Beruflich Dokumente
Kultur Dokumente
Particles which lie between 10 m to 2.5 m are termed as Coarse particles whereas particles with
diameter less than 2.5 m are called Fine particles. Fine particles also include ultra-fine particles of size
less than 0.1 m (PM0.1).
EFFECTS OF AIR POLLUTANTS
(in terms of health aspects and environmental aspects)
The effects of various pollutants can be understood in terms of health aspects and environmental aspects.
The effects are summarized in the following table:
Pollutants
Major effects
Health effects
Environmental effects
and
Nitrogen
(NOx)
Particulate
(PM)
matter Respiratory
problems,
liver
fibrosis, Visibility reduction
lung/liver cancer, Heart stroke, Bone
problems
in
Lead (Pb)
Serious effects on central nervous system since it is absorbed rapidly in blood stream,
Anemia, toxic for soft tissues and bones
Ammonia (NH3)
Immediate effects lead to burning of eyes, nose, throat, and respiratory tract. Prolonged
effects result in blindness, lung damage, or
death.
Health Effects
Environmental effects
There are various controlling measures for air pollutants; however for the ease of understanding, it can be
divided into two categories:
I. Control of gaseous air pollutants
II. Control of particulate pollutants
I. Control of gaseous air pollutants
There are essentially two classes of techniques by which gaseous pollutants may be removed from a gas
stream:
a. Sorption of pollutant, for example, through absorption in a liquid or adsorption on a solid surface, and
b. Chemical alteration of the pollutant, usually, through combustion or catalytic treatment.
A. Absorption by liquids
Absorption is one of the most frequently used techniques for controlling the concentration of gaseous
pollutants before they are discharged into the atmosphere. In this process, effluent gases are passed
through absorbers (scrubbers) which contain liquid absorbants that remove one or more of the pollutants
in the gas stream.
under the action of gravity. The solid particulates having higher density than the surrounding gas, settle
under the influence of gravity on the base of the chamber, from where they are removed through the
hoppers.
Advantages:
1. Low initial cost
2. Simple construction
3. Low maintenance cost
4. Dry and continuous disposal of solid particulates
Disadvantages:
1. Large space requirements
2. Only comparatively large particles can be collected.
B. Cyclone separators
A cyclone separator can be defined as a structure, without moving parts in which the velocity of an inlet
gas stream is transformed into a confined vortex from which centrifugal forces tend to drive the
suspended particles to the wall of the cyclone body. Cyclone separators utilize a centrifugal force
generated by a spinning gas stream to separate the particulate matter from the carrier gas. In operation, the
particle laden gas upon entering the cyclone cylinder receives a rotaing motion. The vortex so formed,
develops a centrifugal force, which acts to throw the particles radially towards the wall.Cyclones are used
widely for the control of gas borne particulates in such industrial operations as cement manufacture, feed
and grain processing, food and beverage processing, mineral processing, paper and textile industries, and
wood working industries etc.
Advantages:
1. Low initial cost
2. Simple construction and operation
3. Low maintenance requirements
4. Continuous disposal of solid particulates
Disadvantages:
1. Low collection efficiency for particles below 5-10 m in diameter.
2. Equipment is subject to severe abrasive deterioration.
C. Fabric filters
Filtration is the oldest and generally one of the most versatile and efficient methods for removing
particulate matter from industrial gases. Filters can be classified as either a packed filter or a fabric filter,
depending on the way in which the fibers are held in place. In a packed filter, the fibers are loosely
packed inside an enclosure where the dust laden gas takes a long path on its way through the filter. In a
fabric filter, fibers are woven into a thin layer of fabric (bag filters), usually made from natural, synthetic
metal or glass fibers.
Fabric filters are the most commonly used particle collectors in industry where as packed filters find wide
use in air conditioning and other applications where the dust loading is relatively small.
In principle, the dust laden gas passes through the filter in which the particulates are trapped on to the
fibres by the mechanisms of inertial impaction, direct interception, and diffusion.
Fabric filters find extensive applications in the industries like metallargical industries, foundries, cement
industries, chalk and lime paints, brick works, ceramic industries, flour mills etc.
Advantages:
1. High particle collection efficiencies for all particle sizes, esp. for particles < 10 m in diameter.
2. Simple construction and operation
3. Dry disposal of collected material
4. Retention of finest particles.
Disadvantages:
1. Their application is possible only where process temperature is generally < 285C.
2. High construction, maintenance, and fabric replacement costs.
3. Large size of equipment.
D. Electrostatic Precipitators (ESP)
The electrostatic precipitator is one of the most widely used devices for controlling particulate emissions
at industrial installations. ESPs are particulate collection devices that utilize electrical energy directly to
assist in the removal of the particulate matter. Particles as small as 1/10th of a micron can be removed.
The principle on which this equipment operates is that, when a gas containing aerosols is passed between
two electrodes that are electrically insulated from each other and between which there is a considerable
difference in electric potential, aerosol particles precipitate on the low potential electrode. Actually,
electrostatic precipitation is a physical process by which particles suspended in gas stream are charged
electrically and, under the influence of the electrical field, separated from the gas stream.
