Beruflich Dokumente
Kultur Dokumente
Version 19/07/2012
Construction
Uses
Characteristics /
Advantages
Reducing gaseous expansion system compensates for shrinkage and settlement in the plastic state
No metallic iron content to cause staining
Prepackaged grout overcomes potential on-site batching variations
Develops high early strength without the use of chlorides
High ultimate strength and low permeability ensure the durability of the
hardened grout
Against carbon dioxide and chloride diffusion
Tests
Approval / Standards
Form
Appearance
Powder
Colour
Grey
Packaging
25 kg / bag
Construction
Storage
Storage Conditions
Shelf Life
12 months
Technical Data
Yield
Properties
W/P ratio
Plastic:
Flowable:
0.16 - 0.17
0.18 - 0.19
The following results were obtained at a water : powder ratio of 0.15 and
temperature of 25C. Test method of typical result.
Fresh Wet Density
Youngs Modulus
28 kN/mm
Expansion
0.25% - 1.0%
ASTM 469-83
ASTM C 827-84
15 Minutes
Finish:
2 Hours
System
Information
Foundation Surface
The substrate surface must be free from oil, grease or any loosely adherent
material. If the concrete surface is defective or has laitance, it must be made
to a sound base. Bolt holes and fixing pockets must be blown clean of any
dirt or debris.
Pre-soaking
Application Conditions /
Limitations
Low Temperature
Working
Construction
High Temperature
Working
Application
Instructions
Mixing
Removable hopper:
For larger pours the grout may be hand placed or pumped into a removable
hopper (trough).
Pouring should be from one side of the void to eliminate any air or pre-soaking
water becoming trapped under the base plate. It is advisable to pour the grout
across the shortest distance of travel. The grout head must be maintained at
all time so that a continuous grout front is achieved.
Where large volumes have to be placed SikaGrout -214-11 HF2 may be
pumped. A heavy duty diaphragm pump is recommended for this purpose.
Screw feed and piston pumps may also be suitable.
Curing
Cleaning
Placing
At 20C place the grout within 20 minutes of mixing to gain full benefit of
the expansion process.
SikaGrout -214-11 HF2 can be placed in thickness up to 100 mm in a
single pour when used as an under plate grout. For thicker section it is
necessary to fill out SikaGrout -214-11 HF2 with well graded silt free
aggregate to minimize heat build up, typically a 10mm aggregate is suitable.
Any bolt pockets must be grouted prior to grouting between the substrate
and the base plate.
Continuous grout is essential. Sufficient grout must be prepared before
starting. The time taken to pour a batch must be regulated to the time to
prepare the next one.
Construction
Base Plate
It is essential the surface is clean and free from oil release or scale. Air
pressure relief holes should be provided to allow venting of any isolated
high spots.
Leveling Shims
If these are to be removed after the grout has hardened, they should be
treated with a thin layer of grease.
Formwork
Unrestrained
Surface Area
This must be kept to a minimum gap. Generally the gap width between
the perimeter formwork and the plate edge should not exceed 150 mm on
the pouring side and 50 mm on the opposite side. It is advisable where
practical to have no gap at the flank sides.
Consistency of Grout
Mix
Notes on Application /
Limitations
All grouting works where its intended to use must be carried out with a
prepackaged cement based product which is chloride-free.
It shall be mixed with water to the required consistency. The plastic grout
must not bleed or segregate.
The storage, handling and placement of the grout must be in strict
accordance with the manufacturers instruction.
Performance
@1 day
@3 days
@7 days
Compressive
Strength (Flowable)
40 N/mm2
55 N/mm2
60 N/mm2
Compressive
Strength (Plastic)
45 N/mm2
60 N/mm2
65 N/mm2
Flexural strength
2.5 N/mm2
9.0 N/mm2
@28 days
65 N/mm2
75 N/mm2
10.0 N/mm2
SikaGrout -214-11 HF2 is alkaline and should not come into contact with
skin and eyes. Avoid inhalation of dust during mixing. Gloves, goggles and
dust mask should be worn. If contact with skin occurs, wash with water.
Splashes to eyes should be washed immediately with plenty of clean water
and seek medical advice sought.
Fire
The information, and, in particular, the recommendations relating to the application and end-use of Sika products, are given in good faith
based on Sikas current knowledge and experience of the products when properly stored, handled and applied under normal conditions in
accordance with Sikas ecommendations. In practice, the differences in materials, substrates and actual site conditions are such that no
warranty in respect of merchantability or of fitness for a particular purpose, nor any liability arising out of any legal relationship whatsoever,
can be inferred either from this information, or from any written recommendations, or from any other advice offered. The user of the product
must test the products suitability for the intended application and purpose. Sika reserves the right to change the properties of its products.
The proprietary rights of third parties must be observed. All orders are accepted subject to our current terms of sale and delivery. Users must
always refer to the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.