Sie sind auf Seite 1von 54

Pumps Valves Systems

n n

Pumps and Automation 2011


Type series index p. 3
Product portfolio p. 6-7
Overview of applications p . 8 - 1 5

Our high standard:


Creating intelligent solutions

We have supplied generations of


­customers worldwide with pumps, valves,
automation products and services.
A company with that kind of experience
knows that success never stands still.
It flows. And the process that makes
that possible is a running partnership
between developer and user, between
production and practice.

Partners move more together. We


do everything possible to ensure that
our customers always have access to the
ideal product and system solutions. KSB
is a loyal partner. And a strong one:

• Over 130 years’ experience


• Present in more than 100 countries
• More than 14,200 employees
• More than 100 service centres
worldwide
• Approximately 1,900 service specialists
Type series index

for pumps and automation

Amacan K 36 HGB / HGC / HGD 46 Omega 44


Amacan P 36 HGM 46
Amacan S 36 HGM-RO 50 PSR 48
Amacontrol 53 HHD 40 PumpDrive 52
Ama-Drainer-Box 33 HK (Nikkiso-KSB) 25 Pumping Station CK 800-Eu 33
Ama-Drainer N 301 – 358 31 HN/BN/TN (Nikkiso-KSB) 25 PumpMeter 53
Ama-Drainer 400 – 500 31 HPH 21
Ama-Drainer 80, 100 31 HPK 21 RDLO 44
Amajet 37 HPK-L 21 RER 48
Amaline 37 HT/BT/TT (Nikkiso-KSB) 25 RHD 46
Amamix 36 HX (Nikkiso-KSB) 22 RHM 48
Ama-Porter F / S / ICS 32 HY (Nikkiso-KSB) 23 RHR / RVR 49
Ama-Porter CK Hya-Eco K 30 Rio 16
Pumping Station 34 Hya-Eco VP 30 Rio C 16
Amaprop 37 Hyamaster ISB 52 Rio Z 16
Amarex KRT 35 Hyamaster SPS 52 Rio-Eco 17
Amarex KRT dry-installed 35 Hyamat IK, IV, IVP 31 Rio-Eco B 17
Amarex KRT Hyamat K 30 Rio-Eco Z 17
wet/dry-installed 35 Hyamat V 30 Riotherm 16
Amarex N 35 Hyamat VP 30 Riotherm C 16
Amarex N CK Hya-Rain / Hya-Rain N 27 Riotronic Eco 17
Pumping Station 34 Hya-Rain Eco 27 Riotronic P 17
API series (Nikkoso-KSB) 26 Hya-Solo E 29 Rotex 32
Hya-Solo D 29 RPH 26
Cervomatic EDP.2 51 Hya-Solo DV 29 RPH-RO 50
CHTA / CHTC / CHTD 45 hyatronic N 51 RSR 48
CHTR 46 hyatronic mb 52 RUV 49
Compacta 33 hyatronic spc 52 RVM 49
Controlmatic E.2 51
CPK-D 23 Ixo 28 S 100D / UPA 100C 42
CPKN 23 SalTec System 50
CPKN PumpDrive 23 KWP / KWP-Bloc 38 SalTec DT 50
CTN 26 Secochem Ex 24
LCC-M 38 Secochem Ex K 25
DN (Nikkiso-KSB) 26 LCC-R 39 Sewatec / Sewabloc 37
LCV 39 SEZ / SEZT / PHZ / PNZ 47
Etabloc 19 Level Control 51 SNW / PNW 47
Etabloc Pump­­Drive 20 LHD 40 SPY 47
Etabloc SYT / Etaline SYT 22 LSA-S 38
Etachrom BC 20 LSR 39 TBC 39
Etachrom BC PumpDrive 20 LUV / LUVA 47
Etachrom NC 20 LUV-Nuclear 48 UPA 150C 42
Etachrom NC PumpDrive 20 UPA 200, 200B, 250C 42
Etaline 18 Magnochem 24 UPA 300, 350 42
Etaline PumpDrive 18 Magnochem-Bloc 24 UPA Control 51
Etaline-R 19 Mega 40 UPZ, BSX-BSF 42
Etaline Z 18 MDX 40
Etaline Z PumpDrive 18 MHD 40 Vitachrom 44
Etamagno SY / SYI / Bloc SY 22 Microchem 27 Vitacast / Vitacast E 44
Etanorm / Etanorm-R 19 mini-Compacta 33 Vitalobe 45
Etanorm Pump­­Drive 19 MK / MKY 32 Vitaprime 45
Etanorm GPV / CPV 21 Movitec PumpDrive 43 Vitastage 45
Etanorm SYT / RSY 22 Movitec VME 28 VN (Nikkiso-KSB) 25
Etaprime B / BN 41 Movitec V / LHS / VS / VC 43
Etaprime L 41 Multi Eco 28 WBC 38
Etaseco / Etaseco-I 24 Multi Eco-Pro 28 WKT / WKTA / WKTB 47
Etaseco RVP 24 Multi Eco-Top 28
Evamatic-Box 34 Multitec 43 YNK / KRHA 46
Evamatic-Box ICS 34 Multitec PumpDrive 43
Multitec-RO 50 ZW 41
Filtra N 29
FGD 39

3
Our services:
Dependability at your call

We tailor our services to enable Ready where you are. KSB runs
new ways of individually optimizing more than 100 service centres around
our products. They underscore our far- the world. Some 1,900 highly trained
reaching sense of customer responsibil­ KSB specialists are on call to inspect
ity. That commitment starts before any and maintain your equipment. So you
orders – for example with sound advice can plan for a future free of unwanted
on financing options. And it goes far surprises. And we also provide individual
beyond product arrival. A dependable on-site training sessions. They ensure
partnership with KSB lasts for years. Our that operators can use KSB products and
services to customers include: systems efficiently and profitably, day in,
day out.
• Remote diagnosis
• Revamping Which is how we secure the long-term
• TPM (Total Pump Management)
®
value of our customers’ facilities.
• System engineering
• Advice on life cycle costs
• Financing options
• Teleservice
• Savings potential analysis

4
Our vision:
Moving more, together

Yesterday: Movement with a Today: Impetus from innovations. Tomorrow: Perspectives for
mission. KSB has spent its long history providing partnerships.
When KSB started business in 1871, our technical innovations that help custom­ Lively dialogue with customers has been
pumps got things moving almost over- ers and partners work more successfully a KSB speciality for over 130 years.
night. From the word go, the company than ever. Mutual respect remains its hallmark.
was an enthusiastic pioneer. The motor
of that dynamism was the sense of con- We gear everything we do to the Our aim is to strengthen this working
tributing to new movement in modern real demands of everyday operations. partnership still further. The benefits
industry. Products, systems, life cycle costs and are mutual, too: we profit from prac-
our steadily growing range of services all tical experience that complements our
That is all history now. But KSB still stays put customers and their processes first. years of development know-how. And
true to its tradition, and continues to This relies on our special concentration so our customers profit from innovative
pioneer remarkable technical skills. of activities – from development to sales products, systems and services that
and marketing. match their demands with precision and
perform­ance.

Partnership is a value whose products keep their value. So moving more together makes doubly good sense. We look
forward to teaming up.

5
Energy Conversion

Building Services
Water Transport

Solids Transport
and Treatment
Automation

Industry
Type / Application Type series Page A
Circulator pumps/hot water service pumps, Rio C / Rio / Rio Z / Riotherm C 16 n n
fixed speed Riotherm 16 n n n

Circulator pumps, variable speed Riotronic P 17 n n


Riotronic Eco 17 n n n
Rio-Eco / Rio-Eco B / Rio-Eco Z 17 n n n
In-line pumps with fixed/variable speed Etaline / Etaline Z 18 n n n
drive Etaline PumpDrive / Etaline Z PumpDrive 18 n n n n
Etaline-R 19 n n n
Standardized/close-coupled pumps, fixed/ Etanorm / Etanorm-R 19 n n n n n
variable speed Etanorm PumpDrive 19 n n n n n
Etabloc 19 n n n n n
Etabloc PumpDrive 20 n n n n n
Etachrom BC 20 n n n n n
Etachrom BC PumpDrive 20 n n n n n
Etachrom NC 20 n n n n n
Etachrom NC PumpDrive 20 n n n n n
Etanorm GPV / CPV 21 n n n n
Hot water pumps HPK-L / HPK / HPH 21 n n n n
Hot water/thermal oil pumps Etanorm SYT / RSY 22 n n n
Etabloc SYT / Etaline SYT 22 n n n
Thermal oil pumps with magnetic drive / Etamagno SY / SYI / Bloc SY 22 n n
canned motor HX (Nikkiso-KSB) 22 n
HY (Nikkiso-KSB) 23 n
Standardized chemical pumps CPKN 23 n n n
CPKN PumpDrive 23 n n n
CPK-D 23 n n
Magnochem 24 n n n
Seal-less pumps
Magnochem-Bloc 24 n n
Etaseco / Etaseco-I 24 n n n n n
Etaseco RVP 24 n n n n n
Secochem Ex 24 n n n
Secochem Ex K 25 n n n
HN / BN / TN (Nikkiso-KSB) 25 n n
HT / BT / TT (Nikkiso-KSB) 25 n n
HK (Nikkiso-KSB) / VN (Nikkiso-KSB 25 n n
DN (Nikkiso-KSB) 26 n
Process pumps RPH 26 n n n
CTN 26 n
API series (Nikkiso-KSB) 26 n
Centrifugal pump for minimal volume flows Microchem 27 n n
Rainwater harvesting systems Hya-Rain / Hya-Rain N 27 n n n
Hya-Rain Eco 27 n n n
Domestic water supply systems with Multi Eco 28 n n n n
automatic control unit/swimming pools Multi Eco-Pro 28 n n
Multi Eco-Top 28 n n n n
Movitec VME 28 n n n n
Ixo 28 n n n n
Filtra N 29 n
Pressure booster systems Hya-Solo E / D / DV 29 n n n n
Hya-Eco K / Hya-Eco VP 30 n n n n
Hyamat K / Hyamat V / Hyamat VP 30 n n n n
Hyamat IK, IV, IVP 31 n n n
Drainage pumps/waste water pumps Ama-Drainer N 301, 302, 303, 358 31 n n
Ama-Drainer 400/10 400/35 500/10/11 31 n n n
Ama-Drainer 80, 100 31 n n
Ama-Porter F / S 32 n n
Ama-Porter ICS 32 n n
Rotex 32 n n
MK / MKY 32 n n n
Lifting units/collection tanks Ama-Drainer-Box 33 n n
mini-Compacta 33 n n
Compacta 33 n n n
Pumping Station CK 800-Eu 33 n n
Ama-Porter CK Pumping Station 34 n n
Amarex N CK Pumping Station 34 n n
Evamatic-Box 34 n
Evamatic-Box ICS 34 n n
Submersible motor pumps Amarex N 35 n n n n
Amarex KRT 35 n n n n
Amarex KRT dry-installed 35 n n n n
Amarex KRT wet/dry-installed 35 n n n n

Factory-automated Automation possible

6
Energy Conversion

Building Services
Water Transport

Solids Transport
and Treatment
Automation

Industry
Type / Application Type series Page A
Submersible pumps in discharge tubes Amacan K / Amacan P / Amacan S 36 n n
Mixers/agitators/tank cleaning units Amamix, 36 n n
Amaprop, Amajet, Amaline 37 n n
Pumps for solids-laden fluids Sewatec / Sewabloc 37 n n n
KWP / KWP-Bloc 38 n n n n
WBC 38 n
Slurry pumps
LSA-S 38 n n n
LCC-M 38 n n n
LCC-R 39 n n n
TBC 39 n
LSR / LCV 39 n
FGD 39 n n n
Mega 40 n
HHD 40 n
MHD 40 n
LHD 40 n
MDX 40 n n
ZW 41 n
Self-priming pumps Etaprime L / Etaprime B / BN 41 n n
Submersible borehole pumps S 100D / UPA 100C 42 n n n n
UPA 150C, 200, 200B, 250C, 300, 350 42 n n n
UPZ, BSX-BSF 42 n n n n
High-pressure pumps, fixed/variable speed Movitec V / LHS / VS / VC 43 n n n n n
Movitec PumpDrive 43 n n n n n
Multitec 43 n n n n n
Multitec PumpDrive 43 n n n n n
Axially split pumps Omega 44 n n n n n
RDLO 44 n n n n n
Hygienic pumps for the food, beverage and Vitachrom / Vitacast / Vitacast E 44 n n
pharmaceutical industries Vitaprime / Vitastage / Vitalobe 45 n n
CHTA / CHTC / CHTD 45 n
Pumps for power station conventional
CHTR 46 n
islands
HGB / HGC / HGD 46 n n
HGM 46 n n
YNK / KRHA 46 n
RHD 46 n
LUV / LUVA 47 n
WKT / WKTA / WKTB 47 n
SEZ / SEZT / PHZ / PNZ 47 n n
SNW / PNW 47 n n
SPY 47 n n n
Pumps for power station nuclear islands RER / RSR / PSR 48 n
LUV-Nuclear / RHM 48 n
RVM / RHR / RVR / RUV 49 n
Pumps and pressure exchangers for SalTec System 50 n n
seawater desalination by reverse osmosis SalTec DT 50 n n
RPH-RO 50 n
HGM-RO 50 n
Multitec-RO 50 n n

Automation Page
Control units Controlmatic E.2 51 n n
Cervomatic EDP.2 51 n n
LevelControl 51 n n
UPA Control 51 n n
hyatronic N 51 n n n
Speed control PumpDrive 52 n n n
hyatronic spc 52 n n n
hyatronic mb 52 n n n
Hyamaster ISB 52 n n n
Hyamaster SPS 52 n n n
Monitoring and diagnostic systems PumpMeter 53 n n
Amacontrol 53 n n

Factory-automated Automation possible

7
Etanorm / Etanorm-R / Etanorm PumpDrive
Etaline PumpDrive / Etaline Z PumpDrive

Etachrom NC / Etachrom NC PumpDrive


Etachrom BC / Etachrom BC PumpDrive
Etabloc / Etabloc PumpDrive

Etamagno SY / SYI / Bloc SY


Riotronic P / Riotronic Eco
Pumps

Etabloc SYT / Etaline SYT

CPKN / CPKN PumpDrive


Etanorm GPV / CPV

Etanorm SYT / RSY


Etaline / Etaline Z

HX (Nikkiso-KSB)
HY (Nikkiso-KSB)
Riotherm C
Rio / Rio Z

Rio-Eco B
Rio-Eco Z
Riotherm

Etaline-R
Rio-Eco

CPK-D
Fluids

HPK-L
Rio C

HPH
HPK
Circulator pumps / hot water service pumps, fixed speed
Activated sludge

Hot water / thermal oil pumps


Circulator pumps, variable speed

In-line pumps with fixed / variable speed drive

Standardized / close-coupled pumps, fixed / variable speed

Hot water pumps

Thermal oil pumps with magnetic drive / canned motor

Standardized chemical pumps


Aggressive liquids n n n
Brackish water n n n
Brine n n n n n
Cleaning agents n n n n n n
Condensate
Coolant
Cooling water n n n n n n n n n n n n n n n n n n
Corrosive liquids n n
Destillate n n n n n
Digested sludge
Dipping paints n n
Drinking water n n n n n n n n
Explosive liquids n n n
Feed water n n n
Fire-fighting water n n n
Flammable liquids n n n
Fuels n
Gas-containing liquids n
Harmful liquids n n n
Heating water n n n n n n n n n n n
Highly aggressive liquids n n n n n
High-temperature hot water n n n n n n n n n n n n n n
Hot water n n n n n n n n n n n n n n n n n n n n
Hygienic liquids
Industrial service water n n n n n n n n n n n


Inorganic liquids n n n
Liquefied gas
Lubricants n n
Oils n n n n n n n n n n n
Organic liquids n n n n n n
Polymerizing liquids n n n
Raw sludge
River, lake and ground water n n
Seawater n n
Service water n n n n n n n n n n n
Sewage with faeces
Sewage without faeces n n
Slurries
Slurries (ore, sand, gravel, ash)
Solvents n n n
Swimming-pool water n n n n
Thermal oil n n n n n n n
Toxic liquids n n n
Valuable liquids n n n n
Volatile liquids n n n
Wash water n
Waste water

8
Ama-Drainer 400/10 400/35 500/10/11
Ama-Drainer N 301, 302, 303, 358
Magnochem / Magnochem-Bloc

HN / BN / TN (Nikkiso-KSB)
HT / BT / TT (Nikkiso-KSB)

Multi Eco / Multi Eco-Pro


API series (Nikkiso-KSB)

Hya-Eco K / Hya-Eco VP
Hya-Rain / Hya-Rain N

Ama-Porter F / S / ICS
Ama-Drainer 80, 100
Etaseco / Etaseco-I

Hyamat IK, IV, IVP


DN (Nikkiso-KSB)
VN (Nikkiso-KSB)
HK (Nikkiso-KSB)

