Beruflich Dokumente
Kultur Dokumente
PC SHEET PILES
DESCRIPTION
Type of Sheet Piles
Method of Installation
Manufacturing
996
440
215
Cgc
110
220 109
338
160 118
109 169
109
162.5
325
162.5
Cgc
120
220
220
117
123 155
138 140
155 123
Cgc
225
246
155
996
440
Cgc
280
120
220
220
Cgc
130
W-450
276
996
440
130
220
150 128
140
300
480
Cgc
600
300
120
220
220
150
W-500
296
500
250
120
140
400
140 138
250
220
200
200
128 150
380
220
130 148
W-400
450
225
120
155
117
175
350
175
W-350
330
220
322
996
440
148 130
118 160
230
W-325
996
440
996
440
256
150
220
W-600
Concrete Compressive Strenght fc = 62 MPa (Cube 700 kg/cm2)
Type
Width
(mm)
Cross Section
(cm2)
Section Inertia
(cm4)
Unit Weight
(kg/m)
W-325
996
1,315
134,264
329
W-350
996
1,468
169,432
368
W-400
996
1,598
248,691
400
W-450
996
1,835
353,363
459
W-500
996
1,818
462,373
455
W-600
996
2,078
765,907
520
Class
Moment Crack
(ton.m)
Length*
(m)
A
B
A
B
A
B
A
B
A
B
A
B
11.40
13.30
15.60
17.00
20.10
23.40
26.90
30.70
35.20
40.40
50.60
59.60
8 - 15
8 - 16
9 - 17
10 - 18
10 - 18
11 - 20
11 - 20
12 - 21
12 - 22
13 - 24
14 - 25
15 - 27
Note : * Length of Concrete Corrugated Sheet Piles may exceed usual standard whenever lifted in certain position
1st Edition - 2012
SHEET PILES
Cgc
220
110
Cgc
320
160
110
500
500
FPC/FRC-220
FPC/FRC-320
160
Type
Width
(mm)
Cross Section
(cm2)
Section Inertia
(cm4)
Unit Weight
(kg/m)
FRC-220
500
1,095
44,366
275
FRC-320
500
1,595
136,533
400
Class
Moment Crack
(ton.m)
Length*
(m)
A
B
A
B
1.45
3.22
1.70
3.61
4-6
4-8
4-6
4-8
Note : * Length of Flat Reinforced Concrete Sheet Piles may exceed usual standard whenever lifted in certain position
Type
Width
(mm)
Cross Section
(cm2)
Section Inertia
(cm4)
Unit Weight
(kg/m)
FPC-220
500
1,095
44,366
FPC-320
500
1,595
136,533
Class
Moment Crack
(ton.m)
Length *
(m)
275
A
B
C
D
E
F
G
3.32
3.70
4.05
4.39
4.71
5.22
5.97
6-9
6 - 10
6 - 10
6 - 11
6 - 11
6 - 11
6 - 12
400
A
B
C
D
E
F
G
H
I
J
K
L
M
N
6.05
6.65
7.24
7.81
8.37
8.91
9.43
9.94
10.43
10.91
11.37
11.81
12.24
13.88
6 - 10
6 - 11
6 - 11
6 - 12
6 - 12
6 - 12
6 - 13
6 - 13
6 - 13
6 - 14
6 - 14
6 - 14
6 - 14
6 - 15
Note : * Length of Flat Prestressed Concrete Sheet Piles may exceed usual standard whenever lifted in certain position
PRODUCT APPLICATION
RETAINING WALL
RIVER NORMALIZATION
UNDERPASS WALL
BREAKWATER STRUCTURE
HEAD OFFICE
Ph. +62 (21) 84973363 (hunting) | Fax. +62 (21) 84973391, 84973392 | E-mail : marketing@wika-beton.co.id | Visit us : http://www.wika-beton.co.id
SALES AREA OFFICE
Medan : Ph. +62 (61) 6627577, 6626225 | Fax. +62 (61) 6628076 Pekan Baru : Ph/Fax. +62 (761) 849909 Palembang : Ph. +62 (711) 712534, 7300399 | Fax. +62 (711) 720093
Jakarta : Ph. +62 (21) 8192808, 8193024 | Fax. +62 (21) 8560694 Semarang : Ph. +62 (24) 8411890, 8318787 | Fax. +62 (24) 8318135, 8318091 Surabaya : Ph. +62 (31) 8478795, 8478796 | Fax. +62 (31) 8435384
Balikpapan : Ph. +62 (542) 875927, 877027 | Fax. +62 (542) 875927 Makassar : Ph. +62 (411) 511761, 4723100, 4723200 | Fax. +62 (411) 511955, 4723166