Sie sind auf Seite 1von 4

R

OPTEVA 520c REAR LOAD VESTIBULE


CASH DISPENSER (INTERIOR USE ONLY)
1

4 HIGH WITH 13mm (2") SAFE


CALL 1-800-999-3600

CONSULT WITH DIEBOLD INSTALLATION/SERVICE


BRANCH FOR ADDITIONAL DETAILS AND INFORMATION.
PLEASE SEE PLANNING AND SITE PREPARATION GUIDE
(
DI
M ENSI
ONS I
NI
NCHES)

TP-821341-001.

747
(2-5")
152

442

152

(6")

(1-5")

(6")

TOP FUNCTION KEY


RECEIPT PRINTER

765

"
)

150mm (5") MAXIMUM

MOTORIZED CARD
READER

KEYPAD
(TOP ROW)

WALL THICKNESS IN
AREA OF UNIT

ADVANCED FUNCTION

(
2
-6

DI
M ENSI
ONS I
N MI
LLI
M ETRES

L877544

HEADPHONE
JACK (ADA)

DISPENSER

"
)

62

(
2

THI
RD ANGLE
PROJECTI
ON

CONSUMER BAR
CODE SCANNER

429 W.O.

30
(1")

(1-4")

30
(1")

489

TOP
FUNCTION
KEY
HEIGHT DEPTH

(1-7")

1158

FASCIA

(3-9")

PLAN VIEW

243
(9")

KEY PAD
(TOP ROW)

RECEIPT
PRINTER

CONSUMER
BAR CODE
SCANNER

HEADPHONE
JACK (ADA)

ADVANCED

MOTORIZED

FUNCTION
DISPENSER

CARD
READER

HEIGHT DEPTH HEIGHT DEPTH HEIGHT DEPTH HEIGHT DEPTH HEIGHT DEPTH
951

203
(8")

(3-1")

922
3-0")

173
(6")

910
(2-11")

102
(4")

751
(2-5")

37
(1")

800
(2-7")

87
(3")

HEIGHT DEPTH
952
(3-1")

HEIGHT - FROM BOTTOM OF SAFE


DEPTH - FROM FRONT EDGE OF BEZEL

NOTE #2
776mm (30") MAXIMUM HEIGHT TO BOTTOM OF WALL FOR
CANADIAN STANDARDS ASSOCIATION (CSA) REQUIREMENTS.
769 (31") MAXIMUM HEIGHT TO BOTTOM OF WALL OPENING FOR
AMERICANS WITH DISABILITIES ACT (ADA) REQUIREMENTS.
826mm (32") MAXIMUM HEIGHT TO BOTTOM OF WALL OPENING FOR
MINIMUM SERVICE AREA

CENTRE FOR ENVIRONMENTS (CAE) REQUIREMENTS.

EXTERIOR ELEVATION

(
6"
)

152

(
1

765
(2-6")

VERTICAL SECTION

(
0"TO (
5

"
)
1767

(
5
-9

"
)
607 SAFE
(1-11")

(
5
-0

1538
"
)
158
(6")

(
2
-4

720
(5")

"
)LEVELI
NG

"
)
(
2
-6

785 W.
O.

33
149

MAXIMUM WALL
INSIDE FLOOR LEVEL MUST BE THE SAME AS OUTSIDE
SIDEWALK LEVEL FOR OPTIMUM ACCESS. IF INSIDE
FLOOR IS HIGHER OR LOWER THAN OUTSIDE, DIMENSION
FOR LOCATION WALL OPENING WILL HAVE TO BE ADJUSTED
ACCORDINGLY AND OPTIMUM ACCESS REQUIREMENTS WILL
NOT BE MET.

"
)

79
"
)
(
0

22
SEE NOTE #2

NOTE #1

(
3

"
)

210

(
8
"
)

O.
785 W.

(
2
-6
"
)

797 SHOWN

(
2
-7

"
)

A
1018 FASCI

(
3
-4

313
(1-0")

0 TO 150m m

FI
LE NO.177544 REV.0

SEE WALL OPENING DETAIL


FOR RECOMMENDED CLEARANCE
REQUIRED AROUND FASCIA.

