Infra DG Issue Battery Bank Issue SMPS Issue AC Issue Shelter Issue PIU Issue

ATC
24
13
15
10
7
14

Owner Issue
8

Q4 PM
2013
Done
Date

Q1 PM
2014
Done
Date

Err:512

30-Apr-14

PM
Done
by
Engg

EIL ID

Site ID UWL

BTS Make
(Ericsson
/ Huawei/
others)

FOR004

UW_BIHAR_3367

Ericsson

TANDW1

UW_BIHAR_3606

Ericsson

SINGH
SINGH
ATC INDRAJEET KUMAR SHASHANK

HARHR1

UW_BIHAR_3342

Ericsson

SINGH
SINGH
ATC INDRAJEET KUMAR SHASHANK

HASPU1

UW_BIHAR_3332

Ericsson

Infra
Partner

Ztm
Name

Anshu Gautam
Singh & Noor Alam
ATCKarunendra Narayan

SINGH
SINGH
ATC INDRAJEET KUMAR SHASHANK

NAW010

UW_BIHAR_3250

Ericsson

12-Dec-13

MHDEV1

UW_BIHAR_3671

Ericsson

8-Nov-13

27-Jan-14

Rahul Negi
ATC krishna nandan kumar

SHAM01

UW_BIHAR_2259

Ericsson

18-Oct-13

10-Mar-14

ATC

RAN093

UW_BIHAR_2278

Ericsson

21-Oct-13
20-Jan-14
7-Jan-14

SHB002

UW_BIHAR_2977

Ericsson

26-Nov-13

MNGAL1

UW_BIHAR_3668

Huawei

27-Nov-13

PURNI1

UW_BIHAR_2725

Ericsson

HSNPR1

UW_BIHAR_1889

Huawei

30-Nov-13

SNDES1

UW_BIHAR_1822

Ericsson

20-Dec-13

CHNDI1

UW_BIHAR_3567

Ericsson

18-Dec-13

GODDA2

UW_BIHAR_2838

Ericsson

12-Nov-13

BET014

UW_BIHAR_4226

Huawei

NEW SITE

28-Mar-14

ATC

ATC

26-Feb-14

11-Mar-14

NEW SITE

JANIP1

UW_BIHAR_3564

Ericsson

JAM132

UW_BIHAR_2341

Ericsson

4-Dec-13

BRARI1

UW_BIHAR_2333

Ericsson

10-Dec-13

BAGHV1

UW_BIHAR_3527

Ericsson

25-Dec-13
5-Mar-14
3-Mar-14

1-Mar-14

Santosh Kr Gupta Rahul Negi


Raj

Vipul Kumar

Rahul Negi
ATC krishna nandan kumar
ATC

Rahul Kumar Love


Nirbhay Kumar

ATC

Santosh Kr Gupta Rahul Negi

ATC

Rupesh Kumar Nirbhay Kumar

ATC

Ranveer singh Ramesh Kumar

ATC

Manoj Mrinal Ramesh Kumar

ATC

10-Dec-13

Afroz Alam Shashank Singh

ATC

Rajesh Kumar Pandey


RAHUL DIXIT
Rahul Kumar Love
Nirbhay Kumar

ATC

Sumit KumarSunil Kumar Singh

ATC

Sumit Kumar
Abhishek Kumar Thakur

ATC

Md. Asraf JawedAnshu Gautam

ATC

Rakesh Gupta Ramesh Kumar

ATC

Ritendu Maity

ATC

Pawan KumarSunil Kumar Singh

ATC

Ankur SinghSunil Kumar Singh

DLT019

UW_BIHAR_2830

Ericsson

14-Dec-13

Vipul Kumar

MOKAM4

UW_BIHAR_2822

Ericsson

19/12/13

HLD001

UW_BIHAR_1826

Ericsson

8-Dec-13

BHA046

UW_BIHAR_3350

Ericsson

9-Nov-13

6-Mar-14

ATC

14-Mar-14

ATC

Amit Ranjan Manish Kumar

Imran Sharique Rahul Negi

MNJHA1

UW_BIHAR_1784

Ericsson

28-Dec-13

BRN007

UW_BIHAR_3256

Ericsson

11-Dec-13

12-Mar-14

ATC

Amit Ranjan Manish Kumar

BEG012

UW_BIHAR_3648

Ericsson

27-Nov-13

21-Mar-14

ATC

Mithlesh kr Choubey
Manish Kumar

CHKRI1

UW_BIHAR_3372

Ericsson

6-Dec-13

ATC

Prashant kumar
Shashank Singh

RAN105

UW_BIHAR_4419

Ericsson

NIRMA2

UW_BIHAR_3602

Ericsson

Err:512

KAB001

UW_BIHAR_1823

Ericsson

22-Dec-13

15-Feb-14

Shashank singh
ATC ARVIND KUMAR SINGH

BARKI1

UW_BIHAR_2207

Ericsson

21-Nov-13

11-Mar-14

ATC

Arvind PrasadKaushal
Rai
Kumar Singh

ATC

Arvind PrasadKaushal
Rai
Kumar Singh

ATC
ATC

Virendra Dutt

Vipul Kumar

Vishwanath KumarVishal Anand

BHULI3

UW_BIHAR_4427

Ericsson

Err:512

MALHI1

UW_BIHAR_1824

Ericsson

27-Nov-13

ATC

krishna Kumar Ramesh Kumar

REWAS1

UW_BIHAR_2083

Huawei

24-11-2013

ATC

Somendra Kumar Jha


Avinash Kumar

HUSNG1

UW_BIHAR_3704

Huawei

11-Dec-13

ATC

Ericsson

24-Oct-13

ATC

RAN096

UW_BIHAR_2285

Brajesh KumarSantosh Kr Singh


Ravi singh

Vipul Kumar

SUP004
KOTWA2

UW_BIHAR_2884
UW_BIHAR_3299

Ericsson

28-Nov-13

ATC

ASHOK KUMAR Manish Kumar

Ericsson

27-Nov-13

1-Mar-14

ATC

Mukesh Kr DuttaNirbhay Kumar

ATC

RAN103

UW_BIHAR_4421

Ericsson

Err:512

MHICH1

UW_BIHAR_3703

Huawei

11-Dec-13

ATC

Raghuwansh Kumar
Santosh Kr Singh

JADUP1

UW_BIHAR_3705

Huawei

11-Dec-13

ATC

Raghuwansh Kumar
Santosh Kr Singh

ATC

Raghuwansh Kumar
Santosh Kr Singh

ATC

Akhilesh Kumar
Santosh Kr Singh

PACHD1

UW_BIHAR_3706

Huawei

11-Dec-13

PERSA1

UW_BIHAR_2273

Huawei

25-Dec-13

KAPSH1

UW_BIHAR_3667

Ericsson

24/12/13

26-Feb-14

ATC

Ravi singh

Vipul Kumar

Rahul Raj Sunil Kumar Singh

Date of
PM

Indoor
BTS Type
/Outdoor

Indoor to
Outdoor
[Cabinet]