Hya-Solo D / DV
Secochem Ex K

Multi Eco-Top
Hya-Rain Eco

Movitec VME
Secochem Ex
Etaseco RVP

Microchem

Hyamat VP
Hya-Solo E

MK / MKY
Hyamat K
Hyamat V
Filtra N

Rotex
CTN
RPH

Ixo
Activated sludge











Domestic water supply systems with automatic control unit / swimming pools










Process pumps

Centrifugal pump for minimal volume flows

Rainwater harvesting systems

Pressure booster systems

Drainage pumps / waste water pumps


n n n n n n n n n n n n n n n Aggressive liquids
Brackish water
n n n n n n n n n n Brine
n n n n n n n n n n Cleaning agents
n n Condensate
n Coolant
n n n n n n n n n n Cooling water
n n n n n n n n Corrosive liquids
n n n n n n n n n n Destillate
Digested sludge
n n n n n Dipping paints
n n n n n n n n n n n n n n n n n n n Drinking water
n n n n n n n n n n Explosive liquids
Feed water
n Fire-fighting water
n n n n n n n n n n Flammable liquids
n n n n n n n n n Fuels
Gas-containing liquids
n n n n n n n n n n n n Harmful liquids
n Heating water
Seal-less pumps

n n n n n n n n n n n n Highly aggressive liquids


n n n n n n High-temperature hot water
n n n n n n Hot water
Hygienic liquids
n n n n n n n n n n n n n Industrial service water


n n n n n n n n n n n n Inorganic liquids
n n n n Liquefied gas
n Lubricants
n n n n n n n n n n n n n Oils
n n n n n n n n n n n n n Organic liquids
n n n n Polymerizing liquids
Raw sludge
n n n n n River, lake and ground water
Seawater
n n n n n n n n n n n n n Service water
n Sewage with faeces
n n n n n n n n n n n n n n Sewage without faeces
Slurries
Slurries (ore, sand, gravel, ash)
n n n n n n n n n n n n Solvents
n n n n n Swimming-pool water
n n n n n n Thermal oil
n n n n n n n n n n n n Toxic liquids
n n n n n n n n n n n n Valuable liquids
n n n n n n n n n n n n n Volatile liquids
Wash water
n n n n n n Waste water

9
Evamatic-Box / Evamatic-Box ICS
Ama-Porter CK Pumping Station
Amarex N CK Pumping Station

Amarex KRT wet/dry-installed


Pumping Station CK 800-Eu

Amarex KRT dry-installed


Pumps

Sewatec / Sewabloc
Ama-Drainer-Box

KWP / KWP-Bloc

Etaprime B / BN
mini-Compacta

LCC-M / LCC-R
Amarex KRT

Etaprime L
Amacan K
Compacta

Amacan P
Amarex N

Amacan S

Amaprop
Amamix

Amaline
Amajet

LSA-S

Mega
Fluids

MHD

MDX
WBC

HHD
FGD

LHD
TBC

LCV
LSR

ZW
Activated sludge n n n n n n n



Lifting units / collecting tanks

Submersible motor pumps

Submersible pumps in discharge tubes

Mixers / agitators / tank cleaning units

Pumps for solids-laden fluids

Slurry pumps

Self-priming pumps
Aggressive liquids n n n n n n n n
Brackish water
Brine n n n
Cleaning agents
Condensate
Coolant
Cooling water n n n
Corrosive liquids n n n n
Destillate
Digested sludge n n n n n
Dipping paints
Drinking water
Explosive liquids
Feed water
Fire-fighting water
Flammable liquids
Fuels
Gas-containing liquids n n n n
Harmful liquids
Heating water
Highly aggressive liquids
High-temperature hot water


Hot water
Hygienic liquids
Industrial service water n n n n n n n n n
Inorganic liquids
Liquefied gas
Lubricants
Oils
Organic liquids
Polymerizing liquids
Raw sludge n n n n n
River, lake and ground water n n n n n n n
Seawater n n n n n n
Service water n n n n n n n n n n n n n n n n
Sewage with faeces n n n n n n n n n n n n n n n
Sewage without faeces n n n n n n n n n n n n n n n n
Slurries n n n n n n n n n n n n n n
Slurries (ore, sand, gravel, ash) n n n n n n n n n n n n n n
Solvents
Swimming-pool water
Thermal oil
Toxic liquids
Valuable liquids
Volatile liquids
Wash water n
Waste water n n n n n n n n n n n n n n n n n n n n

10
Vitachrom / Vitacast / Vitacast E
Vitaprime / Vitastage / Vitalobe
Multitec / Multitec PumpDrive
Movitec V / LHS / VS / VC

SEZ / SEZT / PHZ / PNZ


UPA 200, 200B, 250C

CHTA / CHTC / CHTD

WKT / WKTA / WKTB


Movitec PumpDrive
S 100D / UPA 100C

HGB / HGC / HGD

RER / RSR / PSR


UPA 300, 350
UPZ, BSX-BSF

YNK / KRHA

Multitec-RO
LUV nuclear
SNW / PNW

PumpMeter
LUV / LUVA

RHR / RVR
UPA 150C

HGM-RO
RPH-RO
Omega
RDLO

CHTR

HGM

RHM
RVM
RHD

RUV
SPY
Activated sludge
Submersible borehole pumps






Pumps for power station conventional islands











High-pressure pumps, fixed / variable speed

Axially split pumps

Hygienic pumps for the food, beverage and pharmaceutical industries

Pumps for power station nuclear islands

Pumps for seawater desalination by reverse osmosis

Monitoring and diagnostic systems


Aggressive liquids
n n n n Brackish water
n n n Brine
n n Cleaning agents
n n n n n n Condensate
n n n n n n Coolant
n n n n n n n n n n n n n n n Cooling water
Corrosive liquids
n n n Destillate
Digested sludge
Dipping paints
n n n n n n n n n n n Drinking water
Explosive liquids
n n n n n n n n n Feed water
n n n n n n n n n Fire-fighting water
n Flammable liquids
n n Fuels
Gas-containing liquids
Harmful liquids
n n Heating water
Highly aggressive liquids
n n n n n n n n n n n High-temperature hot water


n n n n Hot water
n n Hygienic liquids
n n n n n n n n n n n n n n Industrial service water
Inorganic liquids
Liquefied gas
n Lubricants
n n n Oils
n n Organic liquids
Polymerizing liquids
Raw sludge
n n n n n n n n n n n n River, lake and ground water
n n n n n n n n n n n n n Seawater
n n n n n n n n n n n n Service water
n Sewage with faeces
n Sewage without faeces
Slurries
Slurries (ore, sand, gravel, ash)
n n Solvents
n Swimming-pool water
Thermal oil
Toxic liquids
Valuable liquids
n Volatile liquids
n n n Wash water
Waste water

11
Etanorm / Etanorm-R / Etanorm PumpDrive
Etaline PumpDrive / Etaline Z PumpDrive

Etachrom NC / Etachrom NC PumpDrive


Etachrom BC / Etachrom BC PumpDrive
Etabloc / Etabloc PumpDrive

Etamagno SY / SYI / Bloc SY


Riotronic P / Riotronic Eco
Pumps

Etabloc SYT / Etaline SYT

CPKN / CPKN PumpDrive


Etanorm GPV / CPV

Etanorm SYT / RSY


Etaline / Etaline Z

HX (Nikkiso-KSB)
HY (Nikkiso-KSB)
Riotherm C
Rio / Rio Z

Rio-Eco B
Rio-Eco Z
Riotherm

Etaline-R
Rio-Eco

CPK-D
Applications

HPK-L
Rio C

HPH
HPK
Circulator pumps / hot water service pumps, fixed speed
Air-conditioning systems

Hot water / thermal oil pumps


n n n n n n n n n n n n n n n n

Circulator pumps, variable speed

In-line pumps with fixed / variable speed drive

Standardized / close-coupled pumps, fixed / variable speed

Hot water pumps

Thermal oil pumps with magnetic drive / canned motor

Standardized chemical pumps


Aquaculture
Boiler circulation n n n
Boiler feed applications n n n
Chemical industry n n n n n n
Cleaning of stormwater tanks / storage sewers
Condensate transport n n n n n n n n n
Cooling circuits n n n n n n n n n n n n n n n
Descaling units
Dewatering n n n n n
Disposal
District heating n n n n n n n n n
Dock facilities
Domestic water supply
Drainage
Drainage of pits, shafts, etc.
Dredging
Fire-fighting systems n n n
Flue gas desulphurization
Food and beverages industry n n n n n n n n n n n
Fountains
Heat recovery systems n n n n n n n n
Heavy oil and coal upgrading n
Homogenization
Hot water heating systems n n n n n n n n n n n n n n
Hydraulic solids transport


Industrial recirculation systems n n n n n n n n n n n n n n n n n n n n n
Irrigation n n n n n
Keeping in suspension
Lowering ground water levels
Maintaining ground water levels
Mining
Mixing
Nuclear power stations n n n n
Paint shops n n
Paper and cellulose industry n n
Petrochemical industry n n n
Pharmaceutical industry
Pipelines and tank farms n n n
Pressure boosting
Process engineering n n n n n n n n
Rainwater harvesting
Recirculation
Refineries n n n n
Seawater desalination / reverse osmosis n n n
Sewage treatment plants n n n n n
Shipbuilding
Sludge disposal
Sludge processing
Snow guns
Spray irrigation n n n n
Sugar industry n n
Swimming pools n n n n n
Thickening
Washing plants
Water extraction n
Water supply n n n n n n n n n n n
Water treatment systems n n

12
Ama-Drainer 400/10 400/35 500/10/11
Ama-Drainer N 301, 302, 303, 358
Magnochem / Magnochem-Bloc

HN / BN / TN (Nikkiso-KSB)
HT / BT / TT (Nikkiso-KSB)

Multi Eco / Multi Eco-Pro


API series (Nikkiso-KSB)

Hya-Eco K / Hya-Eco VP
Hya-Rain / Hya-Rain N

Ama-Porter F / S / ICS
Ama-Drainer 80, 100
Etaseco / Etaseco-I

Hyamat IK, IV, IVP


DN (Nikkiso-KSB)
VN (Nikkiso-KSB)
HK (Nikkiso-KSB)

Hya-Solo D / DV
Secochem Ex K

Multi Eco-Top
Hya-Rain Eco

Movitec VME
Secochem Ex
Etaseco RVP

Microchem

Hyamat VP
Hya-Solo E

MK / MKY
Hyamat K
Hyamat V
Filtra N

Rotex
CTN
RPH

Ixo
Air-conditioning systems











Domestic water supply systems with automatic control unit / swimming pools










n n n n n n
Seal-less pumps

Process pumps

Centrifugal pump for minimal volume flows

Rainwater harvesting systems

Pressure booster systems

Drainage pumps / waste water pumps


Aquaculture
n Boiler circulation
Boiler feed applications
n n n n n n n n n n n n n Chemical industry
Cleaning of stormwater tanks / storage sewers
n n n n n n n n n n n Condensate transport
n n n n n n n Cooling circuits
Descaling units
n n n n n n Dewatering
n n n n n n Disposal
n n n n n n n District heating
Dock facilities
n n n n n n n n n Domestic water supply
n n n n n n Drainage
n n n n n Drainage of pits, shafts, etc.
Dredging
n Fire-fighting systems
Flue gas desulphurization
n n n n n n Food and beverages industry
n Fountains
Heat recovery systems
n Heavy oil and coal upgrading
Homogenization
n n n n n Hot water heating systems
Hydraulic solids transport



n n n n n n n n n n Industrial recirculation systems


n n n n n n n n n n n n n Irrigation
Keeping in suspension
Lowering ground water levels
Maintaining ground water levels
Mining
Mixing
n n n n n n n n Nuclear power stations
n n n Paint shops
n n n Paper and cellulose industry
n n n n n n n n n n n n Petrochemical industry
Pharmaceutical industry
n n n n n n n n n n n Pipelines and tank farms
n n n n n n n n n Pressure boosting
n n n n n n n n n n n n n Process engineering
n n n n n n n n Rainwater harvesting
Recirculation
n n n n n n n n n n Refineries
Seawater desalination / reverse osmosis
Sewage treatment plants
Shipbuilding
Sludge disposal
Sludge processing
Snow guns
n n n n n n n n n n n n Spray irrigation
n n n n Sugar industry
n Swimming pools
Thickening
n n n n n n n n n n n Washing plants
n n n n n Water extraction
n n n n n n n n n n n n n n n Water supply
n n n n n n n n n n Water treatment systems

13
Evamatic-Box / Evamatic-Box ICS
Ama-Porter CK Pumping Station
Amarex N CK Pumping Station

Amarex KRT wet/dry-installed


Pumping Station CK 800-Eu

Amarex KRT dry-installed


Pumps

Sewatec / Sewabloc
Ama-Drainer-Box

KWP / KWP-Bloc

Etaprime B / BN
mini-Compacta

LCC-M / LCC-R
Amarex KRT

Etaprime L
Amacan K
Compacta

Amacan P
Amarex N

Amacan S

Amaprop
Amamix

Amaline
Amajet

LSA-S

Mega
Applications

MHD

MDX
WBC

HHD
FGD

LHD
TBC

LCV
LSR

ZW
Air-conditioning systems



Lifting units / collecting tanks

Submersible motor pumps

Submersible pumps in discharge tubes

Mixers / agitators / tank cleaning units

Pumps for solids-laden fluids

Slurry pumps

Self-priming pumps
Aquaculture n n
Boiler circulation
Boiler feed applications
Chemical industry n n n n n
Cleaning of stormwater tanks / storage sewers n n n n n n
Condensate transport
Cooling circuits n
Descaling units n n n n n n n n n n n n n
Dewatering n n n n n n n n n
Disposal n n n n n n n n n n n n
District heating
Dock facilities
Domestic water supply
Drainage n n n n n
Drainage of pits, shafts, etc. n n n
Dredging n n n n n n n n
Fire-fighting systems
Flue gas desulphurization n n n n
Food and beverages industry n n n n n n
Fountains
Heat recovery systems
Heavy oil and coal upgrading n


Homogenization n
Hot water heating systems
Hydraulic solids transport n n n n n n n n n n n n n n
Industrial recirculation systems n n
Irrigation n n n n n n n n
Keeping in suspension n
Lowering ground water levels n n n n
Maintaining ground water levels n n n n
Mining n n n n n n n n n n n n n n
Mixing n
Nuclear power stations
Paint shops n
Paper and cellulose industry n n n n n
Petrochemical industry
Pharmaceutical industry
Pipelines and tank farms
Pressure boosting
Process engineering n
Rainwater harvesting n
Recirculation n
Refineries
Seawater desalination / reverse osmosis n n n n n
Sewage treatment plants n n n n n n n n n n n n n
Shipbuilding
Sludge disposal n n n n n n n n n n n n n
Sludge processing n n n n n n n n n n n n n n n n n
Snow guns n
Spray irrigation
Sugar industry n n n n n n
Swimming pools
Thickening n
Washing plants n n n n
Water extraction n n n n n n
Water supply n n n n n n n
Water treatment systems n n n n n n n n

14
Vitachrom / Vitacast / Vitacast E
Vitaprime / Vitastage / Vitalobe
Multitec / Multitec PumpDrive
Movitec V / LHS / VS / VC

SEZ / SEZT / PHZ / PNZ


UPA 200, 200B, 250C

CHTA / CHTC / CHTD

WKT / WKTA / WKTB


Movitec PumpDrive
S 100D / UPA 100C

HGB / HGC / HGD

RER / RSR / PSR


UPA 300, 350
UPZ, BSX-BSF

YNK / KRHA

Multitec-RO
LUV nuclear
SNW / PNW
LUV / LUVA

RHR / RVR
UPA 150C

HGM-RO
RPH-RO
Omega
RDLO

CHTR

HGM

RHM
RVM
RHD

RUV
SPY
n n n n Air-conditioning systems
Submersible borehole pumps






Pumps for power station conventional islands













High-pressure pumps, fixed / variable speed

Axially split pumps

Hygienic pumps for the food, beverage and pharmaceutical industries

Pumps for power station nuclear islands

Pumps for seawater desalination by reverse osmosis


Aquaculture
n n Boiler circulation
n n n n n n n n n Boiler feed applications
n n n n n n n Chemical industry
Cleaning of stormwater tanks / storage sewers
n n n n n n Condensate transport
n n n n n n n n n n Cooling circuits
n n Descaling units
n n n n Dewatering
Disposal
n n n District heating
n n n Dock facilities
n n Domestic water supply
n Drainage
Drainage of pits, shafts, etc.
Dredging
n n n n n n n n n Fire-fighting systems
Flue gas desulphurization
n n n n n n Food and beverages industry
n n n Fountains
Heat recovery systems
Heavy oil and coal upgrading


Homogenization
n Hot water heating systems
Hydraulic solids transport
n n n Industrial recirculation systems
n n n n n n n n n n n n n Irrigation
Keeping in suspension
n n n n n Lowering ground water levels
n n n n Maintaining ground water levels
n n n n n Mining
Mixing
n n n n n n n n n n n n n n Nuclear power stations
n n Paint shops
n n Paper and cellulose industry
n n n n n Petrochemical industry
n n Pharmaceutical industry
n Pipelines and tank farms
n n n n n Pressure boosting
n Process engineering
n Rainwater harvesting
Recirculation
n n Refineries
n n n n n n n n n n Seawater desalination / reverse osmosis
Sewage treatment plants
n n n n Shipbuilding
Sludge disposal
Sludge processing
n n n n n n Snow guns
n n n n n n n Spray irrigation
n n n Sugar industry
Swimming pools
Thickening
n n n Washing plants
n n n n n n n n n n n Water extraction
n n n n n n n n n n n n n Water supply
n n n n n n n n n Water treatment systems

