The next edition of this Standard is scheduled for publication in 2008. There will be no addenda
issued to this edition.
ASME issues written replies to inquiries concerning interpretations of technical aspects of this
Standard. Interpretations are published on the ASME Web site under the Committee Pages at http:/ /
www.asme.org/codes as they are issued, and will also be published within the next edition.
This code or standard was developed under procedures accredited as meeting the criteria for American National
Standards. The Standards Committee that approved the code or standard was balanced to assure that individuals from
competent and concerned interests have had an opportunity to participate. The proposed code or standard was made
available for public review and comment that provides an opportunity for additional public input from industry, academia,
regulatory agencies, and the pUblic-at-large.
ASME does not "approve," "rate," or "endorse" any item, construction, proprietary device, or activity.
ASME does not take any position with respect to the validity of any patent rights asserted in connection with any
items mentioned in this document, and does not undertake to insure anyone utilizing a standard against liability for
infringement of any applicable letters patent, nor assume any such liability. Users of a code or standard are expressly
advised that determination of the validity of any such patent rights, and the risk of infringement of such rights, is
entirely their own responsibility.
Participation by a federal agency representative(s) or person(s) affiliated with industry is not to be interpreted as
government or industry endorsement of this code or standard.
ASME accepts responsibility for only those interpretations of this document issued in accordance with the established
ASME procedures and policies, which preclude the issuance of interpretations by individuals.
Copyright 2004 by
THE AMERICAN SOCIETY OF MECHANICAL ENGINEERS
All rights reserved
Printed in U.s.A.
CONTENTS
Forevvord ........................................................................
iv
vi
vii
Summary of Changes
1
References
Definitions
General Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
13
19
19
20
Figures
1 Typical Floor Openings [for 14 in. (355 mm) Belts] . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 Guardrail and Wall. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3 Guardrail or Screened Enclosure .................... . . . . . . . . . . . . . . . . . . . . . . . . . .
4 Fixed Type Underfloor Hoods and Guardrail. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5 Maze Entrance to Manlift . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6 Typical Pit Location Detail (for New Installations) ........................... . .
7 Typical Lower Landing Detail. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8 Head Shaft Dimensions - Top Landing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9 Distance Betv,Teen Handhold and Step. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
10 Typical Butt Splice Detail. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
11 Typical Lap Splice Detail. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
12 Typical Manual Splice Detail. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3
4
5
6
7
9
10
11
12
15
16
17
Tables
1 Allowable Size for Floor Openings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 Rubber Manufacturers Association Tolerances for Width of Belting ......... " ..
3 Belt Breaking Strengtll.................. .......... ............................
4 Minimum Number of Bolts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2
13
14
18
Mandatory Appendices
I Recommended Training Program for Manlift Passengers. . . . . . . . . . . . . . . . . . . . . . .
II Belt Manlift Inspection Report (Weekly and Monthly). . . . . . . . . . . . . . . . . . . . . . . . . .
23
24
iii
Copyright 2004 by the American Society of Mechanical Engineers.
No reproduction may be made of this material vvithout written consent of ASME.
FOREWORD
This is a revision of A90.1, Safety Code for Manlifts, which was originally drawn up and
approved in 1949 and reaffirmed in 1956. The original Sectional Committee consisted of 19
members representing manufacturers, users, insurance groups, enforcement officials, and independent specialists.
Work was started in 1966 on a revision of this Standard. Each provision of the original code
was carefully evaluated in the light of considerable practical field experience. A draft revision
was completed in 1967 and approved by letter ballot in 1968. The USA Standards Institute (now
called the American National Standards Institute, Inc.) approved the revised standard on February
7, 1969.
Prompted by several serious manlift accidents, the Committee, through correspondence in
1970, considered additional changes to the 1969 standard. Subsequently, in 1972, the Committee
issued ANSI A90.1a-1972, a supplement to ANSI Standard A90.1-1969.