ESPs find applications in industries like cement industries, pulp and paper mills, steel plants, non-ferrous
metal industries, petroleum industries, carbon black industries etc.
Advantages:
1. High collection efficiency
2. Particles as small as 0.1 m can be removed.
3. Low maintenance and operating costs
4. Treatment time is negligible
5. There is no limit to solid, liquid, or corrosive chemical usage.
Disadvantages:
1. High initial costs
2. Space requirement is more
3. Possible explosion hazards during collection of combustible gases or particulates
4. Precautions are necessary to maintain safety during operation, as operating voltage is high.
E. Wet Collectors or Scrubbers
These are devices which utilize a liquid to assist in the removal of particulates from the carrier gas stream.
Generally, water is used as the scrubbing liquid. In a wet collector, the dust is agglomerated with water
and then separated from the gas together with the water. The mechanism of particulates removal involves
inertial impaction, direct interception, diffusion, and condensation.
Wet scrubbers are particularly useful,
when, the hot gas must be cooled for some reason
when, addition of a liquid to the gas is harmless or even beneficial
when, the particulate is combustible or any flammable gas is present, even in trace amounts, in the bulk
gas phase
when, a waste water treatment system is available on site with adequate reverse capacity to handle the
liquid effluent
Advantages:
1. Low initial cost
2. Moderately high collection efficiency for small particles
3. Applicable for high temperature installations
4. These can simultaneously remove particulates and gases
5. Effective performance over a wide loading range
6. Small space requirement
Disadvantages:
1. High power consumption for higher efficiency
2. Wet disposal of collected material
3. Very small particles (sub-micron size) may not be captured.
RECENT DEVELOPMENTS
This Section emphasizes the recent developments in the field of "Air Pollution Control".
1. Respirable Dust Sampler (RDS)
2. Air-Shed approach for air pollution mitigation
1. Respirable Dust Sampler (RDS)
The respirable dust fraction is dust that enters the deep lung and is considered to be < 10 m. It causes
serious respiratory problems on continuous inhalation. Respirable dust is sampled using a cyclone dust
sampler designed to sample for a specific fraction of dust at a set flow rate. This particular instrument
uses an improved cyclone with sharper cutoff (D50 at 10 m) to separate the coarser particulates from the
air stream before filtering it on the glass microfibre filter. The cyclone sampler is designed such that
smaller particles are carried onto the filter paper inside the cassette and larger unwanted particles drop
into the pot. By using this instrument, measurement of respirable particulate matter can be done
accurately and total suspended particulate matter (TSPM) can also be assessed by collection of dust
retained in the cyclone cup.
Important specifications of RDS are as follows:
Flow rate
0.9 1.4 m3/min free flow
Particle size
Particles of 10 m collected on filter paper holder. SPM > 10 m are
collected in a separate sampling bottle under the cyclone
Sampling time
28 hours (maximum)
Sampling time record
0 to 9999.99 hrs. recorded on a time totalizer
Automatic sampling
24 hrs programmable timer to automatically shut off the system after preset
time interval
Power requirement
Nominal 220 V, single phase, 50 Hz AC mains supply
Special Features
1. Brushless blower reduces equipment downtime and maintenance effort.
2. Significantly reduced noise.
3. Electromagnetic interference (EMI) to TVs totally eliminated.
4. Provision of light for flow and time reading during night.
5. Toolbox within the instrument.
6. Lockable casters for field convenience.
7. Lockable top cover and gaseous attachment.
8. Improved cabinet design which is more sturdy and durable.
2. 'Air-Shed approach for air pollution mitigation
Air-shed or air quality region is that geographical area which encompasses both the areas air pollution
sources and its receptors. A regional air-shed can be defined as a government covering an entire air
pollution area, so that ideally within such an airshed:
There is a discrete and common air mass, i.e., all air pollution remains within such as air basin and does
not pass out of its boundaries,
All pollution sources and pollution-producing activities are included, and
All the affected population is covered.
However, practically, it is impossible to define such an air drainage area, solely by meteorological criteria.
A regional air-shed is interjurisdictional, often interstate. Rather, a regional air-shed is best related to a
metropolitan area including the central city, its suburbs, and surrounding rural areas. All political
jurisdictions within an air quality region would have the same air quality standards. In general, air-shed
would not be contiguous but would be separated by non-urban hinterland. If two separated regions were
to expand in area in the future until they became contiguous, they would presumably then be merged into
one larger air-shed. Since each air-shed would adopt its own air quality standards, they could differ
among the several regions.
Among the most advantageous and appropriate functions for a regional airshed to undertake would be:
1. An environmental center for research and training
2. A monitoring system on an area-wide basis
3. An emergency alert procedure or a quickly triggered early warning system.
4. The allocation of scarce, low sulfur fuels, during emergencies, or continuously, as a uniform, regional
market.
Special Feature
Air pollution does not respect political boundary lines. Existing local and state agencies deal with air
pollution on a limited, piecemeal and uncoordinated basis, therefore, an areawide agency covering the
entire problem-shed would be the most effective unit to deal with the problem.