Sie sind auf Seite 1von 4

Touch-Type Graphic Recorder

Features
High-definition screen
5.7 640480 TFT-LCD

Multi input type

2 kinds of RTD, 12 kinds of thermocouple, 4 kinds of DC voltage

Trend view function

Users can input special event messages on the graphs

Supply big capacity memory

SD and SDHC memory card available

422/485 communication function (Modbus, PC Link)


Supply communication program for free

3 different languages
Korean, English, Chinese

Ability to save data and back up parameter through SD Card


Remote monitoring by smart phone

Remote monitoring by smart phone


W
 hen

connecting to ethernet convertor, HMCE-103,


remote monitoring service with Smartphone Apps is
available

When

alarm rings at GR200, you can know it in real time


through Smartphones alarm facility (In-Study)

Ethernet Convertor
HMCE-103

Various
display screens
Trend view

Ap

pl
ica
tio
n

Text view

Temperature & humidity chamber

Food sterilizer

Bar graph view

GR AP HI C R ECOR DER
Menu screen icon

USING THE TOUCH PANEL

Selection of trend view, text view, bar graph view

Set up arithmetic function for input parameter


Channel configuration

Operating screen

Check the save log

Checking the saved graph or copying the internal


memory of data to SD Card

Set up alarm or contact input (D.I) parameter


Warning and DI

Display & save the event record and display the


output status in real time

Set up the operation parameter

History management

Function configuration

Date / reservation
configuration

NEW

Set up a present time or start / close


time for reservation

Set up language in use, password and


communication etc

System configuration

History report

Graphic viewer

Save event or error history.


Present output status can be checked in the screen

User can check data in the internal memory or SD card.


Saved data can be zoom in or zoom out based on time axis or size axis
Time axis (X16 oom in)

Size axis (X8 zoom out)

Trend view function

Arithmetic function

Display special event messages on the graphs

Various arithmetic functions

Consumer Logo
Possible to change the display of logo what consumers want

LO
LO
GO
LO
LO
GO
GO

LO
LO

GOLO
LO
GO
GO
GO

GO
Change the
Consumer Logo

Touch Type Graphic Recorder


Suffix code

Input
channel

2 channels

4 channels

8 channels

12
Input / Output
(DI / DO)

Dimension (Unit : )

GR200 Graphic recorder

Panel cutout
173.5
164.7
148.7

8.8

145.0

170.0

12 channels
N

None

D.I 2 + Relay 6

Communication

(Unit : )

138.0 +0.5
-0

Dimension & panel cutout

Description

170.0

GR200 -

Code

145.0

Model

138.0 +0.5
-0

D.I 4 + Relay 12
0

RS 422/485

ETHERNET (On development )

Specification
Power supply voltage

100 - 240 V AC (voltage fiuctuation : 10 %)

Power frequency

50 - 60

General
Power consumption
specificatioin

max 22 VA

Dimension ()

External memory

SD card (2GB) : In case of 1 second of record cycle, it saves


data for 1 year. (Support SDHC)

File type

FAT 16/32 (SD card)


1, 2, 5, 10, 20, 30, 60, 120 sec
Display important event messages in the trend view

Weight

Approx. 1.3

Channel

2 Channels, 4 channels, 8 Channels, 12 Channels

LIST

RTD 2 type (Pt-100, KPt-100),


Thermocouple 12 type (K, J, E, T, R, B, S, L, N, U, Wre 5-26, PL-)
DC voltage 4 type (-10 - 20 , 0 - 100 , 1 - 5V, 0 - 30 V)

Indicator

Display

TFT color LCD (115.2 86.4 , 640 480 pixel)


LED Backlight

Language

Korean, English, Chinese

Approx 0.21

Screen setting

Trend view, Text view

Accuracy

0.15 % of F.S, 1 digit (Except RJC temperature error)

Save history view

Check saved data and Provide zoom in & zoom out function

RJC temperature error

2.0 (0 ~ 50 )

External direct input (DI)

2 contacts, 4 contacts

Input type

Non-voltage contact input

Contact output

6 contacts, 12 contacts (N.O)

Contact capacity

3 A 250 V AC (3 A 30 V DC)

Sampling time

250

RTD measuring current

Alarm setting
Alarm type

D.I.

Display UP-Scale

(Option)

2 settings within each channel

Output

Burn-out

Alarm

Non-volatile flash memory (80 MB)


: In case of 1 second of record cycle, It saves data for 15 days

Record cycle

Input type

Input

144 (W) 144 (H) 173.5 (D)

Save
function

Internal memory

High/Low, Alarm within high/low range, Alarm without high/low range etc.. (Option)

Terminal wiring diagram

Communication

DI

Input

Ethernet

Power

Output Relay

HANYOUNG NUX CO.,LTD


28, Gilpa-ro 71 beon-gil, Nam-gu, Incheon, Korea
Tel : +82-32-876-4697
Fax : +82-32-876-4696

E-mail : overseas@hynux.com

Information in this catalog may change without prior notice for upgrade purpose.