Sie sind auf Seite 1von 32

TOTALLY ENCLOSED FAN COOLED INDUCTION MOTORS OF GENERAL USE ASU TYPE

The enclosed induction motor of general use range is meant for industrial application such as driving of machine tools, pumps,
fans, compressors a.s.o
The motors are intended to operate under the following environmental conditions:
- Temperature: - 330 C.........+ 400 C
0
- Relative humidity: max. 80% la 20 C
- Maximum altitude of installation: 1000 m (3000 feet)
(above sea level).
The motors are manufactured in accordance with the requirements of the following national standards:
-SR EN 60034-1 Rotating electrical machines. Part 1: Rating and performance.
- SR 1893 Rotating electrical machines. Rules and methods for quality control.
-STAS 1893/3-87 - Rotating electrical machines. Marking, packing, supply, documents, guarantees.
-SR CEI 60034-6 - Rotating electrical machines - Part 6: Methods of cooling (IC Code)..
-SR EN 60034-7 - Rotating electrical machines. Part 7: Classification of types of construction, mounting arrangements and
terminal box position (IM Code).
-SR EN 60034-9 - Rotating electrical machines - Part 9: Noise limits.
- SR EN 60034-14 - Rotating electrical machines - Part 14: Mechanical vibration of certain machines with shaft heights 56 mm
and higher - Measurement, evaluation and limits of vibration severity.
- SR CEI 60034-17 - Rotating electrical machines - Part 17: Cage induction motors when fed from converters - Application guide
- SR EN 60529 Degrees of protection provided by enclosures (IP Code).
- SR CEI 60072-1 - Dimensions and output series for rotating electrical machines. Part 1: Frame numbers 56 to 400 and flange
numbers 55 to 1080.
The motors are manufactured using class F insulating materials.
Terminal box could be equipped with 1 or 2 cable glands.
The presser size and the supply cable maximum diameter allowed by the cable entry are given in the table 1.
Table 1

Motor type

ASU

Optionally

Frame size
63, 71, 80, 90
100, 112
132
160, 180
200, 225
250
280
315
355
All frame sizes

Presser size
1 x IPE 16 1 x M25
1 x IPE 16 1 x M25
2 x IPE 29 2 x M32
2 x IPE 29 2 x M40
2 x IPE 36 2 x M50
2 x IPE 42 2 x M50
2 x IPE 42 2 x M63
2 x IPE 48 2 x M63
2 x M63
1 x IPE 16 1 x M20

Supply cable max diameter


10.5
12.5
10.5
12.5
26.4
21
26.4
26.5
32
35
38
35
38
44
44
44
44
10.5
11

To connect the supply cable, the motors are equipped with a terminal plate having 6 terminals. The terminal box is normally
positioned on the top of the motor. The motors have earthing screws on frame body and terminal box. The motors are
provided with rolling-contact bearings. The 280-315 frame size motors are equipped with lubricating system permitting the
rolling bearing lubrication while the motors are operating. The bearings are not dimensioned to stand axial forces outside the
motors. The bearing types are shown in the table 2.

INDUCTION MOTORS CATALOGUE

Table 2

Frame size

Table 3

Drive end
2p=2

Frequency
[Hz]
50
60
70
80
85

Non-drive end

63

2p=4,6,8
6202 2Z

2p=2

2p=4,6,8
6202 2Z

71

6203 2Z

6203 2Z

80

6304 2Z

6304 2Z

90

6305 2Z

6305 2Z

100

6306 2Z

6306 2Z

112

6307 2Z

6307 2Z

132

6308 2Z

6308 2Z

160

6310 2Z

6310 2Z

180

6311 2Z

6311 2Z

200

6313 2Z

6313 2Z

225

6314 2Z

6314 2Z

250

6314

NU 314

6314

6314

280

6316

6316

6316

6316

315 SM

6317

6317

6317

6317

315 ML

6316

6319

6316

6319

355

6319

6322

6319

6322

Noise level
dB(A)
5
6
10
13
15

The producer may use other bearing types as well.