WI
TH SI
GNAGE LI
GHT PANEL

"
)
(
7
"
)
(
2
-8

182
A
835 FASCI

WI
TH SI
GNAGE LI
GHT PANEL

"
)

FASCI
A
1018

OPTIONAL CONSUMER BAR


CODE SCANNER (SEE
CAUTION LABEL)

214
(8")

"
)

(3")

489
(1-7")

(
3
-4

"
ALL DI
M ENSI
ONS AND DESI
GN CRI
TERI
A
SUBJECT TO CHANGE W I
THOUT NOTI
CE"

PAGE 1 OF 4

INSTALLATION/SERVICE AREA
79

213
(8")

POWER REQUIREMENTS

CONDUIT AND JUNCTION BOX REQUIREMENTS


25mm (1") METAL CONDUIT FROM ALARM CONTROL CABINET
JUNCTION BOX TO 102mm (4") SQ. X 54mm (2") DEEP JUNCTI0N

THE CASH DISPENSER REQUIRES A SINGLE-PHASE, THREE-WIRE


UNSWITCHED POWER RECEPTACLE. WIRING TO THE RECEPTACLE MUST
INCLUDE A THIRD-WIRE EARTH GROUND (CONDUIT GROUND IS NOT
ACCEPTABLE). THE CASH DISPENSER WILL PROVIDE A POWER CORD WITH
A COUNTRY SPECIFIC POWER PLUG. THE POWER SUPPLIED MUST BE AS
SPECIFIED BELOW.

BOX (ALL BY OWNERS E.C.). DIEBOLD TO PROVIDE FLAT COVER


WITH TAMPER SWITCH.
OWNERS E.C. TO RUN 19mm (") LIQUID TIGHT FLEX METAL

CONDUIT OR 19mm (3#4") RIGID CONDUIT FROM JUNCTION BOX


TO CABLE CONNECTION PLATE.

100-127 VAC (+6%, -10%) AT 60 (1%) Hz, SINGLE-PHASE


200-240 VAC (10%) AT 50 (1%) Hz, SINGLE-PHASE
200-240 VAC (10%) AT 50 (1%) Hz, SINGLE-PHASE
POWER TO THE CASH DISPENSER MUST BE PROTECTED BY A SAFETY
QUICK-DISCONNECT DEVICE TO BREAK LINE VOLTAGE (SUCH AS A

OWNERS E.C. TO SUPPLY COMPATIBLE RECEPTACLE FOR COUNTRY

(
DI
M ENSI
ONS I
NI
NCHES)

DI
M ENSI
ONS I
N MI
LLI
M ETRES

100-127 VAC (+6%, -10%) AT 50 (1%) Hz, SINGLE-PHASE

19mm (") METAL CONDUIT AND UNSWITCHED ELECTRICAL SUPPLY


TO 102mm (4") SQ. X 54mm (2") DEEP JUNCTION BOX WITH
RECEPTACLE WITHIN 2210 (7-3") OF SIDE CONNECTING PLATE.
BOTTOM CONNECTION MUST BE COMPENSATED ACCORDINGLY
(ALL BY OWNERS E.C.) (SEE POWER REQUIREMENTS).

SPECIFIC PLUG-IN CONNECTOR SUPPLIED WITH UNIT. POWER CORD


LENGTH 2210mm (7-3") FROM SIDE OF UNIT.

CIRCUIT BREAKER AT THE ELECTRICAL SERVICE PANEL. THE QUICKDISCONNECT DEVICE (OR CIRCUIT BREAKER) MUST TURN OFF THE
LINE VOLTAGE AT THE FOLLOWING AMPERAGE.

JUNCTION BOXES MUST BE LOCATED WITHIN 2210mm (7-3") OF

THE MODULE BULK POWER SUPPLY AND PROCESSOR POWER SUPPLY


WILL PROVIDE POWER CONDITIONING TO PREVENT THE TERMINAL FROM
MALFUNCTIONING DUE TO SHORT-TERM AC POWER FLUCTUATIONS AS
OUTLINED IN EN6100-4-11.

CONNECTING PLATE. (LENGTH OF ELECTRICAL POWER CABLE


PROVIDED WITH UNIT). LOCATE IN AN EASILY ACCESSIBLE AREA.

