LUMINAIRES
600x600mm 43w IP44 LED DALI DIMMABLE
RECESSED SHALLOW MODULAR LUMINAIRE. THORN
OMEGA LED OR EQUAL AND APPROVED
A1
A2
A3
X-RAY
EX1
EX3
LIGHTING CONTROLS
EM2
EX1
EM
EX1
EM
EX1
EM
EX1
EM
EM2
EM2
EX1
EM
EM2
EM2
EM1
EM2
EM1
EM2
EM2
EM2
EM2
EM2
EM2
EM1
EM1
EX1
EM
DCU
EX1
EM
EX1
EM
EX1
EM
EX1
EM
EM1
EM
A1
A1
A1
EM
EM
EM
MG
EM
H/O/A
EM1
A1
EM1
EM1
DCU
EM
DCU
A1
EM
EM1
EM1
EM
EM1
EM1
EM
EM
A1
EM1
EM1
EM
A1
A1
EM1
A1
EM1
EM
EX3
EM
A1
EM1
A1
A1
EX3
EX3
EM
EM1
EX3
EM2
A1
EM1
EM1
A1
EM1
A1
A1
EM2
EM1
EM2
EM2
EM1
EM2
EM2
A1
LC-MP
EM1
EM2
PEC
DCU
D
A1
A1
A1
NOTE 14
NOTE 14
A1
A1
A1
A1
A1
A1
EM2
NOTE 14
EM1
A1
EM1
A1
A1
EM1
EM1
EM2
A1
A1
EM1
EM1
EM1
EM1
A1
EM1
EM1
EM1
EM1
EM2
A1
A1
A1
A1
A1
A1
A1
EM1
A1
EM1
EM1
A1
EMERGENCY FITTINGS
3W LED BLADE EXIT - ELP SLD M3
DALI OR EQUAL AND APPROVED
EX1
EM1
EM1
EM1
EM1
EM1
A1
EX2
EM1
A1
A1
EM1
A1
A1
EM1
EM2
A1
A1
EM2
EM2
EM2
EM2
EM2
EM2
EM2
EM2
EM2
A1
EM1
A1
A1
EM2
A1
A1
EM1
A1
EM1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
EM1
EM1
A1
A1
EM1
EM1
EM1
EM1
EM1
EM1
EM1
EM1
EM1
EM1
A1
EM1
A1
A1
EM1
A1
EM1
EM1
EM1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
EM1
A1
A1
A1
A1
EM1
EX1
EM
EX1
EM
National Development
Finance Agency
DATE:
DESCRIPTION:
REV:
DATE:
DESCRIPTION:
NOTES:
1. GENERAL LIGHTING INSTALLATION TO BE 3x2.5mm LSF INSULATED SOLID
COPPER CABLE FED FROM 10A MCB OR RCBO AS PER ETCI
REGULATIONS.
2. EXTERNAL FITTINGS TO BE MINIMUM IP65 AND IK08.
3. ALL LIGHTING IN PATIENT CARE AREAS, CORRIDORS, OFFICES AND
CIRCULATION SPACES TO BE DIMMABLE.
4. ALL SWITCHES TO BE RATED FOR 20A INDUCTIVE OR RESISTIVE LOADS.
5. PILOT LIGHTS ON SWITCH PLATES TO BE FITTED WITH NEON LAMP,
LIMITING RESISTOR AND RED LENS.
6. SWITCHES TO BE MOUNTED AT 1100mm CENTERS ABOVE FINISHED
FLOOR LEVEL UNLESS LOCAL REQUIREMENTS DICTATE OTHERWISE.
7. ALL FITTING TO BE IP44, CE MARKED AND ON THE SEAI TRIPLE E
REGISTER.
8. EXTERNAL FITTINGS NOT TO BE WIRED ON THE SAME CIRCUITS AS
INTERNAL FITTINGS.
9. EXTERNAL LIGHTING TO HAVE RCBO PROTECTION IF LOCATED AT LESS
THAN 2.8m AFFL.
10. CONTRACTOR TO SATISFY THEMSELVES THAT FINISHED LIGHTING
INSTALLATION WILL MEET THE REQUIREMENTS OF SLL LIGHTING GUIDE
2012, LIGHTING GUIDE 2 2008, LIGHTING GUIDE 5 2011 AND SPECIFIC HTM
& HSE REQUIREMENTS, & ALSO IS3217-2013 WHERE APPLICABLE.
11. EXTERNAL LIGHTING TO HAVE PHOTOCELL, H/O/A AND DALI LIGHTING
SYSTEM CONTROL.
12. MASTER LIGHTING CONTROL TO BE A DALI LIGHTING CONTROL NETWORK
ALLOWING CONTROL, MONITORING AND TESTING FOR ALL AREAS WITH
PC IN MAIN RECEPTION.
13. LOCAL CONTROL TO CONSIST OF:
PIR WITH SWITCH OVERRIDE IN STORES AND OFFICES
PIR WITH MANUAL OFF SWITCHING IN CLINICAL ROOMS
PIR WITH TIME DELAY IN TOILET/SHOWER AND CONTAMINATION AREAS
14. SPECIFIC TASK LIGHTING TO BE PROVIDED FOR AS NECESSARY AND
CO-ORDINATED WITH FURNITURE LAYOUTS.
15. LIGHTING TO BE ATEX RATED IN AREAS WITH GASES.
16. LIGHTING IN COMMS ROOMS TO BE CO-ORDINATED WITH HIGH LEVEL
CONTAINMENT AND CABINET LAYOUT.
17. ROOFTOP LIGHTING TO BE CONFIGURED TO PROVIDE PATHWAY
LIGHTING FOR MAINTENANCE ACCESS TO PLANT AND EQUIPMENT.
18. LIGHTING CIRCUITS ARE INDICATIVE ONLY AND ARE SUBJECT TO ON SITE
CO-ORDINATION AND SPECIFICATION OF LIGHTING CONTROL SYSTEM.
19. SEE DRAWING PCC-WAT-ME-PBB-DR-0200 FOR EXTERNAL LIGHTING
DETAILS.
20. ALLOW FOR INTERMEDIATE LCM OUTSTATIONS AS PER SYSTEM
REQUIREMENTS.
21. NO MORE THAN 8No LIGHT FITTINGS TO BE INSTALLED PER CIRCUIT.
22. WHERE MORE THAN ONE LUMINAIRE IS TO BE PROVIDED IN A ROOM, A
MINIMUM OF TWO SWITCHES SHALL BE PROVIDED.
DRAWING TITLE:
DRAWING NUMBER:
PCC:
SCALE:
REVISION:
STATUS:
SHEET SIZE: