Beruflich Dokumente
Kultur Dokumente
Analytical Technology
&
On-line Monitoring Solutions
Content
Chlorine
Brine quality
Explosion protection
Membrane permeation
Drying processes
QC/QA of chlorine
Mercury processes
Environmental compliance
AppliTek is committed
to promoting, advising
and commissioning
analysis solutions for
assessing and controlling
production processes as
well as processes related
to production, in order to
assure quality control, to
protect the environment
and to enhance safety.
Corporate Objective
EDC
Control of chlorination reactor
Control of oxychlorination reactor
Moisture in EDC purification
QC/QA of liquid EDC
EDC drying processes
Corrosion prevention
VC
QC/QA of liquid VC
Corrosion prevention
Explosion protection
PVC
Chlorine
Ethylene Dichloride
Vinyl Chloride
Page 5
Page 17
VC Production Process
Page 20
Ch lo ri n e In d us tr y
For more than 10 years, AppliTek on-line analyzer systems have been guaranteeing safety, production
efficiency and trouble-free operation In the chlor-alkali industry. AppliTek is your manufacturer of
dedicated analytics and one-stop-shop for highly advanced answers to the industrys needs,
implemented in all steps of the chlorine production process:
Start-up / Commissioning
As a single source supplier, AppliTek takes care of the commissioning of the
complete analyzer project, including start-up together with plant management
and operators. Local partners complement our service package, and can assist
you quickly in case of trouble shooting.
Process Overview
A p p l i Te k A n a l y t i c a l S o l u t i o n s f o r t h e C h l o r i n e P r o d u c t i o n P r o c e s s
Monitoring and controlling highly delicate production
processes is an equally delicate task, preserved for
specialists having extensive experience in the design,
manufacturing as well as commissioning of key analytics.
The AppliTek analyzer systems implemented in chloralkali processes are especially designed and field-tested
for more than 10 years for your peace of mind.
Technical proposals involve all the necessary
requirements to guarantee a proper functionality of the
on-line analyzer systems in order to monitor the safety
and control of the processes. Low maintenance and long
life-time is guaranteed by the specific design and the
choice of components, as well as the use of special
preconditioning systems.
Chlorine Electrolysis
Typical range:
on analyzer display 0 4% HCl 0 - 2% H2 by UV reactor (Cl2 + H2 --> 2HCl)(1)
on analyzer display 0 4% HCl 0 - 2% H2 by UV reactor (Cl2 + H2 --> 2HCl) (1)
on analyzer display 0 2% HCl 0 - 1% H2 by UV reactor (Cl2 + H2 --> 2HCl) (1)
Brine Recovery
(1)
Bleach Production
A p p l i Te k A n a l y t i c a l S o l u t i o n s f o r t h e C h l o r i n e P r o d u c t i o n P r o c e s s
Description
Description: absorption of chlorine (Cl2 ) in sodium hydroxide (NaOH) for chlorine destruction and production of sodium
hypochlorite or bleach (NaOCl)
2 NaOH + Cl2 NaOCl + NaCl + H2 O
In case of excess sodium hydroxide consumption the sodium hypochlorite (NaOCl) will be decomposed:
@pH 8
NaOCl NaCl + O2
@pH 9 10
EZ-BLEACH onon - line analyzer system for the determination of sodium hypochlorite (NaOCl), sodium carbonate (Na 2 CO 3 ),
sodium hydroxide (NaOH) and sodium chloride (NaCl) in sodium hypochlorite (NaOCl)
Monitor reactor sodium hydroxide (NaOH) concentration:
1 30g/kg NaCl
A p p l i Te k A n a l y t i c a l S o l u t i o n s f o r t h e C h l o r i n e P r o d u c t i o n P r o c e s s
Mercury facilities
Older production facilities such as mercury type plants can also
benefit from AppliTek engineered solutions. Environmental
compliance for emissions is a growing concern, both in waste
water and in ambient air. On-line monitoring of Mercury not only
enables you to detect calamities and take the necessary actions,
but also to improve the physico-chemical water treatment and
security of the working environment.
Et h y l en e Di c hl or i de I n du st r y
As a specialist manufacturer of analytics, AppliTek is your one-stop-shop for highly advanced answers
to the specific needs of the chemical industry. Ethylene dichloride (EDC) is a chemical liquid that is
not found naturally in the environment, and classified as a hazardous chemical. Process control, as
implemented by AppliTek, will significantly increase output, product quality, and decrease production
hazards. Environmental compliance is another value-added benefit of the AppliTek technology.