POWER USAGE:

NOTE:

BOXES CAN BE FLUSH MOUNTED WITH CONCEALED CONDUIT FOR


NEW CONSTRUCTION OR BOXES CAN BE SURFACE MOUNTED WITH
EXPOSED CONDUIT FOR EXISTING CONSTRUCTION.

PHYSICAL SECURITY:
THE SECURITY SAFE MEETS THE BANK PROTECTION ACT 82 STAT 295,
12 USC 882, AND MEETS THE ATTACK TEST PER UL 291-15. THE SAFE
DOOR HAS A POSITIVE RELOCKING FEATURE. THE SAFE DOOR IS
CONTROLLED BY A GROUP 2 COMBINATION LOCK WITH OR WITHOUT
KEYLOCKING DIAL CAPABILITY OR OPTIONAL ELECTRONIC LOCK.

WITH
HEATER

WITH
HEATER

190 WATTS

790 WATTS

250 WATTS

850 WATTS

TRANSACTION (DISPENSE
OR BULK NOTE) IN

285 WATTS

885 WATTS

345 WATTS

945 WATTS

PROGRESS

CONFIGURATION:
1 PROCESSOR, COLOR LCD CONSUMER DISPLAY, MOTORIZED CARD READER,
JOURNAL PRINTER, RECEIPT PRINTER, AND FOUR-CASSETTE DISPENSER

2
THE UL-LISTED SAFE IS EQUIPPED WITH A BASIC ALARM SENSOR
PACKAGE. THE BASIC PACKAGE INCLUDES A SAFE DOOR OPEN SWITCH,
ALARM SHUNTING SWITCH, AND RATE-OF-RISE HEAT SENSOR.

PROJECTI
ON

IDLE (NO TRANSACTION)

ALARM PROTECTION:

PROCESSOR, SUNLIGHT VIEWABLE LCD CONSUMER DISPLAY, MOTORIZED


CARD READER, JOURNAL PRINTER, RECEIPT PRINTER, AND FOURCASSETTE DISPENSER.

HEAT OUTPUT CONFIGURATION:

SIGNAL CABLE RUN CONSTRAINTS:


THE FOLLOWING CHART ITEMIZES THE PHYSICAL SPACING REQUIREMENTS
OF THE SIGNAL CABLE RUN WITH RESPECT TO OTHER POWER AND
ELECTRICAL EQUIPMENT CABLE RUN.

648 BTU/HR IDLE WITHOUT HEATER-2696 BTU/HR IDLE WITH HEATER


972 BTU/HR DISPENSE WITHOUT HEATER- 3020 BTU/HR DISPENSE
WITH HEATER.
853 BTU/HR IDLE WITHOUT HEATER-2902 BTU/HR IDLE WITH HEATER

1177 BTU/HR DISPENSE WITHOUT HEATER- 3225 BTU/HR DISPENSE


WITH HEATER.

OPERATING ENVIRONMENT:

POWER OF ELECTRICAL RUN


TYPE OF ELECTRICAL RUN
FLUORESCENT, NEON OR INCANDESCENT
LIGHTING FIXTURES
UNSHIELDED POWER LINE OR
ELECTRICAL EQUIPMENT

BELOW 2 KVA

2-5 KVA

ABOVE 5 KVA

127mm (5")

127mm (5")

127mm (5")

127mm (5")

305mm (1-0")

610mm (2-0")

SAFE LOCATION

FASCIA LOCATION

UNSHIELDED POWER LINES OR


ELECTRICAL EQUIPMENT WITH
SIGNAL CABLES INCLOSED IN

64mm (2")

152mm (6")

305mm (1-0")

30mm (1")

76mm (3")

152mm (6")

10C TO 38C (50F TO 100F)


RELATIVE HUMIDITY (NON-CONDENSING)
20 TO 80% AT 32C (90F)
20 TO 55% AT 38C (100F)
-34 C TO 54 C (-30 F TO 130 F)
RELATIVE HUMIDITY 15 TO 100%

WEIGHT OF UNIT:

GROUNDED CONDUIT
POWER LINES IN GROUNDED CONDUIT
WITH SIGNAL CABLES IN GROUNDED
CONDUIT

392kg (864 LBS.)

