Beruflich Dokumente
Kultur Dokumente
Series 300
Valves
Series 300 Valves
Product Catalogue
Waterworks
Dorots valves are specially designed to comply
with all the demands of Waterworks systems such
as: Pressure management, Low flow regulation,
Leakage prevention, Pump control, Level control,
Surge prevention, Sewage and Water treatment.
Irrigation
Dorot is a leader in Automatic Control valves for
irrigation applications: Drip Irrigation, Greenhouses,
Turf and Landscaping. The innovative state of the
art products are made of a variety of materials
such as: Cast Iron, Ductile Iron, Steel, Stainless
Steel, Bronze, Polyamide and uPVC.
Fire Protection
Dorot offers a variety of valves for fire protection
applications with UL Approvals.
Edition 06/2012
Contents
General Information
Overview
Features
Engineering Data
Technical Specifications
Materials
10
Cavitation Data
11
12
13
14
15
Components
16
17
17
Pressure Regulating
17
17
18
19
20
21
23
Edition 06/2012
General Information
Overview
DOROTS 300 Series, the latest line of state-of-the-art globe type automatic control valves, is designed to withstand even
the most demanding requirements of water system control. The experts at DOROT developed this technically-advanced
line with capabilities, far beyond any other valve on the market.
This Engineering Data guide will asist the reader in the selection of the optimal DOROT Series 300 valve.
Features
Air release nut
Suspension hook
Fully supported Diaphragm
Spring
Diaphragm discs
Seal discs
Seat
Centering guide
4
Edition 06/2012
Engineering Data
Technical Specifications
Parameter
Connections
Standard
Model 30:
Models 31, 32:
Pressure range
0.5 16bar
7 250 psi
0.5 25 bar
7 360 psi
80C / 180F
Optional
95C / 200F
Materials
Part
Standard
Optional
Spring
SST 302
Diaphragm
NBR
Seals
NBR (Buna-N)
EPDM
Viton
Coating
Brass
SST 304
SST 316
Copper
SST 316
Note: The Dorot S-300 valves in all sizes, meet the USA amendment for reducing lead in drinking water marked as
S.3874 dated 01.05.2010.
5
Edition 06/2012
Engineering Data
Closed Mode
Closed Mode
Separation
Disc
Separation
Disc
Control
Device
Control
Device
Closed Mode
D chamber - Closed Mode
Open Mode: The
control device releases the pressure
from the top control
chamber.
D chamber
- Closed Mode
The seal assembly is forced to the open position by the
pipeline pressure, allowing flow through the valve.
Open Mode
Opened Mode
Open Mode
Control
Device
Control
Device
Opened Mode
6
Edition 06/2012
CM
MY
CY
CMY
CM
MY
CY
CMY
Engineering Data
Modulating Mode
Modulating Mode
General
Modulating Mode
Positioning
the seal a short
distance (less than 1/4 of the Regulation at high pressures difference
General
Modulating
Mode
Modulating
in standard
(single
chamber)
Modulating
modemode
in standard
(single
chamber)
valves. so the water stream enters the cylinder from its external
valves
Closed
Closed
Closed
Closed
Fully Open
Closed Valve
FullyOpen
Open
Fully
Fully Open
Cavitation energy
dissipation area
Regulating
Regulating
Fully-opened
Valve
Regulating
Regulating
7
Edition 06/2012
Engineering Data
Regulating Valve
Regulating Valve
Closed Valve
Closed Mode
Closed Mode
Open Mode
Opened Valve
Open Mode
8
Edition 06/2012
Engineering Data
C
3-WayControl
Control Device
Device
3-Way
Some
of theprevents
3-way control
devices
third
mode as
well, which
inflow or
outflowhave
fromathe
control
well,
whichsoprevents
inflow
or outflow
the control
chamber,
that the main
valve
remains from
fixed when
the
chamber,
thatmode.
the main valve remains fixed when the
device is so
in this
The 3-way
mode
is used in on-off valves or when the
device
is in this
mode.
regulating
valve
fully
open,
in order
to obtain
This
mode is
usedis in
on-off
valves
or when
thespecific
regulating
operating
conditions.
