Abstract
Solar water heaters (SWH) are becoming increasingly attractive in sustainable
development. Efforts are continuously made to reduce their costs to make them more affordable. We
Mechanical Engineering Students of Saint Louis University Baguio City has designed a low cost SWH
that uses recycled PET bottles as solar collector and solar reflectors to maximize the heat absorb by the
water. This project focused on a comprehensive feasibility analysis of the use of the SWH here in Baguio
City. Our feasibility analysis of the SWH is consisted mainly of two sections: 1) the design of the passive
type SWH, 2) the heating performance of the SWH.
Human skin can tolerate a temperature of 35C up to 45C.The design of the passive SWH has an
average temperature of 36C and with the aid of the solar reflectors the SWH does achieve the desired
temperature of 40C. It further showed that most of our data gathered was warm enough to be used in
washing and bathing. The heating performance was very dependent on the weather condition (sunny,
cloudy, etc.) but we can say that it has a capability to produce warm water for household chores on a
slightly cloudy weather condition. But because of the lack in insulation of the storage tank the 40C
temperature wont last enough to reach until the next day. Finally, further design for the solar reflectors
should consider the material to be used and the curvature of the solar reflectors. And we recommend
proper insulation for the storage tank to minimize heat loss and we also recommend finding a place where
it can absorb heat in the North, East, West, and South for the utilization of the solar energy.
I.
solar water heater which can be integrated in the households of Baguio City where hot water can be
strongly considered a necessity.
The basics of solar water heater
The operation of a solar water
heater can be best understood with the
use of a diagram. Figure 1 (Ong, 2011)
shows a schematic diagram of a natural
convection solar water heater with a flatplate collector. The solar collector is one
of the main parts of a solar water heater.
It is a mechanical device which captures
the radiant solar energy and converts it
to useful thermal energy (Jesko, 2008).
Other major parts include the thermal
Figure 1: A natural convection solar water with flat plate collector
(Ong, 2011).
this regard and the proven benefits of the solar water heater in reducing the energy consumption and
greenhouse gases emissions of a household, the researchers decided to fabricate a passive, direct-type
solar water heater using PET bottles as solar collectors in substitute for the evacuated glass tubes of
commercially available solar water heater systems. The idea of using PET bottles as solar collectors came
from a similar passive solar water heater in Southern Brazil that utilized soda bottles as solar collectors.
The said water heater is self-built; hence, low-cost, and claims the ability to heat water up to 41 C given a
quite cloudy weather condition. The researchers adapted this idea, but unfortunately, the said project has
no formal write-up. The researchers came up with the idea of fabricating a similar design and testing it in
the city of Baguio, wherein hot water can be considered a necessity.
PET or polyethylene terephthalate, is a long chain polymer belonging to the generic family of
polyester. PET is formed from the intermediates terephthalic acid (TPA) and ethylene glycol (EG), which
are both derived from oil feed stock
Non-biodegradable polyethylene terephthalate (PET) bottles have attracted the increasing
attention due to environmental concerns in today's world (Issam, 2013). This material is fully recyclable
and may be used for manufacturing new products in many industrial fields. But this excellent properties
of PET with all of its many applications are also responsible for the difficult degradation of PET and the
accumulation of polymer waste, which in turn creates a serious environmental problems connected to
littering and illegal landfilling or incineration (Sirocic, Fijacko, and Hrnjak-Murgic, 2013). The
researchers decided to use PET bottles as a substitute for glass in the thermosiphon system due to the
properties and advantages mentioned above.
Khalimov et al (2011) provided a report on the thermophysical characteristics of PET bottles as
an element of water heat accumulators in solar applications. The report stated that PET is of high light
transparency (88 90% transmission) which makes it a good substitute for glass in the conventional solar
water heater designs wherein breakage is imminent at any time. In addition, the PET is thermally stable
within the operating conditions of the solar water heater as it only starts to soften at 245 C and melts at
260 C. Madhukeshwara and Prakash (2012) specified the operating range of solar water heaters at a
certain ambient temperature up to 100 C.
II.
IV.
Conceptual Framework
The design and development of a passive solar water heater integrating PET bottles as its solar
collectors and conducting tests to evaluate its performance is the main concept of this project study. The
conceptual framework provides the interconnection of different variables and components to be used in
the study. The framework is stratified into three phases, namely: input, process, and output.
The input is consisted of the variables to be tested or to be circulated. Moreover, the input serves
the function of the working fluid, component, or mechanism. The cold water supply serve as the input of
the passive SWH project as it is one of the variables to be tested and circulated in the said research. The
cold water is to be heated with the use of the developed design and it will gauge the effectivity of the said
design. In addition, the three variations of project design is also included in this section.
The project design and the subsequent water heating operations and the data gathering procedures
and analyses comprised the process phase. The resulting project design is discussed in the design and
fabrication section of the project manuscript. The water heating operations was carried out during
daytime. The data gathering procedure have been a tedious task as temperatures were taken during the
varying times of the day. Corresponding graphs and data tabulations were also carried out.
The output of the project study is consisted of a supply of hot water at a temperature of 40 C that
is to be stored in a thermal storage tank, a detailed tabulated data of results and their corresponding graphs
that is plotted against the time they were obtained for the different times of the day, and a comprehensive
analysis of these values and results.
Input
Cold water
PET Bottles
Three different
project settings
Process
Output
Hot Water
Detailed
Tabulated Data of
Results
V.
Research Design
The research is composed mainly of three activities as stated in the project title: 1) design, 2)
fabrication, and 3) performance testing and evaluation. For the design phase of the study, the researchers
have already made an initial draft of the passive solar water heater with the utilization of PET bottles as
solar collectors. The design concept was adapted from commercially available evacuated glass tube solar
water heating systems in which circulating water pipes are arranged in parallel and the thermal storage
tank is above these pipes. According to a study by Kumar et al (2011), solar water heaters in parallel
configuration give a 0.5 2.5 C higher output water temperature than solar water heaters in series
configuration. The designs were varied in three different settings, namely: 1) bare black pipe only, 2) pipe
with PET bottles only, and 3) pipe with PET bottles with reflector.
For the fabrication phase, a time period of one month was given. The researchers deemed this
length of time enough to complete the actual project model. The fabrication phase also included the
purchase of materials. Activities done in this phase include basic machine shop processes, such as pipe
threading, metal cutting, welding, measuring, dimensioning, and other processes deemed necessary have
been applied by the researchers.
Lastly, for the performance evaluation, a time period of one month was allotted for this phase.
The researchers have conducted the experiment on the rooftop of Hugo Del Baere Bldg. at the Sunflower
Halfway Home for Boys of Saint Louis University, Baguio City. The tests were conducted on a daily
basis, and water temperatures were taken at specified times of the day. The data gathering was conducted
from 8:00 am to 4:00 pm, and inlet and outlet water temperatures was hourly taken and every 15 minutes
on an occasional basis. As for the weather conditions and ambient temperatures were recorded.
The researchers view on performance evaluation include the effectivity of the designed system.
The designed system will be considered effective if it will heat the water to 40 C or more for the hour of
operation.
For better and easier facilitation of the research, the stated specific questions will guide the
researchers in the research process:
1.) Does the designed passive solar water heater accomplished its objective of heating the water
to the desired temperature of 40 C within the given required span of time?
This guide question will be answered through the conducting of an hourly temperature
measurement of water in the thermal storage tank. The thermal storage tank and the tubes will be
completely filled with water to effectively facilitate the thermosiphon process. Since the
temperature is hourly obtained, effectivity is also determined every hour. The system will be
regarded effective if the obtained temperature of the water in the thermal storage tank reached 40
C.
2.) How effective is the water heating performance of the designed project given the different
weather conditions of Baguio City?
This guide question is in relation with the first question, but this question is geared towards the
performance of the designed system that is relative to the geographical location, which is, Baguio
City. The parameters included in answering this guide question are the local atmospheric
pressure, hourly ambient temperature.
Materials and Instrumentation
For the design phase of the study, the materials that have been utilized were mostly academic in
nature, such as research journals, design handbooks, manuals, textbooks, product brochures, and others.
These materials provide the necessary information in forging a proper effective and efficient model
design.
