Beruflich Dokumente
Kultur Dokumente
n n
3
Our services:
Dependability at your call
We tailor our services to enable Ready where you are. KSB runs
new ways of individually optimizing more than 100 service centres around
our products. They underscore our far- the world. Some 1,900 highly trained
reaching sense of customer responsibil KSB specialists are on call to inspect
ity. That commitment starts before any and maintain your equipment. So you
orders – for example with sound advice can plan for a future free of unwanted
on financing options. And it goes far surprises. And we also provide individual
beyond product arrival. A dependable on-site training sessions. They ensure
partnership with KSB lasts for years. Our that operators can use KSB products and
services to customers include: systems efficiently and profitably, day in,
day out.
• Remote diagnosis
• Revamping Which is how we secure the long-term
• TPM (Total Pump Management)
®
value of our customers’ facilities.
• System engineering
• Advice on life cycle costs
• Financing options
• Teleservice
• Savings potential analysis
4
Our vision:
Moving more, together
Yesterday: Movement with a Today: Impetus from innovations. Tomorrow: Perspectives for
mission. KSB has spent its long history providing partnerships.
When KSB started business in 1871, our technical innovations that help custom Lively dialogue with customers has been
pumps got things moving almost over- ers and partners work more successfully a KSB speciality for over 130 years.
night. From the word go, the company than ever. Mutual respect remains its hallmark.
was an enthusiastic pioneer. The motor
of that dynamism was the sense of con- We gear everything we do to the Our aim is to strengthen this working
tributing to new movement in modern real demands of everyday operations. partnership still further. The benefits
industry. Products, systems, life cycle costs and are mutual, too: we profit from prac-
our steadily growing range of services all tical experience that complements our
That is all history now. But KSB still stays put customers and their processes first. years of development know-how. And
true to its tradition, and continues to This relies on our special concentration so our customers profit from innovative
pioneer remarkable technical skills. of activities – from development to sales products, systems and services that
and marketing. match their demands with precision and
performance.
Partnership is a value whose products keep their value. So moving more together makes doubly good sense. We look
forward to teaming up.
5
Energy Conversion
Building Services
Water Transport
Solids Transport
and Treatment
Automation
Industry
Type / Application Type series Page A
Circulator pumps/hot water service pumps, Rio C / Rio / Rio Z / Riotherm C 16 n n
fixed speed Riotherm 16 n n n
6
Energy Conversion
Building Services
Water Transport
Solids Transport
and Treatment
Automation
Industry
Type / Application Type series Page A
Submersible pumps in discharge tubes Amacan K / Amacan P / Amacan S 36 n n
Mixers/agitators/tank cleaning units Amamix, 36 n n
Amaprop, Amajet, Amaline 37 n n
Pumps for solids-laden fluids Sewatec / Sewabloc 37 n n n
KWP / KWP-Bloc 38 n n n n
WBC 38 n
Slurry pumps
LSA-S 38 n n n
LCC-M 38 n n n
LCC-R 39 n n n
TBC 39 n
LSR / LCV 39 n
FGD 39 n n n
Mega 40 n
HHD 40 n
MHD 40 n
LHD 40 n
MDX 40 n n
ZW 41 n
Self-priming pumps Etaprime L / Etaprime B / BN 41 n n
Submersible borehole pumps S 100D / UPA 100C 42 n n n n
UPA 150C, 200, 200B, 250C, 300, 350 42 n n n
UPZ, BSX-BSF 42 n n n n
High-pressure pumps, fixed/variable speed Movitec V / LHS / VS / VC 43 n n n n n
Movitec PumpDrive 43 n n n n n
Multitec 43 n n n n n
Multitec PumpDrive 43 n n n n n
Axially split pumps Omega 44 n n n n n
RDLO 44 n n n n n
Hygienic pumps for the food, beverage and Vitachrom / Vitacast / Vitacast E 44 n n
pharmaceutical industries Vitaprime / Vitastage / Vitalobe 45 n n
CHTA / CHTC / CHTD 45 n
Pumps for power station conventional
CHTR 46 n
islands
HGB / HGC / HGD 46 n n
HGM 46 n n
YNK / KRHA 46 n
RHD 46 n
LUV / LUVA 47 n
WKT / WKTA / WKTB 47 n
SEZ / SEZT / PHZ / PNZ 47 n n
SNW / PNW 47 n n
SPY 47 n n n
Pumps for power station nuclear islands RER / RSR / PSR 48 n
LUV-Nuclear / RHM 48 n
RVM / RHR / RVR / RUV 49 n
Pumps and pressure exchangers for SalTec System 50 n n
seawater desalination by reverse osmosis SalTec DT 50 n n
RPH-RO 50 n
HGM-RO 50 n
Multitec-RO 50 n n
Automation Page
Control units Controlmatic E.2 51 n n
Cervomatic EDP.2 51 n n
LevelControl 51 n n
UPA Control 51 n n
hyatronic N 51 n n n
Speed control PumpDrive 52 n n n
hyatronic spc 52 n n n
hyatronic mb 52 n n n
Hyamaster ISB 52 n n n
Hyamaster SPS 52 n n n
Monitoring and diagnostic systems PumpMeter 53 n n
Amacontrol 53 n n
7
Etanorm / Etanorm-R / Etanorm PumpDrive
Etaline PumpDrive / Etaline Z PumpDrive
HX (Nikkiso-KSB)
HY (Nikkiso-KSB)
Riotherm C
Rio / Rio Z
Rio-Eco B
Rio-Eco Z
Riotherm
Etaline-R
Rio-Eco
CPK-D
Fluids
HPK-L
Rio C
HPH
HPK
Circulator pumps / hot water service pumps, fixed speed
Activated sludge
Inorganic liquids n n n
Liquefied gas
Lubricants n n
Oils n n n n n n n n n n n
Organic liquids n n n n n n
Polymerizing liquids n n n
Raw sludge
River, lake and ground water n n
Seawater n n
Service water n n n n n n n n n n n
Sewage with faeces
Sewage without faeces n n
Slurries
Slurries (ore, sand, gravel, ash)
Solvents n n n
Swimming-pool water n n n n
Thermal oil n n n n n n n
Toxic liquids n n n
Valuable liquids n n n n
Volatile liquids n n n
Wash water n
Waste water
8
Ama-Drainer 400/10 400/35 500/10/11
Ama-Drainer N 301, 302, 303, 358
Magnochem / Magnochem-Bloc
HN / BN / TN (Nikkiso-KSB)
HT / BT / TT (Nikkiso-KSB)
Hya-Eco K / Hya-Eco VP
Hya-Rain / Hya-Rain N
Ama-Porter F / S / ICS
Ama-Drainer 80, 100
Etaseco / Etaseco-I
Hya-Solo D / DV
Secochem Ex K
Multi Eco-Top
Hya-Rain Eco
Movitec VME
Secochem Ex
Etaseco RVP
Microchem
Hyamat VP
Hya-Solo E
MK / MKY
Hyamat K
Hyamat V
Filtra N
Rotex
CTN
RPH
Ixo
Activated sludge
Domestic water supply systems with automatic control unit / swimming pools
Process pumps
n n n n n n n n n n n n Inorganic liquids
n n n n Liquefied gas
n Lubricants
n n n n n n n n n n n n n Oils
n n n n n n n n n n n n n Organic liquids
n n n n Polymerizing liquids
Raw sludge
n n n n n River, lake and ground water
Seawater
n n n n n n n n n n n n n Service water
n Sewage with faeces
n n n n n n n n n n n n n n Sewage without faeces
Slurries
Slurries (ore, sand, gravel, ash)
n n n n n n n n n n n n Solvents
n n n n n Swimming-pool water
n n n n n n Thermal oil
n n n n n n n n n n n n Toxic liquids
n n n n n n n n n n n n Valuable liquids
n n n n n n n n n n n n n Volatile liquids
Wash water
n n n n n n Waste water
9
Evamatic-Box / Evamatic-Box ICS
Ama-Porter CK Pumping Station
Amarex N CK Pumping Station
Sewatec / Sewabloc
Ama-Drainer-Box
KWP / KWP-Bloc
Etaprime B / BN
mini-Compacta
LCC-M / LCC-R
Amarex KRT
Etaprime L
Amacan K
Compacta
Amacan P
Amarex N
Amacan S
Amaprop
Amamix
Amaline
Amajet
LSA-S
Mega
Fluids
MHD
MDX
WBC
HHD
FGD
LHD
TBC
LCV
LSR
ZW
Activated sludge n n n n n n n
Lifting units / collecting tanks