Outdoor
Cabinet
Fan

NO

OK

Outdoor Outdoor
DC
Cabinet
Cabinet voltage in
LED
Lock - Key Cabinet

30-Apr-14

Outdoor

6201

18-Apr-14

Outdoor

6101

< -48

15-Apr-14

Outdoor

6601

< -48

1-Apr-14

Outdoor

6601

13-Apr-14

Indoor

6601

NO

2-Apr-14

Outdoor

6201

NO

OK

4-Apr-14

OUTDOOR

2954V2

YES

OK

7-Apr-14

OK

NOT OK

> -48

< -48
> -48
OK

OK

< -48

OK

> -48

Outdoor

6101 i

NO

OK

OK

OK

< -48

8-Apr-14

2964 V2

NO

OK

OK

OK

< -48

Normal

9-Apr-14

Outdoor

Huawei

NO

OK

OK

OK

> -48

9-Apr-14

INDOOR

2964V2

YES

OK

OK

> -48

9-Apr-14

Outdoor

Huawei

YES

OK

OK

OK

< -48

14-Apr-14

Outdoor

6101

NO

OK

OK

OK

< -48

15-Apr-14

Outdoor

2954 V2

NO

OK

OK

OK

< -48

4-Apr-14

Indoor

2964V1

NO

OK

OK

22-Apr-14

Outdoor

Huawei

NO

OK

OK

OK

> -48

13-Apr-14

Outdoor

6101

N/A

N/A

N/A

N/A

< -48

24-Apr-14

Outdoor

2954 V1 AC

NO

OK

OK

OK

< -48

10-May-14

Indoor

2964

NO

9-May-14

< -48

Outdoor

6101

NO

13-May-14

Indoor

2964 V2

NO

4-May-14

Outdoor

2954 V2

YES

OK

OK

OK

< -48

7-May-14

Indoor

6201

NO

N/A

N/A

N/A

> -48

22-Apr-14

< -48

Outdoor

6601

NO

OK

OK

OK

< -48

29-Apr-14

Outdoor

6101

NO

OK

OK

OK

< -48

10-Apr-14

Outdoor

6101

NO

OK

NA

OK

48 VDC

12-Apr-14

Outdoor

6101

NO

OK

OK

OK

48 VDC

17-May-14

Outdoor

6101

22-May-14

Outdoor

6202

NO

OK

OK

OK

< -48

14-Apr-14

Outdoor

2954

yes

ok

ok

ok

> -48

11-May-14

Indoor

6201

NO

NOT OK

NOT OK

NOT OK

< -48

11-May-14

Indoor

2964 V1 AC

NO

NO

NOT OK

NOT OK

< -48

1-May-14

Outdoor

2964 V2 DC

NO

OK

OK

OK

> -48

23-May-14

Indoor

6201

NO

28-Apr-14

Indoor

Huawei

NO

OK

OK

OK

< -48

4-Jun-14

Outdoor

Huawei

NO

OK

OK

OK

> -48

Outdoor

6101

NO

OK

OK

NOT OK

> -48

4-Jun-14

4-Jun-14

Indoor

2964 V2 DC

NO

4-Jun-14

Outdoor

Huawei

NO

OK

OK

OK

> -48

5-Jun-14

Outdoor

2954 V2 DC

NO

OK

OK

OK

< -48

5-Jun-14

Outdoor

Huawei

YES

OK

OK

OK

< -48

3-May-14

Outdoor

Huawei

YES

OK

OK

OK

< -48

5-Jun-14

Outdoor

Huawei

YES

OK

OK

OK

< -48

5-Jun-14

Indoor

Huawei

NO

18-May-14

Outdoor

6101

NO

OK

OK

OK

> -48

Site
AC Mains
Site Type dependen RBS Fault IDB Fault
FailNormal/H cy (If site - Internal - Internal
External
ub/Critical will be
Alarm
Alarm
Alarm
down)

DG on
loadExternal
Alarm

High
Room
TempExternal
Alarm

Low
Battery
VoltageExternal
Alarm

Normal

1 Site

No Alarm

No Alarm
Defined & NOT Defined
Working& NOT Defined
Working& NOT Defined
Working& NOT Working

Normal

1 Site

No Alarm

No Alarm Defined & Working


Defined & Working
Defined & Working
Defined & Working

No Alarm

No Alarm Defined & Working


Defined & Working
Defined & Working
Defined & Working

Normal
Normal

No Alarm

No Alarm Defined & Working


Defined & Working
Defined & Working
Defined & Working

Normal

1 Site

No Alarm

No Alarm
Defined & NOT Defined
Working& NOT Defined
Working& NOT Defined
Working& NOT Working

Normal

1 Site

No Alarm

No Alarm Defined & Working


Defined & Working
Defined & Working
Defined & Working

NORMAL

1 Site

No Alarm

No Alarm Defined & Working


Defined & Working
Defined & Working
Defined & Working

Normal

1 Site

No Alarm

No Alarm
Defined & NOT Defined
Working& NOT Working
Other reason
Defined & NOT Working

1 Site

No Alarm

Normal

1 Site

No Alarm

No Alarm Defined & Working


Defined & Working
Defined & NOT Working
Defined & Working

NORMAL

1 Site

No Alarm

No Alarm Defined & Working


Defined & Working
Defined & Working
Defined & Working

Normal

1 Site

No Alarm

No Alarm MUX Not available


MUX Not available
MUX Not available
MUX Not available

Normal

1 Site

No Alarm

No Alarm
Defined & NOT Defined
Working& NOT Defined
Working& NOT Defined
Working& NOT Working

Normal

1 Site

No Alarm

No Alarm
Defined & NOT Defined
Working& NOT Defined
Working& NOT Defined
Working& NOT Working

Normal

3 Sites

No Alarm

No Alarm
Defined & NOT Defined
Working& NOT Defined
Working& NOT Defined
Working& NOT Working

Normal

1 Site

No Alarm

No Alarm Defined & Working


Defined & NOT Defined
Working& NOT Working
Defined & Working

Normal

1 Site

No Alarm

No Alarm

Normal

N/A

No Alarm

No Alarm Alarm MUX Faulty


Alarm MUX Faulty
Alarm MUX Faulty
Alarm MUX Faulty

Normal

1 Site

No Alarm

No Alarm
Defined & NOT Defined
Working& NOT Defined
Working& NOT Defined
Working& NOT Working

Normal

1 Site

No Alarm

No Alarm
Defined & NOT Defined
Working& NOT Defined
Working& NOT Defined
Working& NOT Working

Normal

1 Site

No Alarm

No Alarm
Defined & NOT Defined
Working& NOT Defined
Working& NOT Defined
Working& NOT Working