For the fabrication phase of the study, the materials that have been employed are the tools used in
machine shop processes such as steel rules, measuring tapes, hack saws, welding machine, and others.
Accuracy, precision, and safety were required in the use of these tools in fabricating the model.
For the performance testing and evaluation, the needed instruments include thermometers and
timers. Other pertinent data such as the ambient temperature was obtained from PAGASA Baguio
Complex.
VII.
Quantity
20m
8pcs
5pcs
2pcs
60ft
1kilo
3 pc
1/2 kilo
4yards
1pc
20pcs
3pcs
2pcs
20ft
40ft
3ft x 8ft
2pcs
Project Sketch
Figure 3: Ideal project sketch. The design resembles the commercially-available solar water
heaters (evacuated tube type)
Time
9:00
10:00
11:00
12:00
1:00
2:00
3:00
Outlet
temperature, C
36
40
35.5
39.3
42
42
41
Ambient
temperature, C
22
20.9
19.7
18.8
18.5
18.3
18
Table 2: Solar Water Heater Temperatures with PET Bottles as the Solar
Collectors
On March 9, 2016, the set-up of the solar water heater was pipes with PET bottles as solar
collectors without steel reflectors. The maximum outlet temperature recorded was 42 degrees Celsius at
1:00 and 2:00 PM while the average outlet temperature from 10:00 AM to 1:00 PM was 39.2 Degrees
Celsius. Outlet temperature varied positively from 9:00 to 10:00 AM and from 11:00 AM to 1:00 PM.
During this day, the weather condition was sunny.
50
40
30
20
10
0
9:00
10:00
11:00
12:00
1:00
TEMP.(STORAGE MIDDLE)
TEMP.(INLET)
TEMP.(OUTLET)
TEMP.(AMBIENT)
2:00
3:00
Figure 4: Line graph showing the behavior of the different parameters observed for the PET
Bottles Only Setup
Time
10:00
11:00
12:00
1:00
24
24
24
24
Inlet
Outlet
temperature, C temperature, C
31
32.5
25.5
29
Ambient
temperature, C
33
34
31.5
30
20.4
19.4
18.4
18.1
Table 3: Solar Water Heater Temperatures with Bare Pipes as the Solar
Collectors
On March 15, 2016 the set-up of the solar water heater was bare pipes without steel reflectors. The
maximum outlet temperature recorded was 34 degrees Celsius at 11:00 AM while the average outlet
temperature from 10:00 AM to 1:00 PM was 32.125 degrees Celsius. At the peak hours, the inlet
temperature always remained higher than the storage temperature. Water at the tank storage did not
increase in temperature during the peak hours. During this day, the weather condition was sunny.
40
35
30
25
20
15
10
5
0
10:00
TEMP.(STORAGE MIDDLE)
11:00
12:00
TEMP.(INLET)
TEMP.(OUTLET)
1:00
TEMP.(AMBIENT)
Figure 5: Line graph showing the behavior of the different parameters observed for the Bare Pipes Only Setup
Time
9:00
10:00
11:00
12:00
1:00
2:00
3:00
4:00
Inlet
temperature, C
29.1
29.5
30.25
30
29
32.9
30
29
Outlet
temperature, C
39
41.3
44.5
42.5
40.5
37
35.7
34
Ambient
temperature, C
20.8
20.1
19.5
18.8
18.5
18.2
17.8
17.7
On March 21, 2016 the set-up of the solar water heater was pipes with PET bottles as solar
collectors with steel reflectors. The maximum outlet temperature recorded was 44.5 degrees Celsius at
11:00 AM while the average outlet temperature from 10:00 AM to 1:00 PM was 42.2 Degrees Celsius.
Outlet temperature varied positively from 9:00 to 11:00 AM while tank storage temperature varied
positively from 9:00 AM to 2:00 PM. During this day, the weather condition was sunny and the relative
humidity ranged from 88% to 96% humid from 9:00 AM to 4:00 PM.