The most commonly used mounting arrangements are
IM 1001,1011, 2001, 3001, 3011 according to SR EN
60034-7 (IEC 34-7; DIN IEC 34-7 part.7).
Excepting the IM 1011 and IM 3011 mounting
arrangements, the motors having two free shaft ends
are also available upon request.
The protection degree of the motors is IP 55, according
to SR EN 60034-5 (IEC 34-5; DIN VDE 0530-part.5 ).
The cooling system of the motors is IC 411 according
SR EN 60034-6. Cooling fluid is environement air.
Motor cooling is done by a fan mounted on the motor
shaft.
The rated duty of the motors is the continuous duty S1,
according to EN 60034-1 (IEC 34-1; DIN VDE 0530part.1).

The nominal parameters shown in the tables refer to a service factor SF=1.
Motors have to be supplied by 3 phase voltage according to norms EN 60034-1. Motors in frame size 63-90 have to be supplied
with max. voltage of 500V and motors in frame sizes 100- 315 have to be supplied with max voltage of 690V. Rated frequency is
50 Hz. The usual voltages are: 220 V, 230 V, 380 V, 400 V, 415 V, 440 V, 460 V, 480 V, 500 V, 660 V and 690 V.The allowed
voltage fluctuation is 5% of rated voltage. At request, the motors could be manufactured for frequency of 60Hz.
The motors can also be fed from PWM frequency converters (VACON or similar) according to the torque/speed characteristic
M=f(Hz) given in Annex 1. The motors can be supplied by frequency convertors - puls width modulation control, vibration levels
are according to EN 60034-14, vibration level may increase for motors in load in certain frequency ranges according to IEC TS
60034-25.
Maximum noise levels of motors are according to SR EN 60034-9.
The noise level of self cooled motors supplied by frequency convertors increase when motors rotation speed increase.
The expected average values of noise increase compained with noise levels indicated in norm EN 60034-9 are mentioned in
table 3:
The magnetic noise of motors supplied by frequency convertors can be kept inside allowed range by means of frequency
convertor controller.
On request, the motors can be equipped with the following optional devices:
- PTC thermistors in stator winding
- PT 100 (thermoresistance) in stator winding or bearings
- heating resistance
The above, as well as well as after optional devices have to be agreed with the manufacturer.
The tehnical parameter tolerances are in keeping with EN 60034-1 and are shown in table 4.

INDUCTION MOTORS CATALOGUE

Table4

No

Parameter name

Tolerances

Efficiency - power lower


than or equal to 50kW
- power higher than 50kW

- 15% din (1-)

Power factor (cos )

1/6 of (1-cos ), min 0,02 and max 0,07

Slip (at full load and


operating temperature)

+ / - 20% of the slip guaranted value

Initial starting current

+ 20% of the guaranteed starting current (without lower limit)

Initial starting torque

Maximum torque

- 10% din (1-)

- 15% .... + 25% of the guaranteed value


(+ 25% only on express demand)
- 10% of the torque guaranteed value, with the specification that after applying this
tolerance, the torque should remain equal or higher than 1,6 or 1,5 times the nominal
torque

Annex 1- Torque/speed characteristic of the motors fed from PWM frequency converters

1,1
1
Forced
ventilation

0,9

Size 200 355


self ventilation

0,8

M/Mn

0,7

Size 63 180
self ventilation

0,6
0,5
0,4
0,3
0,2
0,1
0
0

10

20

30

40

50

60

f[Hz]

INDUCTION MOTORS CATALOGUE

70

80

90

100

IE3 HIGH EFFICIENCY


Motor
type

Rated
power
[kW]

Rated
speed
[rpm]

Current
(400V)
A

100%

75%

50%

Cos

Ip
In

Mp
Mn

Mmax
Mn

J
[kgm2]

