Beruflich Dokumente
Kultur Dokumente
NOTICE
Do not install indoor units in areas (e.g. mobile phone base stations) where the emission of VOCs such as phthalate
compounds and formaldehyde is known to be high as this may result in a chemical reaction.
Our air-conditioning equipment and heat pumps contain a fluorinated greenhouse gas, R410A.
When installing or relocating or servicing our air-conditioning equipment, use only the specified refrigerant (R410A) to charge
the refrigerant lines.
Do not mix it with any other refrigerant and do not allow air to remain in the lines.
If air is mixed with the refrigerant, then it can be the cause of abnormal high pressure in the refrigerant lines, and may result
in an explosion and other hazards.
The use of any refrigerant other than that specified for the system will cause mechanical failure, system malfunction or unit
breakdown. In the worst case, this could lead to a serious impediment to securing product safety.
2016
1kW
Electrical
Energy Input
80oC
10oC
Compressor compresses
refrigerant to raise
the temperature
Compressor
20 C
60 C
Indoors
Outdoors
4kW
4kW
Heat absorbed
from the air
Evaporator
Condenser
Heat output
Expansion valve
o
40 C
30 C
5oC
50oC
Heat
Ecology
1. Inverter
2. 3D i-see Sensor
3. Flash Injection
power generation
ONTENTS
Air Conditioners
LINE-UP
005-008
009-010
INVERTER TECHNOLOGIES
011-012
FEATURES
013-020
FUNCTION LIST
021-024
CONTROL TECHNOLOGIES
027-032
M SERIES
033-054
SERIES
055-062
SERIES
063-088
089-098
099-104
OPTIONAL PARTS
117-122
EXTERNAL DIMENSIONS
123-138
PIPING INSTALLATION
139-144
AIR-TO-WATER
145-162
LOSSNAY SYSTEM
163-174
LINE-UP
M SERIES
INVERTER Models
Model Name
1.5kW
1.8kW
2.0kW
2.2kW
2.5kW
3.5kW
4.2kW
5.0kW
6.0kW
7.1kW
1-phase
1-phase
1-phase
1-phase
1-phase
1-phase
1-phase
1-phase
1-phase
1-phase
SINGLE
SINGLE
Page
MSZ-F Series
MSZ-E Series
SB
MXZ
connection
only
SINGLE
35
SB
MXZ
connection
only
MSZ-S Series
MXZ
connection
only
SINGLE
SB
H
SINGLE
SB
H
SINGLE
SB
SINGLE
SB
39
MXZ
connection
only
41
Wallmounted
SINGLE
SINGLE
SINGLE
SINGLE
41
MSZ-G Series
SINGLE
SINGLE
41
MSZ-D Series
MSZ-H Series
SINGLE
SINGLE
SINGLE
SINGLE
SINGLE
SINGLE
SINGLE
SINGLE
49
MXZ
connection
only
MXZ
connection
only
MXZ
connection
only
51
45
MSZ-HJ60/71
SINGLE
SINGLE
47
MSZ-HJ25/35/50
MFZ Series
Compact
floor
MLZ Series
1-way
cassette
S SERIES
INVERTER Models
Model Name
2.5kW
3.5kW
4.2kW
5.0kW
6.0kW
7.1kW
8.0kW
1-phase
1-phase
1-phase
1-phase
1-phase
1-phase
1-phase
SINGLE
SINGLE
SINGLE
SINGLE
10.0kW
14.0kW
20.0kW
Page
SLZ Series
2x2
cassette
Compact
ceilingconcealed
57
SEZ Series
SINGLE
SINGLE
SINGLE
SINGLE
SINGLE
61
L : Indoor units are available in two types; with or without the wireless remote controller.
Indoor Combinations
SINGLE 1 outdoor unit & 1 indoor unit
TWIN 1 outdoor unit & 2 indoor units
TRIPLE 1 outdoor unit & 3 indoor units
QUADRUPLE 1 outdoor unit & 4 indoor units
MXZ SERIES
INVERTER Models
Model Name
up to 6 indoor units
MXZ-6D122VA
up to 5 indoor units
MXZ-5E102VA
up to 4 indoor units
MXZ-4E83VA
up to 4 indoor units
MXZ-4E72VA
up to 3 indoor units
MXZ-3E68VA
up to 3 indoor units
MXZ-3E54VA
up to 2 indoor units
MXZ-2D53VA (H)2
up to 2 indoor units
MXZ-2D42VA2
up to 2 indoor units
MXZ-2D33VA
up to 3 indoor units
MXZ-3DM50VA
up to 2 indoor units
MXZ-2DM40VA
up to 4 indoor units
MXZ-4E83VAHZ
up to 2 indoor units
MXZ-2E53VAHZ
Ceiling-concealed
Ceiling-suspended
Page
MLZ-KA25/35/50
SLZ-KF25/35/50
PLA-RP50/60/71
SEZ-KD25/35/50/60/71
PEAD-RP50/60/71
PCA-RP50/60/71
91
MFZ-KJ25/35/50
MLZ-KA25/35/50
SLZ-KF25/35/50
PLA-RP50/60/71
SEZ-KD25/35/50/60/71
PEAD-RP50/60/71
PCA-RP50/60/71
91
MFZ-KJ25/35/50
MLZ-KA25/35/50
SLZ-KF25/35/50
PLA-RP50/60/71
SEZ-KD25/35/50/60/71
PEAD-RP50/60/71
PCA-RP50/60/71
91
MFZ-KJ25/35/50
MLZ-KA25/35/50
SLZ-KF25/35/50
PLA-RP50/60
SEZ-KD25/35/50/60
PEAD-RP60
PCA-RP50/60
91
MFZ-KJ25/35/50
MLZ-KA25/35/50
SLZ-KF25/35/50
PLA-RP50/60
SEZ-KD25/35/50/60
PEAD-RP60
PCA-RP50/60
91
PCA-RP50
91
Capacity Class
Wall-mounted
Floor-standing
12.2kW
<1-phase>
MSZ-FH25/35/50
MSZ-EF18/22/25/35/42/50
MSZ-SF15/20/25/35/42/50
MSZ-GF60/71
MFZ-KJ25/35/50
10.2kW
<1-phase>
8.3kW
<1-phase>
7.2kW
<1-phase>
6.8kW
<1-phase>
MSZ-FH25/35/50
MSZ-EF18/22/25/35/42/50
MSZ-SF15/20/25/35/42/50
MSZ-GF60/71
MSZ-FH25/35/50
MSZ-EF18/22/25/35/42/50
MSZ-SF15/20/25/35/42/50
MSZ-GF60/71
MSZ-FH25/35/50
MSZ-EF18/22/25/35/42/50
MSZ-SF15/20/25/35/42/50
MSZ-GF60
MSZ-FH25/35/50
MSZ-EF18/22/25/35/42/50
MSZ-SF15/20/25/35/42/50
MSZ-GF60
Cassette
5.4kW
<1-phase>
MSZ-FH25/35/50
MSZ-EF18/22/25/35/42/50
MSZ-SF15/20/25/35/42/50
MFZ-KJ25/35/50
MLZ-KA25/35/50
SLZ-KF25/35/50
PLA-RP50
SEZ-KD25/35/50
PEAD-RP50
5.3kW
<1-phase>
MSZ-FH25/35
MSZ-EF18/22/25/35/42/50
MSZ-SF15/20/25/35/42/50
MFZ-KJ25/35
MLZ-KA25/35
SLZ-KF25/35
SEZ-KD25/35
91
4.2kW
<1-phase>
MSZ-FH25/35
MSZ-EF18/22/25/35
MSZ-SF15/20/25/35
MFZ-KJ25/35
MLZ-KA25/35
SLZ-KF25/35
SEZ-KD25/35
91
3.3kW
<1-phase>
MSZ-FH25
MSZ-EF18/22/25
MSZ-SF15/20/25
MFZ-KJ25
MLZ-KA25
SLZ-KF25
SEZ-KD25
91
5.0kW
<1-phase>
MSZ-HJ25/35/50
MSZ-DM25/35
93
4.0kW
<1-phase>
MSZ-HJ25/35
MSZ-DM25/35
93
8.3kW
<1-phase>
MSZ-FH25/35/50
MSZ-EF18/22/25/35/42/50
MSZ-SF15/20/25/35/42/50
MSZ-GF60/71
MFZ-KJ25/35/50
MLZ-KA25/35/50
SLZ-KF25/35/50
PLA-RP50/60/71
SEZ-KD25/35/50/60/71
PEAD-RP50/60/71
5.3kW
<1-phase>
MSZ-FH25/35
MSZ-EF18/22/25/35/42/50
MSZ-SF15/20/25/35/42/50
MFZ-KJ25/35
MLZ-KA25/35
SLZ-KF25/35
SEZ-KD25/35
PCA-RP50/60/71
113
113
2.5kW
3.5kW
5.0kW
5.3kW
7.1kW
8.3kW
10.0kW
12.5kW
1-phase
1-phase
1-phase
1-phase
1-phase
1-phase
1- & 3-phase
3-phase
SINGLE
SINGLE
TWIN
TWIN
PLA Series
4-way cassette
ZUBADAN
PKA Series
SINGLE
Wall-mounted
PEAD-JA Series
101/107
101/109
TWIN
Ceiling-concealed
Page
SINGLE
SINGLE
TWIN
TWIN
101/110
SINGLE
Wall-mounted
SINGLE
SINGLE
103/111
SINGLE
Compact floor
SINGLE
SINGLE
112
2PORT
4PORT
105/114
LINE-UP
P SERIES
POWER INVERTER Models
Model Name
3.5kW
5.0kW
6.0kW
7.1kW
1-phase
1-phase
1-phase
1-phase
SINGLE
SINGLE
SINGLE
SINGLE
SINGLE
SINGLE
SINGLE
SINGLE
SINGLE
SINGLE
SINGLE
SINGLE
PLA Series
4-way cassette
PEAD-JA Series
Ceiling-concealed
TWIN
SINGLE
TWIN
PEA Series
PKA Series
Wall-mounted
PCA-KAQ Series
Ceiling-suspended
Ceiling-suspended
SINGLE
SINGLE
TWIN
SINGLE
TWIN
PCA-HAQ Series
SINGLE
PSA Series
SINGLE
Floor-standing
3.5kW
5.0kW
6.0kW
7.1kW
1-phase
1-phase
1-phase
1-phase
SINGLE
SINGLE
SINGLE
SINGLE
SINGLE
SINGLE
SINGLE
SINGLE
SINGLE
SINGLE
SINGLE
SINGLE
PLA Series
4-way cassette
PEAD-JA Series
Ceiling-concealed
PEA Series
PKA Series
Wall-mounted
PCA-KAQ Series
Ceiling-suspended
Ceiling-suspended
PCA-HAQ Series
PSA Series
Floor-standing
Indoor Combinations
SINGLE 1 outdoor unit & 1 indoor unit
TWIN 1 outdoor unit & 2 indoor units
TRIPLE 1 outdoor unit & 3 indoor units
QUADRUPLE 1 outdoor unit & 4 indoor units
10.0kW
12.5kW
14.0kW
20.0kW
25.0kW
40.0kW
50.0kW
1- & 3-phase
1- & 3-phase
1- & 3-phase
3-phase
3-phase
3-phase
3-phase
SINGLE
SINGLE
SINGLE
TWIN
TWIN
TWIN
TRIPLE
TWIN
TRIPLE
QUADRUPLE
QUADRUPLE
SINGLE
SINGLE
TWIN
TWIN
TWIN
TRIPLE
TWIN
TRIPLE
QUADRUPLE
QUADRUPLE
SINGLE
SINGLE
SINGLE
TWIN
TWIN
SINGLE
SINGLE
TWIN
TWIN
TWIN
TRIPLE
SINGLE
TWIN
TRIPLE
TWIN
TRIPLE
SINGLE
TWIN
TRIPLE
TWIN
TRIPLE
QUADRUPLE
SINGLE
SINGLE
SINGLE
TWIN
QUADRUPLE
QUADRUPLE
TWIN
73
SINGLE
SINGLE
TRIPLE
TWIN
TRIPLE
TWIN
67
76
78
QUADRUPLE
TWIN
TRIPLE
Page
81
TRIPLE
82
TWIN
TRIPLE
86
10.0kW
12.5kW
14.0kW
20.0kW
25.0kW
40.0kW
50.0kW
1- & 3-phase
1- & 3-phase
1- & 3-phase
3-phase
3-phase
3-phase
3-phase
SINGLE
SINGLE
SINGLE
TWIN
TWIN
TWIN
TRIPLE
TWIN
TRIPLE
QUADRUPLE
QUADRUPLE
SINGLE
SINGLE
TWIN
TWIN
TWIN
TRIPLE
TWIN
TRIPLE
QUADRUPLE
QUADRUPLE
SINGLE
SINGLE
SINGLE
TWIN
TWIN
SINGLE
SINGLE
TWIN
TWIN
TWIN
TRIPLE
SINGLE
TWIN
TRIPLE
TWIN
TRIPLE
SINGLE
TWIN
TRIPLE
TWIN
TRIPLE
QUADRUPLE
TWIN
TRIPLE
TWIN
TRIPLE
QUADRUPLE
QUADRUPLE
TWIN
SINGLE
SINGLE
SINGLE
TWIN
TRIPLE
QUADRUPLE
TWIN
Page
67
73
SINGLE
SINGLE
76
78
81
TRIPLE
82
TWIN
TRIPLE
86
A +++
A ++
A+
A
B
C
D
> 5,1
> 4,6
> 4,0
> 3,4
> 3,1
> 2,8
< 2,5
Helsinki
Strasbourg
Strasbourg also
serves as basis for
calculating the SEER.
II
A +++
A ++
A+
A
B
C
D
> 8,5
> 6,1
> 5,6
> 5,1
> 4,6
> 4,1
< 3,6
Energy efficiency class
Energy efficiency class of the
unit in cooling and heating
mode of the unit model
Athens
XY,Z
X,Y
XY
Indoor unit
60dB(A)
Cooling capacity
> 6 kW 12 kW
60dB(A)
XY,Z
X,Y
XY
XY,Z
X,Y
XY
ZY
XYZ/2012
Outdoor unit
70dB(A)
Time reference
Indication on label data
Climate zones
For heating mode, the EU is divided into three climate zones for
calculation and classification purposes. This aims at calculating
the energy efficiency taking into consideration the actual regional
ambient temperatures.
Warm (Athens)
Temperature conditions
Outdoors
DB
WB
1C
2C
6C
7C
11C
12C
Indoors
DB
20C
20C
20C
20C
Moderate (Strasbourg)
Temperature conditions
Outdoors
Partial
load
DB
WB
8C
88%
7C
1C
54%
2C
6C
35%
7C
11C
15%
12C
Indoors
DB
20C
20C
20C
20C
Partial
load
100%
64%
29%
ZY
Cooling capacity
6 kW
XY,Z
X,Y
XY
Cold (Helsinki)
Partial
load
61%
37%
24%
11%
Temperature conditions
Outdoors
DB
WB
8C
7C
1C
2C
6C
7C
11C
12C
Indoors
DB
20C
20C
20C
20C
SEER/SCOP
Air conditioning systems were previously assessed using the energy-efficiency rating (EER), which evaluated efficiency in cooling mode, and the
coefficient of performance (COP), which defined the efficiency, or the ratio of consumed and output power, in heating mode. Under this system,
assessments were not truly reflective of performance as they were based on a single measurement point, which led to manufacturers optimising
products accordingly in order to achieve higher efficiency ratings. SEER and SCOP address this problem by including seasonal variation in the
ratings via use of realistic measurement points. For cooling mode, measurements at outside temperatures of 20, 25, 30 and 35C are incorporated
and weighted in accordance with climate data for Strasbourg, which is used as a single reference point for the whole EU. For instance, for
partial-load operation, which represents more than 90% of operation, there is a correspondingly high weighting for the efficiency classification. For
heating mode, a comprehensive temperature profile for the whole EU was not possible, so the EU has been divided into three climate zones,
north, central and south, and load profiles created. The same measurement points, at outside temperatures of 12, 7, 2 and 7C, are used for all
three zones.
SCOP Calculation
P design H
T bivalent
Heating capacity at
nominal frequency
SCOP calculation in
the heat pump mode
If T bivalent is high
P design H = high
SCOP = low
-10C
-7C
-2C
16C
Outside
temperature
10
INVERTER TECHNOLOGIES
Mitsubishi Electric inverters ensure superior performance including the optimum control of operation frequency. As a result,
optimum power is applied in all heating/cooling ranges and maximum comfort is achieved while consuming minimal energy.
Fast, comfortable operation and amazingly low running cost Thats the Mitsubishi Electric promise.
ECONOMIC OPERATION
Impressively low operating cost is a key advantage of inverter air conditioners. Weve combined advanced inverter technologies with cutting-edge
electronics and mechanical technologies to achieve a synergistic effect that enables improvements in heating/cooling performance efficiency.
Better performance and lower energy consumption are the result.
TRUE COMFORT
Simple comparison of air conditioner operation control with and without inverter.
Inverter Operation Image (cooling mode)
Cooling capacity (W)
Temperature (C)
Point 1
When room temperature is higher than the
setting, capacity rises for the quickly adjust-
Rated capacity
Setting temperature
Indoor temperature
Point 2
Measured capacity
Point 1
Point 2
KEY TECHNOLOGIES
11
Inverter size has been reduced using insertmolding, where the circuit pattern is molded into
the synthetic resin. To ensure quiet operation,
soft PWM control is used to prevent the metallic
whine associated with conventional inverters.
Supply
voltage
DC compressor
motor ( rotor )
Neodymium
magnets
Time
Current
Time
PAM adjusts the form of the current wave so that it becomes close to that of the supply
voltage wave. High harmonics are reduced and 98% of the electricity is utilized.
Magnetic torque
Reluctance torque
Fixed scroll
Frame can
move in direction
of axis
PAM
Conventional
inverter
Limited power
Insufficient power
when needed
Substantial
reduction in leakage
and friction loss
Heat Caulking
Fixing Method
Power increased
Efficient voltage increase
realises increased power
Cradle scroll
Heat
exchanger
Power
receiver
LEV1
Grooved Piping
DC Fan Motor
A highly efficient DC motor drives the fan of the outdoor unit.
Efficiency is much higher than an equivalent AC motor.
Compressor
Heat
exchanger
LEV2
Grooved piping
Pipe image
12
FUNCTIONS (1 )
i-see Sensor
for M SERIES
The FH Series is equipped with 3D i-see Sensor, an infrared-ray
sensor that measures the temperature at distant positions. While
moving to the left and right, eight vertically arranged sensor
elements analyze the room temperature in three dimensions. This
detailed analysis makes it possible to judge where people are
in the room, thus allowing creation of features such as Indirect
airflow, to avoid airflow hitting people directly, and direct airflow
to deliver airflow to where people are.
Indirect Airflow
Direct Airflow
Sensor with
eight elements
Absence Detection
The sensors detect whether there are people in the room. When no-one is in the room,
the unit automatically switches to energy-saving mode.
8 94 areas
Sensor measures while
moving to the left to right
Divided into 94
(Image)
The 3D i-see Sensor detects peoples absence and the power consumption is automatically
reduced approximately 10% after 10 minutes and 20% after 60 minutes.
for S SERIES
Detects number of people
The 3D i-see Sensor detects the number of people in the room and
adjusts the power accordingly. This makes automatic power-saving
operation possible in places where the number of people changes
frequently. Additionally, when the area is continuously unoccupied,
the system switches to a more enhanced power-saving mode. Depending on the setting, it can also stop the operation.
Detects number
of people
Detects peoples
position
Detects position
and number of people
360
Detection
Detects floor
temperature
8 sensors
2.7m
7.2m
1.1m
12m
53
Floor surface
13
1C
power
savings
No occupancy energy save mode
2C
power
savings
No occupancy Auto-Off mode
Auto-Off
Seasonal airflow*
When cooling
Saves energy while keeping a comfortable effective temperature by automatically switching between ventilation and
cooling. When a pre-set temperature
is reached, the air conditioning unit
switches to swing fan operation to
maintain the effective temperature.
This clever function contributes to
keeping a comfortable coolness.
When heating
The air conditioning unit automatically
switches between circulator and heating.
Wasted heat that accumulates near the
ceiling is reused via circulation. When a
pre-set temperature is reached the air conditioner switches from heating to circulator
and blows air in the horizontal direction. It
pushes down the warm air that has gathered near the ceiling to peoples height,
thereby providing smart heating.
Cooling
Heating
Cooling mode
Daytime
Warmer
area
Nighttime
Cooler
area
14
ENERGY-SAVING
Econo Cool Energy-Saving Feature
Ambient temperature
Econo Cool
35C
Set temperature
25C
27C
Perceived temperature
30C
29.3C
SW2
SW3
Energy consumption
OFF
OFF
100%
ON
OFF
75%
ON
ON
50%
OFF
ON
0% (Stop)
ON
16
18
20
22
24
26
28
ATTRACTIVE
Pure White
Auto Vane
Pure white is adopted for the unit colour; white expressing the
essence of cleanliness and easily matching virtually all interior dcor.
AIR QUALITY
Plasma Quad
Plasma Quad attacks bacteria and viruses from inside the unit using
a strong curtain-like electrical field and discharge of electric current
across the whole inlet-air opening of the unit.
Fresh-air Intake
Indoor air quality is enhanced by the direct intake of fresh exterior air.
High-efficiency Filter
This high-performance filter has a much finer mesh compared to standard filters, and is capable of capturing minute particulates floating in
the air that were not previously caught.
Air Purifying
The filter has a large capture area and deodourise the circulating air.
15
Catechin Filter
Catechin is a bioflavonoid by-product of green tea with both antiviral
and antioxidant qualities. It also has an excellent deodourising effect,
which is why Mitsubishi Electric uses the compound in its air conditioner filters. In addition to improving air quality, it prevents the spreading of bacteria and viruses throughout the room. Easily removed for
cleaning and maintenance, when the filter is washed regularly the
deodourising action is rated to last more than 10 years.
Long-life Filter
A special process for the entrapment surface improves the filtering
effect, making the maintenance cycle longer than that of units
equipped with conventional filters.
Silver-ion
Captures the bacteria, pollen and other allergens in the air and neutralises them.
AIR DISTRIBUTION
Double
Vane
Double Vane
Horizontal Vane
The air outlet vane swings up and down so that the airflow is spread
evenly throughout the room.
Vertical Vane
The air outlet fin swings from side to side so that the airflow reaches
every part of the room.
16
FUNCTIONS (2)
CONVENIENCE
On/Off Operation Timer
Use the remote controller to set the times of turning the air conditioner On/Off.
i save Mode
i save is a simplified setting function that recalls the preferred (preset) temperature by pressing
a single button on the remote controller. Press the same button twice in repetition to immediately
return to the previous temperature setting.
Using this function contributes to comfortable waste-free operation, realising the most suitable air
conditioning settings and saving on power consumption when, for example, leaving the room or
going to bed.
Heating
Heating
i save
Auto Changeover
The air conditioner automatically switches between heating and cooling modes to maintain the desired temperature.
Low-temperature Cooling
Intelligent fan speed control in the outdoor unit ensures optimum
performance even when the outside temperature is low.
Auto Restart
Especially useful at the time of power outages, the unit turns back on
automatically when power is restored.
Cool/Dry
SW1
Heat
SW1
ON
ON
5 6
SW2
MXZ-4E83VAHZ
21 A
Default setting
26 A
Operation Lock
To accommodate specific use applications, cooling or heating
operation can be specified when setting the control board of the
outdoor unit. A convenient option when a system needs to be
configured for exclusive cooling or heating service.
17
SW1
Tues.
Wed.
Thurs.
Fri.
Sat.
Sun.
ON 20C
ON 20C
ON 20C
ON 20C
ON 20C
ON 20C
ON 20C
ON 18C
ON 18C
OFF
OFF
OFF
OFF
OFF
Midday is warmer,
so the temperature is set lower
ON 22C
ON 22C
ON 22C
ON 22C
ON 22C
ON 18C
ON 18C
ON 18C
ON 22C
ON 22C
ON 18C
ON 18C
ON 18C
ON 18C
Settings
PUSH
How to set
the Weekly
Timer
PUSH
Ready to set
PUSH
PUSH
Select ON/OFF
Complete
PUSH
PUSH
Start by pushing the SET button and follow the instructions to set the desired patterns.
Once all of the desired patterns are input, point the top end of the remote controller at the
indoor unit and push the SET button one more time. (Push the SET button only after inputting all of the desired patterns into the remote controller memory. Pushing the CANCEL
button will end the set-up process without sending the operation patterns to the indoor unit).
It takes a few seconds to transmit the Weekly Timer operation patterns to the indoor unit.
Please continue to point the remote controller at the indoor unit until all data has been sent.
SYSTEM CONTROL
COMPO (Simultaneous Multi-unit Operation)
PAR-32MAA /PAC-YT52CRA
Units are compatible for use with the PAR-32MAA or PAC-YT52CRA
remote controller, which has a variety of management functions.
M-NET Connection
Units can be connected to MELANS system controllers (M-NET
controllers) such as the AG-150A.
MXZ Connection
Connection to the MXZ multi-split outdoor unit is possible.
Wi-Fi
Interface
Wi-Fi Interface
Interface enabling users to control air conditioners and check operating status via devices such as personal computers, tablets and smartphones.
18
FUNCTIONS (3)
INSTALLATION
Cleaning-free Pipe Reuse
It is possible to reuse the same piping. It allows cleaning-free renewal of air conditioning systems that use R22 or R410 refrigerant.
Control/
Power
3 cores
Outdoor unit
Power supply
Junction
connector
S 1 S2 S 3
L N
Power supply
Control board
Indoor/Outdoor unit
communication
Power
Indoor unit
Control/
Power
3 cores
S 1 S2 S 3
Indoor unit
Power
2 cores
Control
2 cores
Outdoor unit
Power supply
to power
Control board
Indoor/Outdoor unit
communication
Power
Junction connectors
replaced
S1 S2 S3
L N
Power
2 cores
Control
2 cores
L N
S1 S2 S3
Control board
Indoor/Outdoor unit
communication
Power
Junction connectors
replaced
Indoor unit
Control
Outdoor unit
2 cores
(polarised)
S1 S2 S3
L N
Control
2 cores
to power
Power supply
L N
to power
S1 S2 S3
to power
Wiring
confirmation
is time
consuming.
* This function cannot be used when the outdoor temperature is below 0C.
The correction process requires 10 20 minutes, and only works when the unit is set
to the Cooling mode.
Drain Pump
A built-in drain pump enables drain piping to be raised.
Flare Connection
Flare connection to cooling pipe work is possible.
19
MAINTENANCE
Self-Diagnostic Function (Check Code Display)
Check codes are displayed on the remote controller or the operation indicator to inform the user of malfunctions detected.
Wi-Fi
Interface
MELCloud
20
FUNCTION LIST (1 )
Icon
Combination
Category
Technology
Indoor unit
Outdoor unit
MSZ-FH25/35/50VE2
MUZ MXZ MXZ
-FH -2D/E -3E
MXZ
-4E
M SERIES
MSZ-EF18/22/25/35/42/50VE3(W)(B)(S)
MXZ
-5E
MXZ
-4E
MXZ
-5E
MSZ-SF15/20VA
MXZ
-4E
MXZ
-5E
MSZ-SF25/35/42/50VE3
MXZ
-6D
MXZ
-4E
MXZ
-5E
MXZ
-6D
Opt
Opt
DC Inverter
Joint Lap DC Motor
72/83VA
72/83VA
72/83VA
72/83VA
83
83
83
83
72/83VA
72/83VA
72/83VA
72/83VA
72
72
72
72
i-see Sensor
Energy
Saving
Attractive
Pure White
VEW
VEW
VEW
VEW
VEW
VEW
Auto Vane
Air Quality
Plasma Quad
Fresh-air Intake
Silver-ionized Air Purifier Filter
Opt
Opt
Opt
Opt
*1
*1
*1
High-efficiency Filter
Catechin Filter
Air Purifying Filter
Oil Mist Filter
Long-life Filter
Filter Check Signal
Air
Distribution
Double Vane
Horizontal Vane
Vertical Vane
High Ceiling Mode
Silent Mode
Functions
Convenience
*1
*1
*1
*1
*1
*1
*1
*1
*1
*1
*1
*1
*1
*1
*1
*1
*1
Auto Restart
Low-temperature Cooling
Low-noise Operation (Outdoor Unit)
Ampere Limit Adjustment
2E
2E
83
2E
83
83
2E
83
Operation Lock
Built-in Weekly Timer Function
Rotation, Back-up and 2nd Stage Cut-in Functions
System
Control
PAR-32MAA Control *3
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
PAC-YT52CRA Control *3
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
M-NET Connection *3
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
COMPO *4
MXZ Connection
Installation
Maintenance
*1 When multiple indoor units connected to an MXZ outdoor unit are running at the same time, simultaneous cooling and heating is not possible.
*2 For the possible connectivity of MXZ outdoor units and indoor units, please refer to the list on page 97 for details.
*3 Please refer to "System Control" on pages 31-32 for details.
21
M SERIES
MSZ-GF60/71VE2
MUZ
-GF
MXZ
-3E
MXZ
-4E
MXZ
-5E
MSZ-DM25/35VA
MXZ
-6D
MUZ
-DM
MXZ
-2DM
MXZ
-3DM
MSZ-HJ25/35/50VA
MUZ
-HJ
MXZ
-2DM
MXZ
-3DM
MSZHJ60/
71VA
MUZ
-HJ
MFZ-KJ25/35/50VE2
MUFZ
-KJ
MXZ
-2D/E
MXZ
-3E
72/83VA
83
50
72/83VA
72
Opt
*1
Opt
*1
Opt
*1
MXZ
-5E
MXZ
-6D
MXZ
-2D/E
MXZ
-3E
MXZ
-4E
72/83VA
72/83VA
83
83
72/83VA
72/83VA
72
72
MXZ
-5E
MXZ
-6D
35
35
Opt
MXZ
-4E
MLZ-KA25/35/50VA
Opt
*1
*1
*1
*1
2E
83
*1
*1
*1
83
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
*1
*1
*1
*1
*1
2E
83
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
The figures listed in the table are "only when combined with an outdoor unit with the appropriate capacity range".
Opt: Separate parts must be purchased.
22
Technology
P SERIES
S SERIES
Combination
Category
Indoor unit
Outdoor unit
SLZ-KF25/35/50/60VA2 *5
SUZ
-KA
MXZ
-2D/E
MXZ
-3E
MXZ
-4E
MXZ
-5E
SEZ-KD25/35/50/60/71VAL/VAQ
MXZ
-6D
SUZ
-KA
MXZ
-2D/E
MXZ
-3E
MXZ
-4E
MXZ
-5E
PLA-(Z)RP35/50/60/71/100/125/140BA
MXZ
-6D
PUHZ
-SHW
PUHZ
-ZRP
PUHZ
-P
SUZ
-KA
MXZ
-3E
MXZ
-4E
MXZ
-5E
MXZ
-6D
DC Inverter
Joint Lap DC Motor
72/83VA
72/83VA
83
83
35-71
72/83VA
100-140
83
100-250 200/250
72/83VA
72/83VA
72
72
35-71
72/83VA
DC Fan Motor
Vector-Wave Eco Inverter
PAM (Pulse Amplitude Modulation)
35-140 100-140
35-140
72
Grooved Piping
i-see Sensor
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Pure White
Auto Vane
Air Quality
Fresh-air Intake
High-efficiency Filter
Opt
Opt
Opt
Opt
Opt
*1
*1
*1
*1
Horizontal Vane
Vertical Vane
High Ceiling Mode
Low Ceiling Mode
Auto Fan Speed Mode
Convenience
*1
*1
*1
*1
*1
*1
*1
*1
*1
*1
Auto Restart
Functions
Low-temperature Cooling
Low-noise Operation (Outdoor Unit)
Ampere Limit Adjustment
2E
83
60-140V
112/140 200/250
83
2E
Operation Lock
Rotation, Back-up and 2nd Stage Cut-in Functions
Opt
Opt
Opt
200/250
PAR-32MAA Control *3
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
PAC-YT52CRA Control *3
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
M-NET Connection *3
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
*2
*2
*2
*2
Opt
COMPO *4
MXZ Connection
Installation
83
Opt
Opt
71-250
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
*1 When multiple indoor units connected to an MXZ outdoor unit are running at the same time, simultaneous cooling and heating is not possible.
*2 For the possible connectivity of MXZ outdoor units and indoor units, please refer to the list on page 97 for details.
*3 Please refer to "System Control" on pages 31-32 for details.
*4 Please refer to page 18 for details.
23
P SERIES
PEARP200/250
/400/500GAQ
PEAD-RP35/50/60/71/100/125/140JA(L)Q
PUHZ
-SHW
PUHZ
-ZRP
PUHZ
-P
SUZ
-KA
MXZ
-3E
35-71
MXZ
-4E
MXZ
-5E
MXZ
-6D
PUHZ
-ZRP
PUHZ
-P
72/83VA
35-71
60-71
100-140
72/83VA
35-140 100-140
35-140
Opt
PUHZ
-ZRP
100-200
35-71
72
Opt
Opt
Opt
Opt
Opt
Opt
PUHZ PUHZ
-ZRP
-P
100-140
60-140
Opt
Opt
Opt
Opt
Opt
Opt
Opt
200
PUHZ
-ZRP
PUHZ
-P
Opt
Opt
Opt
Opt
PUHZ
-P
71
100/125
250
35-71
100-140
100-250 200/250
35-71
35-140
Opt
PUHZ
-ZRP
100-250
35-71
71-140
Opt
Opt
Opt
Opt
Opt
Opt
*1
*1
*1
*1
71-140
Opt
Opt
Opt
Opt
60-140V
112/140 200/250
Opt
MXZ
-6D
72
200/250
MXZ
-5E
PSA-RP71/
100/125/140KA
83
100-140
35-140
Opt
MXZ
-4E
PCA-RP71HAQ
71
35-140 100-140
Opt
MXZ
-3E
50-71
35-71
Opt
SUZ
-KA
200
60-140V
200/250
83
PUHZ
-P
PCA-RP35/50/60/71/100/125/140KAQ
35-71
Opt
60-140V
112/140 200/250
PKA-RP60/71/100KAL
83
100-140
100-250 200/250
Opt
PKARP35/50HAL
60-140V
200/250
71-140V
200/250
83
71-140V
200/250
Opt
200/250
200/250
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
71-250
Opt
Opt
71-250
*2
Opt
Opt
Opt
*6
*6
*6
*6
*6
*2
*6
*2
*6
71-250
Opt
Opt
Opt
Opt
Opt
Opt
Opt
71-250
Opt
Opt
71-250
*2
*6
Opt
*2
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
*2
*2
*2
Opt
Opt
Opt
Opt
Opt
71-250
Opt
Opt
Opt
Opt
If a numerical figure is listed, the feature is only available with the outdoor unit of that capacity.
Opt: Optional parts must be purchased.
24
CONTROL TECHNOLOGIES
User-friendly Deluxe Remote Controller with Excellent
Operability and Visibility
PAR-32MAA
Multi-language Display
MultiIanguage
PAR-32MAA
English
Spanish
Italian
Turkish
French
Greek
Portuguese
Swedish
English
German
French
Russian
Polish
Czech
Hangarian
Dutch
PAR-32MAAG
Temperature Control
Two preset temperatures
Dual
Set Point
Preset temp.
(COOL)
Room
temperature
Preset temp.
(HEAT)
HEAT
COOL
HEAT
COOL
*Please refer to the function list on pages 23-24 for the combination of
the available units.
Energy-efficient Control
25
Auto-return
After adjusting the temperature for initial heating in winter or cooling on a hot summer day, it is easy to forget to return the temperature setting to its original value. The Auto-return function automatically resets the temperature back to the original setting after a specified period of time, thereby preventing overheating/overcooling.
The Auto-return activation time can be set in 10-minute units, in a
range between 30 and 120 minutes.
Start time
Finish time
Capacity savings
8:15
12:00
80%
12:00
13:00
50%
13:00
17:00
90%
17:00
21:00
50%
Night
Setback
Auto-off
Timer
When using Auto-off Timer, even if one forgets to turn off the unit,
operation stops automatically after the preset time elapses, thereby
preventing wasteful operation. Auto-off Timer can be set in 10minute units, in a range between 30 minutes and 4 hours. Eliminates all anxiety about forgetting to turn off the unit.
This function monitors the room temperature and automatically activates the heating mode when the temperature drops below the
preset minimal temperature setting. It has the same function for
cooling, automatically activating the cooling mode when the temperature rises above the preset maximum temperature setting.
Recommended for
Temperature
Range
Restriction
Operation
Lock
*In-house calculations
Recommended for
(Setting example of minimum temp. in 25C)
19(C)
Changing room
Using a temperature that is 1C lower/higher for heating/cooling results in a 10% reduction in power consumption.* Temperature
Range Restriction limits the maximum and minimum temperature
settings, contributing to the prevention of overheating/overcooling.
Cooling/Dry
Meeting room
Office
Hospital
30(C)
School
Public hall
25(C)
30(C)
Recommended for
Restaurant
Weekly
Timer
Office
The Weekly Timer enables the setting of operation start and finish times and adjusting the temperature as standard features. Up to 8 patterns per
day can be set, providing operation that matches the varying conditions of each period, such as the number of customers in the store.
*Weekly Timer cannot be used when On/Off Timer is in use.
Setting Example
Preparation
26
Busy
hours
25
Opening
time
24
Lunch time
23
22
Closing time
6
5
Dinner time
8-patterns setting
10:00
12:00
14:00
16:00
18:00
20:00
Necessary to change temperature settings for cooling/heating times.
*Joint research conducted with Japan Facility Solutions, Inc.
22:00
24:00 (Time)
26
CONTROL TECHNOLOGIES
Installation/Maintenance Support Functions
Smooth
Maintenance
Manual
Vane Angle
Setting
(4-way ceiling
cassette)
Setting the vertical airflow direction for each individual vane can be
performed simply via illustrated display. Seasonal settings such as
switching between cooling and heating are easily changed as well.
Autodescending
Panel
Operation
Activate Stable
Operation
Data is displayed
Indoor Unit
IU air temp. (C)
IU HEX temp. (C)
Outdoor Unit
Sub cool (C)
10
11
Refrigerant
Leakage
Check
*IU filter operating time is the time elapsed since filter was reset.
Inspection Guidelines
The Mr. Slim Power Inverter units come equipped with a useful
Refrigerant Leakage Check function. Using a wired remote controller, it is easy to check if refrigerant has been lost over a long
period of use. This reduces service time and gives an added sense
of safety.
Item
( 6 OU TH4 temp.) ( 7 OU TH6 temp.)
Cooling
Temp. difference
Heating
Cooling
operation
(C)
45
40
Heating
operation
Inspection C
35
30
10
25
20
(C)
45
40
35
15
Normal
25
20
Inspection B
Normal
10
Inspection A
10 20 30 40 50 60 70 80
(C)
Inspection A
10 20 30 40 50 60 70 80
(C)
10
Result
Normal
Initial
Password
Setting
Filter inspection
Inspection A
Inspection B
Inspection C
1: Due to indoor and outdoor temperatures, Filter inspection may be displayed even if the filter is
not blocked.
The above graphs are based on trial data. Results may vary depending on installation/temperature
conditions.
Stable operation may not be possible under the following temperature conditions:
a) In cooling mode when the outdoor induction temperature is over 40C or the indoor induction
temperature is below 23C.
b) In heating mode when the outdoor induction temperature is over 20C or when the indoor
induction temperature is over 25C.
If the above temperature conditions do not apply and stable operation is not achieved after 30
minutes has passed, please inspect the units.
The operating status may change due to frost on the outdoor heat exchanger.
27
15
Inspection B
10
5
10
Inspection C
Filter inspection
30
Filter inspection
Silent Mode
O/U-1
O/U-2
I/U-1
I/U-2
Sub
unit
Operation Pattern
[Back-up function only]
Start operation
Main
unit
I/U-1
Run
Abnormal condition
Sub
unit
I/U-2
Stop
Run
R/C
Main
unit
I/U-1
Run
Sub
unit
I/U-2
Stop
Main
Sub
Sub
Stop
Run
Run
128 days
Main
Stop
Run
128 days
(Ex: When the request code is 313, each unit operates alternately in daily cycle.)
Operation Pattern
[2nd stage cut-in function]
Start operation
Main
unit
I/U-1
Run
Sub
unit
I/U-2
Stop
Run
Stop
PAC-YT52CRA
Flat
back
120mm
(4-23/32 in)
Backlit LCD
Features a liquid-crystal display (LCD) with backlight for
operation in dark conditions.
Flat Back
Max
14.5mm (9/16 in)
When the operation mode is set to the Auto (Dual Set Point) mode, two preset
temperatures (one each for cooling and heating) can be set. Depending on the
room temperature, indoor unit will automatically operate in either the COOL or
HEAT mode and keep the room temperature within the preset range.
Operation pattern during Auto (Dual Set Point) mode
Pressing the
the vane direction.
Preset temp.
(COOL)
Room
temperature
Preset temp.
(HEAT)
HEAT
AUTO
Setting 1
Setting 2
Setting 3
Setting 4
Setting 5
Swing
COOL
HEAT
COOL
*Please refer to the function list on pages 23-24 for the combination of
the available units.
* The settable vane directions vary depending on the indoor unit model to be connected.
* If the unit has no vane function, the vane direction cannot be set. In this case, the vane icon flashes when the
button is pressed.
28
CONTROL TECHNOLOGIES
Wireless Remote Controller
PAR-SL100A-E
188mm
(7-13/32 in)
Weekly Timer
The Weekly Timer enables the setting of operation start and finish times and adjusting the
temperature as standard features. Up to 4 patterns per day can be set, providing operation that
matches the varying conditions of each period, such as the number of customers in the store.
Tues.
ON 20C
ON 20C
Wed.
Thurs.
Fri.
Sat.
Sun.
ON 20C
ON 20C
ON 20C
ON 20C
ON 20C
ON 18C
ON 18C
OFF
OFF
OFF
OFF
OFF
Midday is warmer,
so the temperature is set lower
ON 20C
ON 20C
ON 20C
ON 20C
ON 20C
ON 20C
(during
sleeping
hours)
ON 18C
ON 18C
ON 18C
ON 20C
ON 18C
ON 18C
ON 18C
ON 18C
*Weekly Timer cannot be used when On/Off Timer is in use. *Only for SLZ-KF25/35/50/60VA2
Backlight
The airflow directions of the four vanes can each be adjusted independently. Easily set the optimum airflow according to the room setting.
Horizontal
Fixed
Adjustable
Downward
Room temperature
Preset temp. (HEAT)
HEAT
29
COOL
HEAT
COOL
Direct
Vane setting
Indirect
Direct
horizontal
swing
keep downward
Cooling
Heating
Direct Airflow
Indirect
keep horizontal
downward
horizontal
Indirect Airflow
Basic Functions
Functions
Liquid crystal
Button
OFF / ON
Preset temperature
Mode
Cool
Dry
Heat
Fan
Auto
Fan speed
Auto
3-Speed
Vane angle
5-step
Swing
Auto
3D i-see Sensor
Direct
Indirect
Send sign
Battery replacement sign
Function setting
Test run
Self check
Not available
*This remote controller is only compatible with the following models: SLZ-KF25/35/50/60VA2 and PLFY-P15/20/25/32/40/50-E1.
*Functions available vary according to the model.
30
SYSTEM CONTROL
Versatile system controls can be realised using optional parts, relay circuits, control panels, etc.
Indoor Unit
Outdoor Unit
P Series Outdoor
Indoor unit
MAC-333IF-E
MAC-397IF-E
Indoor unit
PAR-32MAA Control
PAC-YT52CRA Control
Outdoor unit
PAR-32MAA
PAC-YT52CRA
PAR-32MAA
PAC-YT52CRA
Outdoor unit
Details
Standard equipment (for indoor units compatible with wired remote controllers)
Indoor unit
Indoor unit
Indoor unit
Indoor unit
MAC-333IF-E
MAC-397IF-E
PAR-32MAA
PAC-YT52CRA
PAR-32MAA
PAC-YT52CRA
Outdoor unit
Outdoor unit
Outdoor unit
Outdoor unit
Details
One remote controller can control plural air conditioners with the same settings simultaneously.
One remote controller can control up to 16 refrigerant systems. (When connected to a MXZ unit, MAC-333IF-E or MAC-397IF-E is counted as one system.)
Up to two remote controller can be connected.
PAR-SL100A cannot be used when connected through the MAC-333IF-E or MAC-397IF-E, or when group control is used.
Outdoor unit
Outdoor unit
Indoor unit
Outdoor
unit
Outdoor
unit
Indoor unit
Indoor unit
Outdoor unit
City Multi
indoor unit
M-NET Connections
MAC-333IF-E
ME remote controller
(PAR-F27MEA)
31
Indoor unit
MAC-333IF-E
MAC-397IF-E
PAR-32MAA
PAC-YT52CRA
Outdoor unit
Indoor unit
MELANS
system controller
(AG-150A etc)
PAR-32MAA
PAC-YT52CRA
PAR-32MAA
PAC-YT52CRA
MAC-333IF-E
PAC-SC51KUA
Power supply
unit
Details
PAC-SC51KUA
Power supply
kit
MELANS
system controller
(AG-150A etc)
PAC-SC51KUA
Power supply
unit
Indoor unit
PAR-32MAA
PAC-YT52CRA
City Multi
indoor unit
Outdoor
unit
MELANS
system controller
(AG-150A etc)
PAC-SF83MA-E or PAC-SJ19MA-E
(M-NET converter)
MELANS System controller
PAC-SC51KUA (power supply unit)
Indoor unit
PAR-32MAA
PAC-YT52CRA
Outdoor
unit
M-NET adapter
PAC-SF83MA-E
PAC-SJ19MA-E
OTHERS
For M Series Indoor Units (New A-control Models Only)
System Examples
Remote On/Off
Operation
MAC-333IF-E
MAC-397IF-E
Power supply
MAC-333IF-E
MAC-397IF-E
Resistance LED
Indoor unit
Outdoor unit
Control Details
MAC-333IF-E or MAC-397IF-E
(Interface)
Parts for circuit such as relay
box, lead wire, etc. (to be
purchased locally)
MAC-333IF-E or MAC-397IF-E
(Interface)
Parts for circuit to be
purchased locally (DC power
source needed)
External power source (12V DC)
is required when using
MAC-333IF-E.
Outdoor unit
Remote Display of
Operation Status
Switch
Indoor unit
Connection Details
2-remote Controller
Control
PAR-SL97/100A-E
PAR-32MAA
PAC-YT52CRA
PAR-32MAA
PAC-YT52CRA
(Example of 1 : 1 system)
Remote
control
panel
Wired remote
controller
Operation Control by
Pulse Signal
Remote Display of
Operating Status
Adapter for
remote
On/Off
Remote
control
panel
Wired remote
controller
Operation other than On/Off (e.g., adjustment of temperature, fan speed, and airflow)
can be performed even when remote
controller operation is prohibited.
Timer control is possible with an external
timer.
PAR-SL97/100A-E
PAR-SL97/100A-E
(Example of 1 : 1 system x 2)
Remote operation adapter/
Connector cable for remote display +
Relay box
(Example of 1 : 1 system x 2)
Connector
cable for
remote
display
(Example of 1 : 1 system x 2)
Remote
control
panel
Adapter for
remote
On/Off
(Example of 1 : 1 system x 2)
Operation Control by
Level Signal
Details
Remote
display
panel
PAR-SL97/100A-E
PAR-32MAA /PAC-YT52CRA
(Example of 1 : 1 system)
Timer Operation
PAR-32MAA
(Example of 1 : 1 system)
Weekly Timer:
On/Off and up to 8 pattern temperatures can
be set for each calendar day. (Initial setting)
On/Off Timer:
On/Off can be set once each within 72 hr in
intervals of 5-minute units.
Auto-off Timer:
Operation will be switched off after a certain
time elapse. Set time can be changed from
30 min. to 4 hr. at 10 min. intervals.
Standard functions of
PAR-32MAA
32
SERIES
33
SELECTION
Choose the model that best matches room conditions.
STEP 1
SELECT SERIES
A multiple series line-up to choose from, each with various outstanding features. In addition to inverter-equipped models,
constant-speed, floor-standing and cassette models can be selected. Choose the best series to match usage needs.
Wall-mounted Units
MSZ-F SERIES
MSZ-E SERIES
25/35 25/35
Super
energysaving
SEER SCOP
A+++ A+++
25/35
Ultra-quiet
MSZ-S SERIES
25/35 25/35
SEER SCOP
Cooling
Heating
A+++ A++
MSZ-G SERIES
SEER SCOP
Cooling
Heating
A++ A+
MSZ-D SERIES
Cooling
Heating
MSZ-H SERIES
MSZ-HJ60/71
MSZ-HJ25/35/50
50/60/71 50/60/71
SEER SCOP
A++ A+
SEER SCOP
Cooling
Heating
A+ A+
SEER SCOP
Cooling
Heating
Floor-standing
Cassette Units
MFZ SERIES
MLZ SERIES
Cooling
Heating
25
SEER SCOP
Cooling
Heating
Inverter
Cooling
Heating
A+++ A+
Super
energysaving
Super energy-saving
SEER SCOP
A Energy Rank
Ultra-quiet
Ultra-quiet operation
Cooling
Heating
Compatible for connection to MXZ Series system To confirm compatibility with the MXZ Series multi-type system, refer to the MXZ Series page.
STEP 2
Some outdoor units in the line-up have heaters for use in cold regions. Units with an H in the model name are equipped with heaters.
Heater Installed
MUZ-FH25/35VEHZ
MUZ-EF25/35VEH
MUZ-SF25/35/42VEH
MUFZ-KJ25/35VEHZ
MUZ-FH50VEHZ
MUZ-SF50VEH
MUFZ-KJ50VEHZ
34
MSZ-FH25/35/50VE
MSZ-F
SERIES
25/35
25/35
SEER
SCOP
+++
SEER
9.1
Power consumption has been reduced for the cooling and heating
modes thanks to the incorporation of our newest inverter
technologies. The high energy efficiency of the Size 25 units has
obtained a rating of more than 5.0 for both seasonal coefficient of
performance (SCOP) and seasonal energy efficiency rating (SEER).
SEER
8.9
SCOP
5.1
SCOP
5.1
A+++
Cooling
Heating
SEER
7.2
SCOP
4.6
MSZ-FH25VE
MSZ-FH35VE
MSZ-FH50VE
Hyper Heating
The Hyper Heating feature is incorporated, realizing powerful heating even in the harsh cold. Even users in cold regions can comfortably rely on the MSZ-FH Series for all their heating needs.
Operation Guaranteed at
Outside Temperature of -25C
MUZ-FH VEHZ can be operated at outside temperatures as low as -25C, so there are no concerns
about use even in very cold climates.
MUZ-FH VE
2.5
MUZ-FH VEHZ
-25oC
-20oC
-15oC
kW
-10oC
Freeze-prevention Heater
Equipped as Standard (VEHZ)
MUZ-FH25VE
3.2
kW
MUZ-FH25VEHZ
3.2
kW
MUZ-FH35VE
4.0
Frozen drain
kW
MUZ-FH35VEHZ
35
Air, like water, is something we use everyday unconsciously. Yet, clean, fresh air is a vital part of creating a healthy space for humans.
Achieving this healthy air is Plasma Quad, a plasma-based filter system that effectively removes four kinds of air pollutants; namely, bacteria, viruses, allergens and dust, which the air contains countless particles of.
Bacteria
Viruses
Plasma Quad on
Effective deodorizing
using the filters
Dust
Allergens
(Image)
[ Effective Range ]
Macro
Dust
Particulate size
Allergens
Viruses
Nano
Bad Odours
Bacteria
Mold spores
Plasma Quad
Round:
Air
Dust
Viruses
Pollen
Plasma Quad attacks bacteria and viruses from inside the unit using a strong curtain-like
electrical field and discharge of electric current across the whole inlet-air opening of the
unit. Tungsten discharge electrodes are used as they provide both discharge capacity and
strength. In addition, through flattening the standard, round form of the field to a ribbon-like
shape, a strong electrical field is produced.