Normal

1 Site

OK

NORMAL

No Alarm

No Alarm
Defined & NOT Defined
Working& NOT Defined
Working& NOT Defined
Working& NOT Working

Normal

1 Site

No Alarm

No Alarm
Defined & NOT Defined
Working& NOT Defined
Working& NOT Defined
Working& NOT Working

Hub

3 Sites

No Alarm

No Alarm
Defined & NOT Defined
Working& NOT Defined
Working& NOT Defined
Working& NOT Working

NORMAL

NO

NO Defined & NOT Defined


WORKING
& NOT WORKING NA Defined & NOT WORKING

NORMAL

NO

NO Defined & NOT Defined


WORKING
& NOT WORKING NA Defined & NOT WORKING

Normal

1 Site

No Alarm

No Alarm
Defined & NOT Defined
Working& NOT Defined
Working& NOT Defined
Working& NOT Working

Normal

1 Site

No Alarm

No Alarm Defined & Working


Defined & WorkingOther reasonDefined & Working

Normal

1 site

No Alarm

No Alarm
Defined & NOT Working
Defined & Working
Defined & NOT Defined
Working& NOT Working

Normal

1 Site

No Alarm

No Alarm Defined & Working


Defined & Working
Defined & Working
Defined & Working

Normal

1 Site

No Alarm

No Alarm
Defined & NOT Defined
Working& NOT Defined
Working& NOTDefined
Working& NOT Working

Normal

1 Site

No Alarm

No Alarm MUX Not available


MUX Not available
MUX Not available
MUX Not available

Normal

1 Site

No Alarm

No Alarm
Defined & NOT Defined
Working& NOT Defined
Working& NOT Defined
Working& NOT Working

Normal

1 Site

No Alarm

No Alarm

Other reason Other reason Other reason Other reason

No Alarm

No Alarm

Other reason Other reason Other reason Other reason

No Alarm

No Alarm Defined & Working


Defined & WorkingOther reasonDefined & Working

Normal

No Alarm
Defined & NOT Defined
Working& NOT Defined
Working& NOT Defined
Working& NOT Defined
Working& NOT Working

Other reason Other reason Other reason Other reason

OK Defined & NOT Defined


Working& NOT Defined
Working& NOT Defined
Working& NOT Working

Critical

6 Sites

No Alarm

No Alarm
Defined & NOT Defined
Working& NOT Defined
Working& NOT Working
Defined & Working

Normal

1 Site

No Alarm

No Alarm

No Alarm

No Alarm Defined & Working


Defined & Working
Defined & Working
Defined & Working

Normal

Other reason Other reason Other reason Other reason

Normal

2 Sites

No Alarm

No Alarm
Defined & NOT Defined
Working& NOT Defined
Working& NOT Defined
Working& NOT Working

Normal

2 Sites

No Alarm

No Alarm
Defined & NOT Defined
Working& NOT Defined
Working& NOT Defined
Working& NOT Working

Normal

2 Sites

No Alarm

No Alarm
Defined & NOT Defined
Working& NOT Defined
Working& NOT Defined
Working& NOT Working

Normal

1 Site

No Alarm

No Alarm

Other reason Other reason Other reason Other reason

Normal

1 Site

No Alarm

No Alarm

Other reasonDefined & WorkingOther reason Other reason

Rectifier
FailExternal
Alarm

Shelter
door
openExternal
Alarm

Fire &
SmokeExternal
Alarm

DG fail to
startExternal
Alarm

Specific
Issue if
Alarm is
not
working

VSWR
Measure
ment

Defined & NOT Defined


Working& NOT Defined
Working& NOT Defined
Working& NOT Defined
Working& NOT Working YES

Weather
Proofing

Check all
the
Feeder
cables,
Radio
cables
for any
physical
damage

OK

OK

Defined & Working


Defined but NotDefined
Working
but NotDefined
Working
but NotDefined
Working& NOT a=1.20,b=1.23,c=1.25
Working
Wether Proofing Done

OK

Defined & Working


Defined but NotDefined
Working
but NotDefined
Working
but NotDefined
Working& NOT a=1.20,b=1.23,c=1.21
Working
Wether Proofing Done

OK

Defined & Working


Defined but NotDefined
Working
but NotDefined
Working
but NotDefined
Working& NOT a=1.27,b=1.23,c=1.27
Working
Wether Proofing Done

OK

Defined & NOT Defined


Working& NOT Defined
Working& NOT Defined
Working& NOT Working
A1-1.23,A2-1.20,B1-1.18,B2-1.19,C1-1.22,C2-1.17
Other reason
OK

OK

Other reason Other reason Other reason Other reason


CELL A=1.23,1.21,CELL
Other reason
B=1.24,1.27,CELLOK
C=1.26,1.28 OK
Defined & Working
Defined & Working
Defined & Working
Defined & Working
Defined
A=1.21,1.23,B=1.23,1.23,C=1.23,1.22
& Working
Wether Proofing Done
Defined & NOT Working
Other reason Other reason Other reason Other reason

ok

OK

OK
OK

Defined & NOT Working


Other reason Other reason Other reason
CELL A=1.23,1.21,CELL
Other reason
B=1.24,1.27,CELLOK
C=1.26,1.28
Defined & Working
MUX Not available
MUX Not available
Defined & WorkingOther reason
1.22,1.24/1.15,1.13/1.15,1.12
OK

OK

Defined & Working


Defined & Working
Defined & Working
Defined & Working
Defined
A=1.23,1.23,B=1.23,1.23,C=1.23,1.21
& Working
Wether Proofing Done

OK

MUX Not available


MUX Not available
MUX Not available
MUX Not available
MUX Not 1.22,1.19/1.24,1.22/1.20,1.21
available
OK

OK

Defined & NOT Defined


Working& NOT Defined
Working& NOT Defined
Working& NOT Defined
Working
A(1.28,1.22),
& NOT Working
B(1.15,1.20), C(1.25,1.18)
OK

OK

Defined & NOT Defined


Working& NOT Defined
Working& NOT Defined
Working& NOT Defined
Working
A(1.13,1.18),
& NOT Working
B(1.23,1.19), C(1.23,1.22)
OK

OK

Defined & NOT Defined


Working& NOT Defined
Working& NOT Defined
Working& NOT Defined
Working
Cell A=1.18,1.19
& NOT Working
Cell B=1.29,1.19 Cell C=1.29,1.19
OK

OK

Defined & Working


MUX Not available
MUX Not available
Defined & Working
Defined &1.28,1.27/1.15,1.13/1.15,1.13
Working
OK
Other reason Other reason Other reason Other reason Other reason