LPA
dB(A)

Weight
[kg]

2 poles
E3-ASU
132Sb-2
E3-ASU
160Ma-2
E3-ASU
160Mb-2
E3-ASU
160L-2
E3-ASU
180M-2
E3-ASU
200La-2
E3-ASU
200Lb-2
E3-ASU
225M-2
E3-ASU
250M-2
E3-ASU
280S-2
E3-ASU
280M-2
E3-ASU
315S-2
E3-ASU
315M-2
E3-ASU
315MX-2
E3-ASU
315LY-2
E3-ASU
355M-2
E3-ASU
355La-2
E3-ASU
355Lb-2

7,5

2936

13.2

91.38

91.08

88.78

0.903

7.53

2.6

2.6

0.02837

67

113

11

2931

18.3

91.89

91.49

90.69

0.946

7.48

2,56

3.05

0.04247

77.5

144

15

2931

26,5

91.9

91.5

90.7

0.89

7.89

3.18

3.95

0.05114

77.8

147

18,5

2931

31.5

92.63

92.23

91.43

0,917

6.78

2.02

2,59

0.06665

74.2

184

22

2956

37.4

93.07

92.97

91.37

0.905

8.99

2.43

3.6

0.10974

80.7

255

30

2949

58.0

93.86

93.66

92.36

0.935

8.2

2.13

4.73

0.18016

78.4

305

37

2969

61.5

94.81

94.61

93.31

0.918

9.7

2.22

2.88

0.22539

72.2

360

45

2956

75.0

94.46

94.66

93.86

0.918

7.78

2.19

2.71

0.25668

76.6

407

91.0

95.33

95.53

94.73

0.918

9.15

3.35

4.15

0.61543

78.2

610

55

2976

75

2970

126

95.04

95.04

94.34

0.916

7.05

1.79

2.49

0.63639

77.8

673

90

2964

149

95.5

95.2

94.0

0.915

8.28

2.58

3.87

0.71913

79

704

110

2964

176.7

95.28

95.28

94.48

0.94

7.98

2.28

2,72

1.03957

79.6

815

132

2970

216.6

95.5

95.3

94.6

0,92

8.14

2.43

3.51

1.28301

80.7

934

160

2979

263

95.99

95.59

93.89

0,916

8.18

2.64

2.2

1.93201

80.8

1092

200

2973

325

95.89

95.49

93.79

0,912

7,89

2,65

2,28

2.17095

92.9

1232

250

2980

427

95.9

95.7

94.3

0.88

6.5

2.2

2.8

3.42549

82

1483

280

2980

478

96

95.7

94.3

0.88

6.5

2.2

2.5

3.80611

99

1583

315

2980

537

96.1

95.7

94.1

0.88

6.5

2.3

2.9

4.09157

83

1783

4 poles
E3-ASU
132M-4
E3-ASU
160M-4
E3-ASU
160L-4
E3-ASU
180M-4
E3-ASU
180L-4
E3-ASU
200La-4
E3-ASU
225S-4
E3-ASU
225M-4

7,5

1467

15

91.96

91.56

90.96

0.785

7.7

2.99

4.23

0.05246

54

108

11

1473

19.4

92.83

92.13

89.63

0.88

9.18

2.52

3.3

0.09736

55

160

15

1452

26

92.15

91.35

89.05

0.91

7.5

2.2

2.8

0.10926

67

206

18,5

1471

33

92.7

92.6

91.6

0.87

7.7

2.3

2.8

0.17231

70

221

22

1470

39.5

93.2

93.1

91.4

0.86

7.8

2.3

2.8

0.19262

79

256

30

1485

59.6

93.87

93.47

91.87

0.793

8.7

2.77

3.06

0.31241

70

354

37

1479

65

94.83

94.63

93.43

0.876

7.55

2.28

2.75

0.44356

70

469

45

1463

76.5

94.99

94.89

93.99

0.896

8.1

2.18

2.46

0.49851

72.6

495

INDUCTION MOTORS CATALOGUE

Motor
type

E3-ASU
250M-4
E3-ASU
280S-4
E3-ASU
280M-4
E3-ASU
315S-4
E3-ASU
315M-4
E3-ASU
315MX-4
E3-ASU
315LZ-4
E3-ASU
355M-4
E3-ASU
355La-4
E3-ASU
355Lb-4
E3-ASU
355Lxa-4
E3-ASU
355Lxb-4

