MA PA DE PELIGROS, PLA N DE USOS DEL SUELO ANTE DESASTRES Y MEDIDAS DE MITIGACIN DE EL TA MBO, HUANCAYO Y CHILCA
ANALISIS GRANULOMETRICO
Ttulo:
Fecha de revisin:
15-feb-11
CAL./muestra
Proyecto:
ESTUDIO DE MAPA DE PELIGROS Y PLAN DE USO DE SUELOS ANTE DESASTRES Y MEDIDAS DE MITIGACION DE LA CIUDADES DE
HUANCAYO, EL TAMBO Y CHILCA
Contratante
M U N IC IP A LID A D P R OV IN C IA L D E H U A N C A Y O
Sondaje
S1
Profundidad:
T am ao
Tamiz
2.00
Mt.
Pes o R eten.
Ac umulado
%
R etenido
%
Pas a
07/02/2011
IN SITU
1.00
Especif ic.
Ubicacin
HUANCAYO
8"
0.0
0.00%
100.00%
6"
0.0
0.00%
100.00%
4"
0.0
0.00%
100.00%
3"
0.0
0.00%
100.00%
2"
0.0
0.00%
100.00%
114.0
18.51%
81.49%
1"
0.0
0.00%
81.49%
3/4"
0.0
0.00%
81.49%
BANDEJA
428.0
3/8"
80.0
12.99%
68.51%
1122.0
1 1/2"
No. 4
60.0
9.74%
58.77%
1044.0
No. 10
58.0
9.42%
49.35%
880.0
No. 20
36.0
5.84%
43.51%
616.0
No. 40
46.0
7.47%
36.04%
No. 60
24.0
3.90%
32.14%
No. 100
22.0
3.57%
28.57%
12.0
1.95%
26.62%
164.0
26.62%
0.00%
No. 200
Platillo
LL =
18
0.1
0.1
0.2
0.4
0.3
0.9
1.2
0.6
2.0
4.8
2.4
9.5
12.7
19.0
25.4
Tamao en mm
17
GM
IP =
D 10 =
D 30 =
D 60 =
A-2-4 ( 0 )
COLOR:
12.66%
MARRON
26.62%
68.5 1
70
No. Tara
60
No. Tara
0.1560
112.2
1122.0
104.4
880.0
Peso de Tara
42.8
Peso de Tara
428.0
7.8
242.0
Peso Seco
61.6
452.0
12.66%
26.62%
49.35
58.77
50
43.51
40
28.57
0.0780
30
26.6 2
32.14
36.04
0.026
0.078
0.156
Contenido de humedad de la f raccin de Suelo seco que pasa % de suelo seco que pasa la malla No. 200
la malla # 4 :
:
81.49
81.49
81.49
101.6
76.2
50.8
PROCEDENCIA:
37.5
90
203.2
CLASIF.(SUCS/
ASHTOO):
152.4
100
80
LP =
Cc= 1.50
Cu= 6.00
20
0.0260
10
0 . 1
1.00
No.200
No.140
No.100
N o.60
N o.40
N o.30
1 . 0
N o.20
N o.16
N o.8
N o.10
3/8"
3/4"
1"
OBSERVACIONES :
0 . 0
1
N o.4
TAMIZ
1/2"
2"
3"
1 0 0 . 0
1 1/2"
8"
4"
1 0 0 0 .0
6"
Cont. de humedad %
0
0 . 0
Las gra vas mayore s a la N 4, de acuerdo a l mue streo en campo, e s de a proxima dame nte
EJECUTO
REVISO
APROBO
Vo. Bo.
LAB ORATORISTA
41.23%
RESULTADO
CUMPLE
FECHA:
12/02/2011
FECHA :
13/02/2011
FECHA :
14/02/2011
FECHA:
15-feb
SI
CUMPLE
SI
FECHA:
15-feb
MA PA DE PELIGROS, PLA N DE USOS DEL SUELO ANTE DESASTRES Y MEDIDAS DE MITIGACIN DE EL TA MBO, HUANCAYO Y CHILCA
ANALISIS GRANULOMETRICO
Ttulo:
Fecha de revisin:
15-feb-11
CAL./muestra
Proyecto:
ESTUDIO DE MAPA DE PELIGROS Y PLAN DE USO DE SUELOS ANTE DESASTRES Y MEDIDAS DE MITIGACION DE LA CIUDADES DE
HUANCAYO, EL TAMBO Y CHILCA
Contratante
M U N IC IP A LID A D P R OV IN C IA L D E H U A N C A Y O
Sondaje
S1
Profundidad:
3.00
T am ao
Tamiz
Mt.
Pes o R eten.
Ac umulado
07/02/2011
IN SITU
2.00
Ubicacin
HUANCAYO
%
R etenido
%
Pas a
8"
0.0
0.00%
100.00%
6"
0.0
0.00%
100.00%
4"
0.0
0.00%
100.00%
3"
0.0
0.00%
100.00%
2"
0.0
0.00%
100.00%
210.0
24.59%
75.41%
0.0
0.00%
75.41%
3/4"
232.0
27.17%
48.24%
BANDEJA
424.0
3/8"
212.0
24.82%
23.42%
1304.0
1 1/2"
1"
Especif ic.
No. 4
12.0
1.41%
22.01%
1278.0
No. 10
8.0
0.94%
21.08%
1266.0
No. 20
10.0
1.17%
19.91%
854.0
No. 40
80.0
9.37%
10.54%
No. 60
50.0
5.85%
4.68%
No. 100
14.0
1.64%
3.04%
No. 200
6.0
0.70%
2.34%
Platillo
20.0
2.34%
0.00%
LL =
0.1
0.1
0.2
0.4
0.3
0.9
1.2
0.6
2.0
4.8
2.4
9.5
12.7
19.0
25.4
76.2
101.6
PROCEDENCIA:
50.8
90
37.5
CLASIF.(SUCS/
ASHTOO):
203.2
100
152.4
LP =
Cc= 1.50
Cu= 6.00
Tamao en mm
GP
IP =
D 10 =
D 30 =
D 60 =
A-1-a(0)
COLOR:
0.496
1.489
2.978
MARRON
Contenido de humedad de la f raccin de Suelo seco que pasa % de suelo seco que pasa la malla No. 200
la malla # 4 :
:
75.41
75.41
80
3.04%
2.34%
No. Tara
No. Tara
2.9778
60
50
130.4
1304.0
127.8
1266.0
Peso de Tara
42.4
Peso de Tara
424.0
2.6
38.0
Peso Seco
85.4
842.0
3.04%
2.34%
48.2 4
40
1.4889
19.91
0 . 1
Cont. de humedad %
1.0 0
4.68
3.04
N o.140
N o.100
N o.60
N o.40
N o.30
1 . 0
N o.20
N o.16
N o.8
N o.10
3/8"
3/4"
1"
OBSERVACIONES :
0 . 0
1
No.4
TAMIZ
1/2"
2"
3"
1 0 0 . 0
1 1/2"
8"
4"
1 0 0 0 .0
6"
2.34
0.4963
10
N o.200
20
10.54
22.01
23.42
30
21.08
70
0 . 0
Las gra vas mayore s a la N 4, de acuerdo a l mue streo en campo, e s de a proxima dame nte
EJECUTO
REVISO
APROBO
Vo. Bo.
LAB ORATORISTA
77.99%
RESULTADO
CUMPLE
FECHA:
12/02/2011
FECHA :
13/02/2011
FECHA :
14/02/2011
FECHA:
15-feb
SI
CUMPLE
SI
FECHA:
15-feb
MA PA DE PELIGROS, PLA N DE USOS DEL SUELO ANTE DESASTRES Y MEDIDAS DE MITIGACIN DE EL TA MBO, HUANCAYO Y CHILCA
ANALISIS GRANULOMETRICO
Ttulo:
Fecha de revisin:
15-feb-11
CAL./muestra
Proyecto:
ESTUDIO DE MAPA DE PELIGROS Y PLAN DE USO DE SUELOS ANTE DESASTRES Y MEDIDAS DE MITIGACION DE LA CIUDADES DE
HUANCAYO, EL TAMBO Y CHILCA
Contratante
M U N IC IP A LID A D P R OV IN C IA L D E H U A N C A Y O
Sondaje
S2
Profundidad:
T am ao
Tamiz
2.00
Mt.
Pes o R eten.
Ac umulado
%
R etenido
%
Pas a
07/02/2011
IN SITU
1.00
Especif ic.
Ubicacin
HUANCAYO
8"
0.0
0.00%
100.00%
6"
0.0
0.00%
100.00%
4"
0.0
0.00%
100.00%
3"
0.0
0.00%
100.00%
2"
0.0
0.00%
100.00%
1 1/2"
0.0
0.00%
100.00%
1"
0.0
0.00%
100.00%
3/4"
232.0
35.26%
64.74%
BANDEJA
432.0
3/8"
86.0
13.07%
51.67%
1114.0
82.0
12.46%
7.90%
No. 60
20.0
3.04%
4.86%
No. 100
8.0
1.22%
3.65%
No. 200
4.0
0.61%
3.04%
Platillo
20.0
3.04%
0.00%
100
LL =
LP =
0.1
0.1
CLASIF.(SUCS/
ASHTOO):
Tamao en mm
GP
IP =
D 10 =
D 30 =
D 60 =
Cc= 1.50
Cu= 6.00
0.2
0.3
1.2
0.6
2.0
2.4
9.5
0.4
658.0
No. 40
0.9
4.8
20.36%
12.7
11.55%
100.019.0
0
76.0
100.025.4
0
1078.0
No. 20
101.6
1090.0
76.2
31.91%
50.8
42.86%
10.94%
37.5
8.81%
72.0
203.2
58.0
152.4
No. 4
No. 10
A-1-b(0)
COLOR:
0.327
0.980
1.959
MARRON
PROCEDENCIA:
90
Contenido de humedad de la f raccin de Suelo seco que pasa % de suelo seco que pasa la malla No. 200
la malla # 4 :
:
80
3.65%
3.04%
64.74
No. Tara
No. Tara
1.9 593
60
51.67
50
42.86
111.4
1114.0
109.0
1078.0
Peso de Tara
43.2
Peso de Tara
432.0
2.4
36.0
Peso Seco
65.8
646.0
3.65%
3.04%
40
31.91
0.9796
20.36
30
20
0.3265
0 . 1
Cont. de humedad %
1.00
3.04
3.65
No.140
No.100
N o.60
N o.40
N o.30
1 . 0
N o.20
N o.16
N o.8
N o.10
3/8"
3/4"
1"
OBSERVACIONES :
0 . 0
1
N o.4
TAMIZ
1/2"
2"
3"
1 0 0 . 0
1 1/2"
8"
1 0 0 0 .0
4"
6"
4.86
7.90
10
No.200
70
0 . 0
Las gra vas mayore s a la N 4, de acuerdo a l mue streo en campo, e s de a proxima dame nte
EJECUTO
REVISO
APROBO
Vo. Bo.
LAB ORATORISTA
57.14%
RESULTADO
CUMPLE
FECHA:
12/02/2011
FECHA :
13/02/2011
FECHA :
14/02/2011
FECHA:
15-feb
SI
CUMPLE
SI
FECHA:
15-feb
MA PA DE PELIGROS, PLA N DE USOS DEL SUELO ANTE DESASTRES Y MEDIDAS DE MITIGACIN DE EL TA MBO, HUANCAYO Y CHILCA
ANALISIS GRANULOMETRICO
Ttulo:
Fecha de revisin:
15-feb-11
CAL./muestra
Proyecto:
ESTUDIO DE MAPA DE PELIGROS Y PLAN DE USO DE SUELOS ANTE DESASTRES Y MEDIDAS DE MITIGACION DE LA CIUDADES DE
HUANCAYO, EL TAMBO Y CHILCA
Contratante
M U N IC IP A LID A D P R OV IN C IA L D E H U A N C A Y O
Sondaje
S2
Profundidad:
T am ao
Tamiz
3.00
Mt.
Pes o R eten.
Ac umulado
%
R etenido
%
Pas a
07/02/2011
IN SITU
2.00
Especif ic.
HUANCAYO
8"
0.0
0.00%
100.00%
6"
0.0
0.00%
100.00%
4"
0.0
0.00%
100.00%
3"
0.0
0.00%
100.00%
2"
0.0
0.00%
100.00%
1 1/2"
0.0
0.00%
100.00%
1"
0.0
0.00%
100.00%
3/4"
232.0
30.13%
69.87%
BANDEJA
426.0
3/8"
180.0
23.38%
46.49%
1218.0
9.87%
12.47%
No. 60
30.0
3.90%
8.57%
No. 100
18.0
2.34%
6.23%
No. 200
8.0
1.04%
5.19%
Platillo
40.0
5.19%
0.00%
LL =
LP =
0.1
0.1
CLASIF.(SUCS/
ASHTOO):
Tamao en mm
GP-GM
IP =
D 10 =
D 30 =
D 60 =
Cc= 1.50
Cu= 6.00
0.2
0.3
1.2
0.6
2.4
9.5
0.4
76.0
0.9
770.0
No. 40
2.0
4.8
22.34%
12.7
6.49%
100.019.0
0
50.0
100.025.4
0
1156.0
No. 20
101.6
1196.0
76.2
28.83%
50.8
37.92%
9.09%
37.5
8.57%
70.0
203.2
66.0
152.4
No. 4
No. 10
100
A-1-b(0)
COLOR:
0.159
0.476
0.953
MARRON
PROCEDENCIA:
90
Contenido de humedad de la f raccin de Suelo seco que pasa % de suelo seco que pasa la malla No. 200
la malla # 4 :
:
80
2.86%
69.87
70
No. Tara
5.19%
1
No. Tara
0.9 526
60
121.8
1218.0
119.6
1156.0
Peso de Tara
42.6
Peso de Tara
426.0
2.2
62.0
Peso Seco
77.0
730.0
2.86%
5.19%
50
46.49
40
37.92
Ubicacin
0.4763
22.34
28.8 3
30
Cont. de humedad %
1.00
5.19
6.23
0 . 1
No.200
No.140
No.100
N o.40
N o.30
1 . 0
N o.20
N o.16
N o.8
N o.10
3/8"
3/4"
1"
OBSERVACIONES :
0 . 0
1
N o.4
TAMIZ
1/2"
2"
3"
1 0 0 . 0
1 1/2"
8"
4"
1 0 0 0 .0
6"
N o.60
0.1588
10
8.57
12.47
20
0 . 0
Las gra vas mayore s a la N 4, de acuerdo a l mue streo en campo, e s de a proxima dame nte
EJECUTO
REVISO
APROBO
Vo. Bo.
LAB ORATORISTA
62.08%
RESULTADO
CUMPLE
FECHA:
12/02/2011
FECHA :
13/02/2011
FECHA :
14/02/2011
FECHA:
15-feb
SI
CUMPLE
SI
FECHA:
15-feb
MA PA DE PELIGROS, PLA N DE USOS DEL SUELO ANTE DESASTRES Y MEDIDAS DE MITIGACIN DE EL TA MBO, HUANCAYO Y CHILCA
ANALISIS GRANULOMETRICO
Ttulo:
Fecha de revisin:
15-feb-11
CAL./mues tra
Proyecto:
ESTUDIO DE MAPA DE PELIGROS Y PLAN DE USO DE SUELOS ANTE DESASTRES Y MEDIDAS DE MITIGACION DE LA CIUDADES DE
HUANCAYO, EL TAMBO Y CHILCA
Contratante
M U N IC IP A L ID A D P R O VIN C IA L D E H UA N C A Y O
Sondaje
S3
Profundidad:
2.00
Mt.
Peso Reten.
Ac um ulado
%
Retenido
%
Pas a
T amao
Tamiz
Fecha muestreo:
07/02/2011
IN SITU
1.00
Especif ic .
Ubicacin
HUANCAYO
8"
0.0
0.00%
100.00%
6"
0.0
0.00%
100.00%
4"
0.0
0.00%
100.00%
3"
0.0
0.00%
100.00%
2"
0.0
0.00%
100.00%
396.0
56.90%
43.10%
0.0
0.00%
43.10%
3/4"
114.0
16.38%
26.72%
BANDEJA
3/8"
58.0
8.33%
18.39%
1142.0
1 1/2"
1"
422.0
No. 4
38.0
5.46%
12.93%
1118.0
No. 10
20.0
2.87%
10.06%
1102.0
No. 20
22.0
3.16%
6.90%
No. 40
10.0
1.44%
5.46%
No. 60
8.0
1.15%
4.31%
No. 100
0.0
0.00%
4.31%
2.0
0.29%
4.02%
28.0
4.02%
0.00%
No. 200
Platillo
LL =
0.1
0.1
0.2
0.4
0.3
0.9
1.2
0.6
2.0
4.8
2.4
9.5
12.7
19.0
25.4
101.6
76.2
PROCEDENCIA:
50.8
90
37.5
CLASIF.(SUCS/
ASHTOO):
203.2
LP =
Cc= 1.50
Cu= 6.00
100
152.4
696.0
Tamao en mm
GP
IP =
D 10 =
D 30 =
D 60 =
COLOR:
A-1-b(0)
0.220
0.661
1.322
MARRON
Contenido de humedad de la f raccin de Suelo seco que pasa % de suelo seco que pasa la malla No. 200
la malla # 4 :
:
80
3.45%
4.02%
No. Tara
No. Tara
1.3219
60
114.2
1142.0
111.8
1102.0
Peso de Tara
42.2
Peso de Tara
422.0
2.4
40.0
Peso Seco
69.6
680.0
Cont. de humedad %
3.45%
4.02%
43.10
50
43.10
70
40
0.6609
26.72
30
10.0 6
OBSERVACIONES :
1.00
4.02
4.31
N o.140
N o.100
0 . 1
N o.200
5.46
N o.40
N o.30
1 . 0
N o.20
N o.16
N o.8
N o.10
3/8"
3/4"
1"
1 0 . 0
N o.4
TAMIZ
1/2"
2"
3"
1 0 0 .0
1 1/2"
4"
8"
1 0 0 . 0
6"
4.31
0.2203
6.90
10
N o.60
12.93
18.39
20
0 . 0
EJECUTO
REVISO
APROBO
Vo. Bo.
LA BORA TORISTA
ROAD TECH SA C
87.07%
RESULTADO
CUMPLE
FECHA:
12/02/2011
FECHA:
13/02/2011
FECHA:
14/02/2011
FECHA :
15-feb
SI
CUMPLE
SI
FECHA :
15-feb
MA PA DE PELIGROS, PLA N DE USOS DEL SUELO ANTE DESASTRES Y MEDIDAS DE MITIGACIN DE EL TA MBO, HUANCAYO Y CHILCA
ANALISIS GRANULOMETRICO
Ttulo:
Fecha de revisin:
15-feb-11
CAL./muestra
Proyecto:
ESTUDIO DE MAPA DE PELIGROS Y PLAN DE USO DE SUELOS ANTE DESASTRES Y MEDIDAS DE MITIGACION DE LA CIUDADES DE
HUANCAYO, EL TAMBO Y CHILCA
Contratante
M U N IC IP A LID A D P R OV IN C IA L D E H U A N C A Y O
Sondaje
S3
Profundidad:
T am ao
Tamiz
3.00
Mt.
Pes o R eten.
Ac umulado
%
R etenido
%
Pas a
07/02/2011
IN SITU
2.00
Especif ic.
Ubicacin
HUANCAYO
8"
0.0
0.00%
100.00%
6"
0.0
0.00%
100.00%
4"
0.0
0.00%
100.00%
3"
0.0
0.00%
100.00%
2"
0.0
0.00%
100.00%
114.0
14.69%
85.31%
0.0
0.00%
85.31%
3/4"
132.0
17.01%
68.30%
BANDEJA
434.0
3/8"
76.0
9.79%
58.51%
1242.0
1 1/2"
1"
No. 4
60.0
7.73%
50.77%
1210.0
No. 10
80.0
10.31%
40.46%
1136.0
No. 20
72.0
9.28%
31.19%
776.0
No. 40
74.0
9.54%
21.65%
No. 60
32.0
4.12%
17.53%
No. 100
22.0
2.84%
14.69%
No. 200
16.0
2.06%
12.63%
Platillo
98.0
12.63%
0.00%
LL =
0.1
0.1
0.2
0.4
0.3
0.9
1.2
0.6
2.0
4.8
2.4
9.5
12.7
19.0
25.4
Tamao en mm
85.31
85.31
101.6
76.2
PROCEDENCIA:
50.8
90
37.5
CLASIF.(SUCS/
ASHTOO):
203.2
100
152.4
LP =
GM
IP =
D 10 =
D 30 =
D 60 =
Cc= 1.50
Cu= 6.00
A-1-b ( 0 )
COLOR:
4.12%
12.63%
68.30
No. Tara
60
No. Tara
0.3436
50.77
58.51
50
124.2
1242.0
121.0
1136.0
Peso de Tara
43.4
Peso de Tara
434.0
3.2
106.0
Peso Seco
77.6
702.0
4.12%
12.63%
40.46
40
31.19
0.1718
17.53
20
12.63
21.65
30
14.69
MARRON
Contenido de humedad de la f raccin de Suelo seco que pasa % de suelo seco que pasa la malla No. 200
la malla # 4 :
:
80
70
0.057
0.172
0.344
0.0573
10
0 . 1
1.00
No.200
No.140
No.100
N o.60
N o.40
N o.30
1 . 0
N o.20
N o.16
N o.8
N o.10
3/8"
3/4"
1"
OBSERVACIONES :
0 . 0
1
N o.4
TAMIZ
1/2"
2"
3"
1 0 0 . 0
1 1/2"
8"
4"
1 0 0 0 .0
6"
Cont. de humedad %
0
0 . 0
Las gra vas mayore s a la N 4, de acuerdo a l mue streo en campo, e s de a proxima dame nte
EJECUTO
REVISO
APROBO
Vo. Bo.
LAB ORATORISTA
49.23%
RESULTADO
CUMPLE
FECHA:
12/02/2011
FECHA :
13/02/2011
FECHA :
14/02/2011
FECHA:
15-feb
SI
CUMPLE
SI
FECHA:
15-feb
MA PA DE PELIGROS, PLA N DE USOS DEL SUELO ANTE DESASTRES Y MEDIDAS DE MITIGACIN DE EL TA MBO, HUANCAYO Y CHILCA
ANALISIS GRANULOMETRICO
Ttulo:
Fecha de revisin:
15-feb-11
CAL./muestra
Proyecto:
ESTUDIO DE MAPA DE PELIGROS Y PLAN DE USO DE SUELOS ANTE DESASTRES Y MEDIDAS DE MITIGACION DE LA CIUDADES DE
HUANCAYO, EL TAMBO Y CHILCA
Contratante
M U N IC IP A LID A D P R OV IN C IA L D E H U A N C A Y O
Sondaje
S4
Profundidad:
2.00
T am ao
Tamiz
Mt.
Pes o R eten.
Ac umulado
07/02/2011
IN SITU
1.00
Ubicacin
HUANCAYO
%
R etenido
%
Pas a
8"
0.0
0.00%
100.00%
6"
0.0
0.00%
100.00%
4"
0.0
0.00%
100.00%
3"
0.0
0.00%
100.00%
2"
0.0
0.00%
100.00%
1 1/2"
0.0
0.00%
100.00%
1"
0.0
0.00%
100.00%
3/4"
60.0
9.93%
90.07%
BANDEJA
424.0
3/8"
128.0
21.19%
68.87%
1056.0
Especif ic.