OK

OK
OK

Alarm MUX Faulty


Alarm MUX Faulty
Alarm MUX Faulty
Alarm MUX
A1-Faulty
1.23
Alarm
dbm,
MUX
A2- Faulty
1.27 B1- 1.12, B2- 1.19, C1OK 1.18, C2- 1.18
OK
Defined & NOT Defined
Working& NOT Defined
Working& NOT Defined
Working& NOT Defined
Working& NOT Working ok

Wether Proofing Done

OK

Defined & NOT Defined


Working& NOT Defined
Working& NOT Defined
Working& NOT Working
Alarm
A=1.25,1.21,B=1.19,1.25,C=1.22,1.19
MUX Faulty
OK

OK

Defined & NOT Defined


Working& NOT Defined
Working& NOT Defined
Working& NOT Defined
Working& NOT Working
NOT MEASURED

OK

OK

Defined & NOT Defined


Working& NOT Defined
Working& NOT Defined
Working& NOT Working
Alarm MUX Faulty

OK

OK

OK

OK

N/A

Other reason Other reason Other reason Other reason Other reason
Defined & NOT Defined
Working& NOT Defined
Working& NOT Defined
Working& NOT Defined
Working& NOT Working ok
Defined & NOT Defined
Working& NOT Defined
Working& NOT Defined
Working& NOT Working
Other reason

Wether Proofing Done

OK

ok

OK

OK

NA

NA

NA

NA Defined & NOT Working OK

OK

OK

NA

OK

NA

NA Defined & NOT Working OK

OK

OK

Defined & NOT Defined


Working& NOT Defined
Working& NOT Defined
Working& NOT Defined
Working& NOT Working

OK

OK

Defined & WorkingOther reason Other reason Other reason Other reason

ok

OK

OK

Defined & NOT Defined


Working& NOT Defined
Working& NOT Defined
Working& NOT Working
Defined & Working

1.3

ok

ok

Defined & Working


Defined & Working
Defined & Working
Defined & Working
Defined & Working
A=1.12,B=1.11,C=1.15
Wether Proofing Done

OK

Defined & NOT Defined


Working& NOT Defined
Working& NOT Defined
Working& NOT Working
Alarm MUX Faulty

OK

OK

OK

MUX Not available


MUX Not available
MUX Not available
MUX Not available
MUX Not available

ok

OK

OK

Defined & NOT Defined


Working& NOT Defined
Working& NOT Defined
Working& NOT Working
Alarm
A=1.22,1.27,B=1.24,1.21,C=1.19,1.21
MUX Faulty
OK
Other reason Other reason Other reason Other reason Other reason

ok

OK

OK
OK

Other reason Other reason Other reason Other A1reason


1.11 dbm,
OtherA2reason
1.16, B1- 1.22, B2- 1.21, C1OK 1.20, C2- 1.30
OK
Other reason Other reason Other reason Other reason Other reason

done

OK

OK

Defined & Working


Defined & NOT Defined
Working& NOT Defined
Working& NOTA1=1.24,A2=1.25,B1=1.25,B2=1.26,C1=1.25,C2=1.25
Working
Other reason
OK
OK
Other reason Other reason Other reason Other reason Other reason
NOT MEASUREMENT

OK

OK

Other reason Other reason Other reason Other reason Other reason

OK

OK

Defined & NOT Defined


Working& NOT Defined
Working& NOT Defined
Working& NOT Defined
Working& NOT
1.14,1.11,1.14,1.25,1.11,1.16
Working
OK

OK

Defined & NOT Defined


Working& NOT Defined
Working& NOT Defined
Working& NOT Defined
Working& NOT
1.11,1.11,1.14,1.25,1.11,1.16
Working
OK

OK

Defined & NOT Defined


Working& NOT Defined
Working& NOT Defined
Working& NOT Defined
Working& NOT
1.22,1.12,1.14,1.16,1.06,1.14
Working
OK

OK

done

Other reason Other reason Other reason Other reason Other


(1.114,1.12),(1.15,1,18),(1.16,1.19)
reason
OK

OK

Other reason Other reason Other reason Other reason Other


A-1.30/1.26,B-1.28/1.29,C-1.25/1.28
reason
OK

OK

Earthing
of all
equipmen
BTS
DC DC
ts(BTS,ID
Earth
DC DC
EGB
connecte
Converter
IGB
U,SMPS's Resistanc
Number connecte
Earthing
d on
working
connecte
Earth
e
of
d to earth
Test:
CRITICAL/
(48 to
d to EGB Bar,BB's [Measure
rectifier
pit
NON24v)
body,PIU,
ment]
CRITICAL
transmiss
ion
IDU's )
YES

YES

OK

OK

Not Done

Non Critical

YES

YES

OK

OK

Not Done

Non Critical

YES

YES

OK

OK

Not Done

Non Critical

YES

YES

OK

OK

Not Done

Non Critical

NO

YES

YES

OK

OK

Done

Non Critical

NO

YES

YES

OK

OK

Done

Criticcal

YES

YES

OK

2
NO

Not Done

YES

YES

OK

OK

Not Done

Non Critical

YES

YES

OK

OK

Done

Criticcal

YES

YES

YES

OK

OK

Done

Non Critical

YES

YES

OK

NO

YES

YES

OK

Not Done

Non Critical

NO

YES

YES

OK

OK

Not Done

Non Critical

NO

YES

YES

OK

OK

Not Done

Non Critical

YES

YES

YES

OK

Not Done

Non Critical

NO

Not Done

NO

YES

YES

OK

OK

Done

Non Critical

N/A

N/A

YES

YES

OK

NOT MESURED

Not Done

Criticcal

NO

N/A

YES

YES

OK

OK

Not Done

Non Critical

YES

YES

OK

Not Done

Non Critical

NO

YES

YES

OK

Not Done

Non Critical

NO

YES

YES

OK

Not Done

Non Critical

OK

NO

NO

YES

YES

OK

OK

Not Done

Criticcal

N/A

N/A

OK

OK

OK

NOT MESURED

Not Done

NON-CRITICAL

YES

YES

YES

OK

NOT OK

Not Done

Non Critical

YES

YES

OK

OK

Not Done

Non Critical

NO
NA

NA

OK

OK

OK

NOT CHEAKED NOT CHECK NON CRITICAL

NA

NA

OK

OK

OK

NOT CHEAKED NOT CHECK NON CRITICAL

YES

YES

OK

Not Done

Non Critical

YES

YES

OK

OK

Not Done

Non Critical

yes

yes

ok

ok

done

Non Critical

NO

YES

YES

OK

NOT OK

Done

Non Critical

NO

YES

YES

OK

NOT OK

Not Done

Non Critical

YES

YES

OK

NOT OK

Not Done

Non Critical

NO

YES

YES

OK

OK

Not Done

Non Critical

NO

YES

YES

OK

NOT OK

Not Done

Criticcal

NO

YES

YES

OK

NOT OK

Not Done

Non Critical

YES

YES

OK

OK

Not Done

Non Critical

NO
NO

NO

NO

YES

YES

OK

NOT OK

Not Done

Non Critical

NO

NO

OK

NOT OK

Not Done

Non Critical

NO

YES

YES

OK

OK

Not Done

Non Critical

NO

YES

NO

OK

OK

Not Done

Criticcal

NO

YES

NO

OK

OK

Not Done

Criticcal

NO

YES

NO

OK

OK

Not Done

Criticcal

NO

YES

YES

OK

OK

Done

Non Critical

NO

YES

YES

OK

NOT MESURED

Not Done

Criticcal

Free
Cooling
FCU
Approx
Unit
working
EB
(FCU)
(Where
Availabilit
installed
DC DG
y (Hours)
(Non AC Installed)
site)