Rated
power
[kW]

Rated
speed
[rpm]

Current
(400V)
A

55

1485

75

Cos

Ip
In

Mp
Mn

Mmax
Mn

J
[kgm2]

LPA
dB(A)

Weight
[kg]

94.39

0,88

7.98

2.59

2.94

1.07146

73.3

616

95.15

94.55

0.8

7,9

2.8

3.2

1.10348

74

694

95.2

95.1

94.4

0.87

2.9

2.9

1.22621

76

729

186

95.49

95.29

94.29

0.897

2.5

3.5

1.9063

77.5

849

1478

221

95.62

96.22

95.72

0.9

2.5

2.5

2.04358

78

944

160

1478

277

95.85

95.65

94.65

0.87

7.2

2.3

2.6

3.30966

79

1112

200

1481

341

96.1

96

95

0.88

6.8

2.9

2.9

4.12175

79

1262

250

1485

472

96.1

95.7

94.7

0.88

6.5

2.3

2.3

6.79104

96

1748

280

1485

472

96.2

95.7

94.9

0.89

6.3

2.4

2.4

7.5456

83

1828

315

1485

531

96.2

95.8

95.2

0.89

6.6

2.5

2.5

7.99833

84

2103

355

1491

583.68

96.02

96.22

95.62

0.92

8.15

1.34

3.81

9.2

75.5

2209

400

1488

663

96.1

96.3

95.7

0.9

8.35

1.32

4.1

9.6

76

2386

100%

75%

50%

95

94.87

94.99

1485

141.5

95.35

90

1480

157.5

110

1477

132

6 poles
E3-ASU
160M-6
E3-ASU
160L-6
E3-ASU
180L-6
E3-ASU
200L-6
E3-ASU
200La-6
E3-ASU
225M-6
E3-ASU
250M-6
E3-ASU
280S-6
E3-ASU
280M-6
E3-ASU
315S-6
E3-ASU
315M-6
E3-ASU
315MX-6
E3-ASU
315LY-6
E3-ASU
315LZ-6
E3-ASU
355M-6
E3-ASU
355L-6