No. 4
88.0
14.57%
54.30%
1028.0
No. 10
76.0
12.58%
41.72%
974.0
No. 20
66.0
10.93%
30.79%
604.0
No. 40
60.0
9.93%
20.86%
No. 60
26.0
4.30%
16.56%
No. 100
18.0
2.98%
13.58%
0.1
0.1
0.2
0.4
0.3
0.9
1.2
0.6
2.0
4.8
2.4
9.5
12.7
19.0
100.00
90
17
LP =
16
Cc= 1.50
Cu= 6.00
CLASIF.(SUCS/
ASHTOO):
Tamao en mm
GM
IP =
D 10 =
D 30 =
D 60 =
A-1-b ( 0 )
COLOR:
MARRON
Contenido de humedad de la f raccin de Suelo seco que pasa % de suelo seco que pasa la malla No. 200
la malla # 4 :
:
80
12.25%
68.87
4.64%
70
No. Tara
No. Tara
0.3551
60
54.30
105.6
1056.0
102.8
974.0
Peso de Tara
42.4
Peso de Tara
424.0
2.8
82.0
Peso Seco
60.4
550.0
4.64%
12.25%
50
41.72
40
30.79
0.1776
20.86
30
13.58
16.56
20
0.0592
10
12.25
0.059
0.178
0.355
PROCEDENCIA:
90.07
100
100.00
25.4
76.2
101.6
0.00%
50.8
12.25%
12.25%
37.5
1.32%
74.0
203.2
8.0
Platillo
152.4
No. 200
LL =
0 . 1
1.0 0
N o.200
N o.140
N o.100
N o.60
N o.40
N o.30
1 . 0
N o.20
N o.16
N o.8
N o.10
3/8"
3/4"
1/2"
1"
OBSERVACIONES :
0 . 0
1
No.4
TAMIZ
1 1/2"
2"
1 0 0 . 0
3"
8"
4"
1 0 0 0 .0
6"
Cont. de humedad %
0
0 . 0
Las gra vas mayore s a la N 4, de acuerdo a l mue streo en campo, e s de a proxima dame nte
EJECUTO
REVISO
APROBO
Vo. Bo.
LAB ORATORISTA
45.70%
RESULTADO
CUMPLE
FECHA:
12/02/2011
FECHA :
13/02/2011
FECHA :
14/02/2011
FECHA:
15-feb
SI
CUMPLE
SI
FECHA:
15-feb
MA PA DE PELIGROS, PLA N DE USOS DEL SUELO ANTE DESASTRES Y MEDIDAS DE MITIGACIN DE EL TA MBO, HUANCAYO Y CHILCA
ANALISIS GRANULOMETRICO
Ttulo:
Fecha de revisin:
15-feb-11
CAL./muestra
Proyecto:
ESTUDIO DE MAPA DE PELIGROS Y PLAN DE USO DE SUELOS ANTE DESASTRES Y MEDIDAS DE MITIGACION DE LA CIUDADES DE
HUANCAYO, EL TAMBO Y CHILCA
Contratante
M U N IC IP A LID A D P R OV IN C IA L D E H U A N C A Y O
Sondaje
S4
Profundidad:
T am ao
Tamiz
3.00
Mt.
Pes o R eten.
Ac umulado
%
R etenido
%
Pas a
07/02/2011
IN SITU
2.00
Especif ic.
HUANCAYO
8"
0.0
0.00%
100.00%
6"
0.0
0.00%
100.00%
4"
0.0
0.00%
100.00%
3"
0.0
0.00%
100.00%
2"
0.0
0.00%
100.00%
1 1/2"
56.0
8.54%
91.46%
1"
0.0
0.00%
91.46%
3/4"
140.0
21.34%
70.12%
BANDEJA
428.0
3/8"
114.0
17.38%
52.74%
1136.0
No. 4
60.0
9.15%
43.60%
1084.0
No. 10
56.0
8.54%
35.06%
988.0
No. 20
34.0
5.18%
29.88%
656.0
No. 40
40.0
6.10%
23.78%
No. 60
26.0
3.96%
19.82%
No. 100
18.0
2.74%
17.07%
No. 200
14.0
2.13%
14.94%
Platillo
98.0
14.94%
0.00%
LL =
0.1
0.1
0.2
0.4
0.3
0.9
1.2
0.6
2.0
4.8
2.4
9.5
12.7
19.0
25.4
Tamao en mm
91.46
91.46
101.6
76.2
PROCEDENCIA:
50.8
90
37.5
CLASIF.(SUCS/
ASHTOO):
203.2
100
152.4
LP =
GM
IP =
D 10 =
D 30 =
D 60 =
Cc= 1.50
Cu= 6.00
A-1-b ( 0 )
COLOR:
0.048
0.143
0.287
MARRON
Contenido de humedad de la f raccin de Suelo seco que pasa % de suelo seco que pasa la malla No. 200
la malla # 4 :
:
80
7.93%
70.12
70
No. Tara
14.94%
1
No. Tara
0.2867
60
52.74
113.6
1136.0
108.4
988.0
Peso de Tara
42.8
Peso de Tara
428.0
5.2
148.0
Peso Seco
65.6
560.0
7.93%
14.94%
50
43.60
40
29.88
35.06
Ubicacin
0.1433
14.94
20
17.07
19.82
23.7 8
30
0.0478
10
0 . 1
1.00
No.200
No.140
No.100
N o.60
N o.40
N o.30
1 . 0
N o.20
N o.16
N o.8
N o.10
3/8"
3/4"
1"
OBSERVACIONES :
0 . 0
1
N o.4
TAMIZ
1/2"
2"
3"
1 0 0 . 0
1 1/2"
8"
4"
1 0 0 0 .0
6"
Cont. de humedad %
0
0 . 0
Las gra vas mayore s a la N 4, de acuerdo a l mue streo en campo, e s de a proxima dame nte
EJECUTO
REVISO
APROBO
Vo. Bo.
LAB ORATORISTA
56.40%
RESULTADO
CUMPLE
FECHA:
12/02/2011
FECHA :
13/02/2011
FECHA :
14/02/2011
FECHA:
15-feb
SI
CUMPLE
SI
FECHA:
15-feb
MA PA DE PELIGROS, PLA N DE USOS DEL SUELO ANTE DESASTRES Y MEDIDAS DE MITIGACIN DE EL TA MBO, HUANCAYO Y CHILCA
ANALISIS GRANULOMETRICO
Ttulo:
Fecha de revisin:
15-feb-11
CAL./muestra
Proyecto:
ESTUDIO DE MAPA DE PELIGROS Y PLAN DE USO DE SUELOS ANTE DESASTRES Y MEDIDAS DE MITIGACION DE LA CIUDADES DE
HUANCAYO, EL TAMBO Y CHILCA
Contratante
M U N IC IP A LID A D P R OV IN C IA L D E H U A N C A Y O
Sondaje
S5
Profundidad:
T am ao
Tamiz
2.00
Mt.
Pes o R eten.
Ac umulado
%
R etenido
%
Pas a
07/02/2011
IN SITU
1.00
Especif ic.
Ubicacin
HUANCAYO
8"
0.0
0.00%
100.00%
6"
0.0
0.00%
100.00%
4"
0.0
0.00%
100.00%
3"
0.0
0.00%
100.00%
2"
0.0
0.00%
100.00%
104.0
15.52%
84.48%
0.0
0.00%
84.48%
3/4"
218.0
32.54%
51.94%
BANDEJA
422.0
3/8"
76.0
11.34%
40.60%
1116.0
1 1/2"
1"
No. 4
36.0
5.37%
35.22%
1092.0
No. 10
14.0
2.09%
33.13%
1076.0
No. 20
12.0
1.79%
31.34%
670.0
No. 40
120.0
17.91%
13.43%
No. 60
54.0
8.06%
5.37%
No. 100
14.0
2.09%
3.28%
No. 200
4.0
0.60%
2.69%
Platillo
18.0
2.69%
0.00%
LL =
0.1
0.1
0.2
0.4
0.3
0.9
1.2
0.6
2.0
4.8
2.4
9.5
12.7
19.0
25.4
Tamao en mm
84.48
84.48
101.6
76.2
PROCEDENCIA:
50.8
90
37.5
CLASIF.(SUCS/
ASHTOO):
203.2
100
152.4
LP =
GP
IP =
D 10 =
D 30 =
D 60 =
Cc= 1.50
Cu= 6.00
A-1-a(0)
COLOR:
0.395
1.185
2.369
MARRON
Contenido de humedad de la f raccin de Suelo seco que pasa % de suelo seco que pasa la malla No. 200
la malla # 4 :
:
80
3.58%
2.69%
No. Tara
No. Tara
2.3693
60
51.94
50
40.60
33.13
31.3 4
40
35.22
70
1.1847
30
111.6
1116.0
109.2
1076.0
Peso de Tara
42.2
Peso de Tara
422.0
2.4
40.0
Peso Seco
67.0
654.0
3.58%
2.69%
13.43
20
0.3949
0 . 1
Cont. de humedad %
1.00
2.69
5.37
3.28
No.140
No.100
N o.60
N o.40
N o.30
1 . 0
N o.20
N o.16
N o.8
N o.10
3/8"
3/4"
1"
OBSERVACIONES :
0 . 0
1
N o.4
TAMIZ
1/2"
2"
3"
1 0 0 . 0
1 1/2"
8"
4"
1 0 0 0 .0
6"
No.200
10
0 . 0
Las gra vas mayore s a la N 4, de acuerdo a l mue streo en campo, e s de a proxima dame nte
EJECUTO
REVISO
APROBO
Vo. Bo.
LAB ORATORISTA
64.78%
RESULTADO
CUMPLE
FECHA:
12/02/2011
FECHA :
13/02/2011
FECHA :
14/02/2011
FECHA:
15-feb
SI
CUMPLE
SI
FECHA:
15-feb
MA PA DE PELIGROS, PLA N DE USOS DEL SUELO ANTE DESASTRES Y MEDIDAS DE MITIGACIN DE EL TA MBO, HUANCAYO Y CHILCA
ANALISIS GRANULOMETRICO
Ttulo:
Fecha de revisin:
15-feb-11
CAL./mues tra
Proyecto:
ESTUDIO DE MAPA DE PELIGROS Y PLAN DE USO DE SUELOS ANTE DESASTRES Y MEDIDAS DE MITIGACION DE LA CIUDADES DE
HUANCAYO, EL TAMBO Y CHILCA
Contratante
M U N IC IP A L ID A D P R O VIN C IA L D E H UA N C A Y O
Sondaje
S5
Profundidad:
3.00
T amao
Tamiz
Mt.
Peso Reten.
Ac um ulado
Fecha muestreo:
07/02/2011
IN SITU
2.00
Ubicacin
HUANCAYO
%
Retenido
%
Pas a
8"
0.0
0.00%
100.00%
6"
0.0
0.00%
100.00%
4"
0.0
0.00%
100.00%
3"
0.0
0.00%
100.00%
2"
0.0
0.00%
100.00%
1 1/2"
0.0
0.00%
100.00%
1"
0.0
0.00%
100.00%
3/4"
398.0
53.64%
46.36%
BANDEJA
3/8"
92.0
12.40%
33.96%
1200.0
Especif ic .
434.0
30.0
4.04%
18.33%
No. 40
68.0
9.16%
9.16%
No. 60
42.0
5.66%
3.50%
No. 100
10.0
1.35%
2.16%
6.0
0.81%
1.35%
10.0
1.35%
0.00%
100
742.0
LL =
LP =
0.1
0.1
Cc= 1.50
Cu= 6.00
0.2
0.3
1.2
0.6
2.4
9.5
76.2
101.6
50.8
203.2
152.4
Platillo
37.5
No. 200
0.4
1166.0
No. 20
0.9
1176.0
2.0
22.37%
4.8
27.76%
5.39%
12.7
6.20%
40.0
19.0
100.00
46.0
100.00
25.4
No. 4
No. 10
CLASIF.(SUCS/
ASHTOO):
Tamao en mm
GP
IP =
D 10 =
D 30 =
D 60 =
A-1-a(0)
COLOR:
1.915
5.746
11.492
MARRON
PROCEDENCIA:
90
Contenido de humedad de la f raccin de Suelo seco que pasa % de suelo seco que pasa la malla No. 200
la malla # 4 :
:
80
3.23%
1.35%
No. Tara
60
No. Tara
11.4924
120
1200.0
50
46.36
117.6
1166.0
Peso de Tara
43.4
Peso de Tara
434.0
2.4
34.0
Peso Seco
74.2
732.0
Cont. de humedad %
3.23%
1.35%
40
33.96
70
22.37
27.76
5.7462
30
18.33
20
OBSERVACIONES :
1.00
1.35
2.16
0 . 1
No.200
No.140
No.100
N o.6 0
N o.4 0
N o.3 0
1 . 0
N o.2 0
N o.1 6
No.8
N o.1 0
3/8 "
3/4 "
1"
1/2"
1 0 . 0
N o.4
TAMIZ
1 1/2"
2"
1 0 0 .0
3"
8"
1 0 0 . 0
4"
6"
3.50
9.16
1.9154
10
0 . 0
EJECUTO
REVISO
APROBO
Vo. Bo.
LA BORA TORISTA
ROAD TECH SA C
72.24%
RESULTADO
CUMPLE
FECHA:
12/02/2011
FECHA:
13/02/2011
FECHA:
14/02/2011
FECHA :
15-feb
SI
CUMPLE
SI
FECHA :
15-feb
MA PA DE PELIGROS, PLA N DE USOS DEL SUELO ANTE DESASTRES Y MEDIDAS DE MITIGACIN DE EL TA MBO, HUANCAYO Y CHILCA
ANALISIS GRANULOMETRICO
Ttulo:
Fecha de revisin:
15-feb-11
CAL./mues tra
Proyecto:
ESTUDIO DE MAPA DE PELIGROS Y PLAN DE USO DE SUELOS ANTE DESASTRES Y MEDIDAS DE MITIGACION DE LA CIUDADES DE
HUANCAYO, EL TAMBO Y CHILCA
Contratante
M UN IC IP A L ID A D P R OV IN C IA L D E H U A N C A Y O
Sondaje
S6
Profundidad:
T amao
Tamiz
2.00
Mt.
Peso Reten.
A cumulado
%
Retenido
%
Pasa
Fecha muestreo:
07/02/2011
Muestreado por:
IN SITU
Muestra No.
1.00
Especific.
Ubicacin
SUNARP - HYO
8"
0.0
0.00%
100.00%
6"
0.0
0.00%
100.00%
4"
0.0
0.00%
100.00%
3"
0.0
0.00%
100.00%
2"
0.0
0.00%
100.00%
640.0
83.33%
16.67%
1"
0.0
0.00%
16.67%
3/4"
42.0
5.47%
11.20%
BANDEJA
3/8"
18.0
2.34%
8.85%
1214.0
1 1/2"
426.0
No. 4
14.0
1.82%
7.03%
1194.0
No. 10
12.0
1.56%
5.47%
1182.0
No. 20
10.0
1.30%
4.17%
No. 40
10.0
1.30%
2.86%
No. 60
4.0
0.52%
2.34%
No. 100
4.0
0.52%
1.82%
No. 200
2.0
0.26%
1.56%
Platillo
12.0
1.56%
0.00%
LL =
0.1
0.1
0.2
0.4
0.3
0.9
1.2
0.6
2.0
4.8
2.4
9.5
12.7
19.0
25.4
76.2
37.5
PROCEDENCIA:
101.6
90
50.8
CLASIF.(SUCS/
ASHTOO):
203.2
LP =
Cc= 1.50
Cu= 6.00
100
152.4
768.0
Tamao en mm
GP
IP =
D 10 =
D 30 =
D 60 =
A-1-b(0)
COLOR:
1.184
3.552
7.104
MARRON
Contenido de humedad de la fracci n de Suelo seco que pasa % de suelo seco que pasa la malla No. 200
la malla # 4 :
:
80
2.60%
1.56%
70
No. Tara
60
No. Tara
7.1040
121.4
1214.0
119.4
1182.0
Peso de Tara
42.6
Peso de Tara
426.0
2.0
32.0
Peso Seco
76.8
756.0
2.60%
1.56%
50
40
3.5 520
30
16.67
1.56
1.00
No.140
No.100
2.34
N o.6 0
N o.4 0
0 . 1
No.200 1.82
Cont. de humedad %
2.86
4.17
N o.3 0
1 .0
N o.2 0
N o.1 6
No.8
N o.1 0
5.47
7.03
8.85
1 0
. 0
3/8 "
3/4 "
1"
OBSERVACIONES :
1.1840
N o.4
TAMIZ
1 1/2"
2"
1 0 . 0
3"
8"
1 0 0 . 0
4"
6"
10
1/2"
11.20
16.67
20
0 . 0
Las gra vas mayore s a la N 4, de acuerdo a l mue streo en campo, es de aprox ima dame nte
EJECUTO
REVISO
APROBO
Vo. Bo.
LA BORA TORISTA
92.97%
RESULTADO
CUMPLE
FECHA:
12/02/2011
FECHA :
13/02/2011
FECHA:
14/02/2011
FECHA:
15-feb
SI
CUMPLE
SI
FECHA :
15-feb
MA PA DE PELIGROS, PLA N DE USOS DEL SUELO ANTE DESASTRES Y MEDIDAS DE MITIGACIN DE EL TA MBO, HUANCAYO Y CHILCA
ANALISIS GRANULOMETRICO
Ttulo:
Fecha de revisin:
15-feb-11
CAL./mues tra
Proyecto:
ESTUDIO DE MAPA DE PELIGROS Y PLAN DE USO DE SUELOS ANTE DESASTRES Y MEDIDAS DE MITIGACION DE LA CIUDADES DE
HUANCAYO, EL TAMBO Y CHILCA
Contratante
M UN IC IP A L ID A D P R OV IN C IA L D E H U A N C A Y O
Sondaje
S6
Profundidad:
T amao
Tamiz
3.00
Mt.
Peso Reten.
A cumulado
%
Retenido
%
Pasa
Fecha muestreo:
07/02/2011
Muestreado por:
IN SITU
Muestra No.
2.00
Especific.
Ubicacin
SUNARP - HYO
8"
0.0
0.00%
100.00%
6"
0.0
0.00%
100.00%
4"
0.0
0.00%
100.00%
3"
0.0
0.00%
100.00%
2"
0.0
0.00%
100.00%
1 1/2"
0.0
0.00%
100.00%
1"
0.0
0.00%
100.00%
3/4"
138.0
18.96%
81.04%
BANDEJA
3/8"
184.0
25.27%
55.77%
1190.0
432.0
No. 4
100.0
13.74%
42.03%
1160.0
No. 10
98.0
13.46%
28.57%
1122.0
No. 20
68.0
9.34%
19.23%
No. 40
60.0
8.24%
10.99%
100
LL =
LP =
0.1
0.1
Cc= 1.50
Cu= 6.00
0.2
0.4
0.3
0.9
1.2
0.6
2.0
2.4
9.5
4.8
0.00%
12.7
5.22%
5.22%
37.5
1.37%
38.0
19.0
100.00
10.0
Platillo
100.00
25.4
No. 200
101.6
6.59%
76.2
8.24%
1.65%
50.8
2.75%
12.0
203.2
20.0
152.4
No. 60
No. 100
728.0
CLASIF.(SUCS/
ASHTOO):
Tamao en mm
GP-GM
IP =
D 10 =
D 30 =
D 60 =
COLOR:
A-1-b(0)
0.158
0.473
0.947
MARRON
PROCEDENCIA:
90
Contenido de humedad de la fracci n de Suelo seco que pasa % de suelo seco que pasa la malla No. 200
la malla # 4 :
:
81.04
80
4.12%
5.22%
No. Tara
No. Tara
0.9470
60
55.77
1190.0
116.0
119
1122.0
Peso de Tara
43.2
Peso de Tara
432.0
3.0
68.0
Peso Seco
72.8
690.0
4.12%
5.22%
50
42.03
40
0.4735
Cont. de humedad %
1.00
5.22
6.59
0 . 1
N o.200
N o.40
N o.30
1 .0
N o.20
N o.16
N o.8
N o.10
3/8"
1/2"
3/4"
1"
OBSERVACIONES :
1 0
. 0
N o.4
TAMIZ
1 1/2"
2"
1 0 . 0
3"
4"
8"
1 0 0 . 0
6"
N o.140
0.1578
10
N o.100
10.99
20
8.24
19.23
28.57
30
N o.60
70
0 . 0
Las gra vas mayore s a la N 4, de acuerdo a l mue streo en campo, es de aprox ima dame nte
EJECUTO
REVISO
APROBO
Vo. Bo.
LA BORA TORISTA
57.97%
RESULTADO
CUMPLE
FECHA:
12/02/2011
FECHA :
13/02/2011
FECHA:
14/02/2011
FECHA:
15-feb
SI
CUMPLE
SI
FECHA :
15-feb
MA PA DE PELIGROS, PLA N DE USOS DEL SUELO ANTE DESASTRES Y MEDIDAS DE MITIGACIN DE EL TA MBO, HUANCAYO Y CHILCA
ANALISIS GRANULOMETRICO
Ttulo:
Fecha de revisin:
15-feb-11
CAL./mues tra
Proyecto:
ESTUDIO DE MAPA DE PELIGROS Y PLAN DE USO DE SUELOS ANTE DESASTRES Y MEDIDAS DE MITIGACION DE LA CIUDADES DE
HUANCAYO, EL TAMBO Y CHILCA
Contratante
M UN IC IP A L ID A D P R OVIN C IA L D E H U A N C A YO
Sondaje
S7
Profundidad:
2.00
Tam ao
Tamiz
P es o Reten.
Ac um ulado
Mt.
07/02/2011
Muestreado por:
IN SITU
Muestra No.
1.00
Ubicacin
HUANCAYO
%
R etenido
%
Pasa
8"
0.0
0.00%
100.00%
6"
0.0
0.00%
100.00%
4"
0.0
0.00%
100.00%
3"
0.0
0.00%
100.00%
2"
0.0
0.00%
100.00%
60.0
9.49%
90.51%
0.0
0.00%
90.51%
3/4"
152.0
24.05%
66.46%
BANDEJA
3/8"
132.0
20.89%
45.57%
1110.0
1058.0
1 1/2"
1"
Es pec ific.
426.0
No. 4
50.0
7.91%
37.66%
No. 10
36.0
5.70%
31.96%
982.0
No. 20
3.80%
6.33%
28.16%
21.84%
632.0
No. 40
24.0
40.0
LL =
0 .1
0.1
CLASIF.(SUCS/
ASHTOO):
Tamao en mm
LP =
GM
IP =
D 10 =
D 30 =
D 60 =
A-1-a ( 0 )
0.054
0.163
0.325
COLOR:
MARRON
PROCEDENCIA:
9 0 .51
9 0 .51
100
90
Cc= 1.50
Cu= 6.00
0 .2
0 .4
0.3
0.9
1.2
0 .6
4.8
2.4
9 .5
2 .0
0.00%
12 .7
13.29%
13.29%
19 .0
1.90%
84.0
25 .4
12.0
Platillo
1 01 .6
No. 200
7 6 .2
15.19%
37 .5
17.72%
2.53%
5 0 .8
4.11%
16.0
2 03 .2
26.0
15 2 .4
No. 60
No. 100
Contenido de humedad de la frac cin de Suelo s ec o que pasa % de suelo seco que pasa la malla No. 200
la malla # 4 :
:
80
8.23%
13.29%
6 6.4 6
No. Tara
No. Tara
0 .3 25 1
60
111
1110.0
50
4 5 .57
40
105.8
982.0
3 1 .9 6
3 7.6 6
Pes o de Tara
42.6
Peso de Tara
426.0
5.2
128.0
Pes o Sec o
63.2
556.0
8.23%
13.29%
0 .1 6 2 6
1 7 .7 2
20
1 3 .29
2 1.8 4
2 8 .16
30
1 5 .19
70
0.0 54 2
10
0 . 1
1 .0 0
No.2 00
No.1 40
No.1 00
N o.60
N o.40
N o.30
1 . 0
N o.20
N o.16
N o.8
N o.10
3 /8 "
3 /4 "
1"
OBSERVACIONES :
0 . 0
1
N o.4
TAMIZ
1 /2"
2"
3"
1 0 0 . 0
1 1 /2 "
8"
4"
1 0 0 0
. 0
6"
Cont. de humedad %
0
0 . 0
EJECUTO
REVISO
APROBO
Vo. Bo.
LAB OR ATORISTA
62.34%
RES ULTADO
CUMPLE
FECHA:
12/02/2011
FECHA:
13/02/2011
FECHA:
14/02/2011
FECHA:
15-f eb
SI
CUMPLE
SI
FECHA:
15-feb
MA PA DE PELIGROS, PLA N DE USOS DEL SUELO ANTE DESASTRES Y MEDIDAS DE MITIGACIN DE EL TA MBO, HUANCAYO Y CHILCA
ANALISIS GRANULOMETRICO
Ttulo:
Fecha de revisin:
15-feb-11
CAL./mues tra
Proyecto:
ESTUDIO DE MAPA DE PELIGROS Y PLAN DE USO DE SUELOS ANTE DESASTRES Y MEDIDAS DE MITIGACION DE LA CIUDADES DE
HUANCAYO, EL TAMBO Y CHILCA
Contratante
M UN IC IP A L ID A D P R OV IN C IA L D E H U A N C A Y O
Sondaje
S7
Profundidad:
3.00
T amao
Tamiz
Mt.