Slurry pumps
Self-priming pumps
Aggressive liquids n n n n n n n n
Brackish water
Brine n n n
Cleaning agents
Condensate
Coolant
Cooling water n n n
Corrosive liquids n n n n
Destillate
Digested sludge n n n n n
Dipping paints
Drinking water
Explosive liquids
Feed water
Fire-fighting water
Flammable liquids
Fuels
Gas-containing liquids n n n n
Harmful liquids
Heating water
Highly aggressive liquids
High-temperature hot water
Hot water
Hygienic liquids
Industrial service water n n n n n n n n n
Inorganic liquids
Liquefied gas
Lubricants
Oils
Organic liquids
Polymerizing liquids
Raw sludge n n n n n
River, lake and ground water n n n n n n n
Seawater n n n n n n
Service water n n n n n n n n n n n n n n n n
Sewage with faeces n n n n n n n n n n n n n n n
Sewage without faeces n n n n n n n n n n n n n n n n
Slurries n n n n n n n n n n n n n n
Slurries (ore, sand, gravel, ash) n n n n n n n n n n n n n n
Solvents
Swimming-pool water
Thermal oil
Toxic liquids
Valuable liquids
Volatile liquids
Wash water n
Waste water n n n n n n n n n n n n n n n n n n n n
10
Vitachrom / Vitacast / Vitacast E
Vitaprime / Vitastage / Vitalobe
Multitec / Multitec PumpDrive
Movitec V / LHS / VS / VC
YNK / KRHA
Multitec-RO
LUV nuclear
SNW / PNW
PumpMeter
LUV / LUVA
RHR / RVR
UPA 150C
HGM-RO
RPH-RO
Omega
RDLO
CHTR
HGM
RHM
RVM
RHD
RUV
SPY
Activated sludge
Submersible borehole pumps
Pumps for power station conventional islands
High-pressure pumps, fixed / variable speed
n n n n Hot water
n n Hygienic liquids
n n n n n n n n n n n n n n Industrial service water
Inorganic liquids
Liquefied gas
n Lubricants
n n n Oils
n n Organic liquids
Polymerizing liquids
Raw sludge
n n n n n n n n n n n n River, lake and ground water
n n n n n n n n n n n n n Seawater
n n n n n n n n n n n n Service water
n Sewage with faeces
n Sewage without faeces
Slurries
Slurries (ore, sand, gravel, ash)
n n Solvents
n Swimming-pool water
Thermal oil
Toxic liquids
Valuable liquids
n Volatile liquids
n n n Wash water
Waste water
11
Etanorm / Etanorm-R / Etanorm PumpDrive
Etaline PumpDrive / Etaline Z PumpDrive
HX (Nikkiso-KSB)
HY (Nikkiso-KSB)
Riotherm C
Rio / Rio Z
Rio-Eco B
Rio-Eco Z
Riotherm
Etaline-R
Rio-Eco
CPK-D
Applications
HPK-L
Rio C
HPH
HPK
Circulator pumps / hot water service pumps, fixed speed
Air-conditioning systems
Industrial recirculation systems n n n n n n n n n n n n n n n n n n n n n
Irrigation n n n n n
Keeping in suspension
Lowering ground water levels
Maintaining ground water levels
Mining
Mixing
Nuclear power stations n n n n
Paint shops n n
Paper and cellulose industry n n
Petrochemical industry n n n
Pharmaceutical industry
Pipelines and tank farms n n n
Pressure boosting
Process engineering n n n n n n n n
Rainwater harvesting
Recirculation
Refineries n n n n
Seawater desalination / reverse osmosis n n n
Sewage treatment plants n n n n n
Shipbuilding
Sludge disposal
Sludge processing
Snow guns
Spray irrigation n n n n
Sugar industry n n
Swimming pools n n n n n
Thickening
Washing plants
Water extraction n
Water supply n n n n n n n n n n n
Water treatment systems n n
12
Ama-Drainer 400/10 400/35 500/10/11
Ama-Drainer N 301, 302, 303, 358
Magnochem / Magnochem-Bloc
HN / BN / TN (Nikkiso-KSB)
HT / BT / TT (Nikkiso-KSB)
Hya-Eco K / Hya-Eco VP
Hya-Rain / Hya-Rain N
Ama-Porter F / S / ICS
Ama-Drainer 80, 100
Etaseco / Etaseco-I
Hya-Solo D / DV
Secochem Ex K
Multi Eco-Top
Hya-Rain Eco
Movitec VME
Secochem Ex
Etaseco RVP
Microchem
Hyamat VP
Hya-Solo E
MK / MKY
Hyamat K
Hyamat V
Filtra N
Rotex
CTN
RPH
Ixo
Air-conditioning systems
Domestic water supply systems with automatic control unit / swimming pools
n n n n n n
Seal-less pumps
Process pumps
13
Evamatic-Box / Evamatic-Box ICS
Ama-Porter CK Pumping Station
Amarex N CK Pumping Station
Sewatec / Sewabloc
Ama-Drainer-Box
KWP / KWP-Bloc
Etaprime B / BN
mini-Compacta
LCC-M / LCC-R
Amarex KRT
Etaprime L
Amacan K
Compacta
Amacan P
Amarex N
Amacan S
Amaprop
Amamix
Amaline
Amajet
LSA-S
Mega
Applications
MHD
MDX
WBC
HHD
FGD
LHD
TBC
LCV
LSR
ZW
Air-conditioning systems
Lifting units / collecting tanks
Slurry pumps
Self-priming pumps
Aquaculture n n
Boiler circulation
Boiler feed applications
Chemical industry n n n n n
Cleaning of stormwater tanks / storage sewers n n n n n n
Condensate transport
Cooling circuits n
Descaling units n n n n n n n n n n n n n
Dewatering n n n n n n n n n
Disposal n n n n n n n n n n n n
District heating
Dock facilities
Domestic water supply
Drainage n n n n n
Drainage of pits, shafts, etc. n n n
Dredging n n n n n n n n
Fire-fighting systems
Flue gas desulphurization n n n n
Food and beverages industry n n n n n n
Fountains
Heat recovery systems
Heavy oil and coal upgrading n
Homogenization n
Hot water heating systems
Hydraulic solids transport n n n n n n n n n n n n n n
Industrial recirculation systems n n
Irrigation n n n n n n n n
Keeping in suspension n
Lowering ground water levels n n n n
Maintaining ground water levels n n n n
Mining n n n n n n n n n n n n n n
Mixing n
Nuclear power stations
Paint shops n
Paper and cellulose industry n n n n n
Petrochemical industry
Pharmaceutical industry
Pipelines and tank farms
Pressure boosting
Process engineering n
Rainwater harvesting n
Recirculation n
Refineries
Seawater desalination / reverse osmosis n n n n n
Sewage treatment plants n n n n n n n n n n n n n
Shipbuilding
Sludge disposal n n n n n n n n n n n n n
Sludge processing n n n n n n n n n n n n n n n n n
Snow guns n
Spray irrigation
Sugar industry n n n n n n
Swimming pools
Thickening n
Washing plants n n n n
Water extraction n n n n n n
Water supply n n n n n n n
Water treatment systems n n n n n n n n
14
Vitachrom / Vitacast / Vitacast E
Vitaprime / Vitastage / Vitalobe
Multitec / Multitec PumpDrive
Movitec V / LHS / VS / VC
YNK / KRHA
Multitec-RO
LUV nuclear
SNW / PNW
LUV / LUVA
RHR / RVR
UPA 150C
HGM-RO
RPH-RO
Omega
RDLO
CHTR
HGM
RHM
RVM
RHD
RUV
SPY
n n n n Air-conditioning systems
Submersible borehole pumps
Pumps for power station conventional islands
High-pressure pumps, fixed / variable speed
Homogenization
n Hot water heating systems
Hydraulic solids transport
n n n Industrial recirculation systems
n n n n n n n n n n n n n Irrigation
Keeping in suspension
n n n n n Lowering ground water levels
n n n n Maintaining ground water levels
n n n n n Mining
Mixing
n n n n n n n n n n n n n n Nuclear power stations
n n Paint shops
n n Paper and cellulose industry
n n n n n Petrochemical industry
n n Pharmaceutical industry
n Pipelines and tank farms
n n n n n Pressure boosting
n Process engineering
n Rainwater harvesting
Recirculation
n n Refineries
n n n n n n n n n n Seawater desalination / reverse osmosis
Sewage treatment plants
n n n n Shipbuilding
Sludge disposal
Sludge processing
n n n n n n Snow guns
n n n n n n n Spray irrigation
n n n Sugar industry
Swimming pools
Thickening
n n n Washing plants
n n n n n n n n n n n Water extraction
n n n n n n n n n n n n n Water supply
n n n n n n n n n Water treatment systems
15
Circulator pumps / hot water service pumps, fixed speed
Design: Screw-ended dry rotor pump with mechanical seal and fixed speed.
Rp ________________ 1-11/4
Applications: Hot water supply systems, swimming pools, cooling circuits and
Q [m3/h] _________ max. 10
industrial plants.
H [m] _____________ max. 6
p [bar] ___________ max. 10
T [°C] _ ________ -2 to +110
Data for 50 Hz operation
16 Automation possible
Circulator pumps, variable speed
Riotronic P High-efficiency circulator pump with continuously variable differential pressure control
Design: Maintenance-free wet rotor pump with integrated frequency inverter for
Rp ________________ 1-11/4 continuously variable differential pressure control.
Q [m3/h] ________ max. 4.2
Applications: Industrial recirculation systems, air-conditioning systems,
H [m] _____________ max. 6
heat recovery systems and hot water heating systems.
p [bar] ___________ max. 10
T [°C] _ ________ -2 to +110
n [min-1] _______ max. 4230
Riotronic Eco High-efficiency circulator pump with continuously variable differential pressure control
Design: Maintenance-free wet rotor pump with integrated frequency inverter for
Rp ________________ 1-11/4 continuously variable differential pressure control.
Q [m3/h] ________ max. 2.5
Applications: Industrial recirculation systems, air-conditioning systems,
H [m] _____________ max. 5
heat recovery systems and hot water heating systems.
p [bar] ___________ max. 10
T [°C] _ ______ +15 to +110
n [min-1] _______ max. 3500
Rio-Eco High-efficiency circulator pump with continuously variable differential pressure control
Rio-Eco B High-efficiency circulator pump with continuously variable differential pressure control
Rio-Eco Z High-efficiency circulator pump with continuously variable differential pressure control
Design: Maintenance-free wet rotor pump in twin pump design, with integrated
DN ______________ 32 - 80 frequency inverter for continuously variable differential pressure control and IR
Q [m3/h] ________ max. 108 interface for remote control. Optional pump assignment to main or stand-by duty,
H [m] ____________ max. 13 with automatic changeover in the event of a fault, timer-controlled pump change-
p [bar] ___________ max. 10 over or parallel operation; peak load pump started or stopped as required
T [°C] _ _______ -10 to +110 for optimum efficiency.
n [min-1] _______ max. 4800 Applications: Industrial recirculation systems, air-conditioning systems,
cooling circuits, heat recovery systems and hot water heating systems.
Design: Close-coupled, in-line twin circulator pump, pump shaft and motor shaft
DN ______________ 32 - 200 are rigidly coupled.
Q [m3/h] _______ max. 1120
Applications: Hot water heating systems, cooling circuits, air-conditioning
H [m] ____________ max. 77
systems, water and service water supply systems, industrial recirculation systems.
p [bar] ___________ max. 16
T [°C] _ _______ -30 to +140
Data for 50 Hz operation
Design: Close-coupled in-line circulator pump, in twin pump design with motor-
DN ______________ 32 - 200 mounted variable speed system; pump shaft and motor shaft are rigidly coupled.
Q [m3/h] ________ max. 990 Double pump control modules (accessories) enable redundant operation of
H [m] ____________ max. 76 Etaline Z without a higher-level controller.
p [bar] ___________ max. 16
Applications: Hot water heating systems, cooling circuits, air-conditioning
T [°C] _ _______ -10 to +110
systems, water and service water supply systems, industrial recirculation systems.
n [[min-1] _______ max. 4200
Design: Vertical close-coupled, in-line circulator pump with volute casing and
DN ____________ 150 - 350 standardized motor.
Q [m3/h] _______ max. 1900
Applications: Hot water heating systems, cooling circuits, air-conditioning, water
H [m] ____________ max. 93
and service water supply systems, industrial recirculation systems.
p [bar] ___________ max. 25
T [°C] _ _______ -30 to +140
Data for 50 Hz operation
Design: Horizontal, long-coupled, single-stage volute casing pump (pump size 125
DN ______________ 32 - 300 - 500 with two stages) with ratings and main dimensions to EN 733, in back pull-
Q [m3/h] _______ max. 1900 out design, with replaceable shaft sleeves / shaft protecting sleeves and casing
H [m] ___________ max. 102 wear rings. ATEX-compliant version available.
p [bar] ___________ max. 16 Applications: Spray irrigation, irrigation, drainage, district heating, water supply
T [°C] _ ________ max. +140 systems, heating and air-conditioning systems, condensate transport, swimming
Data for 50 Hz operation pools, fire-fighting systems, handling of hot water, cooling water, fire-fighting
water, oil, brine, drinking water, brackish water, service water, etc.
Etachrom BC PumpDrive Close-coupled chrome steel pump with motor-mounted variable speed system
Design: Horizontal, single-stage annular casing pump, with ratings and main
DN _______________ 25 - 80 dimensions to EN 733, with replaceable casing wear rings. ATEX-compliant version
Q [m3/h] ________ max. 260 available.
H [m] ___________ max. 106
Applications: Water supply, spray irrigation, irrigation and drainage systems, hea-
p [bar] ___________ max. 12
ting and air-conditioning systems, fire-fighting systems, handling of drinking water,
T [°C] _ ________ max. +110
service water, hot water, cooling water, swimming pool water, fire-fighting water,
Data for 50 Hz operation
condensate, oil and cleaning agents.
Etachrom NC PumpDrive Standardized chrome steel pump with motor-mounted variable speed system
Design: Horizontal, single-stage annular casing pump, with ratings and main
DN _______________ 25 - 80 dimensions to EN 733, with replaceable casing wear rings and motor-mounted
Q [m3/h] ________ max. 260 variable speed system.
H [m] ___________ max. 106
Applications: Water supply, spray irrigation, irrigation and drainage systems, hea-
p [bar] ___________ max. 12
ting and air-conditioning systems, fire-fighting systems, handling of drinking water,
T [°C] _ ________ max. +110
service water, hot water, cooling water, swimming pool water, fire-fighting water,
n [min-1] _______ max. 3500
condensate, oil and cleaning agents.
Design: Single-stage volute casing pump, ratings to EN 733, for vertical installa-
DN ______________ 32 - 150 tion in closed tanks under atmospheric pressure. Up to an immersion depth of
Q [m3/h] ________ max. 660 2000 mm.
H [m] ___________ max. 102
Applications: Handling of neutral degreasing and phosphatizing solutions, wash
p [bar] ___________ max. 16
water with degreasing agents, dipping paints, etc.
T [°C] _ _________ max. +95
Data for 50 Hz operation
HPK-L Hot water / thermal oil recirculation pump without external cooling
Design: Horizontal, radially split volute casing pump in back pull-out design to
DN ______________ 25 - 250 EN 22 858 / ISO 2858 / ISO 5199, single-stage, single-entry, with radial impeller.
Q [m3/h] _______ max. 1330 Equipped with heat barrier, seal chamber air-cooled by integrated fan impeller, no
H [m] ___________ max. 155 external cooling. ATEX-compliant version available.
p [bar] ___________ max. 40
Applications: Handling of hot water and thermal oil in piping or tank systems,
T [°C] _ _ max. +240 / +350
particularly in medium-sized and large hot water heating systems, forced
Data for 50 Hz operation
circulation boilers, district heating systems, etc.
Design: Horizontal, radially split volute casing pump in back pull-out design to
DN _____________ 150 - 400 EN 22 858 / ISO 2858 / ISO 5199, single-stage, single-entry, with radial impeller.
Q [m3/h] _______ max. 4150 TÜV certification to TRD on option. ATEX-compliant version available.
H [m] ___________ max. 185
Applications: Handling of hot water and thermal oil in piping or tank systems,
p [bar] ___________ max. 40
particularly in medium-sized and large hot water heating systems, forced
T [°C] _ ________ max. +400
circulation boilers, district heating systems, etc.
Data for 50 Hz operation
Design: Horizontal, radially split volute casing pump in back pull-out design,
DN ______________ 40 - 350 single-stage, single-entry, with centreline pump feet and radial impeller.
Q [m3/h] _______ max. 2350 TÜV certification to TRD on option. ATEX-compliant version available.
H [m] ___________ max. 225
Applications: Handling of hot water in high-pressure hot water generation plants
p [bar] __________ max. 110
and for use as boiler feed and recirculation pump.
T [°C] _ ________ max. +320
Data for 50 Hz operation
Automation possible 21
Hot water / thermal oil pumps
Design: Horizontal, long-coupled volute casing pump in back pull-out design with
DN ______________ 32 - 300 ratings and main dimensions to EN 733, single-stage, with replaceable casing wear
Q [m3/h] _______ max. 1900 rings. ATEX-compliant version available.
H [m] ___________ max. 102
Applications: Heat transfer systems (DIN 4754, VDI 3033) or hot water recircula-
p [bar] ___________ max. 16
tion (DIN 4752).
T [°C] _ ________ max. +350
Data for 50 Hz operation
Design: Horizontal, single-stage volute casing pump in back pull-out design with
DN ______________ 32 - 100 ratings and main dimensions to EN 733, or in in-line design, with replaceable
Q [m3/h] ________ max. 280 casing wear rings.
H [m] ____________ max. 67
Applications: Heat transfer systems (DIN 4754) or hot water recirculation.
p [bar] ___________ max. 16
T [°C] _ ________ max. +350
Data for 50 Hz operation
Design: Horizontal, seal-less, single-stage volute casing pump with magnetic drive,
DN____________ 32 - 150 ratings and main dimensions to EN 733, with replaceable casing wear rings.
Q [m3/h]________ max. 660
Applications: Handling of thermal oil in heat transfer systems to DIN 4754.
H [m]__________ max. 102
p [bar]_ _________ max. 16
T [°C]________ max. +350
Data for 50 Hz operation
Design: Horizontal, seal-less, single-stage pump with fully enclosed canned motor,
DN _ __________ 32 - 100 uncooled. ATEX-compliant version available.
Q [m3/h] _ ______ max. 200
Applications: Handling of thermal oils and other hot fluids in heat transfer
H [m] __________ max. 100
systems to DIN 4754.
p [bar] __________ max. 40
T [°C] _ ______ max. +350
Data for 50 Hz operation
also available in 60 Hz
22 Automation possible
Thermal oil pumps with magnetic drive / canned motor
Design: Horizontal, seal-less, single-stage pump with fully enclosed canned motor,
DN_____________ 32 - 80 uncooled, coolable or heatable. ATEX-compliant version available.
Q [m3/h] _ ______ max. 150
Applications: Handling of thermal oils and other hot fluids in heat transfer
H [m] __________ max. 100
systems to DIN 4754.
p [bar] __________ max. 40
T [°C]________ max. +250
Data for 50 Hz operation
also available in 60 Hz
Design: Horizontal, radially split volute casing pump in back pull-out design to
DN ______________ 25 - 400 EN 22 858 / ISO 2858 / ISO 5199, single-stage, single-entry, with radial impeller.
Q [m3/h] _______ max. 4150 Also available as variant with “wet” shaft, conical seal chamber, heatable volute
H [m] ___________ max. 185 casing (CPKN-CHs) and/or semi-open impeller (CPKNO). ATEX-compliant version
p [bar] ___________ max. 25 available.
T [°C] _ ________ max. +400 Applications: Handling of aggressive liquids in the chemical and petrochemical
Data for 50 Hz operation
industries as well as in refinery and fire-fighting systems, handling of brine.
CPKN PumpDrive Standardized chemical pump with reinforced bearing bracket and motor-mounted variable speed system
Design: Horizontal, radially split volute casing pump in back pull-out design to
DN ______________ 25 - 300 EN 22 858 / ISO 2858 / ISO 5199, single-stage, single-entry, with radial impeller.
Q [m3/h] _______ max. 1050 Also available as variant with “wet” shaft, conical seal chamber and/or semi-open
H [m] ___________ max. 220 impeller (CPKNO) with motor-mounted variable speed system.
p [bar] ___________ max. 25
Applications: Handling of aggressive liquids in the chemical and petrochemical
T [°C] _ ________ max. +110
industries as well as in refinery and fire-fighting systems, handling of brine.
n [min-1] _______ max. 3600
Design: Horizontal, radially split volute casing pump in back pull-out design to
DN ______________ 32 - 250 ISO 2858, single-stage, single-entry, with radial impeller and zero-leakage
Q [m3/h] _______ max. 1100 hydrodynamic shaft seal.
H [m] ___________ max. 128
Applications: Handling of liquids in the chemical and petrochemical industry,
p [bar] ___________ max. 25
in refineries and paint shops.
T [°C] _ ________ max. +150
Data for 50 Hz operation
Design: Horizontal / vertical, seal-less volute casing pump in back pull-out design
DN ______________ 32 - 100 with fully enclosed canned motor, low noise emission, with radial impeller, single-
Q [m3/h] ________ max. 250 stage, single-entry, pump casing connecting dimensions to EN 733.
H [m] ___________ max. 100
Applications: Handling of aggressive, flammable, toxic, volatile, or valuable
p [bar] ___________ max. 16
liquids in the chemical and petrochemical industry, in environmental engineering
T [°C] _ ________ max. +140
and the general industry.
Data for 50 Hz operation
Secochem Ex Standardized chemical pump with canned motor and explosion protection
Design: Horizontal, seal-less volute casing pump in back pull-out design with fully
DN ______________ 25 - 100 enclosed canned motor, low noise emission, with radial impeller, single-stage,
Q [m3/h] ________ max. 300 single-entry, casing connecting dimensions to EN 22 858 / ISO 2858.
H [m] ___________ max. 150 Design to ATEX.
p [bar] ___________ max. 25
Applications: Handling of aggressive, flammable, explosive, toxic, volatile or
T [°C] _ ________ max. +130
valuable liquids in the chemical and petrochemical industry, in environmental
Data for 50 Hz operation
engineering and the general industry.
24 Automation possible
Seal-less pumps
Secochem Ex K Standardized chemical pump with canned motor and explosion protection
Design: Horizontal, seal-less volute casing pump in back pull-out design with fully
DN ______________ 25 - 100 enclosed canned motor, low noise emission, with radial impeller, single-stage,
Q [m3/h] ________ max. 300 single-entry, pump casing connecting dimensions to EN 22 858 / ISO 2858, with
H [m] ___________ max. 150 external cooler. Design to ATEX.
p [bar] ___________ max. 25
Applications: Handling of aggressive, flammable, explosive, toxic, volatile or
T [°C] _ ________ max. +400
valuable liquids in the chemical and petrochemical industry, in environmental
Data for 50 Hz operation
engineering and the general industry.
Design: Horizontal (HN) or vertical (BN / TN), seal-less, single-stage pump with
DN ______________ 32 - 300 fully enclosed canned motor, uncooled, coolable or heatable. ATEX-compliant
Q [m3/h] ________ max. 800 version available.
H [m] ___________ max. 200
Applications: Handling of aggressive, flammable, explosive, toxic, volatile or
p [bar] ___________ max. 40
valuable liquids in the chemical and petrochemical industry.
T [°C] _ ________ max. +180
Data for 50 Hz operation
also available in 60 Hz
HT / BT / TT (Nikkiso-KSB) Chemical canned motor pump with explosion-protection for special applications
Design: Horizontal (HT) or vertical (BT /TT), seal-less, single-stage pump with fully
DN ______________ 32 - 300 enclosed canned motor, coolable. ATEX-compliant version available.
Q [m3/h] ________ max. 800
Applications: Handling of aggressive, solids-containing, polymerizing, flammable,
H [m] ___________ max. 200
explosive, toxic, volatile or valuable liquids as well as thermal oils in the chemical
p [bar] ___________ max. 40
and petrochemical industry.
T [°C] _ ________ max. +400
Data for 50 Hz operation
also available in 60 Hz
Design: Horizontal, seal-less pump with fully enclosed canned motor, two-stage
DN _______________ 25 - 40 design in tandem arrangement. ATEX-compliant version available.
Q [m3/h] _________ max. 10
Applications: Handling of aggressive, flammable, explosive, toxic, volatile or
H [m] ___________ max. 300
valuable liquids in the chemical and petrochemical industry. For small flow rates,
p [bar] ___________ max. 40
high discharge heads and low NPSHR.
T [°C] _ ________ max. +150
n [min-1] _______ max. 8400
Data for n = 8400 min-1
Design: Horizontal, seal-less pump with fully enclosed canned motor, multistage.
DN ______________ 40 - 100 ATEX-compliant version available.
Q [m3/h] ________ max. 140
Applications: Handling of aggressive, flammable, explosive, toxic, volatile or
H [m] ___________ max. 450
valuable liquids in the chemical and petrochemical industry. For high discharge
p [bar] ___________ max. 40
heads.
T [°C] _ ________ max. +180
Data for 50 Hz operation
also available in 60 Hz
Automation possible 25
Seal-less pumps
Design: Horizontal, seal-less pump with fully enclosed canned motor, single stage,
DN _______________ 32 - 50 self-priming. ATEX-compliant version available.
Q [m3/h] _________ max. 40
Applications: Handling of aggressive, flammable, explosive, toxic, volatile or
H [m] ____________ max. 60
valuable liquids in the chemical and petrochemical industry. Self-priming pump for
p [bar] ___________ max. 40
draining of tanks and unloading of tanks and tank trucks.
T [°C] _ ________ max. +180
Data for 50 Hz operation
also available in 60 Hz
Process pumps
Design: Horizontal, radially split volute casing pump in back pull-out design to
DN ______________ 25 - 400 API 610, 10th edition, or ISO 13709 (heavy duty), with radial impeller, single-stage,
Q [m3/h] _______ max. 4150 single-entry, centreline pump feet; with inducer, if required. ATEX-compliant
H [m] ___________ max. 270 version available.
p [bar] ___________ max. 51
Applications: Refineries, petrochemical and chemical industry, power stations.
T [°C] _ ________ max. +450
Data for 50 Hz operation
Design: Radially split, vertical shaft submersible pump with double volute for wet
DN ______________ 25 - 250 and dry installation, single- or double-stage, single-entry, with radial impeller;
Q [m3/h] ________ max. 800 heatable model available. ATEX-compliant version available.
H [m] ____________ max. 93
Applications: Handling of chemically aggressive liquids, also slightly contaminated
p [bar] ___________ max. 16
or with a low solids content, in the chemical and petrochemical industry.
T [°C] _ ________ max. +300
Data for 50 Hz operation
Design: Horizontal or vertical canned motor pump to API 685, single-stage, with
DN _______________ 1½ - 6 centreline pump feet; also available with inducer.
Q [m3/h] ________ max. 360
Applications: HNP: for clean liquids; HTP: for hot fluids; HSP / HMP: for contam-
H [m] ___________ max. 220
inated or polymerising fluids; HRP: for fluids with a steep vapour pressure curve
p [bar] ___________ max. 40
such as liquefied gases.
T [°C] _ ________ max. +450
Data for 50 Hz operation
also available in 60 Hz
26 Automation possible
Centrifugal pump for minimal volume flows
Factory-automated 27
Domestic water supply systems
with automatic control unit / swimming pools
Multi Eco-Pro Multistage, self-priming centrifugal pump with automatic control unit
Factory-automated 29
Pressure booster systems
Hya-Eco VP Pressure booster system with continuously variable speed control of each pump
Design: Fully automatic package pressure booster system, with 2 to 3 vertical high-
Rp / DN ____________ 2 / 80 pressure pumps and continuously variable speed adjustment of each pump for fully
Q [m3/h] _________ max. 70 electronic control of the required supply pressure, with two standard volt-free
H [m] ___________ max. 120 changeover contacts for fault indication. Configuration and function to DIN 1988,
p [bar] ___________ max. 12 Part 5. Automated with BoosterControl.
T [°C] _ _________ max. +70
Applications: Residential buildings, hospitals, office buildings, hotels, department
Data for 3500 min-1
stores, industry, and other applications.
Hyamat V Pressure booster system with continuously variable speed adjustment of one pump
Hyamat VP Pressure booster system with continuously variable speed control of each pump
30 Factory-automated
Pressure booster systems
Hyamat IK, IV, IVP Pressure booster system for industrial applications
(ICS) Switchgears • LevelControl (Ama-Porter F/S) Reference no. 2541.51-10 / 2539.51-10 / 2539.52-10 / 2539.53-10
Design: Vertical, single-stage centrifugal pump with discharge to the top and par-
Rp _______________ 1¼ - 2 allel with the pump shaft, pump foot designed as suction strainer. Pump and motor
Q [m3/h] _________ max. 24 are rigidly connected by a support pipe, ready to be plugged in, with 1.5 m power
H [m] ____________ max. 14 cable and level switch.
T [°C] _ _________ max. +90 Applications: Automatic disposal of waste water from buildings, pits and tanks,
Data for 50 Hz operation
lowering of surface water levels and drainage.
arch 2011 –
r sale until M
Ama-Drainer-Box Released fo Ama Draine
r Box. Automatic waste water lifting unit
eded by new
to be supers
Pumping Station CK 800-Eu Pumping station, plastic collecting tank with Amarex N S and Ama-Porter
Factory-automated 33
Lifting units / collecting tanks
Ama-Porter CK Pumping Station Pumping station, plastic collecting tank with Ama-Porter
Amarex N CK Pumping Station Pumping station, plastic collecting tank with Amarex N
arch 2011 –
r sale until M
Evamatic-Box Released fo Ev am atic Box N. Sewage lifting unit
eded by
to be supers
Design: Single-pump or dual-pump sewage lifting unit with one or two Ama-Porter
DN _______________ 50 - 65 submersible waste water pumps with free-flow impeller (F) or cutter (S),
Q [m3/h] _________ max. 40 to EN 12050-1.
H [m] ____________ max. 21
Applications: Disposal of domestic waste water and sewage.
T [°C] _ _________ max. +40
Data for 50 Hz operation
arch 2011 –
r sale until M
Evamatic-Box ICS Released fo atic Box N IC
S. Sewage lifting unit
eded by Evam
to be supers
Design: Single-pump or dual-pump sewage lifting unit with one or two Ama-Porter
DN _______________ 50 - 65 ICS submersible waste water pumps with free-flow impeller (F) or cutter (S) and ICS
Q [m3/h] _________ max. 40 control system.
H [m] ____________ max. 21
Applications: Disposal of domestic waste water and sewage.