50
45
40
35
30
25
20
15
10
5
0
9:00
10:00
11:00
12:00
TEMP.(STORAGE MIDDLE)
1:00
TEMP.(INLET)
2:00
TEMP.(OUTLET)
3:00
4:00
TEMP.(AMBIENT)
Figure 6: Line graph showing the behavior of the different parameters observed for the PET
Bottles with Steel Reflectors Setup
9:00
10:00
11:00
12:00
28
28
31
33
Inlet
temperature,
C
28
30
32
33
10
Outlet
temperature, C
Ambient temperature, C
44
42
44
44
21.8
20.9
20
19.2
1:00
2:00
3:00
4:00
34
36
36
36
28
29.5
33
31
37
36.5
39
37
19
18.8
18.6
18.2
On March 22, 2016 the set-up of the solar water heater was pipes with PET bottles as solar
collectors with steel reflectors. The maximum outlet temperature recorded was 44 degrees Celsius at 9:00
AM, 11:00 AM and 12:00 NN while the average outlet temperature from 10:00 AM to 1:00 PM was
41.75 Degrees Celsius. Water at tank storage temperature varied positively from 10:00 AM to 2:00 PM.
At 1:00 PM, the outlet temperature dropped below 40 degrees Celsius and was recorded to be 37 degrees
Celsius but at the same time, the storage temperature is steadily increasing and approaching the outlet
temperature. During this day, the weather condition was sunny.
50
45
40
35
30
25
20
15
10
5
0
9:00
10:00
11:00
TEMP.(STORAGE MIDDLE)
12:00
1:00
TEMP.(INLET)
2:00
3:00
TEMP.(OUTLET)
4:00
TEMP.(AMBIENT)
Figure 6: Line graph showing the behavior of the different parameters observed for the PET
Bottles with Steel Reflectors Setup
Time
9:00
10:00
11:00
12:00
1:00
2:00
3:00
24.5
25
26
28
26
27
29
Inlet
temperature,
C
34.5
29.5
26
26
25
31
30
Outlet
temperature, C
Ambient temperature, C
38
47
36
36
53
41
40
22
21.1
20.3
19.4
18.7
18.3
17.8
On March 31, 2016 the set-up of the solar water heater was pipes with PET bottles as solar
collectors with steel reflectors. The maximum outlet temperature recorded was 53 degrees Celsius at 1:00
11
PM, while the average outlet temperature from 10:00 AM to 1:00 PM was 43 Degrees Celsius. Water at
tank storage temperature varied positively from 9:00 AM to 10:00 PM and from 12:00 NN to 1:00 PM.
The outlet temperature dropped below 40 degrees Celsius at 9:00 AM, 11:00 am and 12:00 NN even
though temperatures were high at 10:00 AM and 1:00 AM. Storage temperature also did not went over 30
degrees Celsius. During this day, the weather condition was sunny.
60
50
40
30
20
10
0
9:00
10:00
TEMP.(STORAGE MIDDLE)
11:00
12:00
TEMP.(INLET)
1:00
TEMP.(OUTLET)
2:00
3:00
TEMP.(AMBIENT)
Figure 7: Line graph showing the behavior of the different parameters observed for the PET
Bottles with Steel Reflectors Setup
General Observations
The solar water heater with PET Bottles as solar collector with steel reflectors has generally
higher outlet and storage temperature, followed by solar water heater with PET bottles as solar collector
without steel reflectors. When the solar water heater only has bare pipes as its solar collector, the
temperature were lower than when the PET bottles were present, and during this set-up, the tank storage
temperature also remained consistently low and did not increase.
The outlet temperature tend to increase from 9:00 AM to 12:00 NN and will then decrease as the
hours pass by. During this phenomena, the storage temperature will start to increase at around 10:00 AM
to 1:00 PM and will start to approach the outlet temperature. It is also important to note that at the
location and angle of the set-up of the solar water heater, the main heat source, which is the sun, is
unobstructed by building structures and trees from around 9:00 AM to 12:00 NN but could be obstructed
by thick clouds. At around 1:00 PM, sunlight is still unobstructed but will pass over the solar water
heater, making the angle and direction at which the solar water heater was placed ineffective. At around
3:00 to 4:00 PM, the sun will be obstructed by the SLU Hospital during the data gathering period on
March 2016.
