Sie sind auf Seite 1von 14

DEUTSCHE NORM

May 2005

DIN 7080

Supersedes
DIN 7080:1999-05

ICS 71.120.10

Circular borosilicate sight glasses with unlimited pressure resistance at


low temperatures

A&I-Normenabonnement - BASF Aktiengesellschaft GIC-T - Q 920 - Kd.-Nr.1309388 - Abo-Nr.01356984/002/001 - 2008-01-03 09:07:15

Runde Schauglasplatten aus Borosilicatglas fr Druckbeanspruchung ohne Begrenzung


im Tieftemperaturbereich

Document comprises 14 pages

Translation by DIN-Sprachendienst.
In case of doubt, the German-language original should be consulted as the authoritative text.

No part of this translation may be reproduced without prior permission of


DIN Deutsches Institut fr Normung e. V., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany,
has the exclusive right of sale for German Standards (DIN-Normen).

English price group 10


www.din.de
www.beuth.de

!$H7"
1379420

DIN 7080:2005-05

Foreword
This standard has been prepared by Technical Committee FNCA AA 1 Anlagenteile of the Normenausschuss
Chemischer Apparatebau (Process Engineering Standards Committee).
Annexes A and B are informative.
Amendments
This standard differs from DIN 7080:1999-05 as follows:
a)

Subclause 4.5.2 has been corrected in accordance with Corrigendum DIN 7080:1999-05.

b)

Subclause 4.5.4 has been corrected.

c)

Permissible working pressure has been replaced by maximum permissible pressure.

d)

The standard has been editorially revised.

Previous editions

A&I-Normenabonnement - BASF Aktiengesellschaft GIC-T - Q 920 - Kd.-Nr.1309388 - Abo-Nr.01356984/002/001 - 2008-01-03 09:07:15

DIN 7080: 1943x-10, 1965-07, 1975-09, 1996-02, 1999-05

Scope

This standard applies to thermally prestressed circular borosilicate sight glasses that can be continuously
subjected on one side to liquid or gas pressures at up to 280 C and, in exceptional circumstances, to 300 C
(cf. subclause 4.3.2). The sight glasses can only be used at pressures and temperatures up to those specified
if they are installed as described in clause 10. There is no limit on the use of sight glasses conforming to this
standard at temperatures below ambient temperature.

Normative references

The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
DIN 28120, Circular sight glasses with case in main power connection
DIN 28121, Circular sight glasses with case in metal to metal contact type flanged joint
DIN ISO 695, Glass Resistance to attack by a boiling aqueous solution of mixed alkali Method of test
and classification
DIN ISO 718, Laboratory glassware Thermal shock and thermal shock endurance Test methods
DIN ISO 719, Glass Hydrolytic resistance of glass grains at 98 C Method of test and classification
DIN ISO 1776, Glass Resistance to attack by hydrochloric acid at 100 C Flame emission or flame
atomic absorption spectrometric method
DIN ISO 2859-1, Sampling procedures for inspection by attributes Part 1: Sampling schemes indexed by
acceptance quality limit (AQL) for lot-by-lot inspection
DIN ISO 7991, Glass Determination of coefficient of mean linear thermal expansion

DIN 7080:2005-05

Dimensions and designation


Dimensions in millimetres

Key
1
a

Seal
Chamfered edge (cf. Table 1)
Figure 1 Sight glass

Designation of a circular sight glass having a diameter, d1, of 100 mm and a thickness, s, of 15 mm:

A&I-Normenabonnement - BASF Aktiengesellschaft GIC-T - Q 920 - Kd.-Nr.1309388 - Abo-Nr.01356984/002/001 - 2008-01-03 09:07:15

Sight glass DIN 7080 100 15


The relationship between maximum permissible pressure and dimensions is shown in Table 1.
Table 1 Dimensions
Maximum permissible pressure, in bar
Diameter
d1
45
(50)
(60)
63
80
100
125
150
175
200
250
135
265

Diameter
d2

10

16

25

40

50

10
12
15
15
20
25

12

Thickness
s

32

35

10
45

10
12
48

10
12
65

12
15
80

15
20
100

15
20
25
125

20
25
30
a
150

20
30a
25
25
30

175
20a
a
30

225
25
Only applicable to containers made of enamelled steel
110

25
240
30

Diameters in brackets are not for use in new designs.


a

The safety factor for these sizes is between 4,5 and 4,9.