15
Circulator pumps / hot water service pumps, fixed speed

Rio C Circulator pump with manual speed control

Design: Maintenance-free, glandless wet rotor pump, screw-ended, with three


Rp ________________ 1 -11/4 speed levels.
Q [m3/h] __________ max. 4
Applications: Industrial recirculation systems, air-conditioning systems, cooling
H [m] ___________ max. 5.8
circuits, heat recovery systems and hot water heating systems.
p [bar] ___________ max. 10
T [°C] _ _______ -10 to +110
Data for 50 Hz operation

Switchgears Reference no. 1120.5-10 also available in 60 Hz

Rio Circulator pump with manual speed control

Design: Maintenance-free, glandless wet rotor pump, flanged or screw-ended,


Rp / DN ___ 1-11/4 / 40 - 100 with three speed levels.
Q [m3/h] _________ max. 77
Applications: Industrial recirculation systems, air-conditioning systems, cooling
H [m] ____________ max. 19
circuits, heat recovery systems and hot water heating systems.
p [bar] ___________ max. 10
T [°C] _ _______ -20 to +130
Data for 50 Hz operation

Switchgears Reference no. 1115.51-10 also available in 60 Hz

Rio Z Circulator pump with manual speed control

Design: Maintenance-free, glandless wet rotor pump, flanged or screw-ended, with


Rp / DN ____ 1-11/4 / 32 - 80 three speed levels; in twin pump design (Rio Z) for standby operation with inte-
Q [m3/h] ________ max. 130 grated swing check valve or, on option, peak load operation (parallel operation).
H [m] ____________ max. 18
Applications: Industrial recirculation systems, air-conditioning systems,
p [bar] ___________ max. 10
cooling circuits, heat recovery systems and hot water heating systems.
T [°C] _ _______ -20 to +130
Data for 50 Hz operation

Switchgears Reference no. 1115.51-10 also available in 60 Hz

Riotherm C Hot water service pump

Design: Maintenance-free, glandless wet rotor pump, flanged or screw-ended, with


Rp / DN ___ 1/2 -11/4 / 40 - 50 three speed levels.
Q [m3/h] _________ max. 28
Applications: Air-conditioning systems, cooling circuits and water supply.
H [m] ___________ max. 7.5
p [bar] ___________ max. 10
T [°C] _ _______ -10 to +110
Data for 50 Hz operation

Switchgears Reference no. 1109.5-10 also suitable for 60 Hz operation

Riotherm Hot water service pump

Design: Screw-ended dry rotor pump with mechanical seal and fixed speed.
Rp ________________ 1-11/4
Applications: Hot water supply systems, swimming pools, cooling circuits and
Q [m3/h] _________ max. 10
industrial plants.
H [m] _____________ max. 6
p [bar] ___________ max. 10
T [°C] _ ________ -2 to +110
Data for 50 Hz operation

Switchgears Reference no. 1118.5-10 also available in 60 Hz

16 Automation possible
Circulator pumps, variable speed

Riotronic P High-efficiency circulator pump with continuously variable differential pressure control

Design: Maintenance-free wet rotor pump with integrated frequency inverter for
Rp ________________ 1-11/4 continuously variable differential pressure control.
Q [m3/h] ________ max. 4.2
Applications: Industrial recirculation systems, air-conditioning systems,
H [m] _____________ max. 6
heat recovery systems and hot water heating systems.
p [bar] ___________ max. 10
T [°C] _ ________ -2 to +110
n [min-1] _______ max. 4230

Reference no. 1112.52-10 also suitable for 60 Hz operation

Riotronic Eco High-efficiency circulator pump with continuously variable differential pressure control

Design: Maintenance-free wet rotor pump with integrated frequency inverter for
Rp ________________ 1-11/4 continuously variable differential pressure control.
Q [m3/h] ________ max. 2.5
Applications: Industrial recirculation systems, air-conditioning systems,
H [m] _____________ max. 5
heat recovery systems and hot water heating systems.
p [bar] ___________ max. 10
T [°C] _ ______ +15 to +110
n [min-1] _______ max. 3500

BOA-Systronic Reference no. 1112.51-10

Rio-Eco High-efficiency circulator pump with continuously variable differential pressure control

Design: Maintenance-free wet rotor pump with integrated frequency inverter


Rp / DN ___ 1-11/4 / 32 - 100 for continuously variable differential pressure control and IR interface for remote
Q [m3/h] _________ max. 62 control.
H [m] ____________ max. 13
Applications: Industrial recirculation systems, air-conditioning systems,
p [bar] ___________ max. 10
cooling circuits, heat recovery systems and hot water heating systems.
T [°C] _ _______ -10 to +110
n [min-1] _______ max. 4800

BOA-Systronic Reference no. 1137.5-10 also suitable for 60 Hz operation

Rio-Eco B High-efficiency circulator pump with continuously variable differential pressure control

Design: Maintenance-free wet rotor pump with integrated frequency inverter


Rp / DN ____ 1-11/4 / 40 - 65 for continuously variable differential pressure control and IR interface for remote
Q [m3/h] _________ max. 38 control.
H [m] ____________ max. 10
Applications: Air-conditioning systems, cooling circuits and water supply
p [bar] ___________ max. 10
T [°C] _ ________ -10 to +80
n [min-1] _______ max. 4800

BOA-Systronic Reference no. 1137.5-10 also suitable for 60 Hz operation

Rio-Eco Z High-efficiency circulator pump with continuously variable differential pressure control

Design: Maintenance-free wet rotor pump in twin pump design, with integrated
DN ______________ 32 - 80 frequency inverter for continuously variable differential pressure control and IR
Q [m3/h] ________ max. 108 interface for remote control. Optional pump assignment to main or stand-by duty,
H [m] ____________ max. 13 with automatic changeover in the event of a fault, timer-controlled pump change-
p [bar] ___________ max. 10 over or parallel operation; peak load pump started or stopped as required
T [°C] _ _______ -10 to +110 for optimum efficiency.
n [min-1] _______ max. 4800 Applications: Industrial recirculation systems, air-conditioning systems,
cooling circuits, heat recovery systems and hot water heating systems.

BOA-Systronic Reference no. 1137.51-10 also suitable for 60 Hz operation

Factory-automated Automation possible 17


In-line pumps with fixed / variable speed drive

Etaline In-line pump

Design: Close-coupled, in-line circulator pump with volute casing and


DN ______________ 32 - 200 standardized motor.
Q [m3/h] ________ max. 700
Applications: Hot water heating systems, cooling circuits, air-conditioning, water
H [m] ____________ max. 95
and service water supply systems, industrial recirculation systems.
p [bar] ___________ max. 16
T [°C] _ _______ -30 to +140
Data for 50 Hz operation

PumpMeter · Hyamaster · LevelControl · Switchgears Reference no. 1146.51-10  also available in 60 Hz

Etaline Z In-line twin pump

Design: Close-coupled, in-line twin circulator pump, pump shaft and motor shaft
DN ______________ 32 - 200 are rigidly coupled.
Q [m3/h] _______ max. 1120
Applications: Hot water heating systems, cooling circuits, air-conditioning
H [m] ____________ max. 77
­systems, water and service water supply systems, industrial recirculation systems.
p [bar] ___________ max. 16
T [°C] _ _______ -30 to +140
Data for 50 Hz operation

PumpMeter · Hyamaster · LevelControl · Switchgears Reference no. 1148.5-10  also available in 60 Hz

Etaline PumpDrive In-line pump with motor-mounted variable speed system

Design: Close-coupled in-line circulator pump with motor-mounted variable speed


DN ______________ 32 - 200 system; pump shaft and motor shaft are rigidly coupled.
Q [m3/h] ________ max. 788
Applications: Hot water heating systems, cooling circuits, air-conditioning
H [m] ___________ max. 100
systems, water and service water supply systems, industrial recirculation systems.
p [bar] ___________ max. 16
T [°C] _ _______ -10 to +110
n [min-1] _______ max. 4200

PumpMeter · BOA-Systronic Reference no. 1149.52-10  also suitable for 60 Hz operation

Etaline Z PumpDrive In-line pump with motor-mounted variable speed system

Design: Close-coupled in-line circulator pump, in twin pump design with motor-
DN ______________ 32 - 200 mounted variable speed system; pump shaft and motor shaft are rigidly coupled.
Q [m3/h] ________ max. 990 Double pump control modules (accessories) enable redundant operation of
H [m] ____________ max. 76 Etaline Z without a higher-level controller.
p [bar] ___________ max. 16
Applications: Hot water heating systems, cooling circuits, air-conditioning
T [°C] _ _______ -10 to +110
systems, water and service water supply systems, industrial recirculation systems.
n [[min-1] _______ max. 4200

PumpMeter · BOA-Systronic Reference no. 1154.51-10  also suitable for 60 Hz operation

18 Factory-automated Automation possible


In-line pumps with fixed / variable speed drive

Etaline-R In-line pump

Design: Vertical close-coupled, in-line circulator pump with volute casing and
DN ____________ 150 - 350 standardized motor.
Q [m3/h] _______ max. 1900
Applications: Hot water heating systems, cooling circuits, air-conditioning, water
H [m] ____________ max. 93
and service water supply systems, industrial recirculation systems.
p [bar] ___________ max. 25
T [°C] _ _______ -30 to +140
Data for 50 Hz operation

PumpMeter · PumpDrive · Hyamaster · Switchgears Reference no. 1146.51-10  also available in 60 Hz

Standardized / close-coupled pumps, fixed / variable speed

Etanorm / Etanorm-R Standardized pump

Design: Horizontal, long-coupled, single-stage volute casing pump (pump size 125
DN ______________ 32 - 300 - 500 with two stages) with ratings and main dimensions to EN 733, in back pull-
Q [m3/h] _______ max. 1900 out design, with replaceable shaft sleeves / shaft protecting sleeves and casing
H [m] ___________ max. 102 wear rings. ATEX-compliant version available.
p [bar] ___________ max. 16 Applications: Spray irrigation, irrigation, drainage, district heating, water supply
T [°C] _ ________ max. +140 systems, heating and air-conditioning systems, condensate transport, swimming
Data for 50 Hz operation pools, fire-fighting systems, handling of hot water, cooling water, fire-fighting
water, oil, brine, drinking water, brackish water, service water, etc.

PumpMeter • Hyamaster Reference no. 1211.5-10  also available in 60 Hz

Etanorm PumpDrive Standardized pump with motor-mounted variable speed system

Design: Horizontal, long-coupled, single-stage volute casing pump in back pull-out


DN ______________ 32 - 150 design, with replaceable shaft sleeves / shaft protecting sleeves and casing wear rings
Q [m3/h] ________ max. 800 and motor-mounted variable speed system.
H [m] ___________ max. 102
Applications: Spray irrigation, irrigation, drainage, district heating, water supply
p [bar] ___________ max. 16
systems, heating and air-conditioning systems, condensate transport, swimming
T [°C] _ ________ max. +140
pools, fire-fighting systems, handling of hot water, cooling water, fire-fighting water,
n [min-1] _______ max. 4200
oil, brine, drinking water, brackish water, service water, etc.

PumpMeter Reference no. 1211.5-10 + 4070.5-10

Etabloc Close-coupled pump

Design: Close-coupled, single-stage volute casing pump, ratings to EN 733, with


DN ______________ 25 - 150 replaceable shaft sleeve and casing wear rings. ATEX-compliant version available.
Q [m3/h] ________ max. 660
Applications: Spray irrigation, irrigation, drainage and water supply systems,
H [m] ___________ max. 102
heating and air-conditioning systems, condensate transport, swimming pools,
p [bar] ___________ max. 16
handling of hot water, cooling water, fire-fighting water, seawater, oil, brine,
T [°C] _ ________ max. +140
drinking water, cleaning agents, brackish water, service water, etc.
Data for 50 Hz operation

PumpMeter • Hyamaster Reference no. 1167.5-10  also available in 60 Hz

Factory-automated Automation possible 19


Standardized / close-coupled pumps, fixed / variable speed

Etabloc PumpDrive Close-coupled pump with motor-mounted variable speed system

Design: Close-coupled, single-stage volute casing pump, ratings to EN 733, with


DN ______________ 25 - 150 replaceable shaft sleeve and casing wear rings and motor-mounted variable
Q [m3/h] ________ max. 800 speed system.
H [m] ___________ max. 102
Applications: Spray irrigation, irrigation, drainage and water supply systems, heat-
p [bar] ___________ max. 16
ing and air-conditioning systems, condensate transport, swimming pools, handling
T [°C] _ ________ max. +110
of hot water, cooling water, fire-fighting water, seawater, oil, brine, drinking
n [min-1] _______ max. 4200
water, cleaning agents, brackish water, service water, etc.

PumpMeter Reference no. 1167.5-10 + 4070.5-10

Etachrom BC Close-coupled chrome steel pump

Design: Close-coupled, horizontal, single-stage annular casing pump, with ratings


DN _______________ 25 - 80 and main dimensions to EN 733, with replaceable casing wear rings.
Q [m3/h] ________ max. 260 ATEX-compliant version available.
H [m] ___________ max. 108
Applications: Spray irrigation, irrigation, drainage and water supply systems,
p [bar] ___________ max. 12
heating and air-conditioning systems, fire-fighting systems, condensate transport,
T [°C] _ ________ max. +110
swimming pools, handling of hot water, cooling water, fire-fighting water, oil,
Data for 50 Hz operation
drinking water, cleaning agents, service water.

PumpMeter · Hyamaster Reference no. 1213.5-10  also available in 60 Hz

Etachrom BC PumpDrive Close-coupled chrome steel pump with motor-mounted variable speed system

Design: Close-coupled, horizontal, single-stage annular casing pump, with ratings


DN _______________ 25 - 80 and main dimensions to EN 733, with replaceable casing wear rings and motor-
Q [m3/h] ________ max. 260 mounted variable speed system.
H [m] ___________ max. 106
Applications: Spray irrigation, irrigation, drainage and water supply systems,
p [bar] ___________ max. 12
heating and air-conditioning systems, fire-fighting systems, condensate transport,
T [°C] _ ________ max. +110
swimming pools, handling of hot water, cooling water, fire-fighting water, oil,
n [min-1] _______ max. 3500
drinking water, cleaning agents, service water.

PumpMeter Reference no. 1213.5-10 + 4070.5-10

Etachrom NC Standardized chrome steel pump

Design: Horizontal, single-stage annular casing pump, with ratings and main
DN _______________ 25 - 80 dimensions to EN 733, with replaceable casing wear rings. ATEX-compliant version
Q [m3/h] ________ max. 260 available.
H [m] ___________ max. 106
Applications: Water supply, spray irrigation, irrigation and drainage systems, hea-
p [bar] ___________ max. 12
ting and air-conditioning systems, fire-fighting systems, handling of drinking water,
T [°C] _ ________ max. +110
service water, hot water, cooling water, swimming pool water, fire-fighting water,
Data for 50 Hz operation
condensate, oil and cleaning agents.

PumpMeter · Hyamaster Reference no. 1212.5-10  also available in 60 Hz

Etachrom NC PumpDrive Standardized chrome steel pump with motor-mounted variable speed system

Design: Horizontal, single-stage annular casing pump, with ratings and main
DN _______________ 25 - 80 dimensions to EN 733, with replaceable casing wear rings and motor-mounted
Q [m3/h] ________ max. 260 ­variable speed system.
H [m] ___________ max. 106
Applications: Water supply, spray irrigation, irrigation and drainage systems, hea-
p [bar] ___________ max. 12
ting and air-conditioning systems, fire-fighting systems, handling of drinking water,
T [°C] _ ________ max. +110
service water, hot water, cooling water, swimming pool water, fire-fighting water,
n [min-1] _______ max. 3500
condensate, oil and cleaning agents.

PumpMeter Reference no. 1212.5-10 + 4070.5-10

20 Factory-automated Automation possible


Standardized / close-coupled pumps, fixed / variable speed

Etanorm GPV / CPV Vertical low-pressure pump

Design: Single-stage volute casing pump, ratings to EN 733, for vertical installa-
DN ______________ 32 - 150 tion in closed tanks under atmospheric pressure. Up to an immersion depth of
Q [m3/h] ________ max. 660 2000 mm.
H [m] ___________ max. 102
Applications: Handling of neutral degreasing and phosphatizing solutions, wash
p [bar] ___________ max. 16
water with degreasing agents, dipping paints, etc.
T [°C] _ _________ max. +95
Data for 50 Hz operation

Reference no. 1214.5-10  also available in 60 Hz

Hot water pumps

HPK-L Hot water / thermal oil recirculation pump without external cooling

Design: Horizontal, radially split volute casing pump in back pull-out design to
DN ______________ 25 - 250 EN 22 858 / ISO 2858 / ISO 5199, single-stage, single-entry, with radial impeller.
Q [m3/h] _______ max. 1330 Equipped with heat barrier, seal chamber air-cooled by integrated fan impeller, no
H [m] ___________ max. 155 external cooling. ATEX-compliant version available.
p [bar] ___________ max. 40
Applications: Handling of hot water and thermal oil in piping or tank systems,
T [°C] _ _ max. +240 / +350
particularly in medium­-sized and large hot water heating systems, forced
Data for 50 Hz operation
circulation boilers, district heating systems, etc.