Not Aplicable Not Aplicable

EB
reading

EB Low
Voltage
issue

EB NOT AVAILABLE

No of DG

DG Last
DG
Servicing
Capacity
Date

25 KV

18-Apr-14

Not Aplicable Not Aplicable

FAULTY

NO

25 KVA

18/2/14

Not Aplicable Not Aplicable

NA

NA

NO

20 KVA

2-Nov-14

Not Aplicable Not Aplicable

FAULTY

NO

15 KVA

31/3/14

NO

25 KV

22-Feb-14

Not Aplicable Not Aplicable


YES

YES

775

NO

10 KV

26-Mar-14

NO

NO

FAULTY

NO

15 KV

5-Feb-14

Not Aplicable Not Aplicable

19

YES
YES

YES

NO

NO

Not Aplicable Not Aplicable


YES

Not Aplicable

NO

Not Aplicable

NA

NO

NO

Not Aplicable Not Aplicable

Not Aplicable Not Aplicable

N/A

NO

NA

YES

20 KV

3-Feb-14

40 KV

41736

15-Nov-43

NO

45 KV

25/2/14

NO

15 KV

3-Mar-14

15 KV

16-Mar-14

N/A

NO

15 KV

25/2/14

Faulty

NO

10 KV

25/2/14

NO
FAULTY

N/A

15 KV

NO

30 KV

15/4/14

YES

25 KV

10.10.13

NO

25 KV

1-Apr-14

15 KV

4-Nov-14

EB NOT AVAILABLE

Not Aplicable Not Aplicable

NA

NO

20 KV

15/1/2014

Not Aplicable Not Aplicable

NOT OK

NO

25 KV

13/05/14

Not Aplicable

14

FAULTY

YES

25 KV

22/3/14

Not Aplicable Not Aplicable

N/A

N/A

OK

25KVA

N/A

Not Aplicable Not Aplicable

YES

METER FAULTY

YES

15 KV

NO

NO

NA

NO

25 KV

21-Mar-14

NA

NA

8 HOURS

19465

OK

25 KVA

2-Aug-14

OK

OK

8 HOURS

18144

OK

10 KVA

4-Jun-14
9-May-14

Not Aplicable Not Aplicable

N/A

NO

40 KV

NO

NO

22

45497

NO

30 KV

yes

Not Aplicable

232039

no

10 KV

3-Aug-14

14

NA

NO

25 KV

NA
16-Jan-14

Not Aplicable Not Aplicable

12 HRS

FAULTY

NO

25KVA

Not Aplicable Not Aplicable

NO

Not Aplicable

12

FAULTY

NO

35 KV

Not Aplicable Not Aplicable

10

FAULTY

NO

20 KV

3-Nov-14

2312

YES

15 KV

5-Jan-14

NO

NO

NO

YES

Not Aplicable

Not Aplicable Not Aplicable

15

15 KV

Not Aplicable Not Aplicable

NO

Not Aplicable
5

105

YES

25 KV

Not Aplicable Not Aplicable

18

37143

NO

15 KV

19/5/14

NO

NO

n/a

no

15 KV

3-Jul-14

NO

NO

n/a

no

25 KV

3-Jul-14

NO

NO

n/a

no

15 KV

3-Jul-14

NO

Not Aplicable

NO

15 KV

6-Jan-14

Not Aplicable Not Aplicable

NO

15 KV

4-Jan-14

33140

DG HMR
reading

DG
DG
Automati Battery
on
available

No. of
Battery
Bank

Battery
Bank
MAKE

No of
Cells
Faulty in
Battery
Battery
BB
backup(In
Bank
capacity
Hrs)
[Visual /
informatic
]

FAULTY

NO

YES

Other

600AH

FAULTY

NO

NO

HBL

600

FAULTY

NO

NO

HBL

600

12

FAULTY

NO

NO

Amara Raja

600

HR METER FAULTY

NO

YES

Amara Raja

850AH

10

8271731741

YES

YES

Amara Raja

600AH

FAULTY

NO

YES

Amara Raja

600AH

NO

YES

HBL

NO

YES

Amara Raja

FAULTY

NO

YES

Amara Raja

FAULTY

NO

YES

300*2 AH

600AH

YES

1020 AH

Amara Raja

600AH

faulty

NO

YES

Amara Raja

600AH

Faulty

NO

YES

Other

600AH

N/A

NO

YES

Amara Raja

600AH

NO

YES

Amara Raja

300 Ah

2 Hrs

faulty

NO

YES

Amara Raja

850 AH

YES

YES

Amara Raja

300Ah

FAULTY

NO

YES

Amara Raja

600 AH

1308

NO

YES

Amara Raja

600AH

FAULTY

NO

YES

Amara Raja

600AH

1698783

NO

YES

Amara Raja

510AH

FAULTY

OK

OK

Amara Raja

600 AH

28355

NOT OK

OK

AMARRAJA

600AH

5HRS
1

NO

YES

HBL

300

faulty

NO

YES

Amara Raja

600ah

FAULTY

MANUAL

OK

AMARAJA

OK

600 AH

3HOURS

FAULTY

MANUAL

OK

AMARAJA

OK

300 AH

1 HOURS

FAULTY

YES

YES

Amara Raja

850H

1277971

NO

YES

HBL

1000AH

OK

NO

NO

Amara Raja

ok

600H

23940

NO

YES

HBL

600AH

33651

NO

YES

Amara RAJA

600 Ah

2 Hrs

FAULTY

YES

YES

Amara Raja

600ah

FAULTY

NO

YES

Amara Raja

600AH

FAULTY

NO

YES

Amara Raja

600H

10

NO

YES

YES

YES

Exide

800ah

FAULTY

NO

YES

Amara Raja

600AH

12

FAULTY

NO

YES

Amara Raja

850AH

1690

YES

YES

Amara Raja

600ah

not ok

NO

NO

Amara Raja

600ah

not ok

NO

NO

Amara Raja

600ah

not ok

NO

NO

Amara Raja

600ah

faulty

NO

YES

Amara Raja

600AH

19101

NO

YES

HBL

300AH

BB cells
Battery
bypassed
back Up
or
test done
connecte
in last 6
d
Months
properly

