Sie sind auf Seite 1von 20

A/B/D

WET ROTOR CIRCULATORS


TECHNICAL DATA
Operating range: from 1 to 12 m3/h with head up to 11 metres.
Pumped liquid temperature range: from -10C to +110C.
Pumped liquid: clean, free from solids and mineral oils, not viscous,
chemically neutral, close to the characteristics of water (max 30% glycol).
Maximum working pressure: 10 bar (1000 kPa).
Protection level: IP 44
Insulation class: F
Cable grommet: PG 11
Installation: with motor axis horizontal.
Standard voltage input: single-phase 230 V / 50 Hz

three-phase 400 V/ 50 Hz
This product complies with European standard EN 60335-2-51

APPLICATIONS
Pump for hot or cold water circulation in small community central heating and air conditioning systems for both civil and industrial applications, of the closed
circuit pressurized or open circuit type.

CONSTRUCTION FEATURES
Pump body in cast iron and motor in die cast aluminium.
Impeller in technopolymer, motor shaft in hardened stainless steel held in graphite bearings lubricated by the pumping medium.
Pump body with threaded ports.
Rotor protective jacket, stator jacket, and closing flange in stainless steel.
The two-pole asynchronous wet rotor motor features three-speed operation.
Integral thermal probe in single-phase version.

DAB PUMPS reserves the right to make modifications without notice.

119

WET ROTOR CIRCULATORS

A/B/D

WET ROTOR CIRCULATORS

MATERIALS
N.

PARTS

MATERIALS

PUMP BODY

CAST IRON

IMPELLER

TECHNOPOLYMER

7A

MOTOR SHAFT

STAINLESS STEEL

7B

ROTOR

STATOR

CAPACITOR

10

MOTOR CASING

DIE CAST ALUMINIUM

11

BREATHER PLUG

BRASS

100

TERMINAL BOX

127

SEAL RING

ETHYLENE PROPYLENE

128

STATOR JACKET

STAINLESS STEEL

129

ROTOR JACKET

STAINLESS STEEL

130

CLOSING FLANGE

STAINLESS STEEL

131

THRUST RING SUPPORT

ETHYLENE PROPYLENE

132

BUSHINGS

GRAPHITE

133

THRUST RING

CERAMIC

132

7a

127

128

100

10

WET ROTOR CIRCULATORS

11

130

D 50 / 250 (.40)

Legend:
(example)
A = circulator with threaded ports
B = flanged circulator
D = twin circulator
maximum head (dm)
centre distance (mm)
( ) = 1 1/2 threaded ports
( X ) = 2 threaded ports
(.40 ) = DN40/PN10 flanged ports
M = single-phase motor
T = three-phase motor

DAB PUMPS reserves the right to make modifications without notice.

120

127

133

131

129

7b

A/B/D

WET ROTOR CIRCULATORS

PERFORMANCE RANGE

The performance curves are based on kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906.

GRAPHIC SELECTION TABLE

0,5

P
kPa

1
0,5

H
m

2
1

10

20
10

30
20

40 50
30

100

40 50

200
100

300
200

500
300

500

Q US gpm
Q IMP gpm
H
ft

150

50

15

40

90
80
70
60

50

40

30

10
9
A-B-D

30

BMH
BPH

WET ROTOR CIRCULATORS

100

7
20

DMH
DPH

10

VA - VB - VD

20

VS

10

1
0,1

0,2

0,3

0,4 0,5

0,8

0,1
2

10

20

30

4
1

0,5
40

50

6 7 8
2
100

10
3

20
4
200

30

5
300

40

50 60

10
400 500

1000

200 Q m3/h

80 100
20

30
2000

3000

Q l/s
Q l/min

DAB PUMPS reserves the right to make modifications without notice.

121

A/B/D

WET ROTOR CIRCULATORS

SELECTION TABLE - A SINGLE WITH UNIONS


Q=m3/h

0,6

1,2

1,8

2,4

4,2

7,2

12

Q=l/min

10

20

30

40

50

70

120

200

A 50/180 M

5,7

5,6

5,4

5,3

5,1

4,8

4,2

2,6

A 50/180 XM

5,7

5,6

5,4

5,3

5,1

4,8

4,2

2,6

A 50/180 T

5,6

5,6

5,6

5,5

5,43

5,4

4,9

2,8

A 50/180 XT

5,9

5,85

5,8

5,6

5,5

5,2

4,6

2,9

A 56/180 M

6,35

6,3

6,2

6,18

5,9

5,5

4,2

1,2

A 56/180 XM
A 56/180 T
A 56/180 XT
A 80/180 M
A 80/180 XM
A 80/180 T
A 80/180 XT
A 110/180 M
A 110/180 XM
A 110/180 T
A 110/180 XT

6,35

6,3

6,2

6,18

5,9

5,5

4,2

1,2

6,42

6,42

6,41

6,4

6,4

6,4

6,1

4,8

6,4

6,3

6,2

6,1

5,9

5,7

4,4

8,25

7,6

7,4

7,2

6,9

6,3

3,8

8,25

7,6

7,4

7,2

6,9

6,3

3,8

8,2

7,9

7,6

7,3

6,8

6,1

3,7

8,2

7,9

7,6

7,3

6,8

6,1

3,7

11,3

11

10,8

10,5

10

9,8

8,9

6,7

11,3

11

10,8

10,5

10

9,8

9,2

11,3

11

10,8

10,5

10

9,8

8,9

6,6

11,3

11

10,8

10,5

10

9,8

9,2

1,6

WET ROTOR CIRCULATORS

MODEL

H
(m)

1,7

SELECTION TABLE - B SINGLE WITH FLANGES


Q=m3/h

0,6

1,2

1,8

2,4

4,2

7,2

12

Q=l/min

10

20

30

40

50

70

120

200

B 50/250.40 M

5,7

5,6

5,4

5,3

5,1

4,8

4,2

2,6

B 50/250.40 T

5,9

5,85

5,8

5,6

5,5

5,2

4,6

2,9

6,35

6,3

6,2

6,18

5,9

5,5

4,2

6,4

6,3

6,2

6,1

5,9

5,7

4,4

8,25

7,6

7,4

7,2

6,9

6,3

3,8

8,2

7,9

7,6

7,3

6,8

6,1

3,7

11,3

11

10,8

10,5

10

9,8

9,2

1,7

11,3

11

10,8

10,5

10

9,8

9,2

1,6

MODEL

B 56/250.40 M
B 56/250.40 T

B 80/250.40 M

H
(m)

B 80/250.40 T

B 110/250.40 M
B 110/250.40 T

1,2

SELECTION TABLE - D TWIN WITH FLANGES


Q=m3/h

0,6

1,2

1,8

2,4

4,2

7,2

12

Q=l/min

10

20

30

40

50

70

120

200

D 50/250.40 M

5,7

5,6

5,4

5,3

5,1

4,8

4,2

2,6

D 50/250.40 T
D 56/250.40 M
D 56/250.40 T
D 80/250.40 M
D 80/250.40 T
D 110/250.40 M
D 110/250.40 T

5,9

5,85

5,8

5,6

5,5

5,2

4,6

2,9

6,35

6,3

6,2

6,18

5,9

5,5

4,2

5,9

5,85

5,8

5,6

5,5

5,2

4,6

2,9

8,25

7,6

7,4

7,2

6,9

6,3

3,8

8,2

7,9

7,6

7,3

6,8

6,1

3,7

11,3

11

10,8

10,5

10

9,8

9,2

1,7

11,3

11

10,8

10,5

10

9,8

9,2

1,6

MODEL

H
(m)

DAB PUMPS reserves the right to make modifications without notice.