Virus
Pet odours
Bacteria
Fish odours
Plasma
field
Rubbish odours
Filter
Neutralization/inactivation
Air
36
Indirect Airflow
Direct Airflow
Sensor with
eight elements
Absence Detection
The sensors detect whether there are people in the room. When no-one is in the room,
the unit automatically switches to energy-saving mode.
8 94 areas
Sensor measures while
moving to the left to right
Divided into 94
(Image)
The 3D i-see Sensor detects peoples absence and the power consumption is automatically reduced
approximately 10% after 10 minutes and 20% after 60 minutes.
Natural Flow
24-hour Timer
To create healthy airflow, the most important aspect is that the flow
of air feels natural. Mitsubishi Electrics solution to this is Natural Flow,
only possible thanks to our technology that freely and flexibly controls
airflow.
Natural Flow (in Cooling)
40.0
Double Vane
Mitsubishi Electrics double
vane separates the airflow
in the left and right directions
to deliver airflow not only
across a wide area of the
room, but also simultaneously
to two people in different
locations.
23.0
23.0
37
120
100
80
60
40
20
140
Kirigamine Highland
20
40
60
80
100
120
Time [s]
Wind of Kirigamine
MSZ-F
25 / 35
25 / 35
SEER SCOP
SERIES
A+++ A+++
Indoor Unit
Outdoor Unit
Remote Controller
MUZ-FH25/35VE
MSZ-FH25/35/50VE2
MUZ-FH50VE
Silver-ion
HUMAN
Natural Flow
HORIZONTAL
VERTICAL
Wi-Fi
Interface
Optional
Optional
Type
Indoor Unit
Outdoor Unit
Refrigerant
Source
Power
Supply Outdoor ( V / Phase / Hz )
Design load
Annual electricity consumption (*2)
SEER (*4)
Cooling
Energy efficiency class
Rated
Capacity
Min-Max
Total Input
Rated
Design load
at reference design temperature
Declared
at bivalent temperature
Capacity
at operation limit temperature
Back
up
heating
capacity
Heating
(Average Annual electricity consumption (*2)
Season)(*5) SCOP (*4)
Energy efficiency class
Rated
Capacity
Min-Max
Total Input
Rated
Operating Current (Max)
Input
Rated
Operating Current(Max)
Dimensions
H*W*D
Weight
Indoor
Cooling
Air Volume (SLo-LoUnit
Mid-Hi-SHi(*3)(Dry/Wet)) Heating
Cooling
Sound Level (SPL)
(SLo-Lo-Mid-Hi-SHi(*3)) Heating
Sound Level (PWL) Cooling
Dimensions
H*W*D
Weight
Cooling
Air Volume
Heating
Outdoor
Cooling
Unit
Sound Level (SPL)
Heating
Sound Level (PWL) Cooling
Operating Current (Max)
Breaker Size
Diameter
Liquid/Gas
Ext.
Max.Length
Out-In
Piping
Max.Height
Out-In
Cooling
Guaranteed Operating
Range (Outdoor)
Heating
Optional
Optional
kW
kWh/a
2.5
96
9.1
A+++
kW
kW
kW
kW
kW
kW
kW
kW
kWh/a
2.5
1.4-3.5
0.485
3.0(-10C)
3.0(-10C)
3.0(-10C)
2.5(-15C)
0.0(-10C)
819
5.1
A+++
3.2
1.8-5.5
0.580
9.6
0.029
0.4
305(+17)-925-234
13.5
3.9-4.7-6.3-8.6-11.6
4.0-4.7-6.4-9.2-13.2
20-23-29-36-42
20-24-29-36-44
58
550-800-285
37
31.3
31.3
46
49
60
9.6
9.2
6.35/9.52
20
12
-10 ~ +46
-15 ~ +24
3.5
0.8-4.0
0.820
3.6(-10C)
3.6(-10C)
3.6(-10C)
3.2(-15C)
0.0(-10C)
986
5.1
A+++
4.0
1.0-6.3
0.800
10.0
0.029
0.4
305(+17)-925-234
13.5
3.9-4.7-6.3-8.6-11.6
4.0-4.7-6.4-9.2-13.2
21-24-29-36-42
21-24-29-36-44
58
550-800-285
37
33.6
33.6
49
50
61
9.6
10
6.35/9.52
20
12
-10 ~ +46
-15 ~ +24
MSZ-FH25VE2
MUZ-FH25VE
kW
kW
kW
A
kW
A
mm
kg
m3/min
m3/min
dB(A)
dB(A)
dB(A)
mm
kg
m3/min
3
m /min
dB(A)
dB(A)
dB(A)
A
A
mm
m
m
C
C
MSZ-FH50VE2
MUZ-FH50VE
5.0
244
7.2
A++
5.0
1.9-6.0
1.380
4.5(-10C)
4.5(-10C)
4.5(-10C)
5.2(-15C)
0.0(-10C)
1372
4.6
A++
6.0
1.7-8.7
1.480
14.0
0.031
0.4
305(+17)-925-234
13.5
6.4-7.4-8.6-10.1-12.4
5.7-7.2-9.0-11.2-14.6
27-31-35-39-44
25-29-34-39-46
60
880-840-330
55
48.8
51.3
51
54
64
13.6
16
6.35 / 12.7
30
15
-10 ~ +46
-15 ~ +24
(*1) Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fluid with
a GWP equal to 1975. This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1 kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit
yourself or disassemble the product yourself and always ask a professional.
(*2) Energy consumption based on standard test results.Actual energy consumption will depend on how the appliance is used and where it is located.
(*3) SHi: Super High
(*4) SEER, SCOP and other related description are based on COMMISSION DELEGATED REGULATION (EU) No.626/2011. The temperature conditions for calculating SCOP are based on Average Season.
(*5) Please see page 47 for heating (warmer season) specifications.
38
MSZ-EF18-50VE2B
MSZ-E
SERIES
Energy-efficient Operation
25-35
25-42*
SEER
SCOP
+++
A++
All models in the series have achieved high energy-savings rating, and are contributing to reduced energy consumption in homes, offices and a range
of other settings. Offered in a variety of output capacities and installation patterns, the vast applicability promises an ideal match for any user.
Rank A for single connection
Outdoor
MUZ-EF25/35VE(H)
MUZ-EF42/50VE
Indoor
MSZ-EF18VE3
Compatibility
2D33VA
2D42VA2
2D53VA2
3E54VA
MXZ
3E68VA
4E72VA
4E83VA
5E102VA
6D122VA
MSZ-EF22VE3
MSZ-EF25VE3
A + + + / A++(A++*)
MSZ-EF35VE3
A + + + / A++(A+*)
MSZ-EF42VE3
A + + / A++
A + + / A+
MSZ-EF50VE3
*VEH
Mitsubishi Electrics advanced Silent Mode fan speed setting provides super-quiet operation as low as 21dB for EF18/22/25/35
models. This unique feature makes the Kirigamine ZEN series ideal
for use in any situation.
Electrical devices consume standby power even when they are not
in actual use. While we obviously strive to reduce power consumption during actual use, reducing this wasted power that cannot be
seen is also very important.
Noise Level
Subway car
interior
Quiet passenger
car interior
(40km/h)
Human
Library interior
hearing limits
Sound of
rustling leaves (Extremely quiet)
without
around 10W
80dB
60dB
40dB
10dB
21dB
(for EF18/22/25/35 models)
Only
An in-company
investigation
Superior Exterior
and Operating Design Concept
The indoor unit of the Kirigamine ZEN keeps its amazingly thin form
even during operation. The only physical change notable is the
movement of the variable vent. As a result, a slim attractive look is
maintained.
Closed
Open
with
Low standby power
1W
around
90%
reduction
(25/35)
MUZ-EF25/35VE
39
below
Heater Installed
MUZ-EF25/35VEH
MSZ-E
25 - 35
25 - 42*
SEER SCOP
SERIES
+++
A++
Indoor Unit
Remote Controller
Outdoor Unit
White
MSZ-EF18/22/25/35/42/50VE3W
MUZ-EF25/35VE(H),42VE
MSZ-EF18/22/25/35/42/50VE3S
Silver
MSZ-EF18/22/25/35/42/50VE3B*
Black
MUZ-EF50VE
Silver-ion
Air Purifying
Wi-Fi
Interface
Optional
Type
Indoor Unit
Outdoor Unit
Refrigerant
Source
Power
Supply Outdoor ( V / Phase / Hz )
Design load
Annual electricity consumption (*2)
SEER (*4)
Cooling
Energy efficiency class
Rated
Capacity
Min-Max
Total Input
Rated
Design load
at reference design temperature
Declared
at bivalent temperature
Capacity
at operation limit temperature
Back
up
heating
capacity
Heating
(Average Annual electricity consumption (*2)
Season)(*5) SCOP (*4)
Energy efficiency class
Rated
Capacity
Min-Max
Total Input
Rated
Operating Current (Max)
Input
Rated
Operating Current(Max)
Dimensions
H*W*D
Weight
Indoor
Cooling
Air Volume (SLo-LoUnit
Mid-Hi-SHi(*3)(Dry/Wet)) Heating
Cooling
Sound Level (SPL)
(SLo-Lo-Mid-Hi-SHi(*3)) Heating
Sound Level (PWL) Cooling
Dimensions
H*W*D
Weight
Cooling
Air Volume
Heating
Outdoor
Cooling
Unit
Sound Level (SPL)
Heating
Sound Level (PWL) Cooling
Operating Current (Max)
Breaker Size
Diameter
Liquid/Gas
Ext.
Max.Length
Out-In
Piping
Max.Height
Out-In
Cooling
Guaranteed Operating
Range (Outdoor)
Heating
MSZ-EF18VE3
MSZ-EF22VE3
for MXZ connection
kW
kWh/a
kW
kW
kW
kW
kW
kW
kW
kW
kWh/a
kW
kW
kW
A
kW
A
mm
kg
m3/min
m3/min
dB(A)
dB(A)
dB(A)
mm
kg
m3/min
3
m /min
dB(A)
dB(A)
dB(A)
A
A
mm
m
m
C
C
0.027
0.3
299-885-195
11.5
4.0 - 4.6 - 6.3 - 8.3 - 10.5
4.0 - 4.6 - 6.2 - 8.9 - 11.9
21 - 23 - 29 - 36 - 42
21 - 24 - 29 - 37 - 45
-
0.027
0.3
299-885-195
11.5
4.0 - 4.6 - 6.3 - 8.3 - 10.5
4.0 - 4.6 - 6.2 - 8.9 - 11.9
21 - 23 - 29 - 36 - 42
21 - 24 - 29 - 37 - 45
-
MSZ-EF25VE3
MUZ-EF25VE
2.5
103
8.5
A+++
2.5
1.2-3.4
0.545
2.4(-10C)
2.4(-10C)
2.4(-10C)
2.0(-15C)
0.0(-10C)
716
4.7
A++
3.2
1.1-4.2
0.700
7.3
0.027
0.3
299-885-195
11.5
4.0 - 4.6 - 6.3 - 8.3 - 10.5
4.0 - 4.6 - 6.2 - 8.9 - 11.9
21 - 23 - 29 - 36 - 42
21 - 24 - 29 - 37 - 45
60
550-800-285
30
32.6
32.2
47
48
58
7.0
10
6.35 / 9.52
20
12
-10 ~ +46
-15 ~ +24
3.5
1.4-4.0
0.910
2.9(-10C)
2.9(-10C)
2.9(-10C)
2.4(-15C)
0.0(-10C)
882
4.6
A++
4.0
1.8-5.5
0.955
8.5
0.031
0.3
299-885-195
11.5
4.0 - 4.6 - 6.3 - 8.3 - 10.5
4.0 - 4.6 - 6.2 - 8.9 - 12.7
21 - 24 - 29 - 36 - 42
21 - 24 - 30 - 38 - 46
60
550-800-285
35
33.6
33.6
49
50
61
8.2
10
6.35 / 9.52
20
12
-10 ~ +46
-15 ~ +24
Optional
Optional
Optional
MSZ-EF35VE3
MUZ-EF35VEH
MSZ-EF42VE3
MUZ-EF42VE
MSZ-EF50VE3
MUZ-EF50VE
3.5
144
8.5
A+++
4.2
192
7.7
A++
5.0
244
7.2
A++
3.5
1.4-4.0
0.910
2.9(-10C)
2.9(-10C)
2.9(-10C)
1.7(-20C)
0.0(-10C)
910
4.5
A+
4.0
1.8-5.5
0.955
8.5
0.031
0.3
299-885-195
11.5
4.0 - 4.6 - 6.3 - 8.3 - 10.5
4.0 - 4.6 - 6.2 - 8.9 - 12.7
21 - 24 - 29 - 36 - 42
21 - 24 - 30 - 38 - 46
60
550-800-285
35
33.6
33.6
49
50
61
8.2
10
6.35 / 9.52
20
12
-10 ~ +46
-20 ~ +24
4.2
0.9-4.6
1.280
3.8(-10C)
3.8(-10C)
3.8(-10C)
3.4(-15C)
0.0(-10C)
1155
4.6
A++
5.4
1.4-6.3
1.460
9.5
0.031
0.3
299-885-195
11.5
5.8 - 6.6 - 7.7 - 8.9 - 10.3
5.5 - 6.3 - 7.8 - 9.9 - 12.7
28 - 31 - 35 - 39 - 42
28 - 30 - 35 - 41 - 48
60
550-800-285
35
35.2
33.6
50
51
62
9.2
10
6.35 / 9.52
20
12
-10 ~ +46
-15 ~ +24
5.0
1.4-5.4
1.560
4.2(-10C)
4.2(-10C)
4.2(-10C)
3.5(-15C)
0.0(-10C)
1309
4.5
A+
5.8
1.6-7.5
1.565
12.4
0.034
0.4
299-885-195
11.5
5.8 - 6.8 - 7.9 - 9.3 - 11.0
6.4 - 7.3 - 9.0 - 11.1 - 13.2
30 - 33 - 36 - 40 - 43
30 - 33 - 37 - 43 - 49
60
880-840-330
54
44.6
44.6
52
52
65
12.0
16
6.35 / 12.7
30
15
-10 ~ +46
-15 ~ +24
(*1) Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fluid with
a GWP equal to 1975. This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1 kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit
yourself or disassemble the product yourself and always ask a professional.
(*2) Energy consumption based on standard test results.Actual energy consumption will depend on how the appliance is used and where it is located.
(*3) SHi: Super High
(*4) SEER, SCOP and other related description are based on COMMISSION DELEGATED REGULATION (EU) No.626/2011. The temperature conditions for calculating SCOP are based on Average Season.
(*5) Please see page 47 for heating (warmer season) specifications.
40
MSZ-S
MSZ-G
MSZ-SF15/20VA
SERIES
MSZ-SF25/35/42/50VE3
SERIES
MSZ-GF60/71VE2
25-71
25-71
SEER
SCOP
++
A+
All models in the series, from the low-capacity 25 to the high-capacity 71, have achieved the Rank A++ for SEER and Rank A+ for SCOP as energy-savings rating. For home use, such as in bedrooms and living rooms, to light commercial use, such as in offices, our air conditioners are contributing to reduced energy consumption in a wide range.
Cooling
Heating
SEER
7.6
SEER
7.5
SEER
7.2
SCOP
4.4
SCOP
4.4
SEER
7.2
SCOP
4.4
SCOP
4.4
SEER
6.8
SCOP
4.3
SEER
6.8
SCOP
4.2
MSZ-SF25VE3
MSZ-SF35VE3
MSZ-SF42VE3
MSZ-SF50VE3
MSZ-GF60VE2
MSZ-GF71VE2
Wide Line-up
Eight different indoor units (Model 15-71) are available to meet your diversified air conditioning needs.
MSZ-SF15 / 20VA*
MSZ-SF25 / 35 / 42 / 50VE3
MSZ-GF60 / 71VE2
(MSZ-SF15/20VA)
The stylish, square indoor unit adds a touch of class to any room interior. The compact design is 64mm thinner than our previous
indoor unit with the lowest output capacity (MSZ-GE22VA).
45mm less
41
38mm less
(MSZ-SF15/20/25/35/42/50)
64mm less
Family Design
Weekly Timer
Easily set desired temperatures and operation start/stop times to match lifestyle patterns. Reduce wasted energy consumption by using the timer
to prevent forgetting to turn off the unit and eliminate temperature setting adjustments.
Example Operation Pattern (Winter/Heating mode)
Mon.
Tues.
Wed.
Thurs.
Fri.
Sat.
Sun.
ON 20C
ON 20C
ON 20C
ON 20C
ON 20C
ON 20C
ON 20C
ON 18C
ON 18C
OFF
OFF
OFF
OFF
OFF
Midday is warmer,
so the temperature is set lower
ON 20C
ON 20C
ON 20C
ON 20C
ON 20C
ON 18C
ON 18C
ON 18C
ON 20C
ON 20C
ON 18C
ON 18C
ON 18C
ON 18C
Settings
PUSH
How to set
the Weekly
Timer
PUSH
Ready to set
PUSH
PUSH
Select ON/OFF
Complete
PUSH
PUSH
Start by pushing the SET button and follow the instructions to set the desired patterns.
Once all of the desired patterns are input, point the top end of the remote controller at the
indoor unit and push the SET button one more time. (Push the SET button only after inputting all of the desired patterns into the remote controller memory. Pushing the CANCEL
button will end the set-up process without sending the operation patterns to the indoor unit).
It takes a few seconds to transmit the Weekly Timer operation patterns to the indoor unit.
Please continue to point the remote controller at the indoor unit until all data has been sent.
When Weekly Timer is set, temperature can not be set 10C.
without
with
below
(MSZ-SF25/35/42/50,MSZ-GF60/71)
around 10W
1W
around
90%
reduction
i save Mode
i save is a simplified setting function that recalls the preferred
(preset) temperature by pressing a single button on the remote controller. Press the same button twice in repetition to immediately
return to the previous temperature setting. Using this function contributes to comfortable, waste-free operation, realising the most
suitable air conditioning settings and saving on power consumption
when, for example, leaving the room or going to bed.
Heating
Heating
18C
22C
(25/35/42/50)
Standard Units
Heater Installed
MUZ-SF25/35/42VE
MUZ-SF50VE
MUZ-SF25/35/42VEH
MUZ-SF50VEH
42
MSZ-S SERIES
Indoor Unit
Remote Controller
Outdoor Unit
Wi-Fi
Interface
Optional
Type
Indoor Unit
Outdoor Unit
Refrigerant
Source
Power
Supply Outdoor ( V / Phase / Hz )
Design load
Annual electricity consumption (*2)
SEER (*4)
Cooling
Energy efficiency class
Rated
Capacity
Min-Max
Total Input
Rated
Design load
at reference design temperature
Declared
at bivalent temperature
Capacity
at operation limit temperature
Heating Back up heating capacity
(Average Annual electricity consumption (*2)
Season)(*5) SCOP (*4)
Energy efficiency class
Rated
Capacity
Min-Max
Total Input
Rated
Operating Current (Max)
Input
Rated
Operating Current(Max)
Dimensions
H*W*D
Weight
Indoor
Cooling
Air Volume (SLo-LoUnit
Mid-Hi-SHi(*3)(Dry/Wet)) Heating
Cooling
Sound Level (SPL)
(SLo-Lo-Mid-Hi-SHi(*3)) Heating
Sound Level (PWL) Cooling
Dimensions
H*W*D
Weight
Cooling
Air Volume
Heating
Outdoor
Cooling
Unit
Sound Level (SPL)
Heating
Sound Level (PWL) Cooling
Operating Current (Max)
Breaker Size
Diameter
Liquid/Gas
Ext.
Max.Length
Out-In
Piping
Max.Height
Out-In
Cooling
Guaranteed Operating
Range (Outdoor)
Heating
MSZ-SF15VA
MSZ-SF20VA
for MXZ connection
kW
kWh/a
kW
kW
kW
kW
kW
kW
kW
kW
kWh/a
kW
kW
kW
A
kW
A
mm
kg
m3/min
m3/min
dB(A)
dB(A)
dB(A)
mm
kg
m3/min
m3/min
dB(A)
dB(A)
dB(A)
A
A
mm
m
m
C
C
0.017
0.019
0.17
0.19
250-760-168
250-760-168
7.7
7.7
3.5 - 3.9 - 4.6 - 5.5 - 6.4 3.5 - 3.9 - 4.6 - 5.5 - 6.9
3.7 - 4.4 - 5.0 - 6.0 - 6.8 3.7 - 4.4 - 5.0 - 6.0 - 7.3
21 - 26 - 30 - 35 - 40
21 - 26 - 30 - 35 - 42
21 - 26 - 30 - 35 - 40
21 - 26 - 30 - 35 - 42
59
60
6.35/9.52
6.35/9.52
-
Optional
Optional
3.2
1.0-4.1
0.780
8.4
0.024
0.2
299-798-195
10
3.2 - 4.1 - 5.6 - 7.2 - 9.1
3.0 - 4.1 - 6.7 - 8.2 - 10.3
19 (*6) - 24 - 30 - 36 - 42
19 (*6) - 24 - 34 - 39 - 45
57
550-800-285
31
31.1
30.7
47
48
58
8.2
10
6.35 / 9.52
20
12
-10 ~ +46
-20 ~ +24
Optional
MSZ-SF35VE3
MUZ-SF35VE
MSZ-SF35VE3
MUZ-SF35VEH
3.5
171
7.2
A++
3.5
1.1-3.8
1.080
2.9(-10C)
2.9(-10C)
2.9(-10C)
2.2(-15C)
0.0(-10C)
923
4.4
A+
3.5
171
7.2
A++
3.5
1.1-3.8
1.080
2.9(-10C)
2.9(-10C)
2.9(-10C)
1.6(-20C)
0.0(-10C)
948
4.3
A+
4.0
1.3-4.6
1.030
8.5
0.027
0.3
299-798-195
10
3.2 - 4.1 - 5.6 - 7.2 - 9.1
3.0 - 4.1 - 6.7 - 8.3 - 11.0
19 (*6) - 24 - 30 - 36 - 42
19 (*6) - 24 - 34 - 40 - 46
57
550-800-285
31
35.9
35.9
49
50
62
8.2
10
6.35 / 9.52
20
12
-10 ~ +46
-15 ~ +24
4.0
1.3-4.6
1.030
8.5
0.027
0.3
299-798-195
10
3.2 - 4.1 - 5.6 - 7.2 - 9.1
3.0 - 4.1 - 6.7 - 8.3 - 11.0
19 (*6) - 24 - 30 - 36 - 42
19 (*6) - 24 - 34 - 40 - 46
57
550-800-285
31
35.9
35.9
49
50
62
8.2
10
6.35 / 9.52
20
12
-10 ~ +46
-20 ~ +24
(*1) Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fluid with
a GWP equal to 1975. This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1 kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit
yourself or disassemble the product yourself and always ask a professional.
(*2) Energy consumption based on standard test results.Actual energy consumption will depend on how the appliance is used and where it is located.
(*3) SHi: Super High
(*4) SEER, SCOP and other related description are based on COMMISSION DELEGATED REGULATION (EU) No.626/2011. The temperature conditions for calculating SCOP are based on Average Season.
(*5) Please see page 47 for heating (warmer season) specifications.
(*6) For single use: only 19dB(A). For multi use (MXZ): 21dB(A).
43
MSZ-S SERIES
MSZ-G SERIES
SEER SCOP
A++ A+
Outdoor Unit
Indoor Unit
MSZ-SF25/35/42/50VE3
MUZ-SF25/35/42VE(H)
MSZ-GF60/71VE2
MUZ-SF50VE(H)
MUZ-GF60/71VE
Silver-ion
Remote Controller
Air Purifying
Optional
Optional
Wi-Fi
Interface
Optional
Optional
Optional
Type
Indoor Unit
Outdoor Unit
Refrigerant
Source
Power
Supply Outdoor ( V / Phase / Hz )
Design load
Annual electricity consumption (*2)
SEER (*4)
Cooling
Energy efficiency class
Rated
Capacity
Min-Max
Total Input
Rated
Design load
at reference design temperature
Declared
at bivalent temperature
Capacity
at operation limit temperature
Heating Back up heating capacity
(Average Annual electricity consumption (*2)
Season)(*5) SCOP (*4)
Energy efficiency class
Rated
Capacity
Min-Max
Total Input
Rated
Operating Current (Max)
Input
Rated
Operating Current(Max)
Dimensions
H*W*D
Weight
Indoor
Cooling
Air Volume (SLo-LoUnit
Mid-Hi-SHi(*3)(Dry/Wet)) Heating
Cooling
Sound Level (SPL)
(SLo-Lo-Mid-Hi-SHi(*3)) Heating
Sound Level (PWL) Cooling
Dimensions
H*W*D
Weight
Cooling
Air Volume
Heating
Outdoor
Cooling
Unit
Sound Level (SPL)
Heating
Sound Level (PWL) Cooling
Operating Current (Max)
Breaker Size
Diameter
Liquid/Gas
Ext.
Out-In
Max.Length
Piping
Max.Height
Out-In
Cooling
Guaranteed Operating
Range (Outdoor)
Heating
kW
kWh/a
kW
kW
kW
kW
kW
kW
kW
kW
kWh/a
kW
kW
kW
A
kW
A
mm
kg
m3/min
m3/min
dB(A)
dB(A)
dB(A)
mm
kg
m3/min
m3/min
dB(A)
dB(A)
dB(A)
A
A
mm
m
m
C
C
MSZ-SF42VE3
MUZ-SF42VE
MSZ-SF42VE3
MUZ-SF42VEH
4.2
196
7.5
A++
4.2
0.8-4.5
1.340
3.8 (-10C)
3.8 (-10C)
3.8 (-10C)
3.4 (-15C)
0.0 (-10C)
1215
4.4
A+
4.2
196
7.5
A++
4.2
0.8-4.5
1.340
3.8 (-10C)
3.8 (-10C)
3.8 (-10C)
2.2 (-20C)
0.0 (-10C)
1242
4.3
A+
5.4
1.3-6.0
1.580
9.5
0.027
0.3
299-798-195
10
4.7 - 5.8 - 6.7 - 7.9 - 9.1
4.7 - 5.8 - 7.2 - 9.1 - 11.4
26(*6) - 31 - 34 - 38 - 42
26(*6) - 31 - 36 - 42 - 47
57
550-800-285
35
35.2
33.6
50
51
63
9.2
10
6.35 / 9.52
20
12
-10 ~ +46
-15 ~ +24
5.4
1.3-6.0
1.58
9.5
0.027
0.3
299-798-195
10
4.7 - 5.8 - 6.7 - 7.9 - 9.1
4.7 - 5.8 - 7.2 - 9.1 - 11.4
26(*6) - 31 - 34 - 38 - 42
26(*6) - 31 - 36 - 42 - 47
57
550-800-285
35
35.2
33.6
50
51
63
9.2
10
6.35 / 9.52
20
12
-10 ~ +46
-20 ~ +24
5.8
1.4-7.3
1.7
12.3
0.035
0.3
299-798-195
10
5.1 - 6.2 - 7.0 - 8.2 - 9.9
5.1 - 6.4 - 8.0 - 9.8 - 12.0
28(*7) - 33 - 36 - 40 - 45
28(*7) - 33 - 38 - 43 - 49
58
880-840-330
55
44.6
44.6
52
52
65
12
16
6.35 / 12.7
30
15
-10 ~ +46
-20 ~ +24
MSZ-GF60VE2
MUZ-GF60VE
MSZ-GF71VE2
MUZ-GF71VE
6.1
311
6.8
A++
6.1
1.4-7.5
1.790
4.6 (-10C)
4.6 (-10C)
4.6 (-10C)
3.7 (-15C)
0.0 (-10C)
1489
4.3
A+
7.1
364
6.8
A++
7.1
2.0-8.7
2.130
6.7 (-10C)
6.7 (-10C)
6.7 (-10C)
5.4 (-15C)
0.0 (-10C)
2204
4.2
A+
6.8
2.0-9.3
1.81
14.5
0.062
0.5
325-1100-238
16
9.8-11.3-13.4-15.6-18.3
9.8-11.3-13.4-15.6-18.3
29 - 37 -41 - 45 - 49
29 - 37 - 41 - 45 - 49
65
880-840-330
50
49.2
49.2
55
55
65
14
20
6.35/15.88
30
15
-10 ~ +46
-15 ~ +24
8.1
2.2-9.9
2.23
16.6
0.058
0.5
325-1100-238
16
9.7-11.5-13.3-15.4-17.8
10.2-11.5-13.3-15.4-17.8
30 - 37 - 41 - 45 - 49
30 - 37 - 41 - 45 - 49
65
880-840-330
53
50.1
48.2
55
55
65
16.1
20
9.52/15.88
30
15
-10 ~ +46
-15 ~ +24
(*1) Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fluid with
a GWP equal to 1975. This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1 kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit
yourself or disassemble the product yourself and always ask a professional.
(*2) Energy consumption based on standard test results.Actual energy consumption will depend on how the appliance is used and where it is located.
(*3) SHi: Super High
(*4) SEER, SCOP and other related description are based on COMMISSION DELEGATED REGULATION (EU) No.626/2011. The temperature conditions for calculating SCOP are based on Average Season.
(*5) Please see page 47 for heating (warmer season) specifications.
(*6) For single use: only 26dB(A), For multi use (MXZ): 28dB(A).
(*7) For single use: only 28dB(A), For multi use (MXZ): 30dB(A).
44
MSZ-DM25 / 35 VA
MSZ-D
SERIES
Compact, high-performance indoor and outdoor units equipped with highperformance air purifying filters contribute to greater room comfort. Wi-Fi and
system controller connectivity enable enhanced expandability.
25/35
25/35
SEER
SCOP
A+
A+
Mitsubishi Electrics cutting-edge inverter technologies are adopted to provide automatic adjustment of operation load according to need. This
reduces excessive consumption of electricity, and thereby realises an Energy Rank A+.
SEER
5.8
Cooling
SEER
5.7
Heating
SCOP
4.1
SCOP
4.1
SCOP Rank A+(4.0)
MSZ-DM25VA
MSZ-DM35VA
MUZ-DM 10C
WiFi interface
Smartphone
Compact Units
The width of both indoor and outdoor units are compact, making
installation in smaller, tighter spaces possible.
Indoor Unit: MSZ-DM25VA
Only 699m
45
m width
MSZ-D SERIES
SEER SCOP
A+
Indoor Unit
A+
Remote
Controller
Outdoor Unit
MUZ-DM25/35VA
MSZ-DM25/35VA
Silver-ion
Wi-Fi
Interface
Optional
Type
Indoor Unit
Outdoor Unit
Refrigerant
Source
Power
Supply Outdoor ( V / Phase / Hz )
Design load
Annual electricity consumption (*2)
SEER (*4)
Cooling
Energy efficiency class
Rated
Capacity
Min-Max
Total Input
Rated
Design load
at reference design temperature
Declared
at bivalent temperature
Capacity
at operation limit temperature
Back
up
heating
capacity
Heating
(Average Annual electricity consumption (*2)
Season)(*5) SCOP (*4)
Energy efficiency class
Rated
Capacity
Min-Max
Total Input
Rated
Operating Current (Max)
Input
Rated
Operating Current(Max)
Dimensions
H*W*D
Weight
Indoor
Cooling
Air Volume (SLo-LoUnit
Mid-Hi-SHi(*3)(Dry/Wet)) Heating
Cooling
Sound Level (SPL)
(SLo-Lo-Mid-Hi-SHi(*3)) Heating
Sound Level (PWL) Cooling
Dimensions
H*W*D
Weight
Cooling
Air Volume
Heating
Outdoor
Cooling
Unit
Sound Level (SPL)
Heating
Sound Level (PWL) Cooling
Operating Current (Max)
Breaker Size
Diameter
Liquid/Gas
Ext.
Max.Length
Out-In
Piping
Max.Height
Out-In
Cooling
Guaranteed Operating
Range (Outdoor)
Heating
Optional
Optional
Optional
MSZ-DM35VA
MUZ-DM35VA
R410A(*1)
Indoor Power supply
230V/Single/50Hz
kW
kWh/a
2.5
149
5.8
A+
3.1
190
5.7
A+
kW
kW
kW
kW
kW
kW
kW
kW
kWh/a
2.5
1.3 - 3.0
0.710
1.9 (-10C)
1.9 (-10C)
1.9 (-10C)
1.9 (-10C)
0.0 (-10C)
647
4.1
A+
3.15
0.9 - 3.5
0.850
5.8
0.020
0.3
290-799-232
9
3.8 - 5.5 - 7.3 - 9.5
3.5 - 5.5 - 7.5 - 10.0
22 - 30 - 37 - 43
23 - 30 - 37 - 43
57
538-699-249
24
31.5
31.5
50
50
63
5.5
10
6.35/9.52
20
12
-10 ~ +46
-10 ~ +24
3.15
1.4 - 3.5
1.020
2.4 (-10C)
2.4 (-10C)
2.4 (-10C)
2.4 (-10C)
0.0 (-10C)
809
4.1
A+
3.6
1.1 - 4.1
0.975
6.5
0.021
0.3
290-799-232
9
3.8 - 5.7 - 7.8 - 10.9
3.5 - 5.5 - 7.5 - 10.3
22 - 31 - 38 - 45
23 - 30 - 37 - 44
60
538-699-249
25
31.5
31.5
51
51
64
6.2
10
6.35/9.52
20
12
-10 ~ +46
-10 ~ +24
kW
kW
kW
A
kW
A
mm
kg
m3/min
m3/min
dB(A)
dB(A)
dB(A)
mm
kg
m3/min
3
m /min
dB(A)
dB(A)
dB(A)
A
A
mm
m
m
C
C
(*1) Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fluid with
a GWP equal to 1975. This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1 kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit
yourself or disassemble the product yourself and always ask a professional.
(*2) Energy consumption based on standard test results.Actual energy consumption will depend on how the appliance is used and where it is located.
(*3) SHi: Super High
(*4) SEER, SCOP and other related description are based on COMMISSION DELEGATED REGULATION (EU) No.626/2011. The temperature conditions for calculating SCOP are based on Average Season.
(*5) Please see page 53 for heating (warmer season) specifications.
46
MSZ-HJ25 / 35 /50VA
MSZ-H
MSZ-HJ60/71VA
SERIES
25/35
25/35
50/60/71
50/60/71
SEER
SCOP
SEER
SCOP
A+
Mitsubishi Electrics cutting-edge inverter technologies are adopted to provide automatic adjustment of operation load according to need. This
reduces excessive consumption of electricity, and thereby realises an Energy Rank A rating for 25/35 classes and A+ for 50/60/71 classes.
Silent Operation
Quiet, relaxing space is within reach. Operational noise is a low 22dB
(25/35 classes). Operation is so silent you might even forget the air
conditioner is on.
Noise Level
Human
Subway car
interior
Quiet passenger
car interior
(40km/h)
Library interior
80dB
60dB
40dB
hearing limits
Sound of
rustling leaves (Extremely quiet)
Only
10dB
22dB
*
An in-company
investigation
*MSZ-HJ25/35VA
Operating Range
MSZ-HJ60/71
MSZ-HJ25/35/50
MSZ-HC
30m
20m
10m
15m
12m
5m
+18C
+43C
+15C
+46C
Compact Units
The widths of both indoor and outdoor units are compact, making
installation in smaller, tighter spaces possible.
Indoor Unit:
MSZ-GF60/71VE
16%
1100mm
Down
New
Only 699m
Indoor Unit:
MSZ-HJ60/71VA
m width
923mm
47
MSZ-H SERIES
50/60/71
50/60/71 50/60/71
SEER SCOP
A+
Indoor Unit
Remote
Controller
Outdoor Unit
MUZ-HJ25/35VA
MSZ-HJ25/35/50VA
A+
MUZ-HJ50VA
MUZ-HJ60/71VA
MSZ-HJ60/71VA
Silver-ion
Optional
Type
Indoor Unit
Outdoor Unit
Refrigerant
Source
Power
Supply Outdoor ( V / Phase / Hz )
Design load
Annual electricity consumption (*2)
SEER (*4)
Cooling
Energy efficiency class
Rated
Capacity
Min-Max
Total Input
Rated
Design load
at reference design temperature
Declared
at bivalent temperature
Capacity
at operation limit temperature
Back
up
heating
capacity
Heating
(Average Annual electricity consumption (*2)
Season)(*5) SCOP (*4)
Energy efficiency class
Rated
Capacity
Min-Max
Total Input
Rated
Operating Current (Max)
Input
Rated
Operating Current(Max)
Dimensions
H*W*D
Weight
Indoor
Cooling
Air Volume (SLo-LoUnit
Mid-Hi-SHi(*3)(Dry/Wet)) Heating
Cooling
Sound Level (SPL)
(SLo-Lo-Mid-Hi-SHi(*3)) Heating
Sound Level (PWL) Cooling
Dimensions
H*W*D
Weight
Cooling
Air Volume
Heating
Outdoor
Cooling
Unit
Sound Level (SPL)
Heating
Sound Level (PWL) Cooling
Operating Current (Max)
Breaker Size
Diameter
Liquid/Gas
Ext.
Max.Length
Out-In
Piping
Max.Height
Out-In
Cooling
Guaranteed Operating
Range (Outdoor)
Heating
kW
kWh/a
kW
kW
kW
kW
kW
kW
kW
kW
kWh/a
kW
kW
kW
A
kW
A
mm
kg
m3/min
m3/min
dB(A)
dB(A)
dB(A)
mm
kg
m3/min
3
m /min
dB(A)
dB(A)
dB(A)
A
A
mm
m
m
C
C
MSZ-HJ25VA
MUZ-HJ25VA
2.5
171
5.1
A
2.5
1.3 - 3.0
0.730
1.9 (-10C)
1.9 (-10C)
1.9 (-10C)
1.9 (-10C)
0.0 (-10C)
698
3.8
A
3.15
0.9 - 3.5
0.870
5.8
0.020
0.3
290-799-232
9
3.8 - 5.5 - 7.3 - 9.5
3.5 - 5.5 - 7.5 - 10.0
22 - 30 - 37 - 43
23 - 30 - 37 - 43
57
538-699-249
24
31.5
31.5
50
50
63
5.5
10
6.35/9.52
20
12
+15 ~ +46
-10 ~ +24
3.1
212
5.1
A
3.15
1.4 - 3.5
1.040
2.4 (-10C)
2.4 (-10C)
2.4 (-10C)
2.4 (-10C)
0.0 (-10C)
885
3.8
A
3.6
1.1 - 4.1
0.995
6.5
0.021
0.3
290-799-232
9
3.8 - 5.7 - 7.8 - 10.9
3.5 - 5.5 - 7.5 - 10.3
22 - 31 - 38 - 45
23 - 30 - 37 - 44
60
538-699-249
25
31.5
31.5
50
50
64
6.2
10
6.35/9.52
20
12
+15 ~ +46
-10 ~ +24
MSZ-HJ50VA
MUZ-HJ50VA
R410A(*1)
Indoor Power supply
230V/Single/50Hz
5.0
292
6.0
A+
MSZ-HJ60VA
MUZ-HJ60VA
MSZ-HJ71VA
MUZ-HJ71VA
6.1
354
6.0
A+
7.1
441
5.6
A+
5.0
1.3 - 5.0
2.050
3.8 (-10C)
3.8 (-10C)
3.8 (-10C)
3.8 (-10C)
0.0 (-10C)
1267
4.2
A+
5.4
1.4 - 6.5
1.480
9.8
0.037
0.4
290-799-232
9
6.3 - 9.1 - 11.1 - 12.9
6.1 - 8.3 - 11.1 - 14.3
28 - 36 - 40 - 45
27 - 34 - 41 - 47
60
550-800-285
36
36.3
34.8
50
51
64
9.4
12
6.35/12.7
20
12
+15 ~ +46
-10 ~ +24
6.1
1.7 - 7.1
1.900
4.6 (-10C)
4.6 (-10C)
4.6 (-10C)
4.6 (-10C)
0.0 (-10C)
1544
4.1
A+
6.8
1.5 - 8.4
1.970
12.5
0.055
0.5
305-923-250
13
9.3 - 12.2 - 15.0 - 19.9
9.4 - 12.5 - 16.0 - 19.9
31 - 38 - 44 - 50
31 - 38 - 44 - 49
65
880-840-330
55
47.9
47.9
55
55
65
12
16
6.35/15.88
30
15
+15 ~ +46
-10 ~ +24
7.1
1.8 - 7.1
2.330
5.4 (-10C)
5.4 (-10C)
5.4 (-10C)
5.4 (-10C)
0.0 (-10C)
1854
4.0
A+
8.1
1.5 - 8.5
2.440
12.5
0.055
0.5
305-923-250
13
10.0 - 12.2 - 15.0 - 19.9
10.3 - 12.7 - 16.4 - 19.9
33 - 38 - 44 - 50
33 - 38 - 44 - 49
65
880-840-330
55
49.3
47.9
55
55
66
12
16
9.52/15.88
30
15
+15 ~ +46
-10 ~ +24
(*1) Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fluid with
a GWP equal to 1975. This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1 kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit
yourself or disassemble the product yourself and always ask a professional.
(*2) Energy consumption based on standard test results.Actual energy consumption will depend on how the appliance is used and where it is located.
(*3) SHi: Super High
(*4) SEER, SCOP and other related description are based on COMMISSION DELEGATED REGULATION (EU) No.626/2011. The temperature conditions for calculating SCOP are based on Average Season.
(*5) Please see page 47 for heating (warmer season) specifications.
48
MFZ-KJ25/35/50VE
MFZ
SERIES
High Capacity, Energy Savings and a Design in Harmony with Living Spaces
Raise the Value of Your Room to the Next Level.
Two-block structure to
accommodate various
installation patterns
Standard
600 mm
750 mm
Semi-inbuilt
145
mm
215
mm
Multi-flow Vane
Three uniquely shaped vanes control the airflow and allow the freedom to customize comfort according to preferences.
When heating
When cooling
Air currents can be
controlled freely
Rapid heating
Warm air is blown
out in a downward
direction and then
sucked back into
the unit to quickly
raise the temperature of the air
being blown out.
* The downward airflow is also possible as well as heating.
25
SEER SCOP
A+++ A+
SEER A+++ (25) and SCOP A+ (25/35/50) ratings have been achieved
through development focusing on compliance with European energy-related product (ErP) regulations.
Cooling
SEER
8.5
SEER
8.1
SCOP
4.5
SCOP
4.4
SEER
6.5
49
MFZ-KJ35VE
Heating
MFZ-KJ25VE
Weekly Timer
MFZ-KJ50VE
Using the original installation plate that comes as standard equipment, installation of the unit is a snap. Levelling adjusters are provided, preventing damage to the wall. Generous pipe length (2030
metres) is provided, so there is no need to worry about distance to
the outdoor unit. All units are equipped with an automatic self-diagnostics function as well. Simply access the trouble log recall mode
for instant troubleshooting.
MFZ-KJ SERIES
25
SEER SCOP
A+++ A+
Indoor Unit
Outdoor Unit
Remote Controller
MUFZ-KJ25/35VE
MFZ-KJ25/35/50VE2
MUFZ-KJ50VE
Silver-ion
Air Purifying
Optional
Optional
Optional
Wi-Fi
Interface
Optional
Type
Indoor Unit
Outdoor Unit
Refrigerant
Source
Power
Supply Outdoor(V/Phase/Hz)
Design load
Annual electricity consumption (*2)
SEER (*4)
Cooling
Energy efficiency class
Capacity
Rated
Min-Max
Total Input
Rated
Design load
at reference design temperature
Declared Capacity
at bivalent temperature
at operation limit temperature
Heating Back up heating capacity
(Average Annual electricity consumption (*2)
Season) SCOP (*4)
Energy efficiency class
Capacity
Rated
Min-Max
Total Input
Rated
Operating Current (Max)
Input
Rated
Operating Current(Max)
Dimensions
H*W*D
Weight
Indoor
Air Volume
Cooling
Unit
(SLo-Lo-Mid-Hi-SHi (*3))
Heating
Sound Level (SPL)
Cooling
(*3)
(SLo-Lo-Mid-Hi-SHi )
Heating
Sound Level (PWL)
Cooling
Dimensions
H*W*D
Weight
Air Volume
Cooling
Heating
Outdoor
Sound Level (SPL)
Cooling
Unit
Heating
Sound Level (PWL)
Cooling
Operating Current(Max)
Breaker Size
Diameter
Liquid/Gas
Ext.
Max.Length
Out-In
Piping
Max.Height
Out-In
Cooling
Guaranteed Operating Range
[Outdoor]
Heating
kW
kWh/a
kW
kW
kW
kW
kW
kW
kW
kW
kWh/a
kW
kW
kW
A
kW
A
mm
kg
m3/min
m3/min
dB(A)
dB(A)
dB(A)
mm
kg
m3/min
m3/min
dB(A)
dB(A)
dB(A)
A
A
mm
m
m
o
C
o
C
MFZ-KJ25VE2
MUFZ-KJ25VE
R410A(*1)
MFZ-KJ35VE2
MUFZ-KJ35VE
R410A(*1)
Outdoor power supply
230 / Single / 50
MFZ-KJ50VE2
MUFZ-KJ50VE
R410A(*1)
2.5
102
8.5
A+++
2.5
0.5 - 3.4
0.540
o
3.4(-10 C)
o
3.4(-10 C)
o
3.4(-10 C)
o
2.4(-15 C)
o
0.0(-10 C)
1059
4.5
A+
3.4
1.2 - 4.6
0.770
9.4
0.016
0.17
600-750-215
15
3.9 - 4.9 - 5.9 - 7.1 - 8.2
3.9 - 5.1 - 6.2 - 7.7 - 9.7
20 - 25 - 30 - 35 - 39
19 - 25 - 30 - 35 - 41
49
550-800-285
37
31.3
33.6
46
51
59
9.2
10
6.35/9.52
20
12
-10 ~ +46
-15 ~ +24
3.5
150
8.1
A++
3.5
0.5 - 3.7
0.940
o
3.5(-10 C)
o
3.5(-10 C)
o
3.5(-10 C)
o
2.9(-15 C)
o
0.0(-10 C)
1110
4.4
A+
4.3
1.2 - 5.5
1.100
9.4
0.016
0.17
600-750-215
15
3.9 - 4.9 - 5.9 - 7.1 - 8.2
3.9 - 5.1 - 6.2 - 7.7 - 9.7
20 - 25 - 30 - 35 - 39
19 - 25 - 30 - 35 - 41
50
550-800-285
37
31.3
33.6
47
51
60
9.2
10
6.35/9.52
20
12
-10 ~ +46
-15 ~ +24
5.0
266
6.5
A++
5.0
1.6 - 5.7
1.410
o
4.4(-10 C)
o
4.4(-10 C)
o
4.4(-10 C)
o
6.0(-15 C)
o
0.0(-10 C)
1406
4.3
A+
6.0
2.2 - 8.2
1.610
14.0
0.038
0.34
600-750-215
15
5.6 - 6.7 - 8.0 - 9.3 - 10.6
6.0 - 7.4 - 9.4 - 11.6 - 14.0
27 - 31 - 35 - 39 - 44
29 - 35 - 40 - 45 - 50
56
880-840-330
55
45.8
45.8
49
51
63
13.6
16
6.35/12.7
30
15
-10 ~ +46
-15 ~ +24
(*1) Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere.
This appliance contains a refrigerant fluid with a GWP equal to 1975. This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher
than 1 kg of CO2 , over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
(*2) Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
(*3) SHi: Super High
(*4) SEER, SCOP and other related description are based on COMMISSION DELEGATED REGULATION (EU) No.626/2011. The temperature conditions for calculating SCOP are based on Average Season.
50
MLZ-KA25/35/50VA
MLZ
SERIES
Introducing a new type of ceiling cassette for the Multi-Split Series with streamed
interior dimensions and a sharp, sleek appearance.
Ceiling Mounted
Slim Body
The new units are designed with a slim body (only 175mm high), ensuring easy installation even when low ceiling cavities limit installation space. The need for ceiling cavity service space is also eliminated, further reducing the dimensions required for installation.
175mm
25
35
50
Standard
2.4m
2.4m
2.4m
High ceiling
2.7m
2.7m
2.7m
Easy Installation
A built-in drain pump (500mm lift) and flexible drain joints make attaching the drain hose in the ceiling cavity easy, resulting in simple and fast
installation. Tight yet flexible fittings eliminate the need of wrapping with heat-insulation tape, and ensure that pipe and drain cover connections
are free of condensation.
Drain
Piping Supporters
Easy joint
connections!
Installation Example
Flexible drain joints
Refrigerant pipe
Insulating material wrapping
only required from this point
Insulation material pretreatment
eliminates need for wrapping.
The newly adopted insulation-free cover eliminates
the need for wrapping pipes with insulation tape and
prevents the forming of condensation.
Drain cover
Easy
Mounting Plate
51
MLZ-KA SERIES
Indoor Unit
Remote Controller
Outdoor Unit
MLZ-KA25/35/50VA
Panel
MLP-443W
Silver-ion
Air Purifying
Wi-Fi
Interface
Optional
Type
Indoor Unit
Outdoor Unit
Refrigerant
Source
Power
Supply Outdoor ( V / Phase / Hz )
Design load
Annual electricity consumption (*2)
SEER (*4)
Cooling
Energy efficiency class
Rated
Capacity
Min-Max
Total Input
Rated
Design load
at reference design temperature
Declared
at bivalent temperature
Capacity
at operation limit temperature
Heating Back up heating capacity
(Average Annual electricity consumption (*2)
Season) SCOP (*4)
Energy efficiency class
Rated
Capacity
Min-Max
Total Input
Rated
Operating Current (Max)
Input
Rated
Operating Current(Max)
Dimensions
H*W*D
Weight
Indoor
Cooling
Air
Volume
(SLo-LoUnit
Mid-Hi-SHi(*3)(Dry/Wet)) Heating
Cooling
Sound Level (SPL)
(SLo-Lo-Mid-Hi-SHi(*3)) Heating
Sound Level (PWL) Cooling
Dimensions
H*W*D
Panel
Weight
Dimensions
H*W*D
Weight
Cooling
Air Volume
Heating
Outdoor
Cooling
Unit
Sound Level (SPL)
Heating
Sound Level (PWL) Cooling
Operating Current (Max)
Breaker Size
Diameter
Liquid/Gas
Ext.
Max.Length
Out-In
Piping
Out-In
Max.Height
Cooling
Guaranteed Operating
Range (Outdoor)
Heating
Optional
MLZ-KA25VA
kW
kWh/a
kW
kW
kW
kW
kW
kW
kW
kW
kWh/a
kW
kW
kW
A
kW
A
mm
kg
m3/min
m3/min
dB(A)
dB(A)
dB(A)
mm
kg
mm
kg
m3/min
3
m /min
dB(A)
dB(A)
dB(A)
A
A
mm
m
m
C
C
0.4
0.040
175-1102-360
15
7.2-8.0-8.8
7.0-8.2-9.2
29-32-35
28-32-36
52
34-1200-414
3.5
6.35/9.52
-
Optional
Optional
Optional
MLZ-KA50VA
0.4
0.040
175-1102-360
15
8.3-9.8-11.4
8.8-10.3-11.8
34-38-43
34-39-43
60
34-1200-414
3.5
6.35/12.7
-
(*1) Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fluid with
a GWP equal to 1975. This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1 kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit
yourself or disassemble the product yourself and always ask a professional.
(*2) Energy consumption based on standard test results.Actual energy consumption will depend on how the appliance is used and where it is located.
(*3) SHi: Super High
(*4) SEER, SCOP and other related description are based on COMMISSION DELEGATED REGULATION (EU) No.626/2011. The temperature conditions for calculating SCOP are based on Average Season.
52
Type
Indoor Unit
Outdoor Unit
Refrigerant
Design load
kW
(*2)
kWh/a
Cooling Annual electricity consumption
SEER
Energy efciency class
kW
Design load
at reference design temperature kW
Declared
at bivalent temperature
kW
Heating Capacity
at operation limit temperature
kW
(Warmer
kW
Season) Back up heating capacity
(*2)
kWh/a
Annual electricity consumption
SCOP
Energy efciency class
Type
Indoor Unit
Outdoor Unit
Refrigerant
Design load
kW
(*2)
kWh/a
Cooling Annual electricity consumption
SEER
Energy efciency class
kW
Design load
at reference design temperature kW
Declared
at bivalent temperature
kW
Heating Capacity
at operation limit temperature
kW
(Warmer
kW
Season) Back up heating capacity
(*2)
kWh/a
Annual electricity consumption
SCOP
Energy efciency class
Type
Indoor Unit
Outdoor Unit
Refrigerant
Design load
kW
(*2)
kWh/a
Cooling Annual electricity consumption
SEER
Energy efciency class
kW
Design load
At reference design temperature kW
Declared
at bivalent temperature
kW
Heating Capacity
at operation limit temperature
kW
(Warmer
kW
Season) Back up heating capacity
(*2)
kWh/a
Annual electricity consumption
SCOP (*4)
Energy efciency class
Type
Indoor Unit
Outdoor Unit
Refrigerant
Design load
kW
(*2)
kWh/a
Cooling Annual electricity consumption
SEER
Energy efciency class
kW
Design load
at reference design temperature kW
Declared
at bivalent temperature
kW
Heating Capacity
at operation limit temperature
kW
(Warmer
kW
Season) Back up heating capacity
kWh/a
Annual electricity consumption (*2)
SCOP
Energy efciency class
MSZ-FH25VE
MUZ-FH25VE
MUZ-FH25VEHZ
2.5
96
9.1
A+++
1.7 (2C)
1.7 (2C)
1.7 (2C)
2.5 (-15C)
0.0 (2C)
376
6.3
A+++
2.5
96
9.1
A+++
1.8 (2C)
1.8 (2C)
1.8 (2C)
1.7 (-25C)
0.0 (2C)
397
6.3
A+++
MSZ-EF25VE2
MUZ-EF25VE
MUZ-EF25VEH
2.5
103
8.5
A+++
1.3 (2C)
1.3 (2C)
1.3 (2C)
2.0 (-15C)
0.0 (2C)
304
6.0
A+++
2.5
103
8.5
A+++
1.3 (2C)
1.3 (2C)
1.3 (2C)
1.6 (-20C)
0.0 (2C)
304
6.0
A+++
MSZ-SF25VE2
MUZ-SF25VE
MUZ-SF25VEH
2.5
116
7.6
A++
1.3 (2C)
1.3 (2C)
1.3 (2C)
2.0 (-15C)
0.0 (2C)
337
5.4
A+++
2.5
116
7.6
A++
1.3 (2C)
1.3 (2C)
1.3 (2C)
1.6 (-20C)
0.0 (2C)
337
5.4
A+++
2.2 (2C)
2.2 (2C)
2.2 (2C)
2.6 (-25C)
0.0 (2C)
471
4.8 / 6.5
A+++
1.6 (2C)
1.6 (2C)
1.6 (2C)
1.7 (-20C)
0.0 (2C)
396
5.7
A+++
MSZ-FH50VE
MUZ-FH50VE
MUZ-FH50VEHZ
5.0
244
7.2
A++
5.0
244
7.2
A++
2.5 (2C)
2.5 (2C)
2.5 (2C)
5.2 (-15C)
0.0 (2C)
614
5.7
A+++
3.3 (2C)
3.3 (2C)
3.3 (2C)
3.8 (-25C)
0.0 (2C)
787
5.9
A+++
MSZ-EF42VE2
MUZ-EF42VE
MSZ-EF50VE2
MUZ-EF50VE
4.2
192
7.7
A++
5.0
244
7.2
A++
2.1 (2C)
2.1 (2C)
2.1 (2C)
3.4 (-15C)
0.0 (2C)
491
6.0
A+++
2.3 (2C)
2.3 (2C)
2.3 (2C)
3.5 (-15C)
0.0 (2C)
557
5.8
A+++
1.6 (2C)
1.6 (2C)
1.6 (2C)
1.6 (-20C)
0.0 (2C)
417
5.4
A+++
2.1 (2C)
2.1 (2C)
2.1 (2C)
3.4 (-15C)
0.0 (2C)
507
5.8
A+++
MSZ-DM25VA
MUZ-DM25VA
MSZ-DM35VA
MUZ-DM35VA
2.5
149
5.8
A+
1.1 (2C)
1.1 (2C)
1.1 (2C)
1.9 (-10C)
0.0 (2C)
325
4.7
A++
3.1
190
5.7
A+
1.3 (2C)
1.3 (2C)
1.3 (2C)
2.4 (-10C)
0.0 (2C)
386
4.7
A++
2.1 (2C)
2.1 (2C)
2.1 (2C)
2.2 (-20C)
0.0 (2C)
507
5.8
A+++
MSZ-SF50VE2
MUZ-SF50VE
MUZ-SF50VEH
5.0
246
7.2
A++
2.3 (2C)
2.3 (2C)
2.3 (2C)
3.4 (-15C)
0.0 (2C)
563
5.7
A+++
5.0
246
7.2
A++
2.3 (2C)
2.3 (2C)
2.3 (2C)
2.3 (-20C)
0.0 (2C)
563
5.7
A+++
3.7 (2C)
3.7 (2C)
3.7 (2C)
5.4 (-15C)
0.0 (2C)
963
5.4
A+++
MSZ-HJ25VA
MUZ-HJ25VA
MSZ-HJ35VA
MUZ-HJ35VA
2.5
171
5.1
A
1.1 (2C)
1.1 (2C)
1.1 (2C)
1.9 (-10C)
0.0 (2C)
356
4.3
A+
3.1
212
5.1
A
1.3 (2C)
1.3 (2C)
1.3 (2C)
2.4 (-10C)
0.0 (2C)
426
4.3
A+
(*1) Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant uid with
a GWP equal to 1975. This means that if 1 kg of this refrigerant uid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1 kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit
yourself or disassemble the product yourself and always ask a professional.
(*2) Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
53
Indoor
Outdoor
Inside
Outside
dB
dB
MFZ-KJ25VE
MUFZ-KJ25VE
MUFZ-KJ25VEHZ
49
49
59
59
Refrigerant
SEER
8.5
8.5
A+++
A+++
Cooling Energy efciency class
(*2)
kWh/a
Annual electricity consumption
102
102
Design load
2.5
2.5
kW
SCOP
4.5/5.1
4.4/5.4
Energy efciency class
A+/A+++
A+/A+++
Heating Annual electricity consumption (*2)
1059/511
1104/490
kWh/a
(Average Design load
kW 3.4 (-10C)/1.9 (2C) 3.5 (-10C)/1.9 (2C)
season/
at reference design temperature kW 3.4 (-10C)/1.9 (2C) 3.5 (-10C)/1.9 (2C)
Warmer
Declared
at bivalent temperature
kW 3.4 (-10C)/1.9 (2C) 3.5 (-10C)/1.9 (2C)
season)
Capacity
at operation limit temperature
kW 2.4 (-15C)/2.4 (-15C) 1.6 (-25C)/1.6 (-25C)
Back up heating capacity
kW 0.0 (-10C)/0.0 (2C) 0.0 (-10C)/0.0 (2C)
Type
Model
MSZ-FH25VE
MUZ-FH25VE
MUZ-FH25VEHZ
58
58
60
60
Indoor
Outdoor
Inside
Outside
dB
dB
Refrigerant
SEER
9.1
9.1
A+++
A+++
Cooling Energy efciency class
kWh/a
Annual electricity consumption (*2)
96
96
Design load
2.5
2.5
kW
SCOP
5.1/6.3
4.9/6.3
Energy efciency class
A+++/A+++
A++/A+++
Heating Annual electricity consumption (*2)
819/376
924/397
kWh/a
(Average Design load
kW 3.0 (-10C)/1.7 (2C) 3.2 (-10C)/1.8 (2C)
season/
at reference design temperature kW 3.0 (-10C)/1.7 (2C) 3.2 (-10C)/1.8 (2C)
Warmer
Declared
at bivalent temperature
kW 3.0 (-10C)/1.7 (2C) 3.2 (-10C)/1.8 (2C)
season)
Capacity
at operation limit temperature
kW 2.5 (-15C)/2.5 (-15C) 1.7 (-25C)/1.7 (-25C)
Back up heating capacity
kW 0.0 (-10C)/0.0 (2C) 0.0 (-10C)/0.0 (2C)
Sound power levels
on cooling mode
Type
Model
Sound power levels
on cooling mode
Indoor
Outdoor
Inside
Outside
dB
dB
MSZ-EF25VE
MUZ-EF25VE
MUZ-EF25VEH
60
60
58
58
Refrigerant
SEER
8.5
8.5
A+++
A+++
Cooling Energy efciency class
(*2)
kWh/a
Annual electricity consumption
103
103
Design load
2.5
2.5
kW
SCOP
4.7/6.0
4.6/6.0
Energy efciency class
A++/A+++
A++/A+++
Heating Annual electricity consumption (*2)
716/304
730/304
kWh/a
(Average Design load
kW 2.4 (-10C)/1.3 (2C) 2.4 (-10C)/1.3 (2C)
season/
at
reference
design
temperature
kW 2.4 (-10C)/1.3 (2C) 2.4 (-10C)/1.3 (2C)
Warmer
Declared
at bivalent temperature
kW 2.4 (-10C)/1.3 (2C) 2.4 (-10C)/1.3 (2C)
season)
Capacity
at operation limit temperature
kW 2.0 (-15C)/2.0 (-15C) 1.6 (-20C)/1.6 (-20C)
Back up heating capacity
kW 0.0 (-10C)/0.0 (2C) 0.0 (-10C)/0.0 (2C)
Type
Model
Sound power levels
on cooling mode
Indoor
Outdoor
Inside
Outside
dB
dB
MSZ-SF25VE2
MUZ-SF25VE
MUZ-SF25VEH
57
57
58
58
Refrigerant
SEER
7.6
7.6
A++
A++
Cooling Energy efciency class
kWh/a
Annual electricity consumption (*2)
116
116
Design load
2.5
2.5
kW
SCOP
4.4/5.4
4.3/5.4
+
+++
+
Energy efciency class
A /A
A /A+++
Heating Annual electricity consumption (*2)
764/337
790/337
kWh/a
(Average Design load
kW 2.4 (-10C)/1.3 (2C) 2.4 (-10C)/1.3 (2C)
season/
at reference design temperature kW 2.4 (-10C)/1.3 (2C) 2.4 (-10C)/1.3 (2C)
Warmer
Declared
at bivalent temperature
kW 2.4 (-10C)/1.3 (2C) 2.4 (-10C)/1.3 (2C)
season)
Capacity
at operation limit temperature
kW 2.0 (-15C)/2.0 (-15C) 1.6 (-20C)/1.6 (-20C)
Back up heating capacity
kW 0.0 (-10C)/0.0 (2C) 0.0 (-10C)/0.0 (2C)
Type
Model
Indoor
Outdoor
Inside
Outside
MSZ-GF60VE
MSZ-GF71VE
MUZ-GF60VE
MUZ-GF71VE
65
65
65
65
R410A GWP 1975 (*1)
6.8
6.8
A++
A++
dB
dB
Refrigerant
SEER
Cooling Energy efciency class
kWh/a
Annual electricity consumption (*2)
364
311
Design load
7.1
6.1
kW
SCOP
4.2/5.4
4.3/5.3
Energy efciency class
A+/A+++
A+/A+++
Heating Annual electricity consumption (*2)
2204/963
1489/664
kWh/a
(Average Design load
kW
4.6 (-10C)/2.5 (2C) 6.7 (-10C)/3.7 (2C)
season/
at
reference
design
temperature
kW
4.6
(-10C)/2.5
(2C)
6.7
(-10C)/3.7 (2C)
Warmer
Declared
at bivalent temperature
kW
4.6 (-10C)/2.5 (2C) 6.7 (-10C)/3.7 (2C)
season)
Capacity
at operation limit temperature
kW 3.7 (-15C)/3.7 (-15C) 5.4 (-15C)/5.4 (-15C)
Back up heating capacity
kW
0.0 (-10C)/0.0 (2C) 0.0 (-10C)/0.0 (2C)
Sound power levels
on cooling mode
1110/499
3.5 (-10C)/1.9 (2C)
3.5 (-10C)/1.9 (2C)
3.5 (-10C)/1.9 (2C)
2.9 (-15C)/2.9 (-15C)
0.0 (-10C)/0.0 (2C)
150
3.5
4.3/5.4
A+/A+++
1158/510
3.6 (-10C)/2.0 (2C)
3.6 (-10C)/2.0 (2C)
3.6 (-10C)/2.0 (2C)
2.3 (-25C)/2.3 (-25C)
0.0 (-10C)/0.0 (2C)
882/396
2.9 (-10C)/1.6 (2C)
2.9 (-10C)/1.6 (2C)
2.9 (-10C)/1.6 (2C)
2.4 (-15C)/2.4 (-15C)
0.0 (-10C)/0.0 (2C)
144
3.5
4.5/5.7
A+/A+++
910/396
2.9 (-10C)/1.6 (2C)
2.9 (-10C)/1.6 (2C)
2.9 (-10C)/1.6 (2C)
1.7 (-20C)/1.7 (-20C)
0.0 (-10C)/0.0 (2C)
MFZ-KJ50VE
MUFZ-KJ50VE
MUFZ-KJ50VEHZ
56
56
63
63
6.5
A++
266
5.0
4.3/5.8
A+/A+++
1406/579
4.4 (-10C)/2.4 (2C)
4.4 (-10C)/2.4 (2C)
4.4 (-10C)/2.4 (2C)
6.0 (-15C)/6.0 (-15C)
0.0 (-10C)/0.0 (2C)
6.5
A++
266
5.0
4.2/5.7
A+/A+++
1467/603
4.5 (-10C)/2.5 (2C)
4.5 (-10C)/2.5 (2C)
4.5 (-10C)/2.5 (2C)
3.3 (-25C)/3.3 (-25C)
0.0 (-10C)/0.0 (2C)
MSZ-FH50VE
MUZ-FH50VE
MUZ-FH50VEHZ
60
60
64
64
7.2
A++
244
5.0
4.6/5.7
++
A /A+++
1372/614
4.5 (-10C)/2.5 (2C)
4.5 (-10C)/2.5 (2C)
4.5 (-10C)/2.5 (2C)
5.2 (-15C)/5.2 (-15C)
0.0 (-10C)/0.0 (2C)
7.2
A++
244
5.0
4.2/5.9
+
A /A+++
2006/787
6.0 (-10C)/3.3 (2C)
6.0 (-10C)/3.3 (2C)
6.0 (-10C)/3.3 (2C)
3.8 (-25C)/3.8 (-25C)
0.0 (-10C)/0.0 (2C)
MSZ-EF42VE
MUZ-EF42VE
60
62
MSZ-EF50VE
MUZ-EF50VE
60
65
7.7
A++
192
4.2
4.6/6.0
A++/A+++
7.2
A++
244
5.0
4.5/5.8
A+/A+++
1155/491
3.8 (-10C)/2.1 (2C)
3.8 (-10C)/2.1 (2C)
3.8 (-10C)/2.1 (2C)
3.4 (-15C)/3.4 (-15C)
0.0 (-10C)/0.0 (2C)
1309/557
4.2 (-10C)/2.3 (2C)
4.2 (-10C)/2.3 (2C)
4.2 (-10C)/2.3 (2C)
3.5 (-15C)/3.5 (-15C)
0.0 (-10C)/0.0 (2C)
MSZ-HJ25VA
MUZ-HJ25VA
57
63
5.1
A
171
2.5
3.8/4.3
A/A+
292
5.0
4.2/5.5
A+/A+++
354
6.1
4.1/5.1
A+/A+++
MSZ-SF50VE2
MUZ-SF50VE
MUZ-SF50VEH
58
58
65
65
7.2
A++
246
5.0
4.4/5.7
+
A /A+++
1351/563
4.2 (-10C)/2.3 (2C)
4.2 (-10C)/2.3 (2C)
4.2 (-10C)/2.3 (2C)
3.4 (-15C)/3.4 (-15C)
0.0 (-10C)/0.0 (2C)
MSZ-HJ71VA
MUZ-HJ71VA
65
66
5.6
A+
441
7.1
4.0/4.9
A+/A++
1267/539
1544/674
1854/813
698/356
885/426
1.9 (-10C)/1.1 (2C) 2.4 (-10C)/1.3 (2C) 3.8 (-10C)/2.1 (2C) 4.6 (-10C)/2.5 (2C) 5.4 (-10C)/2.9 (2C)
1.9 (-10C)/1.1 (2C) 2.4 (-10C)/1.3 (2C) 3.8 (-10C)/2.1 (2C) 4.6 (-10C)/2.5 (2C) 5.4 (-10C)/2.9 (2C)
1.9 (-10C)/1.1 (2C) 2.4 (-10C)/1.3 (2C) 3.8 (-10C)/2.1 (2C) 4.6 (-10C)/2.5 (2C) 5.4 (-10C)/2.9 (2C)
1.9 (-10C)/1.9 (-10C) 2.4 (-10C)/2.4 (-10C) 3.8 (-10C)/3.8 (-10C) 4.6 (-10C)/4.6 (-10C) 5.4 (-10C)/5.4 (-10C)
0.0 (-10C)/0.0 (2C) 0.0 (-10C)/0.0 (2C) 0.0 (-10C)/0.0 (2C) 0.0 (-10C)/0.0 (2C) 0.0 (-10C)/0.0 (2C)
7.2
A++
246
5.0
4.3/5.7
+
A /A+++
1380/563
4.2 (-10C)/2.3(2C)
4.2 (-10C)/2.3 (2C)
4.2 (-10C)/2.3 (2C)
2.3 (-20C)/2.3 (-20C)
0.0 (-10C)/0.0 (2C)
MSZ-DM25VA MSZ-DM35VA
MUZ-DM25VA MUZ-DM35VA
57
60
63
64
R410A GWP 1975 (*1)
5.7
5.8
A+
A+
149
2.5
4.1/4.7
A+/A++
190
3.1
4.1/4.7
A+/A++
809/386
647/325
1.9 (-10C)/1.1 (2C) 2.4 (-10C)/1.3 (2C)
1.9 (-10C)/1.1 (2C) 2.4 (-10C)/1.3 (2C)
1.9 (-10C)/1.1 (2C) 2.4 (-10C)/1.3 (2C)
1.9 (-10C)/1.9 (-10C) 2.4 (-10C)/2.4 (-10C)
0.0 (-10C)/0.0 (2C) 0.0 (-10C)/0.0 (2C)
(*1) Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant uid with
a GWP equal to 1975. This means that if 1 kg of this refrigerant uid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1 kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit
yourself or disassemble the product yourself and always ask a professional.
(*2) Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
54
SERIES
55
SELECTION
Series line-up consists of two types of indoor units.
Choose the model that best matches room conditions.
STEP 1
Select the optimal unit and capacity required to match room construction and air conditioning requirements.
SLZ-KF25VA2
SLZ-KF35VA2
SLZ-KF50VA2
SLZ-KF60VA2
SEZ-KD25VAQ
SEZ-KD35VAQ
SEZ-KD50VAQ
SEZ-KD60VAQ
SEZ-KD71VAQ
Grilles
SEZ-KD25VAL
SEZ-KD35VAL
SEZ-KD50VAL
SEZ-KD60VAL
SEZ-KD71VAL
STEP 2
SUZ-KA25/35VA5
SUZ-KA50/60/71VA5
To confirm compatibility with the MXZ Series multi-type system, refer to the MXZ Series page.
56
SLZ
SLZ-KF25/35/50/60VA2
SERIES
New design
The straight-line form introduced has resulted in a beautiful square design.
Its high affinity ensures the ability to blend in seamlessly with any interior.
The indoor unit is an ideal match for office or store use.
Of course, design matched 22 (600mm*600mm) ceiling construction
specifications.
600mm
600mm
245mm
Lineup
25
35
50
SLZ-KA
SLZ-KF
60
Energy-saving Performance
Previous model
SLZ-KF
[SEER]
New model
Previous model
SLZ-KF
New model
[SCOP]
6.5
6.3
4.3 4.3
6.3
6.2
4.3
4.3
4.2
A++ (6.1)
4.1
4.1
5.8
A+ (4.0)
5.7
5.5
2.5kW
57
3.5kW
5.0kW
6.0kW
2.5kW
3.5kW
5.0kW
6.0kW
Quietness
Cooling
SLZ-KF
SPL [Lo]
Previous model
New model
32dB(A)
30dB(A)
29dB(A)
The sound level has been reduced by 2-4dB thanks to the introduction of a 3D turbo fan, for quieter and more comfortable air conditioning.
29dB(A)
27dB(A)
25dB(A)
2.5kW
25dB(A)
3.5kW
5.0kW
6.0kW
Horizontal Airflow
[Airflow distribution]*
SLZ-KF60VA2.TH
Flow angle,cooling at 20C (ceiling height 2.7m)
2.7
(m/s)
2.0
1.0
The new airflow control completely eliminates that uncomfortable drafty-feeling with the introduction
of a horizontal airflow that spreads across the ceiling. The ideal airflow for offices and restaurants.
Height (m)
0.5
0
4
Easy installation
Temporary hanging hook
The structure of the panel has been revised and is now equipped
with a temporary hanging hook. This has improved work efficiency
during temporary panel installation.
Corner panel
Drain lift
SLZ-KA: up to 500mm
SLZ-KF : up to 850mm
As the result of using a larger drain pan, the maximum drain lifting height has
been increased from 500mm to 850mm, greatly enhancing construction
flexibility compared to the existing model.
58
for S SERIES
Detects number of people
3D i-see Sensor detects the number of people in the room and sets
the air-conditioning power accordingly. This make automatic
power-saving operation possible in places where the number of
people entering and exiting is large. Additionally, when the area is
continuously unoccupied, the system switches to a more enhanced
power-saving mode. Depending on the setting, it will save additional capacity or stop operation altogether.
Detects number
of people
Detects peoples
position
Detects position
and number of people
360
Detection
Detects floor
temperature
8 sensors
2.7m
7.2m
1.1m
12m
53
Floor surface
1C
power
savings
No occupancy energy save mode
2C
power
savings
No occupancy Auto-Off mode
Seasonal airflow*
<When cooling>
Saves energy while keeping a comfortable effective temperature by automatically switching between ventilation and
cooling. When a pre-set temperature
is reached, the air conditioning unit
switches to swing fan operation to
maintain the effective temperature.
This clever function contributes to
keeping a comfortable coolness.
Cooling
59
Auto-Off
<When heating>
The air conditioning unit automatically
switches between circulator and heating.
Wasted heat that accumulates near the
ceiling is reused via circulation. When a
pre-set temperature is reached the air conditioner switches from heating to circulator
and blows air in the horizontal direction. It
pushes down the warm air that has gathered near the ceiling to peoples height,
thereby providing smart heating.
Heating
SLZ-KF SERIES
Heat Caulking
Fixing Method
Indoor Unit
Remote Controller
Outdoor Unit
SUZ-KA25/35VA5
SLZ-KF25/35/50/60VA2
Enclosed in
SLP-2FALM/SLP-2FALME
Grilles
SLP-2FA (only panel)
SLP-2FAL (with signal receiver)
SLP-2FAE (with 3D i-see Sensor)
SLP-2FALE (with signal receiver and 3D i-see Sensor)
SLP-2FALM (with signal receiver and wireless remote controller)
SLP-2FALME (with signal receiver, 3D i-see Sensor and wireless
remote controller)
*optional
*optional
SUZ-KA50/60VA5
VA
Wi-Fi
Interface
Optional
Type
Indoor Unit
SLZ-KF25VA2
SUZ-KA25VA5
Outdoor Unit
Refrigerant
Source
Power
Supply Outdoor (V/Phase/Hz)
Cooling
Capacity
Optional
Optional
Optional
SLZ-KF60VA2
SUZ-KA60VA5
230 / Single / 50
Rated
kW
Min - Max
kW
2.6
1.5 - 3.2
0.684
2.6
144
6.3
A++
3.5
1.4 - 3.9
0.972
3.5
188
6.5
A++
4.6
2.3 - 5.2
1.394
4.6
256
6.3
A++
5.6
2.3 - 6.5
1.767
5.6
316
6.2
A++
3.2
1.3 - 4.2
0.886
2.2
4.0
1.7 - 5.0
1.108
2.6
5.0
1.7 - 6.0
1.558
3.6
6.4
2.5 - 7.4
2.278
4.6
2.0 (10C)
2.0 (7C)
2.0 (10C)
2.3 (10C)
2.3 (7C)
2.3 (10C)
3.2 (10C)
3.2 (7C)
3.2 (10C)
4.0 (10C)
4.0 (7C)
4.0 (10C)
kW
kWh/a
0.2
716
4.3
A+
0.3
845
4.3
A+
0.4
1172
4.3
A+
0.4
1572
4.1
A+
Input
Rated
Operating Current (max)
kW
A
7.2
0.02
8.4
0.02
12.3
0.03
14.4
0.04
Dimensions <Panel> H W D
Weight <Panel>
mm
0.20
245-570-570 <10-625-625>
15 <3>
0.24
245-570-570 <10-625-625>
15 <3>
0.32
245-570-570 <10-625-625>
15 <3>
0.43
245-570-570 <10-625-625>
15 <3>
Cooling
kg
m /min
Heating
m3/min
34.7
34.8
44.6
49.2
Cooling
dB(A)
Heating
dB(A)
47
48
49
50
52
52
55
55
Cooling
Operating Current (max)
dB(A)
58
62
65
65
A
A
7.0
10
8.2
10
12.0
20
14.0
20
mm
6.35 / 9.52
6.35 / 9.52
6.35 / 12.7
6.35 / 15.88
20
12
10 ~ +46
20
12
10 ~ +46
30
30
15 ~ +46
30
30
15 ~ +46
10 ~ +24
10 ~ +24
10 ~ +24
10 ~ +24
Total Input
Rated
kW
Design Load
Annual Electricity Consumption*
kW
kWh/a
SEER
Energy Efficiency Class
Heating Capacity
(Average
Season)
Total Input
Rated
kW
Min - Max
kW
Rated
kW
Design Load
Declared Capacity
kW
at reference design temperature
kW
at bivalent temperature
kW
kW
SCOP
Energy Efficiency Class
Indoor
Unit
m3/min
dB(A)
dB(A)
Outdoor Dimensions
Unit
Weight
Air Volume
Sound Level (SPL)
HWD
kg
Diameter
Liquid / Gas
Max. Length
Out-In
Max. Height
Guaranteed Operating Range
[Outdoor]
Out-In
mm
3
m
C
Cooling
Heating
*1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere.
This appliance contains a refrigerant fluid with a GWP equal to 1975. This means that if 1kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher
than 1kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
*2 Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
60
SEZ
SERIES
SEZ-KD25 -71VAQ/VAL
This concealed ceiling-mounted indoor unit series is compact, and fits easily into
rooms with lowered ceilings. Highly reliable energy-saving performance makes it
a best match choice for concealed unit installations.
A
B
C
D
E
F
G
Width reduced by
Dimension Comparison
110mm
700
1100
990
200
270
SEZ-KA35VA
SEZ-KD25-71VA
70mm
SEZ-KA35-71VA
Height
reduced by
SEZ-KD35VAQ
SEZ-KC25VA
5 Pa
30/50 Pa
5/15/35/50 Pa
SEZ-KA
SEZ-KD
30 Pa
15 Pa
35
30dB
23dB
50
31dB
30dB
60
32dB
30dB
71
32dB
30dB
Maximum noise
reduced by 7dB
61
Air inlet
Air outlet
Access door
Ceiling surface
Canvas duct
Air filter
Inlet grille
SEZ-KD SERIES
Heat Caulking
Fixing Method
Indoor Unit
Remote Controller
Outdoor Unit
SUZ-KA25/35VA5
Enclosed in
SEZ-KD25/35/50/60/71VAL
*optional
(for SEZ-KD VAQ)
SUZ-KA50/60/71VA5
*optional
(for SEZ-KD VAQ)
VAQ
Wi-Fi
Interface
Optional
Type
Indoor Unit
Outdoor Unit
Optional
Optional
Optional
Optional
SEZ-KD35VAQ/VAL
SUZ-KA35VA5
2.5
1.5 - 3.2
0.730
2.5
168
5.2
A
2.9
1.3 - 4.5
0.803
3.5
1.4 - 3.9
1.010
3.5
219
5.6
A+
5.1
2.3 - 5.6
1.580
5.1
313
5.7
A+
4.2
1.7 - 5.0
1.130
2.8
2.5 (10C)
6.4
1.7 - 7.2
1.800
Refrigerant
Source
Power
Supply Outdoor (V/Phase/Hz)
Cooling
Capacity
Total Input
kW
Min - Max
kW
Rated
kW
kW
kWh/a
kW
Min - Max
kW
Rated
kW
Design Load
Declared Capacity
kW
at reference design temperature
kW
at bivalent temperature
kW
kW
2.2
1.9 (10C)
1.9 (7C)
kW
kWh/a
1.9 (10C)
0.3
808
3.8
A
7.4
Input
Rated
Operating Current (max)
kW
A
0.040
0.4
Dimensions <Panel> H W D
Weight <Panel>
mm
SCOP*3
Energy Efficiency Class
Indoor
Unit
m3/min
dB(A)
dB(A)
Air Volume
HWD
Pa
mm
kg
Cooling
m3/min
3
Heating
m /min
Cooling
Heating
dB(A)
Cooling
Operating Current (max)
dB(A)
kg
Outdoor Dimensions
Unit
Weight
Liquid / Gas
Max. Length
Out-In
Max. Height
Guaranteed Operating Range
[Outdoor]
dB(A)
A
A
Diameter
Out-In
SEZ-KD60VAQ/VAL
SUZ-KA60VA5
SEZ-KD71VAQ/VAL
SUZ-KA71VA5
5.6
2.3 - 6.3
1.740
5.6
376
5.2
A
7.4
2.5 - 8.0
2.200
5.5
7.1
2.8 - 8.3
2.210
7.1
477
5.2
A
8.1
2.6 - 10.4
2.268
6.0
4.5 (10C)
5.3 (10C)
5.3 (7C)
5.3 (10C)
230 / Single / 50
Rated
Design Load
Heating Capacity
(Average
Season)
Total Input
SEZ-KD25VAQ/VAL
SUZ-KA25VA5
mm
m
m
C
Cooling
Heating
5 / 15 / 35 / 50
22 - 25 - 29
50
550 - 800 - 285
30
32.6
34.7
47
48
58
7.0
10
6.35 / 9.52
20
12
10 ~ +46
10 ~ +24
2.5 (7C)
2.5 (10C)
0.3
979
4.0
A+
8.7
0.050
0.5
200 - 990 - 700
21
7 - 9 - 11
5 / 15 / 35 / 50
23 - 28 - 33
53
550 - 800 - 285
35
36.3
34.8
49
50
62
8.2
10
6.35 / 9.52
20
12
10 ~ +46
10 ~ +24
4.6
4.1 (10C)
4.1 (7C)
4.1 (10C)
0.5
1653
3.9
A
12.7
4.8 (7C)
4.5 (10C)
1.0
1878
4.1
A+
0.7
2202
3.8
14.7
0.070
A
17.0
0.100
0.7
200 - 1190 - 700
27
0.9
200 - 1190 - 700
27
5 / 15 / 35 / 50
29 - 33 - 36
12 - 15 - 18
5 / 15 / 35 / 50
29 - 33 - 37
12 - 16 - 20
5 / 15 / 35 / 50
29 - 34 - 39
57
880 - 840 - 330
54
58
880 - 840 - 330
50
60
880 - 840 - 330
53
44.6
44.6
52
40.9
49.2
55
50.1
48.2
55
52
65
12.0
55
55
65
14.0
69
16.1
20
6.35 / 12.7
30
20
20
6.35 / 15.88
30
9.52 / 15.88
30
30
15 ~ +46
10 ~ +24
30
30
15 ~ +46
10 ~ +24
15 ~ +46
10 ~ +24
0.070
0.7
200 - 990 - 700
23
10 - 13 - 15
*1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere.
This appliance contains a refrigerant fluid with a GWP equal to 1975. This means that if 1kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher
than 1kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
*2 Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
*3 SEER/SCOP are measured at ESP 35Pa.
62
SERIES
63
SELECTION
Line-up includes a selection of eight indoor units and four series of outdoor units.
Easily construct a system that best matches room air conditioning needs.
STEP 1
Ceiling-suspended
PCA-KAQ
Wall-mounted
PKA-KAL
Ceiling-concealed
PEAD-JA(L)Q
STEP 2
Ceiling-concealed
PEA-GAQ
Professional Kitchen
PCA-HAQ
Floor-standing
PSA-KA
The best outdoor unit for the system depends on the combination of functions desired (e.g. energy savings, system capacity, long pipe length).
Check the specifications of the system you need, and then select the optimum outdoor unit series.
Power Inverter
PUHZ-ZRP100/125/140/200/250
Standard Inverter
PUHZ-ZRP60/71
PUHZ-ZRP35/50
PUHZ-P200/250
PUHZ-P125/140
PUHZ-P100
SUZ-KA50/60/71
SUZ-KA35
To confirm compatibility with the MXZ Series, refer to the MXZ Series page.
SELECT COMBINATION
STEP 3
Choose the installation pattern for the indoor units. (In the case of a multi-system, distribution piping is necessary, so please select the necessary piping as well.)
Single System
Simultaneous Multi-System
Twin
Quadruple
Triple
Twin
50 : 50
Triple
33 : 33 : 33
Quadruple
25 : 25 : 25 : 25
71
35 2
100
50 2
125
60 2
140
71 2
50 3
200
100 2
60 3
50 4
250
125 2
71 3
60 4
Distribution Pipe
MSDD-50TR-E
MSDD-50WR-E
MSDT-111R-E
MSDF-1111R-E
Notes: 1) Indoor unit combinations with floor-standing (PS) units and other types are impossible.
2) The distribution pipe listed is required for simultaneous multi-systems.
64
Power Inverter
SERIES
Series
PLA-ZRP/PUHZ-ZRP
PLA-RP/SUZ-KA
PLA-RP/PUHZ-P
1000
800
600
12%
400
100V
100Y
60
71
Rated Capacity
Results are based on our own simulations. Actual power consumption
may vary depending on how and where the units are used.
50
60V
71V
100V
A++/A+ A++/A++
PLA-RP BA
A++/A+
A+/A+
A+/A
A++/A+
A++/A+
Wall-mounted
PKA-HAL/KAL
A+/A
A/A+
A++/A+
A++/A+
A++/A+
Ceiling-suspended
PCA-KAQ
A++/A+
A+/A+
A++/A+
A++/A+
A+/A
PCA-HAQ
A+/A
Floor-standing
PSA-KA
A++/A+
A+/A+
Ceiling-concealed
PEAD-JAQ
A+/A+
A+/A+
A++/A+
A+/A
A+/A+
200
35
50V
PLA-ZRP BA
saving
35V
21%
23%
saving
saving
saving
saving
saving
14%
2%
15%
The ErP Directive (Lot 10) applies to air conditioners of rated capacity up to 12kW.
The opening for the fan in the outdoor unit is 550mm in diameter. By exchanging
heat more efficiently, this will contribute to energy-saving and low noise level.
A newly designed fan has been adopted, increasing airflow capacity and reducing
operation noise.
2 lines, 64 columns
(ZRP200250)
(ZRP100140)
Indoor
HEX
65
Heat
interchanger
(HIC)
Outdoor
HEX
Power
receiver
LEV A
LEV B
Compressor
LEV C
A HIC circuit has been added to improve energy efficiency during cooling operation. Liquid refrigerant is rerouted, transformed into a gas state and injected back
into the system to increase overall pressure of the refrigerant being sent to the
compressor, thereby reducing the load on the compressor and raising efficiency.
w/ HIC circuit
w/o HIC circuit
All operating capacities have been unified to the side-flow configuration. Even for locations requiring large capacities, the small footprint of these outdoor units enable them to be used anywhere.
Incorporation of a 3-phase power-supply realises a dramatic reduction in operating current. This special technology is equipped in outdoor units to ensure compliance with electromagnetic compatibility
regulations in Europe.
Operating current comparison (for combinations using 4-way ceiling cassettes)
Power Supply
3-phase
8.7
10.3
12.1
Breaker size
16
16
16
Power Supply
PUHZ-ZRP35/50
PUHZ-ZRP60/71
PUHZ-ZRP100/125/140/
200/250
1-phase
27.2
27.3
29.1
32
32
40
PUHZ-ZRP35/50
50m
30m
PUHZ-ZRP60/71
50m
30m
PUHZ-ZRP100/125/140
75m
30m
PUHZ-ZRP200/250
100m
30m
When the total control/power cable length exceeds 80m, separate power sources are
required for the indoor and outdoor units. (An optional power-supply terminal kit is needed
for indoor units with no power-supply terminal block.)
*PUHZ-ZRP200/250 only
R410A refrigerant
Problem
At time of renewal
Chloride residue
At time of
compressor failure
Problem
Result
Accelerated deterioration
of refrigerant oil
Refrigerant circuit malfunctions and causes failure
Technology 1
Original High-quality Filtration
Our original high-quality filtration device called the wide strainer
is equipped inside the refrigerant inlet and outlet pipe. The wide
strainer traps iron particles and realises cleaning-free pipe reuse.
In addition, improvements to the metal used in the bearings of
our new scroll compressors realise more robust units.
Technology 2
Friction Reduction (moving parts in compressor)
Friction inside the compressor is reduced by using an
original Mitsubishi Electric technology called the Heat
Caulking Fixing Method or coating the edge of the blade
in the scroll compressor, thereby suppressing the increase
in temperature that causes refrigerant oil deterioration.
66
PLA-ZRP35/50/60/71/100/125/140BA
PLA-RP35/50/60/71/100/125/140BA
PLA
SERIES
A complete line-up including deluxe units that offer added energy savings. The incorporation of wide air-outlet and the i-see Sensor enhances airflow distribution control, achieving an enhanced level of comfort throughout the room. The synergy of higher energy
efficiency and more comfortable room environment results in the utmost user satisfaction.
Line-up
Series
35
Model
50
60
71
100
125
140
PLA-ZRP35BA
PLA-RP35BA
PLA-ZRP50BA
PLA-RP50BA
PLA-ZRP60BA
PLA-RP60BA
PLA-ZRP71BA
PLA-RP71BA
PLA-ZRP100BA
PLA-RP100BA
PLA-ZRP125BA
PLA-RP125BA
PLA-ZRP140BA
PLA-RP140BA2
Pre-grooved Piping
High-performance pre-grooved piping is utilised,
increasing the heat exchange area.
Power Inverter
Standard Inverter
Power Inverter
Standard Inverter
dummy
PUHZ-P100
PUHZ-P125/140 PUHZ-P200/250
PUHZ-P125/140 PUHZ-P200/250
6.8
SCOP
A++
SEER
A++
6.4
SCOP
A++
4.6
4.6
SEER
A++
6.1
SEER
A++
SCOP
A+
4.2
6.7
SEER
A++
SCOP
A+
6.9
4.5
SCOP
A++
4.8
SEER
A++
6.8
SCOP
A++
4.8
6.4
6.3
4.7
6.1
4.7
6.0
4.5
PLA-ZRP35BA PLA-ZRP50BA PLA-ZRP60BA PLA-ZRP71BA PLA-ZRP100BA PLA-ZRP100BA PLA-ZRP125BA PLA-ZRP125BA PLA-ZRP140BA PLA-ZRP140BA
PUHZ-ZRP35VKA PUHZ-ZRP50VKA PUHZ-ZRP60VHA PUHZ-ZRP71VHA PUHZ-ZRP100VKA2 PUHZ-ZRP100YKA2 PUHZ-ZRP125VKA2 PUHZ-ZRP125YKA2 PUHZ-ZRP140VKA2 PUHZ-ZRP140YKA2
For products with capacity over 10.0kW, SEER/SCOP values are measured based on EN14825. These values are for reference purposes only.
Automatic
descent down
to 4m
1.2m
1.6m
2.0m
2.4m
2.8m
3.2m
3.6m
4.0m
67
4.5
Optimum Airflow
Individual Vane Settings
Optimum airflow settings provide maximum
comfort throughout the room.
Wide Airflow
Wide-angle outlets distribute airflow
to all corners of the room.
Image of multi-directional
air conditioning
Previous
model
Individual Vane
Setting
Horizontal
Airflow direction at each vane
can be set using the wired remote
controller. This function is only
available when indoor unit
connects with PUHZ series.
Adjustable
Wide Airflow
Fixed
Downward
72 airflow patterns
Downward
Downward
Downward Downward
Wave Airflow
Indoor Unit
Indoor Unit
Temperature gap
Uneven temperature distribution
100-140 class
35-71 class
Model
4.5m
2.7m
3.2m
Airflow
pattern
4-Way
3-Way
2-Way
High-ceiling
setting
3.5m
3.5m
3.5m
100-140 class
2.7m
3.0m
3.3m
2.5m
2.7m
3.0m
4.5m
4.5m
4.5m
Standard
setting
Low-ceiling
setting
3.2m
3.6m
4.0m
2.7m
3.0m
3.3m
Horizontal Airflow
An automatic air-speed mode that adjusts airflow speed automatically is adopted to maintain comfortable room conditions at all
times. This setting automatically adjusts the air-speed to conditions
that match the room environment.
[Airflow Distribution]
Strong
Gentle
PLA-RP125BA
Flow angle, cooling at 20C (ceiling height 3.2m)
Height (m)
3.2
3 1.0
2.0
4.0
3.0
Horizontal
Airflow
0
5
(m/s)
5.0
A more
horizontal airflow
is achieved using
the new mode.
Smudge spots on the ceiling may form where the airflow is not evenly distributed.
68
Cooling
Mode
Heating
Mode
temperature-sensing
technology improves energy efficiency
and enhances room comfort
PLP-6BAE
or
90
rotation
5 sec
measurement
90
rotation
5 sec
measurement
90
rotation
5 sec
measurement
5 sec
measurement
PAC-SA1 ME-E
360
sensing
2.7m
11.5m
In Heating Mode
37C
25C
Temperature gap
Temperature felt
28C
26.5C
At start-up
(approx. 30 min)
Floor-level temperature
Temperature felt
Comfortable
without excess
chilliness
28C
26.5C
Air temperature
(intake-air temperature)
At start-up
(approx. 30 min)
32C
32C
Temperature distribution
23C
Temperature distribution
23C
14C
69
13C
Floor-level temperature
37C
25C
13C
Air temperature
(intake-air temperature)
Room air
warmed to
floor level
In Cooling Mode
14C
SERIES SELECTION
100-250
35-71
35-140
35-71
Heat Caulking
Fixing Method
Joint Lap
Indoor Unit
DC Scroll
DC Fan Motor
Grooved Piping
Vector-Wave
Outdoor Unit
For Single
PUHZ-ZRP35/50
PLA-ZRP35/50/60/71/100/125/140BA
PUHZ-ZRP60/71
PUHZ-ZRP100/125/140
Standard Panel
PLP-6BA (only Panel)
PLP-6BALM (with wireless remote controller)
For Multi
(Twin/Triple/Quadruple)
PUHZ-ZRP71
Remote Controller
PUHZ-ZRP100/125/140/200/250
Optional
Optional
Enclosed in PLP-6BALM/PLP-6BALME
35-71
100-250
71-140
100-250
200/250
35-140
25-71
Heat Caulking
Fixing Method
Joint Lap
Indoor Unit
DC Rotary
DC Scroll
DC Fan Motor
Vector-Wave
Grooved Piping
Outdoor Unit
For Single
SUZ-KA35
PLA-RP35/50/60/71/100/125/140BA
SUZ-KA50/60/71
PUHZ-P100
PUHZ-P125/140
PUHZ-P100
PUHZ-P125/140
PUHZ-P200/250
Standard Panel
PLP-6BA (only Panel)
PLP-6BALM (with wireless remote controller)
Remote Controller
Optional
Optional
Enclosed in PLP-6BALM/PLP-6BALME
For Twin
For Single
200
250
50
60
71
100
125
140
Standard Inverter (PUHZ-P & SUZ) 35x1 50x1 60x1 71x1 100x1 125x1 140x1
Distribution Pipe
71
100
125
140
For Triple
200
250
140
200
250
For Quadruple
200
250
35x2 50x2 60x2 71x2 100x2 125x2 50x3 60x3 71x3 50x4 60x4
MSDD-50TR-E
MSDD-50WR-E
MSDT-111R-E
MSDF-1111R-E
50x2 60x2 71x2 100x2 125x2 50x3 60x3 71x3 50x4 60x4
MSDD-50TR-E
MSDD-50WR-E
MSDT-111R-E
MSDF-1111R-E
70
PLZ-RP SERIES
POWER INVERTER
Optional
Optional
Optional
60-140V/200/250
Wi-Fi
Interface
Optional
Type
Indoor Unit
Optional
Optional
Optional
Optional
Outdoor Unit
PLAZRP50BA
PLAZRP60BA
PLAZRP71BA
PUHZZRP50VKA
PUHZZRP60VHA
PUHZZRP71VHA
PLA-ZRP100BA
PLA-ZRP125BA
PLA-ZRP140BA
3.23
3.23
3.07
3.07
6.1
12.5
12.5
13.4
13.4
5.0
7.1
9.5
9.5
3.6
350
685
695
770
781
272
370
484
493
185
6.1
6.4
6.3
6.1*4
6.0*4
6.4
6.7
6.9
6.8
6.8
A++
A++
A++
A++
A++
A++
7.0
14.0
14.0
6.0
8.0
11.2
11.2
4.1
16.0
16.0
2.8 - 8.2
5.0 - 16.0
5.0 - 16.0
2.5 - 7.3
3.5 - 10.2
4.5 - 14.0
4.5 - 14.0
1.6 - 5.2
5.7 - 18.0
5.7 - 18.0
2.04
3.67
3.67
1.57
1.99
2.60
2.60
0.86
4.70
4.70
3.81
3.81
3.40
3.40
4.4
9.3
9.3
3.8
4.7
7.8
7.8
2.4
10.6
10.6
4.4 (10C)
9.3 (10C)
9.3 (10C)
3.8 (10C)
4.7 (10C)
7.8 (10C)
7.8 (10C)
2.4 (10C)
10.6 (10C) 10.6 (10C)
4.4 (10C)
9.3 (10C)
9.3 (10C)
3.8 (10C)
4.7 (10C)
7.8 (10C)
7.8 (10C)
2.4 (10C)
10.6 (10C) 10.6 (10C)
2.8 (20C)
7.0 (20C)
7.0 (20C)
3.7 (11C)
3.5 (20C)
5.8 (20C)
5.8 (20C)
2.2 (11C)
7.9 (20C)
7.9 (20C)
0
0
0
0
0
0
0
0
0
0
1462
2778
2778
1162
1476
2275
2275
729
3324
3324
4.2
4.7*4
4.7*4
4.6
4.5
4.8
4.8
4.6
4.5*4
4.5*4
A+
A++
A+
A++
A++
A++
19.3
13.3
19.5
27.2
8.7
13.3
27.3
10.3
29.1
14.1
0.04
0.04
0.05
0.08
0.08
0.04
0.09
0.09
0.12
0.12
0.30
0.30
0.45
0.74
0.74
0.28
0.80
0.80
1.07
1.07
258 - 840 - 840 <35 - 950 - 950>
298 - 840 - 840 <35 - 950 - 950>
23 <6>
23 <6>
25 <6>
26 <6>
26 <6>
23 <6>
27 <6>
27 <6>
27 <6>
27 <6>
11 - 13 - 15 - 16 12 - 14 - 16 - 18 12 - 14 - 16 - 18 17 - 19 - 21 - 23 20 - 23 - 26 - 30 20 - 23 - 26 - 30 22 - 25 - 28 - 31 22 - 25 - 28 - 31 24 - 26 - 29 - 32 24 - 26 - 29 - 32
27 - 28 - 29 - 31 28 - 29 - 31 - 32 28 - 29 - 31 - 32 28 - 30 - 34 - 36 32 - 34 - 37 - 40 32 - 34 - 37 - 40 34 - 36 - 39 - 41 34 - 36 - 39 - 41 36 - 39 - 42 - 44 36 - 39 - 42 - 44
55
55
58
65
65
54
66
66
70
70
630 - 809 - 300
943 - 950 - 330 (+30)
1338 - 1050 - 330 (+40)
67
46
67
116
123
43
116
125
118
131
55.0
45.0
55.0
110.0
110.0
45.0
120.0
120.0
120.0
120.0
55.0
45.0
55.0
110.0
110.0
45.0
120.0
120.0
120.0
120.0
47
44
47
49
49
44
50
50
50
50
48
46
48
51
51
46
52
52
52
52
67
65
67
69
69
65
70
70
70
70
19.0
13.0
19.0
26.5
8.0
13.0
26.5
9.5
28.0
13.0
25
16
25
32
16
16
32
16
40
16
9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88
6.35 / 12.7
6.35 / 12.7
50
50
50
75
75
50
75
75
75
75
30
30
30
30
30
30
30
30
30
30
15 ~ +46
15 ~ +46
15 ~ +46
15 ~ +46
15 ~ +46
15 ~ +46
15 ~ +46
15 ~ +46
15 ~ +46
15 ~ +46
20 ~ +21
11 ~ +21
20 ~ +21
20 ~ +21
20 ~ +21
11 ~ +21
20 ~ +21
20 ~ +21
20 ~ +21
20 ~ +21
Refrigerant
Power Source
Supply Outdoor (V/Phase/Hz)
kW
Rated
Cooling Capacity
kW
Min - Max
kW
Total Input
Rated
EER
EEL Rank
kW
Design Load
kWh/a
Annual Electricity Consumption*2
SEER
Energy Efficiency Class
kW
Rated
Heating Capacity
(Average
kW
Min - Max
Season) Total Input
kW
Rated
COP
EEL Rank
kW
Design Load
Declared Capacity at reference design temperature kW
kW
at bivalent temperature
kW
at operation limit temperature
kW
Back Up Heating Capacity
kWh/a
Annual Electricity Consumption*2
SCOP
Energy Efficiency Class
A
Operating Current (max)
kW
Indoor Input
Rated
Unit
A
Operating Current (max)
mm
Dimensions <Panel> H W D
kg
Weight <Panel>
m3/min
Air Volume [Lo-Mi2-Mi1-Hi]
dB(A)
Sound Level (SPL) [Lo-Mi2-Mi1-Hi]
dB(A)
Sound Level (PWL)
mm
Outdoor Dimensions
HWD
Unit
kg
Weight
m3/min
Air Volume
Cooling
m3/min
Heating
dB(A)
Sound Level (SPL) Cooling
dB(A)
Heating
dB(A)
Sound Level (PWL) Cooling
A
Operating Current (max)
A
Breaker Size
mm
Ext.
Diameter
Liquid / Gas
Piping Max. Length
m
Out-In
m
Max. Height
Out-In
C
Guaranteed Operating Range Cooling*3
[Outdoor]
C
Heating
*1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance
contains a refrigerant fluid with a GWP equal to 1975. This means that if 1kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1kg of CO2, over a period
of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
*2 Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
*3 Optional air protection guide is required where ambient temperature is lower than 5C. *4 SEER/SCOP values are measured based on EN14825. These values are reference purpose only.