In 1972, new Committee officers were appointed and Committee membership was expanded
to include new members, many of whom have since made significant contributions to the work
of the A90 Committee.
Due to changes in technology and the desire to maximize manlift safety, the Committee set
about the task of totally revising the A90.1 Standard. This was accomplished only with a great
deal of individual member research and study, coupled with numerous meetings of the entire
committee. After three years of concentrated work, the Committee approved by ballot, in 1976,
a completely revised draft of the A90.1 Standard. Subsequently, this draft was approved by
the American National Standards Institute, Inc., for issuance as American National Standard
A90.1-1976.
In 1981, the A90 Committee was converted from an American National Standards Committee
to an ASME Accredited Organization Committee, operating under procedures developed by the
ASME and accredited by ANSI. Several new members were added to the Committee in this
process. After several years of work, a revision to ANSI A90.1-1976 was approved by the A90
Committee and the sponsor organization, and was designated an American National Standard
by the American National Standards Institute, Inc., on September 10, 1985.
This revision was approved by the American National Standards Institute on August 14, 2003.
IV
OFFICERS
M. W. Basnight, Chair
Secretary
COMMIITEE PERSONNEL
l. R. Barnes, Barnesco, Inc.
Z. C. Barnes, Alternate, Barnesco, Inc.
M. W. Basnight, International Paper
C. E. Jackson, Alternate, International Paper
S. V. Buchanan, Rubber Belting and Hose
B. l. Bursiek. American Feed Industry Association
G. l. Cole, Industrial Erectors, Inc.
B. R. Cole, Alternate, Industrial Erectors, Inc.
J. M. Favro, Humphrey Manlift Co., Inc.
D. D. FrazeUe, Archer Daniels Midland
G. J. Hauber, PermaTron Elevator, Inc.
D. l. johnson, Consultant
W. E. Phillips, Jr., CNA
D. l. Weinhold, Central Soya Co., Inc.
J. D. Wendler, The American Society of Mechanical Engineers
v
Copyright 2004 by the American Society of Mechanical Engineers.
No reproduction may be made of this material without written consent of ASME.
-----_...
._--_.....-
Subject:
Edition:
Question:
Requests that are not in this format may be rewritten in the appropriate format by the
Committee prior to being answered, which may inadvertently change the intent of the
original request.
ASME procedures provide for reconsideration of any interpretation when or if additional
information vvhich might affect an interpretation is available. Further, persons aggrieved
by an interpretation may appeal to the cognizant ASME committee or subcommittee. AS:l\1E
does not "approve," "certify," "rate/' or "endorse" any item, construction, proprietary
device, or activity.
Attending Committee Meetings. The A90 Standards Committee regularly holds meetings that are open to the public. Persons wishing to attend any meeting should contact
the Secretary of the A90 Standards Committee.
vi
Copyright 2004 by the American Society of Mechanical Engineers.
No reproduction may be made of this material without written consent of ASME.
Location
Change
1.5
Added
Table 1
4.1.1
Revised
4.6.1
Note added
13,14
5.1.2(b)
Revised
5.2.4
5.2.5
Revised
17
Fig. 12
Added
18
5.5.9
Added
5.6.5
Revised
5.7.2
8.1.10
Added
20
vii
Copyright 2004 by the American Society of Mechallical Engineers.
No reproduc!.i?l1 may be
of this
vvithout
consent
A_SIvlE
_ _.
mad~
mateI!.~
wri~en
.C?~_.
~)
_~V
viii
Cop)Tight 2004 by the American Society of Mechanical Engineers.
No reproduction may be made of this material ",ithout written consent of ASME.
--.----
----
..
._----
ASME A90.1-2003
GENERAL
1.1 Scope
This Standard applies to the manufacture, installation,
maintenance, inspection, and operation of manlifts.
