HWP (M)

STANDARD OPERATING
PROCEDURE OF MULTI
PURPOSE TENDER

DOC. NO. FR/EQP/32/5

BASIS:

Suppliers Maintenance instructions, Fire Service Manual &


Work experience.

ITEM:

MULTI PURPOSE TENDER PUMP (s):


Hydrant

A. From Fire

(Tick () for O.K & (X) for not O.K)


Sl.No.
Items of Test
1
Park the vehicle on hard, level surface & near
to the hydrant
2
Apply hand brake
3
Apply 2nd. gear & engage P.T.O. lever
4
Ensure all doors of cabin are in closed
condition
5
Ensure all valves are in closed condition
6
Connect delivery hose line between hydrant &
suction inlet or hydrant to tank
7
Slightly open one delivery valve of pump to
release the air & close the same
8
Open cooling valve
9
Open the delivery valve(s) & accelerate
throttle as required
10
Use visual/whistle/line signals from starting to
completion of the work
11
After completion of the job, close all valves
except cooling valve
12
Normalize the accelerator
13
Close the cooling valve
14
Enter in cabin, disengage the PTO lever & 2nd.
gear
15
Check the air in air pressure gauge if required
to up
16
Check water level in water tank
17
Stop the engine

HWP (M)
BASIS:
ITEM:

STANDARD OPERATING
PROCEDURE
CONTD...

Results

Remarks

DOC. NO. FR/EQP/32/5

Suppliers Maintenance instructions, Fire Service Manual &


Work experience.
MULTI PURPOSE TENDER PUMP (s):
B. Open Water source.

(Tick () for O.K & (X) for not O.K)


Sl.No.
Items of Test
Results
1
Park the vehicle on hard, level surface & near
to water source
2
Apply hand brake
3
Connect suction hoses, metal strainer & basket
strainer. Apply clove hitch on basket strainer &
submerged well in the water.
4
Apply half hitch on suction (s) joints
5
Apply half hitches & thumb knot to a hard

18

object
Ensure all valves are in closed condition
Apply 2nd. gear & engage P.T.O. lever
Accelerate throttle as required. Watch the
compound gauge & pressure gauge. If pressure
gauge shown positive pressure, pump ready to
prime
Connect delivery hose(s) to delivery out let(s)
as required
Slightly open delivery valve but fully
Open cooling valve
As per the requirement of branch man
accelerate pressure by operating the throttle as
required
Use visual/whistle/line signals from starting to
completion of the work
After completion of job, close all valves
Normalize the accelerator
Close the cooling valve
Enter in cabin, disengage the PTO lever & 2nd.
gear
Check the air in air pressure gauge if required

19

to up
Stop the engine

6
7
8

9
10
11
12
13
14
15
16
17

HWP (M)

STANDARD OPERATING
PROCEDURE
CONTD...

Remarks

DOC. NO. FR/EQP/32/5

BASIS:

Suppliers Maintenance instructions, Fire Service Manual &


Work experience.

ITEM:

MULTI PURPOSE TENDER PUMP (s):

C. Hose Reel

There are three provisions in hose reel namely 1.Low pressure hose reel
2.Hydrant to hose reel and 3. High pressure hose Reel
1. Low pressure Hose Reel:-

(Tick () for O.K & (X) for not O.K)


Sl.No.
Items of Test
1
Engage the PTO lever
2
Take hose reel hose up to target point & put
nozzle valve in open condition
3
Give visual signal or whistle signal for water
ON as well as further requirement of pressure
4
Build up the pressure gradually but fully
according to branch man.
5
After completion of the job, reduce the throttle
& close valve of hose reel and pump to hose
reel
6
Ensure proper rolling the hose reel on hose
7

Results

Remarks

Results

Remarks

drum
Operate the flush valve.

2. Hydrant to hose reel:(Tick () for O.K & (X) for not O.K)
Sl.No.
Items of Test
1
Remove the blank cap on Auxiliary connection
2
Connect delivery hose between hydrant & hose
reel connection
3
Follow the point 01 to 07 as mentioned above.