PLZ-P
SPLZ-PSERIES
SERIES
STANDARD INVERTER
PUHZ
Optional
Optional
PUHZ
PUHZ
Optional
PUHZ
SUZ
PUHZ
PUHZ
PUHZ
Wi-Fi
Interface
Optional
Type
Indoor Unit
Outdoor Unit
71
Optional
Optional
Optional
Optional
Optional
PLARP50BA
PLARP60BA
PLARP71BA
SUZKA50VA5
SUZKA60VA5
SUZKA71VA5
PLA-RP100BA
PLA-RP125BA
PLA-RP140BA2
PUHZPUHZPUHZPUHZPUHZPUHZP100VHA4
P100YHA2
P125VHA3
P125YHA
P140VHA3
P140YHA
1
R410A*
Outdoor power supply
VA5 VHA3 VHA4:230 / Single / 50, YHA YHA2:400 / Three / 50
13.6
13.6
12.3
6.1
12.3
5.5
7.1
9.4
9.4
3.6
5.5 - 15.0
5.5 - 15.0
5.5 - 14.0
2.3 - 6.3
5.5 - 14.0
2.3 - 5.6
2.8 - 8.1
4.9 - 11.2
4.9 - 11.2
1.4 - 3.9
5.210
5.210
4.090
1.910
4.090
1.660
2.100
3.120
3.120
1.090
2.61
2.61
3.01
3.01
D
D
B
6.1
5.5
7.1
9.4
9.4
3.6
355
321
429
628
628
210
6.0
6.0
5.8
5.2
5.2
6.0
A+
A+
A+
A
A
A+
16.0
16.0
14.0
7.0
14.0
6.0
8.0
11.2
11.2
4.1
5.0 - 18.0
5.0 - 18.0
5.0 - 16.0
2.5 - 8.0
5.0 - 16.0
1.7 - 7.2
2.6 - 10.2
4.5 - 12.5
4.5 - 12.5
1.7 - 5.0
4.980
4.980
4.110
2.060
4.110
1.750
2.247
3.280
3.280
1.040
3.21
3.21
3.41
3.41
C
C
B
4.6
4.3
5.8
8.0
8.0
2.6
4.0 (10C)
3.8 (10C)
4.7 (10C)
6.3 (10C)
6.3 (10C)
2.3 (10C)
4.1 (7C)
3.8 (7C)
5.1 (7C)
7.1 (7C)
7.1 (7C)
2.3 (7C)
4.0 (10C)
3.8 (10C)
4.7 (10C)
5.0 (15C)
5.0 (15C)
2.3 (10C)
0.6
0.5
1.1
1.7
1.7
0.3
1562
1503
1913
2945
2945
867
4.1
4.0
4.3
3.8
3.8
4.2
A+
A+
A+
A
A
A+
14.0
30.5
14.0
14.4
29.0
12.4
16.6
28.9
13.9
8.4
0.15
0.15
0.15
0.05
0.15
0.05
0.07
0.14
0.14
0.03
1.00
1.00
1.00
0.36
1.00
0.36
0.51
0.94
0.94
0.22
258 - 840 - 840 <35 - 950 - 950>
298 - 840 - 840 <35 - 950 - 950>
27 <6>
27 <6>
25 <6>
23 <6>
25 <6>
22 <6>
23 <6>
25 <6>
25 <6>
22 <6>
11 - 12 - 13 - 15 12 - 14 - 16 - 18 12 - 14 - 16 - 18 14 - 16 - 18- 21 20 - 23 - 26 - 30 20 - 23 - 26 - 30 22 - 25 - 28 - 31 22 - 25 - 28 - 31 24 - 26 - 29 - 32 24 - 26 - 29 - 32
27 - 28 - 29 - 31 28 - 29 - 31 - 32 28 - 29 - 31 - 32 28 - 30 - 32 - 34 32 - 34 - 37 - 40 32 - 34 - 37 - 40 34 - 36 - 39 - 41 34 - 36 - 39 - 41 36 - 39 - 42 - 44 36 - 39 - 42 - 44
70
70
63
55
63
55
56
62
62
54
550 - 800 - 285
880 - 840 - 330
943 - 950 - 330 (+30)
1350 - 950 - 330 (+30)
101
99
101
50
99
54
53
75
77
35
100.0
100.0
100.0
40.9
100.0
44.6
50.1
60.0
60.0
36.3
100.0
100.0
100.0
49.2
100.0
44.6
48.2
60.0
60.0
34.8
52
52
51
55
51
52
55
50
50
49
56
56
55
55
55
52
55
54
54
50
73
73
71
65
71
65
69
70
70
62
13.0
29.5
13.0
14.0
28.0
12.0
16.1
28.0
13.0
8.2
16
40
16
20
32
20
20
32
16
10
6.35 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88
6.35 / 12.7
6.35 / 9.52
50
50
50
30
50
30
30
50
50
20
30
30
30
30
30
30
30
30
30
12
15 ~ +46
15 ~ +46
15 ~ +46
15 ~ +46
15 ~ +46
15 ~ +46
15 ~ +46
15 ~ +46
15 ~ +46
10 ~ +46
15 ~ +21
15 ~ +21
15 ~ +21
10 ~ +24
15 ~ +21
10 ~ +24
10 ~ +24
15 ~ +21
15 ~ +21
10 ~ +24
Refrigerant
Power Source
Supply Outdoor (V/Phase/Hz)
kW
Rated
Cooling Capacity
kW
Min - Max
kW
Total Input
Rated
EER
EEL Rank
kW
Design Load
kWh/a
Annual Electricity Consumption*2
SEER
Energy Efficiency Class
kW
Rated
Heating Capacity
(Average
kW
Min - Max
Season) Total Input
kW
Rated
COP
EEL Rank
kW
Design Load
Declared Capacity at reference design temperature kW
kW
at bivalent temperature
kW
at operation limit temperature
kW
Back Up Heating Capacity
kWh/a
Annual Electricity Consumption*2
SCOP
Energy Efficiency Class
A
Operating Current (max)
kW
Indoor Input
Rated
Unit
A
Operating Current (max)
mm
Dimensions <Panel> H W D
kg
Weight <Panel>
m3/min
Air Volume [Lo-Mi2-Mi1-Hi]
dB(A)
Sound Level (SPL) [Lo-Mi2-Mi1-Hi]
dB(A)
Sound Level (PWL)
mm
Outdoor Dimensions
HWD
Unit
kg
Weight
m3/min
Air Volume
Cooling
m3/min
Heating
dB(A)
Sound Level (SPL) Cooling
dB(A)
Heating
dB(A)
Sound Level (PWL) Cooling
A
Operating Current (max)
A
Breaker Size
mm
Ext.
Diameter
Liquid / Gas
Piping Max. Length
m
Out-In
m
Max. Height
Out-In
C
Guaranteed Operating Range Cooling*3
[Outdoor]
C
Heating
*1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance
contains a refrigerant fluid with a GWP equal to 1975. This means that if 1kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1kg of CO2, over a period
of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
*2 Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
*3 Optional air protection guide is required where ambient temperature is lower than 5C. *4 SEER/SCOP values are measured based on EN14825. These values are reference purpose only.
PLZ-RP SERIES
Optional
Optional
Optional
60-140V/200/250
Wi-Fi
POWER INVERTER
Interface
Optional
Type
Indoor Unit
Optional
Optional
Optional
Optional
Outdoor Unit
PLARP50BA
PLARP60BA
PLARP71BA
PUHZZRP50VKA
PUHZZRP60VHA
PUHZZRP71VHA
PLA-RP100BA
PLA-RP125BA
PLA-RP140BA2
3.13
3.13
3.05
3.05
6.1
12.5
12.5
13.4
13.4
5.0
7.1
9.5
9.5
3.5
371
875
886
849
860
311
387
511
522
189
5.7
5.0*4
4.9*4
5.5*4
5.5*4
5.6
6.4
6.5
6.4
6.5
A+
A+
A++
A++
A++
A++
7.0
6.0
8.0
11.2
11.2
4.1
14.0
14.0
16.0
16.0
2.8 - 8.2
2.5 - 7.3
3.5 - 10.2
4.5 - 14.0
4.5 - 14.0
1.6 - 5.2
5.0 - 16.0
5.0 - 16.0
5.7 - 18.0
5.7 - 18.0
2.17
1.82
2.21
2.95
2.95
0.96
3.91
3.91
4.76
4.76
3.58
3.58
3.36
3.36
4.4
3.8
4.7
7.8
7.8
2.3
9.3
9.3
10.6
10.6
4.4 (10C)
3.8 (10C)
4.7 (10C)
7.8 (10C)
7.8 (10C)
2.3 (10C)
9.3 (10C)
9.3 (10C)
10.6 (10C) 10.6 (10C)
4.4 (10C)
3.8 (10C)
4.7 (10C)
7.8 (10C)
7.8 (10C)
2.3 (10C)
9.3 (10C)
9.3 (10C)
10.6 (10C) 10.6 (10C)
2.8 (20C)
3.7 (11C)
3.5 (20C)
5.8 (20C)
5.8 (20C)
2.2 (11C)
7.0 (20C)
7.0 (20C)
7.9 (20C)
7.9 (20C)
0
0
0
0
0
0
0
0
0
0
1576
1313
1521
2511
2511
750
3304
3304
3746
3746
3.9
4.1
4.3
4.3
4.3
4.3
3.9*4
3.9*4
4.0*4
4.0*4
A
A+
A+
A+
A+
A+
19.4
13.4
19.5
27.4
8.9
13.2
27.5
10.5
29.1
14.1
0.05
0.05
0.07
0.14
0.14
0.03
0.15
0.15
0.16
0.16
0.36
0.36
0.51
0.94
0.94
0.22
1.00
1.00
1.07
1.07
258 - 840 - 840 <35 - 950 - 950>
298 - 840 - 840 <35 - 950 - 950>
23 <6>
22 <6>
23 <6>
25 <6>
25 <6>
22 <6>
25 <6>
25 <6>
27 <6>
27 <6>
11 - 12 - 13 - 15 12 - 14 - 16 - 18 12 - 14 - 16 - 18 14 - 16 - 18 - 21 20 - 23 - 26 - 30 20 - 23 - 26 - 30 22 - 25 - 28 - 31 22 - 25 - 28 - 31 24 - 26 - 29 - 32 24 - 26 - 29 - 32
27 - 28 - 29 - 31 28 - 29 - 31 - 32 28 - 29 - 31 - 32 28 - 30 - 32 - 34 32 - 34 - 37 - 40 32 - 34 - 37 - 40 34 - 36 - 39 - 41 34 - 36 - 39 - 41 36 - 39 - 42 - 44 36 - 39 - 42 - 44
55
55
56
62
62
54
63
63
70
70
630 - 809 - 300
943 - 950 - 330 (+30)
1338 - 1050 - 330 (+40)
67
46
67
116
123
43
116
125
118
131
55.0
45.0
55.0
110.0
110.0
45.0
120.0
120.0
120.0
120.0
55.0
45.0
55.0
110.0
110.0
45.0
120.0
120.0
120.0
120.0
47
44
47
49
49
44
50
50
50
50
48
46
48
51
51
46
52
52
52
52
67
65
67
69
69
65
70
70
70
70
19.0
13.0
19.0
26.5
8.0
13.0
26.5
9.5
28.0
13.0
25
16
25
32
16
16
32
16
40
16
9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88
6.35 / 12.7
6.35 / 12.7
50
50
50
75
75
50
75
75
75
75
30
30
30
30
30
30
30
30
30
30
15 ~ +46
15 ~ +46
15 ~ +46
15 ~ +46
15 ~ +46
15 ~ +46
15 ~ +46
15 ~ +46
15 ~ +46
15 ~ +46
20 ~ +21
11 ~ +21
20 ~ +21
20 ~ +21
20 ~ +21
11 ~ +21
20 ~ +21
20 ~ +21
20 ~ +21
20 ~ +21
Refrigerant
Power Source
Supply Outdoor (V/Phase/Hz)
kW
Rated
Cooling Capacity
kW
Min - Max
kW
Total Input
Rated
EER
EEL Rank
kW
Design Load
kWh/a
Annual Electricity Consumption*2
SEER
Energy Efficiency Class
kW
Rated
Heating Capacity
(Average
kW
Min - Max
Season) Total Input
kW
Rated
COP
EEL Rank
kW
Design Load
Declared Capacity at reference design temperature kW
kW
at bivalent temperature
kW
at operation limit temperature
kW
Back Up Heating Capacity
kWh/a
Annual Electricity Consumption*2
SCOP
Energy Efficiency Class
A
Operating Current (max)
kW
Indoor Input
Rated
Unit
A
Operating Current (max)
mm
Dimensions <Panel> H W D
kg
Weight <Panel>
m3/min
Air Volume [Lo-Mi2-Mi1-Hi]
dB(A)
Sound Level (SPL) [Lo-Mi2-Mi1-Hi]
dB(A)
Sound Level (PWL)
mm
Outdoor Dimensions
HWD
Unit
kg
Weight
m3/min
Air Volume
Cooling
m3/min
Heating
dB(A)
Sound Level (SPL) Cooling
dB(A)
Heating
dB(A)
Sound Level (PWL) Cooling
A
Operating Current (max)
A
Breaker Size
mm
Ext.
Diameter
Liquid / Gas
Piping Max. Length
m
Out-In
m
Max. Height
Out-In
C
Guaranteed Operating Range Cooling*3
[Outdoor]
C
Heating
*1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance
contains a refrigerant fluid with a GWP equal to 1975. This means that if 1kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1kg of CO2, over a period
of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
*2 Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
*3 Optional air protection guide is required where ambient temperature is lower than 5C. *4 SEER/SCOP values are measured based on EN14825. These values are reference purpose only.
PUHZ
PLZ-P
SPLZ-PSERIES
SERIES
Optional
Optional
PUHZ
PUHZ
Optional
PUHZ
SUZ
PUHZ
PUHZ
PUHZ
Wi-Fi
STANDARD INVERTER
Interface
Optional
Optional
Optional
Optional
Optional
Optional
Type
Inverter Heat Pump
Indoor Unit
PLA-ZRP100BA
PLA-ZRP125BA
PLA-ZRP140BA
Outdoor Unit
PUHZ-P100VHA4
PUHZ-P100YHA2
PUHZ-P125VHA3
PUHZ-P125YHA
PUHZ-P140VHA3
PUHZ-P140YHA
1
Refrigerant
R410A*
Outdoor power supply
Power Source
Supply Outdoor (V/Phase/Hz)
230 / Single / 50
400 / Three / 50
230 / Single / 50
400 / Three / 50
230 / Single / 50
400 / Three / 50
13.6
13.6
12.3
12.3
9.4
kW
9.4
Rated
Cooling Capacity
5.5 - 15.0
5.5 - 15.0
5.5 - 14.0
5.5 - 14.0
4.9 - 11.2
kW
4.9 - 11.2
Min - Max
5.171
5.171
4.020
4.020
3.082
kW
3.082
Total Input
Rated
2.63
2.63
3.06
3.06
EER
D
D
B
B
EEL Rank
9.4
kW
9.4
Design Load
610
kWh/a
610
Annual Electricity Consumption*2
5.4
5.4
SEER
A
A
16.0
16.0
14.0
14.0
11.2
kW
11.2
Rated
Heating Capacity
(Average
5.0 - 18.0
5.0 - 18.0
5.0 - 16.0
5.0 - 16.0
4.5 - 12.5
kW
4.5 - 12.5
Min - Max
Season) Total Input
4.938
4.938
3.989
3.989
3.137
kW
3.137
Rated
3.24
3.24
3.51
3.51
COP
C
C
B
B
EEL Rank
8.0
kW
8.0
Design Load
6.3 (10C)
6.3 (10C)
Declared Capacity at reference design temperature kW
7.1 (7C)
kW
7.1 (7C)
at bivalent temperature
5.0 (15C)
kW
5.0 (15C)
at operation limit temperature
1.7
kW
1.7
Back Up Heating Capacity
2800
kWh/a
2800
Annual Electricity Consumption*2
4.0
4.0
SCOP
A+
A+
14.1
30.6
13.8
28.8
A
13.7
Operating Current (max)
28.7
0.12
0.12
0.09
0.09
kW
0.08
Indoor Input
0.08
Rated
Unit
1.07
1.07
0.80
0.80
A
0.74
0.74
Operating Current (max)
mm
Dimensions <Panel> H W D
298 - 840 - 840 <35 - 950 - 950>
27 <6>
27 <6>
27 <6>
27 <6>
kg
26 <6>
26 <6>
Weight <Panel>
24 - 26 - 29 - 32
24 - 26 - 29 - 32
22 - 25 - 28 - 31
22 - 25 - 28 - 31
m3/min
20 - 23 - 26 - 30
20 - 23 - 26 - 30
Air Volume [Lo-Mi2-Mi1-Hi]
36 - 39 - 42 - 44
36 - 39 - 42 - 44
34 - 36 - 39 - 41
34 - 36 - 39 - 41
dB(A)
32 - 34 - 37 - 40
32 - 34 - 37 - 40
Sound Level (SPL) [Lo-Mi2-Mi1-Hi]
70
70
66
66
dB(A)
65
65
Sound Level (PWL)
mm
943 - 950 - 330 (+30)
1350 - 950 - 330 (+30)
Outdoor Dimensions
HWD
Unit
101
99
101
99
kg
77
75
Weight
3
100.0
100.0
100.0
100.0
m /min
60.0
60.0
Air Volume
Cooling
100.0
100.0
100.0
100.0
m3/min
60.0
60.0
Heating
52
52
51
51
dB(A)
50
50
Sound Level (SPL) Cooling
56
56
55
55
dB(A)
54
54
Heating
73
73
71
71
dB(A)
70
70
Sound Level (PWL) Cooling
13.0
29.5
13.0
28.0
A
13.0
28.0
Operating Current (max)
16
40
16
32
A
16
32
Breaker Size
9.52 / 15.88
9.52 / 15.88
9.52 / 15.88
mm
9.52 / 15.88
Ext.
9.52 / 15.88
9.52 / 15.88
Diameter
Liquid / Gas
Piping Max. Length
50
50
50
m
50
50
50
Out-In
30
30
30
m
30
30
30
Max. Height
Out-In
15 ~ +46
15 ~ +46
15 ~ +46
C
15 ~ +46
Guaranteed Operating Range Cooling*3
15 ~ +46
15 ~ +46
[Outdoor]
15 ~ +21
15 ~ +21
15 ~ +21
C
15 ~ +21
15 ~ +21
15 ~ +21
Heating
*1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance
contains a refrigerant fluid with a GWP equal to 1975. This means that if 1kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1kg of CO2, over a period
of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
*2 Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
*3 Optional air protection guide is required where ambient temperature is lower than 5C. *4 SEER/SCOP values are measured based on EN14825. These values are reference purpose only.
72
PEAD
PEAD-RP35/50/60/71/100/125/140JA(L)Q
SERIES
The thin, ceiling-concealed indoor units of this series are the perfect answer for the air
conditioning needs of buildings with minimum ceiling installation space and wideranging external static pressure. Energy-saving efficiency has been improved, reducing electricity consumption and contributing to a further reduction in operating cost.
Reduction of
75mm
250mm
PEAD-RP JA(L)Q
35
50
PEAD-RP EA
60
71
100
30/70Pa
PEAD-RP GA
125
140
10/50/70Pa
35/50/70/100/150Pa
PEAD-RP JA
ErP Lot 10-compliant, Achieving High Energy Efficiency of SEER/SCOP Rank A+ and A++
A direct-current (DC) fan motor is installed in the indoor unit, increasing the seasonal energy efficiency of the newly designed Power Inverter Series
(PUHZ-ZRP) and resulting in compliance of the full-capacity models with ErP Lot 10 and energy rankings of A+/A++ for cooling and A/A+ for heating.
This contributes to an impressive reduction in the cost of annual electricity.
SEER
A+
6.0
SCOP
A+
SEER
A+
5.8
4.0
SCOP
A+
4.3
SEER
A++
6.1
SCOP
A+
4.1
SEER
A+
5.7
SCOP
A
3.9
SEER
A+ SCOP
A+
5.7
4.2
SEER
A+ SCOP
A+
5.6
4.2
5.1
3.9
5.0
3.9
4.9
4.0
4.8
4.0
PEAD-RP35JALQ PEAD-RP50JALQ PEAD-RP60JALQ PEAD-RP71JALQ PEAD-RP100JALQ PEAD-RP100JALQ PEAD-RP125JALQ PEAD-RP125JALQ PEAD-RP140JALQ PEAD-RP140JALQ
PUHZ-ZRP35VKA PUHZ-ZRP50VKA PUHZ-ZRP60VHA PUHZ-ZRP71VHA PUHZ-ZRP100VKA2 PUHZ-ZRP100YKA2 PUHZ-ZRP125VKA2 PUHZ-ZRP125YKA2 PUHZ-ZRP140VKA2 PUHZ-ZRP140YKA2
For products with capacity over 10.0kW, SEER/SCOP values are measured based on EN14825. These values are for reference purposes only.
PEAD-RP JAQ
PEAD-RP JALQ
No drain pump
Units with an L included at the end of the model name are not equipped with a drain pump.
73
SERIES SELECTION
35-140
100-250
35-71
35-71
Heat Caulking
Fixing Method
Joint Lap
Indoor Unit
DC Scroll
Vector-Wave
DC Fan Motor
Grooved Piping
Outdoor Unit
For Single
PUHZ-ZRP35/50
PEAD-RP35/50/60/71/100/125/140
PUHZ-ZRP60/71
PUHZ-ZRP100/125/140
For Multi
(Twin/Triple/Quadruple)
PUHZ-ZRP71
PUHZ-ZRP100/125/140/200/250
Remote Controller
Optional
Optional
Optional
100-250
35-71
100-250
200/250
71-140
35-140
35-71
Heat Caulking
Fixing Method
Joint Lap
Indoor Unit
DC Rotary
DC Fan Motor
DC Scroll
Vector-Wave
Grooved Piping
Outdoor Unit
For Single
SUZ-KA35
PEAD-RP35/50/60/71/100/125/140
SUZ-KA50/60/71
PUHZ-P100
PUHZ-P125/140
PUHZ-P100
PUHZ-P125/140
PUHZ-P200/250
Remote Controller
Optional
Optional
Optional
35
Power Inverter (PUHZ-ZRP )
Distribution Pipe
Standard Inverter (PUHZ-P & SUZ)
Distribution Pipe
For Twin
For Single
200
250
50
60
71
100
125
140
71
100
125
140
For Triple
200
250
140
200
250
For Quadruple
200
250
35x2 50x2 60x2 71x2 100x2 125x2 50x3 60x3 71x3 50x4 60x4
MSDD-50TR-E
MSDD-50WR-E
MSDT-111R-E
MSDF-1111R-E
50x2 60x2 71x2 100x2 125x2 50x3 60x3 71x3 50x4 60x4
MSDD-50TR-E
MSDD-50WR-E
MSDT-111R-E
MSDF-1111R-E
74
PEDZ-RP JA SERIES
60-140V/200/250
PUHZ
Wi-Fi
Interface
POWER INVERTER
Optional
Optional
Optional
Optional
Optional
JAQ
Optional
Type
Indoor Unit
Outdoor Unit
PEADRP50JA(L)Q
PEADRP60JA(L)Q
PEADRP71JA(L)Q
PUHZZRP50VKA
PUHZZRP60VHA
PUHZZRP71VHA
PEAD-RP100JA(L)Q
PEAD-RP125JA(L)Q
PEAD-RP140JA(L)Q
3.24 (3.26)
12.5
13.4
13.4
5.0
6.1
7.1
9.5
9.5
12.5
3.6
886 (873)
980 (956)
991 (976)
317 (301)
366 (351)
446 (428)
593 (583)
602 (592)
875 (858)
228 (211)
5.5 (5.8)
5.8 (6.1)
5.6 (5.7)
5.6 (5.7)
5.5 (5.6)
4.9 (5.0)*4
4.8 (4.9)*4
4.7 (4.8)*4
5.0 (5.1)*4
5.6 (6.0)
A (A+)
A+ (A++)
A+ (A+)
A+ (A+)
A (A+)
A+ (A+)
6.0
7.0
8.0
11.2
11.2
4.1
14.0
14.0
16.0
16.0
2.5 - 7.3
2.8 - 8.2
3.5 - 10.2
4.5 - 14.0
4.5 - 14.0
1.6 - 5.2
5.0 - 16.0
5.0 - 16.0
5.7 - 18.0
5.7 - 18.0
1.50
1.79
2.03
2.60
2.60
0.95
3.51
3.51
4.07
4.07
3.99
3.99
3.93
3.93
3.8
4.4
4.9
7.8
7.8
2.4
9.3
9.3
10.6
10.6
3.8 (10C)
4.4 (10C)
4.9 (10C)
7.8 (10C)
7.8 (10C)
2.4 (10C)
9.3 (10C)
9.3 (10C)
10.6 (10C) 10.6 (10C)
3.8 (10C)
4.4 (10C)
4.9 (10C)
7.8 (10C)
7.8 (10C)
2.4 (10C)
9.3 (10C)
9.3 (10C)
10.6 (10C) 10.6 (10C)
3.7 (11C)
2.8 (20C)
3.7 (20C)
5.8 (20C)
5.8 (20C)
2.2 (11C)
7.0 (20C)
7.0 (20C)
7.9 (20C)
7.9 (20C)
0
0
0
0
0
0
0
0
0
0
1231
1513
1762
2627
839
3370
3370
3763
3763
2627
4.3
4.1
3.9
4.2
4.0
3.9*4
3.9*4
4.0*4
4.0*4
4.2
A+
A+
A
A+
A+
A+
21.0
14.4
20.6
29.2
14.1
10.7
29.3
12.3
30.8
15.8
0.09 (0.07) / 0.07 0.11(0.09) / 0.09 0.12 (0.10) / 0.10 0.17 (0.15) / 0.15 0.25 (0.23) / 0.23 0.25 (0.23) / 0.23 0.36 (0.34) / 0.34 0.36 (0.34) / 0.34 0.39 (0.37) / 0.37 0.39 (0.37) / 0.37
1.07
1.39
1.62
1.97
2.65
2.65
2.76
2.76
2.78
2.78
250 - 900 - 732
250 - 1100 - 732
250 - 1400 - 732
250 - 1600 - 732
26 (25)
28 (27)
33 (32)
33 (32)
41 (40)
41 (40)
43 (42)
43 (42)
47 (46)
47 (46)
10.0 - 12.0 - 14.0 12.0 - 14.5 - 17.0 14.5 - 18.0 - 21.0 17.5 - 21.0 - 25.0 24.0 - 29.0 - 34.0 24.0 - 29.0 - 34.0 29.5 - 35.5 - 42.0 29.5 - 35.5 - 42.0 32.0 - 39.0 - 46.0 32.0 - 39.0 - 46.0
35 / 50 / 70 / 100 / 150
23 - 27 - 30
26 - 31 - 35
25 - 29 - 33
26 - 30 - 34
29 - 34 - 38
29 - 34 - 38
33 - 36 - 40
33 - 36 - 40
34 - 38 - 43
34 - 38 - 43
52
57
55
58
61
61
65
65
66
66
630 - 809 - 300
943 - 950 - 330 (+30)
1338 - 1050 - 330 (+40)
43
46
67
67
116
123
116
125
118
131
45.0
45.0
55.0
55.0
110.0
110.0
120.0
120.0
120.0
120.0
45.0
45.0
55.0
55.0
110.0
110.0
120.0
120.0
120.0
120.0
44
44
47
47
49
49
50
50
50
50
46
46
48
48
51
51
52
52
52
52
65
65
67
67
69
69
70
70
70
70
13.0
13.0
19.0
19.0
26.5
8.0
26.5
9.5
28.0
13.0
16
16
25
25
32
16
32
16
40
16
6.35 / 12.7
6.35 / 12.7
9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88
50
50
50
50
75
75
75
75
75
75
30
30
30
30
30
30
30
30
30
30
15 ~ +46
15 ~ +46
15 ~ +46
15 ~ +46
15 ~ +46
15 ~ +46
15 ~ +46
15 ~ +46
15 ~ +46
15 ~ +46
11 ~ +21
11 ~ +21
20 ~ +21
20 ~ +21
20 ~ +21
20 ~ +21
20 ~ +21
20 ~ +21
20 ~ +21
20 ~ +21
Refrigerant
Power Source
Supply Outdoor (V/Phase/Hz)
kW
Rated
Cooling Capacity
kW
Min - Max
kW
Rated
Total Input
EER*5
EEL Rank
kW
Design Load
kWh/a
Annual Electricity Consumption*2
SEER*5
Energy Efficiency Class
kW
Rated
Heating Capacity
(Average
kW
Min - Max
Season) Total Input
kW
Rated
COP*5
EEL Rank
kW
Design Load
Declared Capacity at reference design temperature kW
kW
at bivalent temperature
kW
at operation limit temperature
kW
Back Up Heating Capacity
kWh/a
Annual Electricity Consumption*2
SCOP*5
Energy Efficiency Class
A
Operating Current (max)
kW
Indoor Input [Cooling / Heating] Rated
Unit
A
Operating Current (max)
mm
Dimensions <Panel>
HWD
kg
Weight <Panel>
m3/min
Air Volume [Lo-Mid-Hi]
Pa
External Static Pressure
dB(A)
Sound Level (SPL) [Lo-Mid-Hi]
dB(A)
Sound Level (PWL)
mm
Outdoor Dimensions
HWD
Unit
kg
Weight
m3/min
Air Volume
Cooling
m3/min
Heating
dB(A)
Sound Level (SPL)
Cooling
dB(A)
Heating
dB(A)
Sound Level (PWL)
Cooling
A
Operating Current (max)
A
Breaker Size
mm
Ext.
Diameter
Liquid / Gas
Piping Max. Length
m
Out-In
m
Max. Height
Out-In
C
Guaranteed Operating Range
Cooling*3
[Outdoor]
C
Heating
*1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance
contains a refrigerant fluid with a GWP equal to 1975. This means that if 1kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1kg of CO2, over a period
of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
*2 Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
*3 Optional air protection guide is required where ambient temperature is lower than 5C. *4 SEER/SCOP values are measured based on EN14825. These values are reference purpose only.
*5 EER/COP and SEER/SCOP for RP35~71 are measured at ESP 35Pa, for RP100 at ESP 37Pa, for RP125/140 at ESP 50Pa. *6 Only the JAQ model is targeted for EUROVENT registration.
PEDZ-P JA SERIES
PUHZ
PUHZ
PUHZ
PUHZ
SUZ
PUHZ
Wi-Fi
Interface
STANDARD INVERTER
Optional
Optional
*5
PUHZ
JAQ
Optional
Optional
Optional
Optional
PUHZ
Optional
Type
Indoor Unit
Outdoor Unit
75
PEADRP50JA(L)Q
PEADRP60JA(L)Q
PEADRP71JA(L)Q
PEAD-RP100JA(L)Q
PEAD-RP125JA(L)Q
PEAD-RP140JA(L)Q
PUHZPUHZPUHZPUHZPUHZPUHZP100VHA4
P100YHA2
P125VHA3
P125YHA
P140VHA3
P140YHA
R410A*1
Outdoor power supply
VA5 VHA3 VHA4:230 / Single / 50, YHA YHA2:400 / Three / 50
4.9
7.1
9.4
9.4
12.3
12.3
13.6
13.6
3.6
5.7
2.3 - 5.6
2.8 - 8.1
4.9 - 11.2
4.9 - 11.2
5.5 - 14.0
5.5 - 14.0
5.5 - 15.0
5.5 - 15.0
1.4 - 3.9
2.3 - 6.3
1.050 (1.030) 1.480 (1.460) 1.670 (1.650) 2.080 (2.060) 3.120 (3.102) 3.120 (3.102) 4.220 (4.200) 4.220 (4.200) 4.520 (4.500) 4.520 (4.500)
2.91 (2.93)
2.91 (2.93)
3.01 (3.02)
3.01 (3.02)
C
C
B
B
4.9
7.1
9.4
9.4
3.6
5.7
318 (301)
429 (413)
716 (694)
716 (694)
229 (213)
351 (335)
5.4 (5.7)
5.8 (6.0)
4.6 (4.7)
4.6 (4.7)
5.5 (5.9)
5.6 (5.9)
+
+
+
+
+
+
A (A )
A (A )
B
B
A (A )
A (A )
5.9
8.0
11.2
11.2
14.0
14.0
16.0
16.0
4.1
7.0
1.7 - 7.2
2.6 - 10.2
4.5 - 12.5
4.5 - 12.5
5.0 - 16.0
5.0 - 16.0
5.0 - 18.0
5.0 - 18.0
1.7 - 5.0
2.5 - 8.0
1.620
2.040
3.103
3.103
3.870
3.870
4.430
4.430
1.110
1.930
3.62
3.62
3.61
3.61
A
A
A
A
4.4
6.0
8.0
8.0
2.8
4.5
3.9 (10C)
5.3 (10C)
6.3 (10C)
6.3 (10C)
2.5 (10C)
4.1 (10C)
3.9 (7C)
5.3 (7C)
7.1 (7C)
7.1 (7C)
2.5 (7C)
4.1 (7C)
3.9 (10C)
5.3 (10C)
5.0 (15C)
5.0 (15C)
2.5 (10C)
4.1 (10C)
0.5
0.7
1.7
1.7
0.3
0.5
1466
2153
2945
2945
980
1569
4.2
3.9
3.8
3.8
4.0
4.0
A+
A
A
A
A+
A+
13.4
18.1
30.7
15.7
30.8
15.8
32.3
15.8
9.3
15.6
0.09(0.07) / 0.07 0.11(0.09)/0.09 0.12(0.10) /0.10 0.17(0.15) / 0.15 0.25(0.23)/0.23 0.25(0.23)/0.23 0.36(0.34)/0.34 0.36(0.34)/0.34 0.39(0.37)/0.37 0.39(0.37)/0.37
1.07
1.39
1.62
1.97
2.65
2.65
2.76
2.76
2.78
2.78
250 - 900 - 732
250 - 1100 - 732
250 - 1400 - 732
250 - 1600 - 732
26 (25)
28 (27)
33 (32)
33 (32)
41 (40)
41 (40)
43 (42)
43 (42)
47 (46)
47 (46)
10.0 - 12.0 - 14.0 12.0 - 14.5 - 17.0 14.5 - 18.0 - 21.0 17.5 - 21.0 - 25.0 24.0 - 29.0 - 34.0 24.0 - 29.0 - 34.0 29.5 - 35.5 - 42.0 29.5 - 35.5 - 42.0 32.0 - 39.0 - 46.0 32.0 - 39.0 - 46.0
35 / 50 / 70 / 100 / 150
23 - 27 - 30
26 - 31 - 35
25 - 29 - 33
26 - 30 - 34
29 - 34 - 38
29 - 34 - 38
33 - 36 - 40
33 - 36 - 40
34 - 38 - 43
34 - 38 - 43
52
57
55
58
61
61
65
65
66
66
943 - 950 - 330(+30)
1350 - 950 - 330(+30)
550 - 800 - 285
880 - 840 - 330
35
54
50
53
75
77
99
101
99
101
36.3
44.6
40.9
50.1
60.0
60.0
100.0
100.0
100.0
100.0
34.8
44.6
49.2
48.2
60.0
60.0
100.0
100.0
100.0
100.0
49
52
55
55
50
50
51
51
52
52
50
52
55
55
54
54
55
55
56
56
62
65
65
69
70
70
71
71
73
73
8.2
12.0
14.0
16.1
28.0
13.0
28.0
13.0
29.5
13.0
16
20
20
20
32
16
32
16
40
16
6.35 / 9.52
6.35 / 12.7
6.35 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88
20
30
30
30
50
50
50
50
50
50
12
30
30
30
30
30
30
30
30
30
10 ~ +46
15 ~ +46
15 ~ +46
15 ~ +46
15 ~ +46*3 15 ~ +46*3 15 ~ +46*3 15 ~ +46*3 15 ~ +46*3 15 ~ +46*3
10 ~ +24
10 ~ +24
10 ~ +24
10 ~ +24
15 ~ +21
15 ~ +21
15 ~ +21
15 ~ +21
15 ~ +21
15 ~ +21
SUZ-KA35VA5 SUZ-KA50VA5 SUZ-KA60VA5 SUZ-KA71VA5
Refrigerant
Power Source
Supply Outdoor (V/Phase/Hz)
kW
Rated
Cooling Capacity
kW
Min - Max
kW
Rated
Total Input
EER*4
EEL Rank
kW
Design Load
kWh/a
Annual Electricity Consumption*2
SEER*4
Energy Efficiency Class
kW
Rated
Heating Capacity
(Average
kW
Min - Max
Season) Total Input
kW
Rated
COP*4
EEL Rank
kW
Design Load
Declared Capacity at reference design temperature kW
kW
at bivalent temperature
kW
at operation limit temperature
kW
Back Up Heating Capacity
kWh/a
Annual Electricity Consumption*2
SCOP*4
Energy Efficiency Class
A
Operating Current (max)
kW
Indoor Input [Cooling / Heating] Rated
Unit
A
Operating Current (max)
mm
Dimensions <Panel>
HWD
kg
Weight <Panel>
m3/min
Air Volume [Lo-Mid-Hi]
Pa
External Static Pressure
dB(A)
Sound Level (SPL) [Lo-Mid-Hi]
dB(A)
Sound Level (PWL)
mm
Outdoor Dimensions
HWD
Unit
kg
Weight
m3/min
Air Volume
Cooling
m3/min
Heating
dB(A)
Sound Level (SPL)
Cooling
dB(A)
Heating
dB(A)
Sound Level (PWL)
Cooling
A
Operating Current (max)
A
Breaker Size
mm
Ext.
Diameter
Liquid / Gas
Piping Max. Length
m
Out-In
m
Max. Height
Out-In
C
Guaranteed Operating Range
Cooling
[Outdoor]
C
Heating
*1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance
contains a refrigerant fluid with a GWP equal to 1975. This means that if 1kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1kg of CO2, over a period
of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
*2 Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
*3 Optional air protection guide is required where ambient temperature is lower than 5C. *4 EER/COP and SEER/SCOP for RP35~71 are measured at ESP 35Pa, for RP100 at ESP 37Pa, for RP125/140 at ESP 50Pa.
*5 Only the JAQ model is targeted for EUROVENT registration.
PEA
SERIES
PEA-RP200/250/400/500GAQ
For elegance and style, the PEA Series compliments the room environment with
an aesthetically pleasing ceiling installation and a vast line-up of performance
functions. Long pipe work installation is supported, increasing freedom in the
placement of indoor units.
Power Inverter
Connection
Standard Inverter
Connection
200
100m
30m
70m
30m
250
100m
30m
70m
30m
400
100m
30m
70m
30m
500
100m
30m
70m
30m
Wide-ranging Line-up from 2050kW Extensive Array of Choices to Match Building Size
[System Image]
PEA-RP200/250GAQ
D
E
F
PUHZ-200, 250
L1 L2 L3 N
1 2
PEA-200, 250
L1 L2 L3 N
S1 S2 S3
S1 S2 S3
I
I
PEA-RP400/500GAQ
D
E (No.1 Outdoor)
PUHZ-200, 250
PEA-400, 500
1 2
(TB4-1) (TB4-2)
L1 L2 L3 N
S1 S2 S3
S1 S2 S3
L1 L2 L3 N
S1 S2 S3
(No.2 Outdoor)
PUHZ-200, 250
L1 L2 L3 N
S1 S2 S3
A
B
C
D
E
F
G
H
I
A
B
C
D
E
F
G
H
1
C
Power supply
Earth leakage breaker
Circuit breaker or local switch
LCD remote controller
Outdoor unit
Indoor unit
Power cable wiring
Indoor/Outdoor connection wiring
Grounding
Outdoor unit
Indoor unit
Main remote controller
Subordinate remote controller
Standard (Refrigerant address = 00)
Refrigerant address = 01
Refrigerant address = 02
Refrigerant address = 15
LINE-UP
Indoor Unit
Outdoor Unit
Power
Inverter
Series
PEA-RP200/250/400/500GAQ
PUHZ-ZRP200/250
Remote Controller
Standard
Inverter
Series
PUHZ-P200/250
Optional
Optional
76
PEZ-RP SERIES
Optional
Wi-Fi
POWER INVERTER
Interface
Optional
Optional
Optional
Type
PEA-RP200GAQ
Indoor Unit
Outdoor Unit
PUHZ-ZRP200YKA
Capacity
Total Input
EER
Rated
Min - Max
Rated
kW
19.0
22.0
38.0
44.0
kW
kW
9.0 - 22.4
11.2 - 27.0
18.0 - 44.8
22.4 - 54.0
6.46
8.31
12.47
17.10
2.94
2.65
3.05
2.57
EEL Rank
Heating Capacity
(Average
Season)
Total Input
COP
Rated
kW
22.4
27.0
44.8
54.0
Min - Max
Rated
kW
kW
9.5 - 25.0
12.5 - 31.0
18.0 - 50.0
25.0- 62.0
6.94
8.94
13.43
18.36
3.23
3.02
3.34
2.94
21.0
23.3
41.8
47.4
kW
A
1.000
1.180
1.550
2.840
2.0
2.3
3.8
mm
kg
m3/min
Pa
70
77
130
133
52.0 - 65.0
64.0 - 80.0
120.0
160.0
EEL Rank
Operating Current (max)
Input [Cooling / Heating] Rated
Indoor
Unit
Operating Current (max)
Dimensions
HxWxD
Weight
Air Volume [Lo-Mid-Hi]
External Static Pressure
Sound Level (SPL) [Lo-Mid-Hi]
dB(A)
dB(A)
HxWxD
150
150
150
49 - 52
52*2
53*2
15
15
15
1338 - 1050 - 330(+40)
15
1338 - 1050 - 330(+40)
kg
135
135
135
135
140
140
140
140
Heating
m /min
140
140
140
140
Cooling
Heating
dB(A)
59
59
59
59
dB(A)
dB(A)
62
62
62
62
77
77
77
77
A
A
mm
19.0
21.0
19.0
21.0
150
m3/min
3
Cooling
Diameter
Max. Length
Max. Height
5.4
595 - 1947 - 764
48 - 51
mm
Cooling
Ext.
Piping
PUHZ-ZRP250YKA x 2
R410A *1
Refrigerant
Source
Power
Supply Outdoor (V/Phase/Hz)
Cooling
PEA-RP500GAQ
PUHZ-ZRP200YKA x 2
PUHZ-ZRP250YKA
m
m
32
32
32
32
9.52 / 25.4
12.7 / 25.4
9.52 / 25.4
12.7 / 25.4
100
100
100
100
30
30
30
30
Cooling *3
-15 ~ +46
-15 ~ +46
-15 ~ +46
-15 ~ +46
Heating
-20 ~ +21
-20 ~ +21
-20 ~ +21
-20 ~ +21
C
C
*1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance
contains a refrigerant fluid with a GWP equal to 1975. This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1 kg of CO2, over a
period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
*2 Energy consumption based on standard test results.Actual energy consumption will depend on how the appliance is used and where it is located.
*3 Optional air protection guide is required where ambient temperature is lower than -5C.
*4 SEER/SCOP values are measured based on EN14825. These values are reference purpose only.
PEZ-P SERIES
STANDARD INVERTER
Interface
Optional
Optional
Type
Indoor Unit
Outdoor Unit
Refrigerant
Source
Power
Supply Outdoor (V/Phase/Hz)
Cooling Capacity
Rated
Total Input
EER
Heating Capacity
(Average
Season)
Total Input
COP
PUHZ-P200YKA
PUHZ-P250YKA
PUHZ-P200YKA x 2
PEA-RP500GAQ
PUHZ-P250YKA x 2
400 / Three / 50
Min - Max
Rated
EEL Rank
Rated
Min - Max
Rated
PEA-RP200GAQ
R410A *1
Outdoor power supply
kW
kW
19.0
22.0
38.0
44.0
9.0 - 22.4
11.2 - 27.0
18.0 - 44.8
22.4 - 54.0
kW
6.64
8.71
12.83
17.90
2.86
2.53
2.96
2.46
22.4
27.0
44.8
54.0
9.5 - 25.0
12.5 - 31.0
18.0 - 50.0
25.0- 62.0
7.10
9.31
13.75
19.10
3.15
2.90
3.26
2.83
21.0
23.3
41.8
47.4
1.000
1.180
1.550
2.840
2.0
2.3
3.8
kW
kW
kW
EEL Rank
Outdoor Dimensions
Unit
Weight
Air Volume
Optional
Optional
Wi-Fi
HxWxD
Cooling
Heating
Cooling
Heating
Cooling
kW
A
mm
kg
m3/min
Pa
dB(A)
dB(A)
mm
kg
m3/min
m3/min
dB(A)
dB(A)
dB(A)
A
A
mm
m
m
5.4
595 - 1947 - 764
70
77
130
133
52.0 - 65.0
64.0 - 80.0
120.0
160.0
150
150
150
150
48 - 51
49 - 52
52*2
53*2
15
15
15
1338 - 1050 - 330(+40)
15
1338 - 1050 - 330(+40)
127
135
127
135
140
140
140
140
140
140
140
140
58
59
58
59
60
62
60
62
78
77
78
77
19.0
21.0
19.0
21.0
32
32
32
32
9.52 / 25.4
12.7 / 25.4
9.52 / 25.4
12.7 / 25.4
70
70
70
30
30
30
30
70
-15 ~ +46
-15 ~ +46
-15 ~ +46
-15 ~ +46
-20 ~ +21
-20 ~ +21
-20 ~ +21
-20 ~ +21
C
C
*1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance
contains a refrigerant fluid with a GWP equal to 1975. This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1 kg of CO2, over a
period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
*2 Energy consumption based on standard test results.Actual energy consumption will depend on how the appliance is used and where it is located.
*3 Optional air protection guide is required where ambient temperature is lower than -5C.
*4 SEER/SCOP values are measured based on EN14825. These values are reference purpose only.
77
PKA-RP35/50HAL
PKA
PKA-RP60/71/100KAL
SERIES
The compact, wall-mounted indoor units offer the convenience of simple installation,
and a large product line-up (RP35-RP100 models) ensures a best-match solution.
Designed for highly efficient energy savings, the PKA Series is the answer to your
air conditioning needs.
PKA-RP GAL
PKA-RP HAL
PKA-RP FAL
PKA-RP KAL
PKA-RP35/50HAL
*Compared to PKA-RP35/50GAL
230mm DOWN*
PKA-RP60/71KAL
*Compared to PKA-RP60/71FAL
510mm DOWN*
PKA-RP100KAL
*Compared to PKA-RP100FAL
5.7
3.9
SCOP
A
PKA-RP35HAL
PUHZ-ZRP35VKA
SEER
A
5.3
SCOP
A+
SEER
A++
6.3
4.0
PKA-RP50HAL
PUHZ-ZRP50VKA
SCOP
A+
SEER
A++
6.5
SCOP
A+
SEER
A++
6.1
4.3
4.2
PKA-RP60KAL
PUHZ-ZRP60VHA
PKA-RP71KAL
PUHZ-ZRP71VHA
SCOP
A++
4.0
PKA-RP100KAL
PUHZ-ZRP100VKA2
SEER
A+
6.0
SCOP
A+
4.0
PKA-RP100KAL
PUHZ-ZRP100YKA2
Main Functions
Drain pump
800mm
Indoor unit
Night Setback
Energy- saving Mode
Multi Language
Weekly Timer
Refrigerant Leak Check
For details, please refer to pages 25-28.
78
SERIES SELECTION
35-140
100-250
35-71
35-71
Heat Caulking
Fixing Method
Joint Lap
Indoor Unit
DC Scroll
DC Fan Motor
Vector-Wave
Grooved Piping
Outdoor Unit
For Single
PUHZ-ZRP35/50
PKA-RP35/50HAL
PUHZ-ZRP60/71
PUHZ-ZRP100
PUHZ-ZRP71
PUHZ-ZRP100/125/140/200/250
For Multi
(Twin/Triple/Quadruple)
PKA-RP60/71/100KAL
Remote Controller
Optional ()
Optional ()
100-250
100-140
200/250
DC Rotary
DC Scroll
100-250
100-140
Vector-Wave
DC Fan Motor
Grooved Piping
Outdoor Unit
For Single
PUHZ-P100
PKA-RP35/50HAL
For Multi
(Twin/Triple/Quadruple)
PKA-RP60/71/100KAL
PUHZ-P100
PUHZ-P125/140
PUHZ-P200/250
Remote Controller
Optional ()
Optional ()
() PAC-SH29TC-E is required (optional)
79
For Twin
For Single
50
60
71
100
125
140
200
250
71
100
125
140
For Triple
200
100x1
250
MSDD-50WR-E
MSDD-50TR-E
MSDD-50WR-E
140
200
250
For Quadruple
200
250
MSDF-1111R-E
MSDF-1111R-E
PKZ-RP SERIES
POWER INVERTER
60-140V/200/250
Optional
Optional
Optional
Optional
Optional
Optional
Wi-Fi
Please fill out the requested information
Please fill out the requested information
Interface
Optional
Optional
Optional
Type
Inverter Heat Pump
Indoor Unit
PKA-RP35HAL
PKA-RP50HAL
PKA-RP60KAL
PKA-RP71KAL
PKA-RP100KAL
Outdoor Unit
PUHZ-ZRP35VKA
PUHZ-ZRP50VKA
PUHZ-ZRP60VHA
PUHZ-ZRP71VHA
PUHZ-ZRP100VKA2
PUHZ-ZRP100YKA2
1
Refrigerant
R410A*
Outdoor power supply
Power Source
Supply Outdoor (V/Phase/Hz)
VKA VHA:230 / Single / 50, YKA:400 / Three / 50
9.5
9.5
7.1
6.1
4.6
kW
3.6
Rated
Cooling Capacity
4.9 - 11.4
4.9 - 11.4
3.3 - 8.1
2.7 - 6.7
2.3 - 5.6
kW
1.6 - 4.5
Min - Max
2.40
2.40
1.80
1.60
1.41
kW
0.94
Rated
Total Input
EER
EEL Rank
9.5
9.5
7.1
6.1
4.6
kW
3.6
Design Load
550
539
381
336
304
kWh/a
221
Annual Electricity Consumption*2
6.0
6.1
6.5
6.3
5.3
5.7
SEER
A+
A++
Energy Efficiency Class
A++
A++
A
A+
11.2
11.2
8.0
7.0
5.0
kW
4.1
Rated
Heating Capacity
(Average
4.5 - 14.0
4.5 - 14.0
3.5 - 10.2
2.8 - 8.2
2.5 - 7.3
kW
1.6 - 5.2
Min - Max
Season) Total Input
3.04
3.04
2.19
1.96
1.50
kW
1.07
Rated
COP
EEL Rank
7.8
7.8
4.7
4.4
3.3
kW
2.4
Design Load
7.8 (10C)
7.8 (10C)
4.7 (10C)
4.4 (10C)
3.3 (10C)
2.4 (10C)
Declared Capacity at reference design temperature kW
7.8 (10C)
7.8 (10C)
4.7 (10C)
4.4 (10C)
3.3 (10C)
kW
2.4 (10C)
at bivalent temperature
5.8 (20C)
5.8 (20C)
3.5 (20C)
2.8 (20C)
3.2 (11C)
kW
2.2 (11C)
at operation limit temperature
0
0
0
0
0
kW
0
Back Up Heating Capacity
2608
2608
1532
1473
1160
kWh/a
847
Annual Electricity Consumption*2
4.1
4.1
4.3
4.2
4.0
3.9
SCOP
A+
Energy Efficiency Class
A+
A+
A+
A+
A
8.6
27.1
19.4
19.4
A
13.4
Operating Current (max)
13.4
0.08
0.08
0.06
0.06
kW
0.04
Indoor Input
0.04
Rated
Unit
0.57
0.57
0.43
0.43
A
0.4
0.4
Operating Current (max)
mm
Dimensions <Panel> H W D
295 - 898 - 249
365 - 1170 - 295
21
21
21
21
kg
13
13
Weight <Panel>
20 - 23 - 26
20 - 23 - 26
18 - 20 - 22
18 - 20 - 22
m3/min
9 - 10.5 - 12
9 - 10.5 - 12
Air Volume [Lo-Mid-Hi]
41 - 45 - 49
41 - 45 - 49
39 - 42 - 45
39 - 42 - 45
dB(A)
36 - 40 - 43
36 - 40 - 43
Sound Level (SPL) [Lo-Mid-Hi]
65
65
64
64
dB(A)
60
60
Sound Level (PWL)
mm
630 - 809 - 300
943 - 950 - 330 (+30)
1338 - 1050 - 330 (+40)
Outdoor Dimensions
HWD
Unit
123
116
67
67
kg
46
43
Weight
110.0
110.0
55.0
55.0
m3/min
45.0
45.0
Air Volume
Cooling
110.0
110.0
55.0
55.0
m3/min
45.0
45.0
Heating
49
49
47
47
dB(A)
44
44
Sound Level (SPL) Cooling
51
51
48
48
dB(A)
46
46
Heating
69
69
67
67
dB(A)
65
65
Sound Level (PWL) Cooling
8.0
26.5
19.0
19.0
A
13.0
13.0
Operating Current (max)
16
32
25
25
A
16
16
Breaker Size
9.52 / 15.88
9.52 / 15.88
9.52 / 15.88
mm
9.52 / 15.88
Ext.
6.35 / 12.7
6.35 / 12.7
Diameter
Liquid / Gas
Piping Max. Length
75
75
50
m
50
50
50
Out-In
30
30
30
m
30
30
30
Max. Height
Out-In
15 ~ +46
15 ~ +46
15 ~ +46
C
15 ~ +46
Guaranteed Operating Range Cooling*3
15 ~ +46
15 ~ +46
[Outdoor]
20 ~ +21
20 ~ +21
20 ~ +21
C
20 ~ +21
11 ~ +21
11 ~ +21
Heating
*1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance
contains a refrigerant fluid with a GWP equal to 1975. This means that if 1kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1kg of CO2, over a period
of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
*2 Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
*3 Optional air protection guide is required where ambient temperature is lower than 5C. *4 SEER/SCOP values are measured based on EN14825. These values are reference purpose only.