T [°C] _ _________ max. +40
Data for 50 Hz operation
34 Factory-automated
Submersible motor pumps
PumpDrive • Hyamaster • Amacontrol • Switchgears • LevelControl Reference no. 2553.5-10 also available in 60 Hz
Amarex KRT dry-installed, with cooling jacket Submersible motor pump DN 100 to DN 700
PumpDrive • Hyamaster • Amacontrol • Switchgears • LevelControl Reference no. 2553.5-10 also available in 60 Hz
Amarex KRT wet/dry-installed, with energy-saving motor Submersible motor pump DN 80 to DN 200
PumpDrive • Hyamaster • Amacontrol • Switchgears • LevelControl Reference no. 2553.5-10 also available in 60 Hz
Automation possible 35
Submersible pumps in discharge tubes
Design: Wet-installed, submersible motor pump with axial propeller in ECB design
DN ___________ 500 - 1500 for installation in discharge tubes, single-stage, single-entry. ATEX-compliant
Q [m3/h] ______ max. 25200 version available.
H [m] ____________ max. 12
Applications: Irrigation and drainage pumping stations, stormwater pumping
T [°C] _ _________ max. +40
stations, handling of raw and clean water in water and effluent treatment plants,
n [min-1] _______ max. 1450
of cooling water in power stations and industrial plants, industrial water supply
Data for 50 Hz operation
systems, water pollution and flood control systems, aquaculture.
Design: Wet-installed submersible motor pump with mixed flow impeller, single-
DN ___________ 650 - 1300 stage, for installation in discharge tubes. ATEX-compliant version available.
Q [m3/h] ______ max. 10800
Applications: Handling of water without stringy substances in irrigation and
H [m] ____________ max. 40
drainage pumping systems, general water supply systems, water pollution and
T [°C] _ _________ max. +30
flood control systems.
n [min-1] _______ max. 1450
Data for 50 Hz operation
36 Automation possible
Mixers / agitators / tank cleaning units
Design: Horizontal or vertical volute casing pump with free-flow (F), single vane
DN ______________ 50 - 700
(E), multi-vane (K) and diagonal single vane (D) impellers, discharge flange to DIN
Q [m3/h] ______ 60 - 10000
and ANSI standards. ATEX-compliant version available.
H [m] ____________ max. 95
p [bar] ___________ max. 10 Applications: Handling of sewage and all types of waste water in waste water
T [°C] _ _________ max. +70 management and industry.
n [min-1] _______ max. 2900
Data for 50 Hz operation
Automation possible 37
Pumps for solids-laden fluids
DN ___ 40 - 900 (max. 1000) Design: Horizontal, radially split volute casing pump in back pull-out or close-
Q [m3/h] ______ max. 15000 coupled design, single-stage, single-entry, available with various impeller types:
_ ______________ (18000) non-clogging impeller, open multi-vane impeller, free-flow impeller.
H [m] ___________ max. 100 ATEX-compliant version available.
p [bar] ___________ max. 10
Applications: Handling of pre-treated sewage, waste water, all types of slurries
T [°C] _ _ +120 (max. +280)
n [min-1] _______ max. 2900 without stringy substances and pulps up to 5 % bone dry.
Data for 50 Hz operation
Slurry pumps
Design: Patented design incorporates state-of-the art hydraulic and wear tech-
nologies for heavy-duty, high-pressure applications. The pump shell is designed to
Q [m3/h] ______ max. 13600 reduce stresses that can cause a structural failure during a pressure surge.
H [m] ____________ max. 80
Applications: Ideal for ore and tailings transport to minimize the effect of sudden
p [bar] ___________ max. 40
pressure spikes.
T [°C] _ ________ max. +120
Design: Premium design hard iron pumps for long wear life pumping severe
slurries. The basic, single-wall construction and heavy section, hard metal wet end
Q [m /h] ______ max. 14000
3
combined with the cartridge bearing assembly provides maximum reliability and
H [m] ____________ max. 90
ease of maintenance.
p [bar] ___________ max. 16
T [°C] _ ________ max. +120 Applications: Pumps are widely used in ore transport, mill discharge, cyclone feed,
tailings and plant process.
Design: The hydraulic wet end consists of three components: a shell or casing,
an impeller and a suction plate/liner to permit easy removal for maintenance and
Q [m3/h] _______ max. 3865
inspections.
H [m] ____________ max. 90
p [bar] ___________ max. 16 Applications: Reliable pumps for high discharge head, mildly corrosive slurries and
T [°C] _ ________ max. +120 a wide range of particle sizes. Used in mineral processing, mine dewatering, ash
and tailings.
38 Automation possible
Slurry pumps
Design: Interchangeable rubber and metal design allows best material choice
for any application. Easy wet end change can adapt existing pumps to new
Q [m /h] _______ max. 3865
3
applications.
H [m] ____________ max. 90
p [bar] ___________ max. 16 Applications: Pumps are suitable for moderate discharge heads, fine particles and
T [°C] _ ________ max. +100 highly corrosive slurries.
Design: Extra heavy-duty pumps with a high-grade rubber lining for hard wearing
applications. The key to the LSR‘s success is its endurance.
Q [m3/h] _______ max. 9000
Applications: Designed for heavy-duty mill circuit and fine grind slurries; specific-
H [m] ____________ max. 60
ally copper, iron ore, gold, aggregate and other abrasive applications.
p [bar] ___________ max. 14
T [°C] _ ________ max. +120
Design: Vertical cantilever, rugged hard metal sump pump with bottom suction
and no submerged bearings. Replaceable wet end parts in metal alloys with a
Q [m /h] _______ max. 1360
3
39
Slurry pumps
Design: Horizontal, end suction, modified volute casing pump includes 3 vane
open design impeller for large solids passage.
Q [m /h] _________ max. 45
3
H [m] ____________ max. 30 Applications: High-performance, low maintenance slurry pump recommended for
p [bar] ___________ max. 24 coarse or fine particles from solids-laden waste water to aggressive slurries of an
T [°C] _ ________ max. +120 abrasive and/or corrosive nature.
Design: Best suited for high-flow, high-head pumping where high production
requires the reduction in the number of pumps.
Q [m3/h] ______ max. 14400
H [m] ____________ max. 90 Applications: Ideal for pipeline booster stations and severe mining duties.
p [bar] ___________ max. 29 Also, as booster or main hull pump on cutter suction dredges.
T [°C] _ ________ max. +120
Design: Designed to provide high flow/medium head with high efficiency for high
volume transportation in long pipelines.
Q [m /h] ______ max. 32000
3
H [m] ____________ max. 80 Applications: Ideal for pipeline booster stations and severe mining duties.
p [bar] ___________ max. 28 Also for hopper dredges or as main pump on cutter dredges.
T [°C] _ ________ max. +120
Design: High-flow/low-head design with balanced NPSHR and sphere passage for
high volume transportation over short distance.
Q [m3/h] ______ max. 21600
H [m] ____________ max. 65 Applications: Ideal for sand & gravel, severe mining, dredge ladder and
p [bar] ___________ max. 17 booster pumps.
T [°C] _ ________ max. +120
Design: The latest technology from GIW provides superior wear life and increased
up-time handling your most aggressive slurry applications.
Q [m3/h] ______ max. 14000
H [m] ____________ max. 90 Applications: Designed for SAG and ball mill discharge duties as well as cyclone
p [bar] ___________ max. 16 feed and screen feed applications in ore mining.
T [°C] _ ________ max. +120
40
Slurry pumps
ZW Slurry pump
Design: Vertical cantilever, rugged hard metal sump pumps with top and bottom
suction, not submerged bearings. Replaceable wet end parts in metal alloys with a
Q [m3/h] ________ max. 400
durable mechanical end.
H [m] ____________ max. 35
p [bar] ___________ max. 10 Applications: Abrasive slurries, dewatering, floor clean up, and process transfer.