HWP (M)

STANDARD OPERATING
PROCEDURE
CONTD...

DOC. NO. FR/EQP/32/5

BASIS:

Suppliers Maintenance instructions, Fire Service Manual &


Work experience.

ITEM:

MULTI PURPOSE TENDER PUMP (s):

D. Hose Reel

There are three provisions in hose reel namely 1.Low pressure hose reel
2.Hydrant to hose reel and 3. High pressure hose Reel
3. High pressure Hose Reel:(Tick () for O.K & (X) for not O.K)

Sl.No.
Items of Test
1
Engage the PTO lever
2
Take hose reel hose up to target point & put
nozzle valve in open condition
3.
Hold high pressure gun firmly
4.
Give visual signal or whistle signal for water
ON as well as further requirement of pressure
5.
Open out let valve
6.
Build up the pressure gradually but fully
according to branch man.
7.
Adjust high pressure gun lever to get spray/jet
8
After completion of the job, give signal to
reduce pressure
9
Ensure proper rolling the hose reel on hose
10

Results

Remarks

drum
Operate the flush valve.

HWP (M)

STANDARD OPERATING
PROCEDURE
CONTD...

DOC. NO. FR/EQP/32/5

BASIS:

Suppliers Maintenance instructions, Fire Service Manual &


Work experience.

ITEM:

MULTI PURPOSE TENDER PUMP (s):

E. Water Monitor

There are two provisions in monitor namely 1.Water monitor 2.Foam monitor and
3. Foam Provision on hand line (s).
1. Water Monitor:
1

It can be use, while using at open source water or with MPT water tank/hydrant
to tank but the procedure is same as explained in DOC. No.FR/EQP/32/13 & 14.
(Tick () for O.K & (X) for not O.K)
Sl.No.
Items of Test
1
Depute fireman on top of the MPT to operate
monitor

Results

Remarks

2
3
4
5
6
7
8
9

Aim it suitable direction


Give visual signal or whistle signal for water
ON as well as further requirement of pressure
Open pump to monitor valve
Build up the pressure gradually but fully
according to branch man.
Adjust the monitor to get spray/jet
After completion of the job, give signal to
reduce pressure
Ensure proper closing the above valve
Operate the flush valve.

HWP (M)

STANDARD OPERATING
PROCEDURE
CONTD...

DOC. NO. FR/EQP/32/19

BASIS:

Suppliers Maintenance instructions, Fire Service Manual &


Work experience.

ITEM:

MULTI PURPOSE TENDER PUMP (s):

F. Foam Monitor

There are two provisions in monitor namely 1.Water monitor 2.Foam monitor and
3. Foam Provision on hand line (s).
2. Foam Monitor:
1

It can be use, while using at open source water or with MPT water tank/hydrant
to tank but the procedure is same as explained in DOC. No.FR/EQP/32/13 & 14.
(Tick () for O.K & (X) for not O.K)
Sl.No.
Items of Test
1
Depute fireman on top of the MPT to operate
monitor
2
Aim it to suitable direction
3.
Give visual signal or whistle signal for water
ON as well as further requirement of pressure
4.
Open pump to monitor valve
5.
Build up the pressure gradually but fully

Results

Remarks

6.
7.
8.
9.
10

according to branch man but it shall not less


than 7kg/cm2
Adjust the monitor to get spray/jet
Select the Foam Proportionate valve as per
requirement and apply foam on fire
After completion of the job, give signal to
reduce pressure
Ensure proper closing the above valve
Operate the flush valve.

HWP (M)

STANDARD OPERATING
PROCEDURE
CONTD...

