Type No.
Protocols
Logical interface ex factory 1)
Input voltage range
Power consumption
Connectors 2) 3)
Hardware interfaces
Housing material
Weight
Packing size
Dimensions (H x W x D)
1)
The protocol of the logical interface can be switched from 3GPP/AISG 2.0 AISG 1.1 to with a vendor
specific command. Start-up operation of the RCU is only possible in a RET system supporting 3GPP/
AISG 2.0!
The protocol can also be changed as follows: 3GPP to AISG 1.1: Enter AISG1 into the additional data
field Installers ID and perform a layer 2 reset or a power reset. AISG 1.1 to 3 GPP: Enter 3GPP into
the additional data filed Installers ID and perform a layer 7 reset or a power reset. After switching the
protocol any other information can be entered into the Installers ID field.
Please note:
If the Primary of the RET system doesnt support the standard of the logical interface ex factory, the RCU
must be switched to the appropriate standard of the Primary before installation. Please contact Kathrein
for further information.
Daisy chain in
(male)
2)
The tightening torque for fixing the connector must be 0.5 1.0 Nm (hand-tightened). The connector
should be tightened by hand or using the torque screwdriver (85010080) as described in the connecting
cable data sheet (85010007, ...)
3)
The RCU gets the information stored in the antenna after power on automatically if a corresponding
antenna is used. It is not necessary to configurate the RCU manually.
EN 60950-1 (Safety)
EN 60950-22 (Safety Equipment installed outdoor)
EN 55022 (Emission)
EN 55024 (Immunity)
ETS 300019-1-4 (Environmental)
UL 60950-1; 1st edition
Scope of supply:
173.6 mm
(6.8)
8 mm
(0.31)
www.kathrein.de
46 mm
( 1.8)
49.5 mm
(1.95)
59.5 mm
(2.34)
CE, FCC
28.5 mm
(1.1)
Certification:
M42x1.5
936.4624/a
Subject to alteration.
Standards:
33.2 mm
(1.27)
86010148V01 Page 1 of 5
KATHREIN-Werke KG Anton-Kathrein-Strae 1-3 P.O. Box 10 04 44 83004 ROSENHEIM GERMANY Phone +49 8031 184-0 Fax +49 8031 184-820
Please note:
Additional grounding of the RCU is not required if the RCU is fixed to an antenna with proper grounding. Please assure that grounding of the antenna has been carried out according to all relevant local
regulations.
Please note:
As a result of more stringent legal regulations and judgements regarding product liability, we are
obliged to point out certain risks that may arise when products are used under extraordinary operating
conditions.
The mechanical design is based on the environmental conditions as stipulated in ETS 300 019-1-4 and thereby
respects the static mechanical load imposed on an antenna by wind at maximum velocity. Wind loads are
calculated according to DIN 1055-4. Extraordinary operating conditions, such as heavy icing or exceptional
dynamic stress (e.g. strain caused by oscillating support structures), may result in the breakage of an antenna or
even cause it to fall to the ground. These facts must be considered during the site planning process.
The installation team must be properly qualified and also be familiar with the relevant national safety
regulations.
The details given in our data sheets have to be followed carefully when installing the antennas and
accessories.
The limits for the coupling torque of RF-connectors, recommended by the connector manufacturers must
be obeyed.
Any previous datasheet issues have now become invalid.
2
2
To set the downtilt angle exactly,
you must look horizontally at the
scale. The lower edge of the gearwheel must be used for alignment.
Subject to alteration.
936.4624/a
Page 2 of 5 86010148V01
www.kathrein.de
KATHREIN-Werke KG Anton-Kathrein-Strae 1-3 P.O. Box 10 04 44 83004 ROSENHEIM GERMANY Phone +49 8031 184-0 Fax +49 8031 184-820
Attaching the RCU (Remote Control Unit) for remote-controlled downtilt adjustment:
936.4624/a
Subject to alteration.
www.kathrein.de
86010148V01 Page 3 of 5
KATHREIN-Werke KG Anton-Kathrein-Strae 1-3 P.O. Box 10 04 44 83004 ROSENHEIM GERMANY Phone +49 8031 184-0 Fax +49 8031 184-820
FCC Statements
FCC Statements
FCC 15.19
This device complies with Part 15 of the FCC rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
FCC 15.105
Note: This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or more of the following
measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
Consult the dealer or an experienced radio/TV technician for help.
Canada CNR-Gen Section 7.1.3
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to
the following two conditions:(1) this device may not cause interference, and (2) this device must
accept any interference, including interference that may cause undesired operation of the device.
Subject to alteration.
Le prsent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio
exempts de licence. L'exploitation est autorise aux deux conditions suivantes : (1) l'appareil ne
doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage
radiolectrique subi, mme si le brouillage est susceptible d'en compromettre le fonctionnement.
ICES-003
This Class B digital apparatus complies with Canadian ICES-003.
936.4624/a
www.kathrein.de
KATHREIN-Werke KG Anton-Kathrein-Strae 1-3 P.O. Box 10 04 44 83004 ROSENHEIM GERMANY Phone +49 8031 184-0 Fax +49 8031 184-820
FCC Statements
936.4624/a
Subject to alteration.
www.kathrein.de
86010148V01 Page 5 of 5
KATHREIN-Werke KG Anton-Kathrein-Strae 1-3 P.O. Box 10 04 44 83004 ROSENHEIM GERMANY Phone +49 8031 184-0 Fax +49 8031 184-820