Beruflich Dokumente
Kultur Dokumente
4F
ATLANTIC
BOILERS
RANGE
10kW to 625kW
ENERGY RATING A
90% and above A
86% - 90%
82% - 86%
78% - 82%
74% - 78%
70% - 74%
Below 70%
A
B
C
D
E
F
G
tested
CE-0645 BL105
HEATING FLOW
& RETURN
BURNER
MAIN HEAT
EXCHANGER
FRESH AIR
CONDENSING
EXCHANGER
FLUE GASES
TREATED
CONDENSATE
IN-BUILT FEATURES
Constant temperature
requirements are achieved with
boiler controller, shunt pump,
4-port valve and flow sensor.
Minimum flow and minimum
temperature requirements are
achieved with boiler controller,
pump, 4-port valve and sensor.
Variable temperature
requirements are achieved with
boiler controller, shunt pump,
4-port valve, outside sensor and
flow sensor.
Model
Maximum Output
kW
Standard Minimum Output kW
Full load efficiency
Ambient air 22C
Oil % gcv
Gas % gcv
Fuel used
Oil ltrs/Hr
Gas m/Hr
Exit Flue gases@30C
Oil m/hr
Gas m/hr
Dry weight
kg
Water contents
ltrs
Min water pressure
BARS
Standard water pressure BARS
Max (on order)
BARS
17
17
10
22
22
15
40
40
12
60
60
20
90
90
33
93.5
90.6
1.7
1.7
23
25
125
36
0.5
3.0
7.0
95.0
92.2
2.2
2.0
30
34
200
36
0.5
3.0
7.0
95.3
92.9
4.0
4.0
55
61
300
75
0.5
3.0
7.0
94.7
91.9
7.2
6.0
82
92
438
80
0.5
3.0
7.0
DIMENSIONS
Model
Height
Width
Depth
Height-demountable
Width-demountable
Depth-demountable
Access front
Access one side
Access other side
Access rear
Access top
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
17
1165
350
940
600
410
645
500
100
500
300
300
22
1365
445
1000
750
445
680
500
100
500
300
300
40
1510
545
1220
895
545
760
500
100
500
300
300
CONNECTIONS
Model
Fresh air inlet
Warm air burner inlet
Fresh gas outlet
Heating flow
Heating return
Hot water primaries
Condensate
mm
mm
mm
mm
mm
mm
mm
17
75
50
75
25
25
25
50
22
75
50
75
25
25
25
50
40
75
50
75
25
25
25
50
SPECIFICATION
150
150
40
200
210
42
300
315
80
400
370
80
500
485
80
600
625
150
93.2
90.4
9.1
9.6
124
138
794
197
0.5
3.0
7.0
96.6 94.0
93.7 91.2
14.9 26.0
15.0 19.8
206 274
230 306
996 1014
330 500
0.5
0.5
3.0 3.0
7.0
7.0
95.3
92.4
31.0
30.0
411
460
1790
910
0.5
3.0
7.0
92.5
89.7
45.7
46.3
547
613
1975
1010
0.5
3.0
7.0
94.5
91.7
52.6
53.1
684
767
2100
1110
0.5
3.0
7.0
94.4
91.6
69.5
63.5
893
920
2225
1475
0.5
3.0
7.0
60
1645
550
1330
985
550
784
700
100
500
300
300
90
1740
740
1750
965
740
1130
1000
100
500
300
300
150
1945
885
2030
1070
885
1255
1000
100
500
300
300
200
1985
1225
3140
1281
1225
1340
1000
100
500
300
500
300
2070
1225
3770
1370
1225
1970
1000
100
500
300
500
60
75
70
75
25
25
25
50
90
110
100
110
40
40
32
50
150
110
100
125
50
50
40
50
200
125
125
200
65
65
50
50
300
125
125
200
65
65
50
50
400
150
150
200
80
80
50
50
500
150
150
200
80
80
50
50
600
200
200
200
100
100
50
50
APPLICATIONS
Airport terminals
Ambulance and Fire Stations
Art Galleries and Museums
Banks and Shops
Boarding Schools
Business Centres
Childrens/Nursing Homes
Churches and Cathedrals
Colleges and Universities
Country Houses
Day Nurseries
Department Stores
Factories
Greenhouses and
Botanical Gardens
Halls of Residence
Hospitals
Hotels and Motels
Housing Developments