AppliTek supplies solutions to all the types of EDC production:
Chlorination process
Oxychlorination process
Start-up / Commissioning
As a single source supplier, AppliTek takes care of the commissioning of the
complete analyzer project. Protective corrosion resistant shelters will be
delivered to your site, prefabricated and equipped with all necessary equipment,
systems and utilities to start the monitoring tasks.
QC / QA
AppliTek also takes care of process quality control. Ethylene dichloride is
typically used for the production of of vinyl chloride. Liquid EDC is also used
as a commercial available product and transported by ship. All commercially
available EDC must be free of Hydrogen Chloride to prevent corrosion of the
storage and handling equipment.
Process Overview
A p p l i Te k A n a l y t i c a l S o l u t i o n s f o r t h e E D C P r o d u c t i o n P r o c e s s
Ty p e : E D C b y c h l o r i n a t i o n
3
5
6
7
8
8
6
7
Chlorination process
Oxygen in Vent Gas CHLORINATION reactor
Keep your oxygen levels outside flammable limits
Control of Oxygen (O2 ) content in recycled gases & adjustment of O2 / C 2 H4 ratio in CHLORINATION reactor. On-line analyzer system uses Selective Oxygen (O2 ) measurement by Paramagnetic analyzer (fast response) with corrosive resistant
measuring chamber.
Typical range: 015%vol O2 (1)
Ethylene (C 2 H 4 ) in Vent Gas CHLORINATION reactor
Minimize Ethylene (C 2 H4 ) losses by feedback control of C 2 H4 / Cl2 ratio
Control of Ethylene (C 2 H4 ) content in recycled gases & adjustment of Cl2 / C 2 H4 ratio in CHLORINATION reactor. On-line
analyzer system uses Selective Ethylene (C 2 H4 ) measurement by Multi-Wavelength INFRARED analyzer with automatic
optical span possibility.
Typical range: 030%vol C 2 H4 (1)
Residual Chlorine in liquid phase EDC Ethylene Dichloride (C 2 H 4 Cl 2 )
Avoid risk of corrosion & severe damage to your installation
On-line analyzer system uses a scrubber system where nitrogen flow is bubbling through the liquid Ethylene Dichloride (EDC). The resulting vapor phase will contain mainly N2 , the stripped Chlorine (Cl2 ) and saturated Ethylene
Dichloride (EDC). A thermostatically controlled electrical cooler removes most of the Ethylene Dichloride (EDC),
and the remaining Chlorine (Cl2 ) is analyzed by the Multi-wavelength UV analyzer.
Typical range: 0 3,000 ppm Cl2 (1)
Ferric Chloride (FeCl 3 ) in liquid phase EDC Ethylene Dichloride (C 2 H 4 Cl 2 )
Avoid contamination of EDC and risk of corrosion damaging your installation
Ferric Chloride (FeCl3 ) is used as catalyst in the EDC reactor. The FeCl3 colors the EDC with a yellow / brown color
which is measured with an OPACIMETER.