Peso Reten.
A cumulado
Fecha muestreo:
07/02/2011
Muestreado por:
IN SITU
Muestra No.
2.00
Ubicacin
HUANCAYO
%
Retenido
%
Pasa
8"
0.0
0.00%
100.00%
6"
0.0
0.00%
100.00%
4"
0.0
0.00%
100.00%
3"
0.0
0.00%
100.00%
2"
0.0
0.00%
100.00%
226.0
31.65%
68.35%
0.0
0.00%
68.35%
3/4"
118.0
16.53%
51.82%
BANDEJA
3/8"
98.0
13.73%
38.10%
1180.0
1 1/2"
1"
Especific.
430.0
No. 4
68.0
9.52%
28.57%
1144.0
No. 10
56.0
7.84%
20.73%
1120.0
No. 20
30.0
4.20%
16.53%
No. 40
40.0
5.60%
10.92%
No. 60
22.0
3.08%
7.84%
No. 100
14.0
1.96%
5.88%
No. 200
8.0
1.12%
4.76%
Platillo
34.0
4.76%
0.00%
LL =
0.1
0.1
0.2
0.4
0.3
0.9
1.2
0.6
2.0
4.8
2.4
9.5
12.7
19.0
25.4
76.2
37.5
PROCEDENCIA:
101.6
90
50.8
CLASIF.(SUCS/
ASHTOO):
203.2
LP =
Cc= 1.50
Cu= 6.00
100
152.4
714.0
Tamao en mm
GP
IP =
D 10 =
D 30 =
D 60 =
A-1-b(0)
COLOR:
MARRON
Contenido de humedad de la fracci n de Suelo seco que pasa % de suelo seco que pasa la malla No. 200
la malla # 4 :
:
80
68.35
4.76%
68.35
5.04%
70
No. Tara
60
No. Tara
1.0622
51.82
50
40
118
1180.0
114.4
1120.0
Peso de Tara
43.0
Peso de Tara
430.0
3.6
60.0
Peso Seco
71.4
690.0
5.04%
4.76%
38.10
0.177
0.531
1.062
0.5311
20.73
28.57
30
10.92
16.53
20
Cont. de humedad %
1.00
4.76
5.88
0 . 1
No.200
No.140
No.100
7.84
N o.6 0
N o.3 0
1 .0
N o.2 0
N o.1 6
No.8
N o.1 0
3/8 "
3/4 "
1/2"
1"
OBSERVACIONES :
1 0
. 0
N o.4
TAMIZ
1 1/2"
2"
1 0 . 0
3"
8"
4"
1 0 0 . 0
6"
N o.4 0
0.1770
10
0 . 0
Las gra vas mayore s a la N 4, de acuerdo a l mue streo en campo, es de aprox ima dame nte
EJECUTO
REVISO
APROBO
Vo. Bo.
LA BORA TORISTA
71.43%
RESULTADO
CUMPLE
FECHA:
12/02/2011
FECHA :
13/02/2011
FECHA:
14/02/2011
FECHA:
15-feb
SI
CUMPLE
SI
FECHA :
15-feb
MA PA DE PELIGROS, PLA N DE USOS DEL SUELO ANTE DESASTRES Y MEDIDAS DE MITIGACIN DE EL TA MBO, HUANCAYO Y CHILCA
ANALISIS GRANULOMETRICO
Ttulo:
Fecha de revisin:
15-feb-11
CAL./mues tra
Proyecto:
ESTUDIO DE MAPA DE PELIGROS Y PLAN DE USO DE SUELOS ANTE DESASTRES Y MEDIDAS DE MITIGACION DE LA CIUDADES DE
HUANCAYO, EL TAMBO Y CHILCA
Contratante
M UN IC IP A L ID A D P R OV IN C IA L D E H U A N C A Y O
Sondaje
S8
Profundidad:
3.00
T amao
Tamiz
Mt.
Peso Reten.
A cumulado
Fecha muestreo:
07/02/2011
Muestreado por:
IN SITU
Muestra No.
2.00
Ubicacin
HUANCAYO
%
Retenido
%
Pasa
8"
0.0
0.00%
100.00%
6"
0.0
0.00%
100.00%
4"
0.0
0.00%
100.00%
3"
0.0
0.00%
100.00%
2"
0.0
0.00%
100.00%
145.0
25.35%
74.65%
0.0
0.00%
74.65%
3/4"
120.0
20.98%
53.67%
BANDEJA
3/8"
24.0
4.20%
49.48%
1132.0
1030.0
1 1/2"
1"
Especific.
458.0
No. 4
38.0
6.64%
42.83%
No. 10
56.0
9.79%
33.04%
756.0
No. 20
34.0
5.94%
27.10%
572.0
No. 40
36.0
6.29%
20.80%
No. 60
16.0
2.80%
18.01%
No. 100
16.0
2.80%
15.21%
No. 200
18.0
3.15%
12.06%
Platillo
69.0
12.06%
0.00%
LL =
0.1
0.1
0.2
0.4
0.3
0.9
1.2
0.6
2.0
4.8
2.4
9.5
12.7
19.0
25.4
76.2
37.5
PROCEDENCIA:
101.6
90
50.8
CLASIF.(SUCS/
ASHTOO):
203.2
100
152.4
LP =
Cc= 1.50
Cu= 6.00
Tamao en mm
GM
IP =
D 10 =
D 30 =
D 60 =
A-1-a ( 0 )
COLOR:
0.060
0.181
0.361
MARRON
Contenido de humedad de la fracci n de Suelo seco que pasa % de suelo seco que pasa la malla No. 200
la malla # 4 :
:
74.65
74.65
80
17.83%
12.06%
No. Tara
60
No. Tara
0.3612
113.2
1132.0
103.0
756.0
Peso de Tara
45.8
Peso de Tara
458.0
10.2
376.0
Peso Seco
57.2
298.0
17.83%
12.06%
49.48
53.67
50
42.83
40
33.04
70
0.1806
0.0602
10
12.06
15.21
20
18.01
20.80
27.10
30
0 . 1
1.00
No.200
No.140
No.100
N o.6 0
N o.4 0
N o.3 0
1 .0
N o.2 0
N o.1 6
No.8
N o.1 0
3/8 "
3/4 "
1/2"
1"
OBSERVACIONES :
1 0
. 0
N o.4
TAMIZ
1 1/2"
2"
1 0 . 0
3"
8"
4"
1 0 0 . 0
6"
Cont. de humedad %
0
0 . 0
Las gra vas mayore s a la N 4, de acuerdo a l mue streo en campo, es de aprox ima dame nte
EJECUTO
REVISO
APROBO
Vo. Bo.
LA BORA TORISTA
57.17%
RESULTADO
CUMPLE
FECHA:
12/02/2011
FECHA :
13/02/2011
FECHA:
14/02/2011
FECHA:
15-feb
SI
CUMPLE
SI
FECHA :
15-feb
MA PA DE PELIGROS, PLA N DE USOS DEL SUELO ANTE DESASTRES Y MEDIDAS DE MITIGACIN DE EL TA MBO, HUANCAYO Y CHILCA
ANALISIS GRANULOMETRICO
Ttulo:
Fecha de revisin:
15-feb-11
CAL./mues tra
Proyecto:
ESTUDIO DE MAPA DE PELIGROS Y PLAN DE USO DE SUELOS ANTE DESASTRES Y MEDIDAS DE MITIGACION DE LA CIUDADES DE
HUANCAYO, EL TAMBO Y CHILCA
Contratante
M U N IC IP A L ID A D P R O VIN C IA L D E H UA N C A Y O
Sondaje
S9
Profundidad:
1.00
T amao
Tamiz
Mt.
Peso Reten.
Ac um ulado
Fecha muestreo:
07/02/2011
IN SITU
1.00
Ubicacin
HUANCAYO
%
Retenido
%
Pas a
8"
0.0
0.00%
100.00%
6"
0.0
0.00%
100.00%
4"
0.0
0.00%
100.00%
3"
0.0
0.00%
100.00%
2"
0.0
0.00%
100.00%
1 1/2"
0.0
0.00%
100.00%
1"
0.0
0.00%
100.00%
3/4"
81.0
14.11%
85.89%
BANDEJA
3/8"
76.0
13.24%
72.65%
1118.0
1004.0
Especif ic .
430.0
No. 4
76.0
13.24%
59.41%
No. 10
78.0
13.59%
45.82%
996.0
No. 20
58.0
10.10%
35.71%
574.0
No. 40
64.0
11.15%
24.56%
100
LL =
LP =
0.1
0.1
Cc= 1.50
Cu= 6.00
0.2
0.4
0.3
0.9
1.2
0.6
2.0
2.4
9.5
4.8
0.00%
12.7
12.72%
12.72%
37.5
1.74%
73.0
19.0
100.00
10.0
Platillo
100.00
25.4
No. 200
101.6
14.46%
76.2
18.29%
3.83%
50.8
6.27%
22.0
203.2
36.0
152.4
No. 60
No. 100
CLASIF.(SUCS/
ASHTOO):
Tamao en mm
SM
IP =
D 10 =
D 30 =
D 60 =
COLOR:
A-1-b ( 0 )
0.057
0.171
0.341
MARRON
PROCEDENCIA:
85.89
90
Contenido de humedad de la f raccin de Suelo seco que pasa % de suelo seco que pasa la malla No. 200
la malla # 4 :
:
80
72.65
19.86%
12.72%
No. Tara
59.41
60
No. Tara
0.3410
111.8
1118.0
100.4
996.0
Peso de Tara
43.0
Peso de Tara
430.0
11.4
122.0
Peso Seco
57.4
566.0
19.86%
12.72%
50
45.82
40
35.71
70
0.1705
24.5 6
30
0.0568
10
12.72
14.46
18.29
20
OBSERVACIONES :
0 . 1
1.00
N o.200
N o.140
N o.100
N o.60
N o.40
N o.30
1 . 0
N o.20
N o.16
N o.8
N o.10
3/8"
1/2"
3/4"
1"
1 0 . 0
N o.4
TAMIZ
1 1/2"
2"
1 0 0 .0
3"
4"
8"
1 0 0 . 0
6"
Cont. de humedad %
0
0 . 0
EJECUTO
REVISO
APROBO
Vo. Bo.
LA BORA TORISTA
ROAD TECH SA C
40.59%
RESULTADO
CUMPLE
FECHA:
12/02/2011
FECHA:
13/02/2011
FECHA:
14/02/2011
FECHA :
15-feb
SI
CUMPLE
SI
FECHA :
15-feb
MA PA DE PELIGROS, PLA N DE USOS DEL SUELO ANTE DESASTRES Y MEDIDAS DE MITIGACIN DE EL TA MBO, HUANCAYO Y CHILCA
ANALISIS GRANULOMETRICO
Ttulo:
Fecha de revisin:
15-feb-11
CAL./mues tra
Proyecto:
ESTUDIO DE MAPA DE PELIGROS Y PLAN DE USO DE SUELOS ANTE DESASTRES Y MEDIDAS DE MITIGACION DE LA CIUDADES DE
HUANCAYO, EL TAMBO Y CHILCA
Contratante
M UN IC IP A L ID A D P R OV IN C IA L D E H U A N C A Y O
Sondaje
S9
Profundidad:
2.00
T amao
Tamiz
Mt.
Peso Reten.
A cumulado
Fecha muestreo:
07/02/2011
Muestreado por:
IN SITU
Muestra No.
2.00
Ubicacin
HUANCAYO
%
Retenido
%
Pasa
8"
0.0
0.00%
100.00%
6"
0.0
0.00%
100.00%
4"
0.0
0.00%
100.00%
3"
0.0
0.00%
100.00%
2"
0.0
0.00%
100.00%
1 1/2"
0.0
0.00%
100.00%
1"
0.0
0.00%
100.00%
3/4"
0.0
0.00%
100.00%
BANDEJA
3/8"
0.0
0.00%
100.00%
1110.0
1082.0
Especific.
422.0
1.21%
97.58%
660.0
No. 40
6.0
0.91%
96.67%
No. 60
0.0
0.00%
96.67%
No. 100
0.0
0.00%
96.67%
4.0
0.61%
96.06%
634.0
96.06%
0.00%
LP =
0.1
0.1
CLASIF.(SUCS/
ASHTOO):
Tamao en mm
ML
IP =
D 10 =
D 30 =
D 60 =
A-4 ( 8 )
COLOR:
0.007
0.021
0.042
MARRON
96.06
0.2
Cc= 1.50
Cu= 6.00
96.6 7
0.3
LL =
96.6 7
96.6 7
1.2
97.58 0.6
98.79
9.5
100.00
100
100.00
76.2
37.5
101.6
203.2
152.4
Platillo
50.8
No. 200
0.4
8.0
0.9
458.0
No. 20
2.0
4.8
98.79%
2.4
100.00%
1.21%
100.00
12.7
0.00%
8.0
19.0
100.00
0.0
100.00
25.4
No. 4
No. 10
PROCEDENCIA:
90
Contenido de humedad de la fracci n de Suelo seco que pasa % de suelo seco que pasa la malla No. 200
la malla # 4 :
:
80
4.24%
96.06%
70
No. Tara
60
No. Tara
0.0420
111
1110.0
50
108.2
458.0
Peso de Tara
42.2
Peso de Tara
422.0
2.8
652.0
Peso Seco
66.0
36.0
4.24%
96.06%
40
0.0210
30
20
10
0 . 1
1.00
No.200
No.140
No.100
N o.6 0
N o.4 0
N o.3 0
1 .0
N o.2 0
N o.1 6
No.8
N o.1 0
3/8 "
3/4 "
1/2"
1"
OBSERVACIONES :
1 0
. 0
N o.4
TAMIZ
1 1/2"
2"
1 0 . 0
3"
8"
4"
1 0 0 . 0
6"
Cont. de humedad %
0
0 . 0
Las gra vas mayore s a la N 4, de acuerdo a l mue streo en campo, es de aprox ima dame nte
EJECUTO
REVISO
APROBO
Vo. Bo.
LA BORA TORISTA
0.00%
RESULTADO
CUMPLE
FECHA:
12/02/2011
FECHA :
13/02/2011
FECHA:
14/02/2011
FECHA:
15-feb
SI
CUMPLE
SI
FECHA :
15-feb
MA PA DE PELIGROS, PLA N DE USOS DEL SUELO ANTE DESASTRES Y MEDIDAS DE MITIGACIN DE EL TA MBO, HUANCAYO Y CHILCA
ANALISIS GRANULOMETRICO
Ttulo:
Fecha de revisin:
15-feb-11
CAL./mues tra
Proyecto:
ESTUDIO DE MAPA DE PELIGROS Y PLAN DE USO DE SUELOS ANTE DESASTRES Y MEDIDAS DE MITIGACION DE LA CIUDADES DE
HUANCAYO, EL TAMBO Y CHILCA
Contratante
M U N IC IP A L ID A D P R O VIN C IA L D E H UA N C A Y O
Sondaje
S9
Profundidad:
3.00
Mt.
Peso Reten.
Ac um ulado
%
Retenido
%
Pas a
T amao
Tamiz
Fecha muestreo:
07/02/2011
IN SITU
3.00
Especif ic .
Ubicacin
HUANCAYO
8"
0.0
0.00%
100.00%
6"
0.0
0.00%
100.00%
4"
0.0
0.00%
100.00%
3"
0.0
0.00%
100.00%
2"
0.0
0.00%
100.00%
1 1/2"
0.0
0.00%
100.00%
1"
0.0
0.00%
100.00%
3/4"
0.0
0.00%
100.00%
BANDEJA
3/8"
0.0
0.00%
100.00%
1116.0
1100.0
432.0
No. 4
0.0
0.00%
100.00%
No. 10
6.0
0.90%
99.10%
724.0
No. 20
0.0
0.00%
99.10%
668.0
No. 40
18.0
2.69%
96.41%
No. 60
118.0
17.66%
78.74%
No. 100
96.0
14.37%
64.37%
0.1
0.1
0.2
0.4
0.3
LP =
Cc= 1.50
Cu= 6.00
CLASIF.(SUCS/
ASHTOO):
Tamao en mm
ML
IP =
D 10 =
D 30 =
D 60 =
COLOR:
A-4 ( 4 )
0.012
0.036
0.071
MARRON
96.41
0.9
1.2
99.100.6
2.0
99.10
4.8
2.4
9.5
100.00
100.00
100.00
12.7
37.5
19.0
100.00
100
100.00
25.4
101.6
0.00%
76.2
57.19%
57.19%
50.8
7.19%
382.0
203.2
48.0
Platillo
152.4
No. 200
LL =
PROCEDENCIA:
90
Contenido de humedad de la f raccin de Suelo seco que pasa % de suelo seco que pasa la malla No. 200
la malla # 4 :
:
78.74
80
2.40%
57.19%
64.37
No. Tara
No. Tara
0.0711
60
57.19
70
111.6
1116.0
110.0
724.0
Peso de Tara
43.2
Peso de Tara
432.0
1.6
392.0
Peso Seco
66.8
292.0
Cont. de humedad %
2.40%
57.19%
50
40
0.0356
30
20
OBSERVACIONES :
0 . 1
N o.200
N o.140
N o.100
N o.60
N o.40
N o.30
1 . 0
N o.20
N o.16
N o.8
N o.10
3/8"
1/2"
3/4"
1"
1 0 . 0
N o.4
TAMIZ
1 1/2"
2"
1 0 0 .0
3"
4"
8"
1 0 0 . 0
6"
1.00
0.0119
10
0 . 0
EJECUTO
REVISO
APROBO
Vo. Bo.
LA BORA TORISTA
ROAD TECH SA C
0.00%
RESULTADO
CUMPLE
FECHA:
12/02/2011
FECHA:
13/02/2011
FECHA:
14/02/2011
FECHA :
15-feb
SI
CUMPLE
SI
FECHA :
15-feb
MA PA DE PELIGROS, PLA N DE USOS DEL SUELO ANTE DESASTRES Y MEDIDAS DE MITIGACIN DE EL TA MBO, HUANCAYO Y CHILCA
ANALISIS GRANULOMETRICO
Ttulo:
Fecha de revisin:
15-feb-11
CAL./mues tra
Proyecto:
ESTUDIO DE MAPA DE PELIGROS Y PLAN DE USO DE SUELOS ANTE DESASTRES Y MEDIDAS DE MITIGACION DE LA CIUDADES DE
HUANCAYO, EL TAMBO Y CHILCA
Contratante
M UN IC IP A L ID A D P R OV IN C IA L D E H U A N C A Y O
Sondaje
S10
Profundidad:
T amao
Tamiz
2.50
Mt.
Peso Reten.
A cumulado
%
Retenido
%
Pasa
07/02/2011
Muestreado por:
IN SITU
Muestra No.
1.00
Especific.
Ubicacin
PUENTE CENTENARIO
8"
0.0
0.00%
100.00%
6"
0.0
0.00%
100.00%
4"
0.0
0.00%
100.00%
3"
0.0
0.00%
100.00%
2"
0.0
0.00%
100.00%
1 1/2"
0.0
0.00%
100.00%
1"
0.0
0.00%
100.00%
3/4"
80.0
12.20%
87.80%
BANDEJA
3/8"
56.0
8.54%
79.27%
1170.0
1080.0
424.0
No. 4
58.0
8.84%
70.43%
No. 10
60.0
9.15%
61.28%
922.0
No. 20
40.0
6.10%
55.18%
656.0
No. 40
84.0
12.80%
42.38%
No. 60
56.0
8.54%
33.84%
No. 100
42.0
6.40%
27.44%
19
LP =
17
CLASIF.(SUCS/
ASHTOO):
Tamao en mm
0.1
0.1
Cc= 1.50
Cu= 6.00
0.2
0.4
0.3
0.9
1.2
0.6
2.0
4.8
2.4
9.5
LL =
SM
IP =
D 10 =
D 30 =
D 60 =
COLOR:
A-1-b ( 0 )
0.029
0.087
0.173
MARRON
PROCEDENCIA:
87.80
90
12.7
37.5
19.0
100.00
100.00
25.4
101.6
0.00%
76.2
24.09%
24.09%
50.8
3.35%
158.0
203.2
22.0
Platillo
152.4
No. 200
100
Contenido de humedad de la fracci n de Suelo seco que pasa % de suelo seco que pasa la malla No. 200
la malla # 4 :
:
79.27
13.72%
70.43
80
No. Tara
61.28
70
60
24.09%
1
No. Tara
0.1731
55.18
1170.0
108.0
117
922.0
Peso de Tara
42.4
Peso de Tara
424.0
9.0
248.0
Peso Seco
65.6
498.0
13.72%
24.09%
42.38
50
40
33.84
Fecha muestreo:
0.0 865
24.09
27.44
30
20
0.0288
10
0 . 1
1.00
N o.200
N o.140
N o.100
N o.60
N o.40
N o.30
1 .0
N o.20
N o.16
N o.8
N o.10
3/8"
1/2"
3/4"
1"
OBSERVACIONES :
1 0
. 0
N o.4
TAMIZ
1 1/2"
2"
1 0 . 0
3"
4"
8"
1 0 0 . 0
6"
Cont. de humedad %
0
0 . 0
Las gra vas mayore s a la N 4, de acuerdo a l mue streo en campo, es de aprox ima dame nte
EJECUTO
REVISO
APROBO
Vo. Bo.
LA BORA TORISTA
29.57%
RESULTADO
CUMPLE
FECHA:
12/02/2011
FECHA :
13/02/2011
FECHA:
14/02/2011
FECHA:
15-feb
SI
CUMPLE
SI
FECHA :
15-feb
MA PA DE PELIGROS, PLA N DE USOS DEL SUELO ANTE DESASTRES Y MEDIDAS DE MITIGACIN DE EL TA MBO, HUANCAYO Y CHILCA
ANALISIS GRANULOMETRICO
Ttulo:
Fecha de revisin:
15-feb-11
CAL./mues tra
Proyecto:
ESTUDIO DE MAPA DE PELIGROS Y PLAN DE USO DE SUELOS ANTE DESASTRES Y MEDIDAS DE MITIGACION DE LA CIUDADES DE
HUANCAYO, EL TAMBO Y CHILCA
Contratante
M UN IC IP A L ID A D P R OV IN C IA L D E H U A N C A Y O
Sondaje
S10
Profundidad:
2.50
T amao
Tamiz
Mt.
Peso Reten.
A cumulado
07/02/2011
Muestreado por:
IN SITU
Muestra No.
1.00
Ubicacin
PUENTE CENTENARIO
%
Retenido
%
Pasa
8"
0.0
0.00%
100.00%
6"
0.0
0.00%
100.00%
4"
0.0
0.00%
100.00%
3"
0.0
0.00%
100.00%
2"
0.0
0.00%
100.00%
1 1/2"
0.0
0.00%
100.00%
1"
0.0
0.00%
100.00%
3/4"
80.0
12.20%
87.80%
BANDEJA
3/8"
56.0
8.54%
79.27%
1170.0
1080.0
Especific.
424.0
No. 4
58.0
8.84%
70.43%
No. 10
60.0
9.15%
61.28%
922.0
No. 20
40.0
6.10%
55.18%
656.0
No. 40
84.0
12.80%
42.38%
No. 60
56.0
8.54%
33.84%
No. 100
42.0
6.40%
27.44%
19
LP =
17
CLASIF.(SUCS/
ASHTOO):
Tamao en mm
0.1
0.1
Cc= 1.50
Cu= 6.00
0.2
0.4
0.3
0.9
1.2
0.6
2.0
4.8
2.4
9.5
LL =
SM
IP =
D 10 =
D 30 =
D 60 =
A-1-b ( 0 )
COLOR:
0.029
0.087
0.173
MARRON
PROCEDENCIA:
87.80
90
12.7
19.0
100.00
100.00
25.4
76.2
37.5
0.00%
101.6
24.09%
24.09%
50.8
3.35%
158.0
203.2
22.0
Platillo
152.4
No. 200
100
Contenido de humedad de la fracci n de Suelo seco que pasa % de suelo seco que pasa la malla No. 200
la malla # 4 :
:
79.27
13.72%
70.43
80
No. Tara
61.28
70
60
24.09%
1
No. Tara
0.1731
55.18
117
1170.0
42.38
50
108.0
922.0
Peso de Tara
42.4
Peso de Tara
424.0
9.0
248.0
Peso Seco
65.6
498.0
13.72%
24.09%
40
33.84
Fecha muestreo:
24.09
27.44
0.0 865
30
20
0.0288
10
0 . 1
1.00
No.200
No.140
No.100
N o.6 0
N o.4 0
N o.3 0
1 .0
N o.2 0
N o.1 6
No.8
N o.1 0
3/8 "
3/4 "
1/2"
1"
OBSERVACIONES :
1 0
. 0
N o.4
TAMIZ
1 1/2"
2"
1 0 . 0
3"
8"
4"
1 0 0 . 0
6"
Cont. de humedad %
0
0 . 0
Las gra vas mayore s a la N 4, de acuerdo a l mue streo en campo, es de aprox ima dame nte
EJECUTO
REVISO
APROBO
Vo. Bo.
