Beruflich Dokumente
Kultur Dokumente
Pure Tone
Speech
HF
Two earphones
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
Insert earphones
Yes
No
No
No
No
No
No
No
No
Loudspeakers or electrical
output
Yes
Yes
No
No
No
No
Yes
Yes
No
Bone vibrator
Yes
Yes
Yes
No
No
No
Yes
No
No
Yes
Yes
Yes
Yes
Yes
No
Yes
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Transducers
Pulsed tone
Yes
Yes
No
Yes
No
Yes
No
No
No
Frequency modulation
(FM)
Reference Tone
Alternate presentation
Simultaneous
presentation
Speech Input
Replay device
Or electrical
Input for recorded
material
Microphone
Masking
Narrow band noise
White noise
Speech Spectrum noise
Routing of Masking
Contralaterial earphone
Ipsilateral earphone
Loudspeaker
Routing of Masking
Contralateral earphone
Ipsilateral earphone
Loudspeaker
Bone Vibrator
Subject Response
System
Signal indicator
Audible Monitoring
Operator to subject
speech communication
Talk Back system
Yes
Yes
No
No
No
No
No
No
No
Yes
Yes
Yes
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
Yes
No
Yes
No
No
No
No
No
No
No
No
No
Yes
No
Yes
No
Yes
No
No
No
No
No
No
Yes
Yes
No
Yes
Yes
No
Yes
Yes
No
Yes
No
No
No
No
No
No
No
No
Yes
No
No
No
No
Yes
No
No
Yes
No
No
Yes
Yes
Yes
Yes
Yes
No
Yes
Yes
No
No
No
No
No
N
No
No
Yes
No
No
Yes
Yes
Yes
Yes
No
Yes
Yes
No
No
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
No
Yes
Yes
No
No
No
Ys
No
No
No
No
Yes
N
No
No
No
No
Yes
No
No
N
Yes
Yes
Yes
Yes
No
Yes
Yes
No
Yes
No
No
Yes
No
No
No
No
Yes
Yes
Yes
Yes
No
No
No
No
No
No
No
No
No
No
No
Yes
No
No
Yes
Yes
Yes
Yes
Yes
No
Yes
No
No
No
No
No
No
No
No
Yes
Yes
No
Type 1
Freq
(Hz)
125
250
500
750
1000
1500
2000
3000
4000
6000
8000
AC
BC
AC
Type 2
BC
AC
Type 3
BC
Type 4
AC
70
90
120
120
120
120
120
120
120
110
100
45
60
60
70
70
70
70
60
50
-
60
80
110
110
110
110
110
110
100
90
45
60
70
70
70
70
60
-
70
100
100
100
100
100
90
80
35
50
60
60
60
50
-
70
70
70
70
70
70
-
Table 2: Minimum required freq. and HLs for Pure Tone Audiometers
(ANSI S 3.6, 1996)
TYPE 4 - AUDIOMETER
Technical specifications:
Hearing Level Range: -10 to 90 dB HL in 5 dB steps
Tone Stimulus: Pure tone
Frequency Range: 125 to 8,000 Hz
Accuracy:
a) Frequencies: better than 3%
b) Hearing Level: within 3 dB of indicated level from 125 to 5000Hz & 5
dB at 6000 Hz and higher.
Total Harmonic Distortion: < 2%
Standards: EN 60645-1 for Audiometers, Type 4
Calibration: IEC 645, ANSI S3.6 for Type 4 audiometers.
AC dBHL
BC dBHL
NB dBHL
125
250
500
1000
2000
3000
4000
6000
8000
90
110
120
120/130
120
120
120
120
120
45
65
70
75
80
80
55
50
80
100
100
110
110
110
110
110
100