DOC. NO. FR/EQP/32/5

BASIS: Suppliers Maintenance instructions, Fire Service Manual & Work


experience.
ITEM

MULTI PURPOSE TENDER PUMP (s): G.Foam Provision on hand


line(s)

There are two provisions in monitor namely 1.Water monitor 2.Foam monitor and
3. Foam Provision on hand line (s).
3. Foam provision on hand line (s) :
1

It can be use, while using at open source water or with MPT water tank/hydrant
to tank but the procedure is same as explained in DOC. No.FR/EQP/32/13 & 14.
(Tick () for O.K & (X) for not O.K)
Sl.No.
1
2
3
4
5
6
7
8
9

Items of Test
Laid deliver hose line from pump to target point
Connect hose line (s) to pump delivery
Connect MFG- 5 at other hand with pickup tube
Submerge the pickup tube strainer pipe in to
foam solution container
Always keep handy two spare foam drums
Spray the water beside to target.
Gradually enhance the pressure up to 7 kg/cm 2
Ensure proper foam is producing
Than apply foam on target point

Results

Remarks

10
11
12
13
14
15

Give visual signal or whistle signal for water


ON as well as further requirement of pressure
After extinguishing the fire give proper signal for
knock off/make up
Normalize the throttle
Close delivery valve (s) & Cooling valve
Flush the MFG 5 with plenty of water
Operate the flush valve.

HWP (M)

STANDARD OPERATING
PROCEDURE
CONTD...

DOC. NO. FR/EQP/32/5

BASIS:

Suppliers Maintenance instructions, Fire Service Manual &


Work experience.

ITEM:

MULTI PURPOSE TENDER PUMP (s):

H. After Use.

(Tick () for O.K & (X) for not O.K)


Sl.No.
Items of Test
1
Water tank, radiator tank, fuel tank & Engine oil
shall be replenished
2
Drain the water from pump casing
3
Top up fresh water in priming box if required
4
Appliance, including the ancillary equipments
shall be thoroughly cleaned.
5
Apply grease to water pump, pump nipples &
U-J cross joints
6
Ensure proper fan belt tension
7
Check air pressure in all tyres
8
Check wheel nuts tighten as necessary
9
Check & ensure all stowed equipments
working condition
10
Clean all lockers & cabin
11
Open all locker for 30 minutes for free air
12
13
14

passage
Check all lights
Necessary entries shall be made in concern log
book
Park the MPT in proper turnout place & report it
is ready for turnout.

Results

Remarks

HWP (M)

STANDARD OPERATING
PROCEDURE
LIGHT MAST

DOC. NO. FR/EQP/32/6

BASIS:

Suppliers Maintenance instructions, Fire Service Manual &


Work experience.

ITEM:

MULTI PURPOSE TENDER.

Light Mast

Light Mast :
1

It can be used while fire fighting & rescue operations during night time where the
illumination is poor as explained in DOC. No.FR/EQP/32/13 & 14.
(Tick () for O.K & (X) for not O.K)
Sl.No.
Items of Test
1
Took the vehicle to out from garage. Start the
Engine & build up the air up to 6 kg/cm2 in
tank & ensure that drain valve of light Robot
shall be in open condition
2
Open the air tank valve. When air is passing
close the drain valve
3
Put on the switch near Emergency Stop button
& find the light must glow on cable remote
control
4
Pull the generator to out
5
Take out the Cable Remote Control
6
Press the button mast extension/lower of
remote control
7
The lights can operable up to 3600 angle by
starting the generator & pressing the concern
buttons.
8
Focus the lighting on desirable spot
9
After completion of the job, press down mark on
remote & ensure that the light robot sited
properly
10
Close the valve at air tank & put open the drain

Results

Remarks

11
12
13

valve
Cover the mast with hood
Circuit breaker & Ignition switch to be put off
Generator to be push inside & close the locker

HWP (M)

STANDARD OPERATING
PROCEDURE
LIGHT MAST- GENRATOR

DOC. NO. FR/EQP/32/6

BASIS:

Suppliers Maintenance instructions, Fire Service Manual &


Work experience.

ITEM:

MULTI PURPOSE TENDER.