LA BORA TORISTA
29.57%
RESULTADO
CUMPLE
FECHA:
12/02/2011
FECHA :
13/02/2011
FECHA:
14/02/2011
FECHA:
15-feb
SI
CUMPLE
SI
FECHA :
15-feb
MA PA DE PELIGROS, PLA N DE USOS DEL SUELO ANTE DESASTRES Y MEDIDAS DE MITIGACIN DE EL TA MBO, HUANCAYO Y CHILCA
ANALISIS GRANULOMETRICO
Ttulo:
Fecha de revisin:
15-feb-11
CAL./mues tra
Proyecto:
ESTUDIO DE MAPA DE PELIGROS Y PLAN DE USO DE SUELOS ANTE DESASTRES Y MEDIDAS DE MITIGACION DE LA CIUDADES DE
HUANCAYO, EL TAMBO Y CHILCA
Contratante
M U N IC IP A L ID A D P R O VIN C IA L D E H UA N C A Y O
Sondaje
S10
Profundidad:
2.50
T amao
Tamiz
Mt.
Peso Reten.
Ac um ulado
07/02/2011
IN SITU
1.00
Ubicacin
PUENTE CENTENARIO
%
Retenido
%
Pas a
8"
0.0
0.00%
100.00%
6"
0.0
0.00%
100.00%
4"
0.0
0.00%
100.00%
3"
0.0
0.00%
100.00%
2"
0.0
0.00%
100.00%
1 1/2"
0.0
0.00%
100.00%
1"
0.0
0.00%
100.00%
3/4"
80.0
12.20%
87.80%
BANDEJA
3/8"
56.0
8.54%
79.27%
1170.0
1080.0
Especif ic .
424.0
No. 4
58.0
8.84%
70.43%
No. 10
60.0
9.15%
61.28%
922.0
No. 20
40.0
6.10%
55.18%
656.0
No. 40
84.0
12.80%
42.38%
No. 60
56.0
8.54%
33.84%
No. 100
42.0
6.40%
27.44%
19
LP =
17
CLASIF.(SUCS/
ASHTOO):
Tamao en mm
0.1
0.1
Cc= 1.50
Cu= 6.00
0.2
0.4
0.3
0.9
1.2
0.6
2.0
4.8
2.4
9.5
LL =
SM
IP =
D 10 =
D 30 =
D 60 =
A-1-b ( 0 )
COLOR:
0.029
0.087
0.173
MARRON
PROCEDENCIA:
87.80
90
12.7
19.0
100.00
100.00
25.4
76.2
37.5
0.00%
101.6
24.09%
24.09%
50.8
3.35%
158.0
203.2
22.0
Platillo
152.4
No. 200
100
Contenido de humedad de la f raccin de Suelo seco que pasa % de suelo seco que pasa la malla No. 200
la malla # 4 :
:
79.27
13.72%
70.43
80
No. Tara
61.28
70
60
24.09%
1
No. Tara
0.1731
55.18
1170.0
108.0
117
922.0
Peso de Tara
42.4
Peso de Tara
424.0
9.0
248.0
Peso Seco
65.6
498.0
13.72%
24.09%
50
42.38
40
33.84
Fecha muestreo:
24.09
27.44
0.0865
30
20
0.0288
10
OBSERVACIONES :
0 . 1
1.00
No.200
No.140
No.100
N o.6 0
N o.4 0
N o.3 0
1 . 0
N o.2 0
N o.1 6
No.8
N o.1 0
3/8 "
3/4 "
1"
1/2"
1 0 . 0
N o.4
TAMIZ
1 1/2"
2"
1 0 0 .0
3"
8"
4"
1 0 0 . 0
6"
Cont. de humedad %
0
0 . 0
EJECUTO
REVISO
APROBO
Vo. Bo.
LA BORA TORISTA
ROAD TECH SA C
29.57%
RESULTADO
CUMPLE
FECHA:
12/02/2011
FECHA:
13/02/2011
FECHA:
14/02/2011
FECHA :
15-feb
SI
CUMPLE
SI
FECHA :
15-feb
MA PA DE PELIGROS, PLA N DE USOS DEL SUELO ANTE DESASTRES Y MEDIDAS DE MITIGACIN DE EL TA MBO, HUANCAYO Y CHILCA
ANALISIS GRANULOMETRICO
Ttulo:
Fecha de revisin:
15-feb-11
CAL./mues tra
Proyecto:
ESTUDIO DE MAPA DE PELIGROS Y PLAN DE USO DE SUELOS ANTE DESASTRES Y MEDIDAS DE MITIGACION DE LA CIUDADES DE
HUANCAYO, EL TAMBO Y CHILCA
Contratante
M UN IC IP A L ID A D P R OV IN C IA L D E H U A N C A Y O
Sondaje
S10
Profundidad:
2.50
T amao
Tamiz
Mt.
Peso Reten.
A cumulado
07/02/2011
Muestreado por:
IN SITU
Muestra No.
1.00
Ubicacin
PUENTE CENTENARIO
%
Retenido
%
Pasa
8"
0.0
0.00%
100.00%
6"
0.0
0.00%
100.00%
4"
0.0
0.00%
100.00%
3"
0.0
0.00%
100.00%
2"
0.0
0.00%
100.00%
1 1/2"
0.0
0.00%
100.00%
1"
0.0
0.00%
100.00%
3/4"
80.0
12.20%
87.80%
BANDEJA
3/8"
56.0
8.54%
79.27%
1170.0
1080.0
Especific.
424.0
No. 4
58.0
8.84%
70.43%
No. 10
60.0
9.15%
61.28%
922.0
No. 20
40.0
6.10%
55.18%
656.0
No. 40
84.0
12.80%
42.38%
No. 60
56.0
8.54%
33.84%
No. 100
42.0
6.40%
27.44%
19
LP =
17
CLASIF.(SUCS/
ASHTOO):
Tamao en mm
0.1
0.1
Cc= 1.50
Cu= 6.00
0.2
0.4
0.3
0.9
1.2
0.6
2.0
4.8
2.4
9.5
LL =
SM
IP =
D 10 =
D 30 =
D 60 =
COLOR:
A-1-b ( 0 )
0.029
0.087
0.173
MARRON
PROCEDENCIA:
87.80
90
12.7
37.5
19.0
100.00
100.00
25.4
101.6
0.00%
76.2
24.09%
24.09%
50.8
3.35%
158.0
203.2
22.0
Platillo
152.4
No. 200
100
Contenido de humedad de la fracci n de Suelo seco que pasa % de suelo seco que pasa la malla No. 200
la malla # 4 :
:
79.27
13.72%
70.43
80
No. Tara
61.28
70
60
24.09%
1
No. Tara
0.1731
55.18
117
1170.0
42.38
50
108.0
922.0
Peso de Tara
42.4
Peso de Tara
424.0
9.0
248.0
Peso Seco
65.6
498.0
13.72%
24.09%
40
33.84
Fecha muestreo:
0.0 865
24.09
27.44
30
20
0.0288
10
0 . 1
1.00
N o.200
N o.140
N o.100
N o.60
N o.40
N o.30
1 .0
N o.20
N o.16
N o.8
N o.10
3/8"
1/2"
3/4"
1"
OBSERVACIONES :
1 0
. 0
N o.4
TAMIZ
1 1/2"
2"
1 0 . 0
3"
4"
8"
1 0 0 . 0
6"
Cont. de humedad %
0
0 . 0
Las gra vas mayore s a la N 4, de acuerdo a l mue streo en campo, es de aprox ima dame nte
EJECUTO
REVISO
APROBO
Vo. Bo.
LA BORA TORISTA
29.57%
RESULTADO
CUMPLE
FECHA:
12/02/2011
FECHA :
13/02/2011
FECHA:
14/02/2011
FECHA:
15-feb
SI
CUMPLE
SI
FECHA :
15-feb
MA PA DE PELIGROS, PLA N DE USOS DEL SUELO ANTE DESASTRES Y MEDIDAS DE MITIGACIN DE EL TA MBO, HUANCAYO Y CHILCA
ANALISIS GRANULOMETRICO
Ttulo:
Fecha de revisin:
15-feb-11
CAL./mues tra
Proyecto:
ESTUDIO DE MAPA DE PELIGROS Y PLAN DE USO DE SUELOS ANTE DESASTRES Y MEDIDAS DE MITIGACION DE LA CIUDADES DE
HUANCAYO, EL TAMBO Y CHILCA
Contratante
M UN IC IP A L ID A D P R OV IN C IA L D E H U A N C A Y O
Sondaje
S12
Profundidad:
T amao
Tamiz
3.00
Mt.
Peso Reten.
A cumulado
%
Retenido
%
Pasa
07/02/2011
Muestreado por:
IN SITU
Muestra No.
2.00
Especific.
Ubicacin
URB. EL TREBOL
8"
0.0
0.00%
100.00%
6"
0.0
0.00%
100.00%
4"
0.0
0.00%
100.00%
3"
0.0
0.00%
100.00%
2"
0.0
0.00%
100.00%
1 1/2"
0.0
0.00%
100.00%
1"
0.0
0.00%
100.00%
3/4"
0.0
0.00%
100.00%
BANDEJA
3/8"
8.0
1.23%
98.77%
1172.0
1074.0
426.0
No. 4
20.0
3.09%
95.68%
No. 10
54.0
8.33%
87.35%
660.0
No. 20
46.0
7.10%
80.25%
648.0
No. 40
46.0
7.10%
73.15%
No. 60
18.0
2.78%
70.37%
No. 100
16.0
2.47%
67.90%
24
LP =
17
0.1
0.1
Cc= 1.50
Cu= 6.00
0.2
0.4
0.3
0.9
1.2
0.6
2.0
4.8
LL =
CLASIF.(SUCS/
ASHTOO):
Tamao en mm
ML-CL
IP =
D 10 =
D 30 =
D 60 =
COLOR:
A-4 ( 6 )
0.010
0.031
0.062
MARRON
95.68
2.4
9.5
100.00
12.7
98.77
37.5
19.0
100.00
100.00
25.4
101.6
0.00%
76.2
65.74%
65.74%
50.8
2.16%
426.0
203.2
14.0
Platillo
152.4
No. 200
100
PROCEDENCIA:
87.35
90
Contenido de humedad de la fracci n de Suelo seco que pasa % de suelo seco que pasa la malla No. 200
la malla # 4 :
:
80.25
67.90
70
65.74
15.12%
70.37
73.1 5
80
Fecha muestreo:
No. Tara
65.74%
1
No. Tara
0.0617
60
117.2
1172.0
107.4
660.0
Peso de Tara
42.6
Peso de Tara
426.0
9.8
512.0
Peso Seco
64.8
234.0
15.12%
65.74%
50
40
0.0309
30
20
0.0103
10
0 . 1
1.00
N o.200
N o.140
N o.100
N o.60
N o.40
N o.30
1 .0
N o.20
N o.16
N o.8
N o.10
3/8"
1/2"
3/4"
1"
OBSERVACIONES :
1 0
. 0
N o.4
TAMIZ
1 1/2"
2"
1 0 . 0
3"
4"
8"
1 0 0 . 0
6"
Cont. de humedad %
0
0 . 0
Las gra vas mayore s a la N 4, de acuerdo a l mue streo en campo, es de aprox ima dame nte
EJECUTO
REVISO
APROBO
Vo. Bo.
LA BORA TORISTA
4.32%
RESULTADO
CUMPLE
FECHA:
12/02/2011
FECHA :
13/02/2011
FECHA:
14/02/2011
FECHA:
15-feb
SI
CUMPLE
SI
FECHA :
15-feb
MA PA DE PELIGROS, PLA N DE USOS DEL SUELO ANTE DESASTRES Y MEDIDAS DE MITIGACIN DE EL TA MBO, HUANCAYO Y CHILCA
ANALISIS GRANULOMETRICO
Ttulo:
Fecha de revisin:
15-feb-11
CAL./mues tra
Proyecto:
ESTUDIO DE MAPA DE PELIGROS Y PLAN DE USO DE SUELOS ANTE DESASTRES Y MEDIDAS DE MITIGACION DE LA CIUDADES DE
HUANCAYO, EL TAMBO Y CHILCA
Contratante
M UN IC IP A L ID A D P R OV IN C IA L D E H U A N C A Y O
Sondaje
S13
Profundidad:
T amao
Tamiz
1.50
Mt.
Peso Reten.
A cumulado
%
Retenido
%
Pasa
Fecha muestreo:
07/02/2011
Muestreado por:
IN SITU
Muestra No.
1.00
Especific.
Ubicacin
CLINICA MUNICIPAL
8"
0.0
0.00%
100.00%
6"
0.0
0.00%
100.00%
4"
0.0
0.00%
100.00%
3"
0.0
0.00%
100.00%
2"
0.0
0.00%
100.00%
1 1/2"
0.0
0.00%
100.00%
1"
0.0
0.00%
100.00%
3/4"
18.0
3.01%
96.99%
BANDEJA
3/8"
8.0
1.34%
95.65%
1136.0
1030.0
432.0
No. 4
24.0
4.01%
91.64%
No. 10
54.0
9.03%
82.61%
720.0
No. 20
52.0
8.70%
73.91%
598.0
No. 40
56.0
9.36%
64.55%
No. 60
24.0
4.01%
60.54%
No. 100
22.0
3.68%
56.86%
0.1
CLASIF.(SUCS/
ASHTOO):
Tamao en mm
0.1
0.2
0.4
0.3
0.9
1.2
0.6
2.0
4.8
2.4
9.5
12.7
96.99
22
LP =
17
Cc= 1.50
Cu= 6.00
ML-CL
IP =
D 10 =
D 30 =
D 60 =
COLOR:
A-4 ( 4 )
0.013
0.038
0.076
MARRON
91.64
95.65
37.5
19.0
100.00
100
100.00
25.4
101.6
0.00%
76.2
53.85%
53.85%
50.8
3.01%
322.0
203.2
18.0
Platillo
152.4
No. 200
LL =
PROCEDENCIA:
Contenido de humedad de la fracci n de Suelo seco que pasa % de suelo seco que pasa la malla No. 200
la malla # 4 :
:
82.6 1
90
80
73.91
17.73%
53.85%
64.55
No. Tara
60.54
No. Tara
53.85
0.0756
60
56.86
70
113.6
1136.0
103.0
720.0
Peso de Tara
43.2
Peso de Tara
432.0
10.6
416.0
Peso Seco
59.8
288.0
17.73%
53.85%
50
40
0.0378
30
20
0.0126
10
0 . 1
1.00
N o.200
N o.140
N o.100
N o.60
N o.40
N o.30
1 .0
N o.20
N o.16
N o.8
N o.10
3/8"
1/2"
3/4"
1"
OBSERVACIONES :
1 0
. 0
N o.4
TAMIZ
1 1/2"
2"
1 0 . 0
3"
4"
8"
1 0 0 . 0
6"
Cont. de humedad %
0
0 . 0
Las gra vas mayore s a la N 4, de acuerdo a l mue streo en campo, es de aprox ima dame nte
EJECUTO
REVISO
APROBO
Vo. Bo.
LA BORA TORISTA
8.36%
RESULTADO
CUMPLE
FECHA:
12/02/2011
FECHA :
13/02/2011
FECHA:
14/02/2011
FECHA:
15-feb
SI
CUMPLE
SI
FECHA :
15-feb
MA PA DE PELIGROS, PLA N DE USOS DEL SUELO ANTE DESASTRES Y MEDIDAS DE MITIGACIN DE EL TA MBO, HUANCAYO Y CHILCA
ANALISIS GRANULOMETRICO
Ttulo:
Fecha de revisin:
15-feb-11
CAL./mues tra
Proyecto:
ESTUDIO DE MAPA DE PELIGROS Y PLAN DE USO DE SUELOS ANTE DESASTRES Y MEDIDAS DE MITIGACION DE LA CIUDADES DE
HUANCAYO, EL TAMBO Y CHILCA
Contratante
M UN IC IP A L ID A D P R OV IN C IA L D E H U A N C A Y O
Sondaje
S13
Profundidad:
T amao
Tamiz
3.00
Mt.
Peso Reten.
A cumulado
%
Retenido
%
Pasa
Fecha muestreo:
07/02/2011
Muestreado por:
IN SITU
Muestra No.
2.00
Especific.
CLINICA MUNICIPAL
8"
0.0
0.00%
100.00%
6"
0.0
0.00%
100.00%
4"
0.0
0.00%
100.00%
3"
0.0
0.00%
100.00%
2"
0.0
0.00%
100.00%
1 1/2"
0.0
0.00%
100.00%
1"
0.0
0.00%
100.00%
3/4"
0.0
0.00%
100.00%
BANDEJA
3/8"
32.0
5.37%
94.63%
1132.0
1028.0
432.0
No. 4
36.0
6.04%
88.59%
No. 10
56.0
9.40%
79.19%
732.0
No. 20
50.0
8.39%
70.81%
596.0
No. 40
52.0
8.72%
62.08%
No. 60
22.0
3.69%
58.39%
No. 100
20.0
3.36%
55.03%
0.1
0.1
CLASIF.(SUCS/
ASHTOO):
Tamao en mm
LP =
17
ML-CL
IP =
D 10 =
D 30 =
D 60 =
COLOR:
A-4 ( 3 )
0.013
0.040
0.079
MARRON
PROCEDENCIA:
88.5 9
90
21
Cc= 1.50
Cu= 6.00
0.2
0.4
0.3
0.9
1.2
0.6
2.0
4.8
2.4
LL =
94.63
9.5
100.00
12.7
37.5
19.0
100.00
100.00
25.4
101.6
0.00%
76.2
51.34%
51.34%
50.8
3.69%
306.0
203.2
22.0
Platillo
152.4
No. 200
100
Contenido de humedad de la fracci n de Suelo seco que pasa % de suelo seco que pasa la malla No. 200
la malla # 4 :
:
79.19
17.45%
70.81
80
No. Tara
62.08
70
60
51.34%
1
No. Tara
0.0794
51.34
55.03
58.39
Ubicacin
50
113.2
1132.0
102.8
732.0
Peso de Tara
43.2
Peso de Tara
432.0
10.4
400.0
Peso Seco
59.6
300.0
17.45%
51.34%
40
0.0397
30
20
0.0132
10
0 . 1
1.00
N o.200
N o.140
N o.100
N o.60
N o.40
N o.30
1 .0
N o.20
N o.16
N o.8
N o.10
3/8"
1/2"
3/4"
1"
OBSERVACIONES :
1 0
. 0
N o.4
TAMIZ
1 1/2"
2"
1 0 . 0
3"
4"
8"
1 0 0 . 0
6"
Cont. de humedad %
0
0 . 0
Las gra vas mayore s a la N 4, de acuerdo a l mue streo en campo, es de aprox ima dame nte
EJECUTO
REVISO
APROBO
Vo. Bo.
LA BORA TORISTA
11.41%
RESULTADO
CUMPLE
FECHA:
12/02/2011
FECHA :
13/02/2011
FECHA:
14/02/2011
FECHA:
15-feb
SI
CUMPLE
SI
FECHA :
15-feb
MA PA DE PELIGROS, PLA N DE USOS DEL SUELO ANTE DESASTRES Y MEDIDAS DE MITIGACIN DE EL TA MBO, HUANCAYO Y CHILCA
ANALISIS GRANULOMETRICO
Ttulo:
Fecha de revisin:
15-feb-11
CAL./mues tra
Proyecto:
ESTUDIO DE MAPA DE PELIGROS Y PLAN DE USO DE SUELOS ANTE DESASTRES Y MEDIDAS DE MITIGACION DE LA CIUDADES DE
HUANCAYO, EL TAMBO Y CHILCA
Contratante
M UN IC IP A L ID A D P R OV IN C IA L D E H U A N C A Y O
Sondaje
S14
Profundidad:
1.40
Mt.
Peso Reten.
A cumulado
%
Retenido
%
Pasa
T amao
Tamiz
Fecha muestreo:
07/02/2011
Muestreado por:
IN SITU
Muestra No.
1.00
Especific.
Ubicacin
HUANCAYO
8"
0.0
0.00%
100.00%
6"
0.0
0.00%
100.00%
4"
0.0
0.00%
100.00%
3"
0.0
0.00%
100.00%
2"
0.0
0.00%
100.00%
1 1/2"
0.0
0.00%
100.00%
1"
0.0
0.00%
100.00%
3/4"
0.0
0.00%
100.00%
BANDEJA
3/8"
4.0
0.67%
99.33%
1166.0
1028.0
428.0
30.0
5.00%
81.33%
600.0
No. 40
22.0
3.67%
77.67%
No. 60
8.0
1.33%
76.33%
No. 100
4.0
0.67%
75.67%
6.0
1.00%
74.67%
448.0
74.67%
0.00%
LP =
0.1
0.1
Cc= 1.50
Cu= 6.00
0.2
0.3
1.2
0.6
2.4
9.5
LL =
CLASIF.(SUCS/
ASHTOO):
Tamao en mm
94.67
100
99.33
37.5
101.6
76.2
203.2
152.4
Platillo
50.8
No. 200
0.4
542.0
No. 20
0.9
2.0
86.33%
4.8
94.67%
8.33%
100.00
12.7
4.67%
50.0
19.0
100.00
28.0
100.00
25.4
No. 4
No. 10
ML
IP =
D 10 =
D 30 =
D 60 =
COLOR:
A-4 ( 8 )
0.009
0.027
0.054
MARRON
PROCEDENCIA:
75.6 7
74.67
Contenido de humedad de la fracci n de Suelo seco que pasa % de suelo seco que pasa la malla No. 200
la malla # 4 :
:
76.33
80
77.67
81.3 3
86.33
90
23.00%
74.67%
70
No. Tara
No. Tara
0.0542
60
116.6
1166.0
102.8
542.0
Peso de Tara
42.8
Peso de Tara
428.0
13.8
624.0
60.0
114.0
23.00%
74.67%
50
40
0.0271
30
20
Peso Seco
10
0 . 1
1.00
N o.200
N o.140
N o.100
N o.60
N o.40
N o.30
1 .0
N o.20
N o.16
N o.8
N o.10
3/8"
1/2"
3/4"
1"
OBSERVACIONES :
1 0
. 0
N o.4
TAMIZ
1 1/2"
2"
1 0 . 0
3"
8"
1 0 0 . 0
4"
6"
Cont. de humedad %
0 . 0
Las gra vas mayore s a la N 4, de acuerdo a l mue streo en campo, es de aprox ima dame nte
EJECUTO
REVISO
APROBO
Vo. Bo.
LA BORA TORISTA
5.33%
RESULTADO
CUMPLE
FECHA:
12/02/2011
FECHA :
13/02/2011
FECHA:
14/02/2011
FECHA:
15-feb
SI
CUMPLE
SI
FECHA :
15-feb
MA PA DE PELIGROS, PLA N DE USOS DEL SUELO ANTE DESASTRES Y MEDIDAS DE MITIGACIN DE EL TA MBO, HUANCAYO Y CHILCA
ANALISIS GRANULOMETRICO
Ttulo:
Fecha de revisin:
15-feb-11
CAL./mues tra
Proyecto:
ESTUDIO DE MAPA DE PELIGROS Y PLAN DE USO DE SUELOS ANTE DESASTRES Y MEDIDAS DE MITIGACION DE LA CIUDADES DE
HUANCAYO, EL TAMBO Y CHILCA
Contratante
M UN IC IP A L ID A D P R OV IN C IA L D E H U A N C A Y O
Sondaje
S14
Profundidad:
3.00
Mt.
Peso Reten.
A cumulado
%
Retenido
%
Pasa
T amao
Tamiz
Fecha muestreo:
07/02/2011
Muestreado por:
IN SITU
Muestra No.