The extended data for March 22, 2016 shows a pattern on the solar water heater temperatures. It
shows that outlet temperature will start to increase first and reach its peak before gradually decreasing. An
hour or two after the outlet temperature increases, the storage temperature will start to increase gradually
and will approach the outlet temperature which is now gradually decreasing. When the outlet and storage
temperatures are almost equal, both will then start to increase again during the peak hours. At around past
12:00 NN, the storage and outlet temperature will start to decrease but with the latter decreasing more
rapidly. It is important to note that the outlet temperature varies more frequently and faster than the
storage temperature.
12
Performance Comparison
With the three settings, the PET bottles with reflector gave the highest outlet water temperature
readings with 53 C as the highest recorded water temperature and 42.3 C as the average hot water outlet
temperature from 10:00 am to 1:00 pm. The PET bottles only setting gave 42 C as the highest recorded
water temperature with an average of 39.2 C from 10:00 am to 1:00 pm. The bare pipe setting gave the
lowest temperature readings for hot water outlet with just 34 C as its maximum value and 32.1 C as its
average value for the similar times as the two settings aforementioned.
Conclusions
The designed passive solar water heater system utilized PET bottles as its solar collectors as
compared to conventional SWH systems available in the market that use evacuated glass tubes to
facilitate the thermosiphon process. There were occurred variations from the original design to the
resulting outcome of the project during the fabrication phase. However, despite the changes that have
transpired, the project have still successfully demonstrated the thermosiphon principle and have produced
hot water with temperatures above 40 C given the 220L volume. Since this project is weather dependent,
variation of resulting trends from the data gathered can be observed and peak hours where water
temperatures above 40 C is also changing. There were three settings that have been observed, namely, (1)
PET bottles only, (2) bare black pipes only, and (3) PET bottles with reflector. For the first setting, the
highest water temperature recorded was at 42 C and the average hot water temperature from 10:00 am to
1:00 pm is 39.2 C. For the second setting, the highest water temperature recorded was at 34 C and the
average hot water temperature from 10:00 am to 1:00 pm is at 32.1 C. For the third setting, the highest
water temperature was recorded at 53 C and the average hot water temperature for the similar time
periods as with the first two settings was at 42.3 C. From the three settings, the best system that have
performed is the PET bottles with reflector.
Recommendations
In the undertaking of this study, the group identified some areas to improve. These areas are
material application, size variation, and site selection. For material application, the type of thermal
insulation of the tank will be tackled. Improving the insulation is hypothesized to improve the effectivity
of the system in that the hot water outlet temperature will increase. Moreover, in the same area, changing
the galvanized iron pipes to copper pipes is also hypothesized to fu+rther raise the water temperature as
heat transfer will increase due to higher thermal conductivity properties of copper compared to steel.
Another problem encountered is the moisture accumulation inside the PET bottles due to insufficient
sealing property of the adhesive used. The moisture that have accumulated have negatively affected the
convective heat transfer process as it reduced the amount of heat being received by the black pipes.
Hence, usage of an adhesive which has good sticking properties when it comes to PET bottles will ensure
an airtight condition within the PET bottle. For the size variation area, reducing the pipe diameter to fit
common PET bottles is highly recommended as this will speed up the fabrication process. Lastly, for site
selection, the project could be experimented in other places where it can maximize its obtainable sunlight.
Acknowledgement
A huge amount of gratitude is given to all the staff of SLU Sunflower Halfway Home for Boys headed by
Fr. Geraldo Costa, CICM, to the SLU Special Services Department, to the jury panel of this research
headed by ME Department Head Engr. Alfon V. Gatchallan, PME, MSME, and joined by Engr. Geneross
Padua and Engr. Dylan Deponio for their suggestions and revisions, to the ME Workshop Staff, to the CE
Department headed by Engr. Renato D. Tandoc, MSCE, to the Materials Testing and Laboratory Staff, to
the PAGASA Baguio Complex, to the SLU Libraries, to our respective families for being our inspiration,
to all fellow researchers who have continually pushed us in this use of renewable energy track of research,
and of course to the Almighty God who made this all possible with just one single breath.