SMPS
Make

SMPS
Capacity

No of
Rectifire
modules

LVD
Setting
(BTS)

No of AC

AC
Capacity

YES

Connected

Delta

3200

YES

Not Aplicable

YES

Delta

3000

47.9

Not Aplicable Not Aplicable

YES

Other

3000

47.9

Not Aplicable Not Aplicable


Not Aplicable Not Aplicable

YES

Delta

2700

47.9

YES

Connected

Emerson

3200W

45

YES

Connected

Linage Power

3000W

OK

Not Aplicable

NO

Connected

Other

2700W

4TR

Not Aplicable

NO

Connected

Other

4000W

NO

Not Aplicable

N/A

Connected

Linage Power

3000W

OK

3 TON

OK

3000W

YES

Not Aplicable

NA

Delta

3000W

1.5

YES

Not Connected Linage Power

NO

Connected

YES

Connected

Other

2700W

46V

Not Aplicable

YES

Connected

Linage Power

18KW

NO

Not Aplicable

N/A

YES

Connected

Linage Power

18KW

NO

Not Aplicable

N/A

NO

Connected

Delta

2700

OK

2TON

NA

YES

Linage Power

2700W

yes

YES

Connected

Linage Power

2700W

YES

YES

Connected

Eltek

3100 W

46.5

OD SITE

YES

Bypass

Delta

2700

CONTROLLER FAULTY

1.5X2

YES

Connected

Delta

2700WATT

BYPASS

Not Aplicable

YES

Connected

Delta

2700W

BYPASSED

NO

OK

Other

6000 W

FAULTY

OK

Connected

ETN

1800W

OK

Not Aplicable Not Aplicable

OK

Not Aplicable Not Aplicable


3TON

NO

Connected

Linage Power

48

Not Aplicable

YES

Bypass

Delta

2700W

NOT OK

2 TON

YES

OK

DELTA

2700W

-45

3 TONE

YES

OK

LINEG POWER

1500W

46 VDC

NA

NA

NO

Connected

Linage Power

4000

OK

Not Aplicable

NO

Connected

Emerson

4000W

NOT OK

YES

Connected

delta

2000w

ok

Not Aplicable

Connected

Eltek

2700

BYPASS

3TONE

2 TON

Yes

Connected

Other

2700W

Working

3TON

YES

Connected

Delta

3200W

Working

Not Aplicable

NA

YES

Connected

Delta

3000WATT

BYPASS

2 TON

NO

Connected

Delta

2700

YES

3TON

NO

Connected

Linage Power

3000w

48

2 ton

NO

Connected

Delta

2700W

-46

Not Aplicable

Connected

Delta

2700W

NO

Not Aplicable

NO

Connected

Linage Power

3000w

48V

Not Aplicable

NO

Connected

Delta

2700W

NO

Connected

Delta

2700W

NO

Connected

Delta

2700W

YES

Connected

Delta

2700

YES

YES

Connected

Delta

2700W

48V

3TON

2-2 TN

Not Aplicable Not Aplicable

Shelter's
Fire
AC
AC
Room
Shelter Shelter/B antistatic Rostek is
Extinguis
working automatio
TS Door
sealed Cleanlines
mat
her
leakage
condition
n
Lock
properly
s
earthing.
Working

OK

OK

OK

Not Aplicable Not Aplicable Not Aplicable

OK

OK

OK

OK

NOT OK

Not Aplicable Not Aplicable Not Aplicable

OK

OK

OK

OK

NOT OK

Not Aplicable Not Aplicable Not Aplicable


NOT OK

NOT OK

OK

OK

OK

OK

NOT OK

OK

NOT OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

NOT OK

NOT OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

NOT OK

OK

NOT OK

NOT OK

OK

OK

OK

OK

OK

OK

NOT OK

NOT OK

OK

OK

OK

OK

OK

OK

OK

NOT OK

OK

OK

OK

OK

OK

NOT OK

OK

OK

OK

OK

OK

OK

OK

OK

Not Aplicable Not Aplicable Not Aplicable Not Aplicable

OK

OK

Not Aplicable Not Aplicable Not Aplicable

OD SITE

NOT OK

OK

OK

OK

OK

OK

NOT OK

OK

NOT OK

OK

OK

OK

OK

NOT OK

NOT OK

NA

OK

NA

OK

NA

NOT OK

OK

NOT OK

NOT OK

OK

OK

NOT OK

OK

OK

Not Aplicable Not Aplicable Not Aplicable Not Aplicable Not Aplicable Not Aplicable Not Aplicable