Light Mast- Generator

Light Mast-Generator:
1

It can be used while fire fighting & rescue operations during night time where the
illumination is poor as explained in DOC. No.FR/EQP/32/13 & 14.
(Tick () for O.K & (X) for not O.K)
Sl.No.
1
2
3
4
5
6
7
8
9
10
11
12

Items of Test
Pull out it from locker
Ensure fuel to be full in the tank
Put on the fuel cock
Start the engine manually or auto
Connect the plug to AC out supply & ensure
that circuit breaker switch to be put on
After completion of the job put off the circuit
barker switch
Wait 10 minutes to cool the engine
Push it inside of locker
Close the fuel clock
Close the locker door
Record the purpose of use, time in concern
document
Report immediately to duty officer any
deficiencies are noticed.

Results

Remarks

HWP (M)

STANDARD OPERATING
PROCEDURE
FOR CO2 BANK

DOC. NO. FR/EQP/32/7

BASIS:

Suppliers Maintenance instructions, Fire Service Manual &


Work experience.

ITEM:

MULTI PURPOSE TENDER (MPT) - CO2 BANK

The CO2 extinguishing media is useful on B, C and electrical fires. It


consists 6nos, 22.5 kg cylinders. They can operable from locker no.4 & 10 of
MPT i.e., either side of the vehicle. .DOC. No.FR/EQP/32/13 & 14.
(Tick () for O.K & (X) for not O.K)
Sl.No.
1
2
3
4
5
6
7
8
9
10
11

Items of Test
Took the discharge device up to the spot
Open the header valve
Remove safety pin of cylinder
Open the cylinder valve in anti clock direction
one by one according to the situation demand
After completion of the job close the header
valve
Wind up the hose on CO2 reel
Re insert the safety pin to used cylinder (S)
After returning to Fire Station replace the used
cylinders with full cylinders
The cylinder capacity is less than 10% no need
for replacement
Record the same in concern records
Cylinders shall be hydro tested for every 5
years according to Gas cylinder Rules-2004

HWP (M)

STANDARD OPERATING
PROCEDURE
FOR DCP Extinguisher (s)

Results

Remarks

DOC. NO. FR/EQP/32/8

BASIS:

Suppliers Maintenance instructions, Fire Service Manual &


Work experience.

ITEM:

MULTI PURPOSE TENDER (MPT) - DCP Extinguisher (s)

The Dry Chemical Powder extinguishing media is useful on B, C and


electrical fires. It consists 2 nos, 50 kg cylinders and CO 2 gas cylinder in locker
No.4 &10 i.e., either side of the MPT. 2 Kg. CO2 cylinder provided to each
cylinder as a pillet cylinder. They can operable from locker no.4 & 10 of MPT i.e.,
either side of the vehicle. .DOC. No.FR/EQP/32/13 & 14.
(Tick () for O.K & (X) for not O.K)
Sl.No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14

Items of Test
Uncoil the discharge hose up to the spot
Operate the squeeze grip nozzle
Remove safety pin from CO2 pillet cylinder
Open the CO2 pillet cylinder valve slowly but
fully
Stay upwind direction
Direct the DCP on the seat of fire
If the fire is in confined space, close the
windows
Wear B.A. Set & follow buddy system with life
line.
After extinguishing the fire close pillet CO2
cylinder valve
Re-fix the safety pin to pillet CO2 cylinder
Coil the discharge hose
Return to Fire Station
Refill the DCP in cylinder & replace the CO2
cylinder with full.
If the CO2 is less than 10% no need to replace.

Results

Remarks

HWP (M)

STANDARD OPERATING PROCEDURE


FOR ALUMINIUM EXTENSTION LADDER

BASIS:

Suppliers Maintenance instructions, Fire Service Manual &


Work experience.

