2-2009
Page 1.
Change references
1. From: ANSI/ICEA S-90-661-2006, Category 3, 5, & 5e Individually Unshielded Twisted
Pair Indoor Cables (With or Without an Overall Shield) for Use in General Purpose and
LAN Communication Wiring Systems Technical Requirements, 2006
To: Category 3, 5e, 6, and 6A horizontal cables shall comply with the mechanical
performance requirements, testing and test methods in ANSI/ICEA S 90 661 2002
2. From: In addition to the applicable requirements of ANSI/ICEA S-90-661-2006 and
ANSI/ICEA S-102-732-2009, the physical design of category 3, 5e, 6, and 6A horizontal
cables shall meet the additional requirements of this clause.
To: Category 3, 5e, 6, and 6A cord cables shall comply with the mechanical performance
requirements, testing and test methods in ANSI/ICEA S 90 661 2002
To: Category 3, 5e, 6, and 6A backbone cables shall comply with the mechanical
performance requirements, testing and test methods in ANSI/ICEA S 90 661 2002.
Page 15, Clause 5.8.1
Change references
1. From: Cables used to construct cross-connect jumpers shall meet the requirements of
clause 5.3.1 and the applicable requirements of ANSI/ICEA-S-90-661-2006.
To: Cables used to construct cross-connect jumpers shall meet the requirements of
clause 5.3.1 and the applicable requirements of ANSI/ICEA S 90 661 2002.