122

1,2

A50/180 M - HEATING, AIR CONDITIONING

Pumped liquid temperature range: from -10 C to +110 C - Maximum operating pressure: 10 bar (1000 kPa)
H

H1

L1

H2

L2
B1
B

B2
The performance curves are based on kinematic viscosity values =
1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906.

A50/180 M

POWER INPUT
50 Hz

180

MODEL
A50/180 M

UNIONS ON
REQUEST

1x230 V ~

SPEED

REV.
1/min

3
2
1

2766
2616
2215

ELECTRICAL DATA
P1 MAX
In
W
A
195
194
180

MINIMUM SUCTION PRESSURE


CAPACITOR
F
Vc

0,95
0,95
0,85

400

90

m.c.a.

1,5

PACKING DIMENSIONS

L1

L2

B1

B2

H1

H2

180

90

90

173

34

139

143

52

92

1 1/2

206

170

180

VOLUME
m3

WEIGHT
kg

0,066

A50/180 XM - HEATING, AIR CONDITIONING

Pumped liquid temperature range: from -10 C to +110 C - Maximum operating pressure: 10 bar (1000 kPa)
H

H1

L1

H2

P
kPa

H
m

60

50

40

30

20

10

L2
B1
B

B2

0
0

10
5

0,5

15
10

20
15

25

30

20

35

25
1,5

40

30

45
35

Q USgpm

40 Q IMPgpm
V m/s 1"
H
230 V~ 50 Hz ft
20
16
12
8
4

0
0
0

2
0,5

20

40

60

5
80

1,5

100

120

9
2,5
140

10
160

11
3

0
Q m3/h
Q l/s

180

Q l/min

The performance curves are based on kinematic viscosity values =


1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906.

MODEL

CENTRE
DISTANCE
mm

A50/180 XM

MODEL
A50/180 XM

POWER INPUT
50 Hz

180

UNIONS ON
REQUEST

1x230 V ~

1 1/4

SPEED

REV.
1/min

3
2
1

2791
2651
2297

ELECTRICAL DATA
P1 MAX
In
W
A
184
189
168

MINIMUM SUCTION PRESSURE


CAPACITOR
F
Vc

0,92
0,92
0,80

L1

L2

B1

B2

H1

H2

180

90

90

173

34

139

143

52

92

2 G

400

PACKING DIMENSIONS
L

206

170

180

90

m.c.a.

1,5

VOLUME
m3

WEIGHT
kg

0,066

5,3

DAB PUMPS reserves the right to make modifications without notice.

123

WET ROTOR CIRCULATORS

CENTRE
DISTANCE
mm

MODEL

A50/180 T - HEATING, AIR CONDITIONING

Pumped liquid temperature range: from -10 C to +110 C - Maximum operating pressure: 10 bar (1000 kPa)
H

H1

L1

H2

P
kPa

H
m

60

50

40

30

20

10

L2
B1
B

B2

0
0

10

15

5
0,2

20

10
0,4

25

15
0,6

30

20
0,8

35

Q USgpm

30 Q IMPgpm
V m/s 1" 1/2
H
400 V~ 50 Hz ft
20

25
1

16
12
8
4

0
0
0

2
0,5

20

40

1,5

80

60

100

0
Q m3/h
Q l/s

140 Q l/min

120

The performance curves are based on kinematic viscosity values =


1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906.

MODEL

CENTRE
DISTANCE
mm

POWER INPUT
50 Hz

UNIONS ON
REQUEST

180

3x400 V ~

WET ROTOR CIRCULATORS

A50/180 T

MODEL
A50/180 T

ELECTRICAL DATA
P1 MAX
In
W
A

SPEED

REV.
1/min

2827

197

0,52

2502

139

0,25

MINIMUM SUCTION PRESSURE


CAPACITOR
F
Vc

90

m.c.a.

1,5

PACKING DIMENSIONS

L1

L2

B1

B2

H1

H2

180

90

90

173

34

139

143

52

92

1 1/2

206

170

180

VOLUME
m3

WEIGHT
kg

0,066

5,3

A50/180 XT - HEATING, AIR CONDITIONING

Pumped liquid temperature range: from -10 C to +110 C - Maximum operating pressure: 10 bar (1000 kPa)
H

H1

L1

H2
P
kPa

H
m

60

50

40

30

20

10

L2
B1
B

B2

0
0

10
5

0,5

15
10

20
15

25

30

20

35

25
1,5

40

30

45
35

Q USgpm

40 Q IMPgpm
V m/s 1"
H
400 V~ 50 Hz ft
20
16
12
8
4

0
0
0

2
0,5

20

3
40

60

5
80

1,5

100

9
2,5
140

120

10
160

11
3

0
Q m3/h
Q l/s

180

Q l/min

The performance curves are based on kinematic viscosity values =


1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906.

MODEL

CENTRE
DISTANCE
mm

POWER INPUT
50 Hz

UNIONS ON
REQUEST

180

3x400 V ~

1 1/4

A50/180 XT

MODEL
A50/180 XT

SPEED
2

2838

201

0,50

2520

129

0,23

L1

L2

B1

B2

H1

H2

180

90

90

173

34

139

143

52

92

2 G

DAB PUMPS reserves the right to make modifications without notice.

124

ELECTRICAL DATA
P1 MAX
In
W
A

REV.
1/min

MINIMUM SUCTION PRESSURE


CAPACITOR
F
Vc

PACKING DIMENSIONS
L

206

170

180

90

m.c.a.

1,5

VOLUME
m3

WEIGHT
kg

0,066

5,2

A56/180 M - HEATING, AIR CONDITIONING

Pumped liquid temperature range: from -10 C to +110 C - Maximum operating pressure: 10 bar (1000 kPa)
H

H1

L1

H2

L2
B1
B

B2
The performance curves are based on kinematic viscosity values =
1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906.