Once
in
position,
there
is nooperating
water
valve is fully open, in order to obtain specific
flow
through
the
control
chamber.
conditions. Once in position, there is no water flow through
The 3-way control circuit may open the main valve
the
control chamber.
entirely, creating minimum head loss.
The
3-way control device may open the main valve entirely,
The 3-way control device must be used when external
creating
minimum
loss.
media (not
pipelinehead
water)
is used to control the valve,
The
3-waythe
control
device
must
be used
when external media
or when
control
media
is dirty
or abrasive.
(not pipeline water) is used to control the valve, or when
the control media is abrasive.
CM
MY
CY CMY
Proportional Pressure
Proportional
PressureReducer
Reducer
No
device isis needed.
needed.
Noother
other control
control device
Separation
Disc
Closed Valve
Closed Mode
Closed Valve
Opened Valve
Open Mode
Regular Flow
Open Mode
Open Valve
9
Edition 06/2012
Engineering Data
SaughtonDorot
Hall under
10 0mm
DOROT
300Pilot
S eriesControl
CX Pilot Control
100mm
300
Series
CX
Pressures logged
Pressures
loggedatat1 1
Minute Intervals
Minute
Intervals
Flow
Flowlogged
loggedatat1515Minute
Minute
intervals
intervals
80
70
8
7
6
5
40
4
Flow Litre/sec
50
30
3
20
Flow Litre/sec
Pressure
Metres
Pressure Metres
60
10
0
9.2.2001
10.2.2001
11.2.2001
12.2.2001
Inlet Pressure
Pressure
Inlet
13.2.2001
Outlet Pressure
Pressure
Outlet
14.2.2001
15.2.2001
0
16.2.2001
Flow
Flow
SERIES 300
CHARACTERISTIC
CURVE
Comparison
of different
seal structures
100
90
80
Valve opening
70
60
50
40
30
20
10
Unstable regulation
regulation zone
Unstable
zone
0
0
0.1
0.2
LTP
(S-300
Valve)*
LTPDesign
Design
(S-300
Valve) *
0.3
0.4
V-Plug
V-Plug
0.5
Kn
Kv
0.6
U-Plug
U-Plug
0.6
0.7
0.8
1.0
LTP Design
Flat-Disk
plug (S-300 Valve)
** Independent
report
data
source
Independentlaboratory
laboratory
report
data
source
10
Edition 06/2012
Engineering Data
Cavitation Data
Inlet
Inlet pressure
pressure
psi mwc
360 250
340
240
230
320 220
300
210
200
260 180
240
Noisy
Noisy
Operating
Operating
Destructive
Destructive
Cavitation
Cavitation
280 190
170
160
CaseCase II
2
220 150
200
180
140
Case-1I
Case
130
120
160 110
140
CaseCaseIII
3
100
120
100
80
60
40
20
90
80
Safe
Safe
Operating
Operating
Conditions
conditions
70
60
50
40
30
20
10
Outlet
Outlet
pressure
pressure
0
10
10
20
20
30
40
30
50
40
60
50
70
80
60
90
70
100
110
80
mwc
psi
Cavitation Chart
Limits of operating conditions
The chart above sets the safe limits for valves that are supposed to operate at a considerable pressure differential.
Such conditions generate noise and possible cavitation damages to the valve body.
How to use the chart:
i. Determine the maximal dynamic pressure that may be applied in the inlet of the valve.
ii. Draw an horizontal line from the pressure scale at the left side of the chart
iii. Find the requested outlet pressure in the pressure scale at the bottom of the chart.
iv. Draw an upward line at this point.
v. The intersection of the two lines defines the cavitation characteristics of the valve operation.
- In the case that it falls in the RED zone (case I)- the valve may be damaged in a fairly short time.