ITEM:

MULTI PURPOSE TENDER (MPT) 35 FEETS ALUMINIUM EXTENSTION


LADDER

DOC. NO. FR/EQP/32/9

It is mounted on the top of the MPT and secured in gallows with locking
provision to prevent fall down while the MPT is in motion. It is widely using for fire
fighting, Rescue operations, first floor ladder, improvised structure, used as
bridge between two buildings, to ascending & dis- ascending to top floor, ship
holds, confined spaces, basements, step ladder, to use in 4 men extension
ladder drill and to make water dam.
DOC. No.FR/EQP/32/13 & 14.
(Tick () for O.K & (X) for not O.K)
Sl.No.
Items of Test
1
Dismount & pitch the ladder at desired place
2
Hold it firmly
3
Extend the ladder by pulling extension rope,
confirm proper securing the safety locks
4
Pitch it on desired place, but 5 rounds shall be
above the parapet wall but maintain the safety
distance i.c., th. of the length of the ladder
5
Strings shall be caught by 02 members & 01
member firmly hold the round at behind
6
Climb/down the ladder by unison method
7
While coming down the ladder shall be left side
to fireman
8
After completion of the job, remove from
mounting place
9
Hold firmly & bring the extension portion in
original place by operating the extension rope
10
Mount the ladder on MPT & lock in gallows
11
Any deficiencies observed report to the duty
officer
12
After use it shall be tested according to the
standard

HWP (M)

STANDARD OPERATING PROCEDURE


FOR COMBI TOOL

Results

Remarks

DOC. NO. FR/EQP/32/10

BASIS:

Suppliers Maintenance instructions, Fire Service Manual &


Work experience.

ITEM:

MULTI PURPOSE TENDER (MPT) Combi Tool

Combi tool is provided in each MPT for lifting, cutting and spreading
purpose in case of an emergency.

(Tick () for O.K & (X) for not O.K)


Sl.No.
Items of Test
1
Take out the Combi tool box & open it
2
Take out the Combi tool from box & connect the
battery
3
Select the spreding/closing position on combi
tool
4
Select the position for speed /slow
5
Press the lock button & ensure it is properly
locked
6
Firmly hold the combi tool with both hands
7
Press the operating switch & use according
situation demand
8
After completion of the job, the spreader shall
be in normal position
9
Relase the lock & remove the battery
10
Ensure the battery should be properly charged
11
After charging clean the tool, battery charger &
battery with dry cloth
12
Install in the box & stowed in MPT
13
Any defects found report to shift-in-charge for
necessary action

HWP (M)

BASIS:
ITEM:

STANDARD OPERATING
PROCEDURE

Results

Remarks

DOC. NO. FR/EQP/32/22

Suppliers Maintenance instructions, Fire Service Manual &


Work experience.
Trailer Fire Pump (s):

A. From Fire Hydrant

(Tick () for O.K & (X) for not O.K)

Sl.No.
Items of Test
1
Hold the bars and caught firmly at bars rear
side
2
Disconnect hand brake
3
Safely remove the TFP from hook
4
Safely pull the TFP up to Fire hydrant
5
Park the TFP on hard surface & maintain the
6
7
8
9
10
11
12
13
14
15
16
17
15

Results

Remarks

level
Apply hand brake & put the legs in proper
position
Start the engine
Ensure all valve are closed position
Accelerate throttle as required
Use visual/whistle/line signals from starting to
completion of the work Strictly
Close all valves except cooling valve
Normalize the accelerator
Close the cooling valve
Stop the engine
Disconnect the hand brake
Hold the pulling bars, rear legs, loose & tight
them as required
Connect the towing hook to jeep/Fire Engine
Took & park the TFP at earmarked place on
legs

HWP (M)

STANDARD OPERATING
PROCEDURE
CONTD...

DOC. NO. FR/EQP/32/23

BASIS:

Suppliers Maintenance instructions, Fire Service Manual &


Work experience.

ITEM:

TRAILER FIRE PUMP (s):

B. Open Water source.

(Tick () for O.K & (X) for not O.K)


Sl.No.
Items of Test
1
Park the TFP on hard, level surface & near to water
source
2
Apply hand brake
3
Connect suction hoses, metal strainer & basket
strainer. Apply clove hitch on basket strainer &
submerged well in the water.
4
Apply half hitch on suction (s) joints
5
Apply half hitches & thumb knot to a hard object

Results

Remarks

6
7
8

Ensure all valves are in closed condition


Start the Engine
Accelerate throttle as required. Watch the compound
gauge & pressure gauge. If pressure gauge shown

9
10
11
12
13
14
15
16
17
18
19

positive pressure, Pump primed.