DIN 7080:2005-05

Material

4.1

General

The material used shall be thermally prestressed borosilicate glass conforming to the requirements specified
in subclauses 4.2 to 4.5.

4.2

Mechanical strength

Unprestressed glass having a (tested) flexural tensile strength of about 40 N/mm2 shall be thermally
prestressed until the compressive prestress at the surface is not less than 100 N/mm2 (see Annex A.1).

4.3
4.3.1

Thermal properties
Mean coefficient of linear thermal expansion

The mean coefficient of linear thermal expansion, (20 C, 300 C), determined as specified in DIN ISO 7991
shall not exceed 5,0 106 K1.
4.3.2

Permissible working temperature

A&I-Normenabonnement - BASF Aktiengesellschaft GIC-T - Q 920 - Kd.-Nr.1309388 - Abo-Nr.01356984/002/001 - 2008-01-03 09:07:15

The continuous working temperature of the sight glass shall normally not exceed 280 C.
It should be borne in mind that, at temperatures above 280 C, a permanent decrease in the prestress is likely
to occur (see Annex B [1]). For example, at a working temperature of 300 C, the prestress will probably be
only 90 % of the initial value after the sight glass has been in service for 300 hours.
However, use at temperatures between 280 C and 300 C is permissible provided suitable precautions are
taken, such as
protecting the sight glass with mica and
restricting the cumulative working time above 280 C to a maximum of 300 hours.
4.3.3

Thermal shock resistance

The thermal shock resistance of the sight glass determined as specified in DIN ISO 718 and subclause 7.4
shall be 230 C.

4.4

Chemical resistance

The chemical resistance of borosilicate glass shall comply with the following:
hydrolytic resistance class HBG 1 as in DIN ISO 719;
acid resistance class as in DIN ISO 1776 not exceeding 100 g Na2O/100 cm2 ;
alkali resistance class A2 as in DIN ISO 695 (see also Annex A.2).

DIN 7080:2005-05

4.5

Material defects

4.5.1

General

Bubbles, striations, bands of striations, viscous knots and crystalline inclusions shall not exceed the values
given below and shall not affect the mechanical strength or have a technically significant effect on
transparency (see Annex B, [2]).
4.5.2

Bubbles

The diameter of spherical bubbles in the glass and the average of the length and width of oval ones shall not
exceed 2 mm. Tapered bubbles are not permitted.
The number of bubbles in a given size range shall be within the limits specified in Table 2.
Table 2 Permissible number of bubbles
Bubble diameter,
d3

A&I-Normenabonnement - BASF Aktiengesellschaft GIC-T - Q 920 - Kd.-Nr.1309388 - Abo-Nr.01356984/002/001 - 2008-01-03 09:07:15

d3 < 0,3

4.5.3

Permissible number of bubbles


3 per cm2 of sight glass

0,3 d3 0,5

10 per sight glass

0,5 < d3 1

4 per sight glass

1 < d3 2

2 per sight glass

Viscous knots, striations and bands of striations

There shall be no viscous knots, sharp striation or bands of striations that are visible to the naked eye.
4.5.4

Crystalline inclusions

The diameter of any inclusions in the glass shall not exceed 0,2 mm, there shall not be more than three
inclusions per sight glass and the distance between them shall not be less than 10 mm.

Finish

The sight glass shall be thermally prestressed (see subclause 4.2 and Annex A.1), its surfaces shall be
ground and polished and, at the manufacturers discretion, its rim shall be cold-pressed and/or ground and its
edges chamfered by pressing or by rubbing down.
For manufacturing reasons, the rim may be inclined at 1,5, with d1 being taken as the largest external
diameter.

DIN 7080:2005-05

Geometrical tolerances

Figure 2 gives the notation for the dimensions referred to in the tables below.