Manlifts covered by this scope consist of steps (platforms) and accompanying handholds mounted on, or
attached to, an endless belt operating vertically in one
direction only and being supported by, and driven
through, pulleys at the top and bottom. These manlifts
are intended for conveyance of persons only. It is not
intended that this scope cover moving stairways, elevators with enclosed platforms (Paternoster elevators),
gravity lifts, or conveyors used only for conveying materials.
REFERENCES
1.2 Purpose
The purpose of this Standard is to establish safety
requirements for manlifts. It is intended for use as a
standard reference for manlift safety requirements by
manufacturers, architects, plant designers, installers,
and consulting engineers, and for users of manlifts
through voluntary application and for governmental
authorities.
1.3 Application
(a) This Standard applies to manlifts used to carry
only authorized personnel trained in their use. Manlifts
shall not be avaHable to the general public.
(b) Because of the difficulty in enforcing paras. 4.2
and 7.1(a), manlifts are not recommended for use on
construction sites.
(c) One year after the date of issuance, all provisions
of this Standard shall apply to both new and existing
installations, except as noted in individual sections.
DEFINITIONS
1.4 Exceptions
In case of practical difficulty or unnecessary hardship,
the enforcing authority may grant exceptions from the
literal requirements of this Standard or permit the use
of alternate methods, but only when it is clearly evident
that equal safety is thereby secured.
-------------.--.- ..
-.~
..- .
(03)
...
"'
ASME A90.12003
(03)
in. (mm)
Minimum Floor
Opening Width,
in. (mm)
Maximum Floor
Opening Width.
in. (mm)
12 (305)
14 (355)
16 (405)
28 (710)
30 (760)
30 (760)
36 (915)
38 (965)
40 (1 015)
Belt Width,
4.3.2 Clear Landing Space. The landing space adjacent to the floor openings shall be free from obstruction
and kept clear at all times. The landing space shall be
at least 2 ft (610 mm) in width from the edge of the floor
opening used for mounting and dismounting (see Figs.
2 and 3).
GENERAL REQUIREMENTS
4.1.2 Uniformity. All floor openings for a given manlift shall be uniform in size and shall be approximately
circulal~ and each shall be located vertically above the
opening belmv it.
4.2 Riding Clearance
(a) There shall be no encroachment of any kind within
the cylindrical space defined by the outer edges of the
2
Copyright 2004 by the American Society of Mechanical Engineers.
No reproduction may be made of this material ...'vithout "",ritten consent of ASME.
ASME A90.1-2003
38 in.
34 in.
(865 mm) min.
24 in.
Faceoft
belt
28 in.
Up
~
Down
-;::::::::::-1
-------------------....~
I
I
I
/
Fig. 1
1+---24~in.
(610 mm) min.
28 in.
I
I
I
.1
CopYTight
2004 by the Arrlerican Society of Mechanical Engineel's.
No repwduction may be made of this material ,\/ithout written consent of ASME.
ASME A90.1-2003
................................................................ .
,o
~
Fig. 2
4
~.?
..
:s
~
"'.,
ASME A90.1-2003
.. .. .. .. ..
.................................................................................................................
. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. . .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
.. .. .. ..
..
..
..
..
1+--"+-- If 24 in. (610 mm) or more, guardrail is 42 in. (1065 mm) min.
~-~--If
less than 24 in. (610 mm), guardrail is 66 in. (1675 mm) min.
Fig. 3
..
-. ...
..
--~
".s
ASME A90.1-2003
0
, ,~' '~~j
o'~"0
~
P' ,~' c>"o
:,~oOd
o'c>'
0, '
45degrnin~
~o' 0 ,
:o',~:O'
0,
,o,~%
0,'
,c:, ,
,0'
'0"
0.
18 gage (min.)
--'
.,/
~,
Down
Up
7 ft 6 in
(2285 mm) min.
1- -::::::::::::::::::::::::;~
1
I
1
I
1
I
1
I
1
I
I
I
1
I
I
I
::-.
~;::.:.:.:.:.:.:::.:.
42 in.