Connect delivery hose to delivery out let as required
Slightly open delivery valve but fully
Open cooling valve
As per the requirement of branch man accelerate
pressure by operating the throttle as required
Use visual/whistle/line signals from starting to
completion of the work Strictly
Close all valves except cooling valve
Normalize the accelerator
Close the cooling valve
Stop the engine
Remove rear legs, hand brake & hook to towing
vehicle
Park at designated place

HWP (M)

STANDARD OPERATING
PROCEDURE
CONTD...

DOC. NO. FR/EQP/32/24

BASIS:

Suppliers Maintenance instructions, Fire Service Manual &


Work experience.

ITEM:

TRAILER FIRE PUMPS (s):

C. After Use.

(Tick () for O.K & (X) for not O.K)


Sl.No.
Items of Test
1
Radiator tank, fuel tank & Engine oil shall be
replenished
2
Drain the water from pump casing
3
Top up water in priming box if required
4
Appliance, including the ancillary equipments
shall be thoroughly cleaned.
5
Apply grease to water pump, pump nipples &
U-J cross joints
6
Ensure proper fan belt tension
7
Check air pressure in all tyres
8
Check road wheel nuts. Tighten as necessary
9
Check & ensure all stowed equipments
working condition
10
Clean all lockers & cabin

Results

Remarks

11

Open bonnet door for 30 minutes for free air

12
13

passage
Check all spot light & meter lights
Necessary entries shall be made in concern log

14

book
Park the TFP in proper turnout place & report it
is ready for turnout.

HWP (M)

STANDARD OPERATING
PROCEDURE

DOC. NO. FR/EQP/32/25

BASIS:

Suppliers Maintenance instructions, Fire Service Manual &


Work experience.

ITEM:

PORTABLE FIRE PUMP (s):

A. From Fire Hydrant

(Tick () for O.K & (X) for not O.K)


Sl.No.
Items of Test
1
Park the vehicle on hard, level surface & near
to water source
2
Apply hand brake
3
Apply 2nd. gear & engage P.T.O. lever
4
Ensure all doors of cabin in closed condition
5
Ensure all valves are in closed condition
6
Connect delivery hose line between hydrant &
suction inlet or hydrant to tank
7
Slightly open one delivery valve to release the
8
9
10
11
12

air
Open cooling valve
Close the delivery valve & accelerate throttle
as required
Use visual/whistle/line signals from starting to
completion of the work Strictly
Close all valves except cooling valve
Normalize the accelerator

Results

Remarks

13
14

Close he cooling valve


Enter in cabin, disengage the PTO lever & 2nd.

15

gear
Check the air in air pressure gauge if required

16
17

to up
Check water level in water tank
Stop the engine

HWP (M)

STANDARD OPERATING
PROCEDURE

DOC. NO. FR/EQP/32/26

BASIS:

Suppliers Maintenance instructions, Fire Service Manual &


Work experience.

ITEM:

PORTABLE FIRE PUMP (s):

A. From Open Source Water

(Tick () for O.K & (X) for not O.K)


Sl.No.
Items of Test
1
Install the PFP on hard, level surface & near
to water source
2
Connect suction hoses, metal strainer & basket
strainer. Apply clove hitch on basket strainer &
submerged well in the water.
3
Apply half hitch on suction (s) joints
4
Apply half hitches & thumb knot to a hard
5
6
7

object
Ensure all valves are in closed condition
Start the Engine
Accelerate throttle as required. Watch the
compound gauge & pressure gauge. If pressure

8
9
10
11
12
13
14

gauge shown positive pressure, Pump primed.