Leisure Centres
Libraries
Listed Buildings
Motorway Services
Office Buildings
Police Stations
Postal Sorting Offices
Prisons
Residential Hostels
Residential Nursing Homes
Shopping Malls
Sports Clubs
Swimming Pools
Theatres
Warehouses
ISOMETRIC DRAWING
Temperature circuit,
flow and return
Main heat
exchanger
Boiler shunt pump
Condensing
exchanger
High Peak
Housing,
Derbyshire
2 - R22-150kW
natural gas
condensing boilers
Fan assembly
Glencanisp Lodge,
Scotland
1 - R22-90kW
kerosene condensing
boiler
PIPEWORK ARRANGEMENTS
Each boiler has its own header with in-built 4-port valve and shunt pump. This guarantees
minimum water flow and temperature control. Single and group boilers can use a
balancing & sedimentation vessel or a low velocity header as a neutral heat outlet.Any
number of circuits, in order of priority, can then be served adequately from the boiler(s)
Domestic Hot
Water Priority
DHW
BALANCING VESSEL
PHE
DHW
PHE
Constant
Temperature
Variable
Temperature
Boiler straight
connector
Flexible tube
Jubilee tube
Socket
Viton Seal
Drain
Boiler 135
connector
FLEXIBLE
CONNECTOR
Drain
90 connector connector
Flue gases
Flue gas
effluent
Fresh air
360 inlet
FLAT OR
PITCHED
ROOF
Fresh air
Warmed
air inlet
to boiler
Flue gases
from boiler
In addition, the ATLANTIC R Series boilers have variable speed flue gas extract fans which permit
extensive vertical and horizontal flue ducts in carefully chosen TECHNAFLON condensing flues. The flues
are graded to the boiler(s) to allow the condensate to drain to the tank in the base of each boiler. The
condensate is then treated using limestone marbles before flowing out to a normal drain.
TECHNAFLON condensing flues are precision-made from polyvinylidene fluoride (PVDF) which is
extremely corrosion-resistant, hard wearing and not effected by ultra-violet radiation. The flues are
installed without insulation. The flue gases cool rapidly, releasing the heat to the building and increasing
the plant efficiency.
ABOUT
ATLANTIC
V
W
I
D
BSV116
ATLANTIC BOILERS was formed in 1980 to promote highly efficient boilerplant and within two
years had supplied the first commercial gas condensing boilers in the United Kingdom. For
30 years, ATLANTIC BOILERS has supplied both gas and oil condensing boilers to many
Universities, Hotels, Hospitals, Medical and Social Care Buildings, Leisure Centres, Schools,
Offices and Housing Developments plus many other types of buildings. ATLANTIC BOILERS
also supplies condensing and highly efficient domestic hot water generation, based on
stainless steel manufacture.
Coupled with the supply, ATLANTIC BOILERS provides back-up commissioning, spares and
servicing by way of a network of merchants throughout the United Kingdom.
ATLANTIC
BOILERS
HIGH EFFICIENCY CONDENSING BOILER-PLANT
ADDRESS: ATLANTIC BOILERS, PO BOX 11, ASHTON UNDER LYNE, OL6 7TR
WEB: WWW.ATLANTICBOILERS.COM EMAIL: INFO@ATLANTICBOILERS.COM
TEL: 0161 621 5960 FAX: 0161 621 5966
ATLANTIC 2000 - boilerplant sales ACM ATLANTIC - commissioning and maintenance ATLANTIC 4422 - spares