- In the case that it falls in the YELLOW zone (case II)- the valve may generate a noise that exceeds 80db.
- In the case that the intersection is within the GREEN zone (case III)- the valve will perform safely and quietly
General remark: The cavitation and noise data are based on tests done by the Utah State University, US, and Delft Hydraulic Laboratories, Holland.
11
Edition 06/2012
Engineering Data
H
AH
40 (11/2)
50 ( 2)
mm inch mm inch
L
230 91/16 230 91/16
H
185 75/16 185 75/16
h**
140 51/2 140 51/2
170 611/16
6
W
153
R
82.5 31/4 82.5 31/4
Weight Kg/Ibs*
12 / 26
12 / 26
Vol.control
0.1
/
0.02
0.1
/ 0.02
chamber lit/gal
Valve Size
65 (21/2)
mm inch
292 121/2
185 75/16
140 51/2
170 611/16
92.5 35/8
13 / 29
80 (3)
mm inch
310 123/16
230 91/16
170 611/16
200 77/8
100 315/16
22 / 49
100 (4)
mm inch
350 133/4
240 97/16
180
7
235 91/4
110 45/16
37 / 82
150 (6)
mm inch
480 187/8
330 13
230
9
330 13
142.5 55/8
80 / 176
0.1 / 0.02
0.3 / 0.08
0.7 / 0.2
1.5 / 0.4
200 (8)
mm
inch
L
600 235/8
H
390 153/8
h**
300 1113/16
W
415 165/16
R
172.5 63/4
Weight Kg/Ibs*
157 / 346
Vol.control
4.3 / 1.1
chamber lit/gal
250 (10)
mm
inch
730 283/4
520 201/2
390 151/4
525 2011/16
81/16
205
245 / 540
450 (18)h
mm
inch
L
1200 471/4
H
855 33H5/8
h**
600 235/8
W
850 337/16
3
/16
R
310 12R
Weight Kg/Ibs* 945 / 2083
Vol.control
50 / 13.2
chamber lit/gal
500 (20)
mm
inch
1250 493/16
855 335/8
600 235/8
850 337/16
357.5 141/16
980 / 2160
Valve Size
300 (12)
350 (14)
mm
inch
mm
inch
h
850 337/16 H 980 389/16
635
635
25
25
450 1711H/16 450 1711/16
24
610
24
610
9 R 272 1011/16
230
405 / 893
510 / 1124
R
9.7 / 2.6
50 / 13.2
Angle Type
18.6 / 4.9
R
h
L
L
h
TH
AW
TW
TW
AB
AB
TR
AL
TL
AL
TL
TW
TW
AB
AB
TL
250 (10)
mm inchTW
585
23
832 323/4
495 191/2
338 135/16
338 135/16
515 / 234
Valve Size
TL
TH
h
TW
TR
Weight kg/lbs*
50 (2) TH
mm
inch
215
87/16
75/16
185
51/2
140
129
5
2 3/8
62
7 / 15
40 (11/2) TH
mm
inch
215
87/16
185
75/16
140
5 1/ 2
129
5
62
2 3/ 8
7 / 15
100
(4)
150
(6)
200
(8)
1400
1900
4300
6200
40
40
100
160
350
620
180
180
440
700
1600
2800
2500
3100
3600
5600
7600
8135
43
50
15.4
103
120
6.7
167
195
5.6
407
475
4.8
676
790
5.5
1160
1360
4.5
140
164
3.3
190
222
4.3
460
537
4.3
770
900
4.2
1310
1533
3.6
1600
1900
5
1600
1900
9
3000
3500
3.8
3150
3700
6
3300
3860
5.9
7000
8200
4.2
TR
AL
THAW
TR
AR
AR
TR
AL
50 (2)
80 (3)
100 (4)
150 (6)
200 (8)
AW inch mm inch
mm inch W mm inch mm inch mm
AL
208 83/16 250 913/16 295 111/16 405
16
505 197/8
7
5
1
7
AH
240 9 /16 415 16 /16 445 17 /2 570 22 /16 635
25
AW
170 611/16 200 77/8 235 91/4 330
13
415 AB
165/16
AR
107 43/16 138 57/16 147 513/16 180 71/16 302 117/8