PumpDrive • Hyamaster Reference no. 1136.5-10  also available in 60 Hz

HPK Hot water recirculation pump

Design: Horizontal, radially split volute casing pump in back pull-out design to
DN _____________ 150 - 400 EN 22 858 / ISO 2858 / ISO 5199, single-stage, single-entry, with radial impeller.
Q [m3/h] _______ max. 4150 TÜV certification to TRD on option. ATEX-compliant version available.
H [m] ___________ max. 185
Applications: Handling of hot water and thermal oil in piping or tank systems,
p [bar] ___________ max. 40
particularly in medium-sized and large hot water heating systems, forced
T [°C] _ ________ max. +400
circulation boilers, district heating systems, etc.
Data for 50 Hz operation

PumpDrive • Hyamaster Reference no. 1121.51-10  also available in 60 Hz

HPH Hot water recirculation pump

Design: Horizontal, radially split volute casing pump in back pull-out design,
DN ______________ 40 - 350 single-stage, single-entry, with centreline pump feet and radial impeller.
Q [m3/h] _______ max. 2350 TÜV certification to TRD on option. ATEX-compliant version available.
H [m] ___________ max. 225
Applications: Handling of hot water in high-pressure hot water generation plants
p [bar] __________ max. 110
and for use as boiler feed and recirculation pump.
T [°C] _ ________ max. +320
Data for 50 Hz operation

Hyamaster Reference no. 1122.5-10  also available in 60 Hz

Automation possible 21
Hot water / thermal oil pumps

Etanorm SYT / RSY Hot water / thermal oil pump

Design: Horizontal, long-coupled volute casing pump in back pull-out design with
DN ______________ 32 - 300 ratings and main dimensions to EN 733, single-stage, with replaceable casing wear
Q [m3/h] _______ max. 1900 rings. ATEX-compliant version available.
H [m] ___________ max. 102
Applications: Heat transfer systems (DIN 4754, VDI 3033) or hot water recircula-
p [bar] ___________ max. 16
tion (DIN 4752).
T [°C] _ ________ max. +350
Data for 50 Hz operation

Hyamaster Reference no. 1220.5-10  also available in 60 Hz

Etabloc SYT / Etaline SYT Hot water / thermal oil pump

Design: Horizontal, single-stage volute casing pump in back pull-out design with
DN ______________ 32 - 100 ratings and main dimensions to EN 733, or in in-line design, with replaceable
Q [m3/h] ________ max. 280 ­casing wear rings.
H [m] ____________ max. 67
Applications: Heat transfer systems (DIN 4754) or hot water recirculation.
p [bar] ___________ max. 16
T [°C] _ ________ max. +350
Data for 50 Hz operation

Hyamaster Reference no. 1170.5-10  also available in 60 Hz

Thermal oil pumps with magnetic drive / canned motor

Etamagno SY / SYI / Bloc SY Thermal oil pump

Design: Horizontal, seal-less, single-stage volute casing pump with magnetic drive,
DN____________ 32 - 150 ratings and main dimensions to EN 733, with replaceable casing wear rings.
Q [m3/h]________ max. 660
Applications: Handling of thermal oil in heat transfer systems to DIN 4754.
H [m]__________ max. 102
p [bar]_ _________ max. 16
T [°C]________ max. +350
Data for 50 Hz operation

Hyamaster Reference no. 1218.5-10  also available in 60 Hz

(Only available in Europe, Russia, Middle East and Africa)

HX (Nikkiso-KSB) Thermal oil pump with explosion protection

Design: Horizontal, seal-less, single-stage pump with fully enclosed canned motor,
DN _ __________ 32 - 100 uncooled. ATEX-compliant version available.
Q [m3/h] _ ______ max. 200
Applications: Handling of thermal oils and other hot fluids in heat transfer
H [m] __________ max. 100
systems to DIN 4754.
p [bar] __________ max. 40
T [°C] _ ______ max. +350
Data for 50 Hz operation

 also available in 60 Hz

22 Automation possible
Thermal oil pumps with magnetic drive / canned motor

(Only available in Europe, Russia, Middle East and Africa)

HY (Nikkiso-KSB) Thermal oil pump with explosion protection

Design: Horizontal, seal-less, single-stage pump with fully enclosed canned motor,
DN_____________ 32 - 80 uncooled, coolable or heatable. ATEX-compliant version available.
Q [m3/h] _ ______ max. 150
Applications: Handling of thermal oils and other hot fluids in heat transfer
H [m] __________ max. 100
systems to DIN 4754.
p [bar] __________ max. 40
T [°C]________ max. +250
Data for 50 Hz operation

 also available in 60 Hz

Standardized chemical pumps

CPKN Standardized chemical pump with reinforced bearing bracket

Design: Horizontal, radially split volute casing pump in back pull-out design to
DN ______________ 25 - 400 EN 22 858 / ISO 2858 / ISO 5199, single-stage, single-entry, with radial impeller.
Q [m3/h] _______ max. 4150 Also available as variant with “wet” shaft, conical seal chamber, heatable volute
H [m] ___________ max. 185 casing (CPKN-CHs) and/or semi-open impeller (CPKNO). ATEX-compliant version
p [bar] ___________ max. 25 available.
T [°C] _ ________ max. +400 Applications: Handling of aggressive liquids in the chemical and petrochemical
Data for 50 Hz operation
industries as well as in refinery and fire-fighting systems, handling of brine.

Hyamaster Reference no. 2730.5-10  also available in 60 Hz

CPKN PumpDrive Standardized chemical pump with reinforced bearing bracket and motor-mounted variable speed system

Design: Horizontal, radially split volute casing pump in back pull-out design to
DN ______________ 25 - 300 EN 22 858 / ISO 2858 / ISO 5199, single-stage, single-entry, with radial impeller.
Q [m3/h] _______ max. 1050 Also available as variant with “wet” shaft, conical seal chamber and/or semi-open
H [m] ___________ max. 220 impeller (CPKNO) with motor-mounted variable speed system.
p [bar] ___________ max. 25
Applications: Handling of aggressive liquids in the chemical and petrochemical
T [°C] _ ________ max. +110
industries as well as in refinery and fire-fighting systems, handling of brine.
n [min-1] _______ max. 3600

Reference no. 2730.5-10 + 4070.5-10

CPK-D Standardized chemical pump with hydrodynamic shaft seal

Design: Horizontal, radially split volute casing pump in back pull-out design to
DN ______________ 32 - 250 ISO 2858, single-stage, single-entry, with radial impeller and zero-leakage
Q [m3/h] _______ max. 1100 hydrodynamic shaft seal.
H [m] ___________ max. 128
Applications: Handling of liquids in the chemical and petrochemical industry,
p [bar] ___________ max. 25
in refineries and paint shops.
T [°C] _ ________ max. +150
Data for 50 Hz operation

Hyamaster Reference no. 2726.1-10  also available in 60 Hz

Factory-automated Automation possible 23


Seal-less pumps

Magnochem Standardized chemical pump with mag-drive

Design: Horizontal, seal-less, mag-drive volute casing pump in back pull-out


DN _____________ 25 - 250 design to ISO 2858 / EN 22 858 / ISO 5199, single-stage, single-entry, with radial
Q [m3/h] _______ max. 1250 impeller. ATEX-compliant version available.
H [m] ___________ max. 153
Applications: Handling of aggressive, toxic, explosive, valuable, flammable,
p [bar] ___________ max. 25
malodorous or harmful liquids in the chemical, petrochemical and general industry.
T [°C] _ ________ max. +300
Data for 50 Hz operation

Hyamaster Reference no. 2739.5-10  also available in 60 Hz

Magnochem - Bloc Close-coupled chemical pump with mag-drive

Design: Horizontal, seal-less, close-coupled, mag-drive volute casing pump to


DN ______________ 25 - 125 ISO 2858 / EN 22 858 / ISO 5199, single-stage, single-entry, with radial impeller.
Q [m3/h] ________ max. 240 ATEX-compliant version available.
H [m] ___________ max. 153
Applications: Handling of aggressive, toxic, explosive, valuable, flammable,
p [bar] ___________ max. 25
mal odorous or harmful liquids in the chemical, petrochemical and general industry.
T [°C] _ ________ max. +250
Data for 50 Hz operation

Hyamaster Reference no. 2749.5-10  also available in 60 Hz

Etaseco / Etaseco-I Water motor pumps with canned motor

Design: Horizontal / vertical, seal-less volute casing pump in back pull-out design
DN ______________ 32 - 100 with fully enclosed canned motor, low noise emission, with radial impeller, single-
Q [m3/h] ________ max. 250 stage, single-entry, pump casing connecting dimensions to EN 733.
H [m] ___________ max. 100
Applications: Handling of aggressive, flammable, toxic, volatile, or valuable
p [bar] ___________ max. 16
liquids in the chemical and petrochemical industry, in environmental engineering
T [°C] _ ________ max. +140
and the general industry.
Data for 50 Hz operation

PumpMeter • Hyamaster • PumpDrive Reference no. 2935.5-10  also available in 60 Hz

Etaseco RVP Cooling circuit pump with canned motor

Design: Horizontal/vertical seal-less volute casing pump in back pull-out design


DN ___________________ 32 with fully enclosed canned motor, low noise emission, with radial impeller, single-
Q [m3/h] _________ max. 20 stage, single-entry.
H [m] ____________ max. 25
Applications: Pump for handling toxic, volatile or valuable fluids in environmen-
p [bar] ___________ max. 10
tal and industrial engineering and for use as a coolant pump in cooling systems.
T [°C] _ _________ max. +85
Transport vehicles, environmental and industrial engineering; applications where
low noise emission, smooth running or long service intervals are required.

PumpMeter • PumpDrive Reference no. 2935.17-10  also available in 60 Hz

Secochem Ex Standardized chemical pump with canned motor and explosion protection

Design: Horizontal, seal-less volute casing pump in back pull-out design with fully
DN ______________ 25 - 100 enclosed canned motor, low noise emission, with radial impeller, single-stage,
Q [m3/h] ________ max. 300 single­-entry, casing connecting dimensions to EN 22 858 / ISO 2858.
H [m] ___________ max. 150 Design to ATEX.
p [bar] ___________ max. 25
Applications: Handling of aggressive, flammable, explosive, toxic, volatile or
T [°C] _ ________ max. +130
valuable liquids in the chemical and petrochemical industry, in environmental
Data for 50 Hz operation
engineering and the general industry.

Hyamaster Reference no. 2939.5-10  also available in 60 Hz

24 Automation possible
Seal-less pumps

Secochem Ex K Standardized chemical pump with canned motor and explosion protection

Design: Horizontal, seal-less volute casing pump in back pull-out design with fully
DN ______________ 25 - 100 enclosed canned motor, low noise emission, with radial impeller, single-stage,
Q [m3/h] ________ max. 300 single­-entry, pump casing connecting dimensions to EN 22 858 / ISO 2858, with
H [m] ___________ max. 150 external cooler. Design to ATEX.
p [bar] ___________ max. 25
Applications: Handling of aggressive, flammable, explosive, toxic, volatile or
T [°C] _ ________ max. +400
valuable liquids in the chemical and petrochemical industry, in environmental
Data for 50 Hz operation
engineering and the general industry.

Hyamaster Reference no. 2939.51-10  also available in 60 Hz

(Only available in Europe, Russia, Middle East and Africa)

HN / BN / TN (Nikkiso-KSB) Chemical canned motor pump with explosion protection

Design: Horizontal (HN) or vertical (BN / TN), seal-less, single-stage pump with
DN ______________ 32 - 300 fully enclosed canned motor, uncooled, coolable or heatable. ATEX-compliant
Q [m3/h] ________ max. 800 version available.
H [m] ___________ max. 200
Applications: Handling of aggressive, flammable, explosive, toxic, volatile or
p [bar] ___________ max. 40
valuable liquids in the chemical and petrochemical industry.
T [°C] _ ________ max. +180
Data for 50 Hz operation

 also available in 60 Hz

(Only available in Europe, Russia, Middle East and Africa)

HT / BT / TT (Nikkiso-KSB) Chemical canned motor pump with explosion-protection for special applications

Design: Horizontal (HT) or vertical (BT /TT), seal-less, single-stage pump with fully
DN ______________ 32 - 300 enclosed canned motor, coolable. ATEX-compliant version available.
Q [m3/h] ________ max. 800
Applications: Handling of aggressive, solids-containing, polymerizing, flammable,
H [m] ___________ max. 200
explosive, toxic, volatile or valuable liquids as well as thermal oils in the chemical
p [bar] ___________ max. 40
and petrochemical industry.
T [°C] _ ________ max. +400
Data for 50 Hz operation

 also available in 60 Hz

(Only available in Europe, Russia, Middle East and Africa)

HK (Nikkiso-KSB) Two-stage canned motor pump with explosion protection

Design: Horizontal, seal-less pump with fully enclosed canned motor, two-stage
DN _______________ 25 - 40 design in tandem arrangement. ATEX-compliant version available.
Q [m3/h] _________ max. 10
Applications: Handling of aggressive, flammable, explosive, toxic, volatile or
H [m] ___________ max. 300
valuable liquids in the chemical and petrochemical industry. For small flow rates,
p [bar] ___________ max. 40
high discharge heads and low NPSHR.
T [°C] _ ________ max. +150
n [min-1] _______ max. 8400
Data for n = 8400 min-1

 high speed, up to 130 Hz

(Only available in Europe, Russia, Middle East and Africa)

VN (Nikkiso-KSB) Multistage canned motor pump with explosion protection

Design: Horizontal, seal-less pump with fully enclosed canned motor, multistage.
DN ______________ 40 - 100 ATEX-compliant version available.
Q [m3/h] ________ max. 140
Applications: Handling of aggressive, flammable, explosive, toxic, volatile or
H [m] ___________ max. 450
valuable liquids in the chemical and petrochemical industry. For high discharge
p [bar] ___________ max. 40
heads.
T [°C] _ ________ max. +180
Data for 50 Hz operation

 also available in 60 Hz

Automation possible 25
Seal-less pumps

(Only available in Europe, Russia, Middle East and Africa)

DN (Nikkiso-KSB) Self-priming canned motor pump with explosion protection

Design: Horizontal, seal-less pump with fully enclosed canned motor, single stage,
DN _______________ 32 - 50 self-priming. ATEX-compliant version available.
Q [m3/h] _________ max. 40
Applications: Handling of aggressive, flammable, explosive, toxic, volatile or
H [m] ____________ max. 60
valuable liquids in the chemical and petrochemical industry. Self-priming pump for
p [bar] ___________ max. 40
draining of tanks and unloading of tanks and tank trucks.
T [°C] _ ________ max. +180
Data for 50 Hz operation

 also available in 60 Hz

Process pumps

RPH Process pump

Design: Horizontal, radially split volute casing pump in back pull-out design to
DN ______________ 25 - 400 API 610, 10th edition, or ISO 13709 (heavy duty), with radial impeller, single-stage,
Q [m3/h] _______ max. 4150 single-entry, centreline pump feet; with inducer, if required. ATEX-compliant
H [m] ___________ max. 270 version available.
p [bar] ___________ max. 51
Applications: Refineries, petrochemical and chemical industry, power stations.
T [°C] _ ________ max. +450
Data for 50 Hz operation

Hyamaster Reference no. 1312.5-10 / 1316.51 -10 also available in 60 Hz

CTN Chemical vertical shaft submersible pump

Design: Radially split, vertical shaft submersible pump with double volute for wet
DN ______________ 25 - 250 and dry installation, single- or double-stage, single-entry, with radial impeller;
Q [m3/h] ________ max. 800 heatable model available. ATEX-compliant version available.
H [m] ____________ max. 93
Applications: Handling of chemically aggressive liquids, also slightly contaminated
p [bar] ___________ max. 16
or with a low solids content, in the chemical and petrochemical industry.
T [°C] _ ________ max. +300
Data for 50 Hz operation

Reference no. 2711.5-10  also available in 60 Hz

(Only available in Europe, Russia, Middle East and Africa)

API series (Nikkiso-KSB) Refinery pump

Design: Horizontal or vertical canned motor pump to API 685, single-stage, with
DN _______________ 1½ - 6 centreline pump feet; also available with inducer.
Q [m3/h] ________ max. 360
Applications: HNP: for clean liquids; HTP: for hot fluids; HSP / HMP: for contam-
H [m] ___________ max. 220
inated or polymerising fluids; HRP: for fluids with a steep vapour pressure curve
p [bar] ___________ max. 40
such as liquefied gases.
T [°C] _ ________ max. +450
Data for 50 Hz operation

 also available in 60 Hz

26 Automation possible
Centrifugal pump for minimal volume flows

Microchem Centrifugal pump for minimal volume flows

Design: System consisting of a variable-speed single-stage centrifugal pump with


Q [ml/min] ______ 0 to 5000 directly flanged motor and control unit.
H [m] ___________ max. 200
Applications: Continuous volume flow control for handling aggressive organic and
p [bar] ___________ max. 25
inorganic fluids in chemical and pharmaceutical processes. The pump is suitable
T [°C] _ _______ -10 to +100
for use in laboratories, pilot plants and in production processes, particularly in
industrial process engineering, continuous processes, micro-process engineering,
miniplants, dosing, coating, spray-drying and injection applications.

