Beruflich Dokumente
Kultur Dokumente
FLOW SWITCHES
z BELLOWS
z
MODEL BM
SWITZER style BM / BGM / GABM / GK-BM flow switches
are versatile instruments designed to accept different
paddle sizes to handle any line size. Materials of
construction and glandless design render the switches
compatible with most of the corrosive and toxic fluids. The
easy-to-fix design reduces installation costs and time.
Simple mechanical parts ensure high reliability and nearzero failures.
The microswitch of the instrument is operated by the
deflection of the paddle assembly due to velocity of flowing
MODEL GK-BM
fluid against the restraining force of the range spring through
a bellows sealed lever at a pre-determined flow rate.
SWITZER style AM / AGM flow switch is similar in design to
style BM but without bellows seal. It senses air flow or no
flow responding only to the velocity of air movement in a
duct. Provides a positive signal to detect change or loss of
air flow velocity caused by a closed damper, a loose fan
wheel, a slipped or broken fan belt, a dirty or clogged filter
or even an overload to a fan motor. Large paddles are used
for reliable switching.
GENERAL SPECIFICATION
Enclosure
BM & AM
BGM & AGM
Pressure Loss
Process Connection
AM Version
BM Threaded
Line size upto 1"
Line size above 1"
BM Flanged
From 40mm
Electrical Connection
BM & AM
ORDERING MATRIX
BASIC MODEL NO.
Weatherproof switches for circular pipes with ABS plastic
enclosure and threaded/ flanged / integral tee connection BM
Weatherproof switches for circular pipes with pressure die cast Al.
enclosure and threaded/ flanged / integral teeconnection BGM
Weatherproof switches for circular pipes with Investment casting
304 SS enclosure and threaded/ flanged / integral tee connection GABM4
Weatherproof switches for circular pipes with Investment casting
316 SS enclosure and threaded/ flanged / integral tee connection GABM6
Flameproof switches for circular pipes with die cast Al.
enclosure and threaded/ flanged / integral teeconnection GK-BM
Non-weatherproof switches for square / rectangular ducts with
ABS plastic enclosure andMS fixingplate AM
Weatherproof switches for square / rectangular ducts with
Pressure Die cast enclosure andMS fixing plate AGM
LINE SIZE (Refer Table3 & 4)
For Duct (Model AM& AGMonly) 000
For other models specify nominal line size in "mm"
[Eg. 015 for 15 mm NB (or 150 for 150 mm NB)] 015
Standard line sizes are 15,20,25,32,40,50,65,80,100,125,150,200,250 & 300 NB
RANGE CODE
Refer Table3
SWITCH ACTUATION
Raising R
Falling F
WETTED PARTS
Brass body, MS fixing plate & 316SS paddle (for model AM& AGM) 1
Brass body, Ph. Bronze bellows &316 SS paddle (for all except AM& AGM) 1
304 SS body,316L SS bellows & 316 SS paddle(for all except AM& AGM) 4
316 SS body, 316L SS bellows & 316SS paddle (for all exceptAM & AGM) 2
316 SS body, 316L SS bellows & 316
SS paddle(for all exceptAM & AGM) to NACE MR-01-75 N
PROCESS CONNECTION
Fixing plate (Model AM& AGMonly) PP
Integral Tee, BSPF Threads(upto 1" linesize) SL
Integral Tee, NPTF threads (upto 1"line size) SM
Threaded to 1" BSPM TH
Threaded to 1" NPTM TN
Flanged to 1" ANSI 150RF forline size 40 mmand above FA
Flanged to 2" ANSI 150RF for linesize 40 mm and above FB
Flanged to 1" ANSI 300RF forline size 40 mmand above FC
Flanged to 2" ANSI 300RF for linesize 40 mm and above FD
ADD 'M' for MS, '4' for 304 SS, ' 6' for 316 SS Integral tee / Flange
eg: SLM for MS Integral Tee with 1" BSPF Thread & SMM - for MS Integral Tee with 1" NPTF Thread
SL4 for 304 SS Integral Tee with 1" BSPF Thread & SM4 - for 304 Integral Tee with 1" NPTF Thread
FAM for MS Flange, FA4 for 304 SS Flange, FA6 for 316 SS Flange etc. for respective flanges
SWITCH CODE AND RATING
Refer Table1
ELECTRICAL ENTRY CODE
Refer Table2
DC RATING IN AMPS
AC
RATING
RESISTIVE
INDUCTIVE
15A
0.2
250 / 125V
0.4
AM, AGM,
BM, BGM,
GABM4,
GABM6 &
GK-BM
AM, AGM,
BM, BGM,
GABM4,
GABM6 &
GK-BM
BM, BGM
GABM4,
GABM6 &
GK-BM
BM, BGM
GABM4,
GABM6 &
GK-BM
( Note 4)
Si n g l e En t r y
Si z e
3/4" ETF
D u al E n t r y
B GM/AGM
GAB M4/
GAB M6
GK BM
BM /
AM
B GM/AGM
GAB M4/
GAB M6
GK BM
---
---
---
1/2" NPTF
---
3/4" NPTF
---
---
---
M20 1.5
.