CENTRE
DISTANCE
mm

POWER INPUT
50 Hz

UNIONS ON
REQUEST

180

1x230 V ~

A56/180 M

MODEL
A56/180 M

SPEED

REV.
1/min

3
2
1

2636
2226
1485

ELECTRICAL DATA
P1 MAX
In
W
A
282
287
228

MINIMUM SUCTION PRESSURE


CAPACITOR
F
Vc

1,23
1,30
1,06

400

PACKING DIMENSIONS

L1

L2

B1

B2

H1

H2

180

90

90

173

34

139

143

52

92

1 1/2

206

170

180

90

m.c.a.

1,5

VOLUME
m3

WEIGHT
kg

0,066

5,3

A56/180 XM - HEATING, AIR CONDITIONING

Pumped liquid temperature range: from -10 C to +110 C - Maximum operating pressure: 10 bar (1000 kPa)
H

H1

L1

H2

10

0
0

10
0,5

20
1

30
20

40
30

1,5

50

60

40
2,5

Q USgpm

50
3

Q IMPgpm
V m/s 1"
H
230 V~ 50 Hz ft

P
kPa

H
m

60

20

16

40

L2

12

3
20

B1
B

1
0

B2

50

100

10

12

150

14

200

0
Q m3/h

Q l/s

250 Q l/min

The performance curves are based on kinematic viscosity values =


1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906.

MODEL

CENTRE
DISTANCE
mm

POWER INPUT
50 Hz

UNIONS ON
REQUEST

180

1x230 V ~

1 1/4

A56/180 XM

MODEL
A56/180 XM

SPEED

REV.
1/min

3
2
1

2658
2117
1394

ELECTRICAL DATA
P1 MAX
In
W
A
271
294
224

MINIMUM SUCTION PRESSURE


CAPACITOR
F
Vc

1,18
1,32
1,00

L1

L2

B1

B2

H1

H2

180

90

90

173

34

139

143

52

92

2 G

400

PACKING DIMENSIONS
L

206

170

180

90

m.c.a.

1,5

VOLUME
m3

WEIGHT
kg

0,066

5,3

DAB PUMPS reserves the right to make modifications without notice.

125

WET ROTOR CIRCULATORS

MODEL

A56/180 T - HEATING, AIR CONDITIONING

Pumped liquid temperature range: from -10 C to +110 C - Maximum operating pressure: 10 bar (1000 kPa)
H

H1

L1

H2

0
0

10

20
10
0,4

0,2

30
20
0,8

0,6

40
30
1,2

Q USgpm

40 Q IMPgpm
V m/s 1"1/2
1,4
H
400 V~ 50 Hz ft

P
kPa

H
m

60

20

16

40

L2

12

3
20

B1
B

1
0

B2

50

10

100

0
Q m3/h

Q l/s

150

Q l/min

The performance curves are based on kinematic viscosity values =


1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906.

MODEL

CENTRE
DISTANCE
mm

POWER INPUT
50 Hz

UNIONS ON
REQUEST

180

3x400 V ~

WET ROTOR CIRCULATORS

A56/180 T

MODEL
A56/180 T

ELECTRICAL DATA
P1 MAX
In
W
A

SPEED

REV.
1/min

2704

294

0,60

2178

200

0,33

MINIMUM SUCTION PRESSURE


CAPACITOR
F
Vc

PACKING DIMENSIONS

L1

L2

B1

B2

H1

H2

180

90

90

173

34

139

143

52

92

1 1/2

206

170

180

90

m.c.a.

1,5

VOLUME
m3

WEIGHT
kg

0,066

5,2

A56/180 XT - HEATING, AIR CONDITIONING

Pumped liquid temperature range: from -10 C to +110 C - Maximum operating pressure: 10 bar (1000 kPa)
H

H1

L1

H2

10

0
0

10
0,5

20
1

30
20

40
30

1,5

50

60

40
2,5

Q USgpm

50
3

Q IMPgpm
V m/s 1"
H
400 V~ 50 Hz ft

P
kPa

H
m

60

20

16

40

L2

12

3
20

B1
B

1
0

B2

50

100

10

12

150

14

200

0
Q m3/h

Q l/s

250 Q l/min

The performance curves are based on kinematic viscosity values =


1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906.

MODEL

CENTRE
DISTANCE
mm

POWER INPUT
50 Hz

UNIONS ON
REQUEST

180

3x400 V ~

1 1/4

A56/180 XT

MODEL
A56/180 XT

SPEED
2

2708

291

0,60

2178

200

0,32

L1

L2

B1

B2

H1

H2

180

90

90

173

34

139

143

52

92

2 G

DAB PUMPS reserves the right to make modifications without notice.

126

ELECTRICAL DATA
P1 MAX
In
W
A

REV.
1/min

MINIMUM SUCTION PRESSURE


CAPACITOR
F
Vc

PACKING DIMENSIONS
L

206

170

180

90

m.c.a.

1,5

VOLUME
m3

WEIGHT
kg

0,066

5,3

A80/180 M - HEATING, AIR CONDITIONING

Pumped liquid temperature range: from -10 C to +110 C - Maximum operating pressure: 10 bar (1000 kPa)
H

H1

L1

H2

10

15

5
0,2

20

10
0,4

25

15
0,6

30

20
0,8

35

25
1

40 Q USgpm

30
1,2

Q IMPgpm
V m/s 1"1/2
H
230 V~ 50 Hz ft

P
kPa

H
m
8

70

60

20

50

16

40

30

20

10

L2
B1
B

0
0

B2

24

12
8
4
0

0,5

20

40

60

1,5

80

100

0
Q m3/h

2,5

120

Q l/s

140

Q l/min

The performance curves are based on kinematic viscosity values =


1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906.

A80/180 M

POWER INPUT
50 Hz

180

MODEL
A80/180 M

UNIONS ON
REQUEST

1x230 V ~

SPEED

REV.
1/min

3
2
1

2674
2356
1615

ELECTRICAL DATA
P1 MAX
In
W
A
264
262
223

MINIMUM SUCTION PRESSURE


CAPACITOR
F
Vc

1,15
1,20
1,00

400

90

m.c.a.

2,5

PACKING DIMENSIONS

L1

L2

B1

B2

H1

H2

180

90

90

173

34

139

143

52

92

1 1/2

206

170

180

VOLUME
m3

WEIGHT
kg

0,066

5,3

A80/180 XM - HEATING, AIR CONDITIONING

Pumped liquid temperature range: from -10 C to +110 C - Maximum operating pressure: 10 bar (1000 kPa)
H

H1

L1

H2

10
5

0,5

15
10

20
15

25

30

20

35

25
1,5

40

30

45
35

Q USgpm

40 Q IMPgpm
V m/s 1"
H
230 V~ 50 Hz ft

P
kPa

H
m
8

70

60

20

50

16

40

30

20

10

L2
B1
B

0
0

B2

24

12
8
4
0

0
0

0,5

20

40

60

5
80

1,5

100

120

2,5
140

10
160

11

180

0
Q m3/h

Q l/s

Q l/min

The performance curves are based on kinematic viscosity values =


1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906.