Connect delivery hose to delivery out let as
required
Slightly open delivery valve but fully
As per the requirement of branch man
accelerate pressure by operating the throttle as
required
Use visual/whistle/line signals from starting to
completion of the work Strictly
Close all valves except cooling valve
Normalize the accelerator
Stop the engine

Results

Remarks

15

Keep it at designated place

HWP (M)

STANDARD OPERATING
PROCEDURE FOR EXHAUST
BLOWER

DOC. NO. FR/EQP/32/27

BASIS:

Suppliers Maintenance Instructions,


materials, BIS & Work experiences.

SCOPE:

EXHAUST BLOWER

Sl.
No.

OPERATING PROCEDURE

1
2
3
4
5
6
7
8
9
10

Keep the exhaust blower near to the scene


To take fresh air in to the confined area the
kerosene tank side duct should be kept inside of
confined space.
To exhaust the confined air into fresh air, the
petrol tank side duct should be inside & the
kerosene side duct should be out side
Start the engine by pulling the rope
After start, wait for few seconds and switch over
to kerosene running
After completion of the job, select the switch on
stop mark.
Safely remove the ducts, clean them roll and
stowed in safe place
Thoroughly clean the exhaust blower with dry
cloth
Top up the fuel
Any deficiency observed report to shift-in-charge

Date of
use

Standard

training

Result Remarks

HWP (M)

STANDARD OPERATING
PROCEDURE OF FIRE
EXTINGUISHERS

DOC. NO. FR/EQP/32/27

BASIS:

Suppliers Maintenance Instructions,


materials, BIS & Work experiences.

SCOPE:

CO2 Type, DCP Type, Foam (Mech.) & Water CO2 Type.

Sl.
No.

OPERATING PROCEDURE

1
2
3
4
5
6
7

8
9
10
11
12

1
2
3
4
5
6
7
8
9

10

Date of
use
CO2 TYPE FIRE EXTINGUISHER (S)

Standard

training

Result Remarks

Carry the extinguisher


Stay upwind direction
Approach the fire & stand at the safe distance
Pull the safety pin
Hold the discharge grip by hand & hold the
discharge valve with other hand
Open the valve slowly but fully in anti clock wise
direction
Sweep the discharge horn side to side as you
approach the fire directly the extinguishing
media at the base of the flame until the flames
appear to be out.
Watch the fire area closely & if fire restarts
repeat the above process.
If the fire is enclosed place cover your nose
with hand cut chief/ don B.A.Set
After extinguishing the fire ensure proper cross
ventilation
Ensure the valve is closed properly & put the
safety pin
Handed over the extinguisher for maintenance
& further action

DRY CHEMICAL POWDER TYPE FIRE EXTINGUISHER (S)


Carry the extinguisher
Stand upwind direction
Approach the fire & stand at the safe
distance
Hold the squeeze grip nozzle, operate it &
ensure that it is not used before
The operator shall keep his face safe from
extinguisher cap
Pull the safety clip
Strike the knob with other hand
Aim the discharge at the base of fire
Sweep the discharge hose side to side as
you approach the fire & direct the
extinguishing media on the base of fire until
the fire appear to be out
If the fire is closed room, close all doors &

11
12
13

windows
Don B.A. set/cover the nose with hand cut
chief
After extinguishing the fire made proper
cross ventilation
Handed over the extinguisher for
maintenance & further action
FOAM FIRE EXTINGUISHER (S)

1
2
3
4
5
6
7
8
9

10
11
12
13

Carry the extinguisher


Stand upwind direction
Approach the fire & stand at the safe
distance
Hold the discharge tube towards the fire
The operator shall keep his face safe from
extinguisher cap
Pull the safety clip
Strike the knob with other hand
Aim the discharge at the edge of the
container and strike the knob
Apply extinguish media at the edge of the
container so that foam will float on the
burning surface
If the fire is closed room, close all doors &
windows
Don B.A. set/cover the nose with hand
cherchief.
After extinguishing the fire made proper
cross ventilation
Handed over the extinguisher for
maintenance & further action
WATER CO2 FIRE EXTINGUISHER (S)

1
2
3
4
5
6
7
8
9
10
11

Carry the extinguisher


Stand upwind direction
Approach the fire & stand at the safe
distance
Keep the extinguisher nozzle in 40 to 45
degrees angle
The operator shall keep his face safe from
extinguisher cap
Pull the safety clip
Strike the knob with other hand
Lift the extinguisher and apply the media on
the seat of the fire
According to convenient the operator can
extinguish the fire by moving any direction
If the fire is closed room, close all doors &
windows
Don B.A. set/cover the nose with hand
cherchief.