---
M16 1.5
M16 Nylon Elbow
Cable Gland
---
---
---
---
---
---
---
T h r o u g h C o n n ec t o r
3 pin plug
---
---
---
---
7 pin plug
---
---
---
---
9 pin plug
---
---
---
---
Table3
Table4
SWITCHING RANGE-L PM
L INE
ON RISING FL OW
RANGE ON FAL L ING FL OW
SIZE
C o d e ' F'
Co d e ' R'
CODE
NB m m
MIN.
MAX.
MIN.
MAX.
MAX
FL OW
(L PM
WATER)
A DJ .RA NGE
INC.FL OW AT
VEL OCITY
Mt r /Sec .
A DJ .RA NGE
DEC.FL OW AT
VEL OCITY
Mt r /Sec .
Co d e R
Co d e F
175 x 80
2.0 to 5.0
1.0 to 4.0
175 x 54
3.5 to 9.0
2.5 to 8.0
PA DDL E
SIZE
mm
15
12
21
20
11
14
38
25
10
30
16
33
60
32
13
50
23
52
100
40
16
60
30
70
150
50
36
90
60
95
250
65
45
120
85
135
400
80
65
175
120
200
600
190
460
290
500
1000
100
280
190
310
1000
HR
380
890
530
930
1500
FM
150
420
300
470
1500
600
1360
800
1400
2000
HM
200
510
400
600
2000
PM
1210
2760
1580
2900
3700
650
1510
1020
1700
3700
1970
3830
2600
4200
6000
1240
2410
1850
2800
2600
4830
3500
2000
3080
2800
100
125
150
200
250
300
Max . r ec o m m en d ed f l o w v el o c i t y -- 10 Mt r /Sec
CMG :
CMS :
Sprinkler application
6000
UZ
5300
8500
HRM
3600
8500
NOTES
1.
Gr.IIA, IIB & IIC of IS/IEC:60079-1is equivalent to NEC CL.1, Gr.A, B, C & D.
2.
The maximum line pressure is the limiting value for flanged versions irrespective of the flange ratings. The flange is not
ntegral,
i
but screwed on to the body with a lock nut. Flange mounting is not available upto 32 mm.
3.
Accuracy & Repeatability are one and the same for all blind switches. Settings will slightly shift with varying temperature.
4.
Instruments can be supplied with hermetically sealed microswitches other than Code D general purpose microswitch. On-off
differentials will be different. Consult factory.
5.
All the ranges are in LPM water. For calculating equivalent airflow in NM/Hr. consult factory. For any liquid other thanwater,
the setting range depends on the specific gravity of the fluid at flow conditions. To get equivalent ranges for such liquids, a
specific gravity correction factor has to be applied. Consult factory.
6.
Maximum flow setting range is referred to as FSR herein. The maximum flow value mentioned in the table 3 is based on a
nominal flow velocity of 2.0 metre/second. The instrument can handle higher flow if the process flow velocity is more than
2.0 metre/second. For special ranges, consult factory.
7.
DPDT action is achieved by two SPDT switches synchronized to practical limits i.e., 2% of FSR. ON-OFF differentials of DPDT
contacts are 1.5 times than that of SPDT as force required to actuate the contacts are more.
8.
MWP : The value mentioned herein is the highest permissible pressure that can be applied. Cannot be proof tested for
any higher pressure value.
9.
Contact life of microswitches are 5 105 switching cycles for nominal load. To quench DC sparks, use a diode in parallel with
inductance, ensuring polarity. A RC network is also recommended with R value in Ohms equal to coil resistance and
C value in micro Farads equal to holding current in Amps.
10. Different lengths of paddles are used for different line sizes and ranges. Refer Instruction Manual for details.
11. Accuracy figures are exclusive of test equipment tolerance on the claimed values.
12. All performance data are guaranteed to 5 %.
MOUNTING DIMENSIONS
BM SCREWED
BM FLANGED
GABM SCREWED
GABM FLANGED
BGM SCREWED
BGM FLANGED
GKBM SCREWED
GKBM FLANGED
AM
www.switzerprocess.co.in
Bangalore
Mumbai
Chennai
New Delhi
Hyderabad
Pune
Kolkata
Phone : 03324659108
Fax : 03324659109
e-mail : kolkatabr@switzerinstrument.com
Vadodara
# AM / BM SeriesRev.3 (1113)