T [°C] _ ________ max. +120
Self-priming pumps
Design: Horizontal, self-priming volute casing pump, single-stage, with open multi-
DN ______________ 25 - 100 vane impeller, in close-coupled design, with common pump and motor shaft (B) or
Q [m3/h] ________ max. 130 rigidly connected (BN). ATEX-compliant version available.
H [m] ____________ max. 72
Applications: Handling of pure, contaminated or aggressive liquids not containing
p [bar] ___________ max. 10
abrasive substances and / or solids.
T [°C] _ _________ max. +90
Data for 50 Hz operation
41
Submersible borehole pumps
42 Automation possible
High-pressure pumps, fixed / variable speed
Movitec PumpDrive High-pressure in-line pump with motor-mounted variable speed system
Multitec PumpDrive High-pressure pump in ring-section design with motor-mounted variable speed system
DN ______________ 80 - 350 Design: Single-stage, axially split volute casing pump for horizontal or vertical
Q [m3/h] _______ max. 2880 installation, with double-entry radial impeller, mating flanges to DIN, ISO, BS
H [m] ___________ max. 170 or ANSI.
p [bar] ___________ max. 25 Applications: Handling of raw, pure and service water as well as seawater in
T [°C] _ _________ max. +70 water treatment plants, irrigation and drainage pumping stations, power stations,
n [min-1] _______ max. 2900 fire-fighting systems, shipbuilding and the petrochemical industry.
Data for 50 Hz operation,
higher values available upon request
DN _____________ 350 - 700 Design: Single-stage, axially split volute casing pump for horizontal or vertical
Q [m3/h] ______ max. 10000 installation with double-entry radial impeller, mating flanges to DIN, ISO, BS
H [m] ___________ max. 240 or ANSI.
p [bar] ___________ max. 25 Applications: Handling of raw, pure and service water as well as seawater in
T [°C] _ _________ max. +70 water treatment plants, irrigation and drainage pumping stations, in power
n [min-1] _______ max. 1450 stations, fire-fighting systems, shipbuilding and the petrochemical industry.
Data for 50 Hz operation,
higher values available upon request
44 Automation possible
Hygienic pumps for the food, beverage and pharmaceutical
industries
DN _________ 25 - 200 (1“ - 8“) Design: Sturdy rotary lobe pump in hygienic design, bi-directional operation pos-
Q [m3/h] _____________ max. 300 sible, horizontal and vertical orientation of connections. Hygienic design, all wetted
H [m] _______________ max. 200
components made of 316L stainless steel; various rotor types and process connec-
p [bar] _______________ max. 30
T [°C] ____________ -40 to +200
tions available. Pump set with geared motor.
Viscosity [cP]_______ ≤ 3000000 Applications: Hygienic and gentle handling of sensitive or high-viscosity fluids in
Volume displaced______________ the food, beverage and pharmaceutical industries as well as in the chemical indus-
[litres per revolution]_ __ max. 10,5 try and general process engineering.
Data for 50 Hz operation,
other values available upon request
DN _____________ 100 - 500 Design: Horizontal, high-pressure barrel-type pump with radial impellers, single-
Q [m3/h] _______ max. 3700 and double-entry, multistage, with flanges / weld end nozzles to DIN and ANSI.
H [m] __________ max. 5300 Applications: Handling of feed water and condensate in power stations and
p [bar] __________ max. 560 industrial facilities, generation of pressurized water for bark peeling machines and
T [°C] _ ________ max. +210 descaling equipment.
n [min-1] _______ max. 6750
Data for 50 Hz operation,
higher values available upon request
Automation possible 45
Pumps for power station conventional islands
DN _______________ 50 - 150 Design: Horizontal, high-pressure barrel-type pump with radial impellers, single-
Q [m3/h] ________ max. 900 and double-entry, multistage, with flanges / weld end nozzles to DIN, API 610
H [m] __________ max. 2500 and ANSI.
p [bar] __________ max. 250 Applications: In refineries, in the petrochemical industry and in steam generation
T [°C] _ ________ max. +400 plants.
n [min-1] _______ max. 7000
Data for 50 Hz operation,
higher values available upon request
DN ______________ 40 - 400 Design: Horizontal, radially split, multistage ring-section pump with radial
Q [m3/h] _______ max. 2300 impellers, single- or double-entry.
H [m] __________ max. 5300 Applications: Handling of feed water and condensate in power stations and
p [bar] __________ max. 560 industrial facilities, generation of pressurized water for bark peeling machines,
T [°C] _ ________ max. +210 descaling equipment, snow guns, etc.
n [min-1] _______ max. 7000
Data for 50 Hz operation,
higher values available upon request
DN ______________ 25 - 100 Design: Horizontal, radially split, product-lubricated, multistage ring-section pump
Q [m3/h] ________ max. 274 with radial impellers, axial and radial single-entry inlet.
H [m] __________ max. 1400 Applications: Handling of feed water in power stations, boiler feed water and
p [bar] __________ max. 140 condensate in industrial facilities.
T [°C] _ ________ max. +160
n [min-1] _______ max. 3600
Data for 50 Hz operation,
higher values available upon request
DN _____________ 125 - 600 Design: Horizontal, radially split, single-stage, double-entry boiler feed booster
Q [m3/h] _______ max. 3700 pump (booster system) with single or double cast steel volute casing.
H [m] ___________ max. 280 Applications: Handling of feed water in power stations and industrial facilities.
p [bar] ___________ max. 40
T [°C] _ ________ max. +210
n [min-1] _______ max. 1800
Data for 50 Hz operation,
higher values available upon request
DN _____________ 250 - 400 Design: Horizontal, single-stage, double-entry feed water pump, cast and forged
Q [m3/h] _______ max. 6500 variant.
H [m] __________ max. 1000 Applications: Handling of feed water in steam generation systems of nuclear
p [bar] __________ max. 150 power stations.
T [°C] _ ________ max. +210
n [min-1] _______ max. 6500
Data for 50 Hz operation,
higher values available upon request
also available in 60 Hz
46
Pumps for power station conventional islands
DN _____________ 100 - 550 Design: Vertical spherical casing pump, radial impellers, single-entry, single- to
Q [m3/h] _______ max. 7000 three-stage. Suitable for very high inlet pressures and temperatures. Integrated wet
H [m] ___________ max. 275 winding motor to VDE. Product-lubricated bearings, no need for oil supply systems.
p [bar] __________ max. 320 Design to TRD or ASME.
T [°C] _ ________ max. +420 Applications: Hot water recirculation in forced-circulation, forced-flow and
n [min-1] _______ max. 3600 combined-circulation boilers for very high pressures.
Data for 50 Hz operation,
higher values available upon request
DN ______________ 40 - 300 Design: Vertical, multistage, can-type ring-section pump with radial and mixed
Q [m3/h] _______ max. 1800 flow impellers. Single- and double-entry suction impellers, flanges to DIN or ANSI.
H [m] ___________ max. 340 The can is arranged in a pit below the installation floor. The pump is connected
p [bar] ___________ max. 40 with the structure by means of a baseplate.
T [°C] _ ________ max. +100 Applications: Handling of condensate in power stations and energy systems.
n [min-1] _______ max. 1800
Data for 50 Hz operation,
higher values available upon request
Design: Vertical tubular casing pump with open mixed flow impeller (SEZ), mixed
Q [m3/s] _ ________ max. 22 flow propeller (PHZ) or axial propeller (PNZ). Pump inlet with bellmouth or suction
H [m] ___________ max. 100 elbow, pull-out design available, discharge nozzle arranged above or below floor,
T [°C] _ _________ max. +40 flanges to DIN or ANSI standards available.
n [min-1] ________ max. 980 Applications: Handling of raw, pure, service and cooling water in industry, water
Data for 50 Hz operation,
higher values available upon request
supply systems, in power stations and seawater desalination plants.
