Product Selector Guide

Generator Protection

Generator Protection Selector Guide


Features

Device

489

P342

P346

889

G30

G60

P343/4/5

P348

APPLICATIONS & FUNCTIONALITY

Small Size Generators


Medium size Generators
Large Size Generators
Low Impedance Grounded generators
High Impedance Grounding generators
Hydro Generators with Split Phase, Stator Winding
Generators with In-Zone Transformer
Variable Speed Double Fed Induction Generators

PROTECTION & CONTROL

Overspeed
Distance Backup
Volts/Hz
Synchronism check
Phase/Auxiliary Undervoltage
Directional Power
Bearing RTD
Loss of Field
Loss of Field using Reactive Power
Generator Unbalance
Voltage phase reversal
Generator Thermal Overload
Transformer Hottest-spot Temperature
Transformer Aging factor
Transformer Loss of Life
Transformer Thru Fault Monitoring
Accidental Energization
IOC Phase/Ground/Neutral
TOC Phase/Ground/Neutral
Time overcurrent - Neutral
Voltage-Dependent Overcurrent (VCO/VRO)
Time overcurrent - Ground
Split Phase
Breaker Failure
Overvoltage - Phase
Overvoltage - Neutral
Overvoltage - Auxiliary
Overvoltage - Negative Sequence
100% Stator Earth Fault (3rd harm. UV)
100% Stator Earth Fault (3rd harmonic diff.)
100% Stator Earth Fault (sub-harmonic volt. Inj.)
Field Ground using low frequency injection
Directional overcurrent - Negative Sequence
Directional overcurrent - Phase
Directional overcurrent - Ground
Directional overcurrent - Neutral
Power Swing Blocking
Out of Step Tripping
Underfrequency
Overfrequency
Rate of Change of Frequency
Frequency Out-Of-Band Accumulator
Lockout
Generator Differential
Generator & Transformer Differential
Restricted Ground Fault
Trip Bus

12
21P
24
25
27P/X
32
38
40
40Q
46
47
49 /49TOL

50/27
50P/G/N
51P/G/N
51N
51V
51G
50SP
50BF
59P
59N
59X
59_2/47
27TN
64TN
64S
64F
67_2
67P
67G
67N
68
78
81U
81O
81R
81A
86
87G
87GT/87O
87G/REF/RGF
TB

P/G
P/G

P/G
P/G

P/G
P/G

Logic

Logic

GEGridSolutions.com

P/X

P/G/N
P/G/N

P/X

Logic

P/G/N
P/G/N

P/X

Logic

P/G/N
P/G/N

P/G
P/G

P
P

P345 only

Logic

Product Selector Guide

Device

489

P342

P346

889

G30

G60

P343/4/5

9
6
4
4
12

24
24
4
4
10

32
32
4
4
10

24
10
4
7
13

64
64

32
32

Logic

Logic

80
70
40
20
40
12
64
96
32
32

32
32
4
4
10

64
64

80
70
40
20
40
12
64
96
32
32

512
24

512
24

1024
128

15ms

1024
64

15ms

1024
64

15ms

P348

AUTOMATION

Contact Inputs (max)


Contact Outputs (max)
Analog Inputs (max)
Analog Outputs (max)
RTD Inputs (max)
RRTD inputs (max)
Virtual Inputs
Virtual Outputs
Direct Inputs
Direct Outputs
Teleprotection Inputs & Outputs
Programmable Logic
FlexElements
Trip-Coil Supervision
User-Programmable LEDs
User-Programmable Pushbuttons
Setting Groups
Selector Switch
Digital Counters
Digital Elements / Limit Values
Redundant Power Supply

64
64

64
64

Logic

Logic

512
24

512
24

MONITORING & METERING

Current
Voltage
Frequency
Power Factor
Power - Real, Reactive, Apparent
Energy
Demand - Current, MW, MVA, Mvar
Temperature
Event Recorder (number of events)
Oscillography / Transient Recorder - Sampling Rate
Fault Reports (user programmable)
Data Logger / Trend Recording
Voltage Transformer Fuse Failure
Current Transformer Supervision

256
12

VTFF/VTS
CTS

5s

COMMUNICATIONS

Front Port Local Access


RS232/RS485 serial communications
IEEE C37.94 fiber interface
Ethernet Communications
Fiber Optic Ethernet
PROTOCOLS

DNP 3.0 Protocol


Courier
EGD (Ethernet Global Data) Protocol
Modbus Protocol
IEC 61870-5-103 protocol
IEC 61870-5-104 protocol
IEC61850 protocol
Peer-to-Peer Communications (GSSE/GOOSE)
CyberSentry Level 1 for cyber security
Synchrophasors (PMU using IEEE C37.118)
IEEE 1588
Parallel Redundancy Protocol - PRP (IEC 62439-3)
High Availability Seamless Redundancy Protocol HSR (IEC 62439-3 Clause 5)
Simple Network Time Protocol (SNTP)
IRIG-B Input
Process Bus (IEC 61850-9-2)

For the most up-to-date selector guides, please visit

GEGridSolutions.com/SelectorGuides

GEGridSolutions.com

Generator Protection

Features Continued