AB
125 415/16 150 57/8 173 613/16 240 97/16 300 1113/16
Weight kg/lbs*
12 / 26
20 / 44
37 / 81
76 / 167
150 / 330
* Approximate shipping Weight (PN 25) ** h = Minimal required maintenance space
AW
AR
84 / 22.2
Valve Size
Valve Size
AR
800 (32)
h
L mm
inch
1850 727/8
AW
TH
1675 6515/16
860 337/8 AW
1090 4215/16
3
TR
603 23AR
/4
2600 / 5730
AL
TH
TH
AH
WAH
84 / 22.2
50 / 13.2
600 (24)
700 (28)
mm
inch
mm
inch
W
1450 571/16 1650
6415/16
1574 6115/16 1675 6515/16
740 291/8WAH860 337/8
1100 435/16 1100 435/16
490 195/16 498 195/8
1950 / 4299
2070 / 4560
L
400 (16)
mm
inch
1100 435/16
W
855 335/8
AH
590 231/4
W
850 337/16
290 117/16 AH
822 / 1812
18.6 / 4.9
84 / 22.2
R
h
7000
8200
7.8
7000
8200
13.4
For head Loss of fully open valves use the following equations:
2
3
2
2
H (Bar) = (Q [m /h])
H (Psi) = (Q [gpm])
H=K V
Kv
Cv
2g
12
Edition 06/2012
Engineering Data
Headloss Charts
M OD
ELS 30 \ 31Pattern)
(GLOBE PATPressure
TERN) PRESSU
RE LOSChart
S CHART
Models 30/31
(Globe
Loss
psi
mwc
10
0mm
24
600 ", 28",
mm
3
, 70 2"
0mm
, 80
0m
8"
200
mm
6"
150
mm
10"
250
mm
1
300 2", 14"
mm
, 35
0mm
400 16" ,1
8
mm
, 45 ", 20"
0mm
, 50
4"
100
mm
3"
80m
1
40m ", 2"
m, 5 , 2 "
0mm
, 65
mm
10
9
8
7
2
1
10
10,000 m3/hr
1,000
100
1,000
100
10,000
3w
gpm
2w
MODELS 3(Angle
0A \ 31A (AN
GLE PATTERPressure
N) PRESSURELoss
LOSS CChart
HART
Models 30A/31A
Pattern)
psi
mwc
10
4
3
10"
250
mm
8"
200
mm
6"
150
mm
4"
100
m
6
3"
80m
m
1
40m ", 2"
m, 5
0 mm
10
9
8
7
2
1
10
10,000 m3/hr
1,000
100
100
1,000
3w
10,000
gpm
2w
13
Edition 06/2012
Engineering Data
AH
R
80 (3)
mm
inch
310 123/16
7 1/4
185
4 1/4
107
7 7/8
200
100 315/16
15 / 33
100 (4)
mm
inch
350 133/4
93/16
232
156
6 1/8
235
9 1/4
120 411/16
27 / 60
150 (6)
mm
inch
480 187/8
10
250
6 3 /4
170
300
113/4
150
5 7 /8
51 / 112
200 (8)
mm
inch
600 235/8
334 131/8
220 811/16
360 143/16
182
63/16
92 / 202
250 (10)
mm
inch
730 283/4
395 151/2
275 1013/16
425 163/4
215
87/16
171 / 377
0.1 / 0.02
0.3 / 0.08
0.7 / 0.2
1.5 / 0.37
4.3 / 1.1
300 (12)
mm
inch
850 337/16
545 211/2
400 153/4
489 191/4
9 3/8
245
330 / 726
350 (14)
mm
inch
980 389/16
635
25
480 187/8
610
24
260 103/16
510 / 1124
400 (16)
mm
inch
1100 435/16
635
25
480 187/8
628 243/4
314 123/8
544 / 1197
450 (18)
mm
inch
1200 471/4
855 335/8
600 235/8
850 337/16
310 123/16
945 / 2083
500 (20)
mm
inch
1250 493/16
855 335/8
600 235/8
850 337/16
357.5 141/16
980 / 2160
600 (24)
mm
inch
1259 499/16
1311 515/8
245
9 5 /8
881 3411/16
459 181/16
1030 / 2266
9.7 / 2.6
18.6 / 4.9
18.6 / 4.9
50 / 13.2
50 / 13.2
50 / 13.2
AW
H
AH
R
AW
80 (3)
100 (4)
150 (6)
200 (8) 250 (10) 300 (12) 350 (14) 400 (16) 450 (18) 500 (20) 600 (24)
