Models Available
DH100ACDCI 4-wire Ionization Detector
DH100ACDCP 4-wire Photoelectronic Detector
Features
Specifications
Length:
Width:
Depth:
Shipping Weight:
Operating Temperature Range:
Photoelectric:
Ionization:
Operating
Humidity Range:
Air Duct Velocity:
32 to 131 F (0 to 55 C)
32 to 120 F (0 to 49 C)
APPROVED
* Patent pending
System Sensor 7/99
A05-977-02
Architectural/Engineering Specifications
The air duct smoke detector shall be a System Sensor
Model DH100ACDC Series Duct Smoke Detector. The
detector housing shall be UL listed per UL 268A
specifically for use in air handling systems. The detector
shall operate at air velocities of 500 feet per minute to
4000 feet per minute. The unit shall be capable of
controlling up to ten (10) air handling systems when
interconnected with other detectors. The detector shall
be capable of providing a trouble signal in the event that
the front cover is removed. It shall be capable of local
testing via magnetic switch or remote testing using the
SSK451 Multi-Signaling Accessory or the RTS451KEY
Remote Test Station. The unit shall be reset by local reset
button or remote test station. The duct smoke detector
housing shall incorporate an airtight smoke chamber in
Wiring Guide
System wiring diagram for 4-wire duct smoke detectors
AVAILABLE POWER INPUTS
120
VAC
24V
120
VAC
24V
220/240
VAC
220/240
VAC
16
N.C.
C.
N.O.
N.O.
10
10
C.
N.C.
N.C.
C.
17
N.O.
N.O.
18
C.
N.C.
14
14
+
4
4
ALARM
INITIATION
LOOP
CONTACTS SHOWN
OPEN IN STANDBY.
CONTACTS CLOSE
IN ALARM.
ALARM
INITIATION
CONTACTS
5
CONTACTS SHOWN
OPEN IN STANDBY.
CONTACTS CLOSE
IN ALARM.
ALARM
INITIATION
CONTACTS
5
UL LISTED 4-WIRE
CONTROL PANEL
Page 2
EOL RESISTOR
SPECIFIED BY
PANEL MANUFACTURER
A05-977-02
20-29 VDC
270 F max.
3.0 VDC min.
.03 to 0.3 sec.
0.6 sec. max.
34 sec. max.
2 to 17 sec.
See detector label
24 VAC 50-60-Hz
270 F max.
2.0 VAC min.
.03 to 0.3 sec.
0.6 sec. max.
34 sec. max.
2 to 17 sec.
See detector label
20 - 29 VDC
24 VAC 50 - 60 Hz
120 VAC 50 - 60 Hz
220/240 VAC 50 - 60 Hz
15 mA
35 mA RMS
25 mA RMS*
15 mA RMS*
70 mA
125 mA RMS
35 mA RMS*
25 mA RMS*
CONTACT RATINGS
Alarm initiation contacts (SPST)
10A @ 30 VDC
10A @ 250 VAC
Note: Alarm auxiliary contacts must switch 100mA minimum at 5VDC. Alarm auxiliary contacts shall not be
connected to inititaing circuits of control panels. Use the alarm initiation contact for this purpose.
Aux. Power +
19
14
Sup. COM
Alarm
Power
20
Common
NOTE:
NOTE:
TEMPORAL SELECT
ALARM
n/a
30mA Max.
PA400
0mA
n/a
15mA Max.
RA400Z
0mA
n/a
10mA Max.
RTS451/RTS451KEY
12mA*
n/a
7.5mA Max.
SSK451
5mA Max.
9mA Max.
30mA Max.
15
ALARM SIGNAL
ALARM SIGNAL
14
RESET
TEST
11
TEST
POWER (-)
20
POWER (+)
19
12
INTERCONNECT +
INTERCONNECT -
SUPERVISORY
CONTACT
NO
RESET
UNIT 1
SSK451
FIELD INSTALLED
JUMPER
SUPERVISORY SIGNAL
12
INTERCONNECT +
INTERCONNECT DH100ACDC
UNIT 2
Coil Note
Please note that the magnetic coil supplied with the
RTS451 and RTS451KEY is not required when these
accessories are used with the DH100ACDC detectors.
The functionality of the magnetic coil has been
designed into the circuitry of the new Innovair duct
smoke detectors.
Page 3
TROUBLE
12.5mA Max.
Aux. Power
STANDBY
APA451
APA451
Alarm Signal
Sup. N. O.
DEVICE
RTS451/RTS451KEY
Alarm Signal
15
Aux. Power +
19
Sup. N. O.
14
Sup. COM
Aux. Power
Reset
Test
20
11
Interconnect 1
5
Interconnect +
Unit 1
12
DH100ACDC
UNIT 2
Interconnect 1
Interconnect +
12
A05-977-02
Ordering Information
Part No.
DH100ACDCI
DH100ACDCP
A5052
A5069
A5064
Accessories
ST-1.5
ST-3
ST-5
ST-10
T80-71-00
P48-55-00
SSK451
RTS451KEY
RTS451
APA451
MOD400R
RA400Z
F36-09-00
M02-04-00
P48-21-00
S08-39-01
PA400W
PS24LO
PS12/24LENSC
PS12/24LENSW
Description
4-wire ionization duct detector
4-wire photoelectronic duct detector
Replacement ionization detector board
Replacement photoelectronic detector board
Replacement 4-wire power board
Metal sampling tube duct widths 12
Metal sampling tube duct widths 24
Metal sampling tube duct widths 48
Metal sampling tube duct widths 812
Replacement telescoping sampling tube
Replacement end cap for T80-71-00
Multi-Signaling accessory
Remote test station with key lock (see below)
Remote test station
Remote annunciator with piezo alarm
Sensitivity test module
Remote annunciator alarm LED (see below)
Replacement air filters (two per package)
Test magnet
End cap for metal sampling tubes
Photo replacement screen
Mini-Alert sounder
Mini-Alert add-on strobe
Ceiling-mount SMOKE lens
Wall-mount SMOKE lens
Accessories
annunciation. As with our duct detectors, all duct detector
accessories are UL listed.
F
I
R
E
ALARM
ALARM
POWER
RESET
APA451
Piezo
Annunciator
(UL S4011)
ON
TEST
RTS451KEY
Remote Test
Station with Key
(UL S2522)
ALARM
RESET
PA400 with
PS24LOW Add-on Strobe
(PS12/24SLENSW
smoke lens option available)
(UL S3593)
RTS451
Remote Test
Station
(UL S2522)
RA400Z
Remote
Annunciator
(UL S2522)
S
M
O
K
E
SSK451
SSK451 with
PS24LOW Strobe and
PS12/24SLENSW
SMOKE Lens
System SensorAustralia
Ph: 011.613.54.281.142
Fx: 011.613.54.281.172
A05-977-02