NOT OK

OK

OK

OK

OK

OK

OK

OK

N/A

OK

NOT OK

NOT OK

NOT OK

OK

OK

NOT OK

NOT OK

OK

NOT OK

OK

NOT OK

OK

OK

OK

OK

OK

MANUAL

NO

OK

OK

OK

OK

NO

NA

NA

NO

OK

OK

OK

OK

NOT OK

NOT OK

NOT OK

NOT OK

NOT OK

OK

OK

NOT OK

OK

ok

not ok

ok

ok

ok

ok

ok

not ok

OK

OK

OK

OK

NOT OK

NOT OK

NOT OK

OK

OK

OK

OK

NOT OK

OK

OK

OK

OK

NOT OK

OK

NOT OK
OK

OK

NOT OK

OK

NOT OK

NOT OK

NOT OK

OK

OK

OK

OK

OK

NOT OK

OK

OK

NOT OK

OK

OK

OK

OK

NOT OK

OK

OK

NOT OK

OK

NOT OK

OK

NOT OK

NOT OK

OK

NOT OK

OK

NOT OK

NOT OK

NOT OK

OK

OK

NOT OK

OK

OK

NOT OK

NOT OK

NOT OK

NOT OK

OK

OK

OK

OK
ok
ok
ok

OK

NOT OK

Not Aplicable Not Aplicable

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

PIU
PIU
automatio
Working
n

Access
Issue If
Any

Owner
issue

Guard
issue

Guard
Contact
Number

Night
Movemen
t Possible
or Not

REMOTE SITE

NO

NO

9504893731

NO

Exact
DG
Issue

ALARM PANEL FAULTY

NOT OK

NOT OK

No

No

No

NO

1 CELL FAULTY

NOT OK

NOT OK

No

No

No

NO

1 CELL BYPASS

NOT OK

NOT OK

1 CELL BYPASS

No

No

No

NO

NO

NO

YES

9973570868

YES STOP SOLINOID FAULTY

OK

OK

OK

NO

NO

8271731741

YES

OK

NOT OK

NO

NO

NO

YES
RUNNING,ANY TIME MAY GET FAULTY
9931088834 24 HRS

OK

NOT OK

NO

NO

NO

OK

OK

NO

NO

8804881709

NOT OK

NOT OKLOW BATTERY BACK UP NO

OK

OK

OK

NOT OK

OK

NOT OK

YES

OK

NOT OK

OK

AUTOMATION FAULT

YES

NO

NO DG NOT RUN BY GUARD

NO

NO

8051605002

YES

Not In Automation

NO

NO

7870863358

NO

Not In Automation

NO

NO

9525885302

NO

DG Working

NO

NO

NO

NA

YES

DG Working

NOT OK

OK

NO

NO

9771979255

YES

AUTOMATION FAULT

NO

NO

NO

8294508350

NO

Alarm Panel

NO

NO

9771450985

YES

NO

NO

NO

8969118364

yes

YES

NO

NO

OK

OK

NOT OK

NOT OK

NOT OK

NOT OK

NO

YES

OK

NOT OK

NO

NO

NO

OK

NOT OK

OK

NO

NO

NOT OK

NOT OK

OK

NO

NO

OK

NOT OK

OK

OK

OK

OK

NOT OK

YES

OK

OK

NO

NO

NA

NA

OK

NA

NA

OK

NOT OK

NOT OK

OK

NOT OK

YES

ok

ok

ok

OK

NO

AUTOMATION NA

NO GUARD

YES

Alarm Panel

9905069259

NO
YES
dg hrm faulty,amf pannel faulty.

N/A

OK

YES

NO

NO

9933471189

YES

OK

OK

8002066170

OK

OK

OK

NA

NO

NO

8507353361

NO

NO

NO

OK

NO

NO

NO

NO

automatin fault

NIGHT ACCESS ISSUE

9162314257

NO
automatin fault

NO

NA

NA

OK

NO

NO

NO

OK

OK

NO

NO

NO

YES

OK

NOT OK

NO

NO

NO

9771740674

YES

NOT OK

NOT OK

N/A

NO

NO

9504778847

NO

NO

NO

NO

NO

OK

OK

NO

NO

NO

ALARM PANEL FAULTY

Alarm Panel

OK

NOT OK

NO

NO

NO 9570414708/9534526242 NO

NOT OK

NOT OK

YES

NO

NO

OK

OK

NO

NO

NO

NO

NO

NO

YES WIRING HARNESS FAULTY

NO

NO

NO

YES WIRING HARNESS FAULTY

NO

NO

NO

YES WIRING HARNESS FAULTY


YES Alternator problem in DG

NOT OK

NOT OK

NO

NO

OK

OK

NO

NO

9006995011

9525373375

RADIATOR L;EAKAGE

NO DG SHELF NOT WORKING

NO

Exact
Battery
Bank
Issue

Exact
SMPS
Issue

Exact
Exact
Shelter
AC Issue
Issue

Exact
PIU
Issue

low voltage issue

Exact
Owner
Issue

Signage
Board
Danger

Signage
Board
Caution

GUARD ISSUE

NO

NO

1 CELL FAULTY

PIU Faulty

NO

NO

1 CELL BYPASS

PIU Faulty

NO

NO

1 CELL BYPASS

PIU Faulty

NO

NO

NO

NO

YES

YES

YES

YES

4 CELL FAULTY
ALARM CARD FAULTY
1 AC Faulty
DOOR ALWAYS OPEN

1 CELL FAUILTY rectifier req


1 CELL FAUILTY1 MODULE REQ
1 AC GAS REQUIRE Leakege

Zero Battery Back1up


MODULE REQ

NO AUTOMATIONNO MAN SITE

NO

NO

YES

YES

YES

NO

YES

YES

YES

YES

NOT ACCESS AT NIGHT YES

YES

NO AC

ENTRY PROBLEM

In Automation
In Automation

no mans Site

OMATION FAULT

NO AUTOMATION

low voltage issue


1 MODULE REQAC not available door open

TOMATION NA
LVD BYPASS

NO AUTOMATION

LVD BYPASSED

ulty,amf pannel faulty.

tomatin fault

Shelter leakage

ALARM CARD FAULTY


AC not available

ALARM CARD FAULTY


AC- MANUAL
15 Min

BYPASS

NO

NO

NO

YES

YES

YES

NO

NO

NO

NO

NO

NO

NO

PIU Faulty

YES

YES

PIU BYBASS

NO

NO

N/A

N/A

NO AUTOMATION

NO

NO

AC- MANUAL
DOOR LOCK FAULTY
NO AUTOMATION

YES

YES

NO

NO

NO

NO

YES

YES

YES

YES

NO

NO

NO

NO

NIGHT MOVEMENT RESTRICTED


NO

NO

NO

NO

NO

NO

NIGHT MOVMENT RESTRIVTED


NO

NO

NO

YES

1 CELL FAUILTY1 MODULE REQ AC NA/FAULTY

M PANEL FAULTY

NO

leakage

NO AUTOMATION
ENTRY PROBLEM

1 AC Faulty
ALARM CARD FAULTY

LVD BYPASS
AC IS NOT RUN BY GUARD

NO AUTOMATION

2 CELL FAULTY
ALARM CARD FAULTY

NO

NO

NO

NO

NO

NO

HARNESS FAULTY

YES

YES

HARNESS FAULTY

YES

YES

HARNESS FAULTY

YES

YES

NO

NO

NO

NO

ELF NOT WORKING

1 CELL FAUILTY

Shelter leakage
COTACTOR FAULTY

SMPS Problem

PIU Faulty

Signage
No of
Transmiss
SDH /
Far end
Board
Operator ion Media PDH [Non [Non EIL Site ID _A Site ID _B TX Alarms
Warning and Name
Name
EIL case]
case]

