DUNHAM-BUSH WARRANTY SERVICE DIVISION

DB-AIRE STARTUP LOG


SITE INFORMATION
Job Name
Address
Unit No.

Installing Contractor
Unit Location

Area Served

NAMEPLATE DATA
Unit Details
Model

Serial No.

Factory Order

Indoor Unit
Outdoor Unit (DX Units)
Blower Motor
Model
Volt
RPM

Serial No.
Phase
kW/HP

Manufacturer
FLA

Hz
Type

Compressors (DX Units only)


Compressor 1
Model
Serial No.
V / Ph / Hz
/
/
FLA / LRA
/

Compressor 2

LRA

Compressor 3

/
/

Condenser Fans (DX Units only)


Serial No.

Model

General

1)
2)
3)
4)
5)
6)

Volt
Phase
Hz
FLA
LRA
HP/kW

Electric Heaters
Model

Serial No.

General

1)
2)
2)
4)
5)
6)

Volt
Phase
Hz
FLA
LRA
HP/kW

Humidifier
Model
Volt

Serial No.
Phase

Hz

Manufacturer
kW/HP

kg

DESIGN DATA
Cooling Capacity
Heating Capacity

Design Airflow
Design T S P

Blower RPM

Form No. DBWS 1009A


Page 1

BLOWER & COIL


Blower Section
Blower Model
Blower Pulley Model
Motor Pulley Model

Size
Size
Size

Fan Belt Model


Fan Belt Size
Quantity

Coil Section
Coil Type

Direct Expansion

Chilled Water

Hot Water / Steam

Coil Material

Aluminium

Copper

Hydrophilic

Coil Arrangement

FPI

Length

Filter Type

Filter Size 1)
2)
3)

Height

# Rows

X
X
X

# Filters
# Filters
# Filters

ELECTRICAL
Contactors
Model, Rating

Serial No.

Qty

Type of Starters

Blower Fan

DOL

SD / AT

Comp. 1

DOL

SD / AT

Comp. 2

DOL

SD / AT

Comp. 3

DOL

SD / AT

Cond. Fan 1
Cond. Fan 2
Cond. Fan 3
Cond. Fan 4
Cond. Fan 5
Cond. Fan 6
Heater 1
Heater 2
Heater 3
Heater 4
Heater 5
Heater 6
Humidifier

Winding Insulation Test


Blower Motor
L1
L2
L3

Compressor 1
M
M
M

L1
L2
L3

Compressor 2
M
M
M

L1
L2
L3

Compressor 3
M
M
M

L1
L2
L3

M
M
M

Form No. DBWS 1009A


Page 2

PRESTARTUP CHECK LIST


1) Shipping, Transportation, Installation, Handling, or any other damages?

Yes

No

2) Short shipped components or accessories?

Yes

No

3) Unit installed in accordance with the technical specifications provided?

Yes

No

4) Steel brackets or wooden blocks against transportation damage removed?

Yes

No

5) Fan deck leveled and has sufficient clearance from the foundation?

Yes

No

6) Blower wheel mounted concentrically wrt the blower housing?

Yes

No

7) Blower wheel has sufficient clearance from the edge of the inlet cones?

Yes

No

8) Bower wheel mounted onto the shaft and setscrews tightened firmly?

Yes

No

9) Blower shaft mounted onto the bearings and setscrews tightened firmly?

Yes

No

10) Blower pulley and motor pulley aligned and setscrews tightened firmly?

Yes

No

11) Bearings mounted firmly onto the framework or structure?

Yes

No

12) Fan belt of the same size and type. Belt tension checked and acceptable?

Yes

No

13) Motor bracket fastened firmly onto the rail without any loose motion?

Yes

No

14) Motor and shaft bearings greased and lubricated?

Yes

No

15) Rotating parts free to rotate whenever they are rotated manually?

Yes

No

16) Drain pipe and "U" trap installed?

Yes

No

17) Permanent return air filters or any other temporary filters installed?

Yes

No

18) Any object or rubbish that would be sucked into the blower removed?

Yes

No

19) Water strainer installed and cleaned by the contractor (optional) ?

Yes

No

20) Motor resistance above minimum resistance required for startup?

Yes

No

1) Incoming power supply tested for correct phase sequence, voltage, etc?

