Beruflich Dokumente
Kultur Dokumente
DESCRIPTION
Analogue transmitter for the continuous monitoring of gases
and vapours in the ambient air. Used in garages, chiller
rooms and heating systems, the -Gard MA series analogue
transmitter is a reliable gas detector.
APPLICATION
For the detection of gases within a wide range of commercial
applications. Due to the 4 20 mA analogue signal the
transmitter is compatible with most controllers & BMS
systems.
FEATURES
Continuous monitoring
Easy maintenance / calibration
Reverse polarity protected
Overload and short-circuit protected
Long life sensor
Low zero point drift
Poisoning stable
4 20 mA analogue signal output
Approved according to EN 61010-1; ANSI/UL 61010 1;
CAN/CSA-C22.2 No. 61010-1
CONNECTING DIAGRAM
www.msr-electronic.de
1 June 13
Specification subject to change without notice
Gard is a registered trademark of MSR electronic
SPECIFICATIONS
MA-0
CO
Sensor element
Response time
t90 (s)
Stability & resolution
Repeatability (% of reading)
Long term zero point drift
of reading/ year
Long term sensitivity drift
(% reading/month)
Sensor life expectancy
(normal operating
environment) in years
Max. storage time
Operating Environment
Humidity non-condensing
Physical characteristics
Enclosure type A
Flammability
Enclosure color
Dimensions
Weight
Protection class
Installation
Cable entry
Wire connection
Wire distance
Output signal
Analogue output signal
Standard: 4-20 mA
MA-9
NO
MA-2
NO2
MA-5
SO2
MA-2
NH3
Electrochemical, diffusion
50
15
45
25
15
120
3
ppm
3%
0.1
vol. %
---
0.2
ppm
---
0.2
ppm
2%
0.2
ppm
2%
< 20
ppm
---
< 5%
--< 4%
/12
2
< 0,2
ppm
< 2%
/1
2
< 0,2
ppm
< 2%
/1
2
---
---
< 0,3
ppm
< 5%
/12
2
< 2%
/1
2
MA-2
Ex
MA-2
NH3
MA-3
NH3
Catalytic bead
(Pellistor)
10
(Methane)
1% of
reading
-- < 6% LEL
(Methane)
< 1,5%
Methane
3
-30 to
+ 50C
5 C to + 40 C
Atmospheric 10%
100
50
50
---
---
---
---
---
---
---
---
---
---
---
---
---
---
15 90 % RH
15 95 % RH
-15 to + 50C
-15 to + 50 C
0 to + 50 C
0 to + 50 C
Polycarbonate
UL 94: V2
RAL 7032 (light grey)
(W x D x H) 94 x 130 x 57 mm
Approx. 0.3 kg
IP 65
Wall or pillar mounting
Standard 1 x M20
2
2
Screw type terminal, min. 0.25 mm (24 AWG) max. 2.5 mm (14 AWG)
Max. loop resist. 500 (= wire resistor + controller input resistor)
Proportional, 4 20 mA, load 500 overload and short-circuit proof
Warranty
www.msr-electronic.de
MA-3
ETO
30
Meth.
---
Guidelines
MA-4
Ex
12 months
15 90 % RH
-10 to + 50C
MA-4
Freon
Semiconductor sensor
6 months
Temperature
Working temperature
Storage temperature
Pressure range
Electrical
Power supply
Power consumption
MA-9
O2
2 June 13
Specification subject to change without notice
Gard is a registered trademark of MSR electronic
---
ORDERING
INFORMATION
MA-X-XXXXFX
4
6
7
8
9
A
B
C
D
E
F
K
L
M
Q
F
F1
A
D
D1
5
1
Version
5, 6
Factory calibration 0 20 ppm
1, 5, 8
Factory calibration 0 50 ppm
1
Factory calibration 0 100 ppm
1
Factory calibration 0 150 ppm
1
Factory calibration 0 200 ppm
1
Factory calibration 0 250 ppm
1, 2, 19 to 24
Factory calibration 0 300 ppm
1
Factory calibration 0 400 ppm
1
Factory calibration 0 500 ppm
1, 2
Factory calibration 0 1000 ppm
12 to 25, 34
Factory calibration 20 2000 ppm
7
Factory calibration 0 25 vol %
36
Factory calibration 0 50% LEL
3, 30, 31, 35
Factory calibration 0 100 % LEL
4
Factory calibration 30 300 ppm
Enclosure
Plastic enclosure (87 x 45.5 mm) IP43
Plastic enclosure (87 x 45,5 mm) IP44
Plastic enclosure (130 x 94 x 57 mm) IP65
Plastic enclosure (65 x 94 x 57 mm) IP43
Plastic enclosure (65 x 94 x 57 mm) IP54
Stainless steel enclosure
0-1110
2
5-1120
3
2-1120
4
3-1120
5
9-1129
6
2-1130
7
9-1195
8
5-1196
12
4-2070
13
4-2071
14
4-2072
15
4-2073
16
4-2074
17
4-2075
18
4-2076
19
4-2077
20
4-2078
21
4-2079
22
4-2069
23
4-2068
24
4-2067
25
4-2064
30
2-3400
31
2-3480
36
4-3H55
35
4-3H80
34
3-2089
Gas*
Carbon monoxide CO
Ammonia
NH3 El.Chem.
Ammonia
NH3 Pellistor
Ammonia
NH3 Semiconductor sensor
Nitrogen monoxide NO
Nitrogen dioxide NO2
Oxygen
O2
Sulphur dioxide
SO2
Freon
R 22
Freon
R 401a
Freon
R 401b
Freon
R 402a
Freon
R 402b
Freon
R 408a
Freon
R 409a
Freon
R 134a
Freon
R 404a
Freon
R 416a
Freon
R 507
Freon
R 410a
Freon
R 411a
Freon
R 123
Methane
CH4
Propane
C3H8
Methane
CH4 (Semiconductor sensor)
Propane/ LPG
C3H8 (Semiconductor sensor)
Ethylene
C2H4 (Semiconductor sensor)
* The sensors partially have a cross-sensitivity to other gases due to the measuring principle. More information on request.
Example: Freon Transmitter for R 134 a, plastic enclosure, factory calibration 20 2000 ppm
Order number: MA-4-2077-F-F
www.msr-electronic.de
3 June 13
Specification subject to change without notice
Gard is a registered trademark of MSR electronic