60
145
225
510
970
1400
1900
2030
3100
3600
3600
265
640
990
2250
3990
6200
8400
8940
13660
15860
15860
Kv
43
115
165
345
663
1160
1600
1600
3000
3000
3000
Cv
50
133
192
400
770
1360
1900
1900
3500
3500
3500
14
Edition 06/2012
Engineering Data
MODEL
32 (GLOBE PPressure
ATTERN) PRES
SURE LChart
OSS CHART
Model 32 (Globe
Pattern)
Loss
psi
mwc
10
18"
, 20
", 24
mm
"
, 50
0 mm
, 60
0m m
450
14"
,16"
mm
, 40
0 mm
350
m
12"
300
m
10"
250
mm
m
8"
200
m
4
6"
150
m
4"
100
m
3"
80m
m
10
9
8
7
2
1
10
10,000 m3/hr
1,000
100
100
1,000
3w
10,000
gpm
2w
15
Edition 06/2012
Engineering Data
Components
Position Ind. Kit
Lifting Ring
Bonnet Assembly
Spring
Double-Chamber
Conversion Kit
Diaphragm
Assembly
Body Assembly
F Version
Conversion Kit
16
Edition 06/2012
EC
EL
PRM
PR(D)
PR
PS
FR
17
Edition 06/2012
FL
FLEL
FLDI
AL
18
Edition 06/2012
CV Check valve
The valve is in open position when inlet pressure is higher than outlet
pressure.
The valve closes, preventing returning flow, on inverted flow direction.
NS
DW
BC/PS
BC/CD
BC/DI
BC
QR
SP Surge-preventing closure
A unique DOROT control module, that can be added to any automatic
valve. It prevents water hammer, that is generated by the valve closure,
when it is located at the end of a long pipeline.
RE
19
Edition 06/2012
The Dorot UL Deluge Valves are suitable for systems that include Electric,
Hydraulic or Pneumatic detections. The Dorot 300 series Deluge Valves are
activated by each signal or by combinations thereof. All applications are
equipped with a manual emergency actuation valve and approved for use in
Fire Protection Systems as Automatic Reset or Manual Reset Valves.
DE/EL
Deluge Valves
The Dorot 300 Series Monitor Valves are designed to open immediately
as a response to Electric, Hydraulic, Pneumatic or manual activation. The
valves use the line pressure to develop maximum power and do not need
any external source of power.
The Dorot 300 Series Monitor Valves are designed to be activated locally or
remotely.
U-DE/EL
Monitor Valves
The Dorot 300 Series UL Pressure Reducing Valves are hydraulically selfoperating Diaphragm Valves that reduce High upstream pressure to Lower
downstream pressure regardless of the upstream pressure fluctuation or
unstable flow demand.
The Dorot 300 Series UL Pressure Reducing Valves are designed to maintain
constant downstream pressure at all flow conditions.
PR/UL
PS/UL
The Dorot 300 Series UL Pressure Relief Valves are designed to maintain
constant pressure in the fire Protection System and prevent over pressure by
relieving excess pressure back to the reservoir or vent to the atmosphere.