12
13

After extinguishing the fire made proper


cross ventilation
Handed over the extinguisher for
maintenance & further action

Remember - PASS
PASS-

Pull pin
Aim Nozzle at base of fire
Squeeze Handle
Sweep from side to side

The above principles are recently recognized by National and


International for stored pressure type portable fire extinguishers.

HWP (M)

STANDARD OPERATING
PROCEDURE FOR HIGH
EXPANSION FOAM
GENERATOR

DOC. NO. FR/EQP/32/27

BASIS:

Suppliers Maintenance Instructions,


materials, BIS & Work experiences.

SCOPE:

HIGH EXPANSION FOAM GENERATOR

Sl.
No.
1
2
3
4
5
6
7
8
9
10
11

OPERATING PROCEDURE
Connect delivery hose between hydrant and
hydrant to tank
Open the tank to pump foam valve
Select the Foam selector valve according to
foam concentration percentage
Connect the discharge outlet of the pump to
foam inlet of Hi-expansion foam generator inlet
using delivery hose
Increase the pump pressure up to 7kg/cm2
Open the delivery valve slowly but fully
Direct the Hi-expansion foam at desired place
After completion of the job close the foam
selector valve, delivery valve
Normalize the throttle.
Disconnect the foam generator connection
Wash thoroughly foam generator and concerned
equipments with fresh water

Standard

training

FROM PUMP

Date of
use

Result Remarks

HWP (M)

STANDARD OPERATING
PROCEDURE FOR HIGH
EXPANSION FOAM
GENERATOR

DOC. NO. FR/EQP/32/27

BASIS:

Suppliers Maintenance Instructions,


materials, BIS & Work experiences.

Standard

SCOPE:

HIGH EXPANSION FOAM GENERATOR


CONNECTION

FROM AUXILLERY

Sl.
No.
1
2
3
4
5
6
7
8
9
10
11

OPERATING PROCEDURE
Connect delivery hose pipe to auxiliary
connection.
Dip the pickup tube in foam drum
Select the Foam selector valve according to
foam concentration percentage
Buildup the pressure up to 7kg/cm2
Increase the pump pressure up to 7kg/cm2 in the
pump
Connect the delivery hose between pump and
HX foam generator
Direct the Hi-expansion foam at desired place
After completion of the job close the foam
selector valve, delivery valve
Normalize the throttle.
Disconnect the foam generator connection and
other connections
Wash thoroughly foam generator and concerned
equipments with fresh water

Date of
use

training

Result Remarks

HWP (M)

BASIS:

STANDARD OPERATING
PROCEDURE FOR
OSCILLATING MONITOR

DOC. NO. FR/EQP/32/27

Suppliers Maintenance Instructions,


materials, BIS & Work experiences.

Standard

training

SCOPE: OSCILLATING MONITOR


Sl.
No.
1
2
3
4
5
6
7
8
9
10
11

OPERATING PROCEDURE
Took the monitor and place on equal hard
surface
Lay delivery hose across front legs within 10 feet
diameter hose loop minimum and give input
pressure.
Tighten the belts on hose
Maximum flow is 375 GPM
The minimum pressure required 10kg/cm2
Select discharge rate then adjust the nozzle as
per demand i.e., spray or jet
Put the button on ON condition for oscillating
Depend up on the requirement set the
adjustment levers for oscillation
Normalize the throttle.
After completion of the job, normalize the
pressure and normalize the above procedure
Wash thoroughly and clean. Stowed at
designated place.

Date of
use

Result Remarks