(1065 mm)
!I
,O~o,
,0'
0,
0,
'0'
, 0
K'
1
0,
r,openi
=:~ooJ
'~,o'o
, , 0 ' '0"
"
P'~
Q"c>'O',
,o,~Z
'
,,0'
I-
fig. 4
4.5.2 Construction. The rails shall be standard guardrails with toeboards meeting the provisions of ANSI
A12.1. On those sides not used as a landing, the guardrails shall be extended to a minimum height of 66 in.
(1 675 mm) when less than 24 in. (610 mm) away from
the edge of the floor opening. In lieu of the 66 in. (1 675
mm) high guardrajJ, a wall, wire mesh, expanded metal,
or solid panels may be used. This minimum 66 in. (1 675
mm) high guardrail is intended to prevent personnel
alongside the manlift from being able to lean over the
-'_.
C
I
I
I
I
I
I
I
I
.....
,O'~j
'
0,'
I
I
I
I
I
I
I
I
'\
}"
,.
ASME A90.1-2003
....................................................................................................................
................................................................................................
..
L
I
-~-
EmergencvL
ladder
---------~-------
Guardrails
near edge of
opening to
approx. of
floor opening
Standard
guardrails
<t
opening
24 in. (610 mm) min .
...........................................................................................................................
.. . . . . . . .. . . .
. . .. . .. . . . . .. .. .. . .. . . . . . . .. . .. .. . . . .
. . .. .. . . .. . .. . . .. . .. . . . .. .. . . . . . . .. . .. .. .. . . . . . .. . .. ..
..
..
..
..
..
..
..
GENERAL NOTE: Entry shown on two sides; entry on one side is adequate.
Fig. 5
7
CopYlight 2004 by the American Society of Mechanical Engineers.
No reproduction may be made ofthis material without ,"witten consent of ASME.
ASME A90.12003
4.10 Illumination
4.10.1 General. Both runs of the manlift shall be illuminated at all times when the lift is in operation. An
intensity of not less than 1 fc (10.7 Ix) shall be maintained
at all points. (Howevel~ see para. 4.3.3 for illumination
requirements at landings.)
8
Copyright 1004 by the American Society of Mechanical Engineers.
No reproduction may be made of this material \'\Tithout \'vritten consent of ASME.
ASME A90.1-2003
Belt
Down
1 in.
(25 mm)
Up
min.
Split rail
safety stop
(see paras. 4.6.2
and 5.7.2)
4ft 6 in.
(1065 mm)
min.
safety stop
3ft
----- (0.91 m)
min.
5ft
(1.52 m)
min.
9
Copyright 2004 by the American Society of Mechanica1 Engineers.
No reproduction may be made of this material without -vvrittell consent of ASME.
V1
$:
I"f'I
\C)
;...
N
Up
o
o
w
Down
zo
.g
a.
''!]
-.
_ crq
()
,.... ::l"
~ @
<~ ~
0'0
(1)
..,.
0'
Standard
guardrail
~'-<
-g
~?
~9
_. (1)
til
:::
::l.
a
I ......
~
()
r:/l
,.... 0
e:.,o
~.$
S'o
o ,...,
a~
:s::
(1)
"'l
()
~.
....
8 e.
::: :::
tT1
U'l
eg u.9.
~
,...,(1)
?iii
I./J
4 ft. 6 in.
(1065 mml
4 ft. 6 in.
(1065 mm)
min.
min.
Treadle
safety
stop
e
S.!Q
'.IJ
V1
Sl
V1
);!
Z
;::tI
.."
;::tI
OJ
I'T1
GENERAL NOTE: Refer to paras. 4.5 and 4.6.4 for guardrail arrangement on down side.
!:i
.~
$:
fig. 7
ASME A90.1-2003
5ft
(1.5 m)
min.
~~------j--I
Headshafi-\op pulley
11 ft
(3.4 m)
min.
Down
Up
6ft
(1.8 m)
min.