MODEL

CENTRE
DISTANCE
mm

POWER INPUT
50 Hz

UNIONS ON
REQUEST

180

1x230 V ~

1 1/4

A80/180 XM

MODEL
A80/180 XM

SPEED

REV.
1/min

3
2
1

2683
2374
1688

ELECTRICAL DATA
P1 MAX
In
W
A
256
260
218

MINIMUM SUCTION PRESSURE


CAPACITOR
F
Vc

1,12
1,17
1,00

L1

L2

B1

B2

H1

H2

180

90

90

173

34

139

143

52

92

2 G

400

PACKING DIMENSIONS
L

206

170

180

90

m.c.a.

2,5

VOLUME
m3

WEIGHT
kg

0,066

5,2

DAB PUMPS reserves the right to make modifications without notice.

127

WET ROTOR CIRCULATORS

CENTRE
DISTANCE
mm

MODEL

A80/180 T - HEATING, AIR CONDITIONING

Pumped liquid temperature range: from -10 C to +110 C - Maximum operating pressure: 10 bar (1000 kPa)
H

H1

L1

H2

10

15

5
0,2

20

10
0,4

25

15
0,6

30

20
0,8

35

25
1

40 Q USgpm

30
1,2

Q IMPgpm
V m/s 1"1/2
H
400 V~ 50 Hz ft

P
kPa

H
m
8

70

60

20

50

16

40

30

20

10

L2
B1
B

0
0

B2

24

12
8
4
0

0,5

20

40

60

1,5

80

100

120

0
Q m3/h

2,5

Q l/s

140

Q l/min

The performance curves are based on kinematic viscosity values =


1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906.

MODEL

CENTRE
DISTANCE
mm

POWER INPUT
50 Hz

UNIONS ON
REQUEST

180

3x400 V ~

WET ROTOR CIRCULATORS

A80/180 T

MODEL
A80/180 T

ELECTRICAL DATA
P1 MAX
In
W
A

SPEED

REV.
1/min

2724

271

0,57

2226

187

0,31

MINIMUM SUCTION PRESSURE


CAPACITOR
F
Vc

90

m.c.a.

2,5

PACKING DIMENSIONS

L1

L2

B1

B2

H1

H2

180

90

90

173

34

139

143

52

92

1 1/2

206

170

180

VOLUME
m3

WEIGHT
kg

0,066

5,3

A80/180 XT - HEATING, AIR CONDITIONING

Pumped liquid temperature range: from -10 C to +110 C - Maximum operating pressure: 10 bar (1000 kPa)
H

H1

L1

H2

10
5

0,5

15
10

20
15

25

30

20

35

25
1,5

40

30

45
35

Q USgpm

40 Q IMPgpm
V m/s 1"
H
400 V~ 50 Hz ft

P
kPa

H
m
8

70

60

20

50

16

40

30

20

10

L2
B1
B

0
0

B2

24

12
8
4
0

0
0

0,5

20

40

60

5
80

1,5

100

120

2,5
140

10

11

160

180

0
Q m3/h

Q l/s

Q l/min

The performance curves are based on kinematic viscosity values =


1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906.

MODEL

CENTRE
DISTANCE
mm

POWER INPUT
50 Hz

UNIONS ON
REQUEST

180

3x400 V ~

A80/180 XT

MODEL
A80/180 XT

SPEED
2

2727

272

0,57

2227

186

0,30

L1

L2

B1

B2

H1

H2

180

90

90

173

34

139

143

52

92

2 G

DAB PUMPS reserves the right to make modifications without notice.

128

ELECTRICAL DATA
P1 MAX
In
W
A

REV.
1/min

MINIMUM SUCTION PRESSURE


CAPACITOR
F
Vc

PACKING DIMENSIONS
L

206

170

180

90

m.c.a.

2,5

VOLUME
m3

WEIGHT
kg

0,066

5,3

A110/180 M - HEATING, AIR CONDITIONING

Pumped liquid temperature range: from -10 C to +110 C - Maximum operating pressure: 10 bar (1000 kPa)
H

H1

H2
P
kPa

L1

10

90

80

70

60

50

40

30

20

10

B1

20

30

10
0,4

40

20
0,8

50

30
1,2

40
1,6

B2

Q USgpm
Q IMPgpm
V m/s 1"1/2
H
230 V~ 50 Hz ft

11

100

L2

10

0
H0
m

30
25
20
15
10
5

0,5

20

1
40

1,5

60

80

10

2
100

120

140

12

2,5

3
160

Q m3/h
3,5

180

200

Q l/s
220 Q l/min

The performance curves are based on kinematic viscosity values =


1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906.

A110/180 M

POWER INPUT
50 Hz

180

MODEL
A110/180 M

UNIONS ON
REQUEST

1x230 V ~

2 G

SPEED

REV.
1/min

3
2
1

2746
2552
2052

ELECTRICAL DATA
P1 MAX
In
W
A
410
393
361

MINIMUM SUCTION PRESSURE


CAPACITOR
F
Vc

1,6
1,8
1,7

12

450

90

m.c.a.

2,5

PACKING DIMENSIONS

L1

L2

B1

B2

H1

H2

180

93

87

229

42

186

167

70

97

1 1/2 G

237

200

272

VOLUME
m3

WEIGHT
kg

0,066

5,3

A110/180 XM - HEATING, AIR CONDITIONING

Pumped liquid temperature range: from -10 C to +110 C - Maximum operating pressure: 10 bar (1000 kPa)
H

H1

H2
P
kPa

L1

10

90

80

70

60

50

40

30

20

10

B1

B2

20
10
0,4

30

40

20
0,8

50

30
1,2

40
1,6

11

100

L2

10

0
H0
m

Q USgpm
Q IMPgpm
V m/s 1"1/2
H
230 V~ 50 Hz ft
30
25
20
15
10
5

0
0

0,5
20

1
40

60

1,5
80

100

2
120

10

2,5
140

160

3
180

12
200

Q m3/h

3,5

Q l/s

220 Q l/min

The performance curves are based on kinematic viscosity values =


1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906.

MODEL

CENTRE
DISTANCE
mm

POWER INPUT
50 Hz

UNIONS ON
REQUEST

180

1x230 V ~

1 1/4

A110/180 XM

MODEL
A110/180 XM

SPEED

REV.
1/min

3
2
1

2746
2552
2052

ELECTRICAL DATA
P1 MAX
In
W
A
195
194
180

MINIMUM SUCTION PRESSURE


CAPACITOR
F
Vc

410
393
361

L1

L2

B1

B2

H1

H2

180

93

87

229

42

186

167

70

97

2 G

12

450

PACKING DIMENSIONS
L

237

200

272

90

m.c.a.

2,5

VOLUME
m3

WEIGHT
kg

0,066

5,3

DAB PUMPS reserves the right to make modifications without notice.