DN _____________ 350 - 800 Design: Vertical tubular casing pump with mixed flow impeller (SNW) or axial
Q [m3/h] _______ max. 9000 propeller (PNW), single-stage, with maintenance-free Residur shaft bearings,
H [m] ____________ max. 50 discharge nozzle arranged above or below floor.
p [bar] ___________ max. 10 Applications: Irrigation and drainage systems, stormwater pumping stations,
T [°C] _ _________ max. +60 handling of raw and pure water, water supply systems, handling of cooling water.
n [min-1] _______ max. 1500
Data for 50 Hz operation,
higher values available upon request
DN ___________ 350 - 1200 Design: Long-coupled, single-stage volute casing pump in back pull-out design.
Q [m3/h] ______ max. 21600 Applications: Drainage, irrigation and water supply systems, handling of conden-
H [m] ____________ max. 50 sate, cooling water, service water, etc.
p [bar] ___________ max. 10
T [°C] _ ________ max. +105
n [min-1] _______ max. 1480
Data for 50 Hz operation,
higher values available upon request
47
Pumps for power station nuclear islands
DN _____________ max. 800 Design: Vertical, single-stage reactor coolant pump with forged annular casing
Q [m3/h] ______ max. 40000 plated on the inside, with diffuser, either with own pump thrust bearing or
H [m] ___________ max. 140 supported by motor bearing.
p [bar] __________ max. 175 Applications: Reactor coolant recirculation in nuclear power stations (PWR).
T [°C] _ ________ max. +350
n [min-1] _______ max. 1800
Data for 50 Hz operation,
higher values available upon request
also available in 60 Hz
DN _____________ max. 600 Design: Vertical, single-stage reactor coolant pump, with cast double volute
Q [m3/h] _______ max. 9000 casing, supported by motor bearing.
H [m] ___________ max. 215 Applications: Reactor coolant recirculation in nuclear power stations
p [bar] __________ max. 125 (PWR, PHWR).
T [°C] _ ________ max. +310
n [min-1]________ max. 1800
Data for 50 Hz operation,
higher values available upon request
DN _____________ max. 600 Design: Vertical pump set integrated in the reactor pressure vessel, glandless
Q [m3/h] _______ max. 9000 pump with leak-free, low-maintenance wet winding motor.
H [m] ____________ max. 45 Applications: Reactor coolant recirculation in boiling water reactors (BWR).
p [bar] ___________ max. 75
T [°C] _ ________ max. +300
n [min-1] _______ max. 2000
Data for 50 Hz operation,
higher values available upon request
also available in 60 Hz
Design: Vertical pump with integrated motor, single-entry, one to three stages.
DN ______________ 40 - 600
Suitable for very high inlet pressures and temperatures. Integrated wet winding
Q [m3/h] _______ max. 7000
motor to VDE. Product-lubricated bearings, no need for oil supply systems. Design
H [m] ___________ max. 300
to ASME Section 3, KTA, etc.
p [bar] __________ max. 320
T [°C] _ ________ max. +430 Applications: As reactor water clean-up pump in boiling water reactors, reactor
Data for 50 Hz operation,
coolant pump in boiling water and pressurized water reactors, and as recirculation
higher values available upon request pump in test facilities.
also available in 60 Hz
also available in 60 Hz
48
Pumps for power station nuclear islands
also available in 60 Hz
Design: Horizontal or vertical annular casing pump with forged pressure boundary
DN _____________ max. 500
and diffuser.
Q [m3/h] _______ max. 6000
H [m] ___________ max. 190 Applications: Core flooding, emergency cooling and residual heat removal
p [bar] ___________ max. 63 systems, ancillary systems, acid feed systems and low-pressure feed systems.
T [°C] _ ________ max. +200
n [min-1] _______ max. 3600
Data for 50 Hz operation
also available in 60 Hz
Design: Vertical, single-stage reactor coolant pump. Seal-less design with inte-
DN _____________ max. 710
grated wet winding motor and integrated flywheel. Product-lubricated bearings, no
Q [m3/h] ______ max. 22000
oil supply systems required.
H [m] ___________ max. 111
p [bar] __________ max. 155 Applications: Main coolant circulation in third-generation nuclear power stations.
T [°C] _ ________ max. +350
n [min-1] _______ max. 1800
higher values available upon request
available in 50 Hz and 60 Hz
49
Pumps and pressure exchangers for seawater desalination
by reverse osmsis
Design: Hydraulic system for pressure boosting and energy recovery in reverse
osmosis processes for seawater desalination.
Q [m /day] _______ ≥ 10000
3
p [bar] ___________ max. 80 Components: SalTec® DT pressure exchanger, HGM-RO high-pressure pump,
T [°C] _ _________ max. +40 RPH-RO booster pump and control unit.
Applications: Seawater desalination by reverse osmosis.
also available in 60 Hz
Design: Single-pump control system for starting, stopping and monitoring pumps.
Applications: Water supply systems, in combination with pumps like Multi Eco,
No. of pumps ______ max. 1
Multichrom S, Ixo, S 100D, etc.
Voltage [V] ________ 1∼230
Design: Level control unit for controlling up to two pumps. Direct starting up to
4 kW, star-delta starting up to 22 kW.
No. of pumps _____ max. 2
[kW] _ ___________ max. 22 Applications: Tank drainage via float switches, pneumatic or bubbler control in
Voltage [V] ______ 230 / 400 building services and waste water applications.
higher values available upon request
Design: Pump control system in control cabinet for cascade starting and stopping
of up to 6 pumps on the mains.
No. of pumps ______ max. 6
[kW] _ ________________ 22 Applications: Water supply systems.
Voltage [V] ________ 3∼400
51
Speed control
Design: Self-cooling frequency inverter which allows the motor speed to be varied
continuously by means of standard signals and a field bus. Because PumpDrive is
No. of pumps ______ max. 6
self-cooling, it can be mounted on the motor, on the wall or in a cabinet. Control of up to
FI ______ 1 per pump/motor 6 pumps without an additional controller (with PumpDrive Advanced).
[kW] _ ________________ 45
Applications: Cooling circuits, filters, water supply systems, heating, ventilation and
Voltage [V]___ 3∼380 to 480
air-conditioning systems, spray irrigation systems, boiler feed systems, steam generation
plants, process engineering circuits, cooling lubricant supply systems, service water supply
systems and other process engineering applications.
hyatronic spc Pump control system for continuously variable speed adjustment
Design: Pump control system in control cabinet for asynchronous motors of all
No. of pumps ______ max. 8 types and makes for controlling and monitoring hydraulic systems.
FI_ _______________ max. 2
Applications: Heating, ventilation and air-conditioning systems, water supply and
[kW] _ _______________ 200
drainage systems.
Voltage [V] ________ 3∼400
Hyamaster ISB Pump control system for continuously variable speed adjustment
Design: Control system for pumps with three-phase motors of all types and makes,
consisting of a KSB controller with display and control panel and all required power
No. of pumps ______ max. 8
components.
FI_ _______________ max. 2
[kW] _ _______________ 200 Applications: Industrial and process engineering circuits, service water supply,
Voltage [V]________ 3∼400 cooling and lubrication, energy supply in cogeneration plants, heat transfer and
district heating stations, water extraction and treatment, water supply and waste
water disposal.
Hyamaster SPS Pump control system for continuously variable speed adjustment
Design: Control system for pumps with three-phase motors of all types and
No. of pumps______ max. 4 makes, consisting of a programmable logic controller (PLC) with display and control
FI_ ___________ 1 per pump panel and all required power components housed in a control cabinet.
[kW] _ _______________ 650
Applications: Process engineering circuits, service water supply, cooling and
Voltage [V] ________ 3∼400
lubrication systems, cogeneration plants, heat transfer and district heating stations,
water extraction and treatment, water supply and waste water disposal.
52
Monitoring and diagnostic systems
Design: Monitoring system for submersible waste water pumps with shutdown.
No. of pumps ______ max. 1
Type _ ___________ Amacan
Installation ______ mounting
_ ____________ plate IP20
Voltage _________ 230 V AC
53
Subject to technical modification without prior notice.
Your local KSB representative:
KSB Aktiengesellschaft
Johann-Klein-Straße 9
67227 Frankenthal (Germany)
www.ksb.com