'-r--__-___-_-_-_-_-_-_-_,7
II
I I
I I
~-------------I
------------
I
I
I
I
I I
I
I
I
I
I
fig. 8
11
Copyrig-ilt--c-2-0-0-4-b-y-tl-)e-A-n-le-r-ic-a-n-S-o~ie-tv-~-o-f-M-ec-ha-ni~al Engineers~
No reproduction may be rnade of this material without writte.l1 consent of ASME.
ASME A90.1-2003
..,
rf
~(
,0'
~'
0c1
a,'ao"o:'\::,
00;
~o,O~
IO'~O'
'no"o:'\::,'
o'o:'\::,
/
t
1
1[7
Down
I1
~Ladder
Up
rungs
:1
4ft 8 in.
(1420 mm)
max.
4ft
(1200 mm)
min.
/
"
1----------;:
_ _ _ _ _ _ _ _ ..i
I
I
I
I I
I
I~
:;...-___-_____-_-___-I
I
I 1
I I
I I
I I
I I
I
I I
I I
I
Jropenin
..J
I....
P.,,~O'o'\::,:
,o'~o
o~
r'o,~o o~
~~o
'n'o
''\::,'
t-
Fig. 9
12
CopyTight 2004 by the American Society of Mechanical Engineers,
No reproduction may be made ofthis material ,vithout wTItten consent of ASME,
ASME A90.1-2003
Table 2
Plus or Minus
in.
in.
Type of Belting
(All Belt Widths)
Fraction
Molded edge
Slit edge
Decimal
mm
Fraction
Decimal
mm
0.250
0.125
6.35
3.17
1;
0.250
0.125
6.35
3.17
MECHANICAL REQUIREMENTS
5.1 Machines
5.1.1 Types. Machines shall be the direct-connected
type. Cast-iron gears shall not be used. There shall be
no 90 deg shoulders machined onto any shaft in manlift
machines or pulleys.
EXCEPTION: Existing multiple V-belt drive systems are permissible. All new installations shall be the direct-connected type. When
one V-belt is replaced, all belts shall be replaced.
5.1.2 Brake
(a) A mechanically applied, electrically released brake
(03)
14
5.2 Belt
5.2.1 Material. The material shall be laminated belting, solid-woven PVC belting, or other belting meeting
the strength requirements of para. 5.2.3.It shall have a
coefficient of friction such that when used in conjunction
with an adequate tension device, it will meet the brake
test specified in para. 5.1.2.
5.2.2 Width. Belts shall meet Rubber Manufacturers
Association (RMA) tolerances for width. The minimum
tolerances shall be as follows (see Table 2).
(a) New Installations. The width of the belt shall be
not less than 14 in. (355 mm) for a travel not exceeding
150 ft (46 m)1 and 16 in. (405 mm) for a travel exceeding
150 ft (46 m) for new manlift installations.
(b) Existing Installations. The width of the belt may be
less than those dimensions specified in para. 5.2.2(a),
but never less than 12 in. (305 mm) nor less than that
NOTE: When replacing old belts with new belts meeting tensile
strength requirements for 12 in. (305 mm) and 14 in. (355 mm)
manlift belts exceeding maximum height limitations, belts with
lap or butt splices, due to increased thickness, may lose flexibility
at the splice when passing over the top pulley. The resulting stress
on the splice may cause a premature elongation of bolt holes and
fracture or tearing of the belt. It is recommended that this potential
problem be reviewed with the belt supplier prior to installation.
Further, it is recommended that more frequent checks be made
during the first few months of operation to detect if sHch conditions
are developing.
13
Copyright 2004 by the American Society of Mechanical Engineers.
No reproduction may be made of this material without \vritten consent of ASME.
(03)
ASME A90.12003
Table 3
Belt Travel
Pulley Centers
ft
(03)
Belt Width
m
Minimum Belt
Breaking Strength
of Belt Width
Minimum Belt
Breaking Strength
per Full Belt Width
in.
mm
Ib/in.