7,5

983

15.5

90.6

91.2

90.1

0.778

8.31

2.53

3.8

0.12738

68.2

153

11

980

20.5

91.16

92.36

92.26

0.85

2.03

2.49

0.17461

62.1

181

15

976

27

91,75

91.65

90.15

0.878

7.73

1.95

2.01

0.28296

66.7

223

18,5

981

34

92.04

92.04

91.04

0,849

7,74

1.96

3.46

0.37283

64.4

283

22

980

39.3

92.35

92.15

91.45

0.876

7,46

2.12

2.62

0.45198

70

289

30

980

52

93

93.3

92.4

0.893

7.11

1.96

2.74

0.68931

72

392

37

988

66

94.74

94.64

94.44

0.855

7.29

2.72

2.84

1.4207

67

618

45

985

80

95.07

95.17

94.27

0.862

8.93

2.42

3.54

1.51284

64.5

689

55

986

101

94.61

94.81

94.31

0.833

8.13

3.63

2.65

1.65691

66

729

75

988

131

96.1

96.2

95.6

0.859

8.97

2.53

3.03

2.79602

75

849

90

987

155.5

95.12

95.42

95.12

0.877

8.96

2.5

3.12

3.42153

76

961

110

992

198.6

95.2

95.1

94.1

0.837

6.5

2.5

2.2

5.25397

71.2

1062

132

988

223

95.71

96.01

95.81

0.884

5.4

2.2

2.2

5.91072

72

1162

160

986

285

95.61

95.91

95.71

0.841

5.4

6.56139

71.2

1272

200

987

338

96

95.7

94.9

0.89

2.1

2.1

8.90799

94

1783

250

989

427

96

95.7

95

0.88

2.5

2.5

9.7988

94

1833

INDUCTION MOTORS CATALOGUE

E3-ASU - IM 1001 (IMB3) series induction motors

HA

AC

HD

AA

B
BB

AB

X-X

GA
Frame
size
Baugr
e
Hauteur
daxe

132Sb

216

140

89

132

12

132M

216

178

89

132

12

160M,
Ma,Mb

254

210

108

160

14,5

160L

254

254

108

160

180Ma,
La

279

241/279

121

180Mb,
Lb

279

241/279

200L

318

200La
200Lb

H-

Fh9

GA

AA

AB

BB

BC

HA

AC

HD

80

10

41

60

264

200

69

19

263

400

653

80

10

41

60

264

250

69

19

263

400

653

42
k6

110

12

45

M
16

80

320

300

80

20

317

471

660

14,5

42
k6

110

12

45

M
16

80

320

300

80

20

317

471

710

180

14,5

48
k6

110

14

51,5

M
16

80

360

340

87

25

357

507

730

121

180

14,5

48
k6

110

14

51,5

M
16

80

360

340

87

25

357

507

790

305

133

200

18,5

55
m6

110

16

59

M
20

82

400

380

95

25

396

576

897

318

305

133

200

18,5

55
m6

110

16

59

M
20

82

400

380

95

25

396

576

947

318

305

133

200

18,5

55
m6

110

16

59

M
20

82

400

380

95

25

396

576

1017

0,5

38
k6
38
k6

M
12
M
12

INDUCTION MOTORS CATALOGUE

E3-ASU - IM 1001 (IMB3) series induction motors

Frame
size
Baugre
Hauteur
daxe
225Sb

356

286/311

149

225

225Ma

356

286/311

149

225

225Mb

356

286/311

149

250M

406

349

168

Dm6
A

H-

2p=2

2p=
4,6,8

18.5

18.5

55

225

18.5

250

24

0,5

F h9

2p=2

2p=
4,6,8

60

60

110

55

60

60

65

GA
2p=2

2p=
4,6,8

AA

AB

18

64

M20

100

450

18

59

64

M20

100

450