129

WET ROTOR CIRCULATORS

CENTRE
DISTANCE
mm

MODEL

A110/180 T - HEATING, AIR CONDITIONING

Pumped liquid temperature range: from -10 C to +110 C - Maximum operating pressure: 10 bar (1000 kPa)
H

H1

H2
400 V~ 50 Hz

L1

L2
B1

B2

The performance curves are based on kinematic viscosity values =


1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906.

MODEL

CENTRE
DISTANCE
mm

POWER INPUT
50 Hz

UNIONS ON
REQUEST

180

3x400 V ~

2 G

WET ROTOR CIRCULATORS

A110/180 T

MODEL
A110/180 T

ELECTRICAL DATA
P1 MAX
In
W
A

SPEED

REV.
1/min

2753

402

0,87

2338

286

0,48

MINIMUM SUCTION PRESSURE


CAPACITOR
F
Vc

PACKING DIMENSIONS

L1

L2

B1

B2

H1

H2

180

93

87

229

186

42

163

70

93

1 1/2 G

237

200

272

90

m.c.a.

2,5

VOLUME
m3

WEIGHT
kg

0,066

5,2

A110/180 XT - HEATING, AIR CONDITIONING

Pumped liquid temperature range: from -10 C to +110 C - Maximum operating pressure: 10 bar (1000 kPa)
H

H1

H2
400 V~ 50 Hz

L1

L2
B1

B2

The performance curves are based on kinematic viscosity values =


1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906.

MODEL

CENTRE
DISTANCE
mm

POWER INPUT
50 Hz

UNIONS ON
REQUEST

180

3x400 V ~

2 G

A110/180 XT

MODEL
A110/180 XT

SPEED
2

2759

403

0,90

2341

289

0,48

L1

L2

B1

B2

H1

H2

180

93

87

229

186

42

163

70

93

2 G

DAB PUMPS reserves the right to make modifications without notice.

130

ELECTRICAL DATA
P1 MAX
In
W
A

REV.
1/min

MINIMUM SUCTION PRESSURE


CAPACITOR
F
Vc

PACKING DIMENSIONS
L

237

200

272

90

m.c.a.

2,5

VOLUME
m3

WEIGHT
kg

0,066

5,2

B50/250.40 M - HEATING, AIR CONDITIONING

Pumped liquid temperature range: from -10 C to +110 C - Maximum operating pressure: 10 bar (1000 kPa)
H1

L1

H2

D
P
kPa

H
m

60

50

40

30

20

10

D1
D2
D4

L2
B1
B

B2

0
0

10
5

0,5

15

20

10

15

25

30

20

35

25
1,5

40

30

45
35

Q USgpm

40 Q IMPgpm
V m/s 1"
H
230 V~ 50 Hz ft
20
16
12
8
4

0
0

2
0,5

20

40

5
80

60

1,5

100

9
2,5
140

120

10
160

11
3

0
Q m3/h
Q l/s

180

Q l/min

The performance curves are based on kinematic viscosity values =


1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906.

B50/250.40 M

POWER INPUT
50 Hz

250

MODEL
B50/250.40 M

UNIONS ON
REQUEST

1x230 V ~

SPEED

REV.
1/min

3
2
1

2766
2616
2215

DN 40

ELECTRICAL DATA
P1 MAX
In
W
A
195
194
180

MINIMUM SUCTION PRESSURE


CAPACITOR
F
Vc

0,95
0,95
0,85

400

90

m.c.a.

1,5

PACKING DIMENSIONS

L1

L2

B1

B2

D1

D2

D3

D4

H1

H2

250

125

125

204

65

139

150

110

100

80

40

167

75

92

DN40/PN10

302

202

283

VOLUME
m3

WEIGHT
kg

0,013

9,1

B50/250.40 T - HEATING, AIR CONDITIONING

Pumped liquid temperature range: from -10 C to +110 C - Maximum operating pressure: 10 bar (1000 kPa)
H1

L1

H2

D1
D2
D4

L2
B1
B

P
kPa

H
m

60

50

40

30

20

10

B2

0
0

10
5

0,5

15

20

10

15

25

30

20

35

25
1,5

40

30

45
35

Q USgpm

40 Q IMPgpm
V m/s 1"
H
400 V~ 50 Hz ft
20
16
12
8
4

0
0

2
0,5

20

3
40

1
60

1,5

80

6
100

120

9
2,5
140

10
160

11
3

0
Q m3/h
Q l/s

180

Q l/min

The performance curves are based on kinematic viscosity values =


1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906.

MODEL

CENTRE
DISTANCE
mm

POWER INPUT
50 Hz

UNIONS ON
REQUEST

250

3x400 V ~

DN 40

B50/250.40 T

MODEL
B50/250.40 T

ELECTRICAL DATA
P1 MAX
In
W
A

SPEED

REV.
1/min

2838

201

0,5

2520

129

0,23

L1

L2

B1

B2

D1

D2

D3

D4

H1

H2

250

125

125

204

65

139

150

110

100

80

40

167

75

92

DN40/PN10

MINIMUM SUCTION PRESSURE


CAPACITOR
F
Vc

PACKING DIMENSIONS
L

302

202

283

90

m.c.a.

1,5

VOLUME
m3

WEIGHT
kg

0,013

9,3

DAB PUMPS reserves the right to make modifications without notice.

131

WET ROTOR CIRCULATORS

CENTRE
DISTANCE
mm

MODEL

B56/250.40 M - HEATING, AIR CONDITIONING

Pumped liquid temperature range: from -10 C to +110 C - Maximum operating pressure: 10 bar (1000 kPa)
H1

H2

L1

20

30
20

40
30

1,5

50

60

40
2,5

Q USgpm

50
3

Q IMPgpm
V m/s 1"
H
230 V~ 50 Hz ft

60

20

16

12

3
20

B1
B

10
0,5

H
m

D1
D2
D4

L2

10

P
kPa

40

0
0
0

B2

50

100

10

12

150

14

0
Q m3/h

200

Q l/s

250 Q l/min

The performance curves are based on kinematic viscosity values =


1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906.

CENTRE
DISTANCE
mm

MODEL

WET ROTOR CIRCULATORS

B56/250.40 M

POWER INPUT
50 Hz

250

MODEL
B56/250.40 M

UNIONS ON
REQUEST

1x230 V ~

SPEED

REV.
1/min

3
2
1

2658
2117
1394

DN 40

ELECTRICAL DATA
P1 MAX
In
W
A
271
294
224

MINIMUM SUCTION PRESSURE


CAPACITOR
F
Vc

1,18
1,32
1

400

90

m.c.a.

1,5

PACKING DIMENSIONS

L1

L2

B1

B2

D1

D2

D3

D4

H1

H2

250

125

125

204

65

139

150

110

100

80

40

167

75

92

DN40/PN10

302

202

283

VOLUME
m3

WEIGHT
kg

0,013

9,3

B56/250.40 T - HEATING, AIR CONDITIONING

Pumped liquid temperature range: from -10 C to +110 C - Maximum operating pressure: 10 bar (1000 kPa)
H1

H2

20
1

30
20

40
30

1,5

50

60

40
2,5

Q USgpm

50
3

Q IMPgpm
V m/s 1"
H
400 V~ 50 Hz ft

60

20

16

12

3
20

B1
B

10
0,5

H
m

D1
D2
D4

L2

10

P
kPa

40

L1

0
0
0

B2

50

100

10
150

12

14

200

0
Q m3/h

Q l/s

250 Q l/min

The performance curves are based on kinematic viscosity values =


1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906.

MODEL

CENTRE
DISTANCE
mm

POWER INPUT
50 Hz

UNIONS ON
REQUEST

250

3x400 V ~

DN 40

B56/250.40 T

MODEL
B56/250.40 T

SPEED
2

2708

291

0,6

2178

200

0,32

L1

L2

B1

B2

D1

D2

D3

D4

H1

H2

250

125

125

204

65

139

150

110

100

80

40

167

75

92

DN40/PN10

DAB PUMPS reserves the right to make modifications without notice.

132

ELECTRICAL DATA
P1 MAX
In
W
A

REV.
1/min

MINIMUM SUCTION PRESSURE


CAPACITOR
F
Vc

PACKING DIMENSIONS
L

302

202

283

90

m.c.a.

1,5

VOLUME
m3

WEIGHT
kg

0,013

9,2

B80/250.40 M - HEATING, AIR CONDITIONING

Pumped liquid temperature range: from -10 C to +110 C - Maximum operating pressure: 10 bar (1000 kPa)
H1

L1

H2

0,5

15
10

20
15

25

30

20

35

25
1,5

40

30

45
35

Q USgpm

40 Q IMPgpm
V m/s 1"
H
230 V~ 50 Hz ft

H
m
8

70

60

20

50

16

40

30

20

10

B1
B

10
5

P
kPa

D1
D2
D4

L2

0
0

24

12
8
4
0

B2

0,5

20

40

60

1,5

80

100

120

10

2,5
140

11

160

0
Q m3/h

Q l/s

180

Q l/min

The performance curves are based on kinematic viscosity values =


1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906.

B80/250.40 M

POWER INPUT
50 Hz

250

MODEL
B80/250.40 M

UNIONS ON
REQUEST

1x230 V ~

SPEED

REV.
1/min

3
2
1

2683
2374
1688

DN 40

ELECTRICAL DATA
P1 MAX
In
W
A
256
260
218

MINIMUM SUCTION PRESSURE


CAPACITOR
F
Vc

1,12
1,17
1,00

400

90

m.c.a.

2,5

PACKING DIMENSIONS

L1

L2

B1

B2

D1

D2

D3

D4

H1

H2

250

125

125

204

65

139

150

110

100

80

40

167

75

92

DN40/PN10

302

202

283

VOLUME
m3

WEIGHT
kg

0,013

9,3

B80/250.40 T - HEATING, AIR CONDITIONING

Pumped liquid temperature range: from -10 C to +110 C - Maximum operating pressure: 10 bar (1000 kPa)
H1

L1

H2

0,5

15
10

20
15

25

30

20

35

25
1,5

40

30

45
35

Q USgpm

40 Q IMPgpm
V m/s 1"
H
400 V~ 50 Hz ft

H
m
8

70

60

20

50

16

40

30

20

10

B1
B

10
5

P
kPa

D1
D2
D4

L2

0
0

24

12
8
4
0

B2

0,5

20

40

60

80

1,5

100

120

10

2,5
140

11

160

180

0
Q m3/h

Q l/s

Q l/min

The performance curves are based on kinematic viscosity values =


1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906.

MODEL

CENTRE
DISTANCE
mm

POWER INPUT
50 Hz

UNIONS ON
REQUEST

250

3x400 V ~

DN 40

B80/250.40 T

MODEL
B80/250.40 T

ELECTRICAL DATA
P1 MAX
In
W
A

SPEED

REV.
1/min

2724

271

0,57

2226

187

0,31

MINIMUM SUCTION PRESSURE


CAPACITOR
F
Vc

L1

L2

B1

B2

D1

D2

D3

D4

H1

H2

250

125

125

204

65

139

150

110

100

80

40

167

75

92

DN40/PN10

PACKING DIMENSIONS
L

302

202

283

90

m.c.a.

2,5

VOLUME
m3

WEIGHT
kg

0,013

9,3

DAB PUMPS reserves the right to make modifications without notice.

133

WET ROTOR CIRCULATORS

CENTRE
DISTANCE
mm

MODEL

B110/250.40 M - HEATING, AIR CONDITIONING

Pumped liquid temperature range: from -10 C to +110 C - Maximum operating pressure: 10 bar (1000 kPa)
H
H2 H2

D D3D D3

H
H1 H1

P
kPa

D1
D2
D1
D4
D2
D4

10

0
H0
m

20

30

10
0,4

40

20
0,8

50

30
1,2

40
1,6

11

L2

L1

90

80

70

60

50

40

30

20

10

Q IMPgpm
V m/s 1"1/2
H
230 V~ 50 Hz ft
30
25
20
15
10
5

0,5

B2 B2
B

10

B1 B1

100

Q USgpm

20

1
40

60

1,5
80

10

2
100

120

2,5
140

12

Q m3/h

3
160

180

3,5
200

Q l/s
220 Q l/min

The performance curves are based on kinematic viscosity values =


1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906.

H
D D3

H2

H1

MODEL

CENTRE
DISTANCE
mm
250

250

125

L2

3
2
1

2746
2552
2052

ELECTRICAL DATA
P1 MAX
In
W
A
410
393
361

1,77
1,78
1,64

B2

D1

D2

D3

D4

H1

H2

186

150

110

100

80

40

172

75

97

DN40/PN10

125

256

70

MINIMUM SUCTION PRESSURE


CAPACITOR
F
Vc
12

B1

L2 L2

L1

SPEED

REV.
1/min

DN 40

B110/250.40 M

D1
D2
D4

1x230 V ~

L1 L1

MODEL

UNIONS ON
REQUEST

450

90

m.c.a.

2,5

PACKING DIMENSIONS
L

302

202

283

VOLUME
m3

WEIGHT
kg

0,013

9,2

B1

WET ROTOR CIRCULATORS

B110/250.40 M

POWER INPUT
50 Hz

B2

B110/250.40 T - HEATING, AIR CONDITIONING

Pumped liquid temperature range: from -10 C to +110 C - Maximum operating pressure: 10 bar (1000 kPa)
H
D D3D D3

H2 H2

H
H1 H1

400 V~ 50 Hz

D1
D2
D1
D4
D2
D4

L2

L1

B1 B1
B
B2 B2
B

The performance curves are based on kinematic viscosity values =


1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906.