N/mm
Ib
0-100
0-30
12
14
16
305
355
405
2,550
2,250
2,000
445
395
350
30,600
31,500
32,000
136100
140 100
142300
100-150
30-46
12
14
16
305
355
405
3,675
3,200
2.850
645
560
500
44,100
44,800
45,600
196200
199300
202 800
150-250
46-76
12
14
16
305
355
405
6,000
5,225
4,625
1 050
915
810
72,000
73,150
74,000
320300
325 400
329 200
5.2.7 Elevator Bolts. All elevator bolts used for joining the belt or securing handholds or steps to the belt
shall be installed and maintained so that the heads do
not project beyond the inner surface of the belt (see
Table 4).
5.4 Speed
5.4.1 Maximum Speed. No manlift with a belt speed
in excess of 80 ft/min (0.4 m/sec) shall be installed.
5.3 Pulleys
14
Cop)Tight 2004 by the American Society of Mechanical Engineers.
No reproduction may be made ofHris material without \\Titten consent of ASME.
ASME A90.1-2003
L
~
I
-f
6 ft min. for
pulley centers
upto 100ft,
8 ft min. for
pulley centers
over 100 ft
---------.
Metric Conversion
5A6 in.
7.9 mm
1%in.= 40mm
12 in. = 305 mm
14 in. = 355 mm
16 in. = 405 mm
6 ft = 1.8 m
8 ft = 2.4 m
100 ft = 30 m
16 in. Belt
40
46
54
5/16
Fig. 10
1-"
~---------.
'-'
ASME A90.1-2003
1
L
HV
V--
Elevator bolt
3 ft min. for
pu lIey centers
up to 100 ft,
4 ft min. for
pulley centers
over 100 ft
----------
Metric Conversion
3 ft = 0.9 m
4 ft = 1.2 m
100 ft = 30 m
5;16 in. =
7.9 mm
l\~in.= 40 mm
12 in.
305 mm
14 in.
355 mm
16 in. = 405 mm
12 in. Belt
16 in. Belt
20
23
27
Minimum bolt size of 5;16 in. with lock nut or lock washer backed
with flat washer
fig. 11
16
Copyright 2004 by the American Society of Mechanical Engineers.
No reproduction may be made of this matelial without written consent of ASME.
ASME A90.1-2003
12 (305)
14 (355)
16 (406)
Minimum Grade 5,
7
8
Fig. 12
(03)
ASME A90.1-2003
Table 4
Width of Belt
Type of Splice
in.
mm
Minimum Number
of Bolts
Butt
12
305
355
405
305
355
405
40
46
54
20
23
27
14
Lap
16
12
14
16
directly, they shall be of the multiple type, i.e., all conductors entering the switch must be opened.
(b) Where electronic devices are used, they shall be
so designed and installed that failure will result in cutting off the power to the drive motor.
(c) All electrical installations shall be classified in
accordance with the requirements of NFPA 70-1984.
lR
Copyright 2004 by the American Society of Mechanical Engineers.
No reproduction may be made ofthismaterial "ithont v'iTitten consent of ASME.
ASME A90.1-2003
NOTE: It is recommended that all electrical motor control apparatus and safety relays be placed in a locked enclosure so as to
prevent tampering by unauthorized persons.
TOP FLOOR -
GET OFF
The sign shall be in block letters not less than 2 in. (50
mm) in height and shall be located within easy view of
an ascending passengel~ not more than 2 ft (610 mm)
below the top landing.
5.8.2 Operation. This control rope shall be so connected to a control lever or operating mechanism that
it will cut off the electric power and apply the brake
when pulled in the direction of travel. When pulled in
the opposite direction of travel, the power will be
restored and the brake released, without having to reset
motor controls.
GET OPF
The sign shall be in block letters not less than 2 in. (50
mm) in height.
NOTE: It may be useful to have all floors and landings numbered
or identified by name to eliminate confusion by riders.