Typical range: 0 300 ppm FeCl3 (1)
Quality (purity) of liquid phase EDC Ethylene Dichloride (C 2 H4 Cl 2 )
Avoid contamination of EDC and off spec product
On-line analyzer system uses Gas-chromatography
Ethylchloride - VC- CCl4 - C3 - C4 - Chloroform - CHCl3
Typical range: 0 5000 ppm (1)
Hydrogen Chloride in liquid phase EDC Ethylene Dichloride (C 2 H 4 Cl 2 )
Protect your EDC storage or transport against corrosion by HCl
All commercial available EDC must be free of Hydrogen Chloride (HCl) to prevent corrosion of the storage and handling equipment. For this reason it is advisable to monitor downstream of the purification column on-line the Hydrogen Chloride (HCl) concentration in Ethylene dichloride EDC (C 2H4 Cl2 ) by Ionic detection using Conductivity
Typical range: 0 10 ppm HCl (1)
Water in recycled EDC Ethylene Dichloride (C
(C 2 H 4 Cl 2 ) - feed Chlorination unit
Water in EDC Ethylene Dichloride (C 2H4 Cl2 ) - (EDC purification unit) top Light Column
Water in EDC Ethylene Dichloride (C 2H4 Cl2 ) - (EDC purification unit) top Heavies Column
Avoid risk of corrosion & severe damages
by on-line selective measurement of moisture (H2 O) in liquid phase EDC using Multi-Wavelength INFRARED
Typical range: 0 50 ppm H2 O (1)
| APPLITEK On-line Monitoring Solutions for the Chlor-alkali Industry | 14
Process Overview
A p p l i Te k A n a l y t i c a l S o l u t i o n s f o r t h e E D C P r o d u c t i o n P r o c e s s
Ty p e : E D C b y o x y c h l o r i n a t i o n
5
7
8
Oxychlorination process
Oxygen in Vent Gas OXYCHLORINATION reactor
Keep your oxygen levels outside flammable limits
Control of Oxygen (O2 ) content in recycled gases & adjustment of O2 / C 2 H4 ratio in OXYCHLORINATION reactor. On-line
analyzer system uses Selective Oxygen (O2 ) measurement by Paramagnetic analyzer (fast response) with corrosive resistant measuring chamber.
Typical range: 05%vol O2 (1)
CO & CO 2 in Vent Gas in Vent Gas OXYCHLORINATION reactor
Optimize your process by optimizing the CO/ CO2 content
Control of CO/CO2 content in recycled gasses & adjustment of CO / CO2 ratio in OXYCHLORINATION reactor. On-line
analyzer system uses Selective CO/ CO2 measurement by Multi-Wavelenght INFRARED analyzer with automatic optical
span possibility.
Typical range: 010%vol CO / 050%vol CO2 (1)
Ethylene (C 2 H 4 ) in Vent Gas OXYCHLORINATION reactor
Control C 2 H4 content in recycled gas & adjustment of O2 /C 2 H4 ratio
Control of Ethylene (C 2 H4 ) content in recycled gases & adjustment of O2 /C 2H4 ratio in OXYCHLORINATION reactor. Online analyzer system uses Selective Ethylene (C 2 H4 ) measurement by Multi-Wavelength INFRARED analyzer with automatic optical span possibility.
Typical range: 010%vol C 2 H4 (1)
Chlorinated Organics in Water
Avoid contamination to protect environment.. On-line analyzer system uses a scrubber system where a carrier flow is
bubbling through the water. The vapor phase is measured by a Flame Ionization Detector (FID) and is a measure for
the Chlorinated Organics of the water.
Typical range: 0 15 mg/l CO units (1)
Water in liquid EDC Ethylene Dichloride (C 2 H 4 Cl 2 ) - from Drying Column
Avoid risk of corrosion & severe damages
by on-line selective measurement of moisture (H2 O) in liquid phase EDC using Multi-Wavelength INFRARED
Typical range: 0 50 ppm H2 O (1)
Hydrogen Chloride in liquid phase EDC Ethylene Dichloride (C 2 H 4 Cl 2 )
Protect your EDC storage or transport against corrosion by HCl
All commercial available EDC must be free of Hydrogen Chloride (HCl) to prevent corrosion of the storage and
handling equipment. For this reason it is advisable to monitor downstream of the purification column on-line the
Hydrogen Chloride (HCl) concentration in Ethylene dichloride EDC (C 2 H4Cl2 ) by Ionic detection using Conductivity
Typical range: 0 10 ppm HCl (1)
Composition vent gas OXYCHLORINATION by Gas Chromatograph
Typical range: 0 100%vol N2 0 20%vol CO 0 50%vol CO2 0 20%vol 1.2-EDC 0 5%vol Ethane
0 10%vol Ethylene 0 1%vol Methane 0 10%vol O2 0 5%vol H2
Vi n y l C hl or id e I n du st r y
Ethylene dichloride (EDC) serves as the primary feedstock for the vinyl chloride (VC/VCM) industry.
The EDC from the storage tank is cracked in the cracking furnace, resulting in the production of
vinyl chloride monomer, hydrogen chloride and other by-products. At this stage of he EDC-VC
chain, process monitoring is absolutely necessary to maintain control over the corrosive, hazardous
nature of the product, while achieving maximum output efficiency at this level AppliTek is also
your partner for critical parameter monitoring.