H
D D3

H2

H1

MODEL

CENTRE
DISTANCE
mm

POWER INPUT
50 Hz

UNIONS ON
REQUEST

250

3x400 V ~

DN 40

B110/250.40 T

MODEL
B110/250.40 T

D1
D2
D4

SPEED
2

2759

403

0,90

2341

289

0,48

MINIMUM SUCTION PRESSURE


CAPACITOR
F
Vc

L1

L2

B1

B2

D1

D2

D3

D4

H1

H2

250

125

125

256

70

186

150

110

100

80

40

168

75

93

DN40/PN10

B1
B
B2

DAB PUMPS reserves the right to make modifications without notice.

134

ELECTRICAL DATA
P1 MAX
In
W
A

REV.
1/min

PACKING DIMENSIONS
L

302

202

283

90

m.c.a.

2,5

VOLUME
m3

WEIGHT
kg

0,013

9,3

D50/250.40 M - HEATING, AIR CONDITIONING

Pumped liquid temperature range: from -10 C to +110 C - Maximum operating pressure: 10 bar (1000 kPa)

H1

H2

D
D3

P
kPa

H
m

60

50

40

30

20

10

L2
L
L1

D1
D2
D4
B1
B

B2

0
0

10
5

15

20

10

0,5

15

25

30

20

35

25
1,5

40

30

45
35

Q USgpm

40 Q IMPgpm
V m/s 1"
H
230 V~ 50 Hz ft
20
16
12
8
4

0
0

2
0,5

20

40

1,5

80

60

100

9
2,5
140

120

10
160

11
3

0
Q m3/h
Q l/s

180

Q l/min

The performance curves are based on kinematic viscosity values =


1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906.

D50/250.40 M

POWER INPUT
50 Hz

250

MODEL
D50/250.40 M

UNIONS ON
REQUEST

1x230 V ~

SPEED

REV.
1/min

3
2
1

2766
2616
2215

DN 40 - PN 10

ELECTRICAL DATA
P1 MAX
In
W
A
195
194
180

MINIMUM SUCTION PRESSURE


CAPACITOR
F
Vc

0,95
0,95
0,85

400

90

m.c.a.

1,5

PACKING DIMENSIONS

L1

L2

B1

B2

D1

D2

D3

D4

H1

H2

250

125

125

204

65

139

150

110

100

80

40

247

122

126

DN40/PN10

335

298

283

VOLUME
m3

WEIGHT
kg

0,018

15,3

D50/250.40 T - HEATING, AIR CONDITIONING

Pumped liquid temperature range: from -10 C to +110 C - Maximum operating pressure: 10 bar (1000 kPa)
H1

H2

D
D3

P
kPa

H
m

60

50

40

30

20

10

L2
L
L1

D1
D2
D4
B1
B

B2

0
0

10
5

0,5

15
10

20
15

25

30

20

35

25
1,5

40

30

45
35

Q USgpm

40 Q IMPgpm
V m/s 1"
H
400 V~ 50 Hz ft
20
16
12
8
4

0
0

2
0,5

20

3
40

1,5

80

60

100

9
2,5
140

120

10
160

11
3

0
Q m3/h
Q l/s

180

Q l/min

The performance curves are based on kinematic viscosity values =


1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906.

MODEL

CENTRE
DISTANCE
mm

POWER INPUT
50 Hz

UNIONS ON
REQUEST

250

3x400 V ~

DN 40 - PN 10

D50/250.40 T

MODEL
D50/250.40 T

ELECTRICAL DATA
P1 MAX
In
W
A

SPEED

REV.
1/min

2838

201

0,50

2520

129

0,23

MINIMUM SUCTION PRESSURE


CAPACITOR
F
Vc

L1

L2

B1

B2

D1

D2

D3

D4

H1

H2

250

125

125

204

65

139

150

110

100

80

40

247

122

126

DN40/PN10

PACKING DIMENSIONS
L

335

298

283

90

m.c.a.

1,5

VOLUME
m3

WEIGHT
kg

0,018

15,8

DAB PUMPS reserves the right to make modifications without notice.

135

WET ROTOR CIRCULATORS

CENTRE
DISTANCE
mm

MODEL

D56/250.40 M - HEATING, AIR CONDITIONING

Pumped liquid temperature range: from -10 C to +110 C - Maximum operating pressure: 10 bar (1000 kPa)
H1

H2

D
D3

10
10
0,5

20
1

30
20

40
30

1,5

50

60

40
2,5

Q USgpm

50
3

Q IMPgpm
V m/s 1"
H
230 V~ 50 Hz ft

P
kPa

H
m

60

20

16

L2
L
L1

40

12

D1
D2
D4

20

B1
B

0
0
0

B2

50

100

10

12

150

14

0
Q m3/h

200

Q l/s

250 Q l/min

The performance curves are based on kinematic viscosity values =


1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906.

MODEL

CENTRE
DISTANCE
mm

POWER INPUT
50 Hz

UNIONS ON
REQUEST

250

1x230 V ~

DN 40 - PN 10

WET ROTOR CIRCULATORS

D56/250.40 M

MODEL
D56/250.40 M

SPEED

REV.
1/min

3
2
1

2658
2117
1394

ELECTRICAL DATA
P1 MAX
In
W
A
271
294
224

MINIMUM SUCTION PRESSURE


CAPACITOR
F
Vc

1,18
1,32
1,00

400

90

m.c.a.

1,5

PACKING DIMENSIONS

L1

L2

B1

B2

D1

D2

D3

D4

H1

H2

250

125

125

204

65

139

150

110

100

80

40

247

122

126

DN40/PN10

355

298

283

VOLUME
m3

WEIGHT
kg

0,018

15,8

D56/250.40 T - HEATING, AIR CONDITIONING

Pumped liquid temperature range: from -10 C to +110 C - Maximum operating pressure: 10 bar (1000 kPa)
H1

H2

D
D3

10
10
0,5

20
1

30
20

40
30

1,5

50

60

40
2,5

Q USgpm

50
3

Q IMPgpm
V m/s 1"
H
400 V~ 50 Hz ft

P
kPa

H
m

60

20

16

L2
L
L1

40

12

D1
D2
D4

20

B1
B

0
0
0

B2

50

100

10
150

12

14

200

0
Q m3/h

Q l/s

250 Q l/min

The performance curves are based on kinematic viscosity values =


1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906.

MODEL

CENTRE
DISTANCE
mm

POWER INPUT
50 Hz

UNIONS ON
REQUEST

250

3x400 V ~

DN 40 - PN 10

D56/250.40 T

MODEL
D56/250.40 T

SPEED
2

2708

291

0,60

2178

200

0,33

MINIMUM SUCTION PRESSURE


CAPACITOR
F
Vc

L1

L2

B1

B2

D1

D2

D3

D4

H1

H2

250

125

125

204

65

139

150

110

100

80

40

247

122

126

DN40/PN10

DAB PUMPS reserves the right to make modifications without notice.