2.00
Especific.
Ubicacin
HUANCAYO
8"
0.0
0.00%
100.00%
6"
0.0
0.00%
100.00%
4"
0.0
0.00%
100.00%
3"
0.0
0.00%
100.00%
2"
0.0
0.00%
100.00%
1 1/2"
0.0
0.00%
100.00%
1"
0.0
0.00%
100.00%
3/4"
116.0
18.13%
81.88%
BANDEJA
3/8"
94.0
14.69%
67.19%
1172.0
1062.0
422.0
No. 4
72.0
11.25%
55.94%
No. 10
66.0
10.31%
45.63%
936.0
No. 20
42.0
6.56%
39.06%
640.0
No. 40
50.0
7.81%
31.25%
No. 60
28.0
4.38%
26.88%
No. 100
24.0
3.75%
23.13%
20
LP =
17
0.1
0.2
Cc= 1.50
Cu= 6.00
0.1
0.4
0.3
0.9
1.2
0.6
2.0
4.8
2.4
9.5
12.7
37.5
19.0
100.00
100
100.00
25.4
101.6
0.00%
76.2
20.63%
20.63%
50.8
2.50%
132.0
203.2
16.0
Platillo
152.4
No. 200
LL =
CLASIF.(SUCS/
ASHTOO):
Tamao en mm
GM
IP =
D 10 =
D 30 =
D 60 =
COLOR:
A-1-b ( 0 )
0.034
0.102
0.204
MARRON
PROCEDENCIA:
90
Contenido de humedad de la fracci n de Suelo seco que pasa % de suelo seco que pasa la malla No. 200
la malla # 4 :
:
81.88
80
17.19%
20.63%
No. Tara
No. Tara
0.2036
60
55.94
117.2
1172.0
106.2
936.0
Peso de Tara
42.2
Peso de Tara
422.0
11.0
236.0
64.0
514.0
17.19%
20.63%
50
39.06
45.63
40
31.25
67.19
70
0.1018
20
20.63
23.13
26.88
30
10
0.0339
Peso Seco
0 . 1
1.00
N o.200
N o.140
N o.100
N o.60
N o.40
N o.30
1 .0
N o.20
N o.16
N o.8
N o.10
3/8"
1/2"
3/4"
1"
OBSERVACIONES :
1 0
. 0
N o.4
TAMIZ
1 1/2"
2"
1 0 . 0
3"
8"
1 0 0 . 0
4"
6"
Cont. de humedad %
0 . 0
Las gra vas mayore s a la N 4, de acuerdo a l mue streo en campo, es de aprox ima dame nte
EJECUTO
REVISO
APROBO
Vo. Bo.
LA BORA TORISTA
44.06%
RESULTADO
CUMPLE
FECHA:
12/02/2011
FECHA :
13/02/2011
FECHA:
14/02/2011
FECHA:
15-feb
SI
CUMPLE
SI
FECHA :
15-feb
MA PA DE PELIGROS, PLA N DE USOS DEL SUELO ANTE DESASTRES Y MEDIDAS DE MITIGACIN DE EL TA MBO, HUANCAYO Y CHILCA
ANALISIS GRANULOMETRICO
Ttulo:
Fecha de revisin:
15-feb-11
CAL./mues tra
Proyecto:
ESTUDIO DE MAPA DE PELIGROS Y PLAN DE USO DE SUELOS ANTE DESASTRES Y MEDIDAS DE MITIGACION DE LA CIUDADES DE
HUANCAYO, EL TAMBO Y CHILCA
Contratante
M UN IC IP A L ID A D P R OV IN C IA L D E H U A N C A Y O
Sondaje
S15
Profundidad:
T amao
Tamiz
1.00
Mt.
Peso Reten.
A cumulado
%
Retenido
%
Pasa
Fecha muestreo:
07/02/2011
Muestreado por:
IN SITU
Muestra No.
1.00
Especific.
Ubicacin
HUANCAYO
8"
0.0
0.00%
100.00%
6"
0.0
0.00%
100.00%
4"
0.0
0.00%
100.00%
3"
0.0
0.00%
100.00%
2"
0.0
0.00%
100.00%
1 1/2"
0.0
0.00%
100.00%
1"
0.0
0.00%
100.00%
3/4"
0.0
0.00%
100.00%
BANDEJA
428.0
3/8"
34.0
6.75%
93.25%
986.0
No. 4
70.0
13.89%
79.37%
932.0
No. 10
102.0
20.24%
59.13%
826.0
No. 20
56.0
11.11%
48.02%
504.0
No. 40
60.0
11.90%
36.11%
No. 60
32.0
6.35%
29.76%
No. 100
26.0
5.16%
24.60%
0.1
0.1
0.2
0.4
0.3
0.9
1.2
0.6
2.0
4.8
2.4
LP =
Cc= 1.50
Cu= 6.00
CLASIF.(SUCS/
ASHTOO):
Tamao en mm
93.25
9.5
100.00
12.7
37.5
19.0
100.00
100
100.00
25.4
101.6
0.00%
76.2
22.22%
22.22%
50.8
2.38%
112.0
203.2
12.0
Platillo
152.4
No. 200
LL =
SM
IP =
D 10 =
D 30 =
D 60 =
COLOR:
A-1-b ( 0 )
0.031
0.094
0.188
MARRON
PROCEDENCIA:
90
Contenido de humedad de la fracci n de Suelo seco que pasa % de suelo seco que pasa la malla No. 200
la malla # 4 :
:
79.37
80
10.71%
22.22%
No. Tara
59.13
60
No. Tara
0.1883
50
98.6
986.0
93.2
826.0
Peso de Tara
42.8
Peso de Tara
428.0
5.4
160.0
Peso Seco
50.4
398.0
10.71%
22.22%
48.02
40
29.76
36.11
70
24.60
22.22
0.0941
30
20
0.0314
10
0 . 1
1.00
N o.200
N o.140
N o.100
N o.60
N o.40
N o.30
1 .0
N o.20
N o.16
N o.8
N o.10
3/8"
1/2"
3/4"
1"
OBSERVACIONES :
1 0
. 0
N o.4
TAMIZ
1 1/2"
2"
1 0 . 0
3"
4"
8"
1 0 0 . 0
6"
Cont. de humedad %
0
0 . 0
Las gra vas mayore s a la N 4, de acuerdo a l mue streo en campo, es de aprox ima dame nte
EJECUTO
REVISO
APROBO
Vo. Bo.
LA BORA TORISTA
20.63%
RESULTADO
CUMPLE
FECHA:
12/02/2011
FECHA :
13/02/2011
FECHA:
14/02/2011
FECHA:
15-feb
SI
CUMPLE
SI
FECHA :
15-feb
MA PA DE PELIGROS, PLA N DE USOS DEL SUELO ANTE DESASTRES Y MEDIDAS DE MITIGACIN DE EL TA MBO, HUANCAYO Y CHILCA
ANALISIS GRANULOMETRICO
Ttulo:
Fecha de revisin:
15-feb-11
CAL./mues tra
Proyecto:
ESTUDIO DE MAPA DE PELIGROS Y PLAN DE USO DE SUELOS ANTE DESASTRES Y MEDIDAS DE MITIGACION DE LA CIUDADES DE
HUANCAYO, EL TAMBO Y CHILCA
Contratante
M UN IC IP A L ID A D P R OV IN C IA L D E H U A N C A Y O
Sondaje
S15
Profundidad:
T amao
Tamiz
2.00
Mt.
Peso Reten.
A cumulado
%
Retenido
%
Pasa
Fecha muestreo:
07/02/2011
Muestreado por:
IN SITU
Muestra No.
2.00
Especific.
Ubicacin
HUANCAYO
8"
0.0
0.00%
100.00%
6"
0.0
0.00%
100.00%
4"
0.0
0.00%
100.00%
3"
0.0
0.00%
100.00%
2"
0.0
0.00%
100.00%
1 1/2"
0.0
0.00%
100.00%
1"
0.0
0.00%
100.00%
3/4"
0.0
0.00%
100.00%
BANDEJA
3/8"
16.0
1.03%
98.97%
1186.0
1986.0
432.0
1.42%
93.56%
No. 40
22.0
1.42%
92.15%
No. 60
12.0
0.77%
91.38%
No. 100
16.0
1.03%
90.35%
14.0
0.90%
89.45%
1390.0
89.45%
0.00%
602.0
1554.0
24
LP =
17
0.1
CLASIF.(SUCS/
ASHTOO):
Tamao en mm
ML-CL
IP =
D 10 =
D 30 =
D 60 =
COLOR:
A-4 ( 8 )
0.008
0.023
0.045
MARRON
PROCEDENCIA:
89.45
90.35
0.1
Cc= 1.50
Cu= 6.00
0.2
0.3
92.15
90
LL =
91.38
1.2
0.6
93.56
94.98
9.5
2.4
98.07
100
98.97
101.6
76.2
203.2
152.4
Platillo
50.8
No. 200
0.4
22.0
0.9
No. 20
2.0
4.8
94.98%
100.00
12.7
98.07%
3.09%
37.5
0.90%
48.0
19.0
100.00
14.0
100.00
25.4
No. 4
No. 10
Contenido de humedad de la fracci n de Suelo seco que pasa % de suelo seco que pasa la malla No. 200
la malla # 4 :
:
80
-51.48%
89.45%
70
No. Tara
No. Tara
0.0452
60
118.6
1186.0
198.6
602.0
Peso de Tara
43.2
Peso de Tara
432.0
-80.0
584.0
Peso Seco
155.4
170.0
-51.48%
89.45%
50
40
0.0226
30
20
10
0 . 1
1.00
N o.200
N o.140
N o.100
N o.60
N o.40
N o.30
1 .0
N o.20
N o.16
N o.8
N o.10
3/8"
1/2"
3/4"
1"
OBSERVACIONES :
1 0
. 0
N o.4
TAMIZ
1 1/2"
2"
1 0 . 0
3"
4"
8"
1 0 0 . 0
6"
Cont. de humedad %
0
0 . 0
Las gra vas mayore s a la N 4, de acuerdo a l mue streo en campo, es de aprox ima dame nte
EJECUTO
REVISO
APROBO
Vo. Bo.
LA BORA TORISTA
1.93%
RESULTADO
CUMPLE
FECHA:
12/02/2011
FECHA :
13/02/2011
FECHA:
14/02/2011
FECHA:
15-feb
SI
CUMPLE
SI
FECHA :
15-feb
MA PA DE PELIGROS, PLA N DE USOS DEL SUELO ANTE DESASTRES Y MEDIDAS DE MITIGACIN DE EL TA MBO, HUANCAYO Y CHILCA
ANALISIS GRANULOMETRICO
Ttulo:
Fecha de revisin:
15-feb-11
CAL./mues tra
Proyecto:
ESTUDIO DE MAPA DE PELIGROS Y PLAN DE USO DE SUELOS ANTE DESASTRES Y MEDIDAS DE MITIGACION DE LA CIUDADES DE
HUANCAYO, EL TAMBO Y CHILCA
Contratante
M UN IC IP A L ID A D P R OV IN C IA L D E H U A N C A Y O
Sondaje
S15
Profundidad:
3.00
T amao
Tamiz
Mt.
Peso Reten.
A cumulado
Fecha muestreo:
07/02/2011
Muestreado por:
IN SITU
Muestra No.
3.00
Ubicacin
HUANCAYO
%
Retenido
%
Pasa
8"
0.0
0.00%
100.00%
6"
0.0
0.00%
100.00%
4"
0.0
0.00%
100.00%
3"
0.0
0.00%
100.00%
2"
0.0
0.00%
100.00%
1 1/2"
0.0
0.00%
100.00%
1"
0.0
0.00%
100.00%
3/4"
0.0
0.00%
100.00%
BANDEJA
3/8"
16.0
2.57%
97.43%
1212.0
1044.0
Especific.
422.0
16.0
2.57%
83.60%
622.0
No. 40
14.0
2.25%
81.35%
No. 60
6.0
0.96%
80.39%
No. 100
6.0
0.96%
79.42%
6.0
0.96%
78.46%
488.0
78.46%
0.00%
0.1
0.1
0.2
0.3
1.2
0.6
2.4
9.5
LP =
16
CLASIF.(SUCS/
ASHTOO):
Tamao en mm
CL
IP =
D 10 =
D 30 =
D 60 =
A-4 ( 8 )
COLOR:
10
0.009
0.026
0.052
MARRON
PROCEDENCIA:
Contenido de humedad de la fracci n de Suelo seco que pasa % de suelo seco que pasa la malla No. 200
la malla # 4 :
:
78.46
79.42
80
80.39
81.35
83.60
86.17
90
26
Cc= 1.50
Cu= 6.00
91.32
100
LL =
97.43
76.2
37.5
101.6
203.2
152.4
Platillo
50.8
No. 200
0.4
560.0
No. 20
0.9
2.0
86.17%
4.8
91.32%
5.14%
100.00
12.7
6.11%
32.0
19.0
100.00
38.0
100.00
25.4
No. 4
No. 10
27.01%
78.46%
70
No. Tara
60
No. Tara
0.0516
121.2
1212.0
104.4
560.0
Peso de Tara
42.2
Peso de Tara
422.0
16.8
652.0
Peso Seco
62.2
138.0
27.01%
78.46%
50
40
0.0258
30
20
10
0 . 1
1.00
No.200
No.140
No.100
N o.6 0
N o.4 0
N o.3 0
1 .0
N o.2 0
N o.1 6
No.8
N o.1 0
3/8 "
3/4 "
1/2"
1"
OBSERVACIONES :
1 0
. 0
N o.4
TAMIZ
1 1/2"
2"
1 0 . 0
3"
8"
4"
1 0 0 . 0
6"
Cont. de humedad %
0
0 . 0
Las gra vas mayore s a la N 4, de acuerdo a l mue streo en campo, es de aprox ima dame nte
EJECUTO
REVISO
APROBO
Vo. Bo.
LA BORA TORISTA
8.68%
RESULTADO
CUMPLE
FECHA:
12/02/2011
FECHA :
13/02/2011
FECHA:
14/02/2011
FECHA:
15-feb
SI
CUMPLE
SI
FECHA :
15-feb
MA PA DE PELIGROS, PLA N DE USOS DEL SUELO ANTE DESASTRES Y MEDIDAS DE MITIGACIN DE EL TA MBO, HUANCAYO Y CHILCA
ANALISIS GRANULOMETRICO
Ttulo:
Fecha de revisin:
15-feb-11
CAL./mues tra
Proyecto:
ESTUDIO DE MAPA DE PELIGROS Y PLAN DE USO DE SUELOS ANTE DESASTRES Y MEDIDAS DE MITIGACION DE LA CIUDADES DE
HUANCAYO, EL TAMBO Y CHILCA
Contratante
M UN IC IP A L ID A D P R OV IN C IA L D E H U A N C A Y O
Sondaje
S16
Profundidad:
T amao
Tamiz
1.50
Mt.
Peso Reten.
A cumulado
%
Retenido
%
Pasa
Fecha muestreo:
07/02/2011
Muestreado por:
IN SITU
Muestra No.
1.00
Especific.
Ubicacin
HUANCAYO
8"
0.0
0.00%
100.00%
6"
0.0
0.00%
100.00%
4"
0.0
0.00%
100.00%
3"
0.0
0.00%
100.00%
2"
0.0
0.00%
100.00%
1 1/2"
0.0
0.00%
100.00%
1"
0.0
0.00%
100.00%
3/4"
0.0
0.00%
100.00%
BANDEJA
3/8"
66.0
9.91%
90.09%
1156.0
1094.0
428.0
No. 4
70.0
10.51%
79.58%
No. 10
96.0
14.41%
65.17%
850.0
No. 20
66.0
9.91%
55.26%
666.0
No. 40
56.0
8.41%
46.85%
No. 60
24.0
3.60%
43.24%
No. 100
20.0
3.00%
40.24%
0.1
0.1
0.2
0.4
0.3
0.9
1.2
0.6
2.0
4.8
2.4
CLASIF.(SUCS/
ASHTOO):
Tamao en mm
LP =
17
SC
IP =
D 10 =
D 30 =
D 60 =
COLOR:
A-4 ( 1 )
10
0.018
0.054
0.108
MARRON
PROCEDENCIA:
Contenido de humedad de la fracci n de Suelo seco que pasa % de suelo seco que pasa la malla No. 200
la malla # 4 :
:
79.58
90
27
Cc= 1.50
Cu= 6.00
90.09
9.5
100.00
12.7
37.5
19.0
100.00
100
100.00
25.4
101.6
0.00%
76.2
37.84%
37.84%
50.8
2.40%
252.0
203.2
16.0
Platillo
152.4
No. 200
LL =
80
9.31%
37.84%
65.17
No. Tara
No. Tara
0.1085
60
55.26
115.6
1156.0
109.4
850.0
Peso de Tara
42.8
Peso de Tara
428.0
6.2
306.0
Peso Seco
66.6
422.0
9.31%
37.84%
40.24
40
37.84
46.85
50
43.24
70
0.0542
30
20
0.0181
10
0 . 1
1.00
N o.200
N o.140
N o.100
N o.60
N o.40
N o.30
1 .0
N o.20
N o.16
N o.8
N o.10
3/8"
1/2"
3/4"
1"
OBSERVACIONES :
1 0
. 0
N o.4
TAMIZ
1 1/2"
2"
1 0 . 0
3"
4"
8"
1 0 0 . 0
6"
Cont. de humedad %
0
0 . 0
Las gra vas mayore s a la N 4, de acuerdo a l mue streo en campo, es de aprox ima dame nte
EJECUTO
REVISO
APROBO
Vo. Bo.
LA BORA TORISTA
20.42%
RESULTADO
CUMPLE
FECHA:
12/02/2011
FECHA :
13/02/2011
FECHA:
14/02/2011
FECHA:
15-feb
SI
CUMPLE
SI
FECHA :
15-feb
MA PA DE PELIGROS, PLA N DE USOS DEL SUELO ANTE DESASTRES Y MEDIDAS DE MITIGACIN DE EL TA MBO, HUANCAYO Y CHILCA
ANALISIS GRANULOMETRICO
Ttulo:
Fecha de revisin:
15-feb-11
CAL./mues tra
Proyecto:
ESTUDIO DE MAPA DE PELIGROS Y PLAN DE USO DE SUELOS ANTE DESASTRES Y MEDIDAS DE MITIGACION DE LA CIUDADES DE
HUANCAYO, EL TAMBO Y CHILCA
Contratante
M UN IC IP A L ID A D P R OV IN C IA L D E H U A N C A Y O
Sondaje
S16
Profundidad:
3.00
Mt.
Peso Reten.
A cumulado
%
Retenido
%
Pasa
T amao
Tamiz
Fecha muestreo:
07/02/2011
Muestreado por:
IN SITU
Muestra No.
2.00
Especific.
Ubicacin
HUANCAYO
8"
0.0
0.00%
100.00%
6"
0.0
0.00%
100.00%
4"
0.0
0.00%
100.00%
3"
0.0
0.00%
100.00%
2"
0.0
0.00%
100.00%
1 1/2"
0.0
0.00%
100.00%
1"
0.0
0.00%
100.00%
3/4"
20.0
3.30%
96.70%
BANDEJA
3/8"
66.0
10.89%
85.81%
1176.0
1030.0
424.0
No. 4
58.0
9.57%
76.24%
No. 10
72.0
11.88%
64.36%
768.0
No. 20
40.0
6.60%
57.76%
606.0
No. 40
38.0
6.27%
51.49%
No. 60
16.0
2.64%
48.84%
No. 100
14.0
2.31%
46.53%
0.1
0.1
0.2
0.4
0.3
0.9
1.2
0.6
2.0
4.8
2.4
9.5
12.7
19
LP =
17
Cc= 1.50
Cu= 6.00
CLASIF.(SUCS/
ASHTOO):
Tamao en mm
SM
IP =
D 10 =
D 30 =
D 60 =
COLOR:
A-4 ( 2 )
0.015
0.046
0.092
MARRON
96.70
37.5
19.0
100.00
100
100.00
25.4
101.6
0.00%
76.2
44.55%
44.55%
50.8
1.98%
270.0
203.2
12.0
Platillo
152.4
No. 200
LL =
PROCEDENCIA:
85.81
90
Contenido de humedad de la fracci n de Suelo seco que pasa % de suelo seco que pasa la malla No. 200
la malla # 4 :
:
76.24
80
24.09%
44.55%
64.36
No. Tara
No. Tara
51.49
48.8 4
50
44.55
0.0917
46.53
60
57.76
70
117.6
1176.0
103.0
768.0
Peso de Tara
42.4
Peso de Tara
424.0
14.6
408.0
Peso Seco
60.6
344.0
24.09%
44.55%
40
0.0459
30
20
0.0153
10
0 . 1
1.00
N o.200
N o.140
N o.100
N o.60
N o.40
N o.30
1 .0
N o.20
N o.16
N o.8
N o.10
3/8"
1/2"
3/4"
1"
OBSERVACIONES :
1 0
. 0
N o.4
TAMIZ
1 1/2"
2"
1 0 . 0
3"
4"
8"
1 0 0 . 0
6"
Cont. de humedad %
0
0 . 0
Las gra vas mayore s a la N 4, de acuerdo a l mue streo en campo, es de aprox ima dame nte
EJECUTO
REVISO
APROBO
Vo. Bo.
LA BORA TORISTA
23.76%
RESULTADO
CUMPLE
FECHA:
12/02/2011
FECHA :
13/02/2011
FECHA:
14/02/2011
FECHA:
15-feb
SI
CUMPLE
SI
FECHA :
15-feb
MA PA DE PELIGROS, PLA N DE USOS DEL SUELO ANTE DESASTRES Y MEDIDAS DE MITIGACIN DE EL TA MBO, HUANCAYO Y CHILCA
ANALISIS GRANULOMETRICO
Ttulo:
Fecha de revisin:
15-feb-11
CAL./mues tra
Proyecto:
ESTUDIO DE MAPA DE PELIGROS Y PLAN DE USO DE SUELOS ANTE DESASTRES Y MEDIDAS DE MITIGACION DE LA CIUDADES DE
HUANCAYO, EL TAMBO Y CHILCA
Contratante
M UN IC IP A L ID A D P R OV IN C IA L D E H U A N C A Y O
Sondaje
S17
Profundidad:
T amao
Tamiz
1.30
Mt.
Peso Reten.
A cumulado
%
Retenido
%
Pasa
Fecha muestreo:
07/02/2011
Muestreado por:
IN SITU
Muestra No.
1.00
Especific.
Ubicacin
HUANCAYO
8"
0.0
0.00%
100.00%
6"
0.0
0.00%
100.00%
4"
0.0
0.00%
100.00%
3"
0.0
0.00%
100.00%
2"
0.0
0.00%
100.00%
1 1/2"
0.0
0.00%
100.00%
1"
0.0
0.00%
100.00%
3/4"
30.0
4.79%
95.21%
BANDEJA
3/8"
82.0
13.10%
82.11%
1118.0
430.0
3.51%
10.54%
No. 60
6.0
0.96%
9.58%
No. 100
6.0
0.96%
8.63%
No. 200
8.0
1.28%
7.35%
Platillo
46.0
7.35%
0.00%
17
LP =
16
0.1
0.1
Cc= 1.50
Cu= 6.00
0.2
0.3
1.2
0.6
2.4
9.5
LL =
626.0
CLASIF.(SUCS/
ASHTOO):
Tamao en mm
GP-GM
IP =
D 10 =
D 30 =
D 60 =
COLOR:
A-1-a(0)
0.105
0.315
0.629
MARRON
95.2 1
100
0.4
22.0
0.9
No. 40
2.0
4.8
14.06%
12.7
8.95%
37.5
56.0
19.0
100.00
1024.0
No. 20
100.00
25.4
1056.0
101.6
23.00%
76.2
55.91%
32.91%
50.8
26.20%
206.0
203.2
164.0
152.4
No. 4
No. 10
PROCEDENCIA:
90
Contenido de humedad de la fracci n de Suelo seco que pasa % de suelo seco que pasa la malla No. 200
la malla # 4 :
:
82.11
80
9.90%
7.35%
No. Tara
No. Tara
0.6295
60
55.91
70
111.8
1118.0
105.6
1024.0
Peso de Tara
43.0
Peso de Tara
430.0
6.2
94.0
Peso Seco
62.6
594.0
9.90%
7.35%
50
40
0.3147
23.00
30
Cont. de humedad %
1.00
8.63
0 . 1
N o.200
N o.140
N o.100
0.1049
7.35
9.58
10.54
N o.40
N o.30
1 .0
N o.20
N o.16
N o.8
N o.10
3/8"
1/2"
3/4"
1"
OBSERVACIONES :
1 0
. 0
N o.4
TAMIZ
1 1/2"
2"
1 0 . 0
3"
8"
1 0 0 . 0
4"
6"
10
N o.60
14.06
20
0 . 0
Las gra vas mayore s a la N 4, de acuerdo a l mue streo en campo, es de aprox ima dame nte
EJECUTO
REVISO
APROBO
Vo. Bo.