Portfolio of solutions
Worldwide AppliTek has installed numerous analyzer systems for the chemical
and petrochemical industry. Most of our analytical solutions are field-proven and
recommended by industry specialists and industry associations. For the VC
industry, AppliTek provides solutions to increase lifetime and safety of the
production environment, and to increase QC/QA.
Impurities monitoring
Compliance with product specs is necessary to commercial ends. Knowing trace
impurities in polymer grade VCM is of utmost importance in the manufacturing
of PVC. Similar to the EDC production process, on-line gas chromatography is
used to monitor impurities in the VC end product (gas phase).
Process Overview
A p p l i Te k A n a l y t i c a l S o l u t i o n s f o r t h e V C P r o d u c t i o n P r o c e s s
1
2
UPA Acidity in VC
4
5
VC parameters - Overview
(1) Other ranges on request.
OnOn - line analyzer system for Acidity (HCl) in Vinyl Chloride (VC) 2(C 2 H 3 Cl)
Protect VC storage or transport against corrosion.
All commercial available VC must be free of Hydrogen Chloride (HCl) to prevent corrosion of the storage and handling
equipment. For this reason it is advisable to monitor on-line the Hydrogen Chloride (HCl) by means of UPA Universal
Process Analyzer technology.
Typical range: 0 100 ppm HCl
Impurities in gas phase VC
Typical range: 0 100 ppm methyl chloride 0 20 ppm butadiene 0 500 ppm vinylacetylene
0 100 ppm ethylchloride 0 20 ppm 1,1 EDC 0 100 ppm 1,2 EDC
Po l y Vi n y l C hl or i de I n du st r y
Polymer powders can be burned during the drying process causing black, brown, pink or yellow
powder particles (called specks) in the finished product. The AppliTek EZ-PowderScan is an
on-line quality control system based on optical scanning, designed to be implemented as a
powerful QC/QA tool in the polymerization stage.
Process Overview
A p p l i Te k A n a l y t i c a l S o l u t i o n s f o r t h e P V C P r o d u c t i o n P r o c e s s
Chlorine Production
Step 2:
Ethylene Production
Step 3:
Step 4:
The basic fine white PVC powder, produced by polymerization is then mixed with one or more additives. There are two
main types: 'stabilizers', which allow the PVC to be processed without degradation during moulding or extrusion, and
'plasticizers', which give it flexibility. Additives can also give PVC great strength, make it colored or confer whichever
qualities are desired in the end product. Finally, the PVC granules or ready-to-use powders, are converted into final products
via numerous specific techniques.
After polymerization reaction the PVC powder is dried. During the drying process the PVC powder can be burned causing
black or brown spots in the end product. (defined as BB100). The produced PVC powder must have a minimum quality
(maximum amount of black or brown spots). This is exactly what the EZ-PowderScan monitors, on a 24/7 basis.
Benefits
High reliability
Low maintenance
NO restriction in process line
NO pollution of PVC powder
Manipulation EZ - PowderScan possible without process stop (PVC
process usually never stops)
EZEZ - PowderScan is a real on-line measurement
BB100 Result every 5 minutes
Guarantees PVC powder quality
Reduce give-away
EZEZ - PowderScan is flexible in use (any PVC type)
Contaminant color can be free defined
Preventing 1 contamination incident is enough to fund for the EZEZ PowderScan on-line analyzer system
Fast measurement, very limited PVC powder waste
Single
Source
Responsibility
Program
So lu ti o ns a n d S e r v ic es
AppliTek supplies you with the ideal formula for all your needs in process control/monitoring.
From the feasibility to the basic engineering until the implementation of the analyzer system,
AppliTek is and remains your single partner. The Single Source Responsibility Program is the
AppliTek symbiosis between analytical expertise and system integration, finalized in-house until
the delivery to the plant. Service and maintenance complete our task as a single source supplier
and are carefully planned during the implementation of the system and the on-site training of
management and operators.
Application laboratory
Engineering
In-house CAD ExPert team
In-house Ex Proof (ATEX/NEC)
ExPert team
In-house Software/PLC expert team
In-house Preconditioning ExPert team
Cost planning
Basic & Detail engineering
ConstructionIntegration
Commissioning - Servicing
AppliTek
AppliTek NV/SA
B-9810 Nazareth
Belgium
E-mail: team@applitek.com
Alternatively: c.du.bois@applitek.com