Beruflich Dokumente
Kultur Dokumente
I. MULLION DEFLECTION
1. LIGHT MULLION (FLAT WALL)
a. STRUCTURAL TEST
PRESSURE (Pa)
1,750
0
3,500
0
-2,000
0
-4,000
0
DEFLECTION (mm)
2.635
-0.025
5.410
0.100
-3.025
-0.105
-6.360
-0.110
b. SAFETY TEST
PRESSURE (Pa)
2,625
0
5,250
0
-3,000
0
-6,000
0
DEFLECTION CHECK
ALLOWABLE DEFLECTION AT 100% LOAD:
MAXIMUM ACTUAL DEFLECTION:
ASSESSMENT:
DEFLECTION (mm)
3.625
-0.030
7.185
-0.075
-4.730
-0.050
-9.530
-0.085
DEFLECTION (mm)
2.455
0.020
4.960
0.175
-3.180
-0.095
-6.570
0.085
b. SAFETY TEST
PRESSURE (Pa)
2,625
0
5,250
0
-3,375
0
-6,750
0
DEFLECTION CHECK
ALLOWABLE DEFLECTION AT 100% LOAD:
MAXIMUM ACTUAL DEFLECTION:
ASSESSMENT:
DEFLECTION (mm)
3.755
0.040
7.105
0.020
-5.195
-0.060
-10.000
-0.120
DEFLECTION (mm)
0.895
-0.045
2.048
0.045
-1.080
0.055
-2.520
0.060
b. SAFETY TEST
PRESSURE (Pa)
2,625
0
5,250
0
-3,375
0
-6,750
0
DEFLECTION CHECK
ALLOWABLE DEFLECTION AT 100% LOAD:
MAXIMUM ACTUAL DEFLECTION:
ASSESSMENT:
DEFLECTION (mm)
1.160
-0.345
3.065
0.225
-2.220
-0.150
-4.055
-0.065
4. CORNER MULLION
a. STRUCTURAL TEST
PRESSURE (Pa)
1,750
0
3,500
0
-2,250
0
-4,500
0
DEFLECTION (mm)
0.470
-0.005
1.145
0.040
-0.605
0.030
-1.470
0.005
b. SAFETY TEST
PRESSURE (Pa)
2,625
0
5,250
0
-3,375
0
-6,750
0
DEFLECTION CHECK
ALLOWABLE DEFLECTION AT 100% LOAD:
MAXIMUM ACTUAL DEFLECTION:
ASSESSMENT:
DEFLECTION (mm)
0.890
0.005
2.400
0.200
-0.955
0.015
-1.970
0.010
5. STACKJOINT TRANSOM
a. STRUCTURAL TEST
PRESSURE (Pa)
1,750
0
3,500
0
-2,250
0
-4,500
0
DEFLECTION (mm)
0.025
0.005
-0.030
-0.010
-0.030
0.060
-0.285
-0.085
b. SAFETY TEST
PRESSURE (Pa)
2,625
0
5,250
0
-3,375
0
-6,750
0
DEFLECTION CHECK
ALLOWABLE DEFLECTION AT 100% LOAD:
MAXIMUM ACTUAL DEFLECTION:
ASSESSMENT:
DEFLECTION (mm)
0.090
-0.015
0.310
0.030
0.010
-0.025
-0.850
0.060
6. INTERMEDIATE TRANSOM
a. STRUCTURAL TEST
PRESSURE (Pa)
1,750
0
3,500
0
-2,250
0
-4,500
0
DEFLECTION (mm)
-0.100
0.130
-0.230
0.080
0.090
0.040
0.110
0.000
b. SAFETY TEST
PRESSURE (Pa)
2,625
0
5,250
0
-3,375
0
-6,750
0
DEFLECTION CHECK
ALLOWABLE DEFLECTION AT 100% LOAD:
MAXIMUM ACTUAL DEFLECTION:
ASSESSMENT:
DEFLECTION (mm)
-0.540
0.025
-0.935
0.005
0.525
0.030
0.500
0.015
7. IGU PANEL
a. STRUCTURAL TEST
PRESSURE (Pa)
1,750
0
3,500
0
-2,250
0
-4,500
0
DEFLECTION (mm)
4.140
-0.130
8.180
0.205
-5.595
-0.080
-10.375
0.015
b. SAFETY TEST
PRESSURE (Pa)
2,625
0
5,250
0
-3,375
0
-6,750
0
DEFLECTION CHECK
ALLOWABLE DEFLECTION AT 100% LOAD:
MAXIMUM ACTUAL DEFLECTION:
ASSESSMENT:
DEFLECTION (mm)
6.315
0.060
11.320
0.050
-7.930
0.025
-14.450
-0.165
b/60
1360mm/60 = 22.67mm
PASS