LA BORA TORISTA
44.09%
RESULTADO
CUMPLE
FECHA:
12/02/2011
FECHA :
13/02/2011
FECHA:
14/02/2011
FECHA:
15-feb
SI
CUMPLE
SI
FECHA :
15-feb
MA PA DE PELIGROS, PLA N DE USOS DEL SUELO ANTE DESASTRES Y MEDIDAS DE MITIGACIN DE EL TA MBO, HUANCAYO Y CHILCA
ANALISIS GRANULOMETRICO
Ttulo:
Fecha de revisin:
15-feb-11
CAL./mues tra
Proyecto:
ESTUDIO DE MAPA DE PELIGROS Y PLAN DE USO DE SUELOS ANTE DESASTRES Y MEDIDAS DE MITIGACION DE LA CIUDADES DE
HUANCAYO, EL TAMBO Y CHILCA
Contratante
M UN IC IP A L ID A D P R OV IN C IA L D E H U A N C A Y O
Sondaje
S17
Profundidad:
T amao
Tamiz
3.00
Mt.
Peso Reten.
A cumulado
%
Retenido
%
Pasa
07/02/2011
Muestreado por:
IN SITU
Muestra No.
2.00
Especific.
Ubicacin
HUANCAYO
8"
0.0
0.00%
100.00%
6"
0.0
0.00%
100.00%
4"
0.0
0.00%
100.00%
3"
0.0
0.00%
100.00%
2"
0.0
0.00%
100.00%
1 1/2"
0.0
0.00%
100.00%
1"
0.0
0.00%
100.00%
3/4"
62.0
11.52%
88.48%
BANDEJA
3/8"
14.0
2.60%
85.87%
426.0
1102.0
No. 4
34.0
6.32%
79.55%
964.0
No. 10
48.0
8.92%
70.63%
704.0
No. 20
38.0
7.06%
63.57%
538.0
No. 40
34.0
6.32%
57.25%
No. 60
14.0
2.60%
54.65%
No. 100
12.0
2.23%
52.42%
21
LP =
17
0.1
0.1
Cc= 1.50
Cu= 6.00
0.2
0.4
0.3
0.9
1.2
0.6
2.0
4.8
2.4
9.5
LL =
CLASIF.(SUCS/
ASHTOO):
Tamao en mm
SM-SC
IP =
D 10 =
D 30 =
D 60 =
COLOR:
A-4 ( 3 )
0.014
0.041
0.082
MARRON
PROCEDENCIA:
85.87
88.48
90
12.7
37.5
19.0
100.00
100.00
25.4
101.6
0.00%
76.2
49.81%
49.81%
50.8
2.60%
268.0
203.2
14.0
Platillo
152.4
No. 200
100
Contenido de humedad de la fracci n de Suelo seco que pasa % de suelo seco que pasa la malla No. 200
la malla # 4 :
:
79.55
25.65%
70.63
80
63.57
70
No. Tara
49.81%
1
No. Tara
0.0819
52.42
50
110.2
1102.0
96.4
704.0
Peso de Tara
42.6
Peso de Tara
426.0
13.8
398.0
Peso Seco
53.8
278.0
25.65%
49.81%
49.81
57.25
60
54.65
Fecha muestreo:
40
0.0409
30
20
0.0136
10
0 . 1
1.00
N o.200
N o.140
N o.100
N o.60
N o.40
N o.30
1 .0
N o.20
N o.16
N o.8
N o.10
3/8"
1/2"
3/4"
1"
OBSERVACIONES :
1 0
. 0
N o.4
TAMIZ
1 1/2"
2"
1 0 . 0
3"
4"
8"
1 0 0 . 0
6"
Cont. de humedad %
0
0 . 0
Las gra vas mayore s a la N 4, de acuerdo a l mue streo en campo, es de aprox ima dame nte
EJECUTO
REVISO
APROBO
Vo. Bo.
LA BORA TORISTA
20.45%
RESULTADO
CUMPLE
FECHA:
12/02/2011
FECHA :
13/02/2011
FECHA:
14/02/2011
FECHA:
15-feb
SI
CUMPLE
SI
FECHA :
15-feb
MA PA DE PELIGROS, PLA N DE USOS DEL SUELO ANTE DESASTRES Y MEDIDAS DE MITIGACIN DE EL TA MBO, HUANCAYO Y CHILCA
ANALISIS GRANULOMETRICO
Ttulo:
Fecha de revisin:
15-feb-11
CAL./mues tra
Proyecto:
ESTUDIO DE MAPA DE PELIGROS Y PLAN DE USO DE SUELOS ANTE DESASTRES Y MEDIDAS DE MITIGACION DE LA CIUDADES DE
HUANCAYO, EL TAMBO Y CHILCA
Contratante
M UN IC IP A L ID A D P R OV IN C IA L D E H U A N C A Y O
Sondaje
S18
Profundidad:
2.00
Mt.
Peso Reten.
A cumulado
%
Retenido
%
Pasa
T amao
Tamiz
Fecha muestreo:
07/02/2011
Muestreado por:
IN SITU
Muestra No.
1.00
Especific.
HUANCAYO
8"
0.0
0.00%
100.00%
6"
0.0
0.00%
100.00%
4"
0.0
0.00%
100.00%
3"
0.0
0.00%
100.00%
2"
0.0
0.00%
100.00%
1 1/2"
0.0
0.00%
100.00%
1"
0.0
0.00%
100.00%
3/4"
8.0
1.27%
98.73%
BANDEJA
3/8"
16.0
2.55%
96.18%
1154.0
1056.0
428.0
No. 4
30.0
4.78%
91.40%
No. 10
46.0
7.32%
84.08%
664.0
No. 20
36.0
5.73%
78.34%
628.0
No. 40
40.0
6.37%
71.97%
No. 60
18.0
2.87%
69.11%
No. 100
14.0
2.23%
66.88%
21
LP =
18
0.1
0.1
Cc= 1.50
Cu= 6.00
0.2
0.4
0.3
0.9
1.2
0.6
2.0
4.8
2.4
9.5
98.73 12.7
LL =
CLASIF.(SUCS/
ASHTOO):
Tamao en mm
ML
IP =
D 10 =
D 30 =
D 60 =
COLOR:
A-4 ( 6 )
0.010
0.031
0.063
MARRON
96.18
37.5
PROCEDENCIA:
91.40
19.0
100.00
100.00
25.4
101.6
0.00%
76.2
64.65%
64.65%
50.8
2.23%
406.0
203.2
14.0
Platillo
152.4
No. 200
100
Contenido de humedad de la fracci n de Suelo seco que pasa % de suelo seco que pasa la malla No. 200
la malla # 4 :
:
84.08
90
78.34
80
66.88
64.65
71.97
15.61%
69.11
70
Ubicacin
No. Tara
64.65%
1
No. Tara
0.0628
60
115.4
1154.0
105.6
664.0
Peso de Tara
42.8
Peso de Tara
428.0
9.8
490.0
Peso Seco
62.8
236.0
15.61%
64.65%
50
40
0.0314
30
20
0.0105
10
0 . 1
1.00
N o.200
N o.140
N o.100
N o.60
N o.40
N o.30
1 .0
N o.20
N o.16
N o.8
N o.10
3/8"
1/2"
3/4"
1"
OBSERVACIONES :
1 0
. 0
N o.4
TAMIZ
1 1/2"
2"
1 0 . 0
3"
4"
8"
1 0 0 . 0
6"
Cont. de humedad %
0
0 . 0
Las gra vas mayore s a la N 4, de acuerdo a l mue streo en campo, es de aprox ima dame nte
EJECUTO
REVISO
APROBO
Vo. Bo.
LA BORA TORISTA
8.60%
RESULTADO
CUMPLE
FECHA:
12/02/2011
FECHA :
13/02/2011
FECHA:
14/02/2011
FECHA:
15-feb
SI
CUMPLE
SI
FECHA :
15-feb
MA PA DE PELIGROS, PLA N DE USOS DEL SUELO ANTE DESASTRES Y MEDIDAS DE MITIGACIN DE EL TA MBO, HUANCAYO Y CHILCA
ANALISIS GRANULOMETRICO
Ttulo:
Fecha de revisin:
15-feb-11
CAL./mues tra
Proyecto:
ESTUDIO DE MAPA DE PELIGROS Y PLAN DE USO DE SUELOS ANTE DESASTRES Y MEDIDAS DE MITIGACION DE LA CIUDADES DE
HUANCAYO, EL TAMBO Y CHILCA
Contratante
M UN IC IP A L ID A D P R OV IN C IA L D E H U A N C A Y O
Sondaje
S18
Profundidad:
3.00
Mt.
Peso Reten.
A cumulado
%
Retenido
%
Pasa
T amao
Tamiz
Fecha muestreo:
07/02/2011
Muestreado por:
IN SITU
Muestra No.
2.00
Especific.
Ubicacin
HUANCAYO
8"
0.0
0.00%
100.00%
6"
0.0
0.00%
100.00%
4"
0.0
0.00%
100.00%
3"
0.0
0.00%
100.00%
2"
0.0
0.00%
100.00%
1 1/2"
0.0
0.00%
100.00%
1"
0.0
0.00%
100.00%
3/4"
40.0
6.17%
93.83%
BANDEJA
3/8"
50.0
7.72%
86.11%
1158.0
1080.0
432.0
No. 4
70.0
10.80%
75.31%
No. 10
74.0
11.42%
63.89%
866.0
No. 20
48.0
7.41%
56.48%
648.0
No. 40
62.0
9.57%
46.91%
No. 60
34.0
5.25%
41.67%
No. 100
24.0
3.70%
37.96%
0.1
0.2
0.1
0.4
0.3
0.9
1.2
0.6
2.0
4.8
2.4
20
LP =
17
Cc= 1.50
Cu= 6.00
CLASIF.(SUCS/
ASHTOO):
Tamao en mm
93.83
9.5
12.7
37.5
19.0
100.00
100
100.00
25.4
101.6
0.00%
76.2
34.57%
34.57%
50.8
3.40%
224.0
203.2
22.0
Platillo
152.4
No. 200
LL =
SM
IP =
D 10 =
D 30 =
D 60 =
COLOR:
A-2-4 ( 0 )
0.020
0.060
0.119
MARRON
PROCEDENCIA:
86.11
90
Contenido de humedad de la fracci n de Suelo seco que pasa % de suelo seco que pasa la malla No. 200
la malla # 4 :
:
75.31
80
12.04%
34.57%
63.89
No. Tara
No. Tara
0.1190
60
56.48
115.8
1158.0
108.0
866.0
Peso de Tara
43.2
Peso de Tara
432.0
7.8
292.0
Peso Seco
64.8
434.0
12.04%
34.57%
37.96
40
34.57
46.91
50
41.67
70
0.0595
30
20
0.0198
10
0 . 1
1.00
N o.200
N o.140
N o.100
N o.60
N o.40
N o.30
1 .0
N o.20
N o.16
N o.8
N o.10
3/8"
1/2"
3/4"
1"
OBSERVACIONES :
1 0
. 0
N o.4
TAMIZ
1 1/2"
2"
1 0 . 0
3"
4"
8"
1 0 0 . 0
6"
Cont. de humedad %
0
0 . 0
Las gra vas mayore s a la N 4, de acuerdo a l mue streo en campo, es de aprox ima dame nte
EJECUTO
REVISO
APROBO
Vo. Bo.
LA BORA TORISTA
24.69%
RESULTADO
CUMPLE
FECHA:
12/02/2011
FECHA :
13/02/2011
FECHA:
14/02/2011
FECHA:
15-feb
SI
CUMPLE
SI
FECHA :
15-feb
MA PA DE PELIGROS, PLA N DE USOS DEL SUELO ANTE DESASTRES Y MEDIDAS DE MITIGACIN DE EL TA MBO, HUANCAYO Y CHILCA
ANALISIS GRANULOMETRICO
Ttulo:
Fecha de revisin:
15-feb-11
CAL./mues tra
Proyecto:
ESTUDIO DE MAPA DE PELIGROS Y PLAN DE USO DE SUELOS ANTE DESASTRES Y MEDIDAS DE MITIGACION DE LA CIUDADES DE
HUANCAYO, EL TAMBO Y CHILCA
Contratante
M UN IC IP A L ID A D P R OV IN C IA L D E H U A N C A Y O
Sondaje
S19
Profundidad:
T amao
Tamiz
1.00
Mt.
Peso Reten.
A cumulado
%
Retenido
%
Pasa
Fecha muestreo:
07/02/2011
Muestreado por:
IN SITU
Muestra No.
1.00
Especific.
HUANCAYO
8"
0.0
0.00%
100.00%
6"
0.0
0.00%
100.00%
4"
0.0
0.00%
100.00%
3"
0.0
0.00%
100.00%
2"
0.0
0.00%
100.00%
1 1/2"
0.0
0.00%
100.00%
1"
0.0
0.00%
100.00%
3/4"
14.0
2.30%
97.70%
BANDEJA
3/8"
14.0
2.30%
95.39%
1128.0
1034.0
426.0
30.0
4.93%
77.96%
608.0
No. 40
54.0
8.88%
69.08%
No. 60
46.0
7.57%
61.51%
No. 100
26.0
4.28%
57.24%
8.0
1.32%
55.92%
340.0
55.92%
0.00%
0.1
CLASIF.(SUCS/
ASHTOO):
Tamao en mm
0.1
0.2
0.3
1.2
0.6
2.4
9.5
19
LP =
17
Cc= 1.50
Cu= 6.00
ML
IP =
D 10 =
D 30 =
D 60 =
COLOR:
A-4 ( 4 )
0.012
0.036
0.073
MARRON
PROCEDENCIA:
89.47
100
LL =
95.39
37.5
101.6
76.2
50.8
203.2
152.4
Platillo
0.4
724.0
No. 20
0.9
2.0
82.89%
4.8
89.47%
6.58%
97.70 12.7
5.92%
40.0
19.0
100.00
36.0
100.00
25.4
No. 4
No. 10
No. 200
Contenido de humedad de la fracci n de Suelo seco que pasa % de suelo seco que pasa la malla No. 200
la malla # 4 :
:
82.89
90
77.96
80
55.92%
69.08
15.46%
No. Tara
61.51
70
No. Tara
55.92
0.0728
60
57.24
Ubicacin
112.8
1128.0
103.4
724.0
Peso de Tara
42.6
Peso de Tara
426.0
9.4
404.0
Peso Seco
60.8
298.0
15.46%
55.92%
50
40
0.0364
30
20
0.0121
10
0 . 1
1.00
N o.200
N o.140
N o.100
N o.60
N o.40
N o.30
1 .0
N o.20
N o.16
N o.8
N o.10
3/8"
1/2"
3/4"
1"
OBSERVACIONES :
1 0
. 0
N o.4
TAMIZ
1 1/2"
2"
1 0 . 0
3"
4"
8"
1 0 0 . 0
6"
Cont. de humedad %
0
0 . 0
Las gra vas mayore s a la N 4, de acuerdo a l mue streo en campo, es de aprox ima dame nte
EJECUTO
REVISO
APROBO
Vo. Bo.
LA BORA TORISTA
10.53%
RESULTADO
CUMPLE
FECHA:
12/02/2011
FECHA :
13/02/2011
FECHA:
14/02/2011
FECHA:
15-feb
SI
CUMPLE
SI
FECHA :
15-feb
MA PA DE PELIGROS, PLA N DE USOS DEL SUELO ANTE DESASTRES Y MEDIDAS DE MITIGACIN DE EL TA MBO, HUANCAYO Y CHILCA
ANALISIS GRANULOMETRICO
Ttulo:
Fecha de revisin:
15-feb-11
CAL./mues tra
Proyecto:
ESTUDIO DE MAPA DE PELIGROS Y PLAN DE USO DE SUELOS ANTE DESASTRES Y MEDIDAS DE MITIGACION DE LA CIUDADES DE
HUANCAYO, EL TAMBO Y CHILCA
Contratante
M UN IC IP A L ID A D P R OV IN C IA L D E H U A N C A Y O
Sondaje
S19
Profundidad:
2.00
Mt.
Peso Reten.
A cumulado
%
Retenido
%
Pasa
T amao
Tamiz
Fecha muestreo:
07/02/2011
Muestreado por:
IN SITU
Muestra No.
2.00
Especific.
Ubicacin
HUANCAYO
8"
0.0
0.00%
100.00%
6"
0.0
0.00%
100.00%
4"
0.0
0.00%
100.00%
3"
0.0
0.00%
100.00%
2"
0.0
0.00%
100.00%
1 1/2"
0.0
0.00%
100.00%
1"
0.0
0.00%
100.00%
3/4"
32.0
5.33%
94.67%
BANDEJA
3/8"
4.0
0.67%
94.00%
1124.0
1022.0
422.0
No. 4
10.0
1.67%
92.33%
No. 10
22.0
3.67%
88.67%
744.0
No. 20
30.0
5.00%
83.67%
600.0
No. 40
66.0
11.00%
72.67%
No. 60
72.0
12.00%
60.67%
No. 100
52.0
8.67%
52.00%
0.1
0.1
0.2
0.4
0.3
0.9
1.2
0.6
2.0
4.8
2.4
CLASIF.(SUCS/
ASHTOO):
Tamao en mm
LP =
17
SM-SC
IP =
D 10 =
D 30 =
D 60 =
COLOR:
A-4 ( 3 )
0.014
0.043
0.085
MARRON
PROCEDENCIA:
88.67
90
21
Cc= 1.50
Cu= 6.00
92.33
94.00
94.67
9.5
12.7
37.5
19.0
100.00
100
100.00
25.4
101.6
0.00%
76.2
48.00%
48.00%
50.8
4.00%
288.0
203.2
24.0
Platillo
152.4
No. 200
LL =
83.67
Contenido de humedad de la fracci n de Suelo seco que pasa % de suelo seco que pasa la malla No. 200
la malla # 4 :
:
80
72.67
17.00%
48.00%
No. Tara
60.67
No. Tara
0.0850
60
52.0 0
50
112.4
1124.0
102.2
744.0
Peso de Tara
42.2
Peso de Tara
422.0
10.2
380.0
60.0
322.0
17.00%
48.00%
48.00
70
40
0.0425
30
20
Peso Seco
0.0142
10
0 . 1
1.00
N o.200
N o.140
N o.100
N o.60
N o.40
N o.30
1 .0
N o.20
N o.16
N o.8
N o.10
3/8"
1/2"
3/4"
1"
OBSERVACIONES :
1 0
. 0
N o.4
TAMIZ
1 1/2"
2"
1 0 . 0
3"
8"
1 0 0 . 0
4"
6"
Cont. de humedad %
0 . 0
Las gra vas mayore s a la N 4, de acuerdo a l mue streo en campo, es de aprox ima dame nte
EJECUTO
REVISO
APROBO
Vo. Bo.
LA BORA TORISTA
7.67%
RESULTADO
CUMPLE
FECHA:
12/02/2011
FECHA :
13/02/2011
FECHA:
14/02/2011
FECHA:
15-feb
SI
CUMPLE
SI
FECHA :
15-feb
MA PA DE PELIGROS, PLA N DE USOS DEL SUELO ANTE DESASTRES Y MEDIDAS DE MITIGACIN DE EL TA MBO, HUANCAYO Y CHILCA
ANALISIS GRANULOMETRICO
Ttulo:
Fecha de revisin:
15-feb-11
CAL./mues tra
Proyecto:
ESTUDIO DE MAPA DE PELIGROS Y PLAN DE USO DE SUELOS ANTE DESASTRES Y MEDIDAS DE MITIGACION DE LA CIUDADES DE
HUANCAYO, EL TAMBO Y CHILCA
Contratante
M UN IC IP A L ID A D P R OV IN C IA L D E H U A N C A Y O
Sondaje
S19
Profundidad:
T amao
Tamiz
3.00
Mt.
Peso Reten.
A cumulado
%
Retenido
%
Pasa
Fecha muestreo:
07/02/2011
Muestreado por:
IN SITU
Muestra No.
3.00
Especific.
HUANCAYO
8"
0.0
0.00%
100.00%
6"
0.0
0.00%
100.00%
4"
0.0
0.00%
100.00%
3"
0.0
0.00%
100.00%
2"
0.0
0.00%
100.00%
1 1/2"
0.0
0.00%
100.00%
1"
0.0
0.00%
100.00%
3/4"
56.0
8.41%
91.59%
BANDEJA
3/8"
136.0
20.42%
71.17%
1152.0
1100.0
434.0
No. 4
78.0
11.71%
59.46%
No. 10
60.0
9.01%
50.45%
958.0
No. 20
26.0
3.90%
46.55%
666.0
No. 40
60.0
9.01%
37.54%
No. 60
62.0
9.31%
28.23%
No. 100
26.0
3.90%
24.32%
90
21
LP =
17
0.1
0.1
Cc= 1.50
Cu= 6.00
0.2
0.4
0.3
0.9
1.2
0.6
2.0
4.8
2.4
LL =
CLASIF.(SUCS/
ASHTOO):
Tamao en mm
91.59
9.5
12.7
37.5
19.0
100.00
100.00
25.4
101.6
0.00%
76.2
21.92%
21.92%
50.8
2.40%
146.0
203.2
16.0
Platillo
152.4
No. 200
100
GM-GC
IP =
D 10 =
D 30 =
D 60 =
COLOR:
A-1-b ( 0 )
0.032
0.095
0.191
MARRON
PROCEDENCIA:
Contenido de humedad de la fracci n de Suelo seco que pasa % de suelo seco que pasa la malla No. 200
la malla # 4 :
:
80
7.81%
71.17
70
No. Tara
59.46
60
21.92%
1
No. Tara
0.1910
50.45
50
46.55
40
37.54
115.2
1152.0
110.0
958.0
Peso de Tara
43.4
Peso de Tara
434.0
5.2
194.0
Peso Seco
66.6
524.0
7.81%
21.92%
0.0 955
24.32
28.23
30
20
21.92
Ubicacin
0.0318
10
0 . 1
1.00
N o.200
N o.140
N o.100
N o.60
N o.40
N o.30
1 .0
N o.20
N o.16
N o.8
N o.10
3/8"
1/2"
3/4"
1"
OBSERVACIONES :
1 0
. 0
N o.4
TAMIZ
1 1/2"
2"
1 0 . 0
3"
4"
8"
1 0 0 . 0
6"
Cont. de humedad %
0
0 . 0
Las gra vas mayore s a la N 4, de acuerdo a l mue streo en campo, es de aprox ima dame nte
EJECUTO
REVISO
APROBO
Vo. Bo.
LA BORA TORISTA
40.54%
RESULTADO
CUMPLE
FECHA:
12/02/2011
FECHA :
13/02/2011
FECHA:
14/02/2011
FECHA:
15-feb
SI
CUMPLE
SI
FECHA :
15-feb
MA PA DE PELIGROS, PLA N DE USOS DEL SUELO ANTE DESASTRES Y MEDIDAS DE MITIGACIN DE EL TA MBO, HUANCAYO Y CHILCA
ANALISIS GRANULOMETRICO
Ttulo:
Fecha de revisin:
15-feb-11
CAL./mues tra
Proyecto:
ESTUDIO DE MAPA DE PELIGROS Y PLAN DE USO DE SUELOS ANTE DESASTRES Y MEDIDAS DE MITIGACION DE LA CIUDADES DE
HUANCAYO, EL TAMBO Y CHILCA
Contratante
M UN IC IP A L ID A D P R OV IN C IA L D E H U A N C A Y O
Sondaje
S20
Profundidad:
1.00
T amao
Tamiz
Mt.
Peso Reten.
A cumulado
Fecha muestreo:
07/02/2011
Muestreado por:
IN SITU
Muestra No.
1.00
Ubicacin
PARQUE PUZO
%
Retenido
%
Pasa
8"
0.0
0.00%
100.00%
6"
0.0
0.00%
100.00%
4"
0.0
0.00%
100.00%
3"
0.0
0.00%
100.00%
2"
0.0
0.00%
100.00%
1 1/2"
0.0
0.00%
100.00%
1"
0.0
0.00%
100.00%
3/4"
56.0
9.03%
90.97%
BANDEJA
3/8"
92.0
14.84%
76.13%
1120.0
1050.0
Especific.
430.0
No. 4
80.0
12.90%
63.23%
No. 10
82.0
13.23%
50.00%
882.0
No. 20
44.0
7.10%
42.90%
620.0
No. 40
40.0
6.45%
36.45%
No. 60
18.0
2.90%
33.55%
No. 100
18.0
2.90%
30.65%
0.1
0.1
0.2
0.4
0.3
0.9
1.2
0.6
2.0
4.8
2.4
9.5
12.7
19.0
100.00
90
21
LP =
17
Cc= 1.50
Cu= 6.00
CLASIF.(SUCS/
ASHTOO):
Tamao en mm
GM-GC
IP =
D 10 =
D 30 =
D 60 =
A-2-4 ( 0 )
COLOR:
0.024
0.073
0.146
MARRON
PROCEDENCIA:
90.97
100
100.00
25.4
76.2
37.5
0.00%
101.6
28.39%
28.39%
50.8
2.26%
176.0
203.2
14.0
Platillo
152.4
No. 200
LL =
Contenido de humedad de la fracci n de Suelo seco que pasa % de suelo seco que pasa la malla No. 200
la malla # 4 :
:
76.13
80
11.29%
28.39%
63.23
No. Tara
60
No. Tara
0.1459
112
1120.0
50.00
50
42.90
105.0
882.0
Peso de Tara
43.0
Peso de Tara
430.0
7.0
238.0
Peso Seco
62.0
452.0
11.29%
28.39%
28.39
0.0730
30
30.65
36.45
40
33.55
70
20
0.0243
10
0 . 1
1.00
No.200
No.140
No.100
N o.6 0
N o.4 0
N o.3 0
1 .0
N o.2 0
N o.1 6
No.8
N o.1 0
3/8 "
3/4 "
1/2"
1"
OBSERVACIONES :
1 0
. 0
N o.4
TAMIZ
1 1/2"
2"
1 0 . 0
3"
8"
4"
1 0 0 . 0
6"
Cont. de humedad %
0
0 . 0
Las gra vas mayore s a la N 4, de acuerdo a l mue streo en campo, es de aprox ima dame nte
EJECUTO
REVISO
APROBO
Vo. Bo.
LA BORA TORISTA
36.77%
RESULTADO
CUMPLE
FECHA:
12/02/2011
FECHA :
13/02/2011
FECHA:
14/02/2011
FECHA:
15-feb
SI
CUMPLE
SI
FECHA :
15-feb
MA PA DE PELIGROS, PLA N DE USOS DEL SUELO ANTE DESASTRES Y MEDIDAS DE MITIGACIN DE EL TA MBO, HUANCAYO Y CHILCA
ANALISIS GRANULOMETRICO
Ttulo:
Fecha de revisin:
15-feb-11
CAL./mues tra
Proyecto:
ESTUDIO DE MAPA DE PELIGROS Y PLAN DE USO DE SUELOS ANTE DESASTRES Y MEDIDAS DE MITIGACION DE LA CIUDADES DE
HUANCAYO, EL TAMBO Y CHILCA
Contratante
M UN IC IP A L ID A D P R OV IN C IA L D E H U A N C A Y O
Sondaje
S20
Profundidad:
T amao
Tamiz
2.00
Mt.
Peso Reten.
A cumulado
%
Retenido
%
Pasa
Fecha muestreo:
07/02/2011
Muestreado por:
IN SITU
Muestra No.
2.00
Especific.
Ubicacin
PARQUE PUZO
8"
0.0
0.00%
100.00%
6"
0.0
0.00%
100.00%
4"
0.0
0.00%
100.00%
3"
0.0
0.00%
100.00%
2"
0.0
0.00%
100.00%
1 1/2"
0.0
0.00%
100.00%
1"
0.0
0.00%
100.00%
3/4"
24.0
4.17%
95.83%
BANDEJA
3/8"
0.0
0.00%
95.83%
1116.0
1014.0
438.0
No. 4
16.0
2.78%
93.06%
No. 10
42.0
7.29%
85.76%
598.0
No. 20
22.0
3.82%
81.94%
576.0
No. 40
18.0
3.13%
78.82%
No. 60
8.0
1.39%
77.43%
No. 100
10.0
1.74%
75.69%
0.1
0.1
0.2
0.4
0.3
0.9
1.2
0.6
4.8
2.4
24
LP =
17
Cc= 1.50
Cu= 6.00
CLASIF.(SUCS/
ASHTOO):
Tamao en mm
93.06
2.0
9.5
12.7
95.83
19.0
100.00
100.00
25.4
100
95.83
76.2
37.5
0.00%
101.6
73.61%
73.61%
50.8
2.08%
424.0
203.2
12.0
Platillo
152.4
No. 200
LL =
ML-CL
IP =
D 10 =
D 30 =
D 60 =
A-4 ( 8 )
COLOR:
0.009
0.028
0.055
MARRON
PROCEDENCIA:
Contenido de humedad de la fracci n de Suelo seco que pasa % de suelo seco que pasa la malla No. 200
la malla # 4 :
:
17.71%
73.61
75.69
77.4 3
80
78.82
81.94
85.76
90
73.61%
70
No. Tara
60
No. Tara
0.0550
111.6
1116.0
101.4
598.0
Peso de Tara
43.8
Peso de Tara
438.0
10.2
518.0
Peso Seco
57.6
160.0
17.71%
73.61%
50
40
0.0275
30
20
10
0 . 1
1.00
No.200
No.140
No.100
N o.6 0
N o.4 0
N o.3 0
1 .0
N o.2 0
N o.1 6
No.8
N o.1 0
3/8 "
3/4 "
1/2"
1"
OBSERVACIONES :
1 0
. 0
N o.4
TAMIZ
1 1/2"
1 0 . 0
2"
8"
4"
6"
1 0 0 . 0
3"
Cont. de humedad %
0
0 . 0
Las gra vas mayore s a la N 4, de acuerdo a l mue streo en campo, es de aprox ima dame nte
EJECUTO
REVISO
APROBO
Vo. Bo.
LA BORA TORISTA
6.94%
RESULTADO
CUMPLE
FECHA:
12/02/2011
FECHA :
13/02/2011
FECHA:
14/02/2011
FECHA:
15-feb
SI
CUMPLE
SI
FECHA :
15-feb
MA PA DE PELIGROS, PLA N DE USOS DEL SUELO ANTE DESASTRES Y MEDIDAS DE MITIGACIN DE EL TA MBO, HUANCAYO Y CHILCA
ANALISIS GRANULOMETRICO
Ttulo:
Fecha de revisin:
15-feb-11
CAL./mues tra
Proyecto:
ESTUDIO DE MAPA DE PELIGROS Y PLAN DE USO DE SUELOS ANTE DESASTRES Y MEDIDAS DE MITIGACION DE LA CIUDADES DE
HUANCAYO, EL TAMBO Y CHILCA
Contratante
M U N IC IP A L ID A D P R O VIN C IA L D E H UA N C A Y O
Sondaje
S20
Profundidad:
3.00
T amao
Tamiz
Mt.
Peso Reten.
Ac um ulado
Fecha muestreo:
07/02/2011
IN SITU
3.00
Ubicacin
PARQUE PUZO
%
Retenido
%
Pas a
8"
0.0
0.00%
100.00%
6"
0.0
0.00%
100.00%
4"
0.0
0.00%
100.00%
3"
0.0
0.00%
100.00%
2"
0.0
0.00%
100.00%
1 1/2"
0.0
0.00%
100.00%
1"
0.0
0.00%
100.00%
3/4"
0.0
0.00%
100.00%
BANDEJA
3/8"
0.0
0.00%
100.00%
Especif ic .
426.0
1100.0
No. 4
14.0
2.49%
97.51%
988.0
No. 10
30.0
5.34%
92.17%
544.0
No. 20
22.0
3.91%
88.26%
562.0
No. 40
20.0
3.56%
84.70%
No. 60
8.0
1.42%
83.27%
No. 100
8.0
1.42%
81.85%
0.1
0.1
0.2
0.4
0.3
0.9
1.2
0.6
2.0
4.8
2.4
CLASIF.(SUCS/
ASHTOO):
Tamao en mm
92.17
LP =
17
CL
IP =
D 10 =
D 30 =
D 60 =
COLOR:
A-4 ( 8 )
0.008
0.025
0.051
MARRON
PROCEDENCIA:
80
Contenido de humedad de la f raccin de Suelo seco que pasa % de suelo seco que pasa la malla No. 200
la malla # 4 :
:
79.72
81.85
83.27
84.70
88.26
90
26
Cc= 1.50
Cu= 6.00
97.51
9.5
100.00
100.00
12.7
37.5
19.0
100.00
100
100.00
25.4
101.6
0.00%
76.2
79.72%
79.72%
50.8
2.14%
448.0
203.2
12.0
Platillo
152.4
No. 200
LL =
19.93%
79.72%
70
No. Tara
No. Tara
0.0508
60
110
1100.0
98.8
544.0
Peso de Tara
42.6
Peso de Tara
426.0
11.2
556.0
Peso Seco
56.2
118.0
19.93%
79.72%
50
40
0.0254
30
20
10
OBSERVACIONES :
0 . 1
1.00
N o.200
N o.140
N o.100
N o.60
N o.40
N o.30
1 . 0
N o.20
N o.16
N o.8
N o.10
3/8"
1/2"
3/4"
1"
1 0 . 0
N o.4
TAMIZ
1 1/2"
2"
1 0 0 .0
3"
4"
8"
1 0 0 . 0
6"
Cont. de humedad %
0
0 . 0
EJECUTO
REVISO
APROBO
Vo. Bo.
LA BORA TORISTA
ROAD TECH SA C
2.49%
RESULTADO
CUMPLE
FECHA:
12/02/2011
FECHA:
13/02/2011
FECHA:
14/02/2011
FECHA :
15-feb
SI
CUMPLE
SI
FECHA :
15-feb
MA PA DE PELIGROS, PLA N DE USOS DEL SUELO ANTE DESASTRES Y MEDIDAS DE MITIGACIN DE EL TA MBO, HUANCAYO Y CHILCA
ANALISIS GRANULOMETRICO
Ttulo:
Fecha de revisin:
15-feb-11
CAL./mues tra
Proyecto:
ESTUDIO DE MAPA DE PELIGROS Y PLAN DE USO DE SUELOS ANTE DESASTRES Y MEDIDAS DE MITIGACION DE LA CIUDADES DE
HUANCAYO, EL TAMBO Y CHILCA
Contratante
M UN IC IP A L ID A D P R OV IN C IA L D E H U A N C A Y O
Sondaje
S21
Profundidad:
T amao
Tamiz
1.30
Mt.
Peso Reten.
A cumulado
%
Retenido
%
Pasa
Fecha muestreo:
07/02/2011
Muestreado por:
IN SITU
Muestra No.
1.00
Especific.
HUANCAYO
8"
0.0
0.00%
100.00%
6"
0.0
0.00%
100.00%
4"
0.0
0.00%
100.00%
3"
0.0
0.00%
100.00%
2"
0.0
0.00%
100.00%
1 1/2"
0.0
0.00%
100.00%
1"
0.0
0.00%
100.00%
3/4"
22.0
3.11%
96.89%
BANDEJA
3/8"
40.0
5.65%
91.24%
1264.0
1138.0
430.0
No. 4
54.0
7.63%
83.62%
No. 10
90.0
12.71%
70.90%
784.0
No. 20
44.0
6.21%
64.69%
708.0
No. 40
36.0
5.08%
59.60%
No. 60
16.0
2.26%
57.34%
No. 100
14.0
1.98%
55.37%
0.1
0.1
CLASIF.(SUCS/
ASHTOO):
Tamao en mm
LP =
17
ML
IP =
D 10 =
D 30 =
D 60 =
COLOR:
A-4 ( 4 )
0.013
0.038
0.075
MARRON
PROCEDENCIA:
91.24
Contenido de humedad de la fracci n de Suelo seco que pasa % de suelo seco que pasa la malla No. 200
la malla # 4 :
:
83.62
90
19
Cc= 1.50
Cu= 6.00
0.2
0.4
0.3
0.9
1.2
0.6
2.0
4.8
2.4
9.5
12.7
LL =
96.89
37.5
19.0
100.00
100.00
25.4
101.6
0.00%
76.2
53.95%
53.95%
50.8
1.41%
382.0
203.2
10.0
Platillo
152.4
No. 200
100
80
17.80%
70.90
64.69
70
59.60
No. Tara
53.95%
1
No. Tara
53.95
0.0755
55.37
60
57.34
Ubicacin
126.4
1264.0
113.8
784.0
Peso de Tara
43.0
Peso de Tara
430.0
12.6
480.0
Peso Seco
70.8
354.0
17.80%
53.95%
50
40
0.0377
30
20
0.0126
10
0 . 1
1.00
N o.200
N o.140
N o.100
N o.60
N o.40
N o.30
1 .0
N o.20
N o.16
N o.8
N o.10
3/8"
1/2"
3/4"
1"
OBSERVACIONES :
1 0
. 0
N o.4
TAMIZ
1 1/2"
2"
1 0 . 0
3"
4"
8"
1 0 0 . 0
6"
Cont. de humedad %
0
0 . 0
Las gra vas mayore s a la N 4, de acuerdo a l mue streo en campo, es de aprox ima dame nte
EJECUTO
REVISO
APROBO
Vo. Bo.
LA BORA TORISTA
16.38%
RESULTADO
CUMPLE
FECHA:
12/02/2011
FECHA :
13/02/2011
FECHA:
14/02/2011
FECHA:
15-feb
SI
CUMPLE
SI
FECHA :
15-feb
MA PA DE PELIGROS, PLA N DE USOS DEL SUELO ANTE DESASTRES Y MEDIDAS DE MITIGACIN DE EL TA MBO, HUANCAYO Y CHILCA
ANALISIS GRANULOMETRICO
Ttulo:
Fecha de revisin:
15-feb-11
CAL./mues tra
Proyecto:
ESTUDIO DE MAPA DE PELIGROS Y PLAN DE USO DE SUELOS ANTE DESASTRES Y MEDIDAS DE MITIGACION DE LA CIUDADES DE
HUANCAYO, EL TAMBO Y CHILCA
Contratante
M UN IC IP A L ID A D P R OV IN C IA L D E H U A N C A Y O
Sondaje
S21
Profundidad:
T amao
Tamiz
3.00
Mt.
Peso Reten.
A cumulado
%
Retenido
%
Pasa
Fecha muestreo:
07/02/2011
Muestreado por:
IN SITU
Muestra No.
2.00
Especific.
Ubicacin
HUANCAYO
8"
0.0
0.00%
100.00%
6"
0.0
0.00%
100.00%
4"
0.0
0.00%
100.00%
3"
0.0
0.00%
100.00%
2"
0.0
0.00%
100.00%
1 1/2"
0.0
0.00%
100.00%
1"
0.0
0.00%
100.00%
3/4"
0.0
0.00%
100.00%
BANDEJA
3/8"
0.0
0.00%
100.00%
422.0
1138.0
14.0
2.44%
93.03%
574.0
No. 40
14.0
2.44%
90.59%
No. 60
6.0
1.05%
89.55%
No. 100
2.0
0.35%
89.20%
2.0
0.35%
88.85%
510.0
88.85%
0.00%
23
LP =
17
0.1
CLASIF.(SUCS/
ASHTOO):
Tamao en mm
ML-CL
IP =
D 10 =
D 30 =
D 60 =
COLOR:
A-4 ( 8 )
0.008
0.023
0.045
MARRON
PROCEDENCIA:
88.85
89.20
0.1
Cc= 1.50
Cu= 6.00
0.2
0.3
90.59
90
LL =
89.5 5
1.2
0.6
93.03
95.47
9.5
2.4
98.61
100
100.00
37.5
101.6
76.2
203.2
152.4
Platillo
50.8
No. 200
0.4
994.0
No. 20
0.9
996.0
2.0
95.47%
4.8
98.61%
3.14%
100.00
12.7
1.39%
19.0
100.00
8.0
18.0
100.00
25.4
No. 4
No. 10
Contenido de humedad de la fracci n de Suelo seco que pasa % de suelo seco que pasa la malla No. 200
la malla # 4 :
:
80
24.74%
88.85%
70
No. Tara
No. Tara
0.0455
60
113.8
1138.0
99.6
994.0
Peso de Tara
42.2
Peso de Tara
422.0
14.2
144.0
Peso Seco
57.4
572.0
24.74%
88.85%
50
40
0.0227
30
20
10
0 . 1
1.00
N o.200
N o.140
N o.100
N o.60
N o.40
N o.30
1 .0
N o.20
N o.16
N o.8
N o.10
3/8"
1/2"
3/4"
1"
OBSERVACIONES :
1 0
. 0
N o.4
TAMIZ
1 1/2"
2"
1 0 . 0
3"
4"
8"
1 0 0 . 0
6"
Cont. de humedad %
0
0 . 0
Las gra vas mayore s a la N 4, de acuerdo a l mue streo en campo, es de aprox ima dame nte
EJECUTO
REVISO
APROBO
Vo. Bo.
LA BORA TORISTA
1.39%
RESULTADO
CUMPLE
FECHA:
12/02/2011
FECHA :
13/02/2011
FECHA:
14/02/2011
FECHA:
15-feb
SI
CUMPLE
SI
FECHA :
15-feb
MA PA DE PELIGROS, PLA N DE USOS DEL SUELO ANTE DESASTRES Y MEDIDAS DE MITIGACIN DE EL TA MBO, HUANCAYO Y CHILCA
MA PA DE PELIGROS, PLA N DE USOS DEL SUELO ANTE DESASTRES Y MEDIDAS DE MITIGACIN DE EL TA MBO, HUANCAYO Y CHILCA
DEPARTAMENTO DE GEOTCNIA
REGISTRO DE SONDAJE
SONDAJE : SPT- 01
PROYECTO : MAPA DE PELIGROS, PLAN DE USOS DEL SUELO ANTE
DESASTRES Y MEDIDAS DE MITIGACIN DE HUANCAYO
P R OF .
(m)
S
U
C
S
CORRELACIONES
F
N
SPT
c
2
( Kg / cm )
suel o
suelo
fr i ccio nant eco hesi vo
ENSAYOS DE
PENETRACION
ESTANDAR
N=
N d e g o l p es
0
10 20 30 40 50
0. 0
GM
17
33.4
0. 5
25
1.00
37.4
1. 0
GP
29
39.1
1. 5
33
2.00
40.7
2. 0
GP
35
41.5
2. 5
36
3.00
41.8
3. 0
3. 5
4.00
PANEL FOTOGRAFICO
4. 0
4. 5
5. 0
5. 5
6. 0
6. 5
7. 0
EN ESTE SONDAJE SE PUEDE OBSERVAR LA PRESENCIA DE MATERIAL HORMIGON, EN ESTA ZONA MUY CERCA
AL TERMINAL TERRESTRE Qadm = 3.85 kg/cm2
MA PA DE PELIGROS, PLA N DE USOS DEL SUELO ANTE DESASTRES Y MEDIDAS DE MITIGACIN DE EL TA MBO, HUANCAYO Y CHILCA
DEPARTAMENTO DE GEOTCNIA
REGISTRO DE SONDAJE
SONDAJE : SPT- 02
PROYECTO : MAPA DE PELIGROS, PLAN DE USOS DEL SUELO ANTE
DESASTRES Y MEDIDAS DE MITIGACIN DE HUANCAYO
P R OF .
(m)
CORRELACIONES
F
N
SPT
c
2
(Kg / cm )
suelo
suel o
f ri ccio nant eco hesivo
ENSAYOS DE
PENETRACION
ESTANDAR
N=
N d e g o l p es
0
10 20 30 40 50
0.0
GP
26
37.8
0.5
25
1.00
La segunda capa de suelo de 1.00 m explorada, es un suelo del tipo GPGM, con humedad
GP-GM
37.4
1.0
29
39.1
1.5
33
2.00
La tercera capa de suelo de 1.00 m explorada, es un suelo del tipo GPGM, com pres encia dehumedad.
40.7
2.0
GP-GM
35
41.5
2.5
36
3.00
41.8
3.0
3.5
4.00
PANEL FOTOGRAFICO
4.0
4.5
5.0
5.5
6.0
6.5
7.0
EN ESTE SONDAJE SE PUEDE OBSERVA LA EJECUCION DEL ENSAYO, ASI MSIMO SE NOTA EL
PERFIL ESTRATIGRAFICO DEL TERRENO Qadm = 3.85 kg/cm2
MA PA DE PELIGROS, PLA N DE USOS DEL SUELO ANTE DESASTRES Y MEDIDAS DE MITIGACIN DE EL TA MBO, HUANCAYO Y CHILCA
DEPARTAMENTO DE GEOTCNIA
REGISTRO DE SONDAJE
SONDAJE : SPT- 03
PROYECTO : MAPA DE PELIGROS, PLAN DE USOS DEL SUELO ANTE
DESASTRES Y MEDIDAS DE MITIGACIN DE HUANCAYO
P R OF .
(m)
S
U
C
S
CORRELACIONES
F
( Kg / cm )
SPT
suel o
suelo
fr i ccio nant eco hesi vo
ENSAYOS DE
PENETRACION
ESTANDAR
N=
N d e g o l p es
0
10 20 30 40 50
0. 0
GP
26
37.8
0. 5
25
1.00
37.4
1. 0
GM
22
36.0
1. 5
30
2.00
39.5
2. 0
GM
35
41.5
2. 5
36
3.00
41.8
3. 0
3. 5
4.00
PANEL FOTOGRAFICO
4. 0
4. 5
5. 0
5. 5
6. 0
6. 5
7. 0
EN ESTE SONDAJE SE PUEDE OBSERVA LA EJECUCION DEL ENSAYO, ASI MSIMO SE NOTA EL
PERFIL ESTRATIGRAFICO DEL TERRENO Qadm = 2.60 kg/cm2
MA PA DE PELIGROS, PLA N DE USOS DEL SUELO ANTE DESASTRES Y MEDIDAS DE MITIGACIN DE EL TA MBO, HUANCAYO Y CHILCA
DEPARTAMENTO DE GEOTCNIA
REGISTRO DE SONDAJE
SONDAJE : SPT- 04
PROYECTO : MAPA DE PELIGROS, PLAN DE USOS DEL SUELO ANTE
DESASTRES Y MEDIDAS DE MITIGACIN DE HUANCAYO
P R OF .
(m)
S
U
C
S
CORRELACIONES
F
( Kg / cm )
SPT
suel o
suelo
fr i ccio nant eco hesi vo
ENSAYOS DE
PENETRACION
ESTANDAR
N=
N d e g o l p es
0
10 20 30 40 50
0. 0
GM
23
36.4
0. 5
24
1.00
36.9
1. 0
GM
23
36.4
1. 5
30
2.00
39.5
2. 0
GM
35
41.5
2. 5
36
3.00
41.8
3. 0
3. 5
4.00
PANEL FOTOGRAFICO
4. 0
4. 5
5. 0
5. 5
6. 0
6. 5
7. 0
EN ESTE SONDAJE SE PUEDE OBSERVA LA EJECUCION DEL ENSAYO, ASI MSIMO SE NOTA EL
PERFIL ESTRATIGRAFICO DEL TERRENO Qadm = 4.65 kg/cm2
MA PA DE PELIGROS, PLA N DE USOS DEL SUELO ANTE DESASTRES Y MEDIDAS DE MITIGACIN DE EL TA MBO, HUANCAYO Y CHILCA
DEPARTAMENTO DE GEOTCNIA
REGISTRO DE SONDAJE
SONDAJE : SPT- 05
PROYECTO : MAPA DE PELIGROS, PLAN DE USOS DEL SUELO ANTE
DESASTRES Y MEDIDAS DE MITIGACIN DE HUANCAYO
P R OF .
(m)
S
U
C
S
CORRELACIONES
N
SPT
c
2
( Kg / cm )
suel o
suelo
fr i ccio nant eco hesi vo
ENSAYOS DE
PENETRACION
ESTANDAR
N=
N d e g o l p es
0
10 20 30 40 50
0. 0
GP
28
38.7
0. 5
30
1.00
39.5
1. 0
GP
34
41.1
1. 5
36
2.00
41.8
2. 0
GP
36
41.8
2. 5
36
3.00
41.8
3. 0
3. 5
4.00
PANEL FOTOGRAFICO
4. 0
4. 5
5. 0
5. 5
6. 0
6. 5
7. 0
EN ESTE SONDAJE SE PUEDE OBSERVA LA EJECUCION DEL ENSAYO, ASI MSIMO SE NOTA EL
PERFIL ESTRATIGRAFICO DEL TERRENO Qadm = 5.83 kg/cm2
MA PA DE PELIGROS, PLA N DE USOS DEL SUELO ANTE DESASTRES Y MEDIDAS DE MITIGACIN DE EL TA MBO, HUANCAYO Y CHILCA
DEPARTAMENTO DE GEOTCNIA
REGISTRO DE SONDAJE
SONDAJE : SPT- 06
PROYECTO : MAPA DE PELIGROS, PLAN DE USOS DEL SUELO ANTE
DESASTRES Y MEDIDAS DE MITIGACIN DE HUANCAYO
P R OF .
(m)
CORRELACIONES
N
SPT
c
2
( Kg / cm )
suel o
suelo
fr i ccio nant eco hesi vo
ENSAYOS DE
PENETRACION
ESTANDAR
N=
N d e g o l p es
0
10 20 30 40 50
0. 0
GP
28
38.7
0. 5
32
1.00
40.3
1. 0
GP
35
41.5
1. 5
38
2.00
La tercera capa de suelo de 1.00 m explorada, es un suelo del tipo GPGM, com presencia dehumedad.
42.6
2. 0
GP-GM
38
42.6
2. 5
38
3.00
42.6
3. 0
3. 5
4.00
PANEL FOTOGRAFICO
4. 0
4. 5
5. 0
5. 5
6. 0
6. 5
7. 0
EN ESTE SONDAJE SE PUEDE OBSERVA LA EJECUCION DEL ENSAYO, ASI MSIMO SE NOTA EL
PERFIL ESTRATIGRAFICO DEL TERRENO Qadm = 6.42 kg/cm2
MA PA DE PELIGROS, PLA N DE USOS DEL SUELO ANTE DESASTRES Y MEDIDAS DE MITIGACIN DE EL TA MBO, HUANCAYO Y CHILCA
DEPARTAMENTO DE GEOTCNIA
REGISTRO DE SONDAJE
SONDAJE : SPT- 07
PROYECTO : MAPA DE PELIGROS, PLAN DE USOS DEL SUELO ANTE
DESASTRES Y MEDIDAS DE MITIGACIN DE HUANCAYO
P R OF .
(m)
S
U
C
S
CORRELACIONES
N
SPT
c
2
( Kg / cm )
suel o
suelo
fr i ccio nant eco hesi vo
ENSAYOS DE
PENETRACION
ESTANDAR
N=
N d e g o l p es
0
10 20 30 40 50
0. 0
GM
24
36.9
0. 5
24
1.00
36.9
1. 0
GP
26
37.8
1. 5
30
2.00
39.5
2. 0
GP
30
39.5
2. 5
30
3.00
39.5
3. 0
3. 5
4.00
PANEL FOTOGRAFICO
4. 0
4. 5
5. 0
5. 5
6. 0
6. 5
7. 0
EN ESTE SONDAJE SE PUEDE OBSERVA LA EJECUCION DEL ENSAYO, ASI MSIMO SE NOTA EL
PERFIL ESTRATIGRAFICO DEL TERRENO Qadm = 2.60 kg/cm2
MA PA DE PELIGROS, PLA N DE USOS DEL SUELO ANTE DESASTRES Y MEDIDAS DE MITIGACIN DE EL TA MBO, HUANCAYO Y CHILCA
DEPARTAMENTO DE GEOTCNIA
REGISTRO DE SONDAJE
SONDAJE : SPT- 08
PROYECTO : MAPA DE PELIGROS, PLAN DE USOS DEL SUELO ANTE
DESASTRES Y MEDIDAS DE MITIGACIN DE HUANCAYO
P RO F.
( m)
S
U
C
S
CORRELACIONES
N
S PT
suel o
( Kg / cm )
suelo
ENSAYOS DE
PENETRACION
ESTANDAR
N=
N d e g o l p es
0
10 20 30 40 50
0. 0
GP
22
36.0
0. 5
23
1.00
36.4
1. 0
GM
23
36.4
1. 5
27
2.00
38.2
2. 0
GM
30
39.5
2. 5
30
3.00
39.5
3. 0
3. 5
4.00
PANEL FOTOGRAFICO
4. 0
4. 5
5. 0
5. 5
6. 0
6. 5
7. 0
EN ESTE SONDAJE SE PUEDE OBSERVA LA EJECUCION DEL ENSAYO, ASI MSIMO SE NOTA EL
PERFIL ESTRATIGRAFICO DEL TERRENO Qadm = 1.78 kg/cm2
MA PA DE PELIGROS, PLA N DE USOS DEL SUELO ANTE DESASTRES Y MEDIDAS DE MITIGACIN DE EL TA MBO, HUANCAYO Y CHILCA
DEPARTAMENTO DE GEOTCNIA
REGISTRO DE SONDAJE
SONDAJE : SPT- 09
PROYECTO : MAPA DE PELIGROS, PLAN DE USOS DEL SUELO ANTE
DESASTRES Y MEDIDAS DE MITIGACIN DE HUANCAYO
P R OF .
(m)
S
U
C
S
CORRELACIONES
N
SPT
c
2
( Kg / cm )
suel o
suelo
fr i ccio nant eco hesi vo
ENSAYOS DE
PENETRACION
ESTANDAR
N=
N d e g o l p es
0
10 20 30 40 50
0. 0
SM
16
32.9
0. 5
15
1.00
32.3
1. 0
ML
16
32.9
1. 5
18
2.00
34.0
2. 0
ML
20
35.0
2. 5
20
3.00
35.0
3. 0
3. 5
4.00
PANEL FOTOGRAFICO
4. 0
4. 5
5. 0
5. 5
6. 0
6. 5
7. 0
EN ESTE SONDAJE SE PUEDE OBSERVA LA EJECUCION DEL ENSAYO, ASI MSIMO SE NOTA EL
PERFIL ESTRATIGRAFICO DEL TERRENO Qadm = 1.08 kg/cm2
MA PA DE PELIGROS, PLA N DE USOS DEL SUELO ANTE DESASTRES Y MEDIDAS DE MITIGACIN DE EL TA MBO, HUANCAYO Y CHILCA
DEPARTAMENTO DE GEOTCNIA
REGISTRO DE SONDAJE
SONDAJE : SPT- 10
PROYECTO : MAPA DE PELIGROS, PLAN DE USOS DEL SUELO ANTE
DESASTRES Y MEDIDAS DE MITIGACIN DE HUANCAYO
P R OF .
(m)
S
U
C
S
CORRELACIONES
N
SPT
c
2
( Kg / cm )
suel o
suelo
fr i ccio nant eco hesi vo
ENSAYOS DE
PENETRACION
ESTANDAR
N=
N d e g o l p es
0
10 20 30 40 50
0. 0
SM
16
32.9
0. 5
15
1.00
32.3
1. 0
SM
16
32.9
1. 5
24
2.00
36.9
2. 0
SM
30
39.5
2. 5
30
3.00
39.5
3. 0
3. 5
4.00
PANEL FOTOGRAFICO
4. 0
4. 5
5. 0
5. 5
6. 0
6. 5
7. 0
EN ESTE SONDAJE SE PUEDE OBSERVA LA EJECUCION DEL ENSAYO, ASI MSIMO SE NOTA EL
PERFIL ESTRATIGRAFICO DEL TERRENO Qadm = 2.24 kg/cm2
MA PA DE PELIGROS, PLA N DE USOS DEL SUELO ANTE DESASTRES Y MEDIDAS DE MITIGACIN DE EL TA MBO, HUANCAYO Y CHILCA
DEPARTAMENTO DE GEOTCNIA
REGISTRO DE SONDAJE
SONDAJE : SPT- 11
PROYECTO : MAPA DE PELIGROS, PLAN DE USOS DEL SUELO ANTE
DESASTRES Y MEDIDAS DE MITIGACIN DE HUANCAYO
P R OF .
(m)
S
U
C
S
CORRELACIONES
F
N
SPT
c
2
( Kg / cm )
suel o
suelo
fr i ccio nant eco hesi vo
ENSAYOS DE
PENETRACION
ESTANDAR
N=
N d e g o l p es
0
10 20 30 40 50
0. 0
SM
14
31.7
0. 5
15
1.00
32.3
1. 0
GM
15
32.3
1. 5
25
2.00
37.4
2. 0
GM
28
38.7
2. 5
30
3.00
39.5
3. 0
3. 5
4.00
PANEL FOTOGRAFICO
4. 0
4. 5
5. 0
5. 5
6. 0
6. 5
7. 0
EN ESTE SONDAJE SE PUEDE OBSERVA LA EJECUCION DEL ENSAYO, ASI MSIMO SE NOTA EL
PERFIL ESTRATIGRAFICO DEL TERRENO Qadm = 2.52 kg/cm2
MA PA DE PELIGROS, PLA N DE USOS DEL SUELO ANTE DESASTRES Y MEDIDAS DE MITIGACIN DE EL TA MBO, HUANCAYO Y CHILCA
DEPARTAMENTO DE GEOTCNIA
REGISTRO DE SONDAJE
SONDAJE : SPT- 12
PROYECTO : MAPA DE PELIGROS, PLAN DE USOS DEL SUELO ANTE
DESASTRES Y MEDIDAS DE MITIGACIN DE HUANCAYO
P R OF .
(m)
CORRELACIONES
F
N
SPT
c
2
( Kg / cm )
suel o
suelo
fr i ccio nant eco hesi vo
ENSAYOS DE
PENETRACION
ESTANDAR
N=
N d e g o l p es
0
10 20 30 40 50
0. 0
ML-CL
21.3
0. 5
1.00
La segunda c apa de s uelo de 1.00 m explorada, es un s uelo del tipo MLCL, con humedad
ML-CL
25.0
1. 0
28.4
1. 5
2.00
La tercera capa de suelo de 1.00 m explorada, es un suelo del tipo MLCL, com presenc ia dehumedad.
27.6
2. 0
ML-CL
27.6
2. 5
3.00
27.6
3. 0
3. 5
4.00
PANEL FOTOGRAFICO
4. 0
4. 5
5. 0
5. 5
6. 0
6. 5
7. 0
EN ESTE SONDAJE SE PUEDE OBSERVA LA EJECUCION DEL ENSAYO, ASI MSIMO SE NOTA EL
PERFIL ESTRATIGRAFICO DEL TERRENO Qadm = 1.09 kg/cm2
MA PA DE PELIGROS, PLA N DE USOS DEL SUELO ANTE DESASTRES Y MEDIDAS DE MITIGACIN DE EL TA MBO, HUANCAYO Y CHILCA
DEPARTAMENTO DE GEOTCNIA
REGISTRO DE SONDAJE
SONDAJE : SPT- 13
PROYECTO : MAPA DE PELIGROS, PLAN DE USOS DEL SUELO ANTE
DESASTRES Y MEDIDAS DE MITIGACIN DE HUANCAYO
P R OF .
(m)
CORRELACIONES
F
( Kg / cm )
SPT
suel o
suelo
fr i ccio nant eco hesi vo
ENSAYOS DE
PENETRACION
ESTANDAR
N=
N d e g o l p es
0
10 20 30 40 50
0. 0
ML-CL
22.7
0. 5
1.00
La segunda c apa de s uelo de 1.00 m explorada, es un s uelo del tipo MLCL, con humedad
ML-CL
25.0
1. 0
27.6
1. 5
2.00
La tercera capa de suelo de 1.00 m explorada, es un suelo del tipo MLCL, com presenc ia dehumedad.
28.4
2. 0
ML-CL
27.6
2. 5
3.00
27.6
3. 0
3. 5
4.00
PANEL FOTOGRAFICO
4. 0
4. 5
5. 0
5. 5
6. 0
6. 5
7. 0
EN ESTE SONDAJE SE PUEDE OBSERVA LA EJECUCION DEL ENSAYO, ASI MSIMO SE NOTA EL
PERFIL ESTRATIGRAFICO DEL TERRENO Qadm = 1.01 kg/cm2
MA PA DE PELIGROS, PLA N DE USOS DEL SUELO ANTE DESASTRES Y MEDIDAS DE MITIGACIN DE EL TA MBO, HUANCAYO Y CHILCA
DEPARTAMENTO DE GEOTCNIA
REGISTRO DE SONDAJE
SONDAJE : SPT- 14
PROYECTO : MAPA DE PELIGROS, PLAN DE USOS DEL SUELO ANTE
DESASTRES Y MEDIDAS DE MITIGACIN DE HUANCAYO
P R OF .
(m)
S
U
C
S
CORRELACIONES
F
N
SPT
c
2
( Kg / cm )
suel o
suelo
fr i ccio nant eco hesi vo
ENSAYOS DE
PENETRACION
ESTANDAR
N=
N d e g o l p es
0
10 20 30 40 50
0. 0
ML
25.0
0. 5
1.00
26.0
1. 0
GM
13
31.1
1. 5
18
2.00
34.0
2. 0
GM
21
35.5
2. 5
22
3.00
36.0
3. 0
3. 5
4.00
PANEL FOTOGRAFICO
4. 0
4. 5
5. 0
5. 5
6. 0
6. 5
7. 0
EN ESTE SONDAJE SE PUEDE OBSERVA LA EJECUCION DEL ENSAYO, ASI MSIMO SE NOTA EL
PERFIL ESTRATIGRAFICO DEL TERRENO Qadm = 1.54 kg/cm2
MA PA DE PELIGROS, PLA N DE USOS DEL SUELO ANTE DESASTRES Y MEDIDAS DE MITIGACIN DE EL TA MBO, HUANCAYO Y CHILCA
DEPARTAMENTO DE GEOTCNIA
REGISTRO DE SONDAJE
SONDAJE : SPT- 15
PROYECTO : MAPA DE PELIGROS, PLAN DE USOS DEL SUELO ANTE
DESASTRES Y MEDIDAS DE MITIGACIN DE HUANCAYO
P R OF .
(m)
S
U
C
S
CORRELACIONES
F
N
SPT
c
2
( Kg / cm )
suel o
suelo
fr i ccio nant eco hesi vo
ENSAYOS DE
PENETRACION
ESTANDAR
N=
N d e g o l p es
0
10 20 30 40 50
0. 0
SM
25.0
0. 5
1.00
La segunda c apa de s uelo de 1.00 m explorada, es un s uelo del tipo MLCL, con humedad
ML-CL
22.7
1. 0
22.7
1. 5
2.00
22.7
2. 0
CL
23.9
2. 5
3.00
25.0
3. 0
3. 5
4.00
PANEL FOTOGRAFICO
4. 0
4. 5
5. 0
5. 5
6. 0
6. 5
7. 0
EN ESTE SONDAJE SE PUEDE OBSERVA LA EJECUCION DEL ENSAYO, ASI MSIMO SE NOTA EL
PERFIL ESTRATIGRAFICO DEL TERRENO Qadm = 1.03 kg/cm2
MA PA DE PELIGROS, PLA N DE USOS DEL SUELO ANTE DESASTRES Y MEDIDAS DE MITIGACIN DE EL TA MBO, HUANCAYO Y CHILCA
DEPARTAMENTO DE GEOTCNIA
REGISTRO DE SONDAJE
SONDAJE : SPT- 16
PROYECTO : MAPA DE PELIGROS, PLAN DE USOS DEL SUELO ANTE
DESASTRES Y MEDIDAS DE MITIGACIN DE HUANCAYO
P R OF .
(m)
S
U
C
S
CORRELACIONES
F
N
SPT
c
2
( Kg / cm )
suel o
suelo
fr i ccio nant eco hesi vo
ENSAYOS DE
PENETRACION
ESTANDAR
N=
N d e g o l p es
0
10 20 30 40 50
0. 0
SC
27.6
0. 5
1.00
27.6
1. 0
SM
13
31.1
1. 5
18
2.00
34.0
2. 0
SM
21
35.5
2. 5
22
3.00
36.0
3. 0
3. 5
4.00
PANEL FOTOGRAFICO
4. 0
4. 5
5. 0
5. 5
6. 0
6. 5
7. 0
EN ESTE SONDAJE SE PUEDE OBSERVA LA EJECUCION DEL ENSAYO, ASI MSIMO SE NOTA EL
PERFIL ESTRATIGRAFICO DEL TERRENO Qadm = 1.54 kg/cm2
MA PA DE PELIGROS, PLA N DE USOS DEL SUELO ANTE DESASTRES Y MEDIDAS DE MITIGACIN DE EL TA MBO, HUANCAYO Y CHILCA
DEPARTAMENTO DE GEOTCNIA
REGISTRO DE SONDAJE
SONDAJE : SPT- 17
PROYECTO : MAPA DE PELIGROS, PLAN DE USOS DEL SUELO ANTE
DESASTRES Y MEDIDAS DE MITIGACIN DE HUANCAYO
P R OF .
(m)
CORRELACIONES
F
N
SPT
c
2
( Kg / cm )
suel o
suelo
fr i ccio nant eco hesi vo
ENSAYOS DE
PENETRACION
ESTANDAR
N=
N d e g o l p es
0
10 20 30 40 50
0. 0
GP-GM
27.6
0. 5
1.00
La segunda c apa de s uelo de 1.00 m explorada, es un s uelo del tipo SMSC, con humedad
SM-SC
27.6
1. 0
11
29.8
1. 5
18
2.00
La tercera capa de suelo de 1.00 m explorada, es un suelo del tipo SMSC, com presencia dehumedad.
34.0
2. 0
SM-SC
21
35.5
2. 5
22
3.00
36.0
3. 0
3. 5
4.00
PANEL FOTOGRAFICO
4. 0
4. 5
5. 0
5. 5
6. 0
6. 5
7. 0
EN ESTE SONDAJE SE PUEDE OBSERVA LA EJECUCION DEL ENSAYO, ASI MSIMO SE NOTA EL
PERFIL ESTRATIGRAFICO DEL TERRENO Qadm = 1.31 kg/cm2
MA PA DE PELIGROS, PLA N DE USOS DEL SUELO ANTE DESASTRES Y MEDIDAS DE MITIGACIN DE EL TA MBO, HUANCAYO Y CHILCA
DEPARTAMENTO DE GEOTCNIA
REGISTRO DE SONDAJE
SONDAJE : SPT- 18
PROYECTO : MAPA DE PELIGROS, PLAN DE USOS DEL SUELO ANTE
DESASTRES Y MEDIDAS DE MITIGACIN DE HUANCAYO
P R OF .
(m)
S
U
C
S
CORRELACIONES
F
N
SPT
c
2
( Kg / cm )
suel o
suelo
fr i ccio nant eco hesi vo
ENSAYOS DE
PENETRACION
ESTANDAR
N=
N d e g o l p es
0
10 20 30 40 50
0. 0
ML
27.6
0. 5
1.00
27.6
1. 0
SM
11
29.8
1. 5
18
2.00
34.0
2. 0
SM
21
35.5
2. 5
22
3.00
36.0
3. 0
3. 5
4.00
PANEL FOTOGRAFICO
4. 0
4. 5
5. 0
5. 5
6. 0
6. 5
7. 0
EN ESTE SONDAJE SE PUEDE OBSERVA LA EJECUCION DEL ENSAYO, ASI MSIMO SE NOTA EL
PERFIL ESTRATIGRAFICO DEL TERRENO Qadm = 1.31 kg/cm2
MA PA DE PELIGROS, PLA N DE USOS DEL SUELO ANTE DESASTRES Y MEDIDAS DE MITIGACIN DE EL TA MBO, HUANCAYO Y CHILCA
DEPARTAMENTO DE GEOTCNIA
REGISTRO DE SONDAJE
SONDAJE : SPT- 19
PROYECTO : MAPA DE PELIGROS, PLAN DE USOS DEL SUELO ANTE
DESASTRES Y MEDIDAS DE MITIGACIN DE HUANCAYO
P R OF .
(m)
CORRELACIONES
F
N
SPT
c
2
( Kg / cm )
suel o
suelo
fr i ccio nant eco hesi vo
ENSAYOS DE
PENETRACION
ESTANDAR
N=
N d e g o l p es
0
10 20 30 40 50
0. 0
ML
27.6
0. 5
1.00
La segunda c apa de s uelo de 1.00 m explorada, es un s uelo del tipo SMSC, con humedad
SM-SC
27.6
1. 0
10
29.1
1. 5
12
2.00
La tercera capa de suelo de 1.00 m explorada, es un suelo del tipo GMGC, com pres encia dehumedad.
30.5
2. 0
GM-GC
13
31.1
2. 5
14
3.00
31.7
3. 0
3. 5
4.00
PANEL FOTOGRAFICO
4. 0
4. 5
5. 0
5. 5
6. 0
6. 5
7. 0
EN ESTE SONDAJE SE PUEDE OBSERVA LA EJECUCION DEL ENSAYO, ASI MSIMO SE NOTA EL
PERFIL ESTRATIGRAFICO DEL TERRENO Qadm = 1.20 kg/cm2
MA PA DE PELIGROS, PLA N DE USOS DEL SUELO ANTE DESASTRES Y MEDIDAS DE MITIGACIN DE EL TA MBO, HUANCAYO Y CHILCA
DEPARTAMENTO DE GEOTCNIA
REGISTRO DE SONDAJE
SONDAJE : SPT- 20
PROYECTO : MAPA DE PELIGROS, PLAN DE USOS DEL SUELO ANTE
DESASTRES Y MEDIDAS DE MITIGACIN DE HUANCAYO
P R OF .
(m)
CORRELACIONES
F
N
SPT
c
2
(Kg / cm )
suelo
suel o
f ri ccio nant eco hesivo
ENSAYOS DE
PENETRACION
ESTANDAR
N=
N d e g o l p es
0
10 20 30 40 50
0.0
GM-GC
27.6
0.5
1.00
La segunda capa de suelo de 1.00 m explorada, es un suelo del tipo MLCL, c on humedad
ML-CL
27.6
1.0
28.4
1.5
18
2.00
34.0
2.0
CL
21
35.5
2.5
22
3.00
36.0
3.0
3.5
4.00
PANEL FOTOGRAFICO
4.0
4.5
5.0
5.5
6.0
6.5
7.0
EN ESTE SONDAJE SE PUEDE OBSERVA LA EJECUCION DEL ENSAYO, ASI MSIMO SE NOTA EL
PERFIL ESTRATIGRAFICO DEL TERRENO Qadm = 1.09 kg/cm2
MA PA DE PELIGROS, PLA N DE USOS DEL SUELO ANTE DESASTRES Y MEDIDAS DE MITIGACIN DE EL TA MBO, HUANCAYO Y CHILCA
DEPARTAMENTO DE GEOTCNIA
REGISTRO DE SONDAJE
SONDAJE : SPT- 21
PROYECTO : MAPA DE PELIGROS, PLAN DE USOS DEL SUELO ANTE
DESASTRES Y MEDIDAS DE MITIGACIN DE HUANCAYO
P R OF .
(m)
CORRELACIONES
F
N
SPT
c
2
(Kg / cm )
suelo
suel o
f ri ccio nant eco hesivo
ENSAYOS DE
PENETRACION
ESTANDAR
N=
N d e g o l p es
0
10 20 30 40 50
0.0
ML
26.0
0.5
10
1.00
La segunda capa de suelo de 1.00 m explorada, es un suelo del tipo MLCL, c on humedad
ML-CL
29.1
1.0
23.9
1.5
2.00
La tercera capa de suelo de 1.00 m explorada, es un suelo del tipo MLCL, c om presencia dehumedad.
22.7
2.0
ML-CL
22.7
2.5
3.00
25.0
3.0
3.5
4.00
PANEL FOTOGRAFICO
4.0
4.5
5.0
5.5
6.0
6.5
7.0
EN ESTE SONDAJE SE PUEDE OBSERVA LA EJECUCION DEL ENSAYO, ASI MSIMO SE NOTA EL
PERFIL ESTRATIGRAFICO DEL TERRENO Qadm = 0.89 kg/cm2