PKZ-P SERIES
STANDARD INVERTER
Wi-Fi
Interface
Optional
Optional
Optional
Optional
Optional
Optional
Optional
Optional
Optional
Type
Inverter Heat Pump
Indoor Unit
PKA-RP100KAL
Outdoor Unit
PUHZ-P100VHA4
PUHZ-P100YHA2
Refrigerant
R410A*1
Outdoor power supply
Power Source
Supply Outdoor (V/Phase/Hz)
230 / Single / 50
400 / Three / 50
9.4
9.4
kW
Rated
Cooling Capacity
4.9 - 11.2
kW
4.9 - 11.2
Min - Max
3.120
kW
3.120
Total Input
Rated
9.4
kW
9.4
Design Load
686
kWh/a
686
Annual Electricity Consumption*2
4.8
4.8
SEER
Energy Efficiency Class
B
B
11.2
kW
11.2
Rated
Heating Capacity
(Average
4.5 - 12.5
kW
4.5 - 12.5
Min - Max
Season) Total Input
3.490
kW
3.490
Rated
7.0
kW
7.0
Design Load
5.6 (10C)
5.6 (10C)
Declared Capacity at reference design temperature kW
kW
6.2 (7C)
6.2 (7C)
at bivalent temperature
kW
4.5 (15C)
4.5 (15C)
at operation limit temperature
kW
1.4
1.4
Back Up Heating Capacity
kWh/a
2579
2579
Annual Electricity Consumption*2
3.8
3.8
SCOP
Energy Efficiency Class
A
A
A
13.6
Operating Current (max)
28.6
kW
0.08
Indoor Input
0.08
Rated
Unit
A
0.57
0.57
Operating Current (max)
mm
365 - 1170 - 295
Dimensions <Panel> H W D
kg
21
21
Weight <Panel>
m3/min
20 - 23 - 26
20 - 23 - 26
Air Volume [Lo-Mid-Hi]
dB(A)
41 - 45 - 49
41 - 45 - 49
Sound Level (SPL) [Lo-Mid-Hi]
dB(A)
65
65
Sound Level (PWL)
mm
Outdoor Dimensions
943 - 950 - 330 (+30)
HWD
Unit
kg
77
75
Weight
m3/min
60.0
60.0
Air Volume
Cooling
m3/min
60.0
60.0
Heating
dB(A)
50
50
Sound Level (SPL) Cooling
dB(A)
54
54
Heating
dB(A)
70
70
Sound Level (PWL) Cooling
A
13.0
28.0
Operating Current (max)
A
16
32
Breaker Size
mm
Ext.
9.52 / 15.88
9.52 / 15.88
Diameter
Liquid / Gas
Piping Max. Length
m
50
50
Out-In
m
30
30
Max. Height
Out-In
C
Guaranteed Operating Range Cooling*3
15 ~ +46
15 ~ +46
[Outdoor]
C
15 ~ +21
15 ~ +21
Heating
*1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance
contains a refrigerant fluid with a GWP equal to 1975. This means that if 1kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1kg of CO2, over a period
of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
*2 Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
*3 Optional air protection guide is required where ambient temperature is lower than 5C. *4 SEER/SCOP values are measured based on EN14825. These values are reference purpose only.
80
PCA-KA
PCA-RP35/50/60/71/100/125/140KAQ
SERIES
A stylish new indoor unit design and airflow settings for both high- and low-ceiling
interiors expand installation possibilities. Together with exceptional energy-saving
performance, these units are the solution to diversified air conditioning needs.
PCA-GA
PCA-KAQ
ErP Lot 10 Compliant with High Energy-efficiency Achieving SEER/SCOP Rank A, A+ and A++
A direct-current (DC) fan motor is isntalled in the indoor unit, increasing the seasonal energy efficiency of newly designed Power Inverter series
(PUHZ-ZRP) and resulting in the full capacity models comply ErP Lot 10 with energy ranking A+/A++ for cooling and A/A+ for heating. This contribute to an impressive reduction in the cost of annual electricity.
SEER
A++
6.1
SCOP
A+
4.1
SEER
A+
6.0
SCOP
A+
4.2
SEER
A++
6.2
SEER
A++
SCOP
A+
6.6
SCOP
A+
4.3
4.3
SEER
A+
6.0
SCOP
A
SEER
A+
5.9
SCOP
A
3.9
3.9
5.2
5.2
4.2
5.3
4.2
4.4
5.2
4.4
PCA-RP35KAQ PCA-RP50KAQ PCA-RP60KAQ PCA-RP71KAQ PCA-RP100KAQ PCA-RP100KAQ PCA-RP125KAQ PCA-RP125KAQ PCA-RP140KAQ PCA-RP140KAQ
PUHZ-ZRP35VKA PUHZ-ZRP50VKA PUHZ-ZRP60VHA PUHZ-ZRP71VHA PUHZ-ZRP100VKA2 PUHZ-ZRP100YKA2 PUHZ-ZRP125VKA2 PUHZ-ZRP125YKA2 PUHZ-ZRP140VKA2 PUHZ-ZRP140YKA2
For products with capacity over 10.0kW, SEER/SCOP values are measured based on EN14825. These values are for reference purposes only.
Outside-air Intake
The pumping height of the optional drain pump has been increased from 400mm to 600mm,
expanding flexibility in choosing
unit location during installation
work.
Ceiling surface
Drainage outlet
can be 600mm
above ceiling
surface
PCA-RP100-140KAQ
PCA-RP60/71KAQ
PCA-RP35/50KAQ
150
200
250
300
Units are equipped with high- and low-ceiling operation modes that
make it possible to switch the airflow volume to match room height.
The ability to choose the optimum airflow volume makes it possible
to optimize the breezy sensation felt throughout the room.
Strong
Start of cooling/heating
81
Drain pump
installation possible
Gentle
Capacity
High
ceiling
Standard
ceiling
Low
ceiling
35
3.5m
2.7m
2.5m
50
3.5m
2.7m
2.5m
60
3.5m
2.7m
2.5m
71
3.5m
2.7m
2.5m
100
4.2m
3.0m
2.6m
125
4.2m
3.0m
2.6m
140
4.2m
3.0m
2.6m
PCA-HA
PCA-RP71HAQ
SERIES
Standard features include a strong carbon-black stainless steel body and built-in
oil mist filter to prevent oil from getting into the unit providing a comfortable air
conditioning environment in kitchens that use open-flame cooking.
Easy Maintenance
Even for Cleaning the Fan
Front cover
Flexible Duct
(Procured locally)
Duct Flange
(200, Optional PAC-SF28OF-E)
82
SERIES SELECTION
35-71
35-140
100-250
35-71
Heat Caulking
Fixing Method
Joint Lap
Indoor Unit
DC Fan Motor
DC Scroll
Outdoor Unit
Vector-Wave
Grooved Piping
Remote Controller
For Single
PUHZ-ZRP35/50
PUHZ-ZRP60/71
PUHZ-ZRP100/125/140
Optional
For Multi
(Twin/Triple/Quadruple)
PCA-RP35/50/60/71/100/125/140KAQ
Optional
Optional
PUHZ-ZRP100/125/140/200/250
Indoor Unit
50-71
100-250
71-140
200/250
Joint Lap
DC Rotary
DC Scroll
50-140
100-250
50-71
Heat Caulking
Fixing Method
Grooved Piping
Vector-Wave
DC Fan Motor
Remote Controller
Outdoor Unit
For Single
SUZ-KA35
SUZ-KA50/60/71
PUHZ-P100
PUHZ-P125/140
Optional
For Multi
(Twin/Triple/
Quadruple)
PCA-RP35/50/60/71/100/125/140KAQ
PUHZ-P100
PUHZ-P125/140
Optional
Optional
PUHZ-P200/250
For Twin
For Single
50
60
71
100
125
140
200
250
71
100
125
For Quadruple
For Triple
140
200
250
140
200
250
200
250
35x2 50x2 60x2 71x2 100x2 125x2 50x3 60x3 71x3 50x4 60x4
MSDD-50WR-E
MSDD-50TR-E
MSDF-1111R-E
MSDT-111R-E
50x2 60x2 71x2 100x2 125x2 50x3 60x3 71x3 50x4 60x4
MSDD-50TR-E
MSDD-50WR-E
MSDF-1111R-E
MSDT-111R-E
SERIES SELECTION
71
100-250
71
71
Heat Caulking
Fixing Method
Joint Lap
Indoor Unit
DC Scroll
DC Fan Motor
Outdoor Unit
Vector-Wave
Grooved Piping
Remote Controller
For Single
PUHZ-ZRP71
Optional
Optional
Optional
PUHZ-ZRP140/250
83
For Twin
For Single
For Triple
For Quadruple
35
50
60
71
100
125
140
200
250
71
100
125
140
200
250
140
200
250
200
71x1
71x2
71x3
250
MSDD-50TR-E
MSDT-111R-E
71x2
71x3
MSDD-50TR-E
MSDT-111R-E
PCZ-RP KA SERIES
POWER INVERTER
Optional
Optional
60-140V/200/250
Wi-Fi
Interface
Optional
Type
Indoor Unit
Optional
Optional
Optional
Optional
Optional
Outdoor Unit
PCARP50KAQ
PCARP60KAQ
PCARP71KAQ
PUHZZRP50VKA
PUHZZRP60VHA
PUHZZRP71VHA
PCA-RP100KAQ
PCA-RP125KAQ
PCA-RP140KAQ
3.39
3.39
3.14
12.5
9.5
9.5
7.1
6.1
5.0
13.4
13.4
12.5
3.6
834
560
553
375
347
292
882
893
844
206
5.2*4
5.9
6.0
6.6
6.2
6.0
5.3*4
5.2*4
5.2*4
6.1
A+
A+
A++
A++
A+
A++
11.2
11.2
8.0
7.0
5.5
4.1
14.0
14.0
16.0
16.0
4.5 - 14.0
4.5 - 14.0
3.5 - 10.2
2.8 - 8.2
2.5 - 6.6
1.6-5.2
5.0 - 16.0
5.0 - 16.0
5.7 - 18.0
5.7 - 18.0
3.04
3.04
2.20
1.93
1.45
1.02
3.80
3.80
4.57
4.57
3.68
3.68
3.50
3.50
7.8
7.8
4.7
4.4
3.8
2.4
9.3
9.3
10.6
10.6
7.8 (10C)
7.8 (10C)
4.7 (10C)
4.4 (10C)
3.8 (10C)
2.4 (10C)
9.3 (10C)
9.3 (10C)
10.6 (10C) 10.6 (10C)
7.8 (10C)
7.8 (10C)
4.7 (10C)
4.4 (10C)
3.8 (10C)
2.4 (10C)
9.3 (10C)
9.3 (10C)
10.6 (10C) 10.6 (10C)
5.8 (20C)
5.8 (20C)
3.5 (20C)
2.8 (20C)
3.7 (11C)
2.2 (11C)
7.0 (20C)
7.0 (20C)
7.9 (20C)
7.9 (20C)
0
0
0
0
0
0
0
0
0
0
2837
2837
1519
1458
1257
815
3097
3097
3366
3366
3.9
3.9
4.3
4.3
4.2
4.1
4.2*4
4.2*4
4.4*4
4.4*4
A
A
A+
A+
A+
A+
8.7
27.2
19.4
19.4
13.4
13.3
27.3
10.3
28.9
13.9
0.09
0.09
0.06
0.06
0.05
0.04
0.11
0.11
0.14
0.14
0.65
0.65
0.42
0.39
0.37
0.29
0.76
0.76
0.90
0.90
230 - 960 - 680
230 - 1280 - 680
230 - 1600 - 680
36
36
32
32
25
24
38
38
39
39
10 - 11 - 12 - 14 10 - 11 - 13 - 15 15 - 16 - 17 - 19 16 - 17 - 18 - 20 22 - 24 - 26 - 28 22 - 24 - 26 - 28 23 - 25 - 27 - 29 23 - 25 - 27 - 29 24 - 26 - 29 - 32 24 - 26 - 29 - 32
31 - 33 - 36 - 39 32 - 34 - 37 - 40 33 - 35 - 37 - 40 35 - 37 - 39 - 41 37 - 39 - 41 - 43 37 - 39 - 41 - 43 39 - 41 - 43 - 45 39 - 41 - 43 - 45 41 - 43 - 45 - 48 41 - 43 - 45 - 48
63
63
62
60
60
60
65
65
68
68
630 - 809 - 300
943 - 950 - 330 (+30)
1338 - 1050 - 330 (+40)
123
116
67
67
46
43
116
125
118
131
110.0
110.0
55.0
55.0
45.0
45.0
120.0
120.0
120.0
120.0
110.0
110.0
55.0
55.0
45.0
45.0
120.0
120.0
120.0
120.0
49
49
47
47
44
44
50
50
50
50
51
51
48
48
46
46
52
52
52
52
69
69
67
67
65
65
70
70
70
70
8.0
26.5
19.0
19.0
13.0
13.0
9.5
28.0
13.0
26.5
16
32
25
25
16
16
16
40
16
32
9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88
6.35 / 12.7
6.35 / 12.7
75
75
50
50
50
50
75
75
75
75
30
30
30
30
30
30
30
30
30
30
15 ~ +46
15 ~ +46
15 ~ +46
15 ~ +46
15 ~ +46
15 ~ +46
15 ~ +46
15 ~ +46
15 ~ +46
15 ~ +46
20 ~ +21
20 ~ +21
20 ~ +21
20 ~ +21
11 ~ +21
11 ~ +21
20 ~ +21
20 ~ +21
20 ~ +21
20 ~ +21
Refrigerant
Power Source
Supply Outdoor (V/Phase/Hz)
kW
Rated
Cooling Capacity
kW
Min - Max
kW
Total Input
Rated
EER
EEL Rank
kW
Design Load
kWh/a
Annual Electricity Consumption*2
SEER
Energy Efficiency Class
kW
Rated
Heating Capacity
(Average
kW
Min - Max
Season) Total Input
kW
Rated
COP
EEL Rank
kW
Design Load
Declared Capacity at reference design temperature kW
kW
at bivalent temperature
kW
at operation limit temperature
kW
Back Up Heating Capacity
kWh/a
Annual Electricity Consumption*2
SCOP
Energy Efficiency Class
A
Operating Current (max)
kW
Indoor Input
Rated
Unit
A
Operating Current (max)
mm
Dimensions <Panel> H W D
kg
Weight <Panel>
m3/min
Air Volume [Lo-Mi2-Mi1-Hi]
dB(A)
Sound Level (SPL) [Lo-Mi2-Mi1-Hi]
dB(A)
Sound Level (PWL)
mm
Outdoor Dimensions
HWD
Unit
kg
Weight
m3/min
Air Volume
Cooling
m3/min
Heating
dB(A)
Sound Level (SPL) Cooling
dB(A)
Heating
dB(A)
Sound Level (PWL) Cooling
A
Operating Current (max)
A
Breaker Size
mm
Ext.
Diameter
Liquid / Gas
Piping Max. Length
m
Out-In
m
Max. Height
Out-In
C
Guaranteed Operating Range Cooling*3
[Outdoor]
C
Heating
*1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance
contains a refrigerant fluid with a GWP equal to 1975. This means that if 1kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1kg of CO2, over a period
of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
*2 Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
*3 Optional air protection guide is required where ambient temperature is lower than 5C. *4 SEER/SCOP values are measured based on EN14825. These values are reference purpose only.
PCZ-P KA SERIES
STANDARD INVERTER
PUHZ
PUHZ
Optional
Optional
PUHZ
PUHZ
SUZ
PUHZ
PUHZ
PUHZ
Wi-Fi
Interface
Optional
Optional
Optional
Optional
Optional
Optional
Optional
Type
Inverter Heat Pump
Indoor Unit
PCA-RP35KAQ PCA-RP50KAQ PCA-RP60KAQ PCA-RP71KAQ
PCA-RP100KAQ
PCA-RP125KAQ
PCA-RP140KAQ
Outdoor Unit
SUZ-KA35VA5 SUZ-KA50VA5 SUZ-KA60VA5 SUZ-KA71VA5 PUHZ-P100VHA4 PUHZ-P100YHA2 PUHZ-P125VHA3 PUHZ-P125YHA PUHZ-P140VHA3 PUHZ-P140YHA
1
Refrigerant
R410A*
Outdoor power supply
Power Source
Supply Outdoor (V/Phase/Hz)
VA5 VHA3 VHA4:230 / Single / 50, YHA YHA2:400 / Three / 50
3.6
5.0
5.7
9.4
kW
9.4
7.1
12.3
12.3
13.6
13.6
Rated
Cooling Capacity
1.4 - 3.9
2.3 - 5.6
2.3 - 6.3
4.9 - 11.2
kW
4.9 - 11.2
2.8 - 8.1
5.5 - 14.0
5.5 - 14.0
5.5 - 15.0
5.5 - 15.0
Min - Max
1.050
1.550
1.720
3.130
kW
3.130
2.060
4.090
4.090
4.840
4.840
Total Input
Rated
3.01
3.01
2.81
2.81
EER
B
B
C
C
EEL Rank
3.6
5.0
5.7
9.4
kW
9.4
7.1
Design Load
214
307
332
kWh/a
645
645
414
SEER
Energy Efficiency Class
A+
A+
A+
A
A
A+
4.1
5.5
6.9
kW
11.2
11.2
7.9
14.0
14.0
16.0
16.0
Rated
Heating Capacity
(Average
1.7 - 5.0
1.7 - 6.6
2.5 - 8.0
kW
4.5 - 12.5
4.5 - 12.5
2.6 - 10.2
5.0 - 16.0
5.0 - 16.0
5.0 - 18.0
5.0 - 18.0
Min - Max
Season) Total Input
1.130
1.520
1.910
kW
3.280
3.280
2.180
4.120
4.120
4.690
4.690
Rated
3.40
3.40
3.41
3.41
COP
C
C
B
B
EEL Rank
2.6
4.0
4.8
kW
8.0
8.0
5.8
Design Load
2.3 (10C)
3.6 (10C)
4.0 (10C)
6.3 (10C)
6.3 (10C)
5.2 (10C)
at bivalent temperature
2.3 (10C)
3.6 (10C)
4.0 (10C)
kW
5.0 (15C)
5.0 (15C)
5.2 (10C)
SCOP
Energy Efficiency Class
A+
A+
A+
A
A
A+
8.5
12.4
A
14.4
Operating Current (max)
13.7
28.7
16.5
28.8
13.8
30.4
13.9
0.04
0.05
kW
0.06
Indoor Input
0.09
0.09
0.06
0.11
0.11
0.14
0.14
Rated
Unit
0.29
0.37
A
0.39
0.65
0.65
0.42
0.76
0.76
0.90
0.90
Operating Current (max)
mm
Dimensions <Panel> H W D
230 - 960 - 680
230 - 1280 - 680
230 - 1600 - 680
24
25
kg
32
36
36
32
38
38
39
39
Weight <Panel>
m3/min 10 - 11 - 12 - 14 10 - 11 - 13 - 15 15 - 16 - 17 - 19 16 - 17 - 18 - 20 22 - 24 - 26 - 28 22 - 24 - 26 - 28 23 - 25 - 27 - 29 23 - 25 - 27 - 29 24 - 26 - 29 - 32 24 - 26 - 29 - 32
Air Volume [Lo-Mi2-Mi1-Hi]
dB(A) 31 - 33 - 36 - 39 32 - 34 - 37 - 40 33 - 35 - 37 - 40 35 - 37 - 39 - 41 37 - 39 - 41 - 43 37 - 39 - 41 - 43 39 - 41 - 43 - 45 39 - 41 - 43 - 45 41 - 43 - 45 - 48 41 - 43 - 45 - 48
Sound Level (SPL) [Lo-Mi2-Mi1-Hi]
60
60
dB(A)
60
63
63
65
62
65
68
68
Sound Level (PWL)
mm 550 - 800 - 285
880 - 840 - 330
Outdoor Dimensions
HWD
943 - 950 - 330 (+30)
1350 - 950 - 330 (+30)
Unit
54
kg
50
77
75
99
53
101
99
101
35
Weight
44.6
m3/min
40.9
60.0
60.0
100.0
50.1
100.0
100.0
100.0
36.3
Air Volume
Cooling
44.6
m3/min
49.2
60.0
60.0
100.0
48.2
100.0
100.0
100.0
34.8
Heating
52
dB(A)
55
50
50
51
55
51
52
52
49
Sound Level (SPL) Cooling
52
dB(A)
55
54
54
55
55
55
56
56
50
Heating
65
dB(A)
65
70
70
71
69
71
73
73
62
Sound Level (PWL) Cooling
12.0
A
14.0
13.0
28.0
28.0
16.1
13.0
29.5
13.0
8.2
Operating Current (max)
A
20
20
16
32
32
20
16
40
16
10
Breaker Size
mm
6.35 / 12.7
Ext.
6.35 / 15.88 9.52 / 15.88 9.52 / 15.88
9.52 / 15.88 9.52 / 15.88 9.52 / 15.88
9.52 / 15.88
9.52 / 15.88
6.35 / 9.52
Diameter
Liquid / Gas
Piping Max. Length
m
30
30
50
50
50
30
50
50
50
20
Out-In
m
30
30
30
30
30
30
30
30
30
12
Max. Height
Out-In
C
15 ~ +46
Guaranteed Operating Range Cooling
15 ~ +46
15 ~ +46*3 15 ~ +46*3 15 ~ +46*3 15 ~ +46*3 15 ~ +46*3 15 ~ +46*3
15 ~ +46
10 ~ +46
[Outdoor]
C
10 ~ +24
10 ~ +24
10 ~ +24
10 ~ +24
15 ~ +21
15 ~ +21
15 ~ +21
15~21
15 ~ +21
15 ~ +21
Heating
*1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance
contains a refrigerant fluid with a GWP equal to 1975. This means that if 1kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1kg of CO2, over a period
of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
*2 Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
*3 Optional air protection guide is required where ambient temperature is lower than 5C. *4 SEER/SCOP values are measured based on EN14825. These values are reference purpose only.
84
PCZ-RP HA SERIES
POWER INVERTER
Optional
Optional
Optional
Optional
Optional
Type
Inverter Heat Pump
Indoor Unit
PCA-RP71HAQ
Outdoor Unit
PUHZ-ZRP71VHA
Refrigerant
R410A*1
Outdoor power supply
Power Source
Supply Outdoor (V/Phase/Hz)
230 / Single / 50
kW
7.1
Rated
Cooling Capacity
kW
3.3 - 8.1
Min - Max
kW
2.17
Total Input
Rated
EER
EEL Rank
kW
7.1
Design Load
kWh/a
447
Annual Electricity Consumption*2
5.6
SEER
Energy Efficiency Class
A+
kW
7.6
Rated
Heating Capacity
(Average
kW
3.5 - 10.2
Min - Max
Season) Total Input
kW
2.35
Rated
COP
EEL Rank
kW
4.7
Design Load
4.7 (10C)
Declared Capacity at reference design temperature kW
kW
4.7 (10C)
at bivalent temperature
kW
3.5 (20C)
at operation limit temperature
kW
0
Back Up Heating Capacity
kWh/a
1751
Annual Electricity Consumption*2
3.8
SCOP
Energy Efficiency Class
A
A
Operating Current (max)
19.4
kW
Indoor Input
0.09
Rated
Unit
A
0.43
Operating Current (max)
mm
280 - 1136 - 650
Dimensions <Panel> H W D
kg
41
Weight <Panel>
m3/min
17 - 19
Air Volume [Lo-Hi]
dB(A)
34 - 38
Sound Level (SPL) [Lo-Hi]
dB(A)
56
Sound Level (PWL)
mm
Outdoor Dimensions
943 - 950 - 330 (+30)
HWD
Unit
kg
67
Weight
m3/min
55.0
Air Volume
Cooling
m3/min
55.0
Heating
dB(A)
47
Sound Level (SPL) Cooling
dB(A)
48
Heating
dB(A)
67
Sound Level (PWL) Cooling
A
19.0
Operating Current (max)
A
25
Breaker Size
mm
Ext.
9.52 / 15.88
Diameter
Liquid / Gas
Piping Max. Length
m
50
Out-In
m
30
Max. Height
Out-In
C
Guaranteed Operating Range Cooling*3
15 ~ +46
[Outdoor]
C
20 ~ +21
Heating
*1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance
contains a refrigerant fluid with a GWP equal to 1975. This means that if 1kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1kg of CO2, over a period
of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
*2 Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
*3 Optional air protection guide is required where ambient temperature is lower than 5C.
85
PSA
SERIES
1,900mm
Back
Left side
Right side
Underneath
600mm
360mm
Main Functions
Multi-language Display
Limited Temperature Range Setting
Auto-off Timer
Operation Lock
Weekly Timer
86
SERIES SELECTION
71-140
100-250
71
71
Heat Caulking
Fixing Method
Joint Lap
Indoor Unit
DC Fan Motor
DC Scroll
Grooved Piping
Vector-Wave
Outdoor Unit
For Single
PUHZ-ZRP71
PUHZ-ZRP100/125/140
PSA-RP71/100/125/140KA
PUHZ-ZRP140/200/250
Remote Controller
Built-in
Indoor Unit
100-140
200/250
DC Rotary
DC Scroll
100-140
Vector-Wave
DC Fan Motor
Grooved Piping
Outdoor Unit
For Single
PUHZ-P100
PUHZ-P125/140
PSA-RP71/100/125/140KA
PUHZ-P200/250
PUHZ-P140
Remote Controller
Built-in
87
For Twin
For Single
35
50
60
71
100
125
140
200
250
71
100
125
140
For Triple
200
250
For Quadruple
140
200
250
200
250
71x3
MSDD-50TR-E MSDD-50WR-E
MSDT-111R-E
71x3
MSDD-50TR-E MSDD-50WR-E
MSDT-111R-E
PSZ-RP SERIES
POWER INVERTER
71-140V
Wi-Fi
Interface
Optional
Optional
Optional
Optional
Optional
Type
Inverter Heat Pump
Indoor Unit
PSA-RP71KA
PSA-RP100KA
PSA-RP125KA
PSA-RP140KA
Outdoor Unit
PUHZ-ZRP71VHA
PUHZ-ZRP100VKA2 PUHZ-ZRP100YKA2 PUHZ-ZRP125VKA2 PUHZ-ZRP125YKA2 PUHZ-ZRP140VKA2 PUHZ-ZRP140YKA2
1
Refrigerant
R410A*
Outdoor power supply
Power Source
Supply Outdoor (V/Phase/Hz)
VKA VHA:230 / Single / 50, YKA:400 / Three / 50
12.5
9.5
9.5
12.5
13.4
13.4
kW
7.1
Rated
Cooling Capacity
5.5 - 14.0
4.9 - 11.4
4.9 - 11.4
5.5 - 14.0
6.2 - 15.0
6.2 - 15.0
kW
3.3 - 8.1
Min - Max
4.09
2.50
2.50
4.09
4.06
4.06
kW
1.89
Total Input
Rated
3.06
3.06
3.30
3.30
EER
EEL Rank
12.5
9.5
9.5
12.5
13.4
13.4
kW
7.1
Design Load
847
606
595
885
872
883
kWh/a
396
Annual Electricity Consumption*2
5.0*4
5.5
5.6
4.9*4
5.3*4
5.3*4
6.3
SEER
Energy Efficiency Class
A
A+
A++
11.2
11.2
kW
7.6
14.0
14.0
16.0
16.0
Rated
Heating Capacity
(Average
4.5 - 14.0
4.5 - 14.0
kW
3.5 - 10.2
5.0 - 16.0
5.0 - 16.0
5.7 - 18.0
5.7 - 18.0
Min - Max
Season) Total Input
3.08
3.08
kW
2.21
4.24
4.24
4.79
4.79
Rated
3.30
3.30
3.34
3.34
COP
EEL Rank
7.8
7.8
kW
4.7
9.3
9.3
10.6
10.6
Design Load
7.8 (10C)
7.8 (10C)
4.7 (10C)
9.3 (10C)
9.3 (10C)
10.6 (10C)
10.6 (10C)
Declared Capacity at reference design temperature kW
7.8 (10C)
7.8 (10C)
kW
4.7 (10C)
9.3 (10C)
9.3 (10C)
10.6 (10C)
10.6 (10C)
at bivalent temperature
5.8 (20C)
5.8 (20C)
kW
3.5 (20C)
7.0 (20C)
7.0 (20C)
7.9 (20C)
7.9 (20C)
at operation limit temperature
0
0
kW
0
0
0
0
0
Back Up Heating Capacity
2761
2761
kWh/a
1666
3285
3285
3331
3331
Annual Electricity Consumption*2
4.0
4.0
4.0
4.0*4
4.0*4
4.4*4
4.4*4
SCOP
Energy Efficiency Class
A+
A+
A+
8.7
A
27.2
Operating Current (max)
19.4
27.2
10.2
28.7
13.7
0.11
kW
0.11
Indoor Input
0.06
0.11
0.11
0.11
0.11
Rated
Unit
0.71
A
0.71
0.4
0.73
0.73
0.73
0.73
Operating Current (max)
mm
1900 - 600 - 360
Dimensions <Panel> H W D
46
kg
46
46
46
46
48
48
Weight <Panel>
25 - 28 - 30
m3/min
25 - 28 - 30
20 - 22 - 24
25 - 28 - 31
25 - 28 - 31
25 - 28 - 31
25 - 28 - 31
Air Volume [Lo-Mid-Hi]
45 - 49 - 51
dB(A)
45 - 49 - 51
40 - 42 - 44
45 - 49 - 51
45 - 49 - 51
45 - 49 - 51
45 - 49 - 51
Sound Level (SPL) [Lo-Mid-Hi]
65
dB(A)
65
60
66
66
66
66
Sound Level (PWL)
mm 943 - 950 - 330 (+30)
Outdoor Dimensions
1338-1050-330(+40)
HWD
Unit
123
kg
116
67
116
125
118
131
Weight
110.0
m3/min
110.0
55.0
120.0
120.0
120.0
120.0
Air Volume
Cooling
110.0
m3/min
110.0
55.0
120.0
120.0
120.0
120.0
Heating
49
dB(A)
49
47
50
50
50
50
Sound Level (SPL) Cooling
51
dB(A)
51
48
52
52
52
52
Heating
69
dB(A)
69
67
70
70
70
70
Sound Level (PWL) Cooling
8.0
A
26.5
19.0
26.5
9.5
28.0
13.0
Operating Current (max)
16
A
32
25
32
16
40
16
Breaker Size
mm
9.52 / 15.88
Ext.
9.52 / 15.88
9.52 / 15.88
9.52 / 15.88
9.52 / 15.88
9.52 / 15.88
9.52 / 15.88
Diameter
Liquid / Gas
Piping Max. Length
m
75
75
50
75
75
75
75
Out-In
m
30
30
30
30
30
30
30
Max. Height
Out-In
C
15 ~ +46
Guaranteed Operating Range Cooling*3
15 ~ +46
15 ~ +46
15 ~ +46
15 ~ +46
15 ~ +46
15 ~ +46
[Outdoor]
C
20 ~ +21
20 ~ +21
20 ~ +21
20 ~ +21
20 ~ +21
20 ~ +21
20 ~ +21
Heating
*1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance
contains a refrigerant fluid with a GWP equal to 1975. This means that if 1kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1kg of CO2, over a period
of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
*2 Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
*3 Optional air protection guide is required where ambient temperature is lower than 5C. *4 SEER/SCOP values are measured based on EN14825. These values are reference purpose only.
PSZ-P SERIES
STANDARD INVERTER
Wi-Fi
Interface
Optional
Optional
Optional
Optional
Optional
Type
Inverter Heat Pump
Indoor Unit
PSA-RP100KA
PSA-RP100KA
PSA-RP125KA
PSA-RP125KA
PSA-RP140KA
PSA-RP140KA
Outdoor Unit
PUHZ-P100VHA4
PUHZ-P100YHA2
PUHZ-P125VHA3
PUHZ-P125YHA
PUHZ-P140VHA3
PUHZ-P140YHA
1
Refrigerant
R410A*
Outdoor power supply
Power Source
Supply Outdoor (V/Phase/Hz)
VHA3 VHA4:230 / Single / 50, YHA YHA2:400 / Three / 50
13.6
13.6
12.3
12.3
9.4
kW
9.4
Rated
Cooling Capacity
5.5 - 15.0
5.5 - 15.0
5.5 - 14.0
5.5 - 14.0
4.9 - 11.2
kW
4.9 - 11.2
Min - Max
5.640
5.640
4.380
4.380
3.120
kW
3.120
Total Input
Rated
2.41
2.41
2.81
2.81
EER
E
E
C
C
EEL Rank
9.4
kW
9.4
Design Load
716
kWh/a
716
Annual Electricity Consumption*2
4.6
4.6
SEER
B
B
16.0
16.0
14.0
14.0
11.2
kW
11.2
Rated
Heating Capacity
(Average
5.0 - 18.0
5.0 - 18.0
5.0 - 16.0
5.0 - 16.0
4.5 - 12.5
kW
4.5 - 12.5
Min - Max
Season) Total Input
5.690
5.690
4.980
4.980
3.280
kW
3.280
Rated
2.81
2.81
2.81
2.81
COP
D
D
D
D
EEL Rank
8.0
kW
8.0
Design Load
6.3 (10C)
6.3 (10C)
Declared Capacity at reference design temperature kW
7.1 (7C)
kW
7.1 (7C)
at bivalent temperature
5.0 (15C)
kW
5.0 (15C)
at operation limit temperature
1.7
kW
1.7
Back Up Heating Capacity
2945
kWh/a
2945
Annual Electricity Consumption*2
3.8
3.8
SCOP
A
A
13.7
30.2
13.7
28.7
A
13.7
Operating Current (max)
28.7
0.11
0.11
0.11
0.11
kW
0.11
Indoor Input
0.11
Rated
Unit
0.73
0.73
0.73
0.73
A
0.71
0.71
Operating Current (max)
mm
1900 - 600 - 360
Dimensions <Panel> H W D
48
48
46
46
kg
46
46
Weight <Panel>
25 - 28 - 31
25 - 28 - 31
25 - 28 - 31
25 - 28 - 31
m3/min
25 - 28 - 30
25 - 28 - 30
Air Volume [Lo-Mid-Hi]
45 - 49 - 51
45 - 49 - 51
45 - 49 - 51
45 - 49 - 51
dB(A)
45 - 49 - 51
45 - 49 - 51
Sound Level (SPL) [Lo-Mid-Hi]
66
66
66
66
dB(A)
65
65
Sound Level (PWL)
mm
Outdoor Dimensions
HWD
943 - 950 - 330 (+30)
1350 - 950 - 330 (+30)
Unit
101
99
101
99
kg
77
75
Weight
100.0
100.0
100.0
100.0
m3/min
60.0
60.0
Air Volume
Cooling
100.0
100.0
100.0
100.0
m3/min
60.0
60.0
Heating
52
52
51
51
dB(A)
50
50
Sound Level (SPL) Cooling
56
56
55
55
dB(A)
54
54
Heating
73
73
71
71
dB(A)
70
70
Sound Level (PWL) Cooling
13.0
29.5
13.0
28.0
A
13.0
28.0
Operating Current (max)
16
40
16
32
A
16
32
Breaker Size
9.52 / 15.88
9.52 / 15.88
9.52 / 15.88
mm
9.52 / 15.88
Ext.
9.52 / 15.88
9.52 / 15.88
Diameter
Liquid / Gas
Piping Max. Length
50
50
50
m
50
50
50
Out-In
30
30
30
m
30
30
30
Max. Height
Out-In
15 ~ +46
15 ~ +46
15 ~ +46
C
15 ~ +46
Guaranteed Operating Range Cooling*3
15 ~ +46
15 ~ +46
[Outdoor]
15 ~ +21
15 ~ +21
15 ~ +21
C
15 ~ +21
15 ~ +21
15 ~ +21
Heating
*1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance
contains a refrigerant fluid with a GWP equal to 1975. This means that if 1kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1kg of CO2, over a period
of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
*2 Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
*3 Optional air protection guide is required where ambient temperature is lower than 5C. *4 SEER/SCOP values are measured based on EN14825. These values are reference purpose only.
88
MULTI
SPLIT
SERIES
89
SELECTION
Choose from seven types of indoor units and twelve outdoor units that can run up to six indoor units each.
Create the system that best matches room shapes and number of rooms.
STEP 1
Wall-mounted
Floor-standing
Cassette
Ceiling-suspended
MSZ-FH
PCA
MSZ-EF
Ceiling-concealed
SLZ-KF
MLZ-KA
SEZ-KD
MSZ-SF (25-50)
PLA
MSZ-GF
PEAD
STEP 2
Select the best outdoor unit based on the number of indoor units and overall system capacity required.
2-port
3-port
up to 2 indoor units
up to 3 indoor units
4-port
HYPER HEATING*
up to 4 indoor units
2-port
up to 2 indoor units
MXZ-2D33VA
MXZ-2D42VA2
MXZ-2D53VA(H)2
5-port
MXZ-3E54VA
MXZ-3E68VA
MXZ-4E72VA
MXZ-4E83VA
MXZ-2E53VAHZ
6-port
up to 5 indoor units
MXZ-5E102VA
up to 6 indoor units
4-port
up to 4 indoor units
MXZ-6D122VA
MXZ-4E83VAHZ
STEP 3
Possible combinations depends on the outdoor unit chosen. Please check the following points.
Refer to the Indoor Unit Compatibility Table to check if the indoor units selected can be used with
the outdoor unit selected. (Indoor units not listed in the table cannot be used.)
Refer to the Combination Table to check if the capacity combination of the indoor unit selected
is connectable. (Combinations not listed cannot be connected.)
If the desired combination cannot be found, please change either the indoor or outdoor unit
to match one of the combinations shown in the tables.
90
MXZ
Outdoor
Unit
SERIES
2-port
MXZ-2D33VA
MXZ-2D42VA2
MXZ-2D53VA (H)2
3-port
4-port
4-port
5-port
6-port
MXZ-4E83VA
MXZ-5E102VA
MXZ-3E54VA
MXZ-3E68VA
MXZ-4E72VA
MXZ-6D122VA
EXAMPLE SYSTEM
MXZ-6D122VA system
MSZ-EF
MSZ-SF
MSZ-FH
MFZ-KJ
MLZ-KA
SLZ-KF
MXZ-6D122VA
Support Functions
Wiring/Piping Correction Function* (3E54/3E68/4E72/4E83/5E102/6D122)
Simply press a single button to confirm if wiring and piping are properly connected. Wiring errors are corrected automatically when discovered. This eliminates the need to confirm complicated wiring
connections when expanding the system. (For details, refer to the
outdoor unit installation manual.)
Wiring
confirmation
is time
consuming.
91
Operation Lock
To accommodate specific use applications, cooling or heating operation can be specified when setting the control board of the outdoor
unit. A convenient option when a system needs to be configured for
exclusive cooling or heating service. (For details, refer to the outdoor
unit installation manual.)
MXZ SERIES
INVERTER MULTI
2D-4E83
4E83-6D
3D-4D72
Up to 2 Indoor Units
N:
Outdoor Unit
MXZ-2D33VA
N:
MXZ-2D42VA2
N:
MXZ-2D53VA2
Up to 3 Indoor Units
Please refer to (*4)
N:
MXZ-2D53VAH2
Refrigerant
Source
Power
Supply Outdoor (V/Phase/Hz)
Cooling
Capacity
N:
MXZ-3E54VA
N:
MXZ-3E68VA
N:
Up to 4 Indoor Units
Up to 5 Indoor Units
MXZ-4E72VA MXZ-4E83VA
MXZ-5E102VA
R410A*1
Outdoor power supply
230 / Single / 50
Rated
Min - Max
kW
kW
4.2
1.1 - 4.4
5.3
5.3
5.4
6.8
7.2
8.3
10.2
1.1 - 3.8
1.1 - 5.6
1.1 - 5.6
2.9 - 6.8
2.9 - 8.4
3.7 - 8.8
3.7 - 9.2
3.9 - 11.0
kW
0.90
1.00
1.54
1.54
1.35
2.19
2.25
2.44
3.15
kW
3.3
5.3
5.3
5.4
6.8
7.2
8.3
10.2
kWh/a
211
4.2
216
262
262
295
425
443
460
537
6.8
A++
7.1
A++
7.1
A++
6.4
A++
5.6
A+
5.7
A+
6.3
A++
A++
4.5
1.0 - 4.8
6.4
6.4
7.0
8.6
8.6
9.3
10.5
1.0 - 4.1
1.0 - 7.0
1.0 - 7.0
2.6 - 9.0
2.6 - 10.6
3.4 - 10.7
3.4 - 11.6
4.1 - 14.0
kW
kW
0.96
0.93
1.70
1.70
1.59
2.38
2.28
2.00
2.34
2.7
3.2
4.5
4.5
5.0
6.8
7.0
8.7
8.9
kW
2.1
2.7
3.7
3.6
4.0
5.4
5.6
7.1
7.3
kW
2.4
3.0
4.0
4.0
4.49
6.0
6.2
7.8
7.9
kW
1.7
2.3
3.3
3.0
3.17
4.4
4.7
6.0
6.3
kW
0.6
0.5
0.8
0.9
1.0
1.4
1.4
1.6
1.6
kWh/a
926
1065
1507
1546
1751
2466
2516
2884
2958
SCOP*
Energy Efficiency Class*4
Max. Operating Current (Indoor+Outdoor)
A
4.1
A+
4.2
A+
4.2
A+
4.1
A+
4.0
A+
3.9
3.9
4.2
A+
4.2
A+
5.5
Energy Efficiency Class*4
Heating Capacity
Rated
(Average
Min - Max
Season)
Input (Indoor+Outdoor) Rated
Design Load
kW
kW
Outdoor Dimensions
Unit
Weight
Air Volume
Sound Level (SPL)
Sound Level (PWL)
HWD
Diameter
4.0
12.2
12.2
550 - 800 (+69) - 285 (+59.5)
10.0
12.2
18.0
37
27.7
38
58
58
59
62
63
32.9
32.9
42.1
42.1
42.1
55.6
65.1
33.7
33.3
33.3
33.3
43.0
43.0
43.0
55.6
68.0
49
46
50
50
50
50
50
49
52
dB(A)
50
51
53
53
53
53
53
51
56
dB(A)
63
60
64
64
64
64
64
61
65
10
15
15
15
25
25
25
25
25
mm
mm
6.35 2
6.35 2
6.35 2
6.35 2
6.35 x 3
6.35 x 3
9.52 2
9.52 2
9.52 2
9.52 2
9.52 x 3
9.52 x 3
20
30
30
30
50
60
60
70
m
m
15
20
20
20
25
25
25
25
25
10
15 (10)*3
20
15 (10)*3
20
15 (10)*3
40
15 (10)*3
40
15 (10)*3
15 (10)*3
15 (10)*3
32
Cooling
m3/min
32.9
Heating
m3/min
Cooling
Heating
dB(A)
Cooling
Liquid
18.0
18.0
710 - 840 (+30) - 330 (+66)
6.6
37
kg
Gas
Total Piping Length (max)
21.4
21.4
796 - 950 - 330
6.35 x 4
6.35 4
6.35 5
12.71+9.523 12.71+9.523 12.71+9.524
80
20
15 (10)*3
20
40
25
Cooling
10 ~ +46
10 ~ +46
10 ~ +46
10 ~ +46
10 ~ +46
10 ~ +46
10 ~ +46
10 ~ +46
10 ~ +46
Heating
15 ~ +24
15 ~ +24
15 ~ +24
20 ~ +24
15 ~ +24
15 ~ +24
15 ~ +24
15 ~ +24
15 ~ +24
Chargeless Length
Guaranteed Operating Range
[Outdoor]
mm
Breaker Size
Ext.
Piping
3.3
m
C
C
Up to 6 Indoor Units
Please refer to (*5)
MXZ-6D122VA
Outdoor Unit
Refrigerant
Source
Power
Supply Outdoor (V/Phase/Hz)
Cooling
Capacity
Input*
R410A*1
Outdoor power supply
230 / Single / 50
Rated
kW
Min - Max
kW
kW
Rated
EER*6
Input*5
Rated
kW
14.0
Min - Max
kW
3.5 - 16.5
Rated
kW
3.31
COP*6
Operating Current (max)*5
Air Volume
Sound Level (SPL)
Sound Level (PWL)
HWD
Diameter
26.8
mm
kg
88
m3/min
63.0
Heating
m3/min
77.0
Cooling
Heating
dB(A)
55
dB(A)
57
Cooling
dB(A)
69
A
mm
32
6.35 6
12.71+9.525
80
m
m
15 (10)*3
Liquid
Gas
Total Piping Length (max)
Each Indoor Unit Piping Length (max)
Max. Height
Chargeless Length
A
A
Cooling
Breaker Size
Ext.
Piping
No. of
MFZ-KJ indoor units
~20m
100g additional (Total 1250g)
1 unit
2 units
Maximum amount
of refrigerant
1250g
Not available (Only one MFZ-KJ series indoor unit can be connected.)
~30m
100g+{(L-20)m20g/m)}
200g+{(L-20)m20g/m)}
Maximum amount
of refrigerant
1600g
1700g
4.23
EEL Rank
Outdoor Dimensions
Unit
Weight
MXZ-2D33VA
3.66
3.33
EEL Rank
Heating Capacity
12.2
3.5 - 13.5
NOTE
When connecting the MFZ-KJ series indoor unit(s) to this outdoor unit, charge additional refrigerant according to
the instructions in the diagram below.
mm
1 unit
2 units
3 units
~50m
100g+{(L-40)m20g/m)}
200g+{(L-40)m20g/m)}
300g+{(L-40)m20g/m)}
Maximum amount
of refrigerant
3000g
3100g
3200g
MXZ-3E68VA MXZ-4E72VA
No. of
MFZ-KJ indoor units
1 unit
2 units
3 units
~60m
100g+{(L-40)m20g/m)}
200g+{(L-40)m20g/m)}
300g+{(L-40)m20g/m)}
Maximum amount
of refrigerant
3200g
3300g
3400g
30
10 ~ +46
Heating
15 ~ +24
No. of
MFZ-KJ indoor units
25
Cooling
MXZ-3E54VA
*1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere.
This appliance contains a refrigerant fluid with a GWP equal to 1975. This means that if 1kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher
than 1kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
*2 Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
*3 If the outdoor unit is installed higher than the indoor unit, max. height is reduced to 10m.
*4 EER/COP, EEL rank, SEER/SCOP values and energy efficiency class are measured
when connected to the indoor units listed below.
MXZ-2D33VA
MSZ-SF15VA + MSZ-EF18VE
MXZ-2D42VA2
MSZ-EF18VE + MSZ-EF25VE
MXZ-2D53VA(H)2
MSZ-EF18VE + MSZ-EF35VE
MXZ-3E54VA
MSZ-EF18VE + MSZ-EF18VE + MSZ-EF18VE
MXZ-3E68VA
MSZ-EF18VE + MSZ-EF25VE + MSZ-EF25VE
MXZ-4E72VA
MSZ-EF18VE + MSZ-EF18VE + MSZ-EF18VE + MSZ-EF18VE
MXZ-4E83VA
MSZ-EF18VE + MSZ-EF18VE + MSZ-EF22VE + MSZ-EF25VE
MXZ-5E102VA
MSZ-EF18VE + MSZ-EF18VE + MSZ-EF22VE + MSZ-EF22VE + MSZ-EF22VE
*5 Power input and operating current (max) figures are for outdoor unit only
*6 EER/COP, EEL rank, values and energy efficiency class are measured
when connected to the indoor units listed below.
MXZ-6D122VA
MSZ-EF22VE 6
92
MXZ-DM
SERIES
2-port
3-port
MXZ-2DM40VA
MXZ-3DM50VA
Three bedrooms
Attention
For MXZ-DM
MSZ-HJ/DM
MXZ-2DM
MXZ-3DM
93
S1 S2 S3 N L
S3 N L
N~ L~
MSZ-HJ/DM
MUZ-HJ/DM
S1 S2 S3 N L
S1 S2 S3
MXZ-DM SERIES
INVERTER MULTI
3HJ
Refrigerant
Source
Power
Supply Outdoor (V/Phase/Hz)
Cooling
Capacity
Input*4
Rated
kW
4.0
Rated
kW
1.05
5.0
1.13
4.42
3.81
EEL Rank*4
Design Load
A
5.0
283
A
kW
4.0
kWh/a
226
6.1
6.1
A++
A++
6.0
1.31
4.58
Rated
kW
4.3
Input
Rated
kW
1.16
COP*
3.71
EEL Rank*4
kW
3.2
kW
2.73
kW
3.01
kW
2.27
kW
0.47
kWh/a
1105
SCOP*
A
HWD
mm
kg
Cooling
m3/min
Heating
m3/min
Cooling
Heating
dB(A)
Cooling
dB(A)
Operating Current
Cooling
Heating
A
A
Breaker Size
Liquid / Gas
Total Piping Length (max)
Each Indoor Unit Piping Length (max)
Max. Height
Chargeless Length
Guaranteed Operating Range
[Outdoor]
dB(A)
Port Diameter
A
4.0
3.34
Design Load
Ext.
Piping
MXZ-3DM50VA
R410A*1
Outdoor power supply
230 / Single / 50
EER*4
Heating
(Average
Season)
Up to 3 Indoor Units
Up to 2 Indoor Units
Outdoor Unit
mm
m
m
m
m
3.73
2.70
0.66
1455
3.8
A
4.0
A+
18.0
710 - 840 (+30) - 330 (+66)
12.2
550 - 800 (+69) - 285 (+59.5)
32
57
37.5
39.6
50
53
64
5.0
5.8
25
6.35 3 / 9.52 3
50
25
15 (10)*3
29.2
31.9
48
52
63
5.1
5.6
15
6.35 2 / 9.52 2
30
20
15 (10)*3
20
40
Cooling
10 ~ +46
Heating
15 ~ +24
C
C
*1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere.
This appliance contains a refrigerant fluid with a GWP equal to 1975. This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher
than 1 kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
*2 Energy consumption based on standard test results.Actual energy consumption will depend on how the appliance is used and where it is located.
*3 If the outdoor unit is installed higher than the indoor unit, max hight is reduced to 10m.
*4 EER/COP, EEL rank, SEER/SCOP values and energy efficiency class are measured when connected to the indoor units listed below.
MXZ-2DM40VA MSZ-DM25VA + MSZ-DM25VA
MXZ-3DM50VA MSZ-DM25VA + MSZ-DM25VA + MSZ-DM25VA
94
PUMY
SERIES
Air conditioning system supports replacement work by simplifying the installation process. Ideal for supporting renewal needs at small offices and stores,
home offices, etc.
PUMY-P112/125/140VKM2(-BS)
PUMY-P112/125/140YKM2(-BS)
EXAMPLE SYSTEM
MSZ-EF
Branch Box
MSZ-FH
MFZ-KJ
PUMY-V(Y)KM2
CITY MULTI
indoor unit
Small Offices
Outdoor unit
Residence
Branch Box
Branch Box
Outdoor unit
Outdoor unit
[P112 140V/YKM2(-BS)]
Refrigerant Piping Lengths
Total length
Maximum allowable length
Farthest indoor from first branch
Maximum meters
Maximum meters
300
150 (175 equivalent)
30
50
40
12
Top-bottom
differential
50m
Indoor unit
95
PUMY SERIES
INVERTER MULTI
Model
Power Source
Cooling Capacity
(nominal)
kW
Power Input
Current Input
kW
A
EER
Indoor Temp.
Outdoor Temp.
kW/kW
W.B.
D.B.
*2
Power Input
Current Input
COP
Indoor Temp.
Outdoor Temp.