The sign shall be of block letters not less than 2 in. (50
mm) in height and shall be a color offering high contrast
with the background color.
NOTE: See para. 1.3(a) for definition of authorized personnel.
OPERATING RULES
------'
ASME A90.1-2003
the safety stop. Each safety stop shall be tested individually. All other safety stops shall be manually tested.
8.1.6 Start/Stop Control Rope. The manlift shall be
started and stopped on both the up- and down-runs by
means of the start! stop control rope.
8.1.7 Movable Cone Guards. If such guards are
installed, each one shall be tested by applying a force
of not more than 2 lb (9 N) on the edge of guard nearest
the hinge.
8.1.8 Speed Tests. Speed tests shall be taken and
checked against specified (rated) speed. The rated speed
shall not be exceeded by more than 10'10 when the manlift is running empty.
NOTE: Speed may be determined by a revolution counter on the
top (head) pulley, where the revolutions per minute are multiplied
by 0, where 0 is the diameter in feet, or may be determined with
a tachometer with a 6 in. (150 mm) or 12 in. (305 mm) circumference
wheel nmning in contact with the belt. l{eadings taken with a 6
in. (150 mm) 'wheel circumference should be divided by 2. For
speed values in meters per second, the follcnving conversion factor
may be useful:
8.1.3 Loaded Step Deflection. Each step shall be subjected to a 400 lb (180 kg mass) load applied to its center
while the machine is stationary. The guide rails shall not
be displaced and there shall be no visible deformation,
deflection, or misalignment of the step or its support
during the test.
8.1.4 Strength of Handhold. Each handhold shall support a load of 300 Ib (135 kg mass) without appreciable
deformation or injury to its fastenings. The test shall be
performed while the machine is stationary.
8.1.5 Safety Stops. The split-rail safety stops or intrack equivalent safety stops shall be tested by placing
a weight of 50 Ib (25 kg) on the approximate center of
the step or platform and running the manlift in
the appropriate direction until the manlift is stopped by
20
__
(03)
ASME A90.1-2003
guardrails
hoods
(0) handhold and handhold fastenings
(p) illumination
(q) lubrication
(1') motor
(s) motor coupling
(t) pulley lagging
(11) puney supports
Cv) rollers and slides
(w) safety stops
(x) skip on up- or down-run when mounting step
(check drive train)
(y) start/stop control rope
(z) steps
(aa) step clearance at top and bottom landings
(m)
(n)
(cc)
top pulley
8.2.3 Unsafe Use. The individual making the inspection shall also make a special point to observe which
persons are using the manlift and whether they are complying with the operating rules listed in para. 7. The
inspecting individual shall immediately report any
unsafe acts or unauthorized use to proper personnel.
8.2.4 Inspection log. A written inspection log shall
be kept of findings at each inspection and be signed and
dated. Records of inspection shall be made available to
duly authorized agencies. See Mandatory Appendix II
for a sample inspection form.
21
--
----
----
materi~
writt:~n
o~
22
Copyright 2004 by the Anlerican Society of Mechanical Engineers.
No reproduction may be made of this material without 'I;vritten consent of ASME.
'"
~
t:.S
m<>
ASME A90.1-2003
MANDATORY APPENDIX I
RECOMMENDED TRAINING PROGRAM FOR MANLIFT
PASSENGERS
1-1
1-3
lECTURE
1-2
DEMONSTRATION
PRACTICE
Copyright
2004 by the American Society of Mechanical Engineers.
No reproduction may be made of this material v"ithout vvritten consent of ASME.
~~
..
ASME A90.1-2003
MANDATORY APPENDIX II
BELT MANLIFT INSPECTION REPORT (WEEKLY AND MONTHLy)
Date
Code
Period
Period
Weekly
Monthly
Weekly
Monthly
3. Handholds
4. Belt Splice
22.
24. Motor
(if applicable)
structure
lights
lubricant
Date: