Sie sind auf Seite 1von 11

*&---------------------------------------------------------------------*

*& Report ZBIR_INST_EMP_FACT_UPDATE


*&
*&---------------------------------------------------------------------*
*----------------------------------------------------------------------*
* Author
: ANIL REDDY BOKKA
* Creation Date
: 25-AUG-2014
* Transaction
: ZBIR_FACT_UPDATE
* Technical design: <Technical design document name>
* Description
: <Short description of the functionality of the
*
program>
*----------------------------------------------------------------------*
* Modification Information
*----------------------------------------------------------------------*
* Date
: <DD-MMM-YYYY>
* Author
: <Name of the programmer/Programmer user ID>
* Change request : <Change request number>
* Transport number: <Transport number>
* Description
: <Short description of changes>
*----------------------------------------------------------------------*

REPORT zbir_inst_emp_fact_update NO STANDARD PAGE HEADING.


*&---------------------------------------------------------------------*
* Types Declaration
*&---------------------------------------------------------------------*
TYPES: BEGIN OF ty_udata,
anlage TYPE anlage,
operand TYPE e_operand,
ab
TYPE char10,
bis
TYPE char10,
value
TYPE char20,
END OF ty_udata.
TYPES: BEGIN OF ty_te221,
operand TYPE e_operand,
optyp
TYPE e_optyp,
END OF ty_te221.
TYPES: BEGIN OF ty_elog,
anlage TYPE anlage,
operand TYPE e_operand,
value
TYPE char20,
remark TYPE string,
END OF ty_elog.

DATA: it_udata TYPE TABLE OF ty_udata,


*
it_udata TYPE TABLE OF ty_udata,
it_elog TYPE TABLE OF ty_elog,
it_ettifn_new TYPE TABLE OF ettifn,
it_ettifn_old TYPE TABLE OF ettifn.
DATA: it_te221 TYPE TABLE OF ty_te221,
wa_te221 TYPE ty_te221.

DATA: wa_udata TYPE ty_udata,


wa_elog TYPE ty_elog,
wa_ettifn_new TYPE ettifn,
wa_ettifn_old TYPE ettifn.

DATA: lv_ab TYPE dats,


lv_bis TYPE dats.
*&---------------------------------------------------------------------*
* Selection Screen
*&---------------------------------------------------------------------*
SELECTION-SCREEN BEGIN OF BLOCK blk1 WITH FRAME TITLE text-001.
PARAMETERS: p_r1 RADIOBUTTON GROUP auto USER-COMMAND flag ,
p_r2 RADIOBUTTON GROUP auto DEFAULT 'X'.
SELECTION-SCREEN SKIP.
PARAMETERS p_file LIKE rlgrap-filename MEMORY ID tpc1 MODIF ID mod.
*SELECT-OPTIONS s_date FOR sy-datum NO-DISPLAY. "MEMORY ID tpc1 MODIF ID m
od OBLIGATORY.
SELECTION-SCREEN END OF BLOCK blk1.

*&---------------------------------------------------------------------*
* At Selection Screen
*&---------------------------------------------------------------------*
AT SELECTION-SCREEN OUTPUT.
LOOP AT SCREEN .
IF p_r1 = 'X' AND
screen-active =
ENDIF.
IF p_r2 = 'X' AND
screen-active =
ENDIF.
MODIFY SCREEN.
ENDLOOP.

screen-group1 = 'MOD'.
'1'.
screen-group1 = 'MOD'.
'0'.

AT SELECTION-SCREEN ON VALUE-REQUEST FOR p_file.


* Perform to upload the file.
PERFORM file_f4 USING p_file.
INCLUDE zbir_inst_emp_fact_update_ff01.

*&---------------------------------------------------------------------*
* Start Of Selection
*&---------------------------------------------------------------------*
START-OF-SELECTION.
IF p_r2 IS NOT INITIAL.
* Perform To Download Sample Data to Upload facts.
PERFORM download_sample_data.
ENDIF.
IF p_r1 IS NOT INITIAL.

PERFORM upload_data.
PERFORM insert_ettifn_table.
IF it_elog IS NOT INITIAL.
PERFORM display_error_log.
ENDIF.
ENDIF.

*----------------------------------------------------------------------*
***INCLUDE ZBIR_INST_EMP_FACT_UPDATE_FF01.
*----------------------------------------------------------------------*
*&---------------------------------------------------------------------*
*&
Form FILE_F4
*&---------------------------------------------------------------------*
*
Providing F4 Help to Upload The File
*----------------------------------------------------------------------*
FORM file_f4 USING
p_p_file.
DATA: lv_subrc LIKE sy-subrc,
lt_it_tab TYPE filetable.
CONSTANTS: lc_window_title
TYPE string VALUE 'Select Source Excel Fil
e',
lc_default_filename TYPE string VALUE '*.xls'.
* Display File Open Dialog control/screen
CALL METHOD cl_gui_frontend_services=>file_open_dialog
EXPORTING
window_title
= lc_window_title
default_filename = lc_default_filename
multiselection
= ' '
CHANGING
file_table
= lt_it_tab
rc
= lv_subrc.
* Write path on input parameter
LOOP AT lt_it_tab INTO p_p_file.
ENDLOOP.
ENDFORM.
" FILE_F4
*&---------------------------------------------------------------------*
*&
Form DOWNLOAD_SAMPLE_DATA
*&---------------------------------------------------------------------*
*
text
*----------------------------------------------------------------------*
* --> p1
text
* <-- p2
text
*----------------------------------------------------------------------*
FORM download_sample_data .
TYPES: BEGIN OF t_raw,
anlage TYPE anlage ,
operand TYPE e_operand,

ab
bis
value
text
END
OF

TYPE char10,
TYPE char10,
TYPE char12,
TYPE char50,
t_raw.

DATA: it_excel TYPE TABLE OF t_raw,


wa_excel TYPE t_raw.
DATA: lt_fieldname TYPE STANDARD TABLE OF cats_fieldname,
wa_fieldname TYPE cats_fieldname.
DATA: file_n TYPE string,
file_p TYPE string,
full_p TYPE string.
CONSTANTS: lc_window_title
lc_default_extension
lc_default_file_name
ate_format',
lc_initial_directory
lc_x
lc_filetype
lc_header

TYPE string
TYPE string
TYPE string

VALUE 'Select File path',


VALUE 'xls',
VALUE 'Installation_fact_upd

TYPE
TYPE
TYPE
TYPE

VALUE
VALUE
VALUE
VALUE

string
c
char10
xstring

'C:\',
'X',
'DAT',
'00'.

wa_fieldname-fieldname = text-t01.
APPEND wa_fieldname TO lt_fieldname.
CLEAR wa_fieldname.
wa_fieldname-fieldname = text-t02.
APPEND wa_fieldname TO lt_fieldname.
CLEAR wa_fieldname.
wa_fieldname-fieldname = text-t04.
APPEND wa_fieldname TO lt_fieldname.
CLEAR wa_fieldname.
wa_fieldname-fieldname = text-t05.
APPEND wa_fieldname TO lt_fieldname.
CLEAR wa_fieldname.
wa_fieldname-fieldname = text-t03.
APPEND wa_fieldname TO lt_fieldname.
CLEAR wa_fieldname.
wa_excel-anlage =
wa_excel-operand =
wa_excel-ab
=
wa_excel-bis
=
wa_excel-value
=
wa_excel-text
=
APPEND wa_excel TO
CLEAR wa_excel.

'3000001846'. " Sample Value


'F_EMPLOYEE'.
'01.01.2014'.
'31.01.2014'.
'X'.
'Value should be updated as X or Blank'.
it_excel.

wa_excel-anlage = '3000001846'.
wa_excel-operand = 'QUARTER_NO'.
wa_excel-value
= 'Z/WING-321'.

" Sample Value

wa_excel-ab
=
wa_excel-bis
=
wa_excel-text
=
APPEND wa_excel TO
CLEAR wa_excel.

'01.01.2014'.
'31.01.2014'.
'Value should be updated with Char10'.
it_excel.

wa_excel-anlage =
wa_excel-operand =
wa_excel-value
=
wa_excel-ab
=
wa_excel-bis
=
wa_excel-text
=
APPEND wa_excel TO
CLEAR wa_excel.

'3000001846'. " Sample Value


'EMPLOYE_NO'.
'202121'.
'01.01.2014'.
'31.01.2014'.
'Value should be updated with Char10'.
it_excel.

wa_excel-anlage =
wa_excel-operand =
wa_excel-value
=
wa_excel-ab
=
wa_excel-bis
=
wa_excel-text
=
APPEND wa_excel TO
CLEAR wa_excel.

'3000001846'. " Sample Value


'KWH_T'.
'500'.
'01.01.2014'.
'31.01.2014'.
'This value should be updated with DEC16'.
it_excel.

wa_excel-anlage =
wa_excel-operand =
wa_excel-value
=
wa_excel-ab
=
wa_excel-bis
=
wa_excel-text
=
APPEND wa_excel TO
CLEAR wa_excel.

'3000001846'. " Sample Value


'WP_LT'.
'WP_LT2CCOM'.
'01.01.2014'.
'31.01.2014'.
'This value should be updated in Fact Group'.
it_excel.

CALL METHOD cl_gui_frontend_services=>file_save_dialog


EXPORTING
window_title
= lc_window_title
default_extension
= lc_default_extension
default_file_name
= lc_default_file_name
initial_directory
= lc_initial_directory
prompt_on_overwrite = lc_x
CHANGING
filename
= file_n
path
= file_p
fullpath
= full_p
EXCEPTIONS
cntl_error
= 1
error_no_gui
= 2
not_supported_by_gui = 3
OTHERS
= 4.
IF full_p IS NOT INITIAL.
CALL FUNCTION 'GUI_DOWNLOAD'
EXPORTING
filename
= full_p
filetype
= lc_filetype
write_field_separator = lc_x
header
= lc_header

TABLES
data_tab
= it_excel
fieldnames
= lt_fieldname.
ENDIF.
ENDFORM.
" DOWNLOAD_SAMPLE_DATA
*&---------------------------------------------------------------------*
*&
Form UPLOAD_DATA
*&---------------------------------------------------------------------*
*
Upload Data From Flat File (XL Sheet)
*----------------------------------------------------------------------*
FORM upload_data .
IF p_file IS NOT INITIAL.
* Uploading Data from XLS file to Internal Table
CALL FUNCTION 'UPLOAD_XLS_FILE_2_ITAB'
EXPORTING
i_filename = p_file
TABLES
e_itab
= it_udata
EXCEPTIONS
file_error = 1
OTHERS
= 2.
IF sy-subrc <> 0.
*
MESSAGE ''006.'
ENDIF.

DELETE it_udata INDEX 1.


ENDIF.
ENDFORM.
" UPLOAD_DATA
*&---------------------------------------------------------------------*
*&
Form PREPARE_NEW_DATA
*&---------------------------------------------------------------------*
*
text
*----------------------------------------------------------------------*
* --> p1
text
* <-- p2
text
*----------------------------------------------------------------------*
FORM prepare_new_data .
wa_ettifn_new-anlage

wa_ettifn_new-ab
wa_ettifn_new-bis
*
*
*
*
*
*
*
*
*
*
*
*

= wa_udata-anlage.

= lv_ab.
= lv_bis.

IF wa_udata-operand = 'F_EMPLOYEE'.
wa_ettifn_new-string3 = wa_udata-value.
wa_ettifn_new-operand = wa_udata-operand.
ELSEIF wa_udata-operand = 'QUARTER_NO'.
wa_ettifn_new-string1 = wa_udata-value.
wa_ettifn_new-operand = wa_udata-operand.
ELSEIF wa_udata-operand = 'EMPLOYE_NO'.
wa_ettifn_new-string1 = wa_udata-value.
wa_ettifn_new-operand = wa_udata-operand.

*
*
*
*
*

ELSEIF wa_udata-operand = 'KWH_T'.


wa_ettifn_new-wert1 = wa_udata-value.
wa_ettifn_new-operand = wa_udata-operand.
ELSE.
READ TABLE it_te221 INTO wa_te221
WITH KEY operand = wa_udata-operand BINARY SEARCH.
IF sy-subrc = 0.
IF wa_te221-optyp = 'FACTOR'.
wa_ettifn_new-wert1 = wa_udata-value.
wa_ettifn_new-operand = wa_udata-operand.
ELSEIF wa_te221-optyp = 'AMOUNT'.
wa_ettifn_new-betrag = wa_udata-value.
wa_ettifn_new-waers = 'INR'.
wa_ettifn_new-operand = wa_udata-operand.
ELSEIF wa_te221-optyp = 'INTEGER'.
wa_ettifn_new-wert1 = wa_udata-value.
wa_ettifn_new-operand = wa_udata-operand.
ELSEIF wa_te221-optyp = 'FLAG'.
wa_ettifn_new-string3 = wa_udata-value.
wa_ettifn_new-operand = wa_udata-operand.
ELSEIF wa_te221-optyp = 'USERDEF'.
wa_ettifn_new-string1 = wa_udata-value.
wa_ettifn_new-operand = wa_udata-operand.
ELSEIF wa_te221-optyp = 'QUANT'.
wa_ettifn_new-wert1 = wa_udata-value.
wa_ettifn_new-operand = wa_udata-operand.
ELSEIF wa_te221-optyp = 'DEMAND'.
wa_ettifn_new-wert1 = wa_udata-value.
wa_ettifn_new-operand = wa_udata-operand.
ELSEIF wa_te221-optyp = 'RATETYPE'.
wa_ettifn_new-kondigr = wa_udata-value.
wa_ettifn_new-operand = wa_udata-operand.
IF wa_udata-operand = 'WP_LT'.
wa_ettifn_new-tarifart = 'WP_LT'.
ELSEIF wa_udata-operand = 'WP_TRIGGER'.
wa_ettifn_new-tarifart = 'WP_ENERG'.
ENDIF.

ENDIF.
ENDIF.
ENDIF.
IF wa_ettifn_new-operand IS INITIAL.
wa_elog-anlage

= wa_udata-anlage.

wa_elog-operand = wa_udata-operand.
wa_elog-value
= wa_udata-value.
wa_elog-remark = 'Operand Not Exist'.
APPEND wa_elog TO it_elog.
CLEAR wa_elog.
ELSE.
APPEND wa_ettifn_new TO it_ettifn_new.
CLEAR wa_ettifn_new.
ENDIF.
ENDFORM.
" PREPARE_NEW_DATA
*&---------------------------------------------------------------------*
*&
Form DISPLAY_ERROR_LOG
*&---------------------------------------------------------------------*
*
text
*----------------------------------------------------------------------*
* --> p1
text
* <-- p2
text
*----------------------------------------------------------------------*
FORM display_error_log .
DATA: it_fieldcat TYPE slis_t_fieldcat_alv,
wa_fieldcat TYPE slis_fieldcat_alv.
wa_fieldcat-col_pos
= 1.
wa_fieldcat-fieldname = 'ANLAGE'.
wa_fieldcat-tabname
= 'LT_ELOG'.
wa_fieldcat-seltext_l = 'Installation'.
wa_fieldcat-outputlen = 10.
APPEND wa_fieldcat TO it_fieldcat.
CLEAR wa_fieldcat.
wa_fieldcat-col_pos
= 2.
wa_fieldcat-fieldname = 'OPERAND'.
wa_fieldcat-tabname
= 'LT_ELOG'.
wa_fieldcat-seltext_l = 'Operand'.
wa_fieldcat-outputlen = 10.
APPEND wa_fieldcat TO it_fieldcat.
CLEAR wa_fieldcat.
wa_fieldcat-col_pos
= 3.
wa_fieldcat-fieldname = 'VALUE'.
wa_fieldcat-tabname
= 'LT_ELOG'.
wa_fieldcat-seltext_l = 'Value'.
wa_fieldcat-outputlen = 10.
APPEND wa_fieldcat TO it_fieldcat.
CLEAR wa_fieldcat.
wa_fieldcat-col_pos
= 4.
wa_fieldcat-fieldname = 'REMARK'.
wa_fieldcat-tabname
= 'LT_ELOG'.
wa_fieldcat-seltext_l = 'Remark'.
wa_fieldcat-outputlen = 10.
APPEND wa_fieldcat TO it_fieldcat.
CLEAR wa_fieldcat.

CALL FUNCTION 'REUSE_ALV_GRID_DISPLAY'

EXPORTING
i_callback_program = sy-repid
i_grid_title
= 'Error Log'
it_fieldcat
= it_fieldcat
TABLES
t_outtab
= it_elog.
ENDFORM.
" DISPLAY_ERROR_LOG
*&---------------------------------------------------------------------*
*&
Form INSERT_ETTIFN_TABLE
*&---------------------------------------------------------------------*
*
text
*----------------------------------------------------------------------*
* --> p1
text
* <-- p2
text
*----------------------------------------------------------------------*
FORM insert_ettifn_table .

DATA: lv_scount TYPE char10,


lv_sstring TYPE string.

IF it_udata IS NOT INITIAL.


SELECT
FROM
INTO
FOR
WHERE
AND

*
ettifn
TABLE it_ettifn_old
ALL ENTRIES IN it_udata
anlage = it_udata-anlage
operand = it_udata-operand.

IF sy-subrc = 0.
SORT it_ettifn_old BY anlage operand bis DESCENDING .
DELETE ADJACENT DUPLICATES FROM it_ettifn_old COMPARING anlage operan
d.
ENDIF.
SELECT operand
optyp
FROM te221
INTO TABLE it_te221
FOR ALL ENTRIES IN it_udata
WHERE operand = it_udata-operand.
IF sy-subrc = 0.
SORT it_te221 BY operand.
DELETE ADJACENT DUPLICATES FROM it_te221 COMPARING operand.
SORT it_te221 BY operand.
ENDIF.

LOOP AT it_udata INTO wa_udata.

CONCATENATE wa_udata-ab+6(4) wa_udata-ab+3(2) wa_udata-ab+0(2) INT


O lv_ab.
CONCATENATE wa_udata-bis+6(4) wa_udata-bis+3(2) wa_udata-bis+0(2) INT
O lv_bis.
IF lv_ab LE lv_bis.
READ TABLE it_ettifn_old INTO wa_ettifn_old
WITH KEY anlage = wa_udata-anlage
operand = wa_udata-operand.
IF sy-subrc NE 0.
PERFORM prepare_new_data.

ELSEIF sy-subrc = 0 AND wa_ettifn_old-bis < lv_ab.


PERFORM prepare_new_data.
ELSEIF sy-subrc = 0 AND wa_ettifn_old-bis > lv_ab.
wa_elog-anlage =
wa_elog-operand =
wa_elog-value
=
wa_elog-remark =
APPEND wa_elog TO
CLEAR wa_elog.
ENDIF.
ELSE.
wa_elog-anlage =
wa_elog-operand =
wa_elog-value
=
wa_elog-remark =
APPEND wa_elog TO
CLEAR wa_elog.
ENDIF.

wa_udata-anlage.
wa_udata-operand.
wa_udata-value.
'Data Already Exist For Same Period'.
it_elog.

wa_udata-anlage.
wa_udata-operand.
wa_udata-value.
'End Date Is Less Than Start Date'.
it_elog.

ENDLOOP.
IF it_ettifn_new IS NOT INITIAL.
CALL FUNCTION 'ISU_DB_ETTIFN_UPDATE'
EXPORTING
x_upd_mode = 'I'
x_iettifn = it_ettifn_new.
IF sy-subrc = 0.
COMMIT WORK.
DESCRIBE TABLE it_ettifn_new LINES lv_scount.
CONCATENATE lv_scount text-m10
INTO lv_sstring SEPARATED BY space.
MESSAGE lv_sstring TYPE 'I'.
ENDIF.
ENDIF.
ELSE.

MESSAGE 'No Data Uploaded' TYPE 'I'.


ENDIF.
ENDFORM.
" INSERT_ETTIFN_TABLE