Beruflich Dokumente
Kultur Dokumente
Installation Guide
Issue: 05
Part Number: 31504449
Date: 2009-03-05
HUAWEI TECHNOLOGIES CO., LTD.
Content
Safety Information
15
17
19
23
28
33
39
41
42
12. Reference
43
Safety Information
Following All Safety Precautions
Before any operation, read the instructions and precautions in this document carefully to minimize the possibility
of accidents.
The Danger, Caution, and Note items in the documents do not cover all the safety precautions that must be
followed. They only provide the generic safety precautions for operations.
When operating Huawei products and equipment, you must comply with safety precautions and special safety
instructions related to corresponding equipment provided by Huawei. The safety precautions in the document
are related to only Huawei products. Huawei is not liable for any consequence that results from the violation of
universal regulations for safety operations and safety codes on design, production, and equipment use.
Symbols
This symbol indicates that casualty or serious accident may occur if you ignore
the safety instruction.
This symbol indicates that serious or major injury may occur if you ignore the
safety instruction.
This symbol indicates that the operation may be easier if you pay attention to the
safety instruction.
Safety of Personnel
The high voltage power supply provides power for running the system. Direct contact with the high voltage
power supply or contact through damp objects may result in fatal danger.
Non-standard and improper high voltage operations may result in fire and electric shock.
In a thunderstorm, do not perform operations on high voltage and AC power supply facilities or on a steel
tower and mast.
Ground the device before powering on the device. Otherwise, the personnel and device are in danger.
Power off the device before performing operations on the power supply equipment.
High power radio-frequency signals are harmful to human body. Before installing or maintaining an antenna
on a steel tower or mast with a large number of transmitter antennas, the operator should coordinate with all
parties to ensure that the transmitter antennas are shut down.
When handling optical fibers, do not stand close to, or look into the optical fiber outlet with unaided eyes.
Protect yourself when drilling holes. Flying dust may hurt your eyes or you may inhale the dust.
Power off the batteries before connecting the cables to the batteries. Otherwise, casualties may occur.
When working at a height, be cautious about falling objects.
Device Safety
Check the electrical connection of the device before operation and ensure that the device is reliably grounded.
The static electricity generated by the human body may damage the electrostatic sensitive components on
the circuit board, such as the large-scale integrated circuit (LIC). Wear an ESD wrist strap or ESD gloves when
performing the operation.
When working on batteries, take measures to prevent short circuits in the batteries and electrolyte spill/loss.
The electrolyte may erode metal and boards, or even cause rust of the equipment or short circuits in the boards.
The NodeB must be powered on within one week after installation.
Installation Tools
Insulated screwdriver
Adjustable wrench
Cross screwdriver
Socket wrench
Straight screwdriver
Torque wrench
Wire cutter
Rubber hammer
Claw hammer
Cable peeler
Percussion drill
Multimeter
Heat gun
Level bar
Vacuum cleaner
Installation Scenarios
1.APM30
2.APM30H
BBU
BBU
3.TMC
4.TMC11H
BBU
BBU
Installation Scenarios
6.PS4890
5.APM30 (+24V
BBU
BBU
7. In OMB cabinet
9. On the Wall
BBU
BBU
BBU
Board
Mandatory/Op
tional
Full
Configuration
Installation Slot
Remarks
WMPT
Mandatory
S6 and S7
WBBP
Mandatory
S0 to S3
UPEU
Mandatory
UBFA
Mandatory
FAN
UTRP
Optional
S0 to S5
UELP
Optional
S0 and S4
UFLP
Optional
S0 and S4
UEIU
Optional
PWR1
Monitoring
Equipment
Power System
Alarm Cable
CPRI Optical
E1 Cable
FE cable
Monitoring Cable
Procedure
Cable connections
NO.
Cable
Installation Position
From...
To ...
LOAD3 on PDU
PWR on BBU
E1 transfer cable
E1/T1 on WMPT
INSIDE on UELP
E1cable
OUTSIDE on UELP
Transmission equipment
Monitoring cable
TX/RX on APMI
MON1on BBU
CPRI
CPRI on BBU
CPRI on RRU
Installing BBU
1 Install the mounting ears at both sides of
the BBU reversely.
PDU
BBU
M6 bolt
Installing cables
1. Install power cable.
Connect the OT terminal of the power cable to the LOAD3
terminal of the PDU, and then fix the 3V3 connector of the
power cable to the PWR port on the BBU.
LOAD3
NEG(-)
RNT(+)
PWR
The power cable is to be made
depending on field requirements.
Optical module
Puller
Wrap the fiber tail with the winding pipe till the
first cable tie.
Optical cable
connector
Winding pipe
10
E1 cable
25mm
E1 transfer cable
INSIDE
OUTSIDE
Shielding layer
of the E1 cable
E1/T1
11
FE transfer cable
FE cable
INSIDE FE0
OUTSIDE FE0
FE0
12
MON1
EXT-ALM1
External alarm
cable
MON0
RS485
13
Color
Type
X1.1
X2.3
White
Twisted pair
TX+
X1.2
X2.7
Orange
X1.4
X2.2
Blue
X1.5
X2.6
White
14
TXTwisted pair
RX+
RX-
No.
Cable
Installation Position
One end is connected to...
E1 transfer cable
E1 cable
Monitoring signal
cable
CPRI optical
cable
15
Installing the Monitoring Signal Cable between the HEUA and the BBU
HEUA
COM IN
MON1
UPEU on the
BBU
16
No.
Cable
Installation Position
One end is connected to...
E1 surge protection
transfer cable
E1 cable
Monitoring signal
cable
17
Wire Color
Wire Type
X1.1
X2.1
White/orange
Twisted pair
X1.2
X2.2
Orange
X1.3
X2.3
White/green
X1.6
X2.6
Green
X1.5
X2.5
White/blue
X1.4
X2.4
Blue
X1.7
X2.7
White/brown
X1.8
X2.8
Brown
18
Twisted pair
Twisted pair
Twisted pair
No.
Cable
Installation Position
From...
To...
BBU power
cable
E1 cable
FE cable
(optional)
Monitoring
signal cable
CPRI optical
cable
19
Space Requirements
Slide the BBU case into the cabinet. Then, tighten the four M6 screws.
20
Grounding bolt
on the right side
of the BBU
PGND cable
PWR
EXT-ALM0
21
MON1
E1/T1
E1/T1
Insert the optical module into the CPRI0, CPRI1, or CPRI2 port.
Turn outwards the puller on the optical module.
Optical module
Puller
Winding pipe
22
External
grounding bar
External power
equipment
External
External transmission
equipment
grounding bar
External monitoring
equipment
SN
Cable
Installation Position
One End Connected to...
E1 cable
External transmission
equipment
Monitoring signal
cable
PGND cable
23
Space Requirements
A single BBU
BBUDCDU-03C
DCDU-03C
BBU
Mounting ear
for wall installation
24
2. Place the BBU against the wall, and then use the marking pen to mark
the holes of the mounting ears for wall installation.
wall
BBU
Bolt M1080
Nut
Spring washer 10
Flat washer 10
Expansion tube
55mm60mm
20mm
25
Flat washer
Spring washer
wall
26
Bolt M1080
Nut
Spring washer 10
Flat washer 10
Expansion tube
55mm60mm
20mm
27
No.
Cable
Installation Position
From...
To...
E1 cable
External transmission
device
External transmission
device
28
Slide the BBU case into the PS4890 cabinet. Then, tighten the four M6 screws.
29
LOAD 6
PWR
30
MON0
RS232/RS422
EXT ALM1
31
Optical
module
Puller
E1/T1
Winding pipe
32
No.
Cable
Installation Position
From...
To...
PGND cable
of the OMB
3
E1 transfer cable
E1 cable
33
Inner hexagon
spanner
255~306kgfcm
Inner hexagon
spanner
255~306kgfcm
Flat Spring
washer washer
Bolt M10110
34
35
NEG(-)
RNT(+)
LOAD6
36
OUTSIDE
E1/T1
INSIDE
Shielding layer
37
Optical module
Puller
38
No.
Cable
Installation Position
From...
To...
E1 transfer cable
E1 cable
39
APMI
Door status sensor
Wiring
terminal
of
DCDU surge protection
40
No.
Cable
Installation Position
From...
To...