(1-")

(2")

262

165

(10")

CAUTION LABEL

176

(6") (6")

37
(1")

"
)

"
)
(
3

79
"
)

55
262
(10")

DIODE LASER
1 mW MAX OUTPUT at 635-670 nm
CLASS II LASER PRODUCT
Complies with 21 CFR 1040.10 and 1040.11

(
2

529

(
1
-8

547
"
)

95

(
1
-9
55

(2")

DO NOT STARE INTO BEAM

(
1

"
)
39

LASER RADIATION

(
3

"
ALL DI
M ENSI
ONS AND DESI
GN CRI
TERI
A
SUBJECT TO CHANGE W I
THOUT NOTI
CE"

"
)

(2")

87

57

(
3

315

12

69

( "
)

RELATIVE CARE IS REQUIRED WHEN INSTALLING SIGNAL CABLES IN CONDUITS, UNLIKE


POWER AND LIGHTING CABLE, SIGNAL CABLES HAVE CONDUCTORS AND LIGHT INSULATION
AND WILL NOT WITHSTAND AS MUCH STRAIN IN INSTALLATION.

"
)

PAGE 2 OF 4

SIGNAL CABLE INSTALLATION CONSTRAINTS:

Certified in accordance with EIC 60825-1

71
(2")

4
2
FI
LE NO.177544 REV.0

THI
RD ANGLE

MACHINE STATUS

143
(5")

425
(1-4")
38
(1")
606 SAFE
(1-11")

INTERIOR ELEVATION

VERTICAL SECTION

OPTEVA 520c REAR LOAD VESTIBULE


CASH DISPENSER (INTERIOR USE ONLY)

4 HIGH WITH 13mm (2") SAFE


CALL 1-800-999-3600

WALL OPENING DETAIL

DI
M ENSI
ONS I
N MI
LLI
M ETRES

(
DI
M ENSI
ONS I
NI
NCHES)

THI
RD ANGLE

PROJECTI
ON

REQUIRED FOR WALL


THICKNESS OVER
150mm (5")

747
(2-5")
159
(6")

429 W.O.
(1-4")

159
(6")

429 W.O.

30
(1")

(1-4")

30
(1")

NOTE #2

PLAN VIEW

776mm (30") MAXIMUM HEIGHT TO BOTTOM OF WALL FOR


CANADIAN STANDARDS ASSOCIATION (CSA) REQUIREMENTS.
769 (31") MAXIMUM HEIGHT TO BOTTOM OF WALL OPENING FOR
AMERICANS WITH DISABILITIES ACT (ADA) REQUIREMENTS.
826mm (32") MAXIMUM HEIGHT TO BOTTOM OF WALL OPENING FOR
CENTRE FOR ENVIRONMENTS (CAE) REQUIREMENTS.

*PROVIDE VERTICAL AND HORIZONTAL

FLAT PLUMB SURFACE AROUND WALL


OPENING FOR PROPER INSTALLATION
OF THE CASH DISPENSER.

150mm (5") MAXIMUM


WALL THICKNESS IN
AREA OF UNIT

PAGE 3 OF 4

*540
(1-9")

*55

"
)

O.
785 W.

(
2
-6

892

(
2
-11

"
)

"
)
"
)
(
2
-6

(
2
O.
785 W.

60
48

(
1 "
)

"
)
1068

"
)

186

"
)

(2")

(
9

236

(1-4")

(
3
-6

SEE NOTE #2

"
)

797 SHOWN

(
2
-7

SEE NOTE #2

"
)

797 SHOWN

(
2
-7

"
ALL DI
M ENSI
ONS AND DESI
GN CRI
TERI
A
SUBJECT TO CHANGE W I
THOUT NOTI
CE"

FI
LE NO.177544 REV.0

429 W.O.

(2")

(
7

*55

NOTE #1
INSIDE FLOOR LEVEL MUST BE THE SAME AS OUTSIDE
SIDEWALK LEVEL FOR OPTIMUM ACCESS. IF INSIDE
FLOOR IS HIGHER OR LOWER THAN OUTSIDE, DIMENSION
FOR LOCATION WALL OPENING WILL HAVE TO BE ADJUSTED
ACCORDINGLY AND OPTIMUM ACCESS REQUIREMENTS WILL
NOT BE MET.