16

18

59

64

M20

100

450

18

18

64

69

M20

120

500

2p=2

2p=
4,6,8

140

140

16

110

140

140

140

280S

457

368

190

280

24

65

75

140

140

18

20

69

79.5

M20

120

550

280M

457

419

190

280

24

65

75

140

140

18

20

69

79.5

M20

120

550

315S

508

406

216

315

28

65

80

140

170

18

22

69

85

M20

130

630

315M

508

457

216

315

28

65

80

140

170

18

22

69

85

M20

130

630

315MX

508

457

216

315

28

65

80

140

170

18

22

69

85

M20

120

630

315LY

508

508

216

315

28

65

80

140

170

18

22

69

85

M20

120

630

315LZ

508

508

216

315

28

65

80

140

170

18

22

69

85

120

630

355M

610

560

254

355

28

70

100

140

210

20

28

74.5

106

M20

M24

110

714

355La
Frame
size
Baugre
Hauteur
daxe
225Sb

610

630

254

355

28

70

100

140

210

20

28

74.5

106

M20

M24

110

714

430

114

25

446

635

1060

225Ma

430

114

25

446

635

980

1010

225Mb

430

114

25

446

635

1060

250M

503

121

30

500

687

1130

1130

280S

460

147

30

500

758

1170

1170

L
BB

BC

HA

AC

HD
2p=2

2p>2

280M

500

147

30

500

758

1210

1210

315S

528

155.5

30

560

826

1245

1275

315M

568

155.5

30

560

826

1285

1315

315MX

588

176

26

620

880

1330

1360

315LY

588

176

26

620

880

1400

1430

315LZ

588

176

26

620

880

1430

355M

695

177

32

705

960

1380

1490

355La

695

177

32

705

960

1460

1570

INDUCTION MOTORS CATALOGUE

M20

X
M

AC

HD

E3-ASU - IM 3001 (IMB5) series induction motors

T
E
L

X-X

GA

Frame size
Baugre
Hauteur
daxe

Nj6

Fh9

GA

AC

HD1

LA

LB

L1

132Sb

265

230

300

14,5

38
k6

80

10

41

M12

263

268

12

573

653

695

132M

265

230

300

14,5

38
k6

80

10

41

M12

263

268

12

573

653

695

160M,Ma,Mb

300

250

350

18,5

42
k6

110

12

45

M16

317

311

14

550

660

775

160L

300

250

350

18,5

42
k6

110

12

45

M16

317

311

14

600

710

825

180Ma,La

300

250

350

18,5

48
k6

110

14

51,5

M16

357

327

12

620

730

785

180Mb,Lb

300

250

350

18,5

48
k6

110

14

51,5

M16

357

327

12

680

760

815

200L

350

300

400

18,5

55
m6

110

16

59

M20

396

380

16

787

897

945

200La

350

300

400

18,5

55
m6

110

16

59

M20

396

380

16

837

945

995

200Lb

350

300

400

18,5

55
m6

110

16

59

M20

396

380

16

907

1015

1065

INDUCTION MOTORS CATALOGUE

E3-ASU - IM 3001 (IMB5) series induction motors

Frame size
Baugre
Hauteur
daxe
225Sb
225Ma
225 Mb
250M
280S
280M
315S
315M
315MX
315LY
315LZ
355M
355L
355Lxa
355Lxb
Frame size
Baugre
Hauteur
daxe
225Sb
225Ma
225 Mb
250M
280S
280M
315S
315M
315MX
315LY
315LZ
355M
355L
355Lxa
355Lxb