136

ELECTRICAL DATA
P1 MAX
In
W
A

REV.
1/min

PACKING DIMENSIONS
L

335

298

283

90

m.c.a.

1,5

VOLUME
m3

WEIGHT
kg

0,018

15,4

D80/250.40 M - HEATING, AIR CONDITIONING

Pumped liquid temperature range: from -10 C to +110 C - Maximum operating pressure: 10 bar (1000 kPa)
H1

H2

D
D3

10
5

0,5

15
10

20
15

25

30

20

35

25
1,5

40

30

45
35

Q USgpm

40 Q IMPgpm
V m/s 1"
H
230 V~ 50 Hz ft

P
kPa

H
m
8

70

60

20

50

16

40

30

20

10

L2
L
L1

D1
D2
D4
B1
B

0
0

24

12
8
4
0

B2

0,5

20

40

60

1,5

80

100

120

10

2,5
140

11

160

0
Q m3/h

Q l/s

180

Q l/min

The performance curves are based on kinematic viscosity values =


1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906.

CENTRE
DISTANCE
mm

POWER INPUT
50 Hz

UNIONS ON
REQUEST

250

1x230 V ~

DN 40 - PN 10

D80/250.40 M

MODEL
D80/250.40 M

SPEED

REV.
1/min

3
2
1

2683
2374
1688

ELECTRICAL DATA
P1 MAX
In
W
A
256
260
218

MINIMUM SUCTION PRESSURE


CAPACITOR
F
Vc

1,12
1,17
1,00

400

90

m.c.a.

2,5

PACKING DIMENSIONS

L1

L2

B1

B2

D1

D2

D3

D4

H1

H2

250

125

125

204

65

139

150

110

100

80

40

247

122

126

DN40/PN10

355

298

283

VOLUME
m3

WEIGHT
kg

0,018

15,8

D80/250.40 T - HEATING, AIR CONDITIONING

Pumped liquid temperature range: from -10 C to +110 C - Maximum operating pressure: 10 bar (1000 kPa)
H1

H2

D
D3

10
5

0,5

15
10

20
15

25

30

20

35

25
1,5

40

30

45
35

Q USgpm

40 Q IMPgpm
V m/s 1"
H
400 V~ 50 Hz ft

P
kPa

H
m
8

70

60

20

50

16

40

30

20

10

L2
L
L1

D1
D2
D4
B1
B

0
0

24

12
8
4
0

B2

0,5

20

40

60

1,5

80

100

120

2,5
140

10

11

160

180

0
Q m3/h

Q l/s

Q l/min

The performance curves are based on kinematic viscosity values =


1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906.

MODEL

CENTRE
DISTANCE
mm

POWER INPUT
50 Hz

UNIONS ON
REQUEST

250

3x400 V ~

DN 40 - PN 10

D80/250.40 T

MODEL
D80/250.40 T

ELECTRICAL DATA
P1 MAX
In
W
A

SPEED

REV.
1/min

2724

271

0,57

2226

187

0,31

MINIMUM SUCTION PRESSURE


CAPACITOR
F
Vc

L1

L2

B1

B2

D1

D2

D3

D4

H1

H2

250

125

125

204

65

139

150

110

100

80

40

247

122

126

DN40/PN10

PACKING DIMENSIONS
L

335

298

283

90

m.c.a.

2,5

VOLUME
m3

WEIGHT
kg

0,018

15,8

DAB PUMPS reserves the right to make modifications without notice.

137

WET ROTOR CIRCULATORS

MODEL

D110/250.40 M - HEATING, AIR CONDITIONING

Pumped liquid temperature range: from -10 C to +110 C - Maximum operating pressure: 10 bar (1000 kPa)
H
H2

D D3
L2

P
kPa

H2

10

90

80

70

60

50

40

30

20

10

H1

L1

B1

D1
D2
D4
D1
D2
D4

20

40

20
0,8

50

30
1,2

40
1,6

Q USgpm
Q IMPgpm
V m/s 1"1/2
H
230 V~ 50 Hz ft
30
25
20

B1

B2

15
10
5

B1
B

0,5

B2
B

20

1
40

60

1,5
80

10

2
100

2,5

120

140

12

Q m3/h

3
160

180

3,5
200

Q l/s
220 Q l/min

B2

The performance curves are based on kinematic viscosity values =


1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906.

MODEL

CENTRE
DISTANCE
mm

POWER INPUT
50 Hz

UNIONS ON
REQUEST

250

1x230 V ~

DN 40 - PN 10

D110/250.40 M

L
L2

MODEL
L1

SPEED

REV.
1/min

3
2
1

2746
2552
2052

ELECTRICAL DATA
P1 MAX
In
W
A
410
393
361

MINIMUM SUCTION PRESSURE


CAPACITOR
F
Vc

1,77
1,78
1,64

12

L1

L2

B1

B2

D1

D2

D3

D4

H1

H2

250

122

128

231

70

161

150

110

100

80

40

302

149

154

DN40/PN10

355

298

283

L2

D110/250.40 M

450

90

m.c.a.

2,5

PACKING DIMENSIONS

L
L1

VOLUME
m3

WEIGHT
kg

0,018

16

D110/250.40 T - HEATING, AIR CONDITIONING

Pumped liquid temperature range: from -10 C to +110 C - Maximum operating pressure: 10 bar (1000 kPa)
H
H
H2

H1

D D3 D D3

H2

H1

D D3

400 V~ 50 Hz
L2

H2
H

D1
D2
D4

WET ROTOR CIRCULATORS

30

10
0,4

11

100

10

0
H0
m

D1
D2
D4

H
H1

D D3 D D3

H2

H1

H1

L1

B1

B1

D1
D2
D4
D1
D2
D4

B2

B1
B
B2
B
B2

The performance curves are based on kinematic viscosity values =


1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906.

MODEL

CENTRE
DISTANCE
mm

POWER INPUT
50 Hz

UNIONS ON
REQUEST

250

3x400 V ~

DN 40 - PN 10

D110/250.40 T

MODEL
D110/250.40 T

SPEED
2

2759

403

0,90

2341

289

0,48

MINIMUM SUCTION PRESSURE


CAPACITOR
F
Vc

L1

L2

B1

B2

D1

D2

D3

D4

H1

H2

250

122

128

231

70

161

150

110

100

80

40

302

149

154

DN40/PN10

DAB PUMPS reserves the right to make modifications without notice.

138

ELECTRICAL DATA
P1 MAX
In
W
A

REV.
1/min

PACKING DIMENSIONS
L

355

298

283

90

m.c.a.

2,5

VOLUME
m3

WEIGHT
kg

0,018

15,8