Sie sind auf Seite 1von 1

Wood Member Under Combined Axial + Moment

Name:

Keaten Claney

Job #:

#20155

Date:

8/8/2016

Client:

Sonic

Member Parameters
Member Depth
Member Width
Spacing
Joist Span Length
Joist Design Load (ASD)
Cantilevered Length
Simple Span Length
Unbraced Length
Depth To Breadth
Modulus of Elasticity
Minimum Modulus of Elasticity
Factored Min Modulus
Design Bending Stress
Effective Area
Wind Pressure (parapet)
Wind Pressure (wall)

d
b
s
L(joist)
w
Lc
L
Lu
d/b
E
Emin
Emin'
Fb
A
p(parapet)
p(wall)

5.5 in
1.5 in
16 in
30 ft
38 psf
6 ft
13 ft
8 ft
3.67
1600000 in^4
580000 in^4
551000 in^4
900 psi
56.33 ft^2
22.6 psf
12.6 psf

Distance between Blocking


NDS 2012 Supp. Table 4F
NDS 2012 Supp. Table 4F
NDS 2012 Supp. Table 4F
ASD
ASD

Stability Bracing Requirement

The ends shall be held in position, as by full blocking, bridging, hangers, nailing, or
bolting to other framing members or other acceptable means.

Bracing Requirement Met?

Yes

Adjustment Factors

Load Duration Factor


Wet Service Factor
Temperature Factor
Beam Stability Factor

Cd

1.6
1
1
1.00

Cm
_=(1+(_
/ _ ^ ))/1.9([(1+(_/ _ ^ ))/1.9]^2((_ / _ ^ ))/.95)
Ct
Cl

Effective Length
Slenderness Ratio

Le
Rb

Reference Bending Design Value


Effective Bending Stress

Fb*
FbE

Size Factor
Flat Use Factor
Incising Factor
Repetitive Member Forces

Cf
Cfu
Ci
Cr

14.42
20.56

=((_ )/^2 )

Table 3.3.3
Eq. 3.3-5

1440 psi
1563.71 psi

_=1.2/ _ ^2

1
1
1
1

Moment Capacity
Actual Moment
Actual Bending Stress
Allowable Bending Stress
Axial Load

M
fb
fb'
P

542.4 lb-ft
860.67 psi
1440 psi
760.00 lb

_=6/(^2 )

OK

Axial Capacity
Compressive Strength
Fc
c
c
FcE
FcE
Fc*
Fc*
Column Continually Supported All Directions?
Column Stability Factor
Cp
Effective Length
le
Slenderness
le/d
Design Comrpessive Strength
Fc'
Required Compressive Stress
fc
Combined Loading Check

1350 psi
0.8
563 psi
1350 psi
No
0.373
156 in
28.36
503.19 psi
92.12 psi

OK

0.75

OK