Sie sind auf Seite 1von 3

COMPRESSOR TECHNICAL DATA

COMPRESSOR DEFINITION
Designation
Nominal Voltage/Frequency
Engineering Number

NB Y1118Y
220-240 V 50 Hz
816BA47

A - APPLICATION / LIMIT WORKING CONDITIONS


1 Type

Hermetic reciprocating compressor

2 Refrigerant

R-600a

3 Nominal voltage and frequency

220-240 / 50

[ V / Hz ]

4 Application type
4.1 Evaporating temperature range

Low Back Pressure


-35C to -10C

(-31F to 14F)

5 Motor type

RSCR

6 Starting torque

LST - Low Starting Torque

7 Expantion device

Capillary tube
Operating voltage range

8 Compressor cooling

T
N

8.1 LBP (32C Ambient temperature)

Static

50 Hz
198 to 254 V

8.2 LBP (43C Ambient temperature)

Static

198 to 254 V

8.3 HBP (32C Ambient temperature)

8.4 HBP (43C Ambient temperature)

E
-

9 Maximum condensing pressures/temperature


9.1 Operating (gauge)

7.7

9.2 Peak (gauge)

9.8

10 Maximum winding temperature


B - MECHANICAL DATA
1 Commercial designation

O
L

2 Displacement

14.28

2.1 Bore [mm]


2.2 Stroke [mm]
3 Lubricant charge
3.1 Lubricants approved

30.157
20.000
280

E
V

3.2 Lubricants type/viscosity


4 Weight (with oil charge)
5 Nitrogen charge
C - ELETRICAL DATA

E
D

/ C - F

[kgf/cm] (139 psig)


[ C ]

/ C - F

[hp]

[cm] (0.871 cu.in)

[ml] (9.47 fl.oz.)

MINERAL / ISO7
10.6

[kg]

[kgf/cm]

(23.37 lb.)

1 Nominal Voltage/Frequency/Number of Phases

220-240 V 50 Hz 1 ~ (Single phase)

2 Starting device type


2.1 Starting device

PTC
V230

3 Start capacitor

[kgf/cm] (109 psig)

M
P

130

60 Hz
-

[F(VAC minimum)]

4 Run capacitor

4(450)

[F(VAC minimum)]

5 Motor protection

T0062/07

6 Start winding resistance

23.20

7 Run winding resistance

15.20

8 LRA - Locked rotor amperage (50 Hz)

[A] - Measured according to UL 984

[W at 25C (77F)] +/- 8%


[W at 25C (77F)] +/- 8%

9 FLA - Full load amperage L/MBP (50 Hz)

[A] - Measured according to UL 984

10 FLA - Full Load Amperage HBP (50 Hz)

[A] - Measured according to UL 984

11 Approval boards certification

VDE

UPDATE: 29APR2008

816BA47

COMPRESSOR TECHNICAL DATA


D - PERFORMANCE - CHECK POINT DATA
TEST CONDITIONS:
@220V50Hz

CECOMAFLBP
Static
Current
Power
consumption consumption

Cooling capacity
+/- 5%
[kcal/h]
158

[Btu/h]
625

+/- 5%
[A]
0.63

+/- 5%
[W]

[W]
183

133

Evaporating temperature

-25C (-13F)

(Condensing temperature

55C (131F))

Gas flow
rate
+/- 5%
[kg/h]
2.38

EFFICIENCY RATE
+/- 7%
[kcal/Wh]
1.18

[Btu/Wh]
4.70

[W/W]
1.38

E - PERFORMANCE - CURVES
TEST CONDITIONS:
@220V50Hz
Evaporating
temperature

Cooling capacity

Power
consumption

+/- 5%

+/- 5%

+/- 