Sie sind auf Seite 1von 19

XYZ, LOCATION

Site Survey Report

Working towards a sustainable future

Google Image: Site Location Top View

Client Details:
Country

India

City

XYZ, Maharashtra

Contact Person

Mr. ABC

E-Mail ID

abc@xyz.com

Industry

---

Company

---

Purpose

Green Building Initiative

Site & Meteo Details:


Location Coordinates

xx.6348 N, xx.91369 E

Height from Sea Level

xxxx ft

Daily Solar Irradiation- Horizontal

xx.xx KWh/ m2

Ambient Temperature above 10 m


of Surface

xx.xx C

Wind Speed at 50 m Above sea


Level

xx.xx m/s

Project Details:
Type of Installation

Roof Top Installation (Seam Roof)

Estimated Array Peak Power

250 kWp

Shading Consideration

No Shading Effect

Grid Voltage

415 V

Phase Connection

3-Phase

Grid Frequency

50 Hz

Available Area

3000 sq. m.

Effective Area

2500 sq. m.

Sanctioned Load

342 kW

Earthing Arrangement

Not Available

Site Layout Plan:

0.5 m
Height

25 m

0.5 m
Height

0.5 m
Height
25 m

60 m

Metal Roof Profile


Thickness of the sheet: 0.4 mm

32 mm

90 mm

160 mm
250 mm

Roof Details:
Effective Roof Area : 2500 m2

Roof type : Seam roof


The slope of the roof on South - North side.
The tilt of the roof is 7-8 degree.
No ladder installed to access the roof at present.
Some punctures are there on the roof.
Water tank on South Side and tower on that water tank create shadow.16

Array Layout: Proposed Roof

S
N

North Slope

Equipment's Placement: Existing & Proposed


Equipment
Transformer
Electrical Room
DG

Inverter,
ACDB
Location
SMCB
Locations
Earth Pit
Locations

10

Shading Obstructions

Water Tank and


Tower over
Water tank as
Shading
Obstructions

11

Picture Descriptions:
S

25 m

Transformer

7
8

Electrical
Panel Room

3 4
1 2

25 m

DG

60 m

12

Pictures Description:

Picture 1: Picture taken from centre of the roof


towards S-W

Picture 2: Picture taken from centre of the roof


towards South

13

Pictures Description:

Picture 3:Picture taken from centre of roof


towards South-East

Picture 4: Picture taken from centre of the


roof towards East

14

Pictures Description:

Picture 5: Picture taken from centre of the roof


towards S-E

Picture 6 :Picture taken from centre of the


roof towards East

15

Pictures Description:

Picture 7: Picture taken from centre of the roof


towards North

Picture 8: Electrical Room( Picture taken from


roof)

16

Pictures Description:

Picture 9: Current Inverter, ACDB Location


Indoor

Picture 10: MCCB Breaker for Grid

17

Pictures Description:

Picture 11: Interconnection of DG and Grid

Picture 12: Tapping point for Solar

18

Contact Us
APSUN Power Private Limited
#506, Supreme Headquarters,
Near Pashankar Auto,
Mumbai Pune Bypass Highway,
Baner, Pune 411045

Working towards a sustainable future

T: +91-98960844445
E: rooplal.teli@apsun-power.com
W: www.apsun-power.com