13
Appendices
Actual Images of the Project
1) Installation of the PET bottle only set-up
14
Bibliography
Schoenbauer, B., Bohac, D., & Hewett, M. (2012). Measured Residential Hot Water End Use. ASHRAE
Transactions, 118(1), 872-889.
Lutz, J. D. (2014). A New Method of Near Real-Time Monitoring of Residential Hot Water Distribution
System Performance. ASHRAE Transactions, 120(2), 1-8
Thomas, M., Hayden, A. S., Ghiricociu, O., Cane, R. D., & Gagnon, R. (2011). A New Study of HotWater Use in Canada. ASHRAE Transactions, 117(1), 673-682.
Tianchi, H., Yoshino, H., & Jie, Z. (2012). Field Measurements of Residential Energy Consumption and
Indoor Thermal Environment in Six Chinese Cities. Energies (19961073), 5(6), 1927-1942.
doi:10.3390/en5061927
Gutierrez-Escolar, A., Castillo-Martinez, A., Gomez-Pulido, J. M., Gutierrez-Martinez, J., & Stapic, Z.
(2014). A New System to Estimate and Reduce Electrical Energy Consumption of Domestic Hot
Water in Spain. Energies (19961073), 7(11), 6837-6855. doi:10.3390/en7116837
Bagge, H., & Johansson, D. (2015). Variations in Use of Domestic Hot Water between Years Measurements in 539 Apartments during Six Years. ASHRAE Transactions, 121(2), 1-8.
An, Q., An, H., Wang, L., & Huang, X. (2014). Efficiency of household energy utilization in rural
China. International Journal Of Low Carbon Technologies, 9(2), 135-143.
Wei-Min, L., Kai-Chun, F., Keh-Chin, C., & Kung-Ming, C. (2013). Dissemination of Solar Water
Heaters in Taiwan: The Case of Remote Islands. Energies (19961073), 6(10), 5101-5113.
doi:10.3390/en6105101
Mureddu, M., Caldarelli, G., Chessa, A., Scala, A., & Damiano, A. (2015). Green Power Grids: How
Energy from Renewable Sources Affects Networks and Markets. Plos ONE, 10(9), 1-15.
doi:10.1371/journal.pone.0135312
Saygin, D., Kempener, R., Wagner, N., Ayuso, M., & Gielen, D. (2015). The Implications for Renewable
Energy Innovation of Doubling the Share of Renewables in the Global Energy Mix between 2010
and 2030. Energies (19961073), 8(6), 5828-5865. doi:10.3390/en8065828
Yrjl, J., & Laaksonen, E. (2015). Domestic Hot Water Production with Ground Source Heat Pump in
Apartment Buildings.Energies (19961073), 8(8), 8447-8466. doi:10.3390/en8088447
Aikins, K. A., & Choi, J. M. (2013). Issues to improve ground source heat pump units in Korea:
Refrigerant application and hot water generation. Journal Of Renewable & Sustainable
Energy, 5(5), 052002. doi:10.1063/1.4821509
Stecher, D., & Allison, K. (2012). Residential Ground Source Heat Pumps with Integrated Domestic Hot
Water Generation: Performance Results from Long-Term Monitoring. ASHRAE
Transactions, 118(1), 42-49.
Gunerhan, H. and Hepbaslia, A., 2007. Exergetic modeling and performance evaluation of solar water
heating systems for building applications. Energy and Buildings, 39 (5), 509516.
Gang, P., Guiqiang, L., Xi, Z., Jie, J., & Yuehong, S. (2012). Comparative Experimental Analysis of the
Thermal Performance of Evacuated Tube Solar Water Heater Systems With and Without a MiniCompound Parabolic Concentrating (CPC) Reflector(C < 1). Energies (19961073), 5(4), 911924. doi:10.3390/en5040911
Ma, F., Gao, W., Liu, T., Lin, W., & Li, M. (2013). An experimental study on the impacts of key
parameters of all-glass evacuated tubes on the thermal performances of all-glass evacuated tube
solar water heaters. Journal Of Renewable & Sustainable Energy, 5(2), 023140-023140-14.
doi:10.1063/1.4803527
Arunachala, U. C., Sreepathi, L. K., & Siddhartha Bhatt, M. (2014). Analytical studies on drop of H-W-B
constants due to scaling in natural circulation flat plate solar water heater. International Journal
Of Sustainable Energy, 33(1), 192-202. doi:10.1080/14786451.2012.755186
Gaidajis, G., & Angelakoglou, K. (2011). Assessment of the environmental impacts deriving from the life
cycle of a typical solar water heater. Journal Of Engineering Science & Technology Review, 4(1),
92-95.