EXTERIOR ELEVATION

149
MAXIMUM WALL
(5")

VERTICAL SECTION

NOTES:
1- UNIT COMES WITH (4) LEVELING LEGS. MUST BE REMOVED WHEN ANCHORING UNIT TO
THE FLOOR.
2- FOR ADDED SECURITY, IT IS RECOMMENDED THAT THE SAFE BE SECURED TO THE
FLOOR WITH ANCHOR BOLTS (M20 (") RECOMMENDED - NOT SUPPLIED WITH THE

442

UNIT). A CONCRETE OR MASONRY FLOOR AT LEAST 152mm (6") THICK IS RECOMMENDED.


MOUNTING HOLES ARE SHOWN IN PLAN/SECTION VIEW FOR SIZE AND LOCATIONS.

118

2
(
1
-11 "
)

607

417

"
)
453

(
1
-5

"
)
(
1
-4

OPENING FOR POWER CORD


AND DATA CABLES
(SIDE ENTRY)

36

POWER CABLE PLATE

(
1 "
)

99

(
3

1
2

"
)

426

(
1
-4

"
)

"
)

29mm (1") DIA. HOLE FOR


ALARM CABLES (SIDE ENTRY)

(
1

38

(
4

(
5

(
DI
M ENSI
ONS I
NI
NCHES)

1
2

RECOMMENDED ANCHOR BOLT SIZE IS FOR REFERENCE ONLY AND THERE MAY BE
REQUIRED INSTITUTION OR COUNTRY SPECIFIC SECURITY NEEDS.

"
)

(1")

(
3

(1-2")

"
)

(1")

90

36

"
)

371

143

36

DI
M ENSI
ONS I
N MI
LLI
M ETRES

(1-5")

PLAN/SECTION
PROJECTI
ON

2 (4) 22mm (") DIA. FLOOR MOUNTING HOLES

RECOMMENDED SERVICE AREA

NOTE:
MINIMUM SERVICE AREA

PAGE 4 OF 4

ALL ELECTRICAL AND DATA CABLES


MUST ENTER UNIT IN THIS AREA

216

SHOWN IS THE MINIMUM/RECOMMENDED AREA REQUIRED FOR INSTALLATION AND


SERVICE. DIMENSIONS SHOWN MAY BE INCREASED WHEREVER POSSIBLE TO
IMPROVE INSTALLATION AND SERVICE ACCESS. USE OF ANY AREA LESS THAN THE
RECOMMENDED AREA MAY RESULT IN AN INCREASE IN INSTALLATION AND SERVICE
TIME. CONSULT WITH DIEBOLD INSTALLATION/SERVICE BRANCH FOR SPECIAL
BUILDING CONDITIONS.

912

1209

(2-11")

(3-11")

442 SAFE

254

366

442

404

(10")

(1-2")

(1-5")

(1-3")

152

"
)
(
3

86

PLAN VIEW
MINIMUM SERVICE AREA

51
(2")

"
)

1041
(3-5")

51
(2")

300

(
1
-9

300
(11")

(
2
-6

"
)

"
)
765

(
6
-6

1997

442 SAFE
(1-5")

556

300
(11")

(
6"
)

676

(
2
-2

"
)
(
3
(
6"
)

152

"
)
(
2
-6

51
(2")

"
)

51
(2")

(
1
-9

765
556

1997

"
)

86

(
2
-2

676

"
)

(1-5")

"
)

(8")

(
6
-6

"
ALL DI
M ENSI
ONS AND DESI
GN CRI
TERI
A
SUBJECT TO CHANGE W I
THOUT NOTI
CE"

FI
LE NO.177544 REV.0

THI
RD ANGLE

1 (4) 14mm (") DIA. LEVELING LEG HOLES

(11")

442 SAFE
(1-5")

300
(11")

1041
(3-5")

PLAN VIEW
RECOMMENDED SERVICE AREA

Das könnte Ihnen auch gefallen