Total Capacity
Model / Quantity
kW
kW
A
City Multi
Branch Box
Mixed System
mm
mm
Fan
Type Quantity
Air Flow Rate
m3/min
15.5
3.46
4.52
12.5
Compressor
kW
mm
Weight
kg
4.52
7.23 - 6.87 - 6.62
4.05
3.43
4.48
4.05
3.43
15.0 - 24.0C
15.0 - 24.0C
15.0 - 24.0C
15.0 - 24.0C
15.0 - 24.0C
-5.0 - 46C
-5.0 - 46C
-5.0 - 46C
-5.0 - 46C
-5.0 - 46C
-5.0 - 46C
14.0
16.0
18.0
14.0
16.0
18.0
3.04
3.74
4.47
3.04
3.74
4.47
4.61
4.28
4.03
4.61
4.28
4.03
15.0 - 27.0C
15.0 - 27.0C
15.0 - 27.0C
15.0 - 27.0C
15.0 - 27.0C
15.0 - 27.0C
-20.0 - 15.0C
-20.0 - 15.0C
-20.0 - 15.0C
-20.0 - 15.0C
50 to 130% of outdoor unit capacity
-20.0 - 15.0C
-20.0 - 15.0C
15 - 140/9
15 - 140/10
15 - 140/12
15 - 140/9
15 - 140/10
15 - 140/12
15 - 100/8
15 - 140*3/10
15 - 100/8
15 - 140*3/10*4
15 - 100/8
15 - 140*3/10*4
15 - 100/8
15 - 140*3/10
15 - 100/8
15 - 140*3/10*4
15 - 140*3/10*4
49 / 51
50 / 52
51 / 53
49 / 51
50 / 52
51 / 53
3.5
3.9
15 - 100/8
9.52 Flare
15.88 Flare
Propeller Fan 2
110
1,883
3,884
cfm
kW
Starting Method
Motor Output
External Dimensions (H W D)
3.46
5.53 - 5.26 - 5.07
4.48
L/s
Motor Output
Type Quantity
15.5
14.0
2.79
4.46 - 4.24 - 4.09
15.0 - 24.0C
dB <A>
Liquid Pipe
Gas Pipe
14.0
2.79
kW/kW
D.B.
W.B.
12.5
2.9
0.06 + 0.06
Scroll hermetic compressor 1
Inverter
3.9
2.9
3.5
1,3381,050330 (+25)
122
125
Cooling
Heating
Indoor
Outdoor
27C DB / 19C WB
20C DB
35C
7C DB / 6C WB
Piping Length
7.5m
7.5m
Level Difference
0m
0m
Type
Model Name
Branch Box
PAC-MK51BC
Max. 5
Wiring
Branch
[Indoor Side]
PAC-MK31BC
Liquid
Gas
Main
Liquid
[Outdoor Side]
Gas
Connection Method
to Indoor Unit
to Outdoor Unit
mm
kg
mm
mm
mm
mm
PAC-MK31BCB
Max. 3
0.003
0.05
170 - 450 - 280
kW
A
HWD
PAC-MK51BCB
Max. 3
Max. 5
Outdoor power supply, Branch Box / Outdoor separate power supply
Single phase, 220/230/240V, 50Hz, Single phase, 220V, 60Hz
7.4
6.35 5
9.52 4, 12.7 1
6.7
6.35 3
9.52 3
7.0
6.35 5
9.52 4, 12.7 1
6.5
6.35 3
9.52 3
9.52
15.88
Flared
Brazed
3-wire + Earth wire
3-wire + Earth wire
96
WallMounted
MXZ- *
MXZ- *
MXZ- *
MXZ- *
MXZ- *
MXZ- *
2D33VA 2D42VA2 2D53VA(H)2 2E53VAHZ 2DM40VA 3E54VA
4
MXZ- *
MXZ- *
MXZ- *
3E68VA 3DM50VA 4E72VA
4
MXZ- *
MXZ- *
MXZ- *
MXZ- *
4E83VA 4E83VAHZ 5E102VA 6D122VA
4
MSZ-FH25VE2
MSZ-FH35VE2
MSZ-FH50VE2
MSZ-EF18VE3W/B/S
MSZ-EF22VE3W/B/S
MSZ-EF25VE3W/B/S
MSZ-EF35VE3W/B/S
MSZ-EF42VE3W/B/S
MSZ-EF50VE3W/B/S
MSZ-SF15VA
MSZ-SF20VA
MSZ-SF25VE3
MSZ-SF35VE3
MSZ-SF42VE3
MSZ-SF50VE3
MSZ-GF60VE2
*2
*2
MSZ-GF71VE2
*2
*2
*2
*2
*2
*2
*2
*2
MSZ-DM25VA
MSZ-DM35VA
MSZ-HJ25VA
MSZ-HJ35VA
MSZ-HJ50VA
FloorStanding
MFZ-KJ25VE
MFZ-KJ35VE
MFZ-KJ50VE
1-way
Cassette
* 5* 6
*5
*5
*5
*5
*5
*5
*5
*5
*5
*5
MLZ-KA25VA
MLZ-KA35VA
MLZ-KA50VA
S series
4-way
Cassette
SLZ-KF25VA2
SLZ-KF35VA2
SLZ-KF50VA2
SLZ-KF60VA2
CeilingConcealed
SEZ-KD25VAQ *3
SEZ-KD25VAL*3
SEZ-KD35VAQ
SEZ-KD35VAL
SEZ-KD50VAQ
SEZ-KD50VAL
SEZ-KD60VAQ
SEZ-KD60VAL
SEZ-KD71VAQ
SEZ-KD71VAL
P series
4-way
Cassette
CeilingSuspended
PLA-RP50BA
*7
PLA-RP60BA
*7
PLA-RP71BA
*7
PCA-RP50KAQ
*7
PCA-RP60KAQ
*7
PCA-RP71KAQ
CeilingConcealed
*1
*2
*3
*4
*5
*6
*7
97
*7
PEAD-RP50JAQ
*1
*1
*1
*1
*1*7
*1
*1
PEAD-RP50JALQ
*1
*1
*1
*1
*1*7
*1
*1
PEAD-RP60JAQ
*1
*1*7
*1
*1
PEAD-RP60JALQ
*1
*1*7
*1
*1
PEAD-RP71JAQ
*1
*1*7
*1
*1
PEAD-RP71JALQ
*1
*1*7
*1
*1
Heating
Indoor
Outdoor
Indoor
20C DB
Outdoor
7C
DB, 6C WB
M Series
S Series
P Series (except for PEA)
MXZ Series
POWERFUL HEATING Series
PEA Series
Indoor unit
400V/Three phase/50Hz
Outdoor unit
VE,VA,VHA,VKA:230V/Single phase/50Hz
YA,YHA,YKA:400V/Three phase/50Hz
400V/Three phase/50Hz
M : M Series S : S Series
"S"= Wall-mounted , "F"= Compact floor-standing , "E"= Compact ceiling-concealed ,
"L"= 4- or 1-way cassette , "U"= Outdoor unit
"Z"= Inverter heat pump , "H"= Fixed-speed heat pump , "blank"= Cooling only
Series
Generation
Rated cooling capacity (kW base)
230V / Single phase / 50Hz
"A"= R410A with new A control , "B"= R410A with conventional control ,
"E"= R410A with new A control & ErP correspondance
"HZ"= Hyper Heating model , "H"= Anti -freeze heater equipped model ,
"S"= Silver indoor unit , "W"= White indoor unit , "B"= Black indoor unit
2) P Series
P
U
H
Z
ZRP/RP/P
SHW
71
V
H
A
P Series
"K"= Wall-mounted , "S"= Floor-standing , "L"= 4 -way cassette , "E"= Ceiling-concealed ,
"C"= Ceiling-suspended , "U"= Outdoor unit
"H"= For heating and cooling , "blank"= Cooling only
"Z"= Inverter , "blank"= Fixed-speed
"ZRP"/ "RP"= R410A & cleaning-free pipe reuse , "P"=R410A
"SH"= Powerful heating ZUBADAN , "W"= can be used as air to water application
Rated cooling capacity (kW base)
"V"= 230V / Single phase / 50Hz , "Y"= 400V / Three phase / 50Hz
Generation
"A"= A control
3) MXZ Series
M
X
Z
4
D/E/HJ
72
V
A
HZ
M Series
Multi-system outdoor unit (heat pump)
Inverter heat pump
Maximum number of connectable indoor units
Generation / Type
Rated cooling capacity (kW base)
"V"= 230V / Single phase / 50Hz
"A"= R410A with new A control
"HZ"= Hyper Heating model , "H"= Anti -freeze heater equipped model
98
POWERFUL
HEATING
SERIES
99
SELECTION
Line-up consists of two series.
Choose the series that best matches the building layout.
ZUBADAN SERIES
The line-up includes outdoor unit models 112-140 class and three types of indoor units.
Outdoor Unit
Indoor Unit
4-way cassette
PUHZ-SHW112VHA
PUHZ-SHW112/140YHA
PLA Series
Ceiling-concealed
Wall-mounted
PEAD Series
PKA Series
Outdoor Unit
Indoor Unit
Wall-mounted
MUZ-FH25/35VEHZ
MUFZ-KJ25/35VEHZ
MSZ-FH25 / 35 / 50VE2
Floor-standing
MUZ-FH50VEHZ
MUFZ-KJ50VEHZ
MFZ-KJ25/35/50VE2
MXZ-VAHZ SERIES
Outdoor Unit
MXZ-2E53VAHZ
MXZ-4E83VAHZ
100
ZUBADAN
SERIES
Heating
capacity (kW)
15
ZUBADAN 5HP
P
INV 5H
Power
10
Power
-25oC
-20oC
-20oC
P
INV 4H
ZUBADAN 4-5HP
-25oC
-15oC
-11oC
ZUBADAN 4HP
-7oC
0oC
-25oC
-20oC
-15oC
-10oC
-5oC
0oC
Outdoor-air temperature
Enhanced Comfort
The Flash Injection circuit improves start-up and recover from the defrosting operation. A newly introduced defrost operation control also improves
defrost frequency. These features enable the temperature to reach the set temperature more quickly, and contribute to maintaining it at the
desired setting.
Quick Start-up
Operation at +2C outdoor temperature
ZUBADAN rises quickly,
45C in 10min
15
13kW with 45C indoor
air outlet temperature
19min
10min
Normal INV:
10
Heating
capacity (kW)
Heating
capacity (kW)
Stable
15
13kW with 45C indoor
air outlet temperature
Discharged air
temperature reaches 50oC
45 oC in 19min
10
15
Normal INV:
10
33% faster
5
0
20
45 oC in 30min
10
40 C
30 C
20 C
Room temp.
10 C
0 C
-20 C
18:00
20:00
22:00
0:00
2:00
4:00
6:00
Outdoor temp.
Installation
example
Room temp.
20 C
10 C
-30 C
101
50 C
40 C
30 C
-10 C
60 C
30
60 C
50 C
20
30min
20min
Outdoor temp.
0 C
-10 C
8:00
10:00
12:00
14:00
16:00
18:00
20:00
22:00
SEER
A
SCOP
A+
SCOP
A+
5.5
5.5
Cooling
Heating
5.1
4.0
4.0
PLA-ZRP100BA
PUHZ-SHW112VHA
3.5
PLA-ZRP100BA
PUHZ-SHW112YHA
PLA-ZRP125BA
PUHZ-SHW140YHA
For products with capacity over 12.0kW, SEER/SCOP values are measured based on EN14825. These values are for reference purposes only.
Injection compressor
(injection port)
Indoor
HEX
Power
receiver
Outdoor
HEX
LEV A
LEV B
LEV C
Refrigerant
flow
Heat
interchanger
(HIC)
Injection Compressor
The ZUBADAN Series is equipped with Mitsubishi Electrics original Flash Injection
Circuit, which is comprised of a bypass circuit and heat interchanger (HIC). The
HIC transforms rerouted liquid refrigerant into a gas-liquid state to lower compression load. This process ensures excellent heating performance even when the outdoor temperature drops very low.
In traditional units, when the outdoor temperature is low, the volume of refrigerant
circulating in the compressor decreases due to the drop in refrigerant pressure
and the protection from overheating caused by high compression, thereby reducing heating capacity. The Flash Injection Circuit injects refrigerant to maintain the
refrigerant circulation volume and compressor operation load, thereby maintaining
heating capacity.
LEV B
LEV A
LEV C
B Injection Compressor
Injection
port
Discharge port
Suction port
The compressor is subjected to a heavy load when compressing liquid refrigerant, and the result is lower operation
efficiency. The addition of HIC supports refrigerant heat exchange at two different pressure levels. The heat-exchange
process transforms the injected liquid refrigerant into a gas
liquid state, thereby decreasing the load on the compressor
during the compression process.
Improves heating capacity at low outdoor temperatures, and enables higher indoor-air outlet temperature
adjustment and higher defrost operation speed
102
FH VEHZ
Powerful
Core
for powerful
heating
SERIES
Unlike conventional air conditioning systems, the FH Series doesnt lose heating
capacity when its cold outside. Original technologies ensure excellent heating
performance under extremely low outdoor temperatures and an impressive
guaranteed operating range.
Operation Range
6.0kW
4.0kW
3.2kW
4.5kW
MSZ-EF VEH
-20 oC
3.6kW
3.0kW
MSZ-FH VEHZ
-25 oC
MUZMUZFH25VE FH25VEHZ
MUZMUZFH35VE FH35VEHZ
MSZ-SF
-15 oC
-25oC
MUZMUZFH50VE FH50VEHZ
-20oC
-15oC
-5oC
SNB172F
The Freeze-prevention heater restricts lowered capacity and operation shutdowns caused by the drain water freezing. This supports
stable operation in low-temperature environments.
SEER
9.1
Cooling
SEER
8.9
SCOP
4.9
Heating
SEER
7.2
SCOP
4.8
SCOP
4.2
Operation Guaranteed at
Outside Temperature of 25C
Frozen
drain
Drain does
not freeze
MUZ-FH25VEHZ
103
0 oC
Downsized
by 13%
TNB175F
-10oC
MUZ-FH35VEHZ
MUZ-FH50VEHZ
Sensor with
eight elements
Indirect Airflow
Direct Airflow
Absence Detection
The sensors detect whether there are people in the room. When no-one is in the room,
the unit automatically switches to energy-saving mode.
8 94 areas
Sensor measures while
moving to the left to right
Divided into 94
(Image)
The 3D i-see Sensor detects peoples absence and the power consumption is automatically
reduced approximately 10% after 10 minutes and 20% after 60 minutes.
Air, like water, is something we use everyday unconsciously. Yet, clean, fresh air is a vital part of creating a healthy space for humans. Achieving
this healthy air is Plasma Quad, a plasma-based filter system that effectively removes four kinds of air pollutants; namely, bacteria, viruses,
allergens and dust, which the air contains countless particles of.
Viruses
Bacteria
Test results have confirmed that Plasma Quad
neutralizes 99% of bacteria in 115 minutes in a
25m3 test space.
Plasma Quad on
Dust
In a test, air containing dust and ticks was
passed through the air cleaning device at the
low airflow setting. Before and after measurements confirm that Plasma Quad removes
88.6% of dust and ticks.
Allergens
In a test, air containing cat fur and pollen was
passed through the air cleaning device at the
low airflow setting. Before and after measurements confirm that Plasma Quad neutralizes
94% of cat fur and 98% of pollen.
(Image)
[ Effective Range ]
Macro
Dust
Particulate size
Allergens
Virus
Nano
Bad Odours
Plasma Quad attacks bacteria and viruses from inside the unit using a strong curtain-like
electrical field and discharge of electric current across the whole inlet-air opening of the
unit. Tungsten discharge electrodes are used as they provide both discharge capacity and
strength. In addition, through flattening the standard, round form of the field to a ribbon-like
shape, a strong electrical field is produced.
Pollen
Bacteria
Mold spores
Round:
Air
Virus
Dust
Pet odours
Fish odours
Virus
Bacteria
Rubbish odours
Plasma
space
Plasma Quad
Air-purifying filter
Neutralization/inactivation
Air
104
MXZ-VAHZ
SERIES
(MXZ-2D53VA2)
6.4kW
6.4kW
Our conventional
model was not able
to maintain standard
rated heating
capacity, making it
hard to provide
warming in case of
low outside-air
temperatures.
(MXZ-2E53VAHZ)
Falls
Maintained
3.0kW
With outside
temperature of 15C
With outside
temperature of 7C
With outside
temperature of 15C
Conventional model
Heating operation*1
*1: Conventional model performs continuous heating approximately 30min up to a maximum of 90min.
105
Heating
operation
*1
Defrosting
operation
During
defrosting
operation,
the heater
stops and
is cold
Defrosting
operation
MXZ-VAHZ SERIES
Defrosting
operation
Heating
operation
*1
Clean/
Neat installation
EXAMPLE SYSTEM
MXZ-4E83VAHZ system
MSZ-EF
MSZ-FH
MFZ-KJ
SLZ-KF
MXZ-4E83VAHZ
OUTDOOR UNITS
2-room use
4-room use
MXZ-2E53VAHZ
MXZ-4E83VAHZ
INDOOR UNITS
Wall-mounted
Cassette
Floor-standing
Ceiling-suspended
1
MSZ-FH
PCA
Ceiling-concealed
SLZ-KF
MSZ-EF
MLZ-KA
1
MFZ-KJ
MSZ-SF
SEZ-KD
PLA
MSZ-GF
PEAD
1: P series cannot be connect with MXZ-4E83VAHZ when ampere limit adjustment function is operated.
106
PLZ-SHW SERIES
Indoor Unit
Remote Controller
Outdoor Unit
PUHZ-SHW112VHA(-BS)
PUHZ-SHW112/140YHA(-BS)
Enclosed in
PLP-6BALM/PLP-6BALME
PLA-ZRP100/125BA
Standard Panel
*optional
Optional
Optional
*optional
Optional
100/125
Wi-Fi
Interface
Optional
Optional
Optional
Optional
Optional
Type
Indoor Unit
Outdoor Unit
PUHZ-SHW112VHA(-BS)
Refrigerant
Source
Power
Supply Outdoor (V/Phase/Hz)
Cooling
Capacity
Total Input
EER
Min - Max
kW
Rated
kW
EEL Rank
kW
kWh/a
SEER
Energy Efficiency Class
Heating Capacity
(Average
Season)
Total Input
kW
kW
4.5 - 14.0
2.667
4.5 - 14.0
2.667
kW
12.7
11.2
12.7
11.2
11.2
9.4
1.5
11.2
9.4
1.5
4420
4.0
A+
4420
4.0
A+
3.5*4
35.7
0.08
0.74
13.7
0.08
0.74
298 - 840 - 840 <35 - 950 - 950>
0.09
0.80
26 <6>
20 - 23 - 26 - 30
26 <6>
20 - 23 - 26 - 30
32 - 34 - 37 - 40
65
32 - 34 - 37 - 40
65
1350 - 950 - 330 (+30)
134
100.0
100.0
kW
at bivalent temperature
kW
kW
kW
kWh/a
SCOP
Energy Efficiency Class
Operating Current (max)
Input
Rated
Operating Current (max)
kW
Dimensions <Panel> H W D
Weight <Panel>
mm
dB(A)
dB(A)
HWD
mm
kg
m /min
Heating
m /min
120
100.0
100.0
Cooling
dB(A)
51
51
Heating
dB(A)
Cooling
Operating Current (max)
dB(A)
52
69
52
69
35.0
13.0
A
mm
40
9.52 / 15.88
16
9.52 / 15.88
75
75
m
C
30
15 ~ +46
25 ~ +21
30
15 ~ +46
25 ~ +21
Cooling
Breaker Size
Diameter
Liquid / Gas
Max. Length
Out-In
Max. Height
Guaranteed Operating Range
[Outdoor]
107
kg
m3/min
Ext.
Piping
14.0
5.0 - 16.0
Rated
Air Volume
12.5
5.5 - 14.0
4.449
2.81
12.5
856
5.1*4
Min - Max
EEL Rank
Outdoor Dimensions
Unit
Weight
10.0
4.9 - 11.4
2.786
10.0
633
5.5
A
11.2
kW
Design Load
Indoor
Unit
10.0
4.9 - 11.4
2.786
10.0
633
5.5
A
11.2
Rated
COP
Declared Capacity
PUHZ-SHW140YHA(-BS)
R410A*1
Outdoor power supply
Rated
Design Load
PLA-ZRP125BA
PUHZ-SHW112YHA(-BS)
Out-In
Cooling*3
Heating
3
3
o
o
3.879
3.61
15.8
14.0
14.0
9.5
1.8
6213
13.8
27 <6>
22 - 25 - 28 - 31
34 - 36 - 39 - 41
66
134
100.0
100.0
51
52
69
13.0
16
9.52 / 15.88
75
30
15 ~ +46
25 ~ +21
*1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere.
This appliance contains a refrigerant fluid with a GWP equal to 1975. This means that if 1kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher
than 1kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
*2 Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
*3 Optional air protection guide is required where ambient temperature is lower than 5C.
*4 SEER/SCOP values are measured based on EN14825. These values are reference purpose only.
PLZ-SHW SERIES
Indoor Unit
Remote Controller
Outdoor Unit
PUHZ-SHW112VHA(-BS)
PUHZ-SHW112/140YHA(-BS)
Enclosed in
PLP-6BALM/PLP-6BALME
PLA-RP100/125BA
Standard Panel
*optional
Optional
Optional
*optional
Optional
100/125
Wi-Fi
Interface
Optional
Optional
Optional
Optional
Optional
Type
Indoor Unit
Outdoor Unit
PUHZ-SHW112VHA(-BS)
Refrigerant
Source
Power
Supply Outdoor (V/Phase/Hz)
Cooling
Capacity
Total Input
EER
Min - Max
kW
Rated
kW
EEL Rank
kW
kWh/a
SEER
Energy Efficiency Class
Heating Capacity
(Average
Season)
Total Input
Rated
kW
Min - Max
kW
Rated
kW
COP
Declared Capacity
kW
at reference design temperature
kW
at bivalent temperature
kW
10.0
4.9 - 11.4
2.850
10.0
661
5.3
A
11.2
10.0
4.9 - 11.4
2.850
10.0
661
5.3
A
11.2
4.5 - 14.0
2.794
4.5 - 14.0
2.794
EEL Rank
Design Load
kW
kW
kWh/a
SCOP
Energy Efficiency Class
12.7
11.2
11.2
9.4
12.7
11.2
11.2
9.4
1.5
4445
4.0
A+
1.5
4445
4.0
A+
35.7
13.7
Input
Rated
Operating Current (max)
kW
0.14
0.94
Dimensions <Panel> H W D
Weight <Panel>
mm
0.14
0.94
298 - 840 - 840 <35 - 950 - 950>
25 <6>
20 - 23 - 26 - 30
32 - 34 - 37 - 40
Indoor
Unit
kg
m3/min
dB(A)
25 <6>
20 - 23 - 26 - 30
32 - 34 - 37 - 40
dB(A)
62
62
Air Volume
HWD
Cooling
mm
kg
m3/min
3
Heating
m /min
Cooling
dB(A)
Heating
dB(A)
Cooling
Operating Current (max)
dB(A)
Outdoor Dimensions
Unit
Weight
Liquid / Gas
Max. Length
Out-In
Max. Height
Guaranteed Operating Range
[Outdoor]
A
A
Diameter
Out-In
Cooling*3
Heating
PUHZ-SHW140YHA(-BS)
R410A*1
Outdoor power supply
Rated
Design Load
PLA-RP125BA
PUHZ-SHW112YHA(-BS)
mm
m
m
C
o
o
120
100.0
100.0
51
100.0
100.0
51
52
69
35.0
52
69
13.0
40
9.52 / 15.88
75
16
9.52 / 15.88
75
30
15 ~ +46
25 ~ +21
30
15 ~ +46
25 ~ +21
12.5
5.5 - 14.0
4.449
2.81
12.5
858
5.1*4
14.0
5.0 - 16.0
3.879
3.61
15.8
14.0
14.0
9.5
1.8
6506
3.4*4
13.8
0.15
1.00
25 <6>
22 - 25 - 28 - 31
34 - 36 - 39 - 41
63
134
100.0
100.0
51
52
69
13.0
16
9.52 / 15.88
75
30
15 ~ +46
25 ~ +21
*1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere.
This appliance contains a refrigerant fluid with a GWP equal to 1975. This means that if 1kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher
than 1kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
*2 Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
*3 Optional air protection guide is required where ambient temperature is lower than 5C.
*4 SEER/SCOP values are measured based on EN14825. These values are reference purpose only.
108
PKZ-SHW SERIES
Remote Controller
Outdoor Unit
Indoor Unit
PKA-RP100KAL
PUHZ-SHW112VHA(-BS)
PUHZ-SHW112/140YHA(-BS)
*optional
*optional
Wi-Fi
Interface
Optional
Optional
Optional
Optional
PUHZ-SHW112VHA(-BS)
Refrigerant
Source
Power
Supply Outdoor (V/Phase/Hz)
Total Input
Design Load
PUHZ-SHW112YHA(-BS)
Rated
kW
10.0
10.0
Min - Max
kW
4.9 - 11.4
4.9 - 11.4
kW
kW
2.924
2.924
10.0
10.0
kWh/a
673
673
5.2
5.2
Rated
Declared Capacity
Rated
kW
11.2
11.2
Min - Max
kW
4.5 - 14.0
4.5 - 14.0
Rated
kW
kW
3.103
3.103
12.7
12.7
kW
11.2
11.2
at bivalent temperature
kW
11.2
11.2
kW
9.4
kW
kWh/a
1.5
1.5
4664
4664
3.8
3.8
9.4
35.6
13.6
Input
Rated
Operating Current (max)
kW
A
0.08
0.08
Dimensions <Panel> H W D
Weight <Panel>
mm
Indoor
Unit
0.57
365 - 1170 - 295
kg
21
21
m3/min
20 - 23 - 26
20 - 23 - 26
dB(A)
41 - 45 - 49
41 - 45 - 49
dB(A)
65
Air Volume
HWD
Cooling
mm
65
1350 - 950 - 330 (+30)
kg
120
134
m3/min
100.0
100.0
Heating
m /min
100.0
100.0
Cooling
Heating
dB(A)
51
51
dB(A)
52
52
Cooling
Operating Current (max)
dB(A)
69
69
35.0
13.0
0.57
Outdoor Dimensions
Unit
Weight
Diameter
Liquid / Gas
Max. Length
Out-In
Max. Height
Guaranteed Operating Range
[Outdoor]
Optional
R410A*1
Outdoor power supply
Heating Capacity
(Average
Season)
Total Input
Design Load
Optional
Outdoor Unit
Capacity
Optional
Optional
Type
Indoor Unit
Cooling
Optional
Out-In
Cooling*3
Heating
40
16
mm
9.52 / 15.88
9.52 / 15.88
75
m
C
30
30
15 ~ +46
15 ~ +46
25 ~ +21
25 ~ +21
75
*1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere.
This appliance contains a refrigerant fluid with a GWP equal to 1975. This means that if 1kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher
than 1kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
*2 Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
*3 Optional air protection guide is required where ambient temperature is lower than 5C.
109
PEDZ-SHW JA SERIES
Indoor Unit
Remote Controller
Outdoor Unit
PUHZ-SHW112VHA(-BS)
PUHZ-SHW112/140YHA(-BS)
PEAD-RP100/125JA(L)Q
*optional
*optional
*optional
100/125
Wi-Fi
Interface
Optional
Optional
Optional
Optional
Optional
JAQ
Optional
Type
Indoor Unit
Outdoor Unit
PUHZ-SHW112VHA(-BS)
Refrigerant
Source
Power
Supply Outdoor (V/Phase/Hz)
Cooling
Capacity
Total Input
EER
Rated
kW
Min - Max
kW
Rated
kW
EEL Rank
kW
kWh/a
10.0
4.9 - 11.4
2.924 (2.904)
10.0
729 (714)
4.8 (4.9)
B
11.2
4.5 - 14.0
12.5
5.5 - 14.0
3.895 (3.875)
3.21 (3.22)
12.5
906 (892)
4.8 (4.9)*4
14.0
5.0 - 16.0
3.879
3.61
kW
Min - Max
kW
Rated
kW
3.103
3.103
kW
12.7
11.2
11.2
12.7
11.2
11.2
kW
kWh/a
9.4
1.5
4664
9.4
1.5
4664
3.8
A
37.7
3.8
A
15.7
kW
A
Dimensions
mm
41 (40)
24.0 - 29.0 - 34.0
35 / 50 / 70 / 100 / 150
41 (40)
24.0 - 29.0 - 34.0
35 / 50 / 70 / 100 / 150
43 (42)
29.5 - 35.5 - 42.0
35 / 50 / 70 / 100 / 150
29 - 34 - 38
61
29 - 34 - 38
61
33 - 36 - 40
65
120
100.0
100.0
134
100.0
100.0
51
52
69
51
52
69
mm
35.0
40
9.52 / 15.88
13.0
16
9.52 / 15.88
75
75
m
C
30
15 ~ +46
30
15 ~ +46
25 ~ +21
25 ~ +21
EEL Rank
Design Load
Declared Capacity
kW
at bivalent temperature
kW
kW
SCOP
Energy Efficiency Class
Operating Current (max)
HWD
Weight
kg
m3/min
dB(A)
dB(A)
Outdoor Dimensions
Unit
Weight
Air Volume
Pa
HWD
mm
kg
Cooling
m /min
3
Heating
m /min
Cooling
Heating
dB(A)
Cooling
dB(A)
Diameter
Liquid / Gas
Max. Length
Out-In
Max. Height
Guaranteed Operating Range
[Outdoor]
dB(A)
A
Breaker Size
Ext.
Piping
10.0
4.9 - 11.4
2.924 (2.904)
10.0
729 (714)
4.8 (4.9)
B
11.2
4.5 - 14.0
Rated
COP
Indoor
Unit
PUHZ-SHW140YHA(-BS)
R410A*1
Outdoor power supply
Design Load
Heating Capacity
(Average
Season)
Total Input
PEAD-RP125JA(L)Q
PUHZ-SHW112YHA(-BS)
Out-In
Cooling*3
Heating
15.8
14.0
14.0
9.5
1.8
6072
3.6*4
15.8
51
52
69
13.0
16
9.52 / 15.88
75
30
15 ~ +46
25 ~ +21
*1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere.
This appliance contains a refrigerant fluid with a GWP equal to 1975. This means that if 1kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher
than 1kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
*2 Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
*3 Optional air protection guide is required where ambient temperature is lower than 5C.
*4 SEER/SCOP values are measured based on EN14825. These values are reference purpose only.
110
25-35
25-35
SEER SCOP
A+++ A++
Indoor Unit
Remote Controller
Outdoor Unit
MUZ-FH25/35VEHZ
MSZ-FH25/35/50VE
Electrostatic
Anti-allergy
HUMAN
MUZ-FH50VEHZ
Weekly
Timer
Natural Flow
Optional
Wi-Fi
Interface
Optional
Optional
Optional
Optional
Type
Indoor Unit
Outdoor Unit
MSZ-FH25VE
MSZ-FH50VE
MUZ-FH25VEHZ
MUZ-FH35VEHZ
MUZ-FH50VEHZ
Refrigerant
Source
Power
Supply Outdoor (V/Phase/Hz)
Cooling
R410A (*1)
Outdoor power supply
230 / Single / 50
Design Load
Annual Electricity Consumption (*2)
kW
kWh/a
SEER (*4)
Energy Efficiency Class
Capacity
Total Input
Heating Design Load
(Average Declared Capacity
Season)(*5)
8.9
7.2
A+++
A++
2.5
3.5
5.0
0.8 - 3.5
0.8 - 4.0
1.9 - 6.0
Rated
kW
kW
0.485
0.820
1.380
3.2
4.0
6.0
kW
3.2
4.0
6.0
at bivalent temperature
kW
3.2
4.0
6.0
kW
1.7
2.6
3.8
kW
kWh/a
0.0
0.0
0.0
924
1173
2006
4.9
4.8
A++
A++
4.2
A+
SCOP *
kW
3.2
4.0
6.0
Min - Max
kW
1.0 - 6.3
1.0 - 6.6
1.7 - 8.7
Rated
kW
0.580
0.800
1.480
Input
9.6
10.5
14.0
Rated
kW
0.029
0.029
0.031
0.4
0.4
0.4
HWD
mm
Outdoor Dimensions
Unit
Weight
Air Volume
Sound Level (SPL)
Sound Level (PWL)
HWD
Cooling
kg
m3/min
13.5
13.5
m /min
dB(A)
20 - 23 - 29 - 36 - 42
21 - 24 - 29 - 36 - 42
27 - 31 - 35 - 39 - 44
dB(A)
20 - 24 - 29 - 36 - 44
21 - 24 - 29 - 36 - 44
25 - 29 - 34 - 39 - 46
dB(A)
58
58
mm
60
880 - 840 - 330
kg
37
37
55
m3/min
31.3
33.6
48.8
Heating
m /min
31.3
33.6
51.3
Cooling
Heating
dB(A)
46
49
51
dB(A)
49
50
54
Cooling
dB(A)
60
61
64
9.2
10.1
13.6
Liquid / Gas
Max. Length
Out-In
Max. Height
Out-In
9.1
A+++
kW
( 4)
Ext.
Piping
244
kW
Indoor
Unit
5.0
138
Min - Max
( 2)
Total Input
Operating Current (max)
3.5
96
Rated
Capacity
2.5
10
12
16
mm
6.35 / 9.52
6.35 / 9.52
6.35 / 12.7
30
20
20
m
C
12
12
15
Cooling
10 ~ +46
10 ~ +46
10 ~ +46
Heating
25 ~ +24
25 ~ +24
25 ~ +24
(*1) Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere.
This appliance contains a refrigerant fluid with a GWP equal to 1975. This means that if 1kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher
than 1kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
(*2) Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
(*3) SHi: Super High
(*4) SEER, SCOP and other related description are based on COMMISSION DELEGATED REGULATION (EU) No.626/2011. The temperature conditions for calculating SCOP are based on Average Season.
(*5) Please see page 47 for heating (warmer season) specifications.
111
25
MFZ-KJ SERIES
SEER SCOP
A+++ A+
Indoor Unit
Outdoor Unit
Remote Controller
MUFZ-KJ25/35VEHZ
MFZ-KJ25/35/50VE
MUFZ-KJ50VEHZ
Nano
Platinum
Wi-Fi
Interface
Optional
Type
Indoor Unit
Outdoor Unit
MFZ-KJ50VE
MUFZ-KJ25VEHZ
MUFZ-KJ35VEHZ
MUFZ-KJ50VEHZ
kW
kWh/a
2.5
3.5
5.0
102
150
266
8.5
8.1
6.5
kW
A+++
2.5
A++
3.5
A++
5.0
Min - Max
kW
0.5 - 3.4
0.5 - 3.7
1.6 - 5.7
Rated
kW
kW
0.540
0.940
1.410
3.5
3.6
4.5
kW
3.5
3.6
4.5
at bivalent temperature
kW
3.5
3.6
4.5
kW
1.6
2.3
3.3
kW
kWh/a
0.0
0.0
0.0
1104
1158
1467
4.4
A+
4.3
A+
4.2
A+
Total Input
Heating Design Load
(Average Declared Capacity
Season)
( 2)
SCOP *
( 4)
Rated
kW
3.4
4.3
6.0
Min - Max
kW
Rated
kW
A
1.2 - 5.1
0.770
1.2 - 5.8
1.100
2.2 - 8.4
1.610
Input
Rated
kW
A
HWD
mm
4.42
3.91
3.73
0.016
0.016
0.038
0.17
0.34
0.17
kg
15
15
15
Air Volume
Cooling
(SLo-Lo-Mid-Hi-SHi (*3) (Dry/Wet)) Heating
Sound Level (SPL)
Cooling
(SLo-Lo-Mid-Hi-SHi (*3))
Heating
m3/min
m /min
dB(A)
20 - 25 - 30 - 35 - 39
20 - 25 - 30 - 35 - 39
27 - 31 - 35 - 39 - 44
dB(A)
19 - 25 - 30 - 35 - 41
19 - 25 - 30 - 35 - 41
29 - 35 - 40 - 45 - 50
dB(A)
49
50
Outdoor Dimensions
Unit
Weight
Air Volume
Sound Level (SPL)
Sound Level (PWL)
HWD
Cooling
mm
56
880 - 840 - 330
kg
37
37
55
m3/min
31.3
31.3
45.8
m /min
33.6
33.6
45.8
Cooling
Heating
dB(A)
46
47
49
dB(A)
51
51
51
Cooling
dB(A)
59
60
63
9.2
10
13.6
Breaker Size
Diameter
Liquid / Gas
Max. Length
Out-In
Max. Height
Out-In
Heating
Optional
R410A (*1)
Outdoor power supply
230 / Single / 50
Design Load
Capacity
Optional
MFZ-KJ25VE
Refrigerant
Source
Power
Supply Outdoor (V/Phase/Hz)
Cooling
Optional
10
12
16
mm
6.35 / 9.52
6.35 / 9.52
6.35 / 12.7
20
m
C
12
12
15
Cooling
10 ~ +46
10 ~ +46
10 ~ +46
Heating
25 ~ +24
25 ~ +24
25 ~ +24
20
30
(*1) Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere.
This appliance contains a refrigerant fluid with a GWP equal to 1975. This means that if 1kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher
than 1kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
(*2) Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
(*3) SHi: Super High
(*4) SEER, SCOP and other related description are based on COMMISSION DELEGATED REGULATION (EU) No.626/2011. The temperature conditions for calculating SCOP are based on Average Season.
112
4E
MXZ-VAHZ SERIES
Outdoor Unit
MXZ-2E53VAHZ
MXZ-4E83VAHZ
Type
Indoor Unit
Outdoor Unit
MXZ-2E53VAHZ
Refrigerant
Source
Power
Supply Outdoor (V/Phase/Hz)
Cooling
Capacity
Total Input
Design Load
230 / Single / 50
Rated
kW
5.3
8.3
Min - Max
kW
1.1 - 6.0
3.5 - 9.2
kW
kW
1.29
2.25
5.3
8.3
kWh/a
282
447
Rated
SEER*
6.5
6.5
A++
A++
kW
6.4
9.0
kW
6.4
9.0
Rated (15C)
kW
6.4
9.0
Min - Max
kW
1.0 - 7.0
3.5 - 11.6
Total Input
Design Load
Rated
kW
1.36
1.90
kW
6.4
10.1
Declared Capacity
kW
6.4
9.0
at bivalent temperature
kW
6.4
9.0
kW
2.4
2.5
kW
kWh/a
0.0
1.1
2165
3446
4.1
A+
4.1
A+
Heating Capacity
(Average
Season)
HWD
Cooling
15.6
28.0
mm
kg
61
87
m3/min
47.0
63.0
Heating
m /min
47.0
77.0
Cooling
Heating
dB(A)
45
53
dB(A)
47
57
Cooling
dB(A)
55
66
16
30
mm
6.35 2 / 9.52 2
Breaker Size
Ext.
Piping
MXZ-4E83VAHZ
R410A*1
Outdoor power supply
Diameter
Liquid / Gas
Total Piping Length (max)
30
20
Max. Height
Chargeless Length
Guaranteed Operating Range
[Outdoor]
m
C
Cooling
Heating
25
3
15 (10) *
20
10 ~ +46
15 (10) *3
25
10 ~ +46
25 ~ +24
25 ~ +24
*1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere.
This appliance contains a refrigerant fluid with a GWP equal to 1975. This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher
than 1 kg of CO2 , over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
*2 Energy consumption based on standard test results.
Actual energy consumption will depend on how the appliance is used and where it is located.
*3 If the outdoor unit is installed higher than the indoor unit, max. height is reduced to 10m.
*4 EER/COP, EEL rank, SEER/SCOP values and energy efficiency class are measured
when connected to the indoor units listed below.
MXZ-2E53VAHZ MSZ-EF18VE + MSZ-EF35VE
MXZ-4E83VAHZ MSZ-EF18VE + MSZ-EF18VE + MSZ-EF22VE + MSZ-EF25VE
*5 Indoor unit compatibility table is shown on page 93.
113
Installation Location
Correct
installation
Wrong
installation
Drainage water
splashes on
pedestrians.
Wrong
installation
Unit may freeze and
become damaged because
water will not be drained
from the drain hole.
Point!
Install at a sufficient height from the ground
to prevent problems caused by frozen
drainage water.
Install in a location where frozen drainage
water will not be a hazard.
Install in an upright position to allow proper
drainage from the drainage outlet.
Correct
installation
Note!
Place units
side by side.
Wrong
installation
Bottom unit
may freeze.
114
Correct
installation
Point!
Install at a position/height to prevent the unit being
buried in snow *1 and the adverse effects of frozen
drainage water.*2
Install so as to avoid the effects of snow or snowdrift.
Install so as to avoid the damage from falling snow or icicles.
*1 Install at a height above the highest snowfall depth.
may
form an icicle which needs to be cleared away regularly to
prevent a blocked drainage outlet.
Wrong
installation
Wrong
installation
Correct
installation
Minimum height (h)
should be higher
than the highest
snowfall depth (h0)
Wrong
installation
Air exhaust
snow hood
Air intake
snow hood
(rear)
Air intake
snow hood
(side panel)
+20cm
Correct
installation
h0
Point!
Without hood
Snowfall
height h0
Stand height h
Necessity of accessories (drain socket & centralised drain pan, stand, snow protection hood, base heater)
Drain socket,
Centralised drain pan
Stand
Snowy region
Cold region
Countermeasures
for snow
Countermeasures
for freezing
Not used
Not used
Prevents freezing
Needed
Needed
Remarks
Clearance to prevent
snow accumulating.
<Correct>
Needed
Snow
protection
hood
Base heater
CAUTION
Needed
In the case that fitting a drain socket is absolutely necessary, steps must be taken so that the drainage water does not freeze.
For more information, please consult Mitsubishi Electric or one of its dealers/resellers.
Arrangement for
snow protection hood
115
116
Description
Part Name
Deodourising Filter
Description
Quick-clean Kit
Quick-clean kit
Drain Pump
Air-cleaning Filter
Drain pump
*for ceiling-suspended units
Decorative Cover
Decorative cover
Air-cleaning filter
Decorative
cover
Captures the bacteria, pollen and other allergens in the air and neutralises them.
Filter frame
Indoor unit
MA & contact
terminal interface
System control
interface
Wi-Fi Interface
WiFi interface
Filter element
Plug
(for directing
airflow)
High-efficiency
filter element
Interface enabling users to control air conditioners and check operating status via
devices such as personal computers, tablets
and smartphones.
Smartphone
i-see Sensor
corner panel
i-see Sensor
corner panel
Shuttle Plate
Shuttle Plate
Multi-functional Casement
Multi-functional
casement
Advanced deluxe remote controller with fulldot liquid-crystal display and backlight.
Equipped with convenient functions like nightsetback.
Relay
Space Panel
Switch
Space Panel
Panel
117
Connector Cable
Handheld unit
Part Name
Description
Part Name
Description
Signal receiver
Signal receiver
Signal sender
Drain Socket
Cap
Socket
Control Holder
Outdoor unit
Centralised drain pan
Base
(local construction)
Remote Sensor
M-NET Converter
M-NET
Converter
Remote sensor
Control/Service Tool
Control/service tool
Step Interface
Interface for adjusting the capacity of inverterequipped outdoor units. (For further details,
refer to pg. 130.)
Case interior
Installed in case
Distribution Pipe
Indoor unit
Branch pipe for P Series simultaneous multisystem use, or to connect two branch boxes
for MXZ-8B140V(Y)A/160V(Y)A systems.
Indoor unit
MELCloud
Outdoor unit
Distribution pipe
*P Series with 2 indoor units
Joint Pipe
Joint pipe
Onsite pipe
Indoor unit
Insulator
Outdoor unit
Additional functions
Remote control
User types
MELCloud has been designed for wide range of users from single users
with single air conditioning or heating systems in a single building, up to
larger user who may have multiple properties and multiple systems that they
wish to monitor and control.
Whichever type of user you are, MELCloud can provide you with required
control and access you need for modern living.
Remote operation can be achieved as long as you have a connected system and you
have an internet connection at the location of your equipment.
Local operation is also possible if you close to where the system that you wish to
control is, but simply to not wish to use the local controller and have your PC, Tablet
or Smartphone to hand. Please note this is not direct connection via router, local
cotnrol still requires internet connection to work.
118
Option
MAC2360
FT
Indoor Unit
M SERIES
Wall mounted
Floor standing
1-way
cassette
S SERIES
4-way
cassette
Ceiling conceald
4-way
Cassette
P SERIES
Ceiling conceald
Wall mounted
Ceiling suspended
Floor standing
Silver-ionized
Air Purifier Filter
MAC- MAC- MAC2370 2380 172
FT-E
FT
FT
MAC3005
CF-E
High-efficiency
Filter Element
Filter Box
i-see 3D i-see
MultiSoftdry Sensor Sensor Shutter
functional
cloth Corner Corner Plate
Casement
Panel Panel
PAC- PAC- PAC- PAC- PAC- PAC- PAC- PAC- PAC- MAC- PAC- PAC- PACSG38 SH59 SH88 SH89 SH90 KE92 KE93 KE94 KE95 1001 SA1 SF1 SH51
KF-E KF-E KF-E KF-E KF-E TB-E TB-E TB-E TB-E CL-E ME-E ME-E SP-E
MSZ-FH25VE2
MSZ-FH35VE2
MSZ-FH50VE2
MSZ-EF18VE3(W)(B)(S)
MSZ-EF22VE3(W)(B)(S)
MSZ-EF25VE3(W)(B)(S)
MSZ-EF35VE3(W)(B)(S)
MSZ-EF42VE3(W)(B)(S)
MSZ-EF50VE3(W)(B)(S)
MSZ-SF15VA
MSZ-SF20VA
MSZ-SF25VE3
MSZ-SF35VE3
MSZ-SF42VE3
MSZ-SF50VE3
MSZ-GF60VE2
MSZ-GF71VE2
MSZ-DM25VA
MSZ-DM35VA
MSZ-HJ25VA
MSZ-HJ35VA
MSZ-HJ50VA
MSZ-HJ60VA
MSZ-HJ71VA
MFZ-KJ25VE2
MFZ-KJ35VE2
MFZ-KJ50VE2
MLZ-KA25VA
MLZ-KA35VA
MLZ-KA50VA
SLZ-KF25VA2
SLZ-KF35VA2
SLZ-KF50VA2
SLZ-KF60VA2
SEZ-KD25VAQ/VAL
SEZ-KD35VAQ/VAL
SEZ-KD50VAQ/VAL
SEZ-KD60VAQ/VAL
SEZ-KD71VAQ/VAL
PLA-RP35BA
PLA-RP50BA
PLA-RP60BA
PLA-RP71BA
PLA-RP100BA
PLA-RP125BA
PLA-RP140BA2
PLA-ZRP35BA
PLA-ZRP50BA
PLA-ZRP60BA
PLA-ZRP71BA
PLA-ZRP100BA
PLA-ZRP125BA
PLA-ZRP140BA
PEAD-RP35JAQ
PEAD-RP35JALQ
PEAD-RP50JAQ
PEAD-RP50JALQ
PEAD-RP60JAQ
PEAD-RP60JALQ
PEAD-RP71JAQ
PEAD-RP71JALQ
PEAD-RP100JAQ
PEAD-RP100JALQ
PEAD-RP125JAQ
PEAD-RP125JALQ
PEAD-RP140JAQ
PEAD-RP140JALQ
PEA-RP200GAQ
PEA-RP250GAQ
PEA-RP400GAQ
PEA-RP500GAQ
PKA-RP35HAL
PKA-RP50HAL
PKA-RP60KAL
PKA-RP71KAL
PKA-RP100KAL
PCA-RP35KAQ
PCA-RP50KAQ
PCA-RP60KAQ
PCA-RP71KAQ
PCA-RP100KAQ
PCA-RP125KAQ
PCA-RP140KAQ
PCA-RP71HAQ
PSA-RP71KA
PSA-RP100KA
PSA-RP125KA
PSA-RP140KA
*1 P Series indoor units can be used in combination with SUZ or MXZ outdoor units. *2 MAC-333IF-E or MAC-397IF-E is required. *3 Unable to use with wireless remote controller.
*4 Two interface components required for each indoor unit. *5 Refrigerant address must be set to 00. *6 PAC-SH29TC-E is required. *7 Group control cannot be used.
119
PACSH53
TM-E
Fresh-air
Intake Duct
Flange
PACSH65
OF-E
Space
Panel
Drain Pump
MA &
System
Decorative Control Contact Wi-Fi
Terminal
Cover Interface
Interface
Interface
Power Supply
Terminal Kit
Terminal
Block kit
for PKA
Controller
Signal
Sender
PAC- PAC- PAC- PAC- PAC- PAC- PAC- PACPAR- PAR- PARPACPACMAC- MAC- MACMACMAC- PAC- PAC- PAC- PAC- PARSH94 SH75 SH83 SH84 SH85 KE07 SF81 SF82
333IF 397IF-E 557IF-E 1702RA-E 1710RA-E SG94 SG96 SG97 SH52 32MAA YT52CRA SH29TC-E SL97 SL100 SA9C
DM-E DM-E DM-E DM-E DM-E DM-E KC-E KC-E
HR-E HR-E HR-E HR-E
A-E A-E
A-E
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
VAQ
VAQ
VAQ
VAQ
VAQ
PARSF9
FA
PARSA9F
A-E
PARSL94
B-E
MAC1200
RC
PACSE41
TS-E
PACSE55
RA-E
PACSF40
RM-E
*7
*3
*7
*3
*7
*3
*7
*3
VAQ
VAQ
VAQ
VAQ
VAQ
PACSA88
HA-E
*3
*3
*3
*3
*3
*1
*1
*1
*1
*3
*1
*1
*3
*1
*1
*3
*1
*1
*3
*3
*3
*3
*1
*1
*3
*1
*1
*3
*1
*1
*3
*1
*1
*3
*1
*1
*3
*1
*1
*3
*1
*1
*3
*1
*1
*3
*1
*1
*3
*1
*1
*3
*1
*1
*3
*1
*1
*3
*1
*1
*3
*1
*1
*3
*1
*1
*3
*1
*1
*3
*1
*1
*3
*1
*1
*3
*1
*1
*3
*1
*1
*3
*1
*1
*3
*1
*1
*1
*1
*3
*3
*4
*5
*4
*5
*1
*1
*6
*6
*1
*1
*6
*6
*1
*1
*6
*6
*1
*1
*6
*6
*1
*1
*6
*6
*1
*1
*3
*1
*1
*3
*1
*1
*3
*1
*1
*3
*3
*3
*3
*3
*3
*3
*3
*3
120
Option
For
Twin
(50:50)
MSDD50TR-E
Outdoor Unit
F Series
E Series
M SERIES
S Series
G Series
D Series
H Series
Compact
floor
S SERIES
POWERFUL
HEATING
P SERIES
Power
Inverter
Standard
Inverter
MXZ SERIES
MUZ-FH25VE
MUZ-FH25VEHZ
MUZ-FH35VE
MUZ-FH35VEHZ
MUZ-FH50VE
MUZ-FH50VEHZ
MUZ-EF25VE
MUZ-EF25VEH
MUZ-EF35VE
MUZ-EF35VEH
MUZ-EF42VE
MUZ-EF50VE
MUZ-SF25VE
MUZ-SF25VEH
MUZ-SF35VE
MUZ-SF35VEH
MUZ-SF42VE
MUZ-SF42VEH
MUZ-SF50VE
MUZ-SF50VEH
MUZ-GF60VE
MUZ-GF71VE
MUZ-DM25VA
MUZ-DM35VA
MUZ-HJ25VA
MUZ-HJ35VA
MUZ-HJ50VA
MUZ-HJ60VA
MUZ-HJ71VA
MUFZ-KJ25VE
MUFZ-KJ25VEHZ
MUFZ-KJ35VE
MUFZ-KJ35VEHZ
MUFZ-KJ50VE
MUFZ-KJ50VEHZ
SUZ-KA25VA5
SUZ-KA35VA5
SUZ-KA50VA5
SUZ-KA60VA5
SUZ-KA71VA5
PUHZ-SHW112VHA
PUHZ-SHW112YHA
PUHZ-SHW140YHA
PUHZ-ZRP35VKA
PUHZ-ZRP50VKA
PUHZ-ZRP60VHA
PUHZ-ZRP71VHA
PUHZ-ZRP100VKA2
PUHZ-ZRP100YKA2
PUHZ-ZRP125VKA2
PUHZ-ZRP125YKA2
PUHZ-ZRP140VKA2
PUHZ-ZRP140YKA2
PUHZ-ZRP200YKA
PUHZ-ZRP250YKA
PUHZ-P100VHA4
PUHZ-P125VHA3
PUHZ-P140VHA3
PUHZ-P200YKA
PUHZ-P250YKA
PUHZ-P100YHA2
PUHZ-P125YHA
PUHZ-P140YHA
MXZ-2D33VA
MXZ-2D42VA2
MXZ-2D53VA (H)2
MXZ-2E53VAHZ
MXZ-3E54VA
MXZ-3E68VA
MXZ-4E72VA
MXZ-4E83VA
MXZ-4E83VAHZ
MXZ-5E102VA
MXZ-6D122VA
MXZ-2DM40VA
MXZ-3DM50VA
MSDD50WR-E
Unit
For
For
6.35
Triple
Quadruple
-->
(33:33:33) (25:25:25:25) Pipe
9.52
Unit
9.52
-->
Pipe
12.7
Unit
15.88
-->
Pipe
19.05
PACSG72
RJ-E
PACSG73
RJ-E
PACSG75
RJ-E
MSDT111R-E
MSDF1111R-E
Unit
9.52
-->
Pipe
15.88
Joint Pipe
Unit
6.35
-->
Pipe
9.52
*1 Operation in AUTO step mode only: make sure to turn OFF SW2-6 and put TH5 (2 phose pipe thermistor) at the appropriate position.