20
Edition 06/2012
Series 100
Series 100
100
100
Mini Pilot-Valves
29-200
29-300
Pilot-Valves
68-410
68-500
CXPS
CXPR
76-610
70-110
Float Pilot-Valves
70-400
Dorot
Dorot
Dorot
70-550
E V E R Y T H I N G
E V E R Y T H I N G
Series
100and Accessories
Pilots
32
Edition 06/2012
70-200
70-300
70-610
70-610
E V E R Y T H I N G
I S
U N D E R
C O N T R O L
U N D E ER V C
E R
O YN TT HR ION L G
I S
U N D E R
C O
32I S
CONTROL VALVES
Dorot
CONTROL VALVES
I S
U N D E R
C O N T R O L
21
Galit
Galit
3-way
3-way // 22 positions
positions NC
NC or
or NO,
NO, small
small hydraulic
hydraulic relay
relay
Series 300
Valves
Metal
Metal Relays
Relays
GALIT
GALIT
25-300
25-300
66-210
66-210
GALIT
66-310
66-310
25-300
28-200
28-200
66-210
66-210
66-310
66-310
D2
D2
28-200
28-200
D3
D3
D2
D3
B2
B2
B2
B3
B3
B3
B2
B3
Y
Y Filter
Filter
FlushingFilter
Filter
Self Flushing
Self
Flushing
Filter
Plastic
Relays40mm to 600mm - 111/2" to 24"
For
For valve
valve sizes
sizes 40mm to 600mm - 31 /2" to 24"
For
valve
sizes 20mm
150mm
Pressure rating:
rating:
25 bar
barto// 360
360
psi - /4" to 6"
Pressure
25
psi
Pressure rating:
10/ 2bar
/ 145 psiNO (66-213: NC) hydraulic relay
66-210
3-way
positions
66-210 3-way / 2 positions NO (66-213: NC) hydraulic relay
25-300 3-way adjustable
/ 2 positions NO w. 3/8"
ports hydraulic relay
66-300
66-300 3-way
3-way adjustable hydraulic
hydraulic relay
relay
Galit 2-way
3-way // 22 positions
positions hydraulic
NC or NO,relay
small hydraulic relay
28-200
28-200 2-way / 2 positions hydraulic relay
Mini
Mini Solenoids
Solenoids
Relay-Valves
For irrigation valve sizes 20mm to 150mm - 33/4" to 6"
For
irrigation
sizes 20mm to 1150mm - /4" to 6"
Metal
Relaysvalve
For valve sizes
40mm
to bar
600mm
Pressure
rating:
10
// 145
psi
Pressure
rating:
10
bar
145
psi- 1 /12 to 24
For
valve
sizes
40mm
to
600mm
Pressure rating:
25Voltage:
bar / 360
psi - 1 /2" to 24"
Operating
Operating
Voltage:
Pressure
rating: 25 barNO
/ 360
psi
66-210 3-way
/ 2 positions
(66-213:
NC) hydraulic relay
AC:
AC: 24V
24V
66-210
3-way
/
2
positions
NOrelay
(66-213: NC) hydraulic relay
66-310 3-way
adjustable
hydraulic
DC:
12V
or
24V
DC: 12V or3-way
24V adjustable hydraulic relay
66-300
28-200 2-way
/6-40V
2 positions
hydraulic relay
Latch
Latch 6-40V
28-200
2-way / 2 positions hydraulic relay
28-300 3-way
NO/NC
hydraulic relay
D2 / 2 positions
2-way NC
NC solenoid
solenoid
valve
D2
2-way
valve
D3
3-way
D3
3-way NC
NC or
or NO
NO solenoid
solenoid valve
valve
28-300
Mini Solenoids
Heavy-duty
Solenoid Valves
For irrigation valve sizes 20mm to 150mm - 3/4" to 6"
Heavy-duty
Solenoids
Heavy-duty
Solenoids
For valve sizes
20mm
to bar
600mm
Pressure
rating:
10
/ 145 psi- 3/34 to 24
For
valve
sizes
20mm
600mm -- 3/4
/4"" to
to 24"
24"
For
valve
sizes
20mm to
to
Pressure rating:
According
to600mm
the selected
orifice and
Operating
Voltage:
Pressure
rating:
According
to
the
selected
orifice
Pressure
rating:
According
to
the
selected
orifice and
and solenoid
solenoid type
type
solenoid type
AC: 24V
Operating
Voltage
(others
available
upon
request):
Operating
Voltage
(others
available
upon
request):
Operating Voltage
available upon request):
DC: 12V or(others
24V
AC:
110V
or
AC: 24V,
24V,
110V
or 220V
220V
AC: 24V, 110V
or
220V
Latch
6-40V
DC:
12V
24V
DC:
12V or
or2-way
24V NC solenoid valve
DC: 12V orD2
24V
Latch
9V,
12V,
24V
Latch
9V,
12V,
24VNC or NO solenoid valve
Latch 9V, 12V,
D3 24V3-way
B2
2-way
NC
solenoid
B2 or NO
2-way
NC or
or NO
NOvalve
solenoid valve
valve
B2 2-way NC
solenoid
B3
3-way
NC
or
NO
solenoid
B3 or NO
3-way
NC or NOvalve
solenoid valve
valve
B3 3-way NC
solenoid
Heavy-duty Solenoids
For valve sizes 20mm to 600mm - 3/4" to 24"
Pressure
rating: According to the selected orifice and solenoid type
Control
Control Filters
Filters
Operating
Voltage
(others
available
upon request):
Self-Flushing,
Inline
Stainless
steel screen
screen
filter,filter,
locatedlocated
within the
the
Self-Flushing,
InlineInline
Stainless
steel
screen
Self-Flushing,
Stainless
steel
filter,
located
within
AC:
24V,
110V
orrinsed
220Vcontinuously by the stream
main
valve,
and
within the main
valve,
continuously
main valve,
andand
rinsedrinsed
continuously
by the streamby the stream
DC: 12V
or 24V
1 "
Sizes: 1/4, 1Sizes:
/2, 111/4
/4",
/2"
", 1/2
Sizes:
Latch
9V,
12V,type
24V- Stainless steel screen installed in a "Y"
External,
"Y"
External, Y
type
Stainless
screen
installed
External, "Y"- type
- Stainlesssteel
steel screen
installed
in a "Y"in a Y
B2
2-way
NCpressure
or NO solenoid
shaped
body
on the
the
source. valve
shaped body
on body
the pressure
source.
shaped
on
pressure
source.
B3 33/8",3-way
NC or NO solenoid valve
Sizes: 3/8, 1Sizes:
/2 /8", 11/2
/2""
Sizes:
External,
-- A
volume
external
External, large
- Alarge
large
volume
filter
External,
large
A large
large
volumeexternal
external filter
filter
Control Filters
Control Filters
Self-Flushing, Inline Stainless steel screen filter, located within the
main valve, and rinsed continuously by the stream
Sizes: 1/4", 1/2"
External, "Y" type - Stainless steel screen installed in a "Y"
shaped body
on the pressure
E source.
V E
E R
R Y
Y T
T H
H II N
N
CONTROL VALVES
E
V
CONTROL VALVES
Sizes: 3/8", 1/2"
External, large - A large volume external filter
Dorot
Dorot
CONTROL VALVES
G
G
E V E R Y T H I N G
II S
S
U
U N
N D
D E
E R
R
Y Filter
I S
U N D E R
C
C O
O N
N T
T R
R O
O L
L
Self Flushing Filter
C O N T R O L
22
Edition 06/2012
Mechanical Valves
Water Meters
Water Meters Multi-Jet, Single-Jet,
Irrigation Meters, Woltman
Meters, Volumetric Meters.
23
Edition 06/2012
Setting New
Global Standards
of Innovation, Expertise
and Reliability
agricultural
sectors
around
the
world
have
water-management
solutions,
the
company
www.dorot.com