Key
a
b

Edge dimension (see Table 5)


Pressure side
Figure 2 Shape tolerances, positional tolerances and edge tolerances

A&I-Normenabonnement - BASF Aktiengesellschaft GIC-T - Q 920 - Kd.-Nr.1309388 - Abo-Nr.01356984/002/001 - 2008-01-03 09:07:15

6.1

Limit deviations

Table 3 shows the allowable tolerances in the diameter and thickness of a sight glass.
Table 3 Limit deviations
Dimensions in millimetres
Diameter d1

6.2

Thickness s

d1 135

150 d1 200

d1 > 200

10 s 20

s > 20

0,5

0,8

+ 0,5
0,25

+ 0,8
0,4

Shape tolerances and positional tolerances

The maximum allowable deviations of the faces from flatness and parallelism are shown in Table 4.
Table 4 Flatness and parallelism
Dimensions in millimetres
d1 100

100 < d1 150

150 < d1 200

d1 > 200

Flatness e

0,05

0,08

0,12

0,15

Parallelism p

0,2

Diameter d1

0,25

0,3

DIN 7080:2005-05

6.3

Edge tolerances

The edge finishes resulting from the chamfer are shown in Table 5.
Table 5 Edge tolerances
Dimensions in millimetres

7
7.1

Diameter d1

Edge dimensions

100

1,0
0,3

> 100

1,5
0,3

Testing
General

A&I-Normenabonnement - BASF Aktiengesellschaft GIC-T - Q 920 - Kd.-Nr.1309388 - Abo-Nr.01356984/002/001 - 2008-01-03 09:07:15

The manufacturer shall test the sight glass for conformity with the specifications given in clauses 3, 4, 5 and 6
and shall confirm that the requirements have been fulfilled by marking the sight glass as specified in clause 8.

7.2

Qualitative prestress assessment by photoelastic analysis

Every sight glass shall be tested by viewing it perpendicularly to the flat glass surface. Several clearly
distinguishable circular lines closed upon themselves (isochromatics) shall be visible at the rim (see Figure 3).
The line pattern described indicates the presence of compressive prestress.

Figure 3 Sight glass viewed in polarized light

7.3

Quantitative prestress assessment by random burst pressure tests

Depending on batch size, random sample tests shall be performed on every (prestressed) batch produced in
accordance with the following scheme.

DIN 7080:2005-05

Number of samples
Batches of less than 20:

1 sample

Batches of 20 to 50:

2 samples

Batches of more than 50:

3 samples

Procedure

A&I-Normenabonnement - BASF Aktiengesellschaft GIC-T - Q 920 - Kd.-Nr.1309388 - Abo-Nr.01356984/002/001 - 2008-01-03 09:07:15

Samples shall be taken from every prestressed batch of finished sight glasses in accordance with the above
scheme.

Key
1
a
b

Plastic ring
Ground
Pressure side
Figure 4 Testing device

Before testing, one of the two flat sides of the sight glass shall be spoilt beforehand by grinding a central
circular area having a diameter of 0,5 d1 in all directions with a circular movement using wet grade 220 emery
paper. In doing this, it is important to avoid anomalous individual scratches by drawing off the wet emery
paper over a metal edge. To prevent a wide variation in the burst test measurements, it is advisable to work
with emery paper from a single batch.
After being spoilt, the sight glasses shall be burst-tested with cold water in the device shown in Figure 4, with
the side spoilt by grinding facing away from the water. The latter should have film glued to it beforehand to
prevent injury due to splintering.
The bursting pressure, pBG (the pressure at which the sight glass shatters), in bar, shall be measured and
used to determine the bursting stress, BG, in N/mm2, for every thermally stressed sight glass using equation
(1):

BG =

pBG C d m

10
s

(1)

Every sample shall fulfil equation (2):


BG BU = DV 100 N/mm2

(2)

DIN 7080:2005-05

where in equations (1) and (2)


BU

is the bursting stress of sight glasses that have not been thermally prestressed (i.e. are stressrelieved), in N/mm2;

DV

is the compressive prestress determined by a bursting test, in N/mm2;

pBU

is the pressure at which the sight glass shatters that have not been thermally prestressed (i.e. are
stress-relieved), in bar;

is a calculation coefficient (here, 0,55);

dm

is the mean seal diameter, in mm, calculated using equation (3):


d + d2
dm = 1
;
2

is the thickness as in Table 1, in mm.

dm and s are to be substituted in equation (1).