121
Unit
12.7
-->
Pipe
9.52
Unit
12.7
-->
Pipe
15.88
For
pipe
6.35
For
pipe
9.52
For
pipe
12.7
PACSG82
DR-E
PACSG85
DR-E
Step Interface
Air Outlet Guide
Drain Socket
Freezeprevention
Heater
(for Drain Pan)
PAC645
BH-E
PACIF01
MNT-E
M-NET
Converter
Insulation
Control/
1 PC board
for
Service
/ attachment kit Accumlator
Tool wattachment
kit
PACIF012B-E
*1
*1
*1
*1
*1
*1
*1
*1
*1
*1
*1
*1
*1
122
External Dimensions
Unit : mm
MSZ-EF18VE3(W)(B)(S) MSZ-EF22VE3(W)(B)(S)
MSZ-EF25VE3(W)(B)(S) MSZ-EF35VE3(W)(B)(S)
MSZ-EF42VE3(W)(B)(S) MSZ-EF50VE3(W)(B)(S)
INDOOR UNIT
925
885
875
57 or more
Air in
Installation plate
Air out
117
59
132
18
158
678
18
MSZ-GF60VE2 MSZ-GF71VE2
1100
1090
10
Installation plate
238
Air in
5
47
( 80 )
92
Drain hose
76
843
108.5
181
Air out
60
18
67
65
( 70)
Air out
193
18
Installation plate
Piping
12
160
58
577
100
325
299
Piping
125
160
184
Air in
100
778
193
Air out
INDOOR UNIT
798
123
Drain hose
110
193
INDOOR UNIT
60
47
94
(80)
60
61
Piping
7
Drain hose
193
60
35 or more
299
101
160
Installation
plate
100
51
56
39
35 or more
7 or more
704
100
25
61
Air in
17
Piping
In case of left,
left back,or
left under piping
(using spacer),
111 or more.
10
58
905
Drain hose
MSZ-DM25VA MSZ-DM35VA
INDOOR UNIT
799
INDOOR UNIT
799
785
46
46
785
Unit : mm
Air in
Air in
Installation plate
Installation plate
100
14
7
100
14
7
57
290
Piping
57
290
Piping
42
120
Air out
630
120
57
18
172
18
132
MSZ-SF15VA MSZ-SF20VA
MSZ-HJ60VA MSZ-HJ71VA
INDOOR UNIT
INDOOR UNIT
923
909
130
Air out
172
Drain hose
140
56
49
130
103
)
7
(5
630
)
7
(5
49
42
Drain hose
103
760
740
10
Air in
Installation plate
146
65
114
Drain hose
56
505
41
179
Air out
18
60
110
Drain hose
18
193
140
57
161
Air out
Installation plate
Piping
56
709
65
53
250
100
7
305
Piping
168
124
Unit : mm
Remote controller
No obstruction
47
28
215
Air out
70
More than
100mm
Gas pipe
25/35: 9.52 (flared) 3/8
50: 12.7 (flared) 1/2
Liquid pipe
6.35 (flared) 1/4
148
15
15
600
More than
100mm
26
750
656
47
19
193
60
Less than
150mm
127
12
60
104
131
153
Drain
47
656
47
125
30
60
Air in
165
205
303
Sensor hole
(Top)
16
38
15
54.5
20
110
112
110
116
Gas pipe
Liquid pipe
Pipe cover
0.04m2
60
Ceiling
surface
Display and
No
gaps
between
58
receiving section
the ceiling surface and grille
48
31
25
Drain pan
Grille (MLP-440W)
34
1200
Receiving section
CL
R6
172.4
166.5
CL
R6
125
466.5
0
10
166.5
173
414
81.8
0
54.5
20
(Front)
175
170
Drain pipe
Electrical box
244
78
180 or more
960
Outlet
360
Drain hose
175
Drain hose
1102
Air outlet
(Right side)
(Front)
158
26
15
18
15
230
180
(51.6)
Drain hose
connecting part
Air outlet
58
26
Pipe
cover
Electrical box
16
308
Suspension bolt pitch
2
2
Wireless
remote controller
38
13.5
58
49.7
Ceiling surface
Grille
Ceiling surface
MUZ-SF25VEH
MUZ-SF42VE
MUZ-SF35VE
MUZ-SF42VEH
417.5
360
Air out
175
Air out
500
840
17.5
40
21
42
50
Drain hole
Air in
2 holes 10
Drain hole
40
Air in
44
285
MUZ-FH50VE MUZ-FH50VEHZ
MUZ-EF50VE
MUZ-SF50VE MUZ-SF50VEH
MUZ-GF60VE MUZ-GF71VE
MUZ-HJ60VA MUZ-HJ71VA
MUFZ-KJ50VE
MUFZ-KJ50VEHZ
OUTDOOR UNIT
MUFZ-KJ35VE
MUFZ-KJ35VEHZ
400
Air in
344.5
Unit : mm
MUZ-FH35VE
MUZ-FH35VEHZ
MUZ-EF25VEH
MUZ-EF35VEH
330
MUZ-FH25VE
MUZ-FH25VEHZ
MUZ-EF25VE
MUZ-EF35VE
MUZ-EF42VE
MUZ-SF25VE
MUZ-SF35VEH
MUZ-HJ50VA
MUFZ-KJ25VE
MUFZ-KJ25VEHZ
OUTDOOR UNIT
2-holes 10 21
81
109
Service panel
23
22.3
Service panel
Liquid refrigerant
pipe joint
Refrigerant pipe
Liquid refrigerant
pipe joint
Refrigerant pipe
Service port
164.5
99.5
Gas refrigerant
pipe joint
Refrigerant pipe
452
35
99.5
10
164.5
280
302.5
170.5
44
69
35
150
43
550
880
Handle
195
Gas refrigerant
pipe joint
Refrigerant pipe
MUZ-DM25VA MUZ-DM35VA
MUZ-HJ25VA MUZ-HJ35VA
OUTDOOR UNIT
Air in
19.6
Air in
285
41.5
Drain hole 33
Air out
349.5
17.9
249
102.7
13.5
157.7
40
43
270.3
538
121
259
500
699
121.4
55.7
126
Unit : mm
SLZ-KF25VA2 SLZ-KF35VA2
SLZ-KF50VA2 SLZ-KF60VA2
INDOOR UNIT
Models
SLZ-KF25VA2
SLZ-KF35VA2
9.52mm
flared connection 3/8F
63mm
72mm
SLZ-KF50VA2
6.35mm
flared connection 1/4F
12.7mm
flared connection 1/2F
63mm
78mm
SLZ-KF60VA2
6.35mm
flared connection 1/4F
15.88mm
flared connection 5/8F
63mm
78mm
20
12
157.5
37 100
37
23
10
625 (Suspension bolt pitch)
49
H
100XJ=K
L- 2.9
90
2XE- 2.9
20
12
57
20
30
25
88
100
100
Air
inlet
Air
outlet
D (Duct)
100X(E-1)=F
88
15
Air filter
2X2- 2.9
Refrigerant piping
flare connection (gas)
116
70
270
200
170
Terminal block
Terminal block (Indoor/outdoor connecting line)
(Remote controller transmission line)
Notes:
Model
A
B
C
D
SEZ-KD25VAL/VAQ 700 752 798 660
SEZ-KD35VAL/VAQ
900 952 998 860
SEZ-KD50VAL/VAQ
SEZ-KD60VAL/VAQ
1100 1152 1198 1060
SEZ-KD71VAL/VAQ
127
Knockout hole 27
(Indoor/outdoor connecting line)
4-14X30 Slot
Control box
102
23
10
100
150 (Duct)
23
25
Refrigerant piping
flare connection (liquid)
E
7
Knockout hole 27
(Remote controller transmission line)
F
600
G
800
H
660
J
5
K
500
L
16
800
1000
860
700
20
11
900
24
SUZ-KA25VA5 SUZ-KA35VA5
OUTDOOR UNIT
Drain hole
44
Air in
40
2 holes 10X21
17.5
Service panel
Air out
22.3
23
Liquid refrigerant pipe joint
Refrigerant pipe (flared)
150
69
302.5
10
164.5
280
35
550
Handle
43
285
400
Air in
344.5
Unit : mm
170.5
Service port
128
Unit : mm
PKA-RP35HAL PKA-RP50HAL
INDOOR UNIT
INDOOR UNIT
20~45
Ceiling hole
620
860~910
840
605
160
Remote controller
terminal block
Indoor unit/Outdoor
unit connecting
terminal block
197
20~45
(7.5)
160
Top side
20~45
860~910
810
Fresh air
intake hole
192
387
950
Ceiling hole
599
Mounting board
160
24
160
840
Suspension bolt
M10 or W3/8
Drain pipe
377
90
100
90
155
55
167
190
156
140
105
70
Refrigerant pipe
(gas)
688
249
155
Models
80
74
241 258
Models
400
87
PLA-ZRP35BA
PLA-ZRP50BA
PLA-ZRP60BA
PLA-ZRP71BA
PLA-ZRP100BA
PLA-ZRP125BA
PLA-ZRP140BA
350
175
Keep approximately
10 to 15mm space
between unit ceiling
and ceiling slab.
PLA-RP35/50BA
PLA-RP60BA
Ceiling
Grille
35
17 +50
898
50~70
170
100
100
60
130
Refrigerant pipe
(liquid)
Suspension bolt
lower edge
295
20~45
187.5
Right side
(7.5)
90
150
Front side
150
14- 2.8
Burring hole
241 258
C
80
74
400
77
440
87
281 298 85
PLA-RP71BA
PLA-RP100,125BA
PLA-RP140BA2
281 298
85 77
440
PCA-RP35KAQ PCA-RP50KAQ
INDOOR UNIT
INDOOR UNIT
51
431.7
Top side
960
10
853
230
195
140.3
84 88
65.2
423.7
11
Air outlet
184
203
233
246
Right side
254
365
476
680
Front side
57
Mounting board
74
(855)
241
295
182
878
1170
Air intake
129
85
(liquid (
(gas (
drain socket (
( When
is installed
(Drainage)
PCA-RP60KAQ PCA-RP71KAQ
Unit : mm
INDOOR UNIT
INDOOR UNIT
51
51
10
1600
1493
Air outlet
(gas)
When drain socket
is installed
(Drainage)
233
233
246
(liquid)
(gas)
When drain socket
is installed
(Drainage)
254
A
B
254
476
476
680
680
57
246
180
200
Air outlet
(liquid)
10
5
84 88
195
230
236
230
195
84 88
236
1173
57
1280
60
71
179
203
180
200
182
85
1518
182
85
Air intake
1198
Air intake
PCA-RP71HAQ
INDOOR UNIT
INDOOR UNIT
38
10
Knockout hole
for branch duct
10
132
100
130
Front side
125
340
370
Metal fixture
against overturning
520
260
240
360
10
40
20
40
<gas>
197
15
240
111
38 15
21
<liquid>
130
110
175
Rear side
Suspension bolt
495
75
320
260
1224
1180
80
75
140
70~90
289
650
Inspection port
(pipe sensor)
71
1900
1136
130
129
820
outlet>
254
295
43
70
986 <Air
Controller
13
243
75
280
102
110
<Air outlet>
<Flexible hose(accessory)>
115
181
50
834
599
30
70
524
600
260
310
130
2xE- 2.9
D (Duct)
100x(E-1)=F
Air
inlet
Air
outlet
Air
outlet
Air
inlet
57 20
30
PEAD-RP35,50JAQ
PEAD-RP60,71JAQ
PEAD-RP100,125JAQ
PEAD-RP140JAQ
900
954
1000
860
800
1100
1400
1600
1154 1200
1454 1500
1654 1700
1060
1360
1560
11
14
16
1000
1300
1500
23
732
700
Terminal block
(Remote controller
transmission line)
217
10
Refrigerant piping
Flare connection (gas)
Model
PEAD-RP35,50JALQ
PEAD-RP60,71JALQ
PEAD-RP100,125JALQ
PEAD-RP140JALQ
250
32
122
40
100
178(Duct)
23
Drain pipe
Terminal block
(Spontaneous draining) (Indoor/Outdoor
connecting line)
D
E
F
57
Refrigerant piping
Flare connection (liquid)
2 2- 2.9
67
356
136
Model
131
250
Control box
2 2- 2.9
Refrigerant piping
Flare connection (gas)
10
33
41
217
100
238
10
33
122
32
23
40
178(Duct)
Terminal block
(Remote controller
transmission line)
732
700
24
57
Refrigerant piping
Flare connection (liquid)
23
10
58
40
57 20
30
100
100
D (Duct)
100x(E-1)=F
15
2xE- 2.9
15
INDOOR UNIT
Unit : mm
Control box
136
67
356
Drain pipe
900
954
1000
860
800
1100
1400
1600
1154
1454
1654
1200
1500
1700
1060
1360
1560
11
14
16
1000
1300
1500
Terminal block
(Indoor/Outdoor
connecting line)
131
95
89
35
Refrigerant pipe
(Liquid)
Supply air
1284
Left view
462
10
39
565
199
1500
20
40
Fresh-air
intake duct 45
flange
130
7x130(=910)
4- 12
45 <For hanging bolt M10>
[Field supply]
Top view
40
54
10
255
1600
1540
1460
1000
40
205
95
634
530
Return air
sensor
Supply air
1484
Drain
Left view
Drain
Refrigerant pipe
(liquid)
250
Return air
11
565
40
105
400
376
100 100 25
155
25
39
40
54
10
73
A
89
35
Return air
634
530
262
330
22
145 144
130 130 35
Return air
sensor
50
Refrigerant pipe
10
(gas)
26- 3 Holes
20
A
Refrigerant pipe
50
(gas)
10
1400
1340
1260
1000
Return air
duct flange
250
7x130(=910)
Top view
4- 12
45 <For hanging bolt M10>
[pwehase locally]
376
130
34
66
130
22- 3.1
55
73
Fresh-air
intake duct 45
flange
Rubber bushing
<Power supply
wiring>
10
40
100 100 25
20
22- 3.1
70 75 129
199
1300
262
20
1302
9X130(=1170)
Control box
Rubber bushing
<Remote
controller wiring>
Rubber bushing
<Outdoor unit
connection wiring>
25
10
Control box
55
Return-air
duct flange
24- 3 Holes
462
Rubber bushing
<Power supply wiring>
130
100
70 75 129
Rubber bushing
<Outdoor unit
connection wiring>
124
66
100
34
31
42
400
1102
8x130(=1040)
330
22
145 144
130 130 35
124
31
42
<Accessory>
Pipe cover....................2pcs.
(For dew condensation prevention of local piping and unit connection)
Remote controller.........1pc.
200
<Accessory>
Pipe cover....................2pcs.
(For dew condensation prevention of local piping and unit connection)
Remote controller........1pc.
200
INDOOR UNIT
131
INDOOR UNIT
Unit : mm
10
PEA-RP250GAQ
11
PEA-RP200GAQ
Front view
Front view
PEA-RP400GAQ PEA-RP500GAQ
INDOOR UNIT
149
29
1618
33
29
12X130(=1560)
130
100
40
Return-air
duct flange
203
36- 3 HOLES
61
60 60 60
45
10
<Accessory>
Pipe cover...................4pcs.
(For dew condensation prevention of local piping and unit connection)
Remote controller.......1pc.
425
20
1840
Rubber bushing
<Outdoor unit connection wiring>
20
Fresh-air intake
duct flange
130
42.5
8X130(=1040)
10
59
141
24- 3.1
320
Control box
Rubber bushing
<Remote controller wiring>
Rubber bushing
<Power supply wiring>
4- 15
42.5 <For hanging bolt M12>
[Field supply]
Top view
764
664
Return air sensor
(2 places)
395
1947
1880
1800
1125
Left view
280
40
340
595
570
Supply air
22
A
700
40
130 130
39
Drain
Refrigerant pipe
(liquid)
40
40
120
525
102
22.5
Return air
50
10
188
50
10
4X120(=480)
117 156 117
22
22.5
81
1824
Front view
132
PUHZ-SHW80VHA PUHZ-SHW112VHA
PUHZ-SHW112YHA PUHZ-SHW140YHA
Unit : mm
PUHZ-ZRP35VKA PUHZ-ZRP50VKA
OUTDOOR UNIT
OUTDOOR UNIT
Rear Air Intake
175
600
175
(19)
Installation Feet
SHWVHA
1079
SHWYHA
930
Air intake
42 drain hole
Air intake
Air discharge
950
322
32.5
42
53
28
30
66
Air Discharge
40
Terminal connection
Left Power supply wiring
Right Indoor/Outdoor wiring
Earth terminal
Terminal connection
Left
Power supply wiring
Indoor/Outdoor wiring
Right
Earth terminal
Service panel
630
Connection for
liquid pipe
FLARE 6.35 (1/4F)
371
1 443
1 447
8.5
320
Connection for
gas pipe
FLARE 12.7 (1/2F)
154.5
310
Installation bolt pitch
500
809
OUTDOOR UNIT
600
225
175
19
175
Installation Feet
62
225
(19)
PUHZ-ZRP60VHA PUHZ-ZRP71VHA
Service port
23
Service panel
for charge plug
Service panel
635
1350
Handle
for
moving
360
300
330
417
45
56
370
330
48
404.5
41
370
417
330
Air Discharge
75
28
61
42
2-1236 Oval holes
(foundation bolt M10)
28
362
1050
Earth terminal
Terminal connection
Left...Power supply wiring
Right..Indoor/Outdoor wiring
Air discharge
950
Handle for moving
322
Earth terminal
56
40
0
53
Terminal connections
Left:Power supply wiring
Right : Indoor / Outdoor wiring
Service panel
Service panel
1338
632
Air Intake
57
53
30
40
417
370
40
54
330
23
Model
Front piping cover
Rear piping cover
133
26
447
431
473
673
369
943
PUHZ-ZRP100~140YKA2.UK
Model
PUHZ-ZRP100~140VKA2.UK
PUHZ-ZRP100~140YKA2.UK
1
2
Refrigerant GAS pipe Refrigerant LIQUID pipe
connection
connection
15.88 (5/8F)
A
1067
919
B
442
442
9.52 (3/8F)
C
450
450
OUTDOOR UNIT
OUTDOOR UNIT
Rear Air Intake
(19)
600
Installation Feet
370
417
56
40
0
53
30
1050
Air Discharge
Earth terminal
362
370
417
E
F
28
61
42
2-12 36 Oval holes
(foundation bolt M10)
330
40
75
Air Discharge
175
(19)
175
Terminal connection
Left...Power supply wiring
Right...Indoor/Outdoor wiring
950
322
28
225
53
600
Installation Feet
225
Unit : mm
PUHZ-P100VHA4 PUHZ-P100YHA2
PUHZ-ZRP200YKA PUHZ-ZRP250YKA
Terminal Connections
LeftPower supply wiring
RightIndoor/Outdoor wiring
Earth terminal
Service panel
Service panel
Air Intake
1 985
943
1338
632
1 A
1 447
473
3 450
3 442
26
369
2 342
BRAZING
23
1
2
Refrigerant GAS pipe Refrigerant LIQUID pipe
connection
connection
Model
PUHZ-ZRP200YKA.UK
PUHZ-ZRP250YKA.UK
19.05 (3/4F)
9.52 (3/8F)
19.05 (3/4F)
12.7 (1/2F)
D
42
41
E
45
41
F
56
54
PUHZ-P125VHA3 PUHZ-P140VHA3
PUHZ-P125YHA PUHZ-P140YHA
175
OUTDOOR UNIT
175
225
(19)
Installation Feet
225
600
(19)
OUTDOOR UNIT
PUHZ-P200YKA PUHZ-P250YKA
Installation Feet
322
61
42
417
1050
362
950
75
Air Discharge
56
40
0
53
28
330
417
40
41
53
28
41
54
370
330
30
56
Air Discharge
370
Earth terminal
Terminal connection
LeftPower supply wiring
RightIndoor/Outdoor wiring
Earth terminal
Terminal connection
LeftPower supply wiring
RightIndoor/Outdoor wiring
Service panel
632
1338
Service panel
1 985
3 450
26
3 442
2 342
369
1 447
1 431
371
Air Intake
635
BRAZING
23
1350
1
Handle for moving
A
PUHZ-P125/140VHA3 1076
PUHZ-P125/140YHA
994
Model
PUHZ-P200YKA.UK
PUHZ-P250YKA.UK
1
2
Refrigerant GAS pipe Refrigerant LIQUID pipe
connection
connection
19.05 (3/4F)
9.52 (3/8F)
19.05 (3/4F)
12.7 (1/2F)
134
400
Unit : mm
MXZ-2E53VAHZ
OUTDOOR UNIT
17.5
40
Air out
280
51 51 51
18
13
B unit
connection
A unit
connection
170.4
302.5
10
285
251.1
550
22.3
Handle
344.5
Air in
304~325
Air in
500
69
MXZ-4E72VA
MXZ-3E54VA2 MXZ-3E68VA
MXZ-3DM50VA
OUTDOOR UNIT
171
17.7
Air in
17.7
4-1021 Oval hole
(Foundation bolt M8)
840
200
30
330
840
25.8
330
13
240
Connecting
Wire Hole
C unit
connection
315
A unit
connection
710
B unit
connection
45
27.1 (3927)
360
710
440
225
84
45
23.1
84
360
30
200
66.3
299
135
13
27.1
Connecting
Wire Hole
(3927)
299
Air out
240
Air out
171
314
12.3
12.3
Air in
207.5
18.3
360.6
(Bolt Pitch)
396
360.6
(Bolt Pitch)
396
18.3
65.4
17.7
Air in
500
169
314
34
16.6
500
207.5
16.6
169
65.4
17.7
OUTDOOR UNIT
23.1
440
800
34
150
66.3
Liquid pipe : 6.35(flared)1/4
Gas pipe : 9.52(flared)3/8
Liquid pipe : 6.35(flared)1/4
Gas pipe : 9.52(flared)3/8
Liquid pipe : 6.35(flared)1/4
Gas pipe : 9.52(flared)3/8
Liquid pipe : 6.35(flared)1/4
Gas pipe : 12.7(flared)1/2
D unit
connection
C unit
connection
B unit
connection
A unit
connection
MXZ-4E83VA MXZ-5E102VA
MXZ- 4E83VAHZ
OUTDOOR UNIT
OUTDOOR UNIT
Unit : mm
Rear Air
Intake
175
600
250
71
80
97
175
2-U Shaped Notched Hole
116
51
417
134
370
(Bolt Pitch)
62
40
10
16
10
Air
Discharge
10
31
10
51
10
6- 33 Drain Hole
25
950
330
15
Handle
Handle
1048
Handle
70
563
LIQ
GAS
LIQ
GAS
LIQ
GAS
LIQ
GAS
Unit D
Unit C
LIQ 6.35(1/4")FLARE
GAS 9.52(3/8")FLARE
Unit B
Unit A
LIQ 6.35(1/4")FLARE
GAS 12.7(1/2")FLARE
Air Intake
361
MXZ-6D122VA
OUTDOOR UNIT
Air in
175
16
370
Air out
10
31
10
51
10
417
10
36
10
Air in
600
250 80 97 116
134
62
40
71
51
10
(Bolt pitch)
175
950
25
330
15
Handle
Handle
563
1048
Handle
70
Liquid pipe : 6.35(flared)1/4
Gas pipe : 9.52(flared)3/8
Liquid pipe : 6.35(flared)1/4
Gas pipe : 9.52(flared)3/8
Liquid pipe : 6.35(flared)1/4
Gas pipe : 9.52(flared)3/8
Liquid pipe : 6.35(flared)1/4
Gas pipe : 9.52(flared)3/8
Liquid pipe : 6.35(flared)1/4
Gas pipe : 9.52(flared)3/8
Liquid pipe : 6.35(flared)1/4
Gas pipe : 12.7(flared)1/2
F unit
connection
E unit
connection
D unit
connection
C unit
connection
B unit
connection
A unit
connection
Air Intake
361
136
PUMY SERIES
PUMY-P112/125/140VKM2(-BS)
PUMY-P112/125/140YKM2(-BS)
Unit : mm
PAC-MK51BC
Suspension bolt: W3/W8 (M10)
OUTDOOR UNIT
Branch box
Rear Air Intake
600
Installation Feet
225
19
225
330
370
417
25
42
56
2-1236 Oval holes
(Foundation Bolt M10)
24
28
12
Terminal connection
From left to right
1050
Ground for the power supply
("GR"marking position)
For the
branch box
power supply
For the
power supply
For the
transmission line
For concentration
control
67
632
1338
170
65 47
25 25 25 25
70 70 70 70
Service panel
(for lev. thermistor)
*1 426
*1 510
26
154
86
136
110 160
160
160
Drain hole
(5-33)
Example of Notes
Refrigerant GAS pipe connection (FLARE) 15.88 (5/8F)
Refrigerant LIQUID pipe connection (FLARE) 9.52 (3/8F)
Indication of STOP VALVE connection location.
Model
PUMY-P112/125/140VKM2(-BS)
1062
PUMY-P112/125/140YKM2(-BS)
909
PAC-MK31BC
PAC-MK51BCB
Branch box
Branch box
Suspension bolt pitch
320
24
24
402
Suspension bolt pitch
402
Suspension bolt pitch
12
12
25
25
25
70 70 70 70
To outdoor unit
3/8F
5/8F
Control cover
Bush
To outdoor unit
Service panel
(for lev. thermistor)
Terminal block
to indoor unit
TB3E
25
Terminal block
to M-net unit
119
TB3D
70
5-electric wire
inlet
TB2B
25
87
40
TB3B
280
112
To indoor unit
67
113
TB3C
137
Terminal block
to outdoor unit
119
TB5
450
TB3A
Control cover
Bush
To outdoor unit
Service panel
(for lev. thermistor)
Terminal block
to indoor unit
TB2B
Terminal block
to M-net unit
5-electric wire
inlet
TB3B
25 25
70 70
40
170
65 47
87
280
70
TB3C
Cap 25
96
83
TB5
90
72
112
To indoor
unit
TB3A
170
65 47
450
Terminal block
to outdoor unit
Control cover
Bush
To outdoor unit
45
209
Cap
TB3E
369
Terminal block
to indoor unit
5-electric wire
inlet
TB3D
70
Terminal block
to M-net unit
TB3B
Air Intake
81
87
40
TB2B
83
280
TB3C
25
Service panel
Handle for
moving
Handle for
moving
2
*1
72
96
TB5
Ground for
the branch box
power supply
90
TB3A
450
To indoor unit
112
70
Air Discharge
362
56
33
0
53
Terminal block
to outdoor unit
Unit : mm
PAC-MK31BCB
Suspension bolt: W3/W8 (M10)
Branch box
24
402
Suspension bolt pitch
12
To indoor unit
A C
25
25
70 70
Terminal block
to indoor unit
TB3B
70
Terminal block
to M-net unit
119
TB2B
87
40 5-electric wire
inlet
TB3C
25
280
TB5
113
TB3A
170
65 47
CAP
CAP
119
112
450
209
Control cover
Bush
To outdoor unit
Terminal block
to outdoor unit
Service panel
(for lev. thermistor)
To outdoor unit
9.52
15.88
138
Piping Installation
Single type
Class
< Outdoor unit>
Series
Total number
MSZ-F
MFZ-KJ
25 / 35
20
12
50
30
15
10
MSZ-E
25 / 35 / 42
20
12
10
50
30
15
10
MSZ-S
25 / 35 / 42
20
12
10
50
30
15
10
60 / 71
30
15
10
MSZ-D
25 / 35
20
12
10
MSZ-H
25 / 35 / 50
20
12
10
60 / 71
30
15
10
MSZ-G
10
&
Single type
Class
<Outdoor unit>
Series
ZUBADAN (PUHZ-SHW)
POWER INVERTER (PUHZ-ZRP)
STANDARD INVERTER
(PUHZ-P & SUZ)
Total number
80 / 112 / 140
75
30
15
35 / 50 / 60 / 71
50
30
15
75
30
15
200 / 250
100
30
15
25 / 35
20
12
10
50 / 60 / 71
30
30
10
50
30
15
200 / 250
70
30
15
Twin type
Class
<Outdoor unit>
Series
ZUBADAN (PUHZ-SHW)
POWER INVERTER (PUHZ-ZRP)
75
15
71
50
20
30
15
75
20
30
15
200 / 250
100
30
30
15
50
20
30
15
200 / 250
70
30
30
15
140
75
100
30
30
15
140
50
20
30
15
200 / 250
70
28
30
15
22
30
200 / 250
100
200 / 250
70
Triple type
Total length
A+B+C+D+E
Twin type
B
h
H
A
139
Distribution
pipe
Quadruple type
h
C
Distribution
pipe
15
Closest
& Lowest
Total number
200 / 250
Total length
A+B+C+D
Class
<Outdoor unit >
Single type
Total number
Quadruple type
Series
30
20
Class
<Outdoor unit>
80 / 112 / 140
Triple type
Series
Total length
A+B+C
Closest
& Lowest
D
E
Distribution
pipe
MXZ-2D33VA
15m
Indoor
units
Maximum height
difference
20m
Outdoor
unit
Outdoor unit
|
Indoor unit
10m
*Outdoor unit
installed lower
15
Indoor unit
|
Indoor unit
20
10m
* When connecting MFZ-KJ Series indoor unit, additional refrigerant is required. For details, please contact Mitsubishi
Electric.
Outdoor unit
|
Indoor unit
Regarding MXZ-2D33, the second unit should be a different type in the case of selecting one MFZ-KJ.
10m
*Outdoor unit
installed higher
MXZ-2D42VA2
20m
Indoor
units
Maximum height
difference
30m
Outdoor
unit
20
MXZ-3E54VA
Indoor unit
15m
*Outdoor unit
installed lower
30
Indoor unit
|
Indoor unit
15m
Outdoor unit
MXZ-2D53VA(H)2, MXZ-2E53VAHZ
Outdoor unit
Indoor unit
10m
*Outdoor unit
installed higher
20m
30m
* When connecting MFZ-KJ Series indoor unit to MXZ-2D42VA2 or MXZ-2D53VA(H)2, additional refrigerant
is required. For details, please contact Mitsubishi Electric.
20
30
Indoor
units
Highest
Maximum height
difference
25m
50m
Outdoor
unit
Outdoor unit
|
Indoor unit
15m
*Outdoor unit
installed lower
25
50
15m
Lowest
25m
Indoor unit
Indoor unit
Outdoor unit
|
Indoor unit
10m
*Outdoor unit
installed higher
60m
* When connecting MFZ-KJ Series indoor unit, additional refrigerant is required. For details, please contact
Mitsubishi Electric.
25
60
140
MXZ-4E72VA
25m
60m
Indoor
units
Highest
25
MXZ-5E102VA
60
Indoor unit
*Outdoor unit
installed lower Indoor unit
|
Indoor unit
15m
Lowest
Outdoor unit
Indoor unit
10m
*Outdoor unit
installed higher
25m
70m
25
70
Indoor
units
Outdoor unit
15m
MXZ-4E83VA, MXZ-4E83VAHZ
Outdoor
unit
* When connecting MFZ-KJ Series indoor unit, additional refrigerant is required. For details, please contact Mitsubishi
Electric.
Maximum height
difference
Highest
25m
80m
Maximum height
difference
a
Outdoor
unit
Outdoor unit
|
Indoor unit
15m
25
*Outdoor unit
installed lower Indoor unit
|
Indoor unit
80
15m
Outdoor unit
Lowest
Indoor unit
10m
d e
*Outdoor unit
installed higher
Highest
MXZ-6D122VA
Indoor
units
25m
80m
25
Outdoor
unit
Outdoor unit
|
Indoor unit
15m
*Outdoor unit
installed lower Indoor unit
|
Indoor unit
15m
80
Outdoor unit
Lowest
Indoor unit
d f
141
Maximum height
difference
10m
*Outdoor unit
installed higher
MXZ-2DM40VA
20m
30m
Indoor
units
(MSZ-HJ*
MSZ-DM*)
Maximum height
difference
Outdoor
unit
20
Outdoor unit
|
Indoor unit
15m
Outdoor unit
installed lower
30
Indoor unit
|
Indoor unit
15m
Outdoor unit
|
Indoor unit
10m
Outdoor unit
installed higher
MXZ-3DM50VA
Indoor
units
(MSZ-HJ*
MSZ-DM*)
25m
50m
Highest
Maximum height
difference
Outdoor
unit
Outdoor unit
|
Indoor unit
15m
Outdoor unit
installed lower
Indoor unit
|
Indoor unit
25
50
15m
Lowest
Outdoor unit
|
Indoor unit
10m
Outdoor unit
installed higher
142
PUMY SERIES
PUMY-P112/125/140V (Y) KM2
1-Branch box
L2
L1
d2
e1
d1
c1
b1
H
a2
a1
a3
Permissible length
(One-way)
Permissible height
difference (One-way)
Number of bends
b2
c2
E
E
h3
a4
a5
a6
h1
a7
a8
Outdoor Unit
First joint
Branch header (CMY)
Branch box (PAC-MK31/51)
CITY MULTI Indoor unit
M/S/P series Indoor unit
e1 + d1 + d2 + c1 + c2 + b1 + b2 + a1 + a2 + a3 + a4 + a5 + a6 + a7 + a8 <
= 300 m
e1 + d2 + a1 or e1 + d1 + c1 + b2 <
= 85 m
e1 + d1 + c1 + b1 + a8 <
= 80 m
e1 + d1 + c1 + b1 <
= 55 m
d1 + c1 + b1 or d1 + c1 + b2 <
= 30 m
a8 <
= 25 m
a4 + a5 + a6 + a7 + a8 <
= 95 m
H<
= 50 m (In case of outdoor unit is set higher than indoor unit)
H<
= 40 m (In case of outdoor unit is set lower than indoor unit)
h1 <
= 15 m
h3 <
= 12 m
|e1 + d2 + a1|, |e1 + d2 + a2|, |e1 + d2 + a3|, |e1 + d1 + c2|, |e1 + d1 + c1 + b2|,
|e1 + d1 + c1 + b1 + a4|, |e1 + d1 + c1 + b1 + a5|, |e1 + d1 + c1 + b1 + a6|,
|e1 + d1 + c1 + b1 + a7|, |e1 + d1 + c1 + b1 + a8| <
= 15
*1: Branch box should be placed within the level between the outdoor unit and indoor units.
2-Branch boxes
L2
L1
c1
d1
B
c2
D
H
a1
a2
a3
Permissible height
difference
(One-way)
Number of bends
h1 a4
Permissible length
(One-way)
h3
a5
*1: Branch box should be placed within the level between the outdoor unit and indoor units.
143
h2
a6
a9
a7
a8
a10
a11
Outdoor Unit
First joint
Branch header (CMY)
Branch box (PAC-MK31/51)
CITY MULTI Indoor unit
M/S/P series Indoor unit
Explanation of Terminology
Maximum piping length:
This is the maximum allowable length of the refrigerant piping. The amount of refrigerant pipe used cannot be longer than the
length specified.
Total length:
The maximum allowable combined length of all the refrigerant piping between the outdoor unit and indoor unit(s).
Outdoor Unit - Indoor Unit:
The maximum allowable length of the refrigerant piping between the outdoor unit and indoor units installed when multiple units are connected to a single outdoor unit. This distance limitation refers to the maximum length between the outdoor unit and the farthest indoor unit.
Pipe length difference from distribution pipe:
The maximum allowable difference in refrigerant piping length from the distribution pipe to the farthest indoor unit and from the distribution
pipe to the closest indoor unit when multiple indoor units are connected to a single outdoor unit using a distribution pipe.
Indoor Unit - Distribution Pipe:
The maximum allowable length of the refrigerant piping between indoor units and the distribution pipe when multiple indoor units are
connected to a single outdoor unit.
144
145
ECODAN
ECODAN can heat rooms and supply domestic
hot water, realising greater comfort and energy saving.
ECODAN Economic, eco conscious next generation heating system
Both energy-saving and safe for the environment, the Mitsubishi Electric ECODAN incorporates a highly efficient heat pump
system that captures the heat in the air, a renewable energy resource. Equipped with advanced inverter control, meticulous
temperature control assures comfortable heating, and its space-saving All-in-one indoor unit is easy to install. These energysaving, high comfort and simple installation characteristics have drawn the ECODAN heating system into the spotlight centre
stage.
INDOOR UNIT
Hydro box, cylinder unit
OUTDOOR UNIT
Packaged type Small capacity ( Under 5kW )*
PUHZ-HW112/140
PUHZ-W50
Split type
PUHZ-W85
PUHZ-W112
Large capacity*
PUHZ-SW50
PUHZ-SW75
PUHZ-SHW80/112/140
PUHZ-SHW230
PUHZ-SW100/120
PUHZ-SW160/200
Eco
Inverter
SUHZ-SW45
PUHZ-FRP71
146
Product label
This label is for individual heating units, such as an ECODAN heat pump. Typically, the space
heater label is used for ECODAN systems with a hydro box, and the combination heater label
is used for ECODAN systems with a cylinder unit.
Heat pump space heater label
Manufacturer
Outdoor and indoor unit
model name
Symbol for
domestic hot water
Heating efficiency in
low-flow temperature operation
Heating efficiency in
medium-flow temperature operation
Indoor and outdoor unit
operating sound power level values
Package label
A heating system can use several energy-related products, such as a controller or solar thermal system. Therefore, a label showing the efficiency of the total heating
system is required. The category range is defined from
A+++ to G.
Creating the package label is the responsibility of the installers and distributors. A useful tool on the Mitsubishi
Electric website is available to easily create the labels for
ECODAN products and controllers.
This label is for heating systems that use several energy-related products, such as a controller
or a solar thermal system.
erp.mitsubishielectric.eu/erp/options
Sample
Sample-1
Sample
Sample-2
A ++
A ++
A+++
A +++
+
+
+
+
A+
C
D
X
X
E
F
2015
A++
811/2013
A+++
A++
A+
A
B
C
D
E
F
G
L
A+++
A++
A+
A
B
C
D
E
F
G
2015
A +++
A +++
811/2013
Customised package labels including ECODAN heat pumps and FTC5 controller
can be created on the Mitsubishi Electric website.
Integrated
capacity (kW)
Mitsubishi Electrics
Flash Injection Technology
The key to high heating
performance at low
outdoor temperatures
A
Heat interchanger (HIC)
B
Injection compressor
147
Previous model
-28C
-20C
-15C
-7C
Outdoor-air temperature at intake duct
0C
The Flash Injection Circuit is an original technology. A heat exchange process at point A
(heat interchanger) transforms liquid refrigerant into a two-phase, gas-liquid state and
then compresses the gas-liquid refrigerant
at point B (injection compressor). This circuit
Outdoor
Indoor
Power
HEX
HEX
secures a sufficient flow rate of refrigerant
receiver
B
for heating when outdoor temperatures are
LEVA
LEVB
very low. Thanks to improving the heat interLEVC
Heat
A
interchanger (HIC) changer and introducing a new injection comRefrigerant flow
pressor, the Flash Injection Circuit is now
Flash Injection Circuit
more powerful.
15
14
13
12
11
10
9
Injection compressor
(injection port)
Indoor units
New all-in-one compact indoor unit
Easy to install and low maintenance
All-in-one: Key functional components are incorporated
Compact cylinder unit: Just 1600mm in height
Compact hydro box: Only 600600mm footprint
Easy installation: Factory fitted pressure relief valve
Easy service: Relevant parts are located at the front of
the unit for easy maintenance
Easy transport: Handles attached on front and back
(cylinder unit)
Manometer
Expansion vessel*
Booster heater*
3-way valve
Booster heater*
Water pump
Tank
Plate heat
exchanger
Domestic
hot water pump
Manometer
Strainer
Scale trap
Strainer
Water pump
Plate heat
exchanger
Outdoor units
Adjustable feet
*Depending on model
PUHZ-SW160/200YKA
SHW230YKA2
Indoor units
Lighter weight
Compared to our previous model, the cylinder unit is up to 15kg lighter*.
This is thanks to the coil incorporated in the tank which has been removed and replaced by a much lighter plate heat exchanger.
*Comparison between EHST20C-VM2C and EHST20C-VM2B.
COP
(recharging)
140%
120%
100%
80%
60%
40%
20%
0%
<*1, *2>
10
12
14 year
Thanks to the L-shaped inlet pipe from the plate heat exchanger, stratification is well maintained after re-charge.
You do not need to worry about running out of hot water the same as with a conventional coil in tank.
Supply water temperature can be kept high until all the hot water in the tank has been used.
The secret behind our external plate heat exchanger system
Thanks to the unique plate heat exchanger and scale trap technology, a more efficient
performance is achieved. In conventional systems, there is a risk of calcium scale building
up on the heat-exchange plate if it is exposed to tap water directly. Therefore, it is difficult
to use plate-based heat exchangers to heat tap water. To resolve this problem, ECODAN
is equipped with a scale trap that catches homogeneous calcium nuclei in the tap water
before it has a chance to grow into large scales, thereby inhibiting build-up in the external
heat exchanger. ECODAN can use a plate heat exchanger to heat tap water, resulting in
much higher domestic hot water performance.
Circulating Water
Tap Water
Hot Water
Pump
Scale Trap
Notice: In the case of the special conditions such as very hard tap water, please consult with a specialist
before installation.
Fresh Water
P-HEX
External P-HEX circuit
148
Auto Adaptation
Maximize energy savings while retaining comfort at all times
60C
Flow temp.
If flow
temperature is
lowered 1C
COP is
improved 2%
30C
-15C
10C
Outdoor temp.
Mitsubishi Electrics Auto Adaptation function automatically tracks changes in the actual room temperature
and outdoor temperature and adjusts the flow temperature accordingly.
Aiming to realise further comfort and energy savings, Mitsubishi Electric is proud to introduce a revolutionary new controller. Our advanced Auto
Adaptation function measures the room temperature and outdoor temperature, and then calculates the required heating capacity for the room.
Simply stated, the flow temperature is automatically controlled according to the required heating capacity, while optimal room temperature is
maintained at all times, ensuring the appropriate heating capacity and preventing energy from being wasted. Furthermore, by estimating future
changes in room temperature, the system works to prevent unnecessary increases and decreases in the flow temperature.
Accordingly, Auto Adaptation maximises both comfort and energy savings without the need for complicated settings.
Future room temperature estimation
Room temp.
Target temp.
3 points
Future
T0 T1 Current
Time
Settings can be
performed using
an SD card.
Using ECODAN, it is possible to control two different flow temperatures, thereby managing two different heating load requirements. The system
can adjust and maintain two flow temperatures when different temperatures are required for different rooms; for example, controlling a flow
temperature of 40C for the bedroom radiators and another flow temperature of 30C for the living room floor heating.
Another feature of this model is that two-zone cooling control is now possible. Using these functions it is easy to maintain the most comfortable
temperature in each room and to save energy too.
Two temperature zones
40C
Hydro Box
Pump
FTC
Mixing control
Flow Switch
Radiator
Mixing
valve
Pump
Mixing tank
30C
Flow Switch
Underfloor heating
*Items such as mixing tank, mixing valve flow switch and pumps are not included and need to be purchased locally.
149
Settings can be
performed using
an SD card.
A maximum of 6 units* can be configured according to the heating/cooling load of the building. The most efficient number of operating units is
determined automatically based on heating/cooling load. This enables ECODAN to provide optimal room temperature control, and thus superior
comfort for room occupants. Also incorporated is a rotation function that enables each unit to run for an equal time period.
If one of the units malfunctions when using the Multiple Unit Control, another unit can be automatically operated for back-up, thereby preventing
the system operation from stopping completely.
*Only same models (same capacity) can be used.
1 unit
2 units
3 units
4 units
5 units
6 units
100
Inefficient operation
at low capacity.
ON/OFF control
Total Capacity
Up to
23kW
+
FTC
FTC
23kW
FTC
slave
master
23kW
FTC
slave
23kW
slave
23kW
FTC
FTC
slave
slave
138kW!!
23kW
FTC
slave
Settings can be
performed using
an SD card.
The flexibility of ECODANs intelligent control allows the system to be combined with the boiler currently in use. Additionally, this control can judge
which heating source to use either ECODAN or the existing boiler, based on various conditions*.
In the event of one heating unit not working due to some unforeseen problem, the other heating system can be used as a back-up, thereby
preventing the heating system operation from stopping completely.
*Please check below Heat source switchover.
Hydro box
Room temperature
wireless remote controller (option)
FTC
Electricity
Radiator
Radiator
Pump
Other source
(Gas, Oil, etc)
Mixing tank
Boiler
* Items such as a mixing tank, and pump are not included and need to be purchased locally.
150
Remote controllers
Smart user-friendly controller with stylish design
Main remote controller
Large screen and backlight for excellent visibility, even in dark environment
Multi-language support (supports 15 languages)
Can be removed from main unit and installed in a remote location (up to 500m)
Quick reading of operation data (7.5 times faster than previous model)
Wide range of convenient functions in response to user demand
Function settings
Floor drying mode
NEW Energy monitoring
Weekly timer
NEW Two-zone control (cooling and heating)
Holiday mode
NEW Two separate schedules
NEW Summer time setting
Legionella prevention
Error codes
Built-in room temperature sensors
Hybrid control (boiler interlock)
13 Jun 2015
13:41
PAR-WR51R-E (Option)
Receiver
Main controller
PAR-WT50R-E (Option)
Wireless remote controller
Settings can be
performed using
an SD card.
Energy monitoring
View electricity consumption and heat output on the remote controller
Other features
Daily, monthly and yearly data are stored and can be displayed using the main
remote controller.
External power meter and heat meter can be connected for accurate measurement.
SD card is also available for storing data.
Heating capacity
produced
Electric energy
used
*Using pre-set values on the main remote controller, estimated energy consumption/output can be shown without external power
and a heat meter.
Depending on operating condition and system configuration, there is some possibility to show different data from the reality.
*This function is available depending on the version of the outdoor unit model.
Settings can be
performed using
an SD card.
Just switch the summer time mode on using the main remote
controller and the clock in the main remote controller is adjusted to
summer time hours.
This function can release the end user from clock setting tasks.
Settings can be
performed using
an SD card.
29
2015
23:59
6kWh
6kWh
15kWh
15kWh
30
Summer time
2015
0:00
1 Sep 2015
Schedule timer
Schedule timer
Jan
1 Apr
2 Nov
12:30
Oct
Mar
Dec
Schedule 1
Winter time
Space heating
daytime
Domestic hot water early morning
Schedule 2
Summer time
151
Easy commissioning
Pump for primary water circuit* speed setting possible using ECODANs main remote controller
Even when the system is running, pump output can be set to one of five different settings using
the main remote controller.
The person commissioning the system can adjust this speed much more easily.
*Speed setting of pump for domestic hot water is not available through the main remote controller
when the system is running.
Settings can be
performed using
an SD card.
SD* card
For easier settings and data logging
The initial setting for ECODAN is now simpler than ever
before. The special software enables the required initial
settings to be saved to an SD card using a personal
computer. The system set-up is as easy as moving the SD
card from the computer to the SD card slot in the indoor
unit. Compared to the previous procedure of inputting
settings using the main controller at the installation site,
a remarkable reduction in set-up time has been achieved.
Thus, it is ideal for busy installers.
SD card slot
SD card
SD card
All items that are set by the main controller can be set via a personal
computer.
152
EHST20C- EHST20C- EHST20C- EHST20C- EHST20C- EHST20C- EHST20C- EHST20C- EHST20D- EHST20D- EHST20D- EHST20D- EHST20D- EHST20C- EHST20DVM2C
VM6C
YM9C
TM9C
VM2EC
VM6EC
YM9EC
MEC
VM2C
YM9C
VM2EC
MHC
MEC
MHCW*2 MHCW*2
Heating only
Type
Dimensions
Immersion heater
Expansion vessel
Booster heater
103
105
97
103
96
110
103
HWD
mm
kg
Weight (empty)
1600595680
110
111
112
112
104
105
106
Booster
heater
Immersion
heater
400/Three/50 230/Three/50
230/Single/50
230/Single/50
400/Three/50
Capacity
kW
6 (2/4/6)
9 (3/6/9)
9 (3/6/9)
6 (2/4/6)
9 (3/6/9)
9 (3/6/9)
Current
26
13
23
26
13
13
Breaker size
16
32
16
32
16
32
16
16
16
16
230/Single/50
230/Single/50
Capacity
kW
Current
13
13
16
16
Breaker size
Domestic
hot water tank
103
230/Single/50
Volume / Material
Guaranteed
operating
range*1
Ambient
Target
temperature
range
Heating
Cooling
Flow temperature
Outdoor
L/
C
Heating
Cooling
Room temperature
10~30
Flow temperature
25~60
Room temperature
DHW
40~60
Legionella prevention
60~70
dB (A)
28
<Hydro box>
Model name
EHSDMEC
EHSDMC
EHSDVM2C
EHSDYM9C
EHSCMEC
EHSCVM2C
EHSCVM2EC
Type
EHSCYM9EC
EHSCTM9C
EHSEMEC
EHSEYM9EC
Booster heater
38
43
44
45
42
48
49
44
49
44
49
60
62
mm
kg
800530360
950600360
43
230/Single/50
EHSCYM9C
Expansion vessel
Weight (empty)
Heater
EHSCVM6EC
Immersion heater
HWD
Dimensions
EHSCVM6C
Heating only
230/Three/50
400/Three/50
Capacity
kW
9 (3/6/9)
6 (2/4/6)
6 (2/4/6)
9 (3/6/9)
9 (3/6/9)
9 (3/6/9)
9 (3/6/9)
Current
13
26
26
13
13
23
13
Breaker size
16
16
16
16
32
32
16
16
32
16
Guaranteed
operating
range*1
Ambient
Target
temperature
range
230/Single/50 400/Three/50
230/Single/50
0~35*1
C
Heating
Cooling
Heating
Room temperature
10~30
Flow temperature
25~60
Cooling
Room temperature
Flow temperature
Outdoor
dB (A)
400/Three/50
28
30
Model name
Immersion heater
Expansion vessel
kg
103
Guaranteed
operating
range*1
Target
temperature
range
Dimensions
103
230/Single/50
230/Single/50
kW
Current
Breaker size
16
230/Single/50
400/Three/50
9 (3/6/9)
Current
13
16
Breaker size
16
16
16
L/
0~35*1
Heating
Cooling
Room temperature
10~30
Flow temperature
25~60
Room temperature
Flow temperature
5~25
40~60
60~70
dB (A)
28
DHW
Legionella prevention
Heater
Booster
heater
Guaranteed
operating
range*1
Ambient
Target
temperature
range
Heating
Outdoor
Cooling
0~35*1
C
Heating
Cooling
Room temperature
10~30
Flow temperature
25~60
Room temperature
Flow temperature
5~25
dB (A)
28
30
153
63
61
Cooling
49
230/Single/50
Heating
43
230/Single/50
kW
Outdoor
45
950600360
kW
Current
Ambient
kg
800530360
Capacity
Capacity
Volume / Material
mm
Capacity
HWD
Weight (empty)
230/Single/50
Breaker size
Domestic
hot water tank
110
96
Booster heater
1600595680
mm
Immersion
heater
ERSEYM9EC
ERSEMEC
HWD
Booster
heater
ERSCVM2C
ERSCMEC
Expansion vessel
Weight (empty)
Heater
ERSDVM2C
Type
Immersion heater
Booster heater
Dimensions
Model name
Type
Outdoor unit
Model name
SUHZPUHZPUHZPUHZPUHZPUHZPUHZSW45VA (H)*1 SW50VKA (-BS) SW75VHA (-BS) SW100V/YHA (-BS) SW120V/YHA (-BS) SW160YKA (-BS) SW200YKA (-BS)
Dimensions
HWD
mm
880840330
630809300
kg
54
43
75
118/130
Heating
(A2/W35)
Cooling
(A35/W7)
Cooling
(A35/W18)
136
118/130
VHA : 230/Single/50
Capacity
kW
COP
Power input
kW
Capacity
kW
PUHZSHW80VHA
PUHZSHW112V/YHA
PUHZSHW140YHA
PUHZSHW230YKA2
120
120/134
134
149
23.00
4.50
5.50
8.00
11.20
16.00
22.00
25.00
8.00
11.20
14.00
5.06
4.42
4.40
4.45
4.10
4.20
4.00
4.65
4.46
4.22
3.65
0.889
1.244
1.818
2.517
3.902
5.238
6.250
1.720
2.511
3.318
6.301
23.00
3.50
5.00
7.50
10.00
12.00
16.00
20.00
8.00
11.20
14.00
3.40/3.04
2.97
3.40
3.32
3.24
3.11
2.80
3.55
3.34
2.96
2.37
Power input
kW
1.029/1.151
1.684
2.206
3.009
3.704
5.145
7.143
2.254
3.353
4.730
9.705
Capacity
kW
4.00
4.50
6.60
9.10
12.50
16.00
20.00
7.10
10.00
12.50
20.00
2.73
2.76
2.82
2.75
2.32
2.76
2.25
3.31
2.83
2.17
2.22
Power input
kW
1.465
1.630
2.340
3.309
5.388
5.797
8.889
2.145
3.534
5.760
9.009
Capacity
kW
3.80
5.00
7.10
10.00
14.00
18.00
22.00
7.10
10.00
12.50
20.00
4.28
4.60
4.43
4.35
4.08
4.56
4.10
4.52
4.74
4.26
3.55
kW
0.888
1.087
1.603
2.299
3.431
3.947
5.366
1.571
2.110
2.934
5.634
52
46
51
54
54
62
62
51
52
52
59
COP
EER
EER
Power input
Sound pressure
level (SPL)
Heating
dB (A)
Sound power
level (PWL)
Heating
dB (A)
61
63
68
70
72
78
78
69
70
70
75
12.0
13.0
17.0
29.5/13.0
29.5/13.0
19.0
21.0
29.5
35.0/13.0
13.0
26.0
20
16
25
32/16
32/16
25
32
32
40/16
16
32
mm
6.35/12.7
6.35/12.7
9.52/15.88
9.52/15.88
9.52/15.88
9.52/25.4
12.7/25.4
9.52/15.88
9.52/15.88
9.52/15.88
12.7/25.4
30
40
40
75
75
80
80
75
75
75
80
30
30
30
30
30
30
30
30
30
30
30
Heating
15 to +24
15 to +21
20 to +21
20 to +21
20 to +21
20 to +21
20 to +21
28 to +21
28 to +21
28 to +21
25 to +21
DHW
15 to +35
15 to +35
20 to +35
20 to +35
20 to +35
20 to +35
20 to +35
28 to +35
28 to +35
28 to +35
25 to +35
Cooling*2
10 to +46
15 to +46
15 to +46
15 to +46
15 to +46
15 to +46
15 to +46
15 to +46
15 to +46
15 to +46
15 to +46
Breaker size
Piping
Guaranteed
operating
range
Diameter Liquid/Gas
Note: based on EN 14511 (Input to circulation pump is not included.) It may differ according to the system configuration.