A Reference no. 2600.5-10

Rainwater harvesting systems

Hya-Rain / Hya-Rain N Rainwater harvesting system with one pump

Design: Ready-to-connect package rainwater harvesting system. Automatic mains


Rp ____________________ 1 water back-up if the rain water storage tank is empty, with integrated dry-running
Q [m3/h] __________ max. 4 protection. Automated with automatic control unit.
H [m] ____________ max. 43
Applications: Rainwater and service water utilization, irrigation and spray
p [bar] ____________ max. 6
irrigation systems.
T [°C] _ _________ max. +35
Data for 50 Hz operation

A Reference no. 5602.51-10

Hya-Rain Eco Rainwater harvesting system with one pump

Design: Ready-to-connect package rainwater harvesting system. Automatic mains


Rp ____________________ 1 water back-up function if the rain water storage tank is empty, with integrated dry-
Q [m3/h] __________ max. 4 running protection.
H [m] ____________ max. 43
Applications: Rainwater and service water utilization, irrigation and spray
p [bar] ____________ max. 6
irrigation systems.
T [°C] _ _________ max. +35
Data for 50 Hz operation

A Reference no. 5605.5-10

Factory-automated 27
Domestic water supply systems
with automatic control unit / swimming pools

Multi Eco Multistage, self-priming centrifugal pump

Design: Multistage, self-priming centrifugal pump in close-coupled design.


Rp ________________ 1-1¼
Applications: Single- or two-family houses, agricultural facilities, spray irrigation
Q [m3/h] __________ max. 8
and irrigation systems, washing plants, water supply and rainwater harvesting
H [m] ____________ max. 54
systems.
p [bar] ___________ max. 10
T [°C] _ _________ max. +50
n [min-1] _______ max. 2800

Controlmatic • Cervomatic Reference no. 5180.5-10

Multi Eco-Pro Multistage, self-priming centrifugal pump with automatic control unit

Design: Multistage, self-priming centrifugal pump in close-coupled design, with


Rp ________________ 1-1¼ power cable, plug and Controlmatic E automatic control unit switching the pump
Q [m3/h] __________ max. 8 on and off as consumers are opened / closed and protecting the pump against dry
H [m] ____________ max. 54 running. Automated with automatic control unit.
p [bar] ___________ max. 10
Applications: Single- or two-family houses, agricultural facilities, spray irrigation
T [°C] _ _________ max. +50
and irrigation systems, washing plants, water supply and rainwater harvesting
n [min-1] _______ max. 2800
systems.

Reference no. 5182.5-10

Multi Eco-Top Domestic water supply system

Design: Multistage, self-priming centrifugal pump in close-coupled design incl.


Rp ________________ 1-1¼ accumulator with replaceable membrane in drinking water quality, total volume
Q [m3/h] __________ max. 8 20 or 50 l, pressure switch for automatic pump operation and 1.5 m power cable.
H [m] ____________ max. 54 Automated with automatic control unit.
p [bar] ____________ max. 7
Applications: Single- or two-family houses, agricultural facilities, spray irrigation
T [°C] _ _________ max. +50
and irrigation systems, washing plants, water supply and rainwater harvesting
n [min-1] _______ max. 2800
systems.

A Reference no. 5181.5-10

Movitec VME High-pressure in-line pump in close-coupled design

Design: Multistage, vertical (horizontal installation upon request) high-pressure


Rp __________________ 1½
centrifugal pump, with suction and discharge nozzles of identical nominal
Q [m3/h] __________ max. 9
diameters­ arranged opposite to each other (in-line design).
H [m] ____________ max. 48
p [bar] ___________ max. 16 Applications: Single- or two-family houses, agricultural facilities, spray irrigation
T [°C] _ _________ max. +60 and irrigation systems, washing plants, water supply and rainwater harvesting
n [min-1] _______ max. 2900 systems, pressure boosting, hot water and cooling water recirculation, fire-fighting
Data for 50 Hz operation systems.

A PumpMeter • Hyamaster Reference no. 1798.5-10  also available in 60 Hz

Ixo Submersible motor pump

Design: Fully or partly submerged, multistage, close-coupled centrifugal pump


Rp __________________ 1¼ (min. immersion depth 0.1 m), low-level inlet, suction strainer with a max. mesh
Q [m3/h] __________ max. 8 size of 2.5 mm.
H [m] ____________ max. 65
Applications: Water supply, spray irrigation and irrigation systems, washing
T [°C] _ _________ max. +35
plants, rainwater harvesting systems, water extraction from wells, tanks and
n [min-1] _______ max. 2900
cisterns.

Switchgears • Cervomatic Reference no. 2146.5-10

28 Factory-automated Automation possible


Domestic water supply systems
with automatic control unit / swimming pools

Filtra N Recirculating pump for swimming pool filtering systems

Design: Self-priming, single-stage, close-coupled centrifugal pump.


Rp ____________________ 2
Applications: Handling of clean or slightly contaminated water, swimming pool
Q [m3/h] _________ max. 36
water with a chlorine content of up to 0.3 %, ozonized swimming pool water with
H [m] ____________ max. 21
a salt content of up to 7 ‰.
p [bar] __________ max. 2.5
T [°C] _ _________ max. +35
n [min-1] _______ max. 2800

A Reference no. 2127.5-10

Pressure booster systems

Hya-Solo E Pressure booster system, 1 pump

Design: Fully automatic package single-pump system with 8 l membrane-type


Rp __________________ 1¼ accumulator, pressure-controlled starting and flow-controlled stopping. Automated
Q [m3/h] __________ max. 6 with automatic control unit.
H [m] ____________ max. 50
Applications: Water supply systems for residential and office buildings, irrigation/
p [bar] ___________ max. 10
spray irrigation and rainwater harvesting systems, service water supply systems in
T [°C] _ _________ max. +60
trade and industry.
Data for 50 Hz operation

A Reference no. 1951.5-10

Hya-Solo D Pressure booster system, 1 pump

Design: Fully automatic package single-pump system with 8 l membrane-type


Rp / DN _________ 1¼ / 100 accumulator, pressure-controlled starting and stopping.
Q [m3/h] ________ max. 110
Applications: For industrial plants, water supply systems for residential and office
H [m] ___________ max. 150
buildings, ­irrigation/spray irrigation and rainwater harvesting systems, service
p [bar] ___________ max. 16
water supply systems in trade and industry.
T [°C] _ _________ max. +70
Data for 50 Hz operation

A Reference no. 1951.5-10

Hya-Solo DV Pressure booster system, 1 pump

Design: Fully automatic variable-speed package single-pump system with


Rp / DN _________ 1¼ / 100 PumpDrive, pressure-controlled starting and flow-controlled stopping. Automated
Q [m3/h] ________ max. 110 with PumpDrive.
H [m] ___________ max. 150
Applications: For industrial plants, water supply systems for residential and office
p [bar] ___________ max. 16
buildings, ­irrigation/spray irrigation and rainwater harvesting systems, service
T [°C] _ _________ max. +70
water supply systems in trade and industry.
Data for 2900 min-1

A Reference no. 1951.5-10

Factory-automated 29
Pressure booster systems

Hya-Eco K Pressure booster system, 2 to 3 pumps

Design: Fully automatic package pressure booster system, with 2 to 3 vertical


Rp / DN ____________ 2 / 80 high-pressure pumps, fully electronic control to ensure the required supply pressure,
Q [m3/h] _________ max. 70 standard version with volt-free changeover contact for general fault indication and
H [m] ___________ max. 100 live-zero monitoring of the connected sensors, configuration and functions to
p [bar] ___________ max. 10 DIN 1988, Part 5. Automated with BoosterControl.
T [°C] _ _________ max. +70
Applications: Residential buildings, hospitals, office buildings, hotels, department
Data for 50 Hz operation
stores, industry, etc.

A Reference no. 1967.5-10

Hya-Eco VP Pressure booster system with continuously variable speed control of each pump

Design: Fully automatic package pressure booster system, with 2 to 3 vertical high-
Rp / DN ____________ 2 / 80 pressure pumps and continuously variable speed adjustment of each pump for fully
Q [m3/h] _________ max. 70 electronic control of the required supply pressure, with two standard volt-free
H [m] ___________ max. 120 changeover contacts for fault indication. Configuration and function to DIN 1988,
p [bar] ___________ max. 12 Part 5. Automated with BoosterControl.
T [°C] _ _________ max. +70
Applications: Residential buildings, hospitals, office buildings, hotels, department
Data for 3500 min-1
stores, industry, and other applications.

A Reference no. 1967.52-10

Hyamat K Pressure booster system, 2 to 6 pumps

Design: Fully automatic package pressure booster system, with 2 to 6 vertical


Rp / DN _________ 1½ / 250 high-pressure pumps, fully electronic control to ensure the required supply pres-
Q [m3/h] ________ max. 660 sure, with volt-free changeover contact for general fault indication and live-zero
H [m] ___________ max. 160 monitoring of the connected sensors, configuration and functions to DIN 1988,
p [bar] ___________ max. 16 Part 5. Automated with BoosterControl.
T [°C] _ _________ max. +70
Applications: Residential buildings, hospitals, office buildings, hotels, department
Data for 50 Hz operation
stores, industry, etc.

Reference no. 1952.5-10

Hyamat V Pressure booster system with continuously variable speed adjustment of one pump

Design: Fully automatic package pressure booster system, with 2 to 6 vertical


Rp / DN _________ 1½ / 250 high-pressure pumps and continuously variable speed adjustment of one pump for
Q [m3/h] ________ max. 660 fully electronic control of the required supply pressure. Configuration and functions
H [m] ___________ max. 160 to DIN 1988, Part 5. Automated with BoosterControl.
p [bar] ___________ max. 16
Applications: Pressure boosting in residential buildings, hospitals, office buildings,
T [°C] _ _________ max. +70
hotels, department stores, industry, etc.
Data for 2900 min-1

Reference no. 1953.51-10

Hyamat VP Pressure booster system with continuously variable speed control of each pump

Design: Fully automatic package pressure booster system, with 2 to 6 vertical


Rp / DN _________ 1½ / 250 high-pressure pumps and continuously variable speed control of each pump by
Q [m3/h] ________ max. 660 PumpDrive speed control system. For fully electronic control of the required sup-
H [m] ___________ max. 160 ply pressure. Configuration and functions to DIN 1988, Part 5. Automated with
p [bar] ___________ max. 16 BoosterControl and PumpDrive.
T [°C] _ _________ max. +70
Applications: Pressure boosting in residential buildings, hospitals, office buildings,
Data for 2900 min-1
hotels, department stores, industry, etc.

Reference no. 1953.52-10

30 Factory-automated
Pressure booster systems

Hyamat IK, IV, IVP Pressure booster system for industrial applications

Design: Fully automatic package pressure booster system, with 2 to 4 vertical


DN _____________ 100 - 200 high-pressure pumps and fully electronic control to ensure the required supply
Q [m3/h] ________ max. 640 pressure, configuration and functions to DIN 1988, Part 5. Automated with PLC.
H [m] ___________ max. 160
Applications: Handling of service water and cooling water not chemically or
p [bar] ___________ max. 16
mechanically aggressive to the pump materials in industry, etc.
T [°C] _ _________ max. +70
Data for 50 Hz operation

A Reference no. 1950.5-10

Drainage pumps / waste water pumps

Ama-Drainer N 301, 302, 303, 358 Submersible motor pump

Design: Vertical, fully floodable submersible motor pump in close-coupled design,


Rp ______________ 1¼ - 1½ IP 68, single-stage, with or without level control, max. immersion depth 2 m.
Q [m3/h] _________ max. 17
Applications: Automatic drainage of pits, shafts, yards and cellars subject to a
H [m] ____________ max. 12
flooding risk, lowering of surface water levels, dewatering, drainage of under-
T [°C] _ _________ max. +35
ground passages, water extraction from rivers and reservoirs.
Data for 50 Hz operation

Switchgears • LevelControl Reference no. 2331.51-10 / 2331.52-10

Ama-Drainer 400/10 400/35 500/10/11 Submersible motor pump

Design: Vertical, fully floodable submersible motor pump in close-coupled design,


Rp _______________ 1½ - 2 IP 68, single-stage, with or without level control, max. immersion depth 10 m.
Q [m3/h] _________ max. 50
Applications: Automatic drainage of pits, shafts, yards and cellars subject to a
H [m] ____________ max. 24
flooding risk, lowering of surface water levels, dewatering, drainage of under-
T [°C] _ _________ max. +40
ground passages, water extraction from rivers and reservoirs, disposal of highly
Data for 50 Hz operation
contaminated, fibre-containing water.

Switchgears • LevelControl Reference no. 2331.53-10

Ama-Drainer 80, 100 Submersible motor pump

Design: Vertical, fully floodable submersible motor pump in close-coupled design,


Rp / DN _ _______ 2½ / 100 IP 68, single-stage, with or without level control, max. immersion depth 10 m.
Q [m3/h] ________ max. 130
Applications: Automatic drainage of pits, shafts, yards and cellars subject to a
H [m] ____________ max. 26
flooding risk, lowering of surface water levels, dewatering, drainage of under-
T [°C] _ _________ max. +50
ground passages, water extraction from rivers and reservoirs.
Data for 50 Hz operation

Switchgears • LevelControl Reference no. 2331.54-10

Factory-automated Automation possible 31


Drainage pumps / waste water pumps

Ama-Porter F / S / ICS Submersible motor pump

Design: Vertical, fully floodable submersible waste water pump in close-coupled


DN _______________ 50 - 65 design (cast iron variant), single-stage, without explosion protection.
Q [m3/h] _________ max. 40
Applications: Handling of all types of waste water.
H [m] ____________ max. 21
T [°C] _ _________ max. +40
Data for 50 Hz operation

(ICS) Switchgears • LevelControl (Ama-Porter F/S) Reference no. 2541.51-10 / 2539.51-10 / 2539.52-10 / 2539.53-10

Rotex Waste water pump

Design: Vertical, single-stage centrifugal pump with discharge to the top and par-
Rp _______________ 1¼ - 2 allel with the pump shaft, pump foot designed as suction strainer. Pump and motor
Q [m3/h] _________ max. 24 are rigidly connected by a support pipe, ready to be plugged in, with 1.5 m power
H [m] ____________ max. 14 cable and level switch.
T [°C] _ _________ max. +90 Applications: Automatic disposal of waste water from buildings, pits and tanks,
Data for 50 Hz operation
lowering of surface water levels and drainage.

Reference no. 2322.5-10

MK / MKY Waste water, condensate and heat transfer liquid pump

Design: Vertical submersible pump with three-channel impeller, volute casing


Rp / DN ____________ 2 / 50 designed as suction strainer.
Q [m3/h] _________ max. 36
Applications: Handling of condensate and heat transfer liquids below the boiling
H [m] ____________ max. 19
point, condensate return systems, primary and secondary heating circuits, direct
T [°C] _ ________ max. +200
installation in heating tanks or heat exchangers in the secondary circuits of heat
Data for 50 Hz operation
transfer systems (MKY).

Switchgears • LevelControl Reference no. 2324.5-10

32 Factory-automated Automation possible


Lifting units / collecting tanks

arch 2011 –
r sale until M
Ama-Drainer-Box Released fo Ama Draine
r Box. Automatic waste water lifting unit
eded by new
to be supers

DN _______________ 40 - 50 Design: Stable above-floor or impact-resistant underfloor plastic collecting tank


Q [m3/h] _________ max. 35 with floor drain and odour trap, both variants with Ama-Drainer submersible motor
H [m] ____________ max. 21 pump starting and stopping automatically and swing check valve. Automated with
switchgears and LevelControl.
T [°C] _ _________ max. +40
Applications: Wash-basins, showers, washing machines, garage gateways, base-
Data for 50 Hz operation
ments, rooms subject to a flooding risk, etc.

Reference no. 2331.55-10

mini-Compacta Floodable sewage lifting unit

Design: Floodable single-pump or dual-pump sewage lifting unit for automatic


DN ______________ 32 - 100 disposal of domestic sewage and faeces below the flood level. Automated with
Q [m3/h] _________ max. 36 LevelControl.
H [m] ____________ max. 25 Applications: Basement flats, bars, basement party rooms and saunas, cinemas
T [°C] _ _________ max. +40 and theatres, department stores and hospitals, hotels, restaurants, schools, etc.
Data for 50 Hz operation

Reference no. 2317.54-10

Compacta® Floodable sewage lifting unit

Design: Floodable single-pump or dual-pump sewage lifting unit for automatic


DN ______________ 80 - 100 disposal of sewage and faeces below the flood level. Automated with LevelControl.
Q [m3/h] ________ max. 140
Applications: Basement flats, bars, basement party rooms and saunas, cinemas
H [m] ____________ max. 24
and theatres, department stores and hospitals, hotels, restaurants, schools, public
T [°C] _ _______ max. +40*
buildings, industrial plants, joint sewage disposal for rows of houses, etc.
Data for 50 Hz operation

* up to +65 °C for short periods

Reference no. 2317.55-10

Pumping Station CK 800-Eu Pumping station, plastic collecting tank with Amarex N S and Ama-Porter

Design: Ready-to-connect package single or dual pumping station with PE-LLD


DN _______________ 32 - 50 (polyethylene) collecting tank for underground installation. Equipped with one or
Q [m3/h] _________ max. 22 two Amarex N S and Ama-Porter submersible waste water pumps without explo-
H [m] ____________ max. 49 sion protection. Collecting tank design to DIN 1986-100 and EN 752 / EN 476.
T [°C] _ _________ max. +40 Automated with LevelControl.
Data for 50 Hz operation
Applications: Renovation of premises, sewage disposal in various sectors, joint
sewage disposal for several residential units, pumped drainage.

A Reference no. 2334.541-10

Factory-automated 33
Lifting units / collecting tanks

Ama-Porter CK Pumping Station Pumping station, plastic collecting tank with Ama-Porter

Design: Ready-to-connect package single or dual pumping station with PE-LLD


DN _______________ 50 - 65 (polyethylene) collecting tank for underground installation. Equipped with one or
Q [m3/h] _________ max. 40 two Ama-Porter submersible waste water pumps without explosion protection.
H [m] ____________ max. 21 Collecting tank design to DIN 1986-100 and EN 752 / EN 476. Automated with
T [°C] _ _________ max. +40 switchgears and LevelControl.
Data for 50 Hz operation
Applications: Renovation of premises, sewage disposal in various sectors, joint
sewage disposal for several residential units, pumped drainage.

A Reference no. 2334.51-10

Amarex N CK Pumping Station Pumping station, plastic collecting tank with Amarex N

Design: Ready-to-connect package single or dual pumping station with PE-LLD


DN _______________ 50 - 65 (polyethylene) collecting tank for underground installation. Equipped with one or
Q [m3/h] _________ max. 50 two Amarex N submersible waste water pumps, also available with explosion pro-
H [m] ____________ max. 39 tection. Collecting tank design to DIN 1986-100 and EN 752 / EN 476. Automated
T [°C] _ _________ max. +40 with LevelControl.
Data for 50 Hz operation Applications: Renovation of premises, sewage disposal in various sectors, joint
sewage disposal for several residential units, pumped drainage.

LevelControl Reference no. 2334.52-10 

arch 2011 –
r sale until M
Evamatic-Box Released fo Ev am atic Box N. Sewage lifting unit
eded by
to be supers
Design: Single-pump or dual-pump sewage lifting unit with one or two Ama-Porter
DN _______________ 50 - 65 submersible waste water pumps with free-flow impeller (F) or cutter (S),
Q [m3/h] _________ max. 40 to EN 12050-1.
H [m] ____________ max. 21
Applications: Disposal of domestic waste water and sewage.
T [°C] _ _________ max. +40
Data for 50 Hz operation

LevelControl Reference no. 2319.51-10 

arch 2011 –
r sale until M
Evamatic-Box ICS Released fo atic Box N IC
S. Sewage lifting unit
eded by Evam
to be supers
Design: Single-pump or dual-pump sewage lifting unit with one or two Ama-Porter
DN _______________ 50 - 65 ICS submersible waste water pumps with free-flow impeller (F) or cutter (S) and ICS
Q [m3/h] _________ max. 40 control system.
H [m] ____________ max. 21
Applications: Disposal of domestic waste water and sewage.
T [°C] _ _________ max. +40
Data for 50 Hz operation

LevelControl Reference no. 2319.52-10 

34 Factory-automated
Submersible motor pumps

Amarex N Submersible motor pump DN 32 to 100

Design: Vertical, single-stage submersible motor pump, for wet installation,


DN ______________ 32 - 100 stationary and transportable design. Amarex N pumps are floodable, single-stage,
Q [m3/h] ________ max. 190 single-entry close-coupled units which are not self-priming. ATEX-compliant version
H [m] ____________ max. 49 available.
T [°C] _ _________ max. +55 Applications: Handling of all types of waste water, especially untreated sewage
Data for 50 Hz operation containing long fibres and solid substances, fluids containing gas / air, as well as
raw, activated and digested sludge, dewatering / water extraction, drainage of
rooms and surfaces subject to a flooding risk.

Switchgears • LevelControl Reference no. 2563.5-10  also available in 60 Hz

Amarex KRT Submersible motor pump DN 40 to DN 700

Design: Vertical, single-stage submersible motor pump in close-coupled design,


DN ______________ 40 - 700 various impeller types, for wet or dry installation, stationary and transportable
Q [m3/h] ______ max. 10800 version. ATEX-compliant version available.
H [m] ___________ max. 100
Applications: Handling of all types of abrasive or aggressive waste water in water
T [°C] _ _________ max. +60
and waste water engineering as well as industry, especially untreated sewage
n [min-1] _______ max. 2900
­containing long fibres and solid substances, fluids containing gas / air, as well as
Data for 50 Hz operation
raw, activated and digested sludge; sea water desalination.

PumpDrive • Hyamaster • Amacontrol • Switchgears • LevelControl Reference no. 2553.5-10  also available in 60 Hz

Amarex KRT dry-installed, with cooling jacket Submersible motor pump DN 100 to DN 700

Design: Vertical, single-stage submersible motor pump in close-coupled design,


DN ____________ 100 - 700
various impeller types, dry installation.
Q [m3/h] ______ max. 10000
H [m] ___________ max. 100 Applications: Handling of all types of waste water in waste water engineering
p [bar] ___________ max. 10 and industry, especially sewage containing long fibres and solid substances, fluids
T [°C] _ _________ max. +40 containing gas / air, as well as raw, activated and digested sludge.
n [min-1] _______ max. 1450
Data for 50 Hz operation

PumpDrive • Hyamaster • Amacontrol • Switchgears • LevelControl Reference no. 2553.5-10  also available in 60 Hz

Amarex KRT wet/dry-installed, with energy-saving motor Submersible motor pump DN 80 to DN 200

Design: Horizontal or vertical single-stage submersible motor pump in close-


DN ______________ 80 - 200 coupled design, with various impeller types, for wet or dry installation, stationary
Q [m3/h] ________ max. 550 and transportable version, with energy-saving motor.
H [m] ____________ max. 25 Applications: Handling of all types of waste water in waste water engineering
T [°C] _ _________ max. +40 and industry, especially sewage containing long fibres and solid substances, fluids
n [min-1] _______ max. 1450 containing gas / air, as well as raw, activated and digested sludge.
Data for 50 Hz operation

PumpDrive • Hyamaster • Amacontrol • Switchgears • LevelControl Reference no. 2553.5-10  also available in 60 Hz

Automation possible 35
Submersible pumps in discharge tubes

Amacan K Submersible motor pump with non-clogging impeller

Design: Wet-installed submersible motor pump with non-clogging impeller, single-


DN ___________ 700 - 1400 stage, single-entry, for installation in discharge tubes. ATEX-compliant version
Q [m3/h] _______ max. 7200 available.
H [m] ____________ max. 30
Applications: Handling of pre-cleaned, chemically neutral waste water, industrial
T [°C] _ _________ max. +40
effluents and sewage, fluids not containing any stringy substances pre-treated by
n [min-1] ________ max. 980
screens and sills, as waste water, mixed water and activated sludge pump in
Data for 50 Hz operation
effluent treatment plants, irrigation and drainage pumping systems.

Hyamaster • Amacontrol Reference no. 1579.5-10  also available in 60 Hz

Amacan P Submersible motor pump with axial propeller

Design: Wet-installed, submersible motor pump with axial propeller in ECB design
DN ___________ 500 - 1500 for installation in discharge tubes, single-stage, single-entry. ATEX-compliant
Q [m3/h] ______ max. 25200 version available.
H [m] ____________ max. 12
Applications: Irrigation and drainage pumping stations, stormwater pumping
T [°C] _ _________ max. +40
stations, handling of raw and clean water in water and effluent treatment plants,
n [min-1] _______ max. 1450
of cooling water in power stations and industrial plants, industrial water supply
Data for 50 Hz operation
systems, water pollution and flood control systems, aquaculture.

Hyamaster • Amacontrol Reference no. 1580.5-10  also available in 60 Hz

Amacan S Submersible motor pump with mixed flow impeller

Design: Wet-installed submersible motor pump with mixed flow impeller, single-
DN ___________ 650 - 1300 stage, for installation in discharge tubes. ATEX-compliant version available.
Q [m3/h] ______ max. 10800
Applications: Handling of water without stringy substances in irrigation and
H [m] ____________ max. 40
drainage pumping systems, general water supply systems, water pollution and
T [°C] _ _________ max. +30
flood control systems.
n [min-1] _______ max. 1450
Data for 50 Hz operation

Hyamaster • Amacontrol Reference no. 1589.5-10  also available in 60 Hz

Mixers / agitators / tank cleaning units

Amamix Submersible mixer

Design: Horizontal submersible mixer with self-cleaning ECB propeller, close-


Propeller ø [mm] __ 200 - 600 coupled design, direct drive or with gear unit. ATEX-compliant version available.
Install. depth [m] __ max. 30
Applications: Handling of municipal and industrial waste water and sludges, also
T [°C] _ _________ max. +40
in environmental engineering (biogas plants, etc.).
n [min-1] _______ max. 1400
Data for 50 Hz operation

Reference no. 1592.551-10 / 1592.552-10  also available in 60 Hz

36 Automation possible
Mixers / agitators / tank cleaning units

Amaprop Submersible agitator

Design: Horizontal submersible agitator with self-cleaning ECB propeller, close-


Propeller ø [mm] __ 1000 - 2500 coupled design, equipped with coaxial spur gear. ATEX-compliant version available.
Install. depth [m] __ max. 30
Applications: In environmental engineering, particulary for circulating, keeping in
T [°C] _ _________ max. +40
suspension and inducing flow in municipal and industrial waste water and sludges;
n [min-1] ________ max. 109
in nitrification and denitrification tanks, activated sludge tanks, mixing tanks, final
storage tanks, biological phosphate elimination tanks, flocculation tanks and in
biogas applications.

Reference no. 1592.505-10

Amajet Cleaning system

Design: Stationary or portable unit with horizontal or vertical submersible motor


DN _____________ 100 - 150 propulsive jet pump with non-clogging free-flow impeller. Motor rating 5.5 to
Q [m3/h] ________ max. 195 27 kW. Available variants: Amajet, SewerAmajet, SwingAmajet, MultiAmajet.
T [°C] _ _________ max. +40
Applications: Cleaning of stormwater tanks and storage sewers.
n [min-1] _______ max. 1450

Reference no. 1574.5-10

Amaline Submersible motor recirculation pump

Design: Wet-installed, horizontal propeller pump with submersible motor,


DN _____________ 300 - 800 equipped with spur gear or direct drive, ECB propeller with 3 rigid, fibre-repellent
Q [m3/h] _______ max. 5400 blades, bolt-free connection to the discharge pipe. ATEX-compliant version
H [m] _____________ max. 2 available.
T [°C] _ _________ max. +40
Applications: Recirculation of activated sludge in waste water treatment systems.
n [min-1] ________ max. 960

Reference no. 1594.5-10

Pumps for solids-laden fluids

Sewatec / Sewabloc Dry-installed volute casing pump

Design: Horizontal or vertical volute casing pump with free-flow (F), single vane
DN ______________ 50 - 700
(E), multi-vane (K) and diagonal single vane (D) impellers, discharge flange to DIN
Q [m3/h] ______ 60 - 10000
and ANSI standards. ATEX-compliant version available.
H [m] ____________ max. 95
p [bar] ___________ max. 10 Applications: Handling of sewage and all types of waste water in waste water
T [°C] _ _________ max. +70 management and industry.
n [min-1] _______ max. 2900
Data for 50 Hz operation

Hyamaster • PumpDrive • LevelControl Reference no. 2580.5-10/2580.45-10/2580.35-10  also available in 60 Hz

Automation possible 37
Pumps for solids-laden fluids

KWP / KWP-Bloc Non-clogging impeller centrifugal pump / close-coupled unit

DN ___ 40 - 900 (max. 1000) Design: Horizontal, radially split volute casing pump in back pull-out or close-
Q [m3/h] ______ max. 15000 coupled design, single-stage, single-entry, available with various impeller types:
_ ______________ (18000) non-clogging impeller, open multi-vane impeller, free-flow impeller.
H [m] ___________ max. 100 ATEX-compliant version available.
p [bar] ___________ max. 10
Applications: Handling of pre-treated sewage, waste water, all types of slurries
T [°C] _ _ +120 (max. +280)
n [min-1] _______ max. 2900 without stringy substances and pulps up to 5 % bone dry.
Data for 50 Hz operation

Hyamaster Reference no. 2361.5-10/2362.5-10/2361.450-10/2361.453-10/2361.460-10 also available in 60 Hz

Slurry pumps

WBC Slurry pump

Design: Patented design incorporates state-of-the art hydraulic and wear tech-
nologies for heavy-duty, high-pressure applications. The pump shell is designed to
Q [m3/h] ______ max. 13600 reduce stresses that can cause a structural failure during a pressure surge.
H [m] ____________ max. 80
Applications: Ideal for ore and tailings transport to minimize the effect of sudden
p [bar] ___________ max. 40
pressure spikes.
T [°C] _ ________ max. +120

LSA-S Slurry pump

Design: Premium design hard iron pumps for long wear life pumping severe
slurries. The basic, single-wall construction and heavy section, hard metal wet end
Q [m /h] ______ max. 14000
3

combined with the cartridge bearing assembly provides maximum reliability and
H [m] ____________ max. 90
ease of maintenance.
p [bar] ___________ max. 16
T [°C] _ ________ max. +120 Applications: Pumps are widely used in ore transport, mill discharge, cyclone feed,
tailings and plant process.

LCC-M Slurry pump

Design: The hydraulic wet end consists of three components: a shell or casing,
an impeller and a suction plate/liner to permit easy removal for maintenance and
Q [m3/h] _______ max. 3865
inspections.
H [m] ____________ max. 90
p [bar] ___________ max. 16 Applications: Reliable pumps for high discharge head, mildly corrosive slurries and
T [°C] _ ________ max. +120 a wide range of particle sizes. Used in mineral processing, mine dewatering, ash
and tailings.

38 Automation possible
Slurry pumps

LCC-R Slurry pump

Design: Interchangeable rubber and metal design allows best material choice
for any application. Easy wet end change can adapt existing pumps to new
Q [m /h] _______ max. 3865
3

applications.
H [m] ____________ max. 90
p [bar] ___________ max. 16 Applications: Pumps are suitable for moderate discharge heads, fine particles and
T [°C] _ ________ max. +100 highly corrosive slurries.

TBC Slurry pump

Design: A high-pressure design, these pumps are constructed as horizontal, end


suction centrifugal pumps to give maximum resistance to wear while simplifying
Q [m3/h] ______ max. 18200
maintenance. The conventional single-wall design transfers stress loads to non-
H [m] ____________ max. 90
wearing side plates in high-pressure applications.
p [bar] ___________ max. 55
T [°C] _ ________ max. +120 Applications: Features high head and high flow rates for hydrotransport, tailings,
dredging, pipeline booster stations and other severe duties.

LSR Slurry pump

Design: Extra heavy-duty pumps with a high-grade rubber lining for hard wearing
applications. The key to the LSR‘s success is its endurance.
Q [m3/h] _______ max. 9000
Applications: Designed for heavy-duty mill circuit and fine grind slurries; specific-
H [m] ____________ max. 60
ally copper, iron ore, gold, aggregate and other abrasive applications.
p [bar] ___________ max. 14
T [°C] _ ________ max. +120

LCV Slurry pump

Design: Vertical cantilever, rugged hard metal sump pump with bottom ­suction
and no submerged bearings. Replaceable wet end parts in metal alloys with a
Q [m /h] _______ max. 1360
3

durable mechanical end.


H [m] ____________ max. 38
p [bar] ___________ max. 14 Applications: Ideal for industrial process pumping, tailings disposal in mining and
T [°C] _ ________ max. +120 pit use.

FGD Slurry pump

Design: High-flow/low-head hard metal pumps with a single-wall shell design.


High-efficiency impeller. Suction-side liner is equipped with integrated mounting
Q [m3/h] ______ max. 22700
plates.
H [m] ____________ max. 45
p [bar] ___________ max. 17 Applications: Absorber recirculation and ancillary process pumps.
T [°C] _ ________ max. +120

39
Slurry pumps

Mega Slurry pump

Design: Horizontal, end suction, modified volute casing pump includes 3 vane
open design impeller for large solids passage.
Q [m /h] _________ max. 45
3

H [m] ____________ max. 30 Applications: High-performance, low maintenance slurry pump recommended for
p [bar] ___________ max. 24 coarse or fine particles from solids-laden waste water to aggressive slurries of an
T [°C] _ ________ max. +120 abrasive and/or corrosive nature.

HHD Slurry pump

Design: Best suited for high-flow, high-head pumping where high production
requires the reduction in the number of pumps.
Q [m3/h] ______ max. 14400
H [m] ____________ max. 90 Applications: Ideal for pipeline booster stations and severe mining duties.
p [bar] ___________ max. 29 Also, as booster or main hull pump on cutter suction dredges.
T [°C] _ ________ max. +120

MHD Slurry pump

Design: Designed to provide high flow/medium head with high efficiency for high
volume transportation in long pipelines.
Q [m /h] ______ max. 32000
3

H [m] ____________ max. 80 Applications: Ideal for pipeline booster stations and severe mining duties.
p [bar] ___________ max. 28 Also for hopper dredges or as main pump on cutter dredges.
T [°C] _ ________ max. +120

LHD Slurry pump

Design: High-flow/low-head design with balanced NPSHR and sphere passage for
high volume transportation over short distance.
Q [m3/h] ______ max. 21600
H [m] ____________ max. 65 Applications: Ideal for sand & gravel, severe mining, dredge ladder and
p [bar] ___________ max. 17 booster pumps.
T [°C] _ ________ max. +120

MDX Slurry pump

Design: The latest technology from GIW provides superior wear life and increased
up-time handling your most aggressive slurry applications.
Q [m3/h] ______ max. 14000
H [m] ____________ max. 90 Applications: Designed for SAG and ball mill discharge duties as well as cyclone
p [bar] ___________ max. 16 feed and screen feed applications in ore mining.
T [°C] _ ________ max. +120

40
Slurry pumps

ZW Slurry pump

Design: Vertical cantilever, rugged hard metal sump pumps with top and bottom
suction, not submerged bearings. Replaceable wet end parts in metal alloys with a
Q [m3/h] ________ max. 400
durable mechanical end.
H [m] ____________ max. 35
p [bar] ___________ max. 10 Applications: Abrasive slurries, dewatering, floor clean up, and process transfer.
T [°C] _ ________ max. +120

Self-priming pumps

Etaprime L Self-priming pump for pure or contaminated liquids

Design: Horizontal, long-coupled, self-priming volute casing pump in back pull-out


DN ______________ 25 - 125 design, single-stage, with open multi-vane impeller. ATEX-compliant version
Q [m3/h] ________ max. 180 available.
H [m] ____________ max. 85
Applications: Handling of pure, contaminated or aggressive liquids not containing
p [bar] ___________ max. 10
abrasive substances and / or solids.
T [°C] _ _________ max. +90
Data for 50 Hz operation

Reference no. 2745.5-10  also available in 60 Hz

Etaprime B / BN Self-priming close-coupled pump for pure or contaminated liquids

Design: Horizontal, self-priming volute casing pump, single-stage, with open multi-
DN ______________ 25 - 100 vane impeller, in close-coupled design, with common pump and motor shaft (B) or
Q [m3/h] ________ max. 130 rigidly connected (BN). ATEX-compliant version available.
H [m] ____________ max. 72
Applications: Handling of pure, contaminated or aggressive liquids not containing
p [bar] ___________ max. 10
abrasive substances and / or solids.
T [°C] _ _________ max. +90
Data for 50 Hz operation

Reference no. 2746.5-10  also available in 60 Hz

41
Submersible borehole pumps

S 100D / UPA 100C Submersible borehole pump

Design: Multistage centrifugal pump in ring-section design, for vertical or horizontal


installation, impellers made of plastic (S 100D) or stainless steel (UPA 100C) for well
DN __________________ 100
diameters of 100 mm (4 inches) and above, available with single-phase a.c. motor or
Q [m3/h] _________ max. 16
three-phase motor with motor lead.
H [m] ___________ max. 400
T [°C] _ _________ max. +30 Applications: Domestic water supply, irrigation and spray irrigation systems, lower-
Data for 50 Hz operation ing of ground water levels, fire-fighting systems, cooling circuits, fountains, pressure
boosting and air-conditioning systems.

Switchgears • Cervomatic Reference no. 3400.5-10  also available in 60 Hz

UPA 150C Submersible borehole pump

Design: Single-stage or multistage centrifugal pump in ring-section design, for


vertical or horizontal installation, completely made of stainless steel, for well diam-
DN __________________ 150
eters of 150 mm (6 inches) and above.
Q [m3/h] _________ max. 79
H [m] ___________ max. 570 Applications: Handling of clean or slightly contaminated water, irrigation and
T [°C] _ _________ max. +50 drainage, spray irrigation, industrial and municipal water supply, maintaining /
Data for 50 Hz operation ­lowering of groundwater levels, fire-fighting systems, drinking, raw and service
water supply, pressure ­boosting.

Hyamaster • PumpDrive Reference no. 3400.52-10  also available in 60 Hz

UPA 200, 200B, 250C Submersible borehole pump

Design: Single-stage or multistage single-entry centrifugal pump in ring-section


design for vertical or horizontal installation. Available with non-return valve or con-
DN _____________ 200 - 250
nection branch.
Q [m3/h] ________ max. 330
H [m] ___________ max. 460 Applications: Handling of clean or slightly contaminated water in general water
T [°C] _ _________ max. +50 supply, irrigation and spray irrigation systems, maintaining / lowering of ground
Data for 50 Hz operation water levels, fountains, pressure boosting systems, in mines, fire-fighting systems,
emergency water supply systems, etc.

Hyamaster Reference no. 3400.5-10  also available in 60 Hz

UPA 300, 350 Submersible borehole pump

Design: Single- or multistage, single-entry centrifugal pump in ring-section design


for vertical or horizontal installation. Non-return valve or connection branch on
DN _____________ 300 - 350
option. Mixed flow hydraulic systems available with reduced impeller diameters.
Q [m3/h] ________ max. 840
H [m] ___________ max. 480 Applications: Handling of clean or slightly contaminated water in general water
T [°C] _ _________ max. +50 supply, irrigation and spray irrigation systems, maintaining / lowering of ground
Data for 50 Hz operation water levels, in mines, fire-fighting systems, fountains, etc.

Hyamaster Reference no. 3400.5-10  also available in 60 Hz

UPZ, BSX-BSF Submersible borehole pump

Design: Single- or multistage, single-entry (BSX-BSF) or double-entry (UPZ)


centrifugal pump in ring-section design for vertical or horizontal installation.
DN ________________ > 350
Q [m3/h] _______ max. 2200 Applications: Handling of clean or slightly contaminated water, maintaining /
H [m] __________ max. 1500 lowering of ground water levels, in mines.
T [°C] _ _________ max. +50
Data for 50 Hz operation

Reference no. 3470.021-10  also available in 60 Hz

42 Automation possible
High-pressure pumps, fixed / variable speed

Movitec V / LHS / VS / VC High-pressure in-line pump

Design: Multistage, vertical high-pressure centrifugal pump in ring-section design


DN ______________ 25 - 100
with suction and discharge nozzles of identical nominal diameters arranged oppos-
Q [m3/h] ________ max. 113
ite to each other (in-line design), close-coupled. ATEX-compliant version available.
H [m] ___________ max. 401
p [bar] ___________ max. 40 Applications: Spray irrigation, irrigation, washing, water treatment, fire-fighting
T [°C] _ ________ max. +140 and pressure boosting systems, hot water and cooling water recirculation, boiler
n [min-1] _______ max. 2900 feed systems, etc.
Data for 50 Hz operation

PumpMeter • Hyamaster Reference no. 1798.5-10  also available in 60 Hz

Movitec PumpDrive High-pressure in-line pump with motor-mounted variable speed system

Design: Multistage, vertical high-pressure centrifugal pump in ring-section


DN ______________ 25 - 100 design with suction and discharge nozzles of identical nominal diameters arranged
Q [m3/h] ________ max. 113 opposite to each other (in-line design), close-coupled and motor-mounted variable
H [m] ___________ max. 401 speed system.
p [bar] ___________ max. 40
Applications: Spray irrigation, irrigation, washing, water treatment, fire-fighting
T [°C] _ ________ max. +140
and pressure boosting systems, hot water and cooling water recirculation, boiler
n [min-1] _______ max. 2900
feed systems, etc.

PumpMeter Reference no. 1798.5-10 + 4070.5-10  also suitable for 60 Hz operation

Multitec High-pressure pump in ring-section design

Design: Multistage horizontal or vertical centrifugal pump in ring-section design,


DN ______________ 32 - 150
long-coupled and close-coupled variant, with axial or radial suction nozzle, cast
Q [m3/h] ________ max. 850
radial impellers. ATEX-compliant version available.
H [m] ______ max. 630 (800)
p [bar] _______ max. 63 (80) Applications: Water and drinking water supply systems, general industry, pressure
T [°C] _ ______ -10 to +200 boosting systems, irrigation systems, in power stations, heating, filter, fire-fighting,
n [min-1] _______ max. 4000 reverse osmosis and washing plants, snow guns, etc.
Data for 50 Hz operation

Hyamaster Reference no. 1777.5-10  available in 50 Hz and 60 Hz

Multitec PumpDrive High-pressure pump in ring-section design with motor-mounted variable speed system

Design: Multistage horizontal or vertical centrifugal pump in ring-section design,


DN ______________ 32 - 125 long-coupled and close-coupled variant, with axial or radial suction nozzle, cast
Q [m3/h] ________ max. 180 radial impellers and motor-mounted variable speed system.
H [m] ___________ max. 630
Applications: Water and drinking water supply systems, general industry, pressure
p [bar] ___________ max. 63
boosting systems, irrigation systems, in power stations, heating, filter, fire-fighting,
T [°C] _ ________ max. +110
reverse osmosis and washing plants, snow guns, etc.
n [min-1] _______ max. 4000

Reference no. 1777.5-10 + 4070.5-10  also suitable for 60 Hz operation

Factory-automated Automation possible 43


Axially split pumps

Omega Axially split volute casing pump DN 80 - 350

DN ______________ 80 - 350 Design: Single-stage, axially split volute casing pump for horizontal or vertical
Q [m3/h] _______ max. 2880 installation, with double-entry radial impeller, mating flanges to DIN, ISO, BS
H [m] ___________ max. 170 or ANSI.
p [bar] ___________ max. 25 Applications: Handling of raw, pure and service water as well as seawater in
T [°C] _ _________ max. +70 water treatment plants, irrigation and drainage pumping stations, power stations,
n [min-1] _______ max. 2900 fire-fighting systems, shipbuilding and the petrochemical industry.
Data for 50 Hz operation,
higher values available upon request

Hyamaster Reference no. 1384.5-10  also available in 60 Hz

RDLO Axially split volute casing pump DN 350 - 700

DN _____________ 350 - 700 Design: Single-stage, axially split volute casing pump for horizontal or vertical
Q [m3/h] ______ max. 10000 installation with double-entry radial impeller, mating flanges to DIN, ISO, BS
H [m] ___________ max. 240 or ANSI.
p [bar] ___________ max. 25 Applications: Handling of raw, pure and service water as well as seawater in
T [°C] _ _________ max. +70 water treatment plants, irrigation and drainage pumping stations, in power
n [min-1] _______ max. 1450 stations, fire-fighting systems, shipbuilding and the petrochemical industry.
Data for 50 Hz operation,
higher values available upon request

Hyamaster Doku-Nr. 1385.51-10/1387.5 -10 also available in 60 Hz

Hygienic pumps for the food, beverage and pharmaceutical


industries

Vitachrom Rolled steel centrifugal pump

Design: Maintenance-friendly annular casing pump, close-coupled with stand-


DN ______________ 50 - 125 ardised motor, all wetted components made of 316L stainless steel. Certified by
Q [m3/h] ________ max. 340 the TNO Nutrition and Food Research Institute to EHEDG standards for processing
H [m] ___________ max. 100 food products.
p [bar] ___________ max. 12
Applications: Hygienic handling of fluids in the food, beverage and pharmaceuti-
T [°C] _ ________ max. +110
cal industries as well as in the chemical industry.
Data for 50 Hz operation

Hyamaster • PumpDrive Reference no. 1966.5-10  also available in 60 Hz

Vitacast / Vitacast E Investment cast centrifugal pump

Design: Maintenance-friendly volute casing pump with standardised motor, all


DN ______________ 25 - 150
wetted components made of 316L stainless steel. Hygienic design for the highest
Q [m3/h] ________ max. 560
requirements on cleanability (CIP/SIP-compatible), certified by the TNO Nutrition
H [m] ___________ max. 100
and Food Research Institute to EHEDG standards (Vitacast E).
p [bar] ___________ max. 10
T [°C] _ ________ max. +100 Applications: Hygienic handling of fluids in the food, beverage and pharmaceuti-
Data for 50 Hz operation,
cal industries as well as in the chemical industry.
other values available upon request

PumpDrive Reference no. 1969.51 / 1969.52  also available in 60 Hz

44 Automation possible
Hygienic pumps for the food, beverage and pharmaceutical
industries

Vitaprime Self-priming centrifugal pump

Design: Maintenance-friendly, self-priming side channel pump in close-coupled


DN _______________ 40 - 80
design with standardised motor, all wetted components made of 316L stainless
Q [m3/h] _________ max. 55
steel. Hygienic design for the highest requirements on cleanability (CIP/SIP-
H [m] ____________ max. 43
compatible).
p [bar] ____________ max. 4
T [°C] _ ________ max. +100 Applications: Hygienic handling of fluids in the food, beverage and pharmaceuti-
Data for 50 Hz operation,
cal industries as well as in the chemical industry.
other values available upon request

PumpDrive Reference no. 1969.54  also available in 60 Hz

Vitastage Multistage centrifugal pump

Design: Multistage centrifugal pump in close-coupled design for vertical or


Q [m3/h] _________ max. 40 horizontal installation. All wetted components made of 316 stainless steel.
H [m] ___________ max. 150 Applications: Processes in the food and beverage industry as well as in the
p [bar] ___________ max. 16 chemical industry with moderate hygienic requirements.
T [°C] _ ________ max. +100
Data for 50 Hz operation,
other values available upon request

Reference no. 1969.55  also available in 60 Hz

Vitalobe Rotary lobe pump

DN _________ 25 - 200 (1“ - 8“) Design: Sturdy rotary lobe pump in hygienic design, bi-directional operation pos-
Q [m3/h] _____________ max. 300 sible, horizontal and vertical orientation of connections. Hygienic design, all wetted
H [m] _______________ max. 200
components made of 316L stainless steel; various rotor types and process connec-
p [bar] _______________ max. 30
T [°C] ____________ -40 to +200
tions available. Pump set with geared motor.
Viscosity [cP]_______ ≤ 3000000 Applications: Hygienic and gentle handling of sensitive or high-viscosity fluids in
Volume displaced______________ the food, beverage and pharmaceutical industries as well as in the chemical indus-
[litres per revolution]_ __ max. 10,5 try and general process engineering.
Data for 50 Hz operation,
other values available upon request

PumpDrive Reference no. 1969.53  also available in 60 Hz

Pumps for power station conventional islands

CHTA / CHTC / CHTD Boiler feed pump

DN _____________ 100 - 500 Design: Horizontal, high-pressure barrel-type pump with radial impellers, single-
Q [m3/h] _______ max. 3700 and double-entry, multistage, with flanges / weld end nozzles to DIN and ANSI.
H [m] __________ max. 5300 Applications: Handling of feed water and condensate in power stations and
p [bar] __________ max. 560 industrial facilities, generation of pressurized water for bark peeling machines and
T [°C] _ ________ max. +210 descaling equipment.
n [min-1] _______ max. 6750
Data for 50 Hz operation,
higher values available upon request

Reference no. 1860.1-10  also available in 60 Hz

Automation possible 45
Pumps for power station conventional islands

CHTR Boiler feed pump

DN _______________ 50 - 150 Design: Horizontal, high-pressure barrel-type pump with radial impellers, single-
Q [m3/h] ________ max. 900 and double-entry, multistage, with flanges / weld end nozzles to DIN, API 610
H [m] __________ max. 2500 and ANSI.
p [bar] __________ max. 250 Applications: In refineries, in the petrochemical industry and in steam generation
T [°C] _ ________ max. +400 plants.
n [min-1] _______ max. 7000
Data for 50 Hz operation,
higher values available upon request

Reference no. 2701-10 also available in 60 Hz

HGB / HGC / HGD Boiler feed pump

DN ______________ 40 - 400 Design: Horizontal, radially split, multistage ring-section pump with radial
Q [m3/h] _______ max. 2300 impellers, single- or double-entry.
H [m] __________ max. 5300 Applications: Handling of feed water and condensate in power stations and
p [bar] __________ max. 560 industrial facilities, generation of pressurized water for bark peeling machines,
T [°C] _ ________ max. +210 descaling equipment, snow guns, etc.
n [min-1] _______ max. 7000
Data for 50 Hz operation,
higher values available upon request

Reference no. 1850.02-10  also available in 60 Hz

HGM Boiler feed pump

DN ______________ 25 - 100 Design: Horizontal, radially split, product-lubricated, multistage ring-section pump
Q [m3/h] ________ max. 274 with radial impellers, axial and radial single-entry inlet.
H [m] __________ max. 1400 Applications: Handling of feed water in power stations, boiler feed water and
p [bar] __________ max. 140 ­condensate in industrial facilities.
T [°C] _ ________ max. +160
n [min-1] _______ max. 3600
Data for 50 Hz operation,
higher values available upon request

Reference no. 1856.02-10  also available in 60 Hz

YNK / KRHA Boiler feed booster pump

DN _____________ 125 - 600 Design: Horizontal, radially split, single-stage, double-entry boiler feed booster
Q [m3/h] _______ max. 3700 pump (booster system) with single or double cast steel volute casing.
H [m] ___________ max. 280 Applications: Handling of feed water in power stations and industrial facilities.
p [bar] ___________ max. 40
T [°C] _ ________ max. +210
n [min-1] _______ max. 1800
Data for 50 Hz operation,
higher values available upon request

Reference no. 1130.5-10  also available in 60 Hz

RHD Feed water pump

DN _____________ 250 - 400 Design: Horizontal, single-stage, double-entry feed water pump, cast and forged
Q [m3/h] _______ max. 6500 variant.
H [m] __________ max. 1000 Applications: Handling of feed water in steam generation systems of nuclear
p [bar] __________ max. 150 power stations.
T [°C] _ ________ max. +210
n [min-1] _______ max. 6500
Data for 50 Hz operation,
higher values available upon request

 also available in 60 Hz

46
Pumps for power station conventional islands

LUV / LUVA Boiler recirculation pump

DN _____________ 100 - 550 Design: Vertical spherical casing pump, radial impellers, single-entry, single- to
Q [m3/h] _______ max. 7000 three-stage. Suitable for very high inlet pressures and temperatures. Integrated wet
H [m] ___________ max. 275 winding motor to VDE. Product-lubricated bearings, no need for oil supply systems.
p [bar] __________ max. 320 Design to TRD or ASME.
T [°C] _ ________ max. +420 Applications: Hot water recirculation in forced-circulation, forced-flow and
n [min-1] _______ max. 3600 combined-circulation boilers for very high pressures.
Data for 50 Hz operation,
higher values available upon request

Reference no. 0361.033-10  also available in 60 Hz

WKT / WKTA / WKTB Condensate pump

DN ______________ 40 - 300 Design: Vertical, multistage, can-type ring-section pump with radial and mixed
Q [m3/h] _______ max. 1800 flow impellers. Single- and double-entry suction impellers, flanges to DIN or ANSI.
H [m] ___________ max. 340 The can is arranged in a pit below the installation floor. The pump is connected
p [bar] ___________ max. 40 with the structure by means of a baseplate.
T [°C] _ ________ max. +100 Applications: Handling of condensate in power stations and energy systems.
n [min-1] _______ max. 1800
Data for 50 Hz operation,
higher values available upon request

Reference no. 0361.033-10  also available in 60 Hz

SEZ / SEZT / PHZ / PNZ Cooling water pump

Design: Vertical tubular casing pump with open mixed flow impeller (SEZ), mixed
Q [m3/s] _ ________ max. 22 flow propeller (PHZ) or axial propeller (PNZ). Pump inlet with bellmouth or suction
H [m] ___________ max. 100 elbow, pull-out design available, discharge nozzle arranged above or below floor,
T [°C] _ _________ max. +40 flanges to DIN or ANSI standards available.
n [min-1] ________ max. 980 Applications: Handling of raw, pure, service and cooling water in industry, water
Data for 50 Hz operation,
higher values available upon request
supply systems, in power stations and seawater desalination plants.

Reference no. 1471.02-10  also available in 60 Hz

SNW / PNW Cooling water pump

DN _____________ 350 - 800 Design: Vertical tubular casing pump with mixed flow impeller (SNW) or axial
Q [m3/h] _______ max. 9000 propeller (PNW), single-stage, with maintenance-free Residur shaft bearings,
H [m] ____________ max. 50 discharge nozzle arranged above or below floor.
p [bar] ___________ max. 10 Applications: Irrigation and drainage systems, stormwater pumping stations,
T [°C] _ _________ max. +60 hand­ling of raw and pure water, water supply systems, handling of cooling water.
n [min-1] _______ max. 1500
Data for 50 Hz operation,
higher values available upon request

Reference no. 1481.5-10/1591.5-10  also available in 60 Hz

SPY Cooling water pump

DN ___________ 350 - 1200 Design: Long-coupled, single-stage volute casing pump in back pull-out design.
Q [m3/h] ______ max. 21600 Applications: Drainage, irrigation and water supply systems, handling of conden-
H [m] ____________ max. 50 sate, cooling water, service water, etc.
p [bar] ___________ max. 10
T [°C] _ ________ max. +105
n [min-1] _______ max. 1480
Data for 50 Hz operation,
higher values available upon request

Reference no. 2384.51-10  also available in 60 Hz

47
Pumps for power station nuclear islands

RER Reactor coolant pump

DN _____________ max. 800 Design: Vertical, single-stage reactor coolant pump with forged annular casing
Q [m3/h] ______ max. 40000 plated on the inside, with diffuser, either with own pump thrust bearing or
H [m] ___________ max. 140 supported by motor bearing.
p [bar] __________ max. 175 Applications: Reactor coolant recirculation in nuclear power stations (PWR).
T [°C] _ ________ max. +350
n [min-1] _______ max. 1800
Data for 50 Hz operation,
higher values available upon request

 also available in 60 Hz

RSR Reactor coolant pump

DN _____________ max. 600 Design: Vertical, single-stage reactor coolant pump, with cast double volute
Q [m3/h] _______ max. 9000 casing, supported by motor bearing.
H [m] ___________ max. 215 Applications: Reactor coolant recirculation in nuclear power stations
p [bar] __________ max. 125 (PWR, PHWR).
T [°C] _ ________ max. +310
n [min-1]________ max. 1800
Data for 50 Hz operation,
higher values available upon request

PSR Reactor internal pump

DN _____________ max. 600 Design: Vertical pump set integrated in the reactor pressure vessel, glandless
Q [m3/h] _______ max. 9000 pump with leak-free, low-maintenance wet winding motor.
H [m] ____________ max. 45 Applications: Reactor coolant recirculation in boiling water reactors (BWR).
p [bar] ___________ max. 75
T [°C] _ ________ max. +300
n [min-1] _______ max. 2000
Data for 50 Hz operation,
higher values available upon request

 also available in 60 Hz

LUV - Nuclear Reactor coolant / reactor water clean-up pump

Design: Vertical pump with integrated motor, single-entry, one to three stages.
DN ______________ 40 - 600
Suitable for very high inlet pressures and temperatures. Integrated wet winding
Q [m3/h] _______ max. 7000
motor to VDE. Product-lubricated bearings, no need for oil supply systems. Design
H [m] ___________ max. 300
to ASME Section 3, KTA, etc.
p [bar] __________ max. 320
T [°C] _ ________ max. +430 Applications: As reactor water clean-up pump in boiling water reactors, reactor
Data for 50 Hz operation,
coolant pump in boiling water and pressurized water reactors, and as recirculation
higher values available upon request pump in test facilities.

 also available in 60 Hz

RHM Pump for safety-related and auxiliary systems

DN _____________ max. 150 Design: Horizontal, multistage barrel pull-out pump.


Q [m3/h] ________ max. 300 Applications: Core flooding, emergency cooling and residual heat removal
H [m] __________ max. 2100 systems, volume control systems, high-pressure charging, control rod drive systems,
p [bar] __________ max. 220 high- and medium-pressure safety injection systems, auxiliary feed water systems,
T [°C] _ ________ max. +180 start-up and shutdown feed water systems.
n [min-1] _______ max. 8000
Data for 50 Hz operation,
higher values available upon request

 also available in 60 Hz

48
Pumps for power station nuclear islands

RVM Pump for safety-related and auxiliary systems

DN ______________ max. 85 Design: Vertical, multistage barrel pull-out pump.


Q [m3/h] _________ max. 50 Applications: Core flooding, emergency cooling and residual heat removal
H [m] __________ max. 2000 systems, volume control systems, high-pressure safety injection systems.
p [bar] __________ max. 200
T [°C] _ ________ max. +100
n [min-1] _______ max. 6000
Data for 50 Hz operation,
higher values available upon request

 also available in 60 Hz

RHR / RVR Pump for safety-related and auxiliary systems

Design: Horizontal or vertical annular casing pump with forged pressure boundary
DN _____________ max. 500
and diffuser.
Q [m3/h] _______ max. 6000
H [m] ___________ max. 190 Applications: Core flooding, emergency cooling and residual heat removal
p [bar] ___________ max. 63 systems, ancillary systems, acid feed systems and low-­pressure feed systems.
T [°C] _ ________ max. +200
n [min-1] _______ max. 3600
Data for 50 Hz operation

 also available in 60 Hz

RUV Reactor coolant pump

Design: Vertical, single-stage reactor coolant pump. Seal-less design with inte-
DN _____________ max. 710
grated wet winding motor and integrated flywheel. Product-lubricated bearings, no
Q [m3/h] ______ max. 22000
oil supply systems required.
H [m] ___________ max. 111
p [bar] __________ max. 155 Applications: Main coolant circulation in third-generation nuclear power stations.
T [°C] _ ________ max. +350
n [min-1] _______ max. 1800
higher values available upon request

 available in 50 Hz and 60 Hz

49
Pumps and pressure exchangers for seawater desalination
by reverse osmsis

SalTec System Hydraulic system

Design: Hydraulic system for pressure boosting and energy recovery in reverse
osmosis processes for seawater desalination.
Q [m /day] _______ ≥ 10000
3

p [bar] ___________ max. 80 Components: SalTec® DT pressure exchanger, HGM-RO high-pressure pump,
T [°C] _ _________ max. +40 RPH-RO booster pump and control unit.
Applications: Seawater desalination by reverse osmosis.

Reference no. 1858.11-10

SalTec DT Pressure exchanger

Description: Pressure exchanger specially developed for use in RO seawater


­desalination systems, in duplex stainless steel (standard) or super duplex stainless
Q [m3/h] ________ max. 280 steel (on request).
p [bar] ___________ max. 80
T [°C] _ _________ max. +40

Reference no. 1858.1-10

RPH-RO Booster pump

Design: Horizontal, radially split volute casing pump, dry-installed, made of


DN ______________ 25 - 400 duplex stainless steel (standard) or super duplex stainless steel (on request).
Q [m3/h] _______ max. 4150
Applications: Booster pump for RO seawater desalination systems.
H [m] ___________ max. 270
p [bar] __________ max. 104
T [°C] _ _________ max. +50
Data for 50 Hz operation

 also available in 60 Hz

HGM-RO High-pressure pump

DN ______________ 65 - 250 Design: Horizontal, radially-split, product-lubricated, multistage ring-section


Q [m3/h] _______ max. 1500 pump with radial impellers and plain bearings. Axial and radial single-entry inlet.
H [m] ___________ max. 950 Duplex stainless steel variant also suitable for chilled water applications.
p [bar] __________ max. 120 Applications: High-pressure pump for RO seawater desalination systems.
T [°C] _ _________ max. +40
n [min-1] _______ max. 3600
Data for 50 Hz operation,
higher values available upon request

Reference no. 1582.12-10  also available in 60 Hz

Multitec-RO High-pressure pump

Design: Horizontal, multistage pump in ring-section design. Axial suction nozzle,


DN ______________ 50 - 150
discharge nozzle can be turned in steps of 90°. Closed radial impellers. In duplex or
Q [m3/h] ________ max. 850
super-duplex stainless steel.
H [m] __________ max. 1000
p [bar] __________ max. 100 Applications: High-pressure pump for RO seawater desalination systems.
T [°C] _ _________ max. +40
n [min-1]________ max. 4000
Data for 50 Hz operation

Hyamaster • PumpDrive Reference no. 1777.13-10  available in 50 Hz and 60 Hz

50 Factory-automated Automation possible


Control units

Controlmatic E.2 Automatic control unit

Design: Single-pump control system for starting, stopping and monitoring pumps.
Applications: Water supply systems, in combination with pumps like Multi Eco,
No. of pumps ______ max. 1
Multichrom S, Ixo, S 100D, etc.
Voltage [V] ________ 1∼230

Reference no. 5125.1785-10

Cervomatic EDP.2 Automatic control unit

Design: Single-pump control unit for pressure-controlled starting and either


pressure-controlled or flow-controlled stopping as well as monitoring pumps.
No. of pumps ______ max. 1
Applications: In water supply systems using, for example, Multi Eco, Ixo, S 100D
Voltage [V]___ 1∼230 / 3∼400
and UPA 150C.

Reference no. 5125.178-10

LevelControl Level control unit

Design: Level control unit for controlling up to two pumps. Direct starting up to
4 kW, star-delta starting up to 22 kW.
No. of pumps _____ max. 2
[kW] _ ___________ max. 22 Applications: Tank drainage via float switches, pneumatic or bubbler control in
Voltage [V] ______ 230 / 400 building services and waste water applications.
higher values available upon request

Reference no. 4040.5-10, 4041.5-10

UPA Control Control system for submersible borehole pumps

Design: Single-pump control unit for submersible borehole pumps, submersible


motor pumps and dry-installed pumps.
No. of pumps ______ max. 1
[kW] _ _________________ 3 Applications: Water supply systems, in combination with pumps like S 100D,
Voltage [V]__ 1∼230 / 3∼400 UPA 150S, etc.

Reference no. 3465.1-10

hyatronic N Pump control system for cascade starting and stopping

Design: Pump control system in control cabinet for cascade starting and stopping
of up to 6 pumps on the mains.
No. of pumps ______ max. 6
[kW] _ ________________ 22 Applications: Water supply systems.
Voltage [V] ________ 3∼400

Reference no. 0543.5026-10

51
Speed control

PumpDrive Self-cooling, motor-independent variable-speed system

Design: Self-cooling frequency inverter which allows the motor speed to be varied
continuously by means of standard signals and a field bus. Because PumpDrive is
No. of pumps ______ max. 6
self-cooling, it can be mounted on the motor, on the wall or in a cabinet. Control of up to
FI ______ 1 per pump/motor 6 pumps without an additional controller (with PumpDrive Advanced).
[kW] _ ________________ 45
Applications: Cooling circuits, filters, water supply systems, heating, ventilation and
Voltage [V]___ 3∼380 to 480
air-conditioning systems, spray irrigation systems, boiler feed systems, steam generation
plants, process engineering circuits, cooling lubricant supply systems, service water supply
systems and other process engineering applications.

Reference no. 4070.5-10

hyatronic spc Pump control system for continuously variable speed adjustment

Design: Single-pump control system for continuously variable speed adjustment


with integrated frequency inverter.
No. of pumps ______ max. 1
FI_ _______________ max. 1 Applications: Heating, ventilation, air-conditioning, water supply and drainage
[kW] _ _______________ 7.5 systems.
Voltage [V] ________ 3∼400

Reference no. 0973.5-10

hyatronic mb Pump control system for continuously variable speed adjustment

Design: Pump control system in control cabinet for asynchronous motors of all
No. of pumps ______ max. 8 types and makes for controlling and monitoring hydraulic systems.
FI_ _______________ max. 2
Applications: Heating, ventilation and air-conditioning systems, water supply and
[kW] _ _______________ 200
drainage systems.
Voltage [V] ________ 3∼400

Reference no. 0974.5-10

Hyamaster ISB Pump control system for continuously variable speed adjustment

Design: Control system for pumps with three-phase motors of all types and makes,
consisting of a KSB controller with display and control panel and all required power
No. of pumps ______ max. 8
components.
FI_ _______________ max. 2
[kW] _ _______________ 200 Applications: Industrial and process engineering circuits, service water supply,
Voltage [V]________ 3∼400 cooling and lubrication, energy supply in cogeneration plants, heat transfer and
district heating stations, water extraction and treatment, water supply and waste
water disposal.

Reference no. 1961.5-10

Hyamaster SPS Pump control system for continuously variable speed adjustment

Design: Control system for pumps with three-phase motors of all types and
No. of pumps______ max. 4 makes, consisting of a programmable logic controller (PLC) with display and control
FI_ ___________ 1 per pump panel and all required power components housed in a control cabinet.
[kW] _ _______________ 650
Applications: Process engineering circuits, service water supply, cooling and
Voltage [V] ________ 3∼400
lubrication systems, cogeneration plants, heat transfer and district heating stations,
water extraction and treatment, water supply and waste water disposal.

Reference no. 1964.5-10

52
Monitoring and diagnostic systems

PumpMeter Intelligent pressure transmitter

Design: The PumpMeter device is an intelligent pressure transmitter for pumps,


No. of pumps ______ max. 1 with on-site display of measured values and operating data. The device consists of
Type see pump type series two pressure sensors and a display unit. It records the load profile of the pump in
Installation _______ factory- order to indicate any potential for optimising energy efficiency and availability.
_ ________ mounted, IP 65
Applications: For monitoring the operation of a centrifugal pump.
Voltage __________ 24 V DC

Reference no. 4072.5-10

Amacontrol Monitoring system for submersible waste water pumps

Design: Monitoring system for submersible waste water pumps with shutdown.
No. of pumps ______ max. 1
Type _ ___________ Amacan
Installation ______ mounting
_ ____________ plate IP20
Voltage _________ 230 V AC

Reference no. 2316.178-10

53
Subject to technical modification without prior notice.
Your local KSB representative:

More space for solutions.

0506.02/17-10 / 01.11 / © KSB Aktiengesellschaft 2011

KSB Aktiengesellschaft
Johann-Klein-Straße 9
67227 Frankenthal (Germany)
www.ksb.com

Das könnte Ihnen auch gefallen