HEXAGONE

Industrial Power for

Business-Critical Continuity

DC Back-up Power System

Hexagone is a battery charger

dedicated to protect DC critical

industrial equipments and processes

from the damaging effects of power

interruptions and losses.

Benefits

Shorten lead time to meet project

schedules

Easy parameter settings for quick on-site

adjustments

Easy maintenance via direct access to

components from front to reduce MTTR

Key Features

High reliability provided by a fully controlled

6-pulse SCR bridge and a reduced quantity of

components

Low Ripple Voltage to enhance battery life

Low inrush current < 8In not to oversize

mains power supply

Human-Machine Interface (HMI) choice to

deliver the user with appropriate information

level

Fault prediction to anticipate potential

failures

Ingress protection up to IP55 for harsh

environmental conditions

Compatibility with Nickel-Cadmium and Lead

batteries, open or gas-recombination types

Galvanic isolation between input and output

Digital control and monitoring

A wide choice of configurations and options

Applications

01

A13M429-PEL003-086

O/C:

4501464804

PEL003

GESTION

SEG

Proyecto

A13M429

Hexagone suits all DC applications requiring a

large battery back-up:

Power Transmission and Distribution

Continuous process industries

Petrochemical and Chemical industries

Water treatment

Marine

Military

Hexagone is available as standard from 35A to 400A in a wide range of output

voltages, from 24 Vdc to 220 Vdc. It is suitable for use either as a battery charger,

rectifier or as a DC power supply.

Hexagone features a microprocessor control which offers exceptional stability

and allows adaptability for different application requirements. In order to

improve load availability and process reliability, Hexagone is able to operate

in dual parallel configuration.

Este documento ya fue comentado. NO se requiere de nueva revision.

CERTIFICADO
ABB S.A.
01 02 2016

HEXAGONE

Industrial Power for

Business-Critical Continuity

DC Back-up Power System

Ratings (A)
24 VDC output voltage
48 VDC output voltage
110 / 125 VDC output voltage
220 VDC output voltage

35

65

1 00

1 60

220

300

400

This publication is issued to provide outline information only and is not deemed to form any part of any offer and/or contract. The company has a policy of continuous product development and improvement, and we therefore reserve the right to vary
any information without prior notice.

Hexagone-DSUK-Rev0-06/201 1

Technical Specification

Input

Three-phase voltage / tolerance


Frequency range
Inrush current
Power factor

380 - 400 - 415 / +/-10% (other voltage on request)

From 47 to 63 Hz

< 8In

0.8

Output

Nominal DC voltage
Available ratings
Static regulation
Ripple voltage (disconnected battery)
Float voltage
Charge voltage
Equalization voltage

24, 48, 110, 125, 220 VDC (other upon request)

See table above

0.5%

< 0.7%

From 0.70 Un to 1.47 Un

From 0.73 Un to 1.60 Un

From 0.83 Un to 1.70 Un

Battery

Type
Autonomy

Lead Acid or Nickel Cadmium, vented or recombination type

From few minutes to several hours, as per customer's requirement

General data

AC/DC efficiency
Operating temperature
Storage temperature
Relative humidity
Operating altitude
Cooling
External ingress protection
Noise
Input / output isolation
Frame colour
Dimensions

From 83% to 94% (according to model)

From 0 to 45C

From -20 to +70C (battery excluded)

< 95% non condensing at 20C

1000m (without system derating)

Fan-assisted

IP 20

< 60 dB

2500 VAC / 1 minute

RAL 7035

Varying according to ratings and options (please consult us)

Options

Charger

Battery

Mechanical

Load

Coupling diode

Dropping diode

DC earth fault monitor

Ultra low ripple voltage < 0.1%

Isolated communication interface, RS 485, Modbus protocol

Front panel LEDs status annunciator

Protection against battery reversed polarity

Battery Low Voltage Disconnect (LVD)

Integrated batteries (on shelves or drawers)

Temperature sensor for battery charge compensation

External ingress protection IP21, 23, 41, 43, 55

Natural cooling

Space heater

Input / output terminal wiring

Internal protection against electric contacts with open door

Internal lighting, lifting eyes


Distribution board (circuit breaker with or without contact)

Standards

Compliance

Emerson Network Power.

The global leader in enabling

Business-Critical Continuity.

EMC n2004/108/CE - NF EN 61000-6-2 - NF EN 61000-6-4

LVD n2006/95/CE - NF EN 60439-1

NFC 58-311

IEC 60146

AC Power

Connectivity

DC Power

Embedded Computing

Emerson Network Power

Chloride France S.A.

30 avenue Montgolfier - BP90 - 69684 Chassieu Cedex France

T +33 (0) 4 78 40 13 56 - F +33 (0) 4 78 90 58 90

E industrial.sales.chloride@emerson.com

EmersonNetworkPower.com

Embedded Power

Industrial Power

Infrastructure Management & Monitoring

Outside Plant

Power Switching & Controls

Precision Cooling

Racks & Integrated Cabinets

Services

Emerson, Business-Critical Continuity and

Emerson Network Power are trademarks of

Emerson Electric Co. or one of its affiliated companies.

2011 Emerson Electric Co.

E-0000 000

Das könnte Ihnen auch gefallen