Dm6
M
400
400
400
500
500
500
600
600
600
600
600
740
740
740
740

N
j6
350
350
350
450
450
450
550
550
550
550
550
680
680
680
680
LB

450
450
450
550
550
550
660
660
660
660
660
800
800
800
800

18.5
18.5
18.5
18.5
18.5
18.5
24
24
24
24
24
24
24
24
24
L

5
5
5
5
5
5
6
6
6
6
6
6
6
6
6

Fh9

GA

2p=2

2p>2

2p=2

2p>2

2p=2

2p>2

2p=2

2p>2

2p=2

55
55
60
65
65
65
65
65
65
65
70
70
-

60
60
60
65
75
75
80
80
80
80
80
100
100
100
100

110
110
140
140
140
140
140
140
140
140
140
140
-

140
140
140
140
140
140
170
170
170
170
170
210
210
210
210

16
16
18
18
18
18
18
18
18
18
20
20
-

18
18
18
18
20
20
22
22
22
22
22
28
28
28
28

59
59
64
69
69
69
69
69
69
69
74.5
74.5
-

64
64
64
69
79.5
79.5
85
85
85
85
85
106
106
106
106

M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20 M24
M20 M24
M24
M24

L1

2p=2

2p>2

2p=2

2p>2

2p=2

2p>2

920
870
950
985
985
1023
1102
1142
1155
1225
1230
1310
-

920
870
920
985
985
1023
1102
1142
1185
1255
1255
1270
1350
1620
1620

1060
980
1060
1130
1170
1210
1245
1285
1330
1400
1380
1460
-

1060
1010
1060
1130
1170
1210
1275
1315
1360
1430
1430
1490
1570
1760
1830

1105
1025
1105
1175
1270
1310
1345
1355
1430
1500
1480
-

1105
1055
1105
1175
1270
1310
1385
1415
1460
1530
1530
1590
1670
1860
1930

INDUCTION MOTORS CATALOGUE

2p>2

AC

HD1

LA

446
446
446
500
500
500
560
560
620
620
620
705
705
720
720

410
410
410
475
437
478
478
510
510
565
565
565
605
605
605

18
18
18
20
20
20
20
20
25
25
25
35
35
35
35

24dc
24dc
24dc
24dc
24dc

24dc

AIM SERIES OF THREE PHASE WOUND ROTOR INDUCTION MOTORS FOR HOISTING UNITS DRIVE
AIFM SERIES OF THREE-PHASE WOUND ROTOR ELECTROMAGNETIC BRAKE INDUCTION MOTORS
FOR HOISTING UNITS DRIVE
The AIM series of three-phase induction motors with wound rotor and brushes in permanent contact with the rings and AIFM
series, derived from the first one, equipped with an electromagnetic brake are meant for hoisting units drive.
The motors comply with the requirements of the following standards and norms:
- SR EN 60034-1 Rotating electrical machines. Part 1: Rating and performance.
- SR 1893 - Rotating electrical machines. Rules and methods for quality control.
- STAS 1893/3-87 - Rotating electrical machines. Marking, packing, supply, documents, guarantees.
- EN 60034-6 - Rotating electrical machines - Part 6: Methods of cooling (IC Code).
- EN 60034-7 - Rotating electrical machines. Part 7: Classification of types of construction, mounting arrangements and
terminal box position (IM Code).
- EN 60034-9 - Rotating electrical machines - Part 9: Noise limits.
- EN 60034-14 - Rotating electrical machines - Part 14: Mechanical vibration of certain machines with shaft heights 56 mm
and higher - Measurement, evaluation and limits of vibration severity.
- EN 60529 - Degrees of protection provided by enclosures (IP code).
- CEI 60072-1 - Dimensions and ouput series for rotating electrical machines. Part 1: Frame numbers 56 to 400 and flange
numbers 55 to 1080.
- SR 6968/1-2012 - Wound-rotor induction motors for hoisting and transport installations. Special technical requirements.
- SR 6968/2-2012 - Ring asynchronous motors for hoisting an transport installation. Correlation of output powers with
mounting dimensions.
The motors are intended to operate under the following environmental conditions:
0
0
-Temperature
- 33 C....... + 40 C
-Relative humidity: max. 80% la 200 C
-Maximum altitude of installation: 1000 m (3000 feet) above sea level.
The motors are solid grey -cast iron mechanical construction; the housing is fitted with cooling fins and is blown by an outer
fan placed at the non-drive end side, protected by a fan cover.
The motors are provided with rolling-contact bearings.
The bearings types, appropriate to each frame size motors are given in table 1.
Table 1
Bearing symbol
Frame size