15
Bekele, A., Alemu, D., & Mishra, M. (2013). Large-scale solar water heating systems analysis in
Ethiopia: a case study. International Journal Of Sustainable Energy, 32(4), 207-228.
doi:10.1080/14786451.2011.605951
Khan, M. A., Abdul Malek, A., Mithu, M. H., & Das, D. K. (2010). Design, fabrication and performance
evaluation of natural circulation rectangular box-type solar domestic water heating
system. International
Journal
Of
Sustainable
Energy, 29(3),
164-177.
doi:10.1080/14786461003611584
Ong, K. (2011). Experimental comparative performance testing of solar water heaters. International
Journal Of Low Carbon Technologies, 6(4), 270-276.
Jesko Z. (2008). Classification of Solar Collectors. In: Osadcuks V. (eds) Engineering for Rural
Development: 7th International Scientific Conference, Latvia University of Agriculture, Faculty
of Engineering, Jelgava, Latvia, pp. 22-27.
Yi-Mei, L., Kung-Ming, C., Keh-Chin, C., & Tsong-Sheng, L. (2012). Performance of Thermosyphon
Solar Water Heaters in Series.Energies (19961073), 5(9), 3266-3278. doi:10.3390/en5093266
Goswami, D.Y., Kreith, F., and Kreider, J.F. (2000). Solar-heating systems: principles of solar
engineering. 2nd ed. USA: Taylor & Francis, 222.
Kalogirou, S.A. (2004). Solar thermal collectors and applications. Progress in Energy and Combustion
Science, 30, 231295.
Cengel (2003). Heat Transfer: A Practical Approach. New York, NY: McGraw-Hill.
Ali Sadeghzadeh, M. (2012). Thermosiphon heat pump for pipe freeze preventing of domestic passive
solar water heater. Journal Of Renewable & Sustainable Energy, 4(5), 053102.
doi:10.1063/1.4751471
Rosado Hau, N., & Escalante Soberanis, M. A. (2011). Efficiency of a parabolic trough collector as a
water heater system in Yucatn, Mexico. Journal Of Renewable & Sustainable Energy, 3(6),
063108. doi:10.1063/1.3663954
Ho, C., Yeh, H., & Chen, T. (2012). Theoretical and Experimental Studies of the Ultra-Thin-Channel
Solar
Water
Collector. Heat
Transfer
Engineering, 33(15),
1272-1280.
doi:10.1080/01457632.2012.692301
Issam, A. (2014). A new approach to obtain Kevlar-49 from PET waste bottles. Research On Chemical
Intermediates, 40(8), 3033-3044. doi:10.1007/s11164-013-1149-5
Asiimwe, J. K., Quilty, B., Muyanja, C. K., & McGuigan, K. G. (2013). Field comparison of solar water
disinfection (SODIS) efficacy between glass and polyethylene terephalate (PET) plastic bottles
under sub-Saharan weather conditions. Journal Of Water & Health, 11(4), 729-737.
doi:10.2166/wh.2013.197
Sirocic, A. P., Fijacko, A., & Hrnjak-Murgic, Z. (2013). Chemical Recycling of Postconsumer Poly
(ethyleneterephthalate) Bottles Depolymerization Study. Chemical & Biochemical Engineering Quarterly, 27(1), 65-71.
Khalimov, A.G., Khairiddinov, B.E., Kim, V.D., and Khalimov, G.G. (2011). Thermophysical
Characteristics of Plastic Bottles as an Element of Water Heat Accumulators in Solar
Greenhouses.
Solar
Power
Plants
And
Their
Application,
48(1),
38-41.
doi:10.3103/S0003701X12010082
16