The half wave ac controller uses one thyristor and one diode connected in parallel across each
other in opposite direction as show. The output voltage across the load resistor R, is
flows through the thyristor T1, the load and through the transformer secondary winding.
The output voltage across the load follows the input supply voltage when the thyristor T 1 is
turned-on and when it conducts from t = to radians. When the input supply voltage
decreases to zero at t = , for a resistive load the load current also falls to zero at t = and
hence the thyristor T1 turns off at t = . Between the time period t = to 2, when the
supply voltage reverses and becomes negative the diode D 1 becomes forward biased and
hence turns on and conducts. The load current flows in the opposite direction during t = to
2 radians when D1 is on and the output voltage follows the negative half cycle of input
supply.
VO RMS VS
1
sin 2
2
2
2
IT Avg
Im
1 cos
2
IT RMS I m
1
sin 2
4
2
The output load voltage has a DC component because the two halves of the output voltage
These drawbacks of single phase half wave ac voltage controller can be overcome by using a
single phase full wave ac voltage controller.
Single phase full wave AC voltage controller circuit using two SCRs or a single TRIAC is
generally used in most of the ac control applications. A single phase full wave ac voltage
controller with a resistive load is shown in the figure below. It is possible to control the ac
power flow to the load in both the half cycles by adjusting the trigger angle . Hence the full
wave ac voltage controller is also referred to as to a bi-directional controller.
The thyristor T1 is forward biased during the positive half cycle of the input supply voltage.
The thyristor T1 is triggered at a delay angle of . Considering the on thyristor T 1 as an ideal
closed switch the input supply voltage appears across the load resistor R and the output
voltage, vO is same as input voltage, v S during t = to radians. The load current flows
through the conducting thyristor T1 and through the load resistor R in the downward direction
in this period. At t = , when the input voltage falls to zero the thyristor current falls to zero
and hence T1 naturally turns off. No current flows in the circuit during t = to (+ ).
The thyristor T2 is forward biased during the negative cycle of input supply and when
thyristor T2 is triggered at a delay angle (+ ), the output voltage follows the negative half
cycle of input from t = (+ ) to 2. When T 2 is on, the load current flows in the reverse
direction (upward direction). The time interval between the gate trigger pulses of T 1 and T2 is
kept at radians. At t = 2 the input supply voltage falls to zero and hence the load current
also falls to zero and thyristor T2 turns off naturally.
Instead of using two SCRs in parallel, a TRIAC can be used for full wave ac voltage
control.
VL RMS VS
1
sin 2
O (R M S )
0 .6 V
0 .2 V
60
120
180
T r ig g e r a n g le in d e g r e e s
In practice most of the loads are of RL type. For example a single phase full wave ac voltage
controller controlling the speed of a single phase ac induction motor, the load which is the
induction motor winding is an RL type of load, where R represents the motor winding
resistance and L represents the motor winding inductance.
A single phase full wave ac voltage controller circuit with an RL load using two thyristors T 1
The thyristor T1 will continue to conduct the load current until all the inductive energy stored
in the load inductor L is completely utilized and the load current through T 1 falls to zero at t
= , where is called as the extinction angle, at which the load current falls to zero.
The
V 1
sin 2 sin 2
m
2
2
2
This circuit, AC voltage controller can be used to regulate the RMS voltage across the
terminals of an ac motor. It can be used to control the temperature of a furnace by varying the
vO
vO= vS
Vm
iO
Im