E1 transfer cable
E1 cable
Monitoring signal
cable
41
a
No
End
a
The normal status of LED on the
WMPT is as follows:
RUN LED: 1s ON, 1s OFF
(blinking at 0.5 Hz)
ALM LED: OFF
ACT LED: ON
The normal status of LED on the
UBFA is as follows:
STATE LED: Green
1s ON, 1s OFF (blinking at 0.5 Hz)
The normal status of LED on the
UPEU is as follows:
RUN LED: ON
The normal status of LED on the
WBBP is as follows:
RUN LED: 1s ON, 1s OFF
(blinking at 0.5 Hz)
ALM LED: OFF
42
12 Reference
c
a
Cable List
Cable
Connector
Connects to
PGND cable
OT terminal
OT terminal
3V3 connector
DLC connector
DLC connector
Peer device
E1 cable
43
12 Reference
c
a
Cable List
Cable
Connector
Connects to
E1 transfer
RJ45 connector
RJ45 connector
Routing equipment
RJ45 connector
RJ45 connector
Monitoring
RJ45 connector
signal cable
between the
RJ45 connector
cable
FE cable
FE transfer
cable
44
12 Reference
a
Cable List
Cable
Connector
Connects to
APMI-BBU
Monitoring
Be connected
APMI
RJ45 connector
RJ45 connector
RJ45 connector
signal cable
EMUA Monitoring
signal cable
Alarm cable
UPEU
RJ45 connector
45
12 Reference
b
Item
Specification
Dimensions
Weight
Input voltage
48 V DC or +24 V DC
ESD strap
ESD gloves
46
12 Reference
c
75-ohm E1 Mode
Other Modes
75-ohm E1 Mode
47
120-ohm E1 Mode
12 Reference
ed
Wire Type
X1.1
Tip
X1.2
Ring
X1.3
Tip
X1.4
Ring
X1.5
Tip
X1.6
Ring
X1.7
Tip
X1.8
Ring
X1.19
Tip
X1.20
Ring
X1.21
Tip
X1.22
Ring
X1.23
Tip
X1.24
Ring
X1.25
Tip
X1.26
Ring
Connector
48
RX1+
RX1-
RX2+
RX2-
RX3+
RX3-
RX4+
RX4-
TX1+
TX1-
TX2+
TX2-
TX3+
TX3-
TX4+
TX4-
12 Reference
d
120-ohm E1 cable
Pin on the DB26 Male
Wire Color
Wire Type
Label
Connector
X1.1
Blue
RX1+
Twisted pair
X1.2
White
RX1-
X1.3
Orange
RX2+
X1.4
White
X1.5
Green
X1.6
White
X1.7
Brown
Twisted pair
RX2RX3+
Twisted pair
RX3RX4+
Twisted pair
X1.8
White
X1.19
Grey
RX4TX1+
Twisted pair
X1.20
White
X1.21
Blue
TX1TX2+
Twisted pair
X1.22
Red
X1.23
Orange
TX2TX3+
Twisted pair
X1.24
Red
TX3-
X1.25
Green
TX4+
X1.26
Red
Twisted pair
49
TX4-
12 Reference
d
FE cable
Pin on the RJ45
Connector
Wire Color
Wire Type
X1.2
Orange
Twisted pair
X2.2
X1.1
White/orange
X1.6
Green
X1.3
White/green
X1.4
Blue
X1.5
White/blue
X1.8
Brown
X1.7
White/brown
X2.1
Twisted pair
X2.6
X2.3
Twisted pair
X2.4
X2.5
Twisted pair
X2.8
X2.7
Wire
Pins on the
Connector
Color
Wire Type
Port on the
APMI
and X5
X1.1
White
X2
Twisted
TX+
pair
X1.2
Orange
X3
Twisted
pair
TX-
X1.4
Blue
X4
Twisted
RX+
pair
X1.5
White
X5
Twisted
pair
50
RX-
12 Reference
d
Pin on the
Wire
Wire
Port on the
Connector
DB9 Male
Connector
Color
Type
APMI
X1.1
X2.3
White
Twisted
TX+
pair
X1.2
X2.7
Orange
Twisted
TX-
pair
X1.4
X2.2
Blue
Twisted
RX+
pair
X1.5
X2.6
White
Twisted
pair
RX-
Alarm cable
Pin on the RJ45
Wire Color
Wire Type
Connector
Connector
X1.1
X2.1
White/orange
Twisted pair
X1.2
X2.2
Orange
X1.3
X2.3
White/green
X1.6
X2.6
Green
X1.5
X2.5
White/blue
X1.4
X2.4
Blue
X1.7
X2.7
White/brown
X1.8
X2.8
Brown
51
Twisted pair
Twisted pair
Twisted pair