BSNL,UNINOR,VODAFONE,BSNL
NO
TTSL
3G
NO

AIRTEL,VODA,UNINOR

NO

AIRTEL,VODA,UNINOR TTSL

PDH

PDH

EIL

NAVIN1

TANDWA1

NO

MAHADEVGANJ

MHDEV1

SHB007

OK

BOREO

SHB002

SHB003

OK

42.8

PDH

BAGHA3

BAGHA3

MNGAL1

NO

UNINOR
NO
MASTER ,UNINOR SLAVE
TTSL
NO

2-UNINOR,RELIANCE

YES

TTSL

MicroWave

PDH

TTSL

Not Aplicable

YES

5(UNINOR,AIRCEL,DOCOMO,VODA,IDEA)
NO
TTSL
2

MicroWave

PDH

5( AIRTEL
NO2G,3G, VODA, IDEA,
Microwave
AIRCEL, UNINOR)
cascaded
YES

TTSL

YES
YES
NO

Not Aplicable

Microwave cascaded

HSNPR1

GAUND1

NO

MicroWave

PDH

ARWAL1

SNDES1

ARWAL1

NO

UNINOR,vodafone MicroWave

PDH

NERBI1

CHANDI1

NERBI1

NO

GODDA3

GODDA2

GODDA3

OK

BHABN1

BHABN1

JANIP1

OK

N/A

N/A

N/A

N/A

Aircel,uninor

NO

UWL,AIRCEL

NO

Voda Colo

NO

MicroWave

NO

2 UNINOR DOCOMO

TTSL

NO

TTSL

PDH

MicroWave

Not Aplicable

NO
4(UNINOR,AIRCEL,IDEA,VODA)
TTSL
NOUNINOR,AIRTEL,VODA,IDEA
Microwave cascaded

SDH

SDH

DLT019

DLT015

OK

NO 3,UNINOR,AIRCEL,AIRTEL
MicroWave

PDH

MOKAM3

MOKAM4

MOKAM3

OK

N/A 3UNINOR,RELIANCE,BSNL
ERICSSON
NO

TTSL

Not Aplicable

YES 3-AIRCEL,UNINOR,BSNL
Microwave cascaded

PDH

BIRPU1

MNJHA1

BIRPU1

NO

NO

PDH

NA

NA

NA

NA

PDH

BEG005

BEG012

BEG005

NO

NA

NA

NA

NA

NA

NO
YES

TTSL

2-UNINOR,VODA MicroWave
4

TTSL

YES
5(UNINO,RESIANCE,VODA,IDEA)
NO

1-uninor

MicroWave

NO

2(UNINOR,BSNL)

EIL

NO3,UNINOR,BSNL,VODAFONE
TTSL
NO

VODAFONE,UNINOR EIL MW

NO

2(UNINOR,BSNL)

EIL

NO

TTSL

PDH

Not Aplicable Not Aplicable Not Aplicable Not Aplicable Not Aplicable

TTSL
YES 3(aricel,uninor,docomo) TTSL

N/A
Not Aplicable

N/A

N/A

N/A

N/A

NO

1(UNINOR)

TTSL

NO

TTSL

PDH

CHK002

NA

NA

NA

NO

2(uninor,Voda)

Voda Colo

Not Aplicable

N/A

N/A

N/A

N/A

YES

TTSL

YES

Microwave cascaded

YES

TTSL

NO

Microwave cascaded

NO

MicroWave

PDH

Not Aplicable

PERSA1
HIL001

UW_BIHAR_2788
UW_BIHAR_1773

NO ALARM
NO

RX Level

TX Power

-42

18

41.1

12

10
40.1

Radio
Type (A
side)

AMM KIT
(A Side)

AMM KIT
(BSide)

MMU (A
Side)

MMU (B
Side)

RAU2 X18/12 RAU2 X 18/16

AMM 2P B

AMM 2P B

MMU 2D

MMU 2D

RAU2X 18/12 RAU2X 18/16

2P

2P

MMU2D

MMU2D

2P

6P

MMU2C

MMU2C

NPU3

18/16

2P B

2P B

MMU 2C

MMU2C

RAU2X 18/12 RAU2X 18/16


8

Radio
Type (B
Side)

18/16

43.5/42.6

8DBM

X18/16

X18/12

2P

2P

MMU 2D

MMU2D

37.3dbm

17dbm

rau2x18/16

rau2x18/12

2p kit

2p kit

mmu2d

mmu2d

33.9dbm

5dbm

ODUXX412

ODUXX410

NA

NA

NA

NA

30.7

12

RAU2XU 18/16 RAU2XU 18/12

6P

2P

MMU 2E

MMU 2E

42.9

RAU2 X 18/12 RAU2 X 18/16

2P

20

MMU2C

MMU2 C

N/A

N/A

N/A

N/A

N/A

N/A

47.3

18

2P

2P

MMU2 E 155

MMU2 E 155

37.9

18

RAU 2 18/16

RAU 2 18/12

6P

6P

MMU 2E

MMU 2E

42.3

10

RAU2X 18/12 RAU2X 18/16

2P

6P

MMU 2D

MMU2D

NA

NA

NA

NA

NA

NA

NA

NA

33.1

RAU2x23/91

RAU2x23/95

AMM2P

AMM2P

MMU2D

MMU2D

NA

NA

NA

NA

NA

NA

NA

NA

N/A

N/A

RAU2 X 18/12 RAU2 X 18/16

Not Aplicable Not Aplicable Not Aplicable Not Aplicable Not Aplicable Not Aplicable Not Aplicable Not Aplicable
N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

NA

NA

NA

NA

NA

NA

NA

NA

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

2P

MMU2D

MMU2D

6P KIT
41.6

12

RAU2X 18/16 RAU2X 18/12

2P

NPU

Tx
connecte
d on
TX/RX
MW
CRITICAL/
Frequenc Groundin
NONy
g
CRITICAL
in SMPS
{Both EIL
- Non EIL]
OK

Punch
Points
If any

GUARD
Critical
USUALLY NOT STARTS THE DG ON TIME

NPU3

18112/19122

YES

Critical

NPU3

18112/5/19122.5

OK

Non Critical
NEED DG SERVICING

18112.5/19122.5

OK

Non Critical

NPU3

19122.0/18112.0

OK

NPU 3

19122.5/18112.5

OK

Critical
EXT. ALARM NOT THROUGH IP END

NPU3

19122.5/18112.5

OK

Critical

NA

19122.5/18112.5

OK

Critical remarks-Alcatel IDU

NPU 3

19122.5

OK

Alarm
CRITICAL
MUX not present, DG AUTOMATION FAIL

OK

EXTERNAL
Critical
ALARM NOT PATCHED FROM INFRA END

NPU 2B 18112.50/19122.50
N/A

N/A

Non Critical

N/A

OK,

Critical ALARM MUX FAULTY


AC OFF, SHELTER DOOR OPEN , DG AUTOMATION FAULT
Non Critical

NPU3

18112

OK

NPU 3

19222.5/18212.5

NPU3

18112.5

OK

Non Critical

B.B IS ZERO

NA

NA

NA

NA

OK

NPU3

21266/22498

OK

NON CRITICAL

OK

NA

NA

NA

NA

OK

Non Critical WATER LEAKAGE


Critical

Critical

Non Critical
Not Aplicable Not Aplicable Not Aplicable Not Aplicable
N/A

N/A

N/A

N/A

N/A

ROSTEK NOT SHEALED,WATER


Critical
LOBBING PROBLEM,DG RADIWATER PROBLEM
EX NA
ALARM PENDING
NA / EGB NOT CONNECTED
NA
TONA
EARTH PIT/ EARTHING NOT AVL FROM ATC END/SMPS MODULE URGENTLY REQD
N/A

N/A

N/A

N/A
ex alarm pending from ip end
ex alarm pending from ip end
ex alarm pending from ip end

NPU3
NPU3B

OK

Critical

19122.5/18112.5
KNOP FAN
OK SWITCH OFF
Critical
BY GUARD, EXTERNAL ALARM PENDING BY INFRA END

ODULE URGENTLY REQD