A&I-Normenabonnement - BASF Aktiengesellschaft GIC-T - Q 920 - Kd.-Nr.1309388 - Abo-Nr.01356984/002/001 - 2008-01-03 09:07:15

The value of BU in equation (2) shall be determined in the same way by burst-testing sight glasses that have
been stress-relieved by heating and slowly cooling. It can be taken as the mean of current operating tests, but
no test value shall be more than six months old. The value of BU substituted in equation (2) shall not be less
than 35 N/mm2.

7.4

Thermal shock test

Random samples shall be taken from every prestressed batch in accordance with the sampling scheme in
subclause 7.3, heated to 250 C and completely immersed in flowing water at 20 C for at least one minute.
The failure criterion shall be complete shattering.

7.5

Tolerance checking

Tolerance checks shall be performed on random samples taken from every prestressed batch. The single
sampling plans for normal inspection in accordance with DIN ISO 2859-1 test level I apply to each attribute
(diameter, thickness, flatness, parallelism and edge tolerances), the acceptance quality limit (AQL) being 10.
All the attributes may be tested on a single test piece.

7.6

Test report

For every prestressed batch, the manufacturer shall document the results of the tests specified in subclauses
7.2 to 7.5 and, if requested to do so by the client, make them available for inspection. The test report shall
include the following details:
a)

prestressed batch marking;

b)

the values of BU, BG and BG BU;

c)

confirmation that a photoelastic test has been performed on every sight glass in the batch;

d)

thermal shock test result;

e)

confirmation that every sight glass has passed the visual test for material defects;

f)

dimensional test results.

DIN 7080:2005-05

Marking

The following permanent markings shall appear in the area shown in Figure 5 on the smaller face, i.e. the one
remote from the pressure, of every sight glass with the dimensions shown in Table 6:
DIN 7080;
the numerical value of the permissible pressure as specified in Table 1, in bar.
The following shall be marked on the cylindrical glass rim:
the manufacturers logo or trademark;
the prestressed batch mark in such a way as to permit clear traceability of the documented test results.

A&I-Normenabonnement - BASF Aktiengesellschaft GIC-T - Q 920 - Kd.-Nr.1309388 - Abo-Nr.01356984/002/001 - 2008-01-03 09:07:15

The manufacturers logo or trademark (e.g. XYZ) can appear in the area shown in Figure 5 with the
dimensions shown in Table 6.

Figure 5 Marking areas

Packaging

The packaging design may be freely chosen by the manufacturer provided that every sight glass is protected
against impact and scratches during transportation, including interdepartmental transportation, and storage at
the clients premises.

10 Installation and safety requirements


The maximum permissible pressures shown in Table 1 will only be attained if the sight glasses are installed in
such a way that internal plant pressure is applied to the larger face and the sight glasses are uniformly
clamped using sight glass fittings with the dimensions, seals and numbers and sizes of screws specified in
DIN 28120 or DIN 28121 if sealing takes place on the flat glass faces. Other fittings may be used if their
suitability is demonstrated.
Sight glasses shall be fitted only by personnel who have been given detailed instructions on the following:
how to handle sight glasses with care;

10

DIN 7080:2005-05

how to clean the fittings, sight glasses, seals and shims, i.e. remove foreign bodies, such as splinters,
from them, before installation;
how to tighten up the fixing screws uniformly.
Sight glasses removed after being in service shall not be reused.
Table 6 Marking dimensions

Dimensions in millimetres
Diameter
d1

45

6,5

2,5

12

(50)
(60)
63

10

80
100

12

A&I-Normenabonnement - BASF Aktiengesellschaft GIC-T - Q 920 - Kd.-Nr.1309388 - Abo-Nr.01356984/002/001 - 2008-01-03 09:07:15

125
135
150
175

15

200
250
265

11

DIN 7080:2005-05

Annex A
(informative)
Explanatory notes

A.1 Mechanical strength


The simultaneous exposure of circular sight glasses to severe thermal, mechanical and chemical conditions
necessitates the use of heat-resistant borosilicate glasses having high mechanical strength and also the
highest possible resistance to chemical attack. Such glasses can withstand the liquid or gas pressure acting
on one side, the clamping forces and the thermal stresses resulting from temperature differences only if their
normal tensile strength is increased by thermal prestressing. The crucial quality criterion is that the
compressive surface stress produced by prestressing is not less than 100 N/mm2, thereby increasing the
normal flexural tensile strength of about 40 N/mm2 by a factor of at least 2,5. It is essential that no tensile
stresses occur after installation. The level of the surface stress resulting from the liquid or gas pressure acting
on one side will then remain below the value of the compressive prestresses.

A&I-Normenabonnement - BASF Aktiengesellschaft GIC-T - Q 920 - Kd.-Nr.1309388 - Abo-Nr.01356984/002/001 - 2008-01-03 09:07:15

Assuming a minimum value of the compressive prestress, DVzul, of 100 N/mm2 and a safety factor, S, of 5,
the thicknesses were calculated so as to fulfil the following inequality:
s C dm

pS
10 DV zul

(A.1)

where p is the maximum permissible pressure, in bar.


As the flexural tensile strength increases, the prestressing also results in an increase in the thermal shock
resistance, the value of the latter being primarily determined, for a given temperature gradient, not only by the
elastic properties, but also by the heat conduction and the coefficient of expansion.
The safety of sight glasses when under pressure is crucially dependent on the design of components used to
fit them and the installation procedure.
The safety factor, S, of 5 will apply only if the manufacturers installation and operating guidelines are adhered
to.

A.2 Chemical resistance


The extent to which glass in boiler sight glasses is attacked when exposed to aqueous media will normally
increase exponentially as the temperature and pH of the medium rises and the attack may be considerably
accelerated by chemical additives such as those used in various ways and amounts in water treatment plants.
The resultant severe erosion and consequential dimensional changes may endanger the working safety of the
sight glass and may result in rupture. The most important influencing variables are, however, the pH and
temperature, but, for other complex reasons, the temperature plays a major role at temperatures markedly
above 200 C. To illustrate this, the figure below shows the erosion of a glass surface at 170 C for two
different pH levels, while the broken line shows the effect of increasing the temperature to 220 C at a pH of
10 under laboratory conditions.

12

A&I-Normenabonnement - BASF Aktiengesellschaft GIC-T - Q 920 - Kd.-Nr.1309388 - Abo-Nr.01356984/002/001 - 2008-01-03 09:07:15

DIN 7080:2005-05

Figure A.1 Sight glass erosion

13

DIN 7080:2005-05

Annex B
(informative)

A&I-Normenabonnement - BASF Aktiengesellschaft GIC-T - Q 920 - Kd.-Nr.1309388 - Abo-Nr.01356984/002/001 - 2008-01-03 09:07:15

Bibliography

[1]

DIN ISO 13715, Technical drawings Edges of undefined shape Vocabulary and indication on
drawings

[2]

DIN ISO 1101, Technical drawings Geometrical tolerancing Tolerancing of form, orientation,
location and run-out Generalities, definitions, symbols, indications on drawings (withdrawn June
2005, superseded by DIN EN ISO 1101:2005-06)

[3]

DIN EN ISO 1302, Technical drawings Method of indicating surface texture (identical with
ISO 1302:1992) (withdrawn June 2002, superseded by DIN EN ISO 1302:2002-06)

[4]

Novotny, V. and Kavka, I. Stress relaxation in toughened glass. Glass Technology, 1977: 18, No. 5.

[5]

Jebsen-Marwedel, H. and Brckner, R. Glastechnische Fabrikationsfehler (Glass manufacturing


defects), Berlin, Heidelberg, New York: Springer Verlag, 1980.

14