Start Path
Range Path
Stop Path
Zero
Wave Mode
Travel Mode
Sectorial PE
10.0 dB, 10.0 dB
1.00
45.00
70.00
0.00 mm
100.00 mm
100.00 mm
0.00 s
SW 3.240 mm/s
Half Path
Scan S2 - Sectorial PE
Focal Mode
Constant Depth
Focal Dist
30.00 mm
Signal Rectification
Full
Digital Filter
Auto: 5.0 MHz
Sub-Sampling
1:16
Rejection
Disabled
Smoothing
None
Contouring
No
Probe TX/RX
P1 - Phased-Array 1D
Probe RX
P1 - Phased-Array 1D
First Elmt TX
40
Last Elmt TX
First Elmt RX
Last Elmt RX
Beam Qty.
Sample Qty.
Path Res.
Acq. Freq.
Velocity Cal Status
Wedge Delay Cal Status
Sensitivity Cal Status
Amp Tolerance
55
40
55
26
388
3.9 spl/mm
100 MHz
None
None
None
5.00%
Type
Gain , Ref
Angle
Start Path
Range Path
Stop Path
Zero
Wave Mode
Travel Mode
Nb Active Elmt
Double Res
Linear PE
10.0 dB, 10.0 dB
65.00
0.00 mm
75.00 mm
75.00 mm
0.00 s
SW 3.240 mm/s
Half Path
16
No
Scan S3 - Linear PE
Focal Dist
30.00 mm
Signal Rectification
Full
Digital Filter
Auto: 5.0 MHz
Sub-Sampling
1:16
Rejection
Disabled
Smoothing
None
Contouring
No
IFT Active
No
Probe TX/RX
P1 - Phased-Array 1D
Probe RX
P1 - Phased-Array 1D
First Elmt TX
8
Last Elmt TX
First Elmt RX
Last Elmt RX
Beam Qty.
Sample Qty.
Path Res.
Acq. Freq.
Velocity Cal Status
Wedge Delay Cal Status
Sensitivity Cal Status
Amp Tolerance
64
8
64
42
292
3.9 spl/mm
100 MHz
None
None
None
5.00%
Type
Gain , Ref
Angle
Start Path
Range Path
Stop Path
Zero
Wave Mode
Travel Mode
Nb Active Elmt
Double Res
Linear PE
10.0 dB, 10.0 dB
45.00
0.00 mm
75.00 mm
75.00 mm
0.00 s
SW 3.240 mm/s
Half Path
16
No
Scan S4 - Linear PE
Focal Dist
30.00 mm
Signal Rectification
Full
Digital Filter
Auto: 5.0 MHz
Sub-Sampling
1:16
Rejection
Disabled
Smoothing
None
Contouring
No
IFT Active
No
Probe TX/RX
P1 - Phased-Array 1D
Probe RX
P1 - Phased-Array 1D
First Elmt TX
20
Last Elmt TX
First Elmt RX
Last Elmt RX
Beam Qty.
Sample Qty.
Path Res.
Acq. Freq.
Velocity Cal Status
Wedge Delay Cal Status
Sensitivity Cal Status
Amp Tolerance
64
20
64
30
292
3.9 spl/mm
100 MHz
None
None
None
5.00%
Page 4
W1 Index Off.
W1 Scan Off.
Encoding Setup
Enc. Name
Scan Axis Name
Scan Enc Type
Linear PE
10.0 dB, 10.0 dB
0.00
0.00 mm
50.00 mm
50.00 mm
0.00 s
LW 5.890 mm/s
Half Path
16
No
-20.00 mm
0.00 mm
Scan S5 - Linear PE
Focal Dist
30.00 mm
Signal Rectification
Full
Digital Filter
Auto: 5.0 MHz
Sub-Sampling
1:32
Rejection
Disabled
Smoothing
None
Contouring
No
IFT Active
No
Probe TX/RX
P1 - Phased-Array 1D
Probe RX
P1 - Phased-Array 1D
First Elmt TX
1
Geometry
W1 Rotation
Encoder Area CL Pos
90.0
0.00 mm
Encoder parameters
Scan Enc Resol.
32.0000 ticks/mm
Scan Start Pos
0.00 mm
Scan Distance
100.00 mm
Scan Stop Pos
100.00 mm
Last Elmt TX
First Elmt RX
Last Elmt RX
Beam Qty.
Sample Qty.
Path Res.
Acq. Freq.
Velocity Cal Status
Wedge Delay Cal Status
Sensitivity Cal Status
Amp Tolerance
Scan Step
Scan Invert Dir
Data File Size
Max Phys. Enc. Speed
64
1
64
49
28
0.6 spl/mm
50 MHz
None
None
None
5.00%
0.00 mm
0.00
1.00 mm
No
8.86 MB
37.0 mm/s
Page 5 (End)