AIM

AIFM
Non drive-end
6306 P6 EL

Brush dimensions

100

Drive-end
6306 P6 EL

Non drive-end
6306 P6 EL

Drive-end
6306 P6 EL

112

6307 2Z P63 EL

6307 2Z P63 EL

6307 2Z P63 EL

6307 2Z P63 EL

16 x 8

132

6308 2Z P63 EL

6308 2Z P63 EL

6308 2Z P63 EL

6308 2Z P63 EL

20 x 10

160

6310 2Z P63 EL

6310 2Z P63 EL

6310 2Z P63 EL

6310 2Z P63 EL

25 x 12.5

180

6311 2Z P63 EL

6311 2Z P63 EL

6311 2Z P63 EL

6311 2Z P63 EL

25 x 12.5

200

6312 P6

6312 P6

32 x 16

225

6313 P6

6313 P6

32 x 16

250

NU 315 P6

6315 P6

40 x 20

280

NU 317 P6

6317 P6

40 x 20

16 x 8

The bearings are not dimensioned to stand axial forces outside the motors. The stator and rotor common terminal box,
located on top the motor, is provided with cable entries on both sides and normalized glands. The terminal box allows for the
inspection of the slip rings and brushes. The brush dimensions are given in table 1.
A six terminal plate allowing the stator winding star or delta connection is fitted inside the terminal box. AIFM motors fave an
added terminal plate for brake supply. The rotor cables are connected to the terminals on the brush holder.
The housings are provided with earthing terminals.
The protection degree of the AIFM type motors is:
- IP 55 for frame sizes 112-180
The protection degree of the AIM type motors is:
- IP 55 for frame sizes 112-180,250,280
- IP 54 for the other frame sizes
The usual mounting arrangements, according to SR EN 60034-7 (IEC 34-7) are; IM 1001, IM 2001, IM 3001, IM 1011 and IM
3011. The AIM series are also available in IM 1002 mounting arrangement.
The stator and rotor windings are executed in class F of insulation. The motors are designed for being supplies from a three phase mains with line voltage of 220V, 230V, 380V, 400 V at 50 Hz frequency. They may be, as well manufactured as to meet
other intermediate voltages and the 60 Hz frequency.
INDUCTION MOTORS CATALOGUE

The supply source could be motor phase or a separate source. The brakes type AC have to be supplied at 230V (respectivly
220V) 50 Hz in delta connection 400V (380 V) 50Hz in star connection (see fig.2). Brake supply voltage of AIFM motors is
mentioned in table 4.
A starting rheostat, inserted in the rotor circuit, setting up the starting time at 6-7 sec., enables the starting of the motors.
The motors manufacturer does not supply the starting rheostat.
The AIM and AIFM motors are designed to operate under an intermittent periodic duty S3, characterized by six starts per hour
and an operating factor of 40%.
Table 4 includes the technical parameters corresponding to other rated duties ( S1, S2, S4 ).
The rated output refers to rated duty and the standard environmental conditions.
For environmental conditions different from the temperate climate standard values, the output varies as shown in tables 2a
and 2b.
Table 2a
Table 2b
Ambient temperature
Height [m]
0-1000
1001-2000 2001-3000 3001-4000
40 50
60
0
[ C]
Effective power
Effective power
100
94
86
77
100 90
80
[%P]
[%P]
According to SR EN 60034-1:2005 (IEC 34-1) the technical parameters are subject to the following tolerances table3.
Table 3
Parameter name
Efficiency
- power lower than or equal to 50kW
- power higher than 50kW

Tolerances
- 15% din (1 - )
- 10% din (1 - )

Power factor (cos )


Slip (at full load and operating temperature)
Maximum torque
Moment of inertia

1
6 of (1 cos ), min 0,02 and max 0,07
+/- 20% of the slip guaranteed value
- 10% of the torque guaranteed value, with the specification
that after applying this tolerance, the torque should remain
equal or higher than 1,6 or 1,5 times the nominal torque
+ / - 10% of the guaranteed value

The vibration levels, in mm/ s comply with SR EN 60034-14:2004/A1:2008. The maximum permissible values of the
motors noise levels, expressed by the sound power are in accordance to SR EN 60034-9:2006 (IEC 34-9).
Table 4
Brake
Frame size

Supply
Supply options

Brake type

Braking torque
(Nm)

Voltage
(V)

Motor voltage

External source

100

FEA 5

50

24dc

motor terminals via rectifier

Yes

112

FEA 5

50

24dc

motor terminals via rectifier

Yes

132

FEA 10

100

24dc

motor terminals via rectifier

Yes

160

FEA 20

200

24dc

motor terminals via rectifier

Yes

180

FEA 30

300

24dc

motor terminals via rectifier

Yes

Figure 2 - Supply diagram of FEA BRAKE

INDUCTION MOTORS CATALOGUE

271

598
638

Das könnte Ihnen auch gefallen