Yes

No

2) Auxiliary 24VAC supply to DB-Aire controller tested?

Yes

No

3) Setpoints verified and control sequence tested for functionality?

Yes

No

4) Fan motor tested for correct rotation. Current drawn less than 1.1 x FLA?

Yes

No

A) DX Unit :- Compressor tested for correct rotation and functionality?

Yes

No

B) Chilled water Unit :- Actuator or modulating valve tested for functionality?

Yes

No

6) Increase room temperature setpoint. Reheaters tested for functionality?

Yes

No

7) Increase room humidity setpoint. Humidifier tested for functionality?

Yes

No

8) Air differential sensor and air flow sensor tested for functionality?

Yes

No

9) Humidity sensor and temperature sensors tested for accuracy?

Yes

No

STARTUP CHECK LIST

5) Decrease room temperature setpoint,

10) Condensate pump installed and tested for functionality (opt)?

NA

Yes

No

11) Smoke detector installed and tested for functionality (opt)?

NA

Yes

No

12) Water detector installed and tested for functionality (opt)?

NA

Yes

No

13) Fire relay installed and tested for functionality (opt)?

NA

Yes

No

14) Sign of vibration or abnormal noise?

Yes

No

15) Sign of air leakage or condensation?

Yes

No

Form No. DBWS 1009A


Page 3

USER DEFINED SETPOINT


1) Room Temperature Setpoint

2) Room Humidity Setpoint


SERVICE DEFINED SETPOINT

PROBE CALIBRATION
1) Room Temperature
2) Supply Air Temperature
3) Room Humidity

4) Spare
5) Spare
6) Spare

CONTROL SETPOINT
1) Temperature Control Type
2) Proportional Band
Temperature

P+I

Integration Time

Humidity

Secs

Temp Dead Zone

3) Auto Restart

Yes

No

Unit Delay On

Secs

4) Remote On

Yes

No

Customer Interlock Delay On

Secs

SETPOINT RANGE

MIN

MAX

MIN

MAX

1) Room Temperature Setpoint


2) Room Humidity Setpoint
ALARM / WARNING SETPOINT
1)
2)
3)
4)
5)

DELAY

Room Temperature
Room Humidity
Unit Overheat Alarm
Air Flow Alarm
Water Detector Alarm

Secs
Secs
Secs
Secs
Secs

DEHUMIDIFIER SETPOINT
1) On Humidifier Temperature
DAILY TIME ZONE
Time Zone 1
Start
Hrs
Stop
Hrs
WEEKLY TIME ZONE
Monday
Turn On
Turn Off

Time Zone 2

Time Zone 3
Hrs
Hrs

Tuesday
Hrs
Hrs

Friday
Turn On
Turn Off

2) Off Humidifier Temperature

Hrs
Hrs

Wednesday
Hrs
Hrs

Saturday
Hrs
Hrs

Time Zone 4
Hrs
Hrs

Thursday
Hrs
Hrs

Hrs
Hrs

Sunday
Hrs
Hrs

Hrs
Hrs

Form No. DBWS 1009A


Page 4

OPERATING PARAMETERS
Job Name
Job Location

Unit Model
Unit Serial No.

Date
F/O

Temp
SSH
Condenser

DX UNIT

System 1

System 2

System 3

System 1

System 2

System 3

Amperage

F
PSI
F
PSI

Suction Pressure PSI


Disch. Pressure
PSI
Liquid Pressure
PSI
Suction Temp
F
Disch. Temperature F
Liquid Temperature F
Suction Superheat F
Disch. Superheat
F
Subcooling
F
On Coil (Dry Bulb) F
(Wet Bulb) F
Off Coil (Dry Bulb) F
(Wet Bulb) F
Blower Fan
Compressors

A
A

Condenser Fans

A
Heaters

Voltage

ELECTRICAL

Actual

Evaporator

Chilled Water
Inlet
Chilled Water
Outlet

Pressure

CHRW

GENERAL

DB-Aire Display
Room Temperature
F
Room Humidity
%
On Coil (Dry Bulb) F
(Wet Bulb) F
Off Coil (Dry Bulb) F
(Wet Bulb) F

L1~L2
L1~L3
L2~L3

A
V
V
V

REMARKS

Commissioned by

Date of Commissioning

Form No. DBWS 1009A


Page 5