SRAVANTI

INTRODUCTION:

THIS IS A PROJECT OF MINISTRY OF


ENVIRONMENT AND FORESTS FOR
CONSTRUCTION OF NEW OFFICE
BUILDING AT NEW DELHI.

THE BASIC DESIGN CONCEPT OF


THE PROJECT IS TO MAKE THE NET
ZERO ENERGY GREEN BUILDING.

PLOT AREA:9565sq m
MAXIMUM GROUND
COVERAGE:30%

F.A.R: 200
HEIGHT:35m
Built-up area : 3,1400 m2
, (18726 m2 superstructure &
12675 m2
- Basement)
Year of completion : 2013

PRIMARY ROAD
(AUROBINDO MARG)

LOCATION AND ACCESSIBILITY:

THE SITE IS SURROUNDED ON EAST BY NDMC HOUSING AND 15M. ROW, ON WEST BY
12M ROW AND ON NORTH LODHI COLONY AND 12M. ROW, ON SOUTH GPRA COLONY
OF ALIGANJ.
THE PLOT IS EASILY APPROACHABLE FROM AUROBINDO MARG AND LODHI ROAD.
A METRO STATION "JORBAGH" IS AT WALKABLE DISTANCE OF ABOUT 300M FROM THIS
PLACE.

ACHIEVEMENTS:

40% SAVINGS IN ENERGY


ZERO ELECTRICITY BILLING
55% SAVINGS IN WATER
ZERO NET DISHARGE
LARGEST ROOF TOP SOLAR
POWER SYSTEM IN ANY
MULTISTOREYED BUILDING
(930KWP)
FIRST IN GOVERNMENT SECTOR
TARGETED FOR BOTH RATINGS OF
GREEN BUILDING (5STAR GRIHA
LEED
India PLATINUM)

CRITERIONS OF GRIHA FULFILLED


SITE PLANNING
NO.

CRITERION

POINTS

Site selection

Preserve and protect landscape during construction

Soil conservation (till post-construction)

Design to include existing site features

Reduce hard paving on-site and/or provide shaded


hard-paved surfaces

Enhance outdoor lighting system efficiency and


use renewable energy system for meeting outdoor
lighting requirements

Plan utilities efficiently and optimize on-site


circulation efficiency

3
SOURCE: GRIHA WEBSITE

MEASURES FOR SITE


Wider Front Setback (22m) to protect front tree line
Preserve the integrity of the green street
Preservation of the local ecology, Tree Cutting approvals for 46, but only 19
cut
- 11 Trees Transplanted
- Excavated Soil reutilized at other construction sites and the Zoo
The IPB office building for the ministry of
environment and forests has been planned in 2
parallel blocks facing the
north south direction, with a large linear
open court in the centre.The Building blocks
create a porous block form to optimize
air movement throughout the site and the NS orientation allows for optimum solar access
and shading.

EFFECTIVE VENTILATION BY ORIENTATING THE BUILDING E-W AND BY OPTIMUM


INTEGRATION WITH NATURE BY SEPARATING OUT DIFFERENT BLOCKS WITH CONNECTING
CORRIDORS AND A HUGE CENTRAL COURT YARD.

W
N

More than 50% area outside


the building is soft
with plantation and grassing.
circulation roads and pathways
soft with grass paver blocks
to enable ground water recharge

BUILDING PLANNING AND CONSTRUCTION STAGE


NO.

CRITERION

POINTS

10

Reduce landscape water requirement

11

Reduce water use in the building

12

Efficient water use during construction

13

Optimize building design to reduce conventional


energy demand

14

Optimize energy performance of building within


specified comfort limits

16

15

Utilization of fly-ash in building structure

16

Reduce volume, weight, and construction time by


adopting efficient technologies (such as pre-cast systems)

4
SOURCE: GRIHA WEBSITE

BUILDING PLANNING AND CONSTRUCTION MEASURES


Reduce landscape water requirementDrip irrigation
Use of native species of shrubs and trees having low water demand in landscaping
Low lawn area so as to reduce water demand.
Reuse of treated water for irrigation
Reduce water use in the buildingLow discharge fixtures
Dual Flushing cistern
Waste water treatment
Reuse of treated water for irrigation and cooling towers for HVAC
Rain water harvesting
Efficient water use during constructionUse of curing compound

Site and Water Mgmt Strategies


Appropriate Shading from Summer Sun, while allowing in winter sun

Optimize building design to reduce conventional energy demand.

ENERGY EFFICIENT LIGHT FITTINGS TO REDUCE ENERGY DEMAND


PART CONDENSER WATER HEAT REJECTION BY GEOTHERMAL MECHANISM. THIS WILL ALSO
HELP IN WATER CONSERVATION IN COOLING TOWERS FOR HVAC SYSTEM
VARIABLE CHILLED WATER PUMPING SYSTEM THROUGH VFD.VFD ON COOLING TOWERS
FANS AND AHU.
PRE COOLING OF FRESH AIR FROM TOILET EXHAUST AIR THROUGH SENSIBLE & LATENT
HEAT ENERGY RECOVERY WHEEL
ENTIRE HOT WATER GENERATION THROUGH SOLAR PANELS.
MAXIMUM DAYLIGHTING
REGENERATIVE LIFTS.
USE OF LUX LEVEL SENSOR TO OPTIMIZE OPERATION OF ARTIFICIAL LIGHTING.
SOLAR POWERED EXTERNAL LIGHTING.

Optimize energy performance of building within


specified comfort limits Reducing energy consumption (compared to GRIHA benchmarks) while
maintaining occupant comfort:
o For achieving visual comfort:
Dire t li e of sight to the outdoor e iro e t to isio glazi g for uildi g
occupants for more than 90% of the occupied spaces.
Avoiding Deep floor plates to create maximum daylighted spaces.
La ds api g pla ed ith ati e spe ies a d ater ody features i e tral
court and all around the building.
o For achieving thermal comfort:
All ir ulatio spa es or passages ere aturally e tilated / shaded / ot air
conditioned.
E ergy Effi ie t Chilled ea
ased Cooli g syste proposed together ith
condenser water cooling through ground pipes.
Ope a le i do s ere proposed i o ditio ed areas to e a le to utilize
favourable outdoor conditions.
I sulated Walls through usi g a i tegrated AAC + Ro k ool o i atio
together ith high effi ie y DGUs a d UPVC
frames for the windows.

Energy Conservation Measures

Utilization of fly-ash in building structureReady Mix Concrete with PPC having more than 30% fly ash content.

FLY ASH = 40 %

Reduce volume, weight, and construction time by


adopting efficient technologies (such as pre-cast systems)ON SITE RENEWABLE ENERGY SYSTEM WITH SOLAR PHOTOVOLTAIC CELLS TO MEET TOTAL
ENERGY DEMAND.

RECYCLE,RECHARGE &REUSE
NO.
CRITERION

POINTS

17

Use low-energy material in interiors

18

Renewable energy utilization

19

Renewable-energy-based hot water system

20

Waste water treatment

21

Water recycle and reuse (including rainwater)

5
SOURCE: GRIHA WEBSITE

WASTE MANAGEMENT
NO.

CRITERION

POINTS

22

Reduction in waste during construction

23

Efficient waste segregation

24

Storage and disposal of wastes

25

Resource recovery from waste

2
SOURCE: GRIHA WEBSITE

HEALTH &WELL BEING

NO.

CRITERION

POINTS

26

Use low-VOC paints/adhesives/sealants

27

Minimize ozone depleting substances

28

Ensure water quality

29

Acceptable outdoor and indoor noise levels

30

Tobacco smoke control

31

Provide at least the minimum level of accessibility for persons


with disabilities

32

Energy audit and validation

MANDATORY

33

Operation and maintenance

34

Innovation points

4
SOURCE: GRIHA WEBSITE

Highest efficiency (20%) Solar PV panels


Grid Interactive System

NET ZERO ENERGY

SOLAR PV SYSTEM
TOTAL AREA
TOTAL AREA OF PANELS
ANNUAL ENERGY Generation

930KWp CAPACITY
6000 M2
4650 M2
14.3 lakh units

20

SOURCE- AR,DEEPENDRA PARSAAD REPORT

CHILLED BEAMS INDUCTION


UNITS OVERVIEW:
Primary air ventilation
from Dedicated Outdoor
Air Source

Chilled Water
Hot Water

Total room mixing


is achieved
through
Convection
currents
within the space

CHILLED BEAM INSTALLED


AT SITE:
Chilled Water Return Pipe ( dia.)
Chilled Beam

Chilled Water Supply Pipe ( dia.)

23

Drain Pipe ( dia.)

Flexible Duct (6 Inch dia.)

Supply
Air
Induce
d Air

GEOTHERMAL HEAT EXCHANGE


AT SITE:
There are 180 vertical bores at the
Depth of 80 meter all along the
Building Premises. Minimum 3
meter distance is maintained
between any two bores.
Each bore is lowered with HDPE
pipe U-loop (32mm outer Dia.) and
grouted with Bentonite Slurry.
Each U-Loop is connected to MS
Header Pipe(100mm Dia.)which
finally joins the Condenser Water
Line in Plant Room.
Condenser hot water is sent at
100F (37.8 C) & back at 900 F
(32.2 C).
One U-Loop has
0.9 TR Heat
Rejection capacity, so all together
160 TR of Heat rejection is obtained
without using a cooling tower.
Enormous water saving since no
make up water is required.
Make up water pumping &
treatment cost get eliminated.
Saves cooling tower fan energy.

MATERIALS
Stone available in nearby area for flooring
Terrazzo flooring with locally available stone
materials.
Fly ash brick.
AAC blocks.
Jute bamboo composite for door frames &
shutters.
UPVC windows with hermetically sealed double
using low heat transmittance index glass.
Use of high reflectance terrace tiles for low heat
ingress.
Avoided aluminum as it has high embedded
energy
Sandstone Jalis.
Stone and Ferrocement Jalis

Satisfies all the quality parameters that


a normal flush door does

Bamboo Jute Composite Doors and frames & flooring


High Efficiency Glass, high VLT, low SHGC & Low U-value,
Optimized by shading
Light Shelves for bringing in diffused sunlight
Use of material available having Recycled content

Das könnte Ihnen auch gefallen