Commercial
outdoor
packaged
systems
*In DX refrigeration the air is cooled directly exchanging heat from the refrigerant.
The principal advantages of central air conditioning systems are
better control of comfort conditions, higher energy efficiency and greater loadmanagement potential. The main drawback is that these systems are more expensive to
install and are usually more sophisticated to operate and maintain.
The principle advantages of decentralized air conditioning
systems is lower initial costs, simplified installation, no ductwork or pipes, independent
zone control, and less floor space requirements for mechanical room, ducts and pipes.
A great benefit of decentralized systems is that they can be individually metered at the
unit. Disadvantages are short equipment life (10 years), higher noise, higher energy
consumption (kW/ton) and are not fit where precise environmental conditions need to be
maintained.
2.DUCT DESIGNING
The chief requirements of an air conditioning duct system are:
1. It should convey specified rates of air flow to prescribed locations
2. It should be economical in combined initial cost, fan operating cost and cost of
building space
3. It should not transmit or generate objectionable noise
Generally at the time of designing an air conditioning duct system, the
required airflow rates are known from load calculations. The location of fans and air
outlets are fixed initially. The duct layout is then made taking into account the space
available and ease of construction. In principle, required amount of air can be conveyed
through the air conditioning ducts by a number of combinations. However, for a given
system, only one set results in the optimum design. Hence, it is essential to identify the
relevant design parameters and then optimize the design.
Heating coil, which raises the air temperature to the required supply
temperature.
Cooling coil, which provides cooling and dehumidification. A thermostat
mounted in the space will normally control this coil. Asingle thermostat
and controller are often used to control both the heating and cooling coil.
This method reduces energy waste, because it ensures the two coils
cannot both be on at the same time.
Humidifier, which adds moisture, and which is usually controlled by a
humidistat in the space. In addition, a high humidity override humidistat
will often be mounted just downstream of the fan, to switch the
humidification off if it is too humid in the duct. This minimizes the
possibility of condensation forming in the duct.
Fan, to draw the air through the resistance of the system and blow it into the
space.
These components are controlled to achieve six of the seven air-conditioning
Heating: directly by the space thermostat controlling the amount of heat
supplied by the heating coil.
Cooling: directly by the space thermostat controlling the amount of cooling
supplied to the cooling coil.
processes.