*1 SUHZ-SW45VAH incorporates base heater.
*2 Optional air protection guide is required where ambient temperature is lower than 5C.
Optional parts
<Indoor unit>
Parts name
Model name
Wirelss remote
controller
PAR-WT50R-E
Wirelss receiver
PAR-WR51R-E
Thermistors
PAC-SE41TS-E
Specification
PAC-TH011-E
PAC-TH011TK-E
For boiler
(flow and return temp.)
1Ph 3kW
*1
PAC-TH011HT-E
Immersion heater PAC-I03V2-E
Joint pipe
Hydro box
ESD or ESC ESE
models
models
EHPT accessories
for UK
Cylinder unit
EHST20C- EHST20C- EHST20C- EHST20C- EHST20C- EHST20C- EHST20C- EHST20C- EHST20D- EHST20D- EHST20D- EHST20D- EHST20D- EHST20C- EHST20D- ERST
VM2C
VM6C
YM9C
TM9C
VM2EC VM6EC YM9EC
MEC
VM2C
YM9C
VM2EC
MEC
MHC
MHCW MHCW models
PAC-WK01UK-E
PAC-SG73RJ-E
Wi-Fi interface
PAC-WF010-E
PAC-DP01-E
For PUHZ-SW200YKA/
SHW230YKA2 (-BS)
9.5212.7
D665mm H270mm W595mm
N/W: 14.5kg
*1 PAC-DP01-E is necessary when you use ERST units. If you use ERST units without this parts, drain will be flowed from the base of units, in cooling mode.
<Outdoor unit>
Parts name
Model name
Eco
Inverter
Power Inverter
ZUBADAN
SUHZSW45VA (H)
PUHZPUHZPUHZPUHZPUHZPUHZSW50VKA (-BS) SW75VHA (-BS) SW100V/YHA (-BS) SW120V/YHA (-BS) SW160YKA (-BS) SW200YKA (-BS)
PAC-SE60RA-E
PAC-SE61RA-E
MAC-886SG-E
PAC-SJ07SG-E
PAC-SG59SG-E
PAC-SH96SG-E
PAC-SJ06AG-E
PAC-SH63AG-E
PAC-SH95AG-E
PAC-SG61DS-E
PAC-SJ08DS-E
PAC-SG63DP-E
PAC-SG64DP-E
PAC-SH97DP-E
PAC-SK52ST
Drain socket
Centralised drain pan
154
EHPT20X-VM2C
EHPT20X-VM6C
Type
Expansion vessel
Booster heater
100
98
mm
kg
1600595680
98
99
100
230/Single/50
Power supply (V / Phase / Hz)
400/Three/50
230/Three/50
Capacity
kW
6 (2/4/6)
9 (3/6/9)
9 (3/6/9)
Current
26
13
23
Breaker size
16
32
16
32
230/Single/50
Volume / Material
230/Single/50
13
16
L/
Ambient
Guaranteed
operating range*1
Outdoor
Target
temperature
range
C
C
Room temperature
10~30
Flow temperature
25~60
DHW
40~60
Legionella prevention
60~70
dB (A)
28
Heating
EHPT20X-MHCW*2
Immersion heater
Weight (empty)
Heater
EHPT20X-TM9C
Heating only
HWD
Dimensions
EHPT20X-YM9C
<Hydro box>
Model name
EHPX-VM2C
EHPX-VM6C
Type
Immersion heater
Expansion vessel
Booster heater
HWD
Dimensions
800530360
mm
kg
Weight (empty)
37
38
Booster
heater
230/Single/50
230/Single/50
400/Three/50
Capacity
kW
6 (2/4/6)
9 (3/6/9)
Current
26
13
Breaker size
16
32
16
Ambient
Guaranteed
operating range*1
Outdoor
Target temperature range
Heating
38
230/Single/50
EHPX-YM9C
Heating only
0~35*1
C
C
Room temperature
10~30
Flow temperature
25~60
dB (A)
28
Outdoor unit
Model name
Dimensions
HWD
PUHZ-W50VHA2 (-BS)
PUHZ-W85VHA2 (-BS)
PUHZ-W112VHA (-BS)
mm
740950330
943950330
13501020330
13501020330
13501020330
kg
64
79
133
148
134
148
230/Single/50
230/Single/50
230/Single/50
400/Three/50
230/Single/50
400/Three/50
5.00
9.00
11.20
11.20
14.00
14.00
4.50
4.18
4.47
4.42
4.25
4.25
Heating
(A2/W35)
Capacity
kW
COP
Power input
kW
1.111
2.153
2.506
2.534
3.294
3.294
Capacity
kW
5.00
8.50
11.20
11.20
14.00
14.00
3.50
3.17
3.34
3.11
3.11
3.11
kW
1.429
2.681
3.353
3.601
4.502
4.502
46
48
53
53
53
53
COP
Power input
Sound pressure
level (SPL)
Heating
dB (A)
Sound power
level (PWL)
Heating
dB (A)
61
66
69
67
67
67
13.0
23.0
29.5
13.0
35.0
13.0
16
25
32
16
40
16
Heating
15 to +21
20 to +21
20 to +21
25 to +21
25 to +21
25 to +21
DHW
15 to +35
20 to +35
20 to +35
25 to +35
25 to +35
25 to +35
Cooling*1
15 to +46
15 to +46
15 to +46
15 to +46
15 to +46
15 to +46
Note: based on EN 14511 (Input to circulation pump is included.) It may differ according to the system configuration.
*1 Optional air protection guide is required where ambient temperature is lower than 5C.
155
13501020330
Optional parts
<Indoor unit>
Parts name
Model name
Specification
Cylinder unit
Hydro box
EHPX-VM6C
EHPX-YM9C
PAR-WT50R-E
Wireless receiver
PAR-WR51R-E
Thermistors
PAC-SE41TS-E
PAC-TH011-E
PAC-TH011TK-E
PAC-TH011HT-E
For boiler
(flow and return temp.)
Immersion heater
PAC-I03V2-E
1Ph 3kW
PAC-WK01UK-E
Wi-Fi interface
PAC-WF010-E
<Outdoor unit>
Parts name
Model name
Power Inverter
PUHZW50VHA2(-BS)
PUHZW85VHA2(-BS)
ZUBADAN
PUHZPUHZPUHZPUHZW112VHA (-BS) HW112YHA2(-BS) HW140VHA2(-BS) HW140YHA2(-BS)
PAC-SE60RA-E
PAC-SG59SG-E
PAC-SH63AG-E
Drain socket
PAC-SG61DS-E
PAC-SG64DP-E
PAC-SK52ST
Model name
Description
PAC-IF011B-E
1 PC Board w/ Case
PAC-IF032B-E
1 PC Board w/ Case
System controllers
PAC-IF061B-E
1 PC Board w/ Case
PAC-IF062B-E
1 PC Board w/ Case
PAC-SIF051B-E
1 PC Board w/ Case
156
Combination table
Type
Package type
Model name
PUHZW50VHA2
Split type
Eco
Inverter
Power Inverter
ZUBADAN
PUHZW85VHA2
Power Inverter
PUHZSW50VKA
EHST20C-VM2C
EHST20C-VM6C
EHST20C-YM9C
EHST20C-TM9C
EHST20C-VM2EC
EHST20C-VM6EC
EHST20C-YM9EC
EHST20C-MEC
EHST20C-MHCW
Cylinder unit
EHST20D-VM2C
EHST20D-MEC
EHST20D-MHC
EHST20D-MHCW
EHST20D-VM2EC
EHST20D-YM9C
ERST20C-MEC
ERST20C-VM2C
ERST20D-MEC
ERST20D-VM2C
EHPT20X-VM2C
EHPT20X-VM6C
EHPT20X-YM9C
EHPT20X-TM9C
EHPT20X-MHCW
EHSC-VM2C
EHSC-VM2EC
EHSC-VM6C
EHSC-VM6EC
EHSC-YM9C
EHSC-YM9EC
EHSC-TM9C
EHSC-MEC
Hydro box
EHSD-VM2C
EHSD-YM9C
EHSD-MEC
EHSD-MC
ERSC-VM2C
ERSC-MEC
ERSD-VM2C
EHPX-VM2C
EHPX-VM6C
EHPX-YM9C
EHSE-YM9EC
EHSE-MEC
ERSE-YM9EC
ERSE-MEC
157
PUHZSW75VHA
Split type
Power Inverter
Mr. SLIM+
ZUBADAN
PUHZFRP71VHA
: Combination is available.
Mr.SLIM+
A smart air conditioning and hot water supply system conceived from
eco-conscious ideas
Mr. SLIM+ has a heat recovery function, which uses waste heat from air conditioners to heat water.
Thanks to heat recovery, Mr. SLIM+ model can achieve a COP of 7.0*, resulting in intelligent systems
with amazing efficiency.
*Conditions for air-to-air cooling: Indoor 27C (dry bulb) 19C (wet bulb); Outdoor 35C (dry bulb)
Various operations
Mr. SLIM / Air to Air (Air Cooling)
Air-to-Air cooling using Air-to-Air indoor unit
159
Specifications
Indoor unit
PLA-ZRP71BA
Outdoor unit
PKA-RP71KAL
PCA-RP71KA
Refrigerant
Power supply
Air-to-Air Cooling
(ATA)
Capacity
Rated
kW
7.1
7.1
7.1
7.1
7.1
7.1
7.1
Min-Max
kW
3.3-8.1
3.3-8.1
3.3-8.1
3.3-8.1
3.3-8.1
3.3-8.1
3.3-8.1
Rated
kW
1.85
1.88
1.90
2.26
1.97
2.10
2.08
3.84
3.78
3.74
3.14
3.60
3.38
3.41
kW
7.1
7.1
7.1
7.1
7.1
7.1
7.1
kWh/a
382
393
387
462
408
459
441
5.6
Design load
Annual electricity consumption *1
SEER *3
Energy-efficiency class
Capacity
Total input
6.3
6.4
5.4
6.1
5.4
A++
A++
A++
A+
kW
8.0
8.0
8.0
8.0
8.0
8.0
8.0
Min-Max
kW
3.5-10.2
3.5-10.2
3.5-10.2
3.5-10.2
3.5-10.2
3.5-10.2
3.5-10.2
Rated
kW
2.05
2.26
2.26
2.42
2.28
2.09
2.09
3.90
3.54
3.54
3.14
3.33
3.83
3.83
4.7
4.7
4.7
4.7
4.7
4.9
4.9
4.7 (10C)
4.7 (10C)
4.7 (10C)
4.7 (10C)
4.7 (10C)
4.9 (10C)
4.9 (10C)
at bivalent temperature
kW
4.7 (10C)
4.7 (10C)
4.7 (10C)
4.7 (10C)
4.7 (10C)
4.9 (10C)
4.9 (10C)
kW
3.5 (20C)
3.5 (20C)
3.5 (20C)
3.5 (20C)
3.5 (20C)
3.7 (20C)
3.7 (20C)
kW
kWh/a
1,510
1,569
1,555
1,787
1,709
1,799
1,799
4.4
4.2
4.2
3.7
3.9
3.8
3.8
A+
A+
A+
kW
Design load
Declared
capacity
6.5
A++
Rated
COP
L/min
22.90
kW
8.00
kW
1.96
4.08
COP
A2W35
Capacity
kW
7.50
Input
kW
2.65
2.83
COP
Heat
W45
recovery
(ATA
cooling &
ATW) *5
W55
kW
7.1+8.0
7.1+8.0
7.1+8.0
7.1+8.0
7.1+8.0
7.1+8.0
7.1+8.0
Input
kW
1.90
1.93
1.95
2.31
2.02
2.15
2.13
7.95
7.82
7.74
6.54
7.48
7.02
7.09
COP
Capacity (ATA cooling + ATW)
kW
7.1+9.0
7.1+9.0
7.1+9.0
6.4+9.0
7.1+9.0
7.1+9.0
7.1+9.0
Input
kW
2.97
3.00
3.02
3.25
3.09
3.22
3.20
5.42
5.37
5.33
4.74
5.21
5.00
5.03
COP
HxWxD
73
73
73
73
73
73
73
Cooling
m3/min
55
55
55
55
55
55
55
Heating
m3/min
55
55
55
55
55
55
55
dB(A)
47
47
47
47
47
47
47
level (SPL)
Heat recovery
dB(A)
47
47
47
47
47
47
47
ATA Heating
dB(A)
48
48
48
48
48
48
48
ATW Heating
dB(A)
48
48
48
48
48
48
48
Sound power
Cooling
dB(A)
67
67
67
67
67
67
67
level (PWL)
Heat recovery
dB(A)
67
67
67
67
67
67
67
ATA Heating
dB(A)
68
68
68
68
68
68
68
ATW Heating
dB(A)
68
68
68
68
68
68
68
19.0
19.0
19.0
19.0
19.0
19.0
19.0
Air volume
25
25
25
25
25
25
25
mm
9.52/15.88
9.52/15.88
9.52/15.88
9.52/15.88
9.52/15.88
9.52/15.88
9.52/15.88
20
20
20
20
20
20
20
Cooling *2
-15~+46
-15~+46
-15~+46
-15~+46
-15~+46
-15~+46
-15~+46
Heating
-20~+21
-20~+21
-20~+21
-20~+21
-20~+21
-20~+21
-20~+21
ATW
-20~+35
-20~+35
-20~+35
-20~+35
-20~+35
-20~+35
-20~+35
Heat recovery
+7~+46
+7~+46
+7~+46
+7~+46
+7~+46
+7~+46
+7~+46
Breaker size
Diameter
Liquid/Gas
Max. length
Out-In
Max. height
Out-In
*1
*2
*3
*4
*5
943-950-330 (+30)
mm
kg
Weight
Ext.piping
PEAD-RP71JAQ PEAD-RP71JALQ
R410A
Total input
Outdoor unit
PSA-RP71KA
230 / Single / 50
EER
Heating
(average
season)
PCA-RP71HA
Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
Optional air protection guide is required where ambient temperature is lower than 5C.
SEER/SCOP values are measured based on EN14825.
Air-to-Water values are measured based on EN14511 (Circulation pump input is not included.).
Conditions for Air-to-Air cooling: Indoor 27C (dry bulb) /19C (wet bulb); Outdoor 35C (dry bulb).
160
MELCloud
161
dB
dB
kW
dB
dB
A++
4.6
126
109
40
61
A++
5.0
170
109
40
61
ERST20D-****
A++
4.6
128
109
40
61
A++
5.0
174
109
40
61
EHSD-****
A++
4.6
126
40
61
A++
5.0
170
40
61
ERSD-****
A++
4.6
128
40
61
A++
5.0
174
40
61
EHST20D-****
A++
4.3
125
98
40
63
A++
4.5
163
98
40
63
ERST20D-****
A++
4.3
128
98
40
63
A++
4.5
167
98
40
63
EHSD-****
A++
4.3
125
40
63
A++
4.5
163
40
63
ERSD-****
A++
4.3
128
40
63
A++
4.5
167
40
63
EHST20C-****
A++
7.1
127
103
40
68
A++
7.2
165
103
40
68
ERST20C-****
A++
7.1
129
103
40
68
A++
7.2
167
103
40
68
EHSC-****
A++
7.1
127
40
68
A++
7.2
165
40
68
ERSC-****
A++
7.1
129
40
68
A++
7.2
167
40
68
EHST20C-****
A++
10.0
125
103
40
70
A++
10.4
164
103
40
70
ERST20C-****
A++
10.0
127
103
40
70
A++
10.4
166
103
40
70
EHSC-****
A++
10.0
125
40
70
A++
10.4
164
40
70
ERSC-****
A++
10.0
127
40
70
A++
10.4
166
40
70
EHST20C-****
A++
12.0
125
99
40
72
A++
12.9
162
99
40
72
ERST20C-****
A++
12.0
127
99
40
72
A++
12.9
164
99
40
72
EHSC-****
A++
12.0
125
40
72
A++
12.9
162
40
72
ERSC-****
A++
12.0
127
40
72
A++
12.9
164
40
72
EHSE-****
A++
13.5
125
45
78
A++
15.3
161
45
78
ERSE-****
A++
13.5
126
45
78
A++
15.3
163
45
78
EHSE-****
A++
15.5
128
45
78
A++
17.3
162
45
78
ERSE-****
A++
15.5
129
45
78
A++
17.3
164
45
78
EHST20C-****
A++
9.0
131
103
40
69
A++
9.6
171
103
40
69
ERST20C-****
A++
9.0
133
103
40
69
A++
9.6
174
103
40
69
EHSC-****
A++
9.0
131
40
69
A++
9.6
171
40
69
ERSC-****
A++
9.0
133
40
69
A++
9.6
174
40
69
EHST20C-****
A++
12.7
128
103
40
70
A++
13.9
167
103
40
70
ERST20C-****
A++
12.7
130
103
40
70
A++
13.9
169
103
40
70
EHSC-****
A++
12.7
128
40
70
A++
13.9
167
40
70
ERSC-****
A++
12.7
130
40
70
A++
13.9
169
40
70
EHST20C-****
A++
15.8
127
103
40
70
A++
17.0
164
103
40
70
ERST20C-****
A++
15.8
128
103
40
70
A++
17.0
165
103
40
70
EHSC-****
A++
15.8
127
40
70
A++
17.0
164
40
70
ERSC-****
A++
15.8
128
40
70
A++
17.0
165
40
70
EHSE-****
A++
23.0
127
45
75
A++
25.0
164
45
75
ERSE-****
A++
23.0
128
45
75
A++
25.0
165
45
75
EHPT20X-****
A++
5.0
127
99
40
61
A++
5.0
162
99
40
61
EHPX-****
A++
5.0
127
40
61
A++
5.0
162
40
61
EHPT20X-****
A++
8.5
128
97
40
66
A++
8.5
162
97
40
66
EHPX-****
A++
8.5
128
40
66
A++
8.5
162
40
66
EHPT20X-****
A++
10.0
125
100
40
67
A++
10.0
164
100
40
67
EHPX-****
A++
10.0
125
40
67
A++
10.0
164
40
67
EHPT20X-****
A++
12.7
126
100
40
67
A++
12.7
155
100
40
67
EHPX-****
A++
12.7
126
40
67
A++
12.7
155
40
67
EHPT20X-****
A++
15.8
126
96
40
67
A++
15.8
157
96
40
67
EHPX-****
A++
15.8
126
40
67
A++
15.8
157
40
67
EHST20C-****
A+
7.5
123
98
40
68
A++
7.5
163
98
40
68
EHSC-****
A+
7.5
123
40
68
A++
7.5
163
40
68
PUHZ-SW75VHA (-BS)
PUHZ-SW100VHA/YHA (-BS)
PUHZ-SW120VHA/YHA (-BS)
PUHZ-SW160YKA (-BS)
PUHZ-SW200YKA (-BS)
PUHZ-SHW80VHA (-BS)
PUHZ-SHW112VHA/YHA (-BS)
PUHZ-SHW140YHA (-BS)
PUHZ-SHW230YKA2
PUHZ-W50VHA2 (-BS)
PUHZ-W85VHA2 (-BS)
PUHZ-W112VHA (-BS)
PUHZ-HW112YHA2 (-BS)
PUHZ-HW140VHA2/YHA2 (-BS)
PUHZ-FRP71VHA
ATA & ATW hybrid system, Mr. SLIM+
EHST20D-****
kW
SUHZ-SW45VA
PUHZ-SW50VKA (-BS)
Indoor unit
Outdoor unit
162
SYSTEM
163
LOSSNAY LINE-UP
Application
Air volume
100
CMH
Model
150
CMH
250
CMH
350
CMH
500
CMH
650
CMH
800
CMH
1000
CMH
1500
CMH
2000
CMH
2500
CMH
LGH-RVX Series
Commerical
Use
LGH-RVXT Series NEW
VL-220CZGV-E NEW
Residential
Use
VL-100(E)U5-E
LGH-RVX SERIES
This commercially oriented system can be utilized virtually anywhere with high performance and functions.
LGH-RVXT SERIES
Thin large air volume models in LGH series with high performance and functions.
VL-220CZGV-E
Centralized ventilation for residential use with sensible heat exchange.
VL-100(E)U5-E
Wall mount model. Particularly suitable for houses and small offices.
REMOTE CONTROLLER
PZ-61DR-E
Function
(Communicating Mode)
Fanspeed selection
19
120
120
Night-purge (time)
PZ-61DR-E
LGH-RVX/RVXT VL-220CZGV-E
4 fan speeds
Energy recovery /
Bypass / Auto
Anytime schedule
15
Lower
case
120
No
No
No
No
No
No
No
No
No
No
No
No
Yes
Yes
Yes
Yes (available with
optional parts
P-133DUE-E)
No
Yes
Yes
No
No
Yes
Yes
Yes
Yes
Auto-Off timer
Yes
Yes
No
No
Weekly timer
Yes
No
No
Operation restrictions
(On/Off, ventilation mode,
fan speed)
Yes
Yes
Yes (ventilation
mode is available
with optional parts
P-133DUE-E)
No
No
No
Operation restrictions
(fan speed skip setting)
Screen contrast adjustment
Yes
Yes
No
Yes
Yes
No
No
Yes (8 languages)
Yes (8 languages)
No (English Only)
No (English Only)
Yes
Yes
No
No
Yes
Yes
Yes
Yes
Yes
No
No
No
Error indication
Yes
Yes
Yes
Yes
Error history
Yes
Yes
No
No
Language selection
Unit (mm)
2 of 4 fan speeds
Heat recovery /
Bypass / Auto (available
with optional parts
P-133DUE-E)
Unit (mm)
70
2 of 4 fan speeds
Energy recovery /
Bypass / Auto
Selecttable from 4
fan speeds
Yes
PZ-43SMF-E
4 fan speeds
Heat recovery /
Bypass / Auto (available
with optional parts
P-133DUE-E)
PZ-43SMF-E
LGH-RVX/RVXT VL-220CZGV-E
164
LOSSNAY
SYSTEM
Lossnay ventilation systems are renowned industry-wide for their efficiency. They
offer environment-friendly energy recovery and humidity control, and enable air
conditioning systems to simultaneously provide optimum room comfort and
energy savings.
Inside
In summer
In winter
Supply air
Supply air
LOSSNAY
Conventional
ventilator
28
33
13.3
20.1
56
63
Enthalpy (kJ/kg(DA))
62.1
84.6
7.5
3.1
10.6
29
100
LOSSNAY
Exhaust air
Room air
Dry bulb temperature
Air
conditioner
Absolute humidity
Relative humidity
Enthalpy
10.5g/kg'(DA)
Absolute humidity
50%
Relative humidity
52.9kJ/kg(DA)
5.2
1.9
46
50
Enthalpy (kJ/kg(DA))
29.2
4.7
8.2
3.1
11.3
28
100
Enthalpy
20.1g/kg'(DA)
63%
84.6kJ/kg(DA)
Exhaust air
Room air
33C
Indoor supply-air
Outdoor
Temp recovery
_ Indoor
_ Outdoor
temperature (C) = temperature (C)
temperature (C)
temperature (C) efficiency (%)
Calculation example: 28C = 33C _ (33C _ 26C) 72%
165
16
Outdoor air
26C
Conventional
ventilator
Absolute humidity
Relative humidity
Enthalpy
Outdoor air
20C
7.3g/kg'(DA)
Absolute humidity
50%
Relative humidity
38.5kJ/kg(DA)
Enthalpy
0C
1.9g/kg'(DA)
50%
4.7kJ/kg(DA)
Indoor supply-air
Indoor
_ Outdoor
=
Temp recovery + Outdoor
temperature (C)
temperature (C)
temperature (C)
temperature (C)
efficiency (%)
Calculation example: 16C = (20C _ 0C) 80% + 0C
Specifications / Dimensions
LGH-15/25RVX-E
LGH-15RVX-E
LGH-25RVX-E
220-240V/50Hz, 220V/60Hz
220-240V/50Hz, 220V/60Hz
Model
Electrical power supply
Ventilation mode
Bypass mode
Bypass mode
Fan speed
SP4
SP3
SP2
SP1
SP4
SP3
SP2
SP1
SP4
SP3
SP2
SP1
SP4
SP3
SP2
SP1
0.40
0.24
0.15
0.10
0.41
0.25
0.15
0.10
0.48
0.28
0.16
0.10
0.48
0.29
0.16
0.11
49
28
14
52
28
14
62
33
16
7.5
63
35
17
(m 3/h)
150
113
75
38
150
113
75
38
250
188
125
63
250
188
125
63
(L/s)
42
31
21
10
42
31
21
10
69
52
35
17
69
52
35
17
95
54
24
95
54
24
85
48
21
85
48
21
80.0
81.0
83.0
84.0
79.0
80.0
82.0
86.0
Heating
73.0
75.5
78.0
79.0
69.5
72.0
76.0
83.0
Cooling
(Measured at 1.5m under the center
of unit in an anechoeic chamber)
71.0
74.5
78.0
79.0
68.0
70.0
74.5
83.0
28.0
24.0
19.0
17.0
29.0
24.0
19.0
18.0
27.0
22.0
20.0
17.0
27.5
23.0
20.0
17.0
Air volume
External static pressure (Pa)
Temperature exchange efficiency (%)
Enthalpy exchange efficiency (%)
Noise (dB)
Weight (kg)
20
23
*The Air outlets noise (45 angle,1.5meters in front of the unit) is about 13dB (LGH-15RVX-E) / 15dB (LGH-25RVX-E) greater than the indicated value. (at Fan speed 4)
*The running current, the input power, the efficiency and the noise are based on the rating air volume, and 230V/50Hz.
*For the specification at the other frequency contact your dealer.
*Figures in the chart is measured according to Japan Industrial Standard (JIS B 8628). Characteristic Curves are measured by chamber method.
80
g)
cy (C
70
oolin
g)
SP4
5m 60
100
SP3
50
50
SP2
SP1
0
0
0
50
10
100
20
150
30
200
40
50
SA
(Supply air)
OA
(Outdoor air)
Maintenance space for
Lossnay core,
air filters,
fan,
high efficiency filter
40
3
300 (m /h)
250
60
Air volume
RA
(Return air)
EA
(Exhaust air)
70
80
119
Lossnay core
54
(L/s)
Enth
alpy
150
nge e
y ex
cha
fficien
nge
exch
ange
cy
effic
80
40m
ienc
y (H
efficie
ncy (
SP4
100
eatin
70
g)
Cooli
30m
ng)
20m
60
SP3
50
10m 50
SP2
SP1
0
0
0
100
10
20
30
200
40
50
60
Air volume
40
3
400 (m /h)
300
70
80
90
289
Air filters
Unit (mm)
100
110 (L/s)
102
65
RA
(Return air)
EA
(Exhaust air)
SA
(Supply air)
OA
(Outdoor air)
20
excha
halp
780
65
50
Control box
Maintenance cover
735
530
Ent
200
90
rature
Temp
e
Inspection
opening
450 x 450
or more
115
icien
150
10m
eatin
115
e eff
cy
y (H
658
ienc
20
effic
ang
fficien
782
ange
119
102
Lossnay core
64
Inspection
opening
450 x 450
or more
780
65
Control box
30
289
Maintenance cover
Power supply cable opening
High efficiency filter (sold separately) attachment position
64
Air filters
142
160
exch
exch
90
610
450
alpy
nge e
15m
150 to 250
Enth
20m
excha
alpy
rature
Enth
Temp
e
97.5
110
250
200
Unit (mm)
166
Specifications / Dimensions
LGH-35/50RVX-E
LGH-35RVX-E
LGH-50RVX-E
220-240V/50Hz, 220V/60Hz
220-240V/50Hz, 220V/60Hz
Model
Electrical power supply
Ventilation mode
Bypass mode
Bypass mode
Fan speed
SP4
SP3
SP2
SP1
SP4
SP3
SP2
SP1
SP4
SP3
SP2
SP1
SP4
SP3
SP2
SP1
0.98 0.54
0.26
0.12
0.98
0.56
0.28
0.13
1.15
0.59
0.26
0.13
1.15
0.59
0.27
0.13
Air volume
(L/s)
140
70
31
11
145
72
35
13
165
78
32
12
173
81
35
14
350
263
175
88
350
263
175
88
500
375
250
125
500
375
250
125
35
97
73
49
24
97
73
49
24
139
104
69
35
139
104
69
160
90
40
10
160
90
40
10
120
68
30
120
68
30
80.0 82.5
86.0
88.5
78.0
81.0
83.5
87.0
Heating
71.5 74.0
78.5
83.5
69.0
71.0
75.0
82.5
Cooling
(Measured at 1.5m under the center
of unit in an anechoeic chamber)
71.0 73.0
78.0
82.0
66.5
68.0
72.5
82.0
32.0 28.0
20.0
17.0
32.5
28.0
20.0
18.0
34.0
28.0
19.0
18.0
35.0
29.0
20.0
18.0
30
33
*The Air outlets noise (45 angle,1.5meters in front of the unit) is about 12dB (LGH-35RVX-E) / 18dB (LGH-50RVX-E) greater than the indicated value. (at Fan speed 4)
*The running current, the input power, the efficiency and the noise are based on the rating air volume, and 230V/50Hz.
*For the specification at the other frequency contact your dealer.
*Figures in the chart is measured according to Japan Industrial Standard (JIS B 8628). Characteristic Curves are measured by chamber method.
cy (H
icien
cy (
200
80
g)
70
Coo
eatin
20m
ling)
60
SP4
50
150
SP3
10m
100
SP2
50
30
SP1
0
0
0
100
20
40
200
40
300
60
80
400
100
500
120
Air volume
140
20
160
RA
(Return air)
EA
(Exhaust air)
OA
(Outdoor air)
SA
(Supply air)
(m3/h)
600
124
Lossnay core
64
180 (L/s)
888
exch
ang
fficien
effic
cy
e eff
ienc
y (H
icien
g)
60m
cy (
150
80
eatin
Coo
ling)
60
SP4
100
40m
50
SP3
20m
SP2
50
40
SP1
0
0
0
100
20
200
40
60
70
300
80
400
100
Air volume
120
500
140
30
3
700 (m /h)
600
160
180
(L/s)
RA
(Return air)
EA
(Exhaust air)
1063
alpy
200
nge e
ange
SA
(Supply air)
OA
(Outdoor air)
Maintenance space for
Lossnay core,
air filters,
fan,
high efficiency filter
124
Lossnay core
79
167
Unit (mm)
1016
745
Enth
exch
alpy
90
Enth
250
excha
Air filters
20
85
Air supply fan
55
Control box
331
Maintenance cover
Power supply cable opening
Inspection
opening
450 x 450
or more
300
85
115
e eff
cy
115
ang
fficien
icien
875
921
exch
nge e
e eff
124
20
ang
142
250
exch
90
Inspection
opening
450 x 450
or more
888
85
Air supply fan 30
Control box
331
Maintenance cover
Power supply cable opening
High efficiency filter (sold separately) attachment position
79
Air filters
192
alpy
30m
208
alpy
Enth
40m
excha
874
650
rature
300
Temp
e
Enth
350
160
Unit (mm)
LGH-65/80RVX-E
LGH-65RVX-E
LGH-80RVX-E
220-240V/50Hz, 220V/60Hz
220-240V/50Hz, 220V/60Hz
Model
Electrical power supply
Ventilation mode
Bypass mode
Bypass mode
Fan speed
SP4
SP3
SP2
SP1
SP4
SP3
SP2
SP1
SP4
SP3
SP2
SP1
SP4
SP3
SP2
SP1
1.65 0.90
0.39
0.15
1.72
0.86
0.38
0.16
1.82
0.83
0.36
0.15
1.97
0.86
0.40
0.15
252
131
49
15
262
131
47
17
335
151
60
18
340
151
64
20
(m 3/h)
650
488
325
163
650
488
325
163
800
600
400
200
800
600
400
200
(L/s)
181
135
90
45
181
135
90
45
222
167
111
56
222
167
111
56
120
68
30
120
68
30
150
85
38
10
150
85
38
10
77.0 81.0
84.0
86.0
79.0
82.5
84.0
85.0
Heating
68.5 71.0
76.0
82.0
71.0
73.5
78.0
81.0
Cooling
(Measured at 1.5m under the center
of unit in an anechoeic chamber)
66.0 69.5
74.0
81.0
70.0
72.5
78.0
81.0
34.5 29.0
22.0
18.0
35.5
29.0
22.0
18.0
34.5
30.0
23.0
18.0
36.0
30.0
23.0
18.0
38
48
*The Air outlets noise (45 angle,1.5meters in front of the unit) is about 16dB (LGH-65RVX-E) / 24dB (LGH-80RVX-E) greater than the indicated value. (at Fan speed 4)
*The running current, the input power, the efficiency and the noise are based on the rating air volume, and 230V/50Hz.
*For the specification at the other frequency contact your dealer.
*Use this unit with static pressure 240Pa or less at Fan speed 4. Otherwise the noise level might be large. (Only LGH-80RVX-E)
*Figures in the chart is measured according to Japan Industrial Standard (JIS B 8628). Characteristic Curves are measured by chamber method.
60
20m
40
SP2
30
SP1
100
20
200
40
60
300
400
500
600
700
800
20
3
1000 (m /h)
900
Air volume
SA
(Supply air)
OA
(Outdoor air)
124
Lossnay core
79
(L/s)
70
80m
SP4
60m
150
SP3
40m
100
50
0
0
0
SP2
50
400
100
60
50
40
30
SP1
200
165
80
100m
600
150
800
200
Air volume
1000
250
300
1200
350
20
(m3/h)
(L/s)
RA
(Return air)
EA
(Exhaust air)
SA
(Supply air)
OA
(Outdoor air)
Maintenance space for
Lossnay core,
air filters,
fan,
high efficiency filter
165
Inspection
opening
450 x 450
or more
Lossnay core
79
77
Air supply fan
Control box
40
Maintenance cover
404
Power supply cable opening
High efficiency filter (sold separately) attachment position
1144
79
242
200
Unit (mm)
1004
690
250
90
ncy
Entha
lpy ex
chang
e effic
Enth
iency
alpy
(Heati
exch
ng)
ange
effic
ienc
y (C
oolin
g)
300
Air filters
1051
change efficie
908
Inspection
opening
450 x 450
or more
Air filters
115
0
0
50
258
SP3
RA
(Return air)
EA
(Exhaust air)
1001
70
20
40m
150
50
895
80
SP4
100
124
20
200
954
692
250
90
300
60m
Tempe
rature
excha
Enth
nge eff
alpy
iciency
exch
ange
Enth
efficie
alpy
ncy (
exch
Heati
ang
ng)
e eff
icien
cy (
Coo
ling)
350
115
192
208
Unit (mm)
168
Specifications / Dimensions
LGH-100/150RVX-E
LGH-100RVX-E
LGH-150RVX-E
220-240V/50Hz, 220V/60Hz
220-240V/50Hz, 220V/60Hz
Model
Electrical power supply
Ventilation mode
Bypass mode
Bypass mode
Fan speed
SP4
SP3
SP2
SP1
SP4
SP3
SP2
SP1
SP4
SP3
SP2
SP1
SP4
SP3
SP2
SP1
2.50 1.20
0.50
0.17
2.50
1.20
0.51
0.19
3.71
1.75
0.70
0.29
3.85
1.78
0.78
0.30
420
(m 3/h)
Air volume
(L/s)
200
75
21
420
200
75
23
670
311
123
38
698
311
124
44
1000 750
500
250
1000
750
500
250
1500 1125
750
375
1500 1125
750
375
278
208
139
69
278
208
139
69
417
313
208
104
417
313
208
104
170
96
43
11
170
96
43
11
175
98
44
11
175
98
44
11
80.0 83.0
86.5
89.5
80.0
82.5
84.0
85.0
Heating
72.5 74.0
78.0
87.0
72.0
73.5
78.0
81.0
Cooling
(Measured at 1.5m under the center
of unit in an anechoeic chamber)
71.0 73.0
77.0
85.5
70.5
72.5
78.0
81.0
37.0 31.0
23.0
18.0
38.0
32.0
24.0
18.0
39.0
32.0
24.0
18.0
40.5
33.0
26.0
18.0
54
98
*The Air outlets noise (45 angle,1.5meters in front of the unit) is about 21dB (LGH-100RVX-E) / 22dB (LGH-150RVX-E) greater than the indicated value. (at Fan speed 4)
*The running current, the input power, the efficiency and the noise are based on the rating air volume, and 230V/50Hz.
*For the specification at the other frequency contact your dealer.
*Use this unit between static pressure 60Pa and 240Pa at Fan speed 4. Otherwise the motor protection may work and reduce its output or the noise level might be larger. (Only LGH-100RVX-E)
*Use this unit with static pressure 250Pa or less at Fan speed 4. Otherwise the noise level might be larger (Only LGH-150RVX-E)
*Figures in the chart is measured according to Japan Industrial Standard (JIS B 8628). Characteristic Curves are measured by chamber method.
60m
SP4
40m 50
150
SP3
40
100
SP2
50
30
SP1
0
0
500
50
100
20
1500 (m3/h)
150
1000
200
250
300
Air volume
350
400
(L/s)
SA
(Supply air)
OA
(Outdoor air)
Maintenance space for
Lossnay core,
air filters,
fan,
high efficiency filter
Inspection
opening
450 x 450
or more
165
Lossnay core
79
1144
ge e
eatin
fficie
200
ncy
(Co
70
g)
olin
60
g)
SP4
150
50
SP3
100
40
SP2
50
30
SP1
0
0
0
500
100
1000
200
300
1500
400
2000
500
Air volume
600
2500
700
20
3000 (m3/h)
800
(L/s)
EA
(Exhaust air)
OA
(Outdoor air)
Lossnay core
44
RA
(Return air)
404
808
1144
Air filters
169
40
SA
(Supply air)
Inspection
opening
450 x 450
or more
40
26
ncy (H
690
1045
efficie
270
han
690
ange
exc
80
1004
alpy
250
iciency
exch
270
Enth
alpy
Enth
300
90
exchange eff
700
40
Temperature
Unit (mm)
Air filters
350
77
60
RA
(Return air)
EA
(Exhaust air)
115
70
ling)
200
80
115
y (Coo
80m
258
fficienc
cy
g)
258
ange e
1278
fficien
eatin
20
250
nge e
ncy (H
242
y exch
excha
efficie
242
ange
165
917
exch
90
1231
Enthalp
100m
alpy
300
rature
150 to 250
Temp
e
Enth
350
258
Unit (mm)
LGH-200RVX-E
LGH-200RVX-E
Model
220-240V/50Hz, 220V/60Hz
Ventilation mode
Bypass mode
Fan speed
SP4
SP3
SP2
SP1
SP4
SP3
SP2
SP1
4.88
2.20
0.88
0.33
4.54
2.06
0.87
0.35
850
400
153
42
853
372
150
49
(m 3/h)
2000
1500
1000
500
2000
1500
1000
500
(L/s)
556
417
278
139
556
417
278
139
150
84
38
10
150
84
38
10
80.0
83.0
86.5
89.5
Heating
72.5
74.0
78.0
87.0
Cooling
(Measured at 1.5m under the center
of unit in an anechoeic chamber)
71.0
73.0
77.0
85.5
40.0
36.0
28.0
18.0
41.0
36.0
27.0
19.0
110
*The Air outlets noise (45 angle,1.5meters in front of the unit) is about 21dB greater than the indicated value. (at Fan speed 4)
*The running current, the input power, the efficiency and the noise are based on the rating air volume, and 230V/50Hz.
*For the specification at the other frequency contact your dealer.
*Use this unit between static pressure 50Pa and 220Pa at Fan speed 4. Otherwise the motor protection may work and reduce its output or the noise level might be large.
*Figures in the chart is measured according to Japan Industrial Standard (JIS B 8628). Characteristic Curves are measured by chamber method.
Dimensions
SP3
100
40
SP2
50
30
SP1
0
0
0
500
100
1000
200
300
1500
400
2000
500
Air volume
600
2500
700
20
3
3000 (m /h)
800
(L/s)
Lossnay core
44
40
917
1272
SA
(Supply air)
Inspection
opening
450 x 450
or more
26
50
150
OA
(Outdoor air)
404
808
1144
Air filters
242
SP4
258
60
200
242
70
ooling)
40
RA
(Return air)
258
(Heating)
efficienc
y (C
EA
(Exhaust air)
270
80
917
efficienc
y
iency
1231
exchange
e effic
270
Enthalpy
250
chang
exchange
Enthalpy
ture ex
700
40
300
90
Tempe
ra
350
115
Characteristic Curve
Unit (mm)
170
Specifications / Dimensions
LGH-150/200RVXT-E
LGH-150RVXT-E
LGH-200RVXT-E
220-240V/50Hz, 220V/60Hz
220-240V/50Hz, 220V/60Hz
Model
Electrical power supply
Ventilation mode
Bypass mode
Bypass mode
Fan speed
SP4
SP3
SP2
SP1
SP4
SP3
SP2
SP1
SP4
SP3
SP2
SP1
SP4
SP3
SP2
SP1
4.30 2.40
1.10
0.36
3.40
1.80
0.77
0.31
5.40 2.70
1.10
0.39
5.00
2.20
0.85
0.34
792
407
Air volume
176
48
625
334
134
37
1000 494
197
56
916
150
45
750
375
1500 1125
750
375
500
500
(L/s)
417
313
208
104
417
313
208
104
556
417
278
139
556
417
278
139
Supply
175
98
44
11
175
98
44
11
175
98
44
11
175
98
44
11
Return
100
56
25
100
56
25
100
56
25
100
56
25
80.0 80.5
81.0
81.5
80.0 81.0
82.5
84.0
Heating
70.0 71.0
73.0
75.0
72.5 73.5
77.0
83.0
Cooling
69.0 70.0
72.0
74.0
70.0 71.0
74.5
80.5
39.5 35.5
29.5
22.0
39.0
33.0
26.5
20.5
39.5 35.5
28.0
22.0
40.5
34.5
27.0
20.5
421
1500 1125
Noise (dB)
Weight (kg)
156
159
*The running current, the input power, the efficiency and the noise are based on the rating air volume, and 230V/50Hz.
*For the specification at the other frequency contact your dealer.
*Figures in the chart is measured according to Japan Industrial Standard (JIS B 8628). Characteristic Curves are measured by chamber method.
100
SP2
50
215 250
SP1
Flange
Lossnay cores
0
0
500
100
1000
200
1500
300
2000
400
500
Air volume
2500 (m3/h)
Control box
(L/s)
600
1450
Supply
Power
supply
cable
opening
250 132
424
500
242
258
When using
250 duct
RA air filters
OA air filters
100
SP2
215 250
SP1
1000
200
1500
400
Air volume
2000
600
2500
3000 (m3/h)
800
(L/s)
Control box
1450
RA air filters
OA air filters
171
58
Exhaust
SA
(Supply
air)
Pipe guide
Supply
116
EA
(Exhaust
air)
Flange
Lossnay cores
500
945.7
RA
(Return
air)
945.7
SP3
OA
(Outdoor
air)
1980
945.7 945.7
SP4
150
Flange
1500
115
60 250
750
Supply
Return
200
60
Flange
750 255
(Cooling)
250
0
0
70
90
ating)
nge efficiency
300
50
80
ge efficiency (He
Enthalpy excha
ency
Enthalpy exchan
350
90
400
Unit (mm)
SA
(Supply
air)
Pipe guide
Power
supply
cable
opening
250 132
424
500
287
227
560 440 560
150
RA
(Return
air)
90
SP3
EA
(Exhaust
air)
287
227
210
SP4
200
OA
(Outdoor
air)
58
Exhaust
210
Supply
Return
Flange
1500
116
250
60
60 250
(Cooling)
Flange
115
nge efficiency
70
945.7
ating)
945.7
Enthalpy excha
300
80
ge efficiency (He
1980
945.7 945.7
Enthalpy exchan
350
750
ency
400
90
750 255
450
242
258
When using
250 duct
Unit (mm)
LGH-250RVXT-E
LGH-250RVXT-E
Model
220-240V/50Hz, 220V/60Hz
Ventilation mode
Bypass mode
Fan speed
SP4
SP3
SP2
SP1
SP4
SP3
SP2
SP1
7.60
3.60
1.40
0.57
6.90
3.10
1.30
0.49
1446
687
244
82
1298
587
212
69
(m 3/h)
2500
1875
1250
625
2500
1875
1250
625
(L/s)
694
521
347
174
694
521
347
174
Supply
175
98
44
11
175
98
44
11
Return
100
56
25
100
56
25
77.0
79.0
80.5
82.5
Heating
68.0
71.5
74.0
79.0
Cooling
65.5
69.0
71.5
76.5
43.0
39.0
32.0
24.0
44.0
38.5
31.0
22.5
198
*The running current, the input power, the efficiency and the noise are based on the rating air volume, and 230V/50Hz.
*For the specification at the other frequency contact your dealer.
*Figures in the chart is measured according to Japan Industrial Standard (JIS B 8628). Characteristic Curves are measured by chamber method.
Dimensions
Supply
Return
200
SP4
150
SP3
100
50
SP2
215 250
SP1
0
0
0
60
1000
200
2000
400
600
Air volume
4000 (m3/h)
3000
800
1000
(L/s)
OA
(Outdoor
air)
RA
(Return
air)
EA
(Exhaust
air)
SA
(Supply
air)
Flange
Lossnay cores
Control box
1450
RA air filters
OA air filters
58
Exhaust
Pipe guide
Supply
Power
supply
cable
opening
250 132
424
500
287
227
560 440 560
250
g)
Flange
1500
210
(Coolin
60 250
116
iciency
Flange
300
nge eff
70
115
y excha
eating)
945.7
Enthalp
80
efficiency
(H
945.7
exchange
1980
945.7 945.7
350
ency
Enthalpy
750
400
750 255
90
90
450
Characteristic Curve
242
258
When using
250 duct
Unit (mm)
172
OA
2F
EA
bed room
bed room
RA
SA
bed room
down
bath room
1F
porch
dining room
up
living room
toilet
kitchen
Smart Ventilation
More comfortable!
Product Merits
Newly Developed Heat Exchanger
During ventilation, Lossnay recovers warmth in the winter and
keeps air cool in the summer.
Reducing heating and cooling loads with a maximum exchange
efficiency of 86%.
Energy Efficient
The highest energy saving
in its class. (8.5W minimum
input power)
Saves heating and cooling
costs by minimizing energy
loss occuring during ventilation.
Quiet
ngth
173
Model
220-240V/50Hz, 220V/60Hz
Ventilation mode
Fan speed
Fan speed 4
Fan speed 3
Fan speed 2
Fan speed 1
0.60
0.29
0.18
0.11
80
35
18.5
8.5
(m 3/h)
230
165
120
65
(L/s)
64
46
33
18
164
84
44
13
82.0
84.0
85.0
86.0
Noise (dB)
31.0
25.0
19.0
14.0
Weight (kg)
31
Dimensions
Fan Speed 4
200
15m
70
Fan Speed 3
100
60
Fan Speed 2
EA
(Exhaust air)
Duct connecting
flange (EA)
139
720
80
(L/s)
100
Auxiliary fixture
OA
(Outdoor air)
Duct connecting
flange (OA)
199
320
362
60
Air volume
151
98
40
50
3
400 (m /h)
300
124
20
200
146
100
RA1
(Return air)
Fan Speed 1
0
0
31
116
SA
(Supply air)
234
80
Duct connecting
flange (RA1)
80
iency
86
Drain outlet
295
ge effic
885
exchan
33
850
25m
229
300
174 119
Duct connecting
flange (SA)
271
rature
Tempe
143
90
20
35m
31
400
Characteristic Curve
Drain pan
Unit (mm)
Model
220V/50Hz
230V/50Hz
240V/50Hz
220V/60Hz
Fan speed
High
Low
High
Low
High
Low
High
Low
100
55
105
60
106
61
103
57
30
13
31
15
34
17
34
17
73
80
73
80
72
79
73
80
36.5
24
37
25
38
27
38
25
Noise (dB)
Weight (kg)
7.5
(Adjust
able)
75
200 (min)
(Adjust
able)
75
233min
350 (max)
267.5
292
530
554
620
22
360min from nearest obstruction
: VL-100U5-E
: VL-100EU5-E
360min
12
Front panel
(Closed position)
Outer dia
752
Outer dia
792
Front panel
(Open position)
90
140
17
22
175
226
620
Shutter knob
(Closed position)
Shutter knob
(Open position)
150
252
183min
from nearest
obstruction
13.5
265
238.5
Pitch 20x10=200
119
95
108
97
87
25
Mounting holes
36 6
25
420
Mounting plate
40
(Adjustable)
Require to be secured
15
Require to be secured
Edge of main unit
95.5
Dimensions
200
54 Wall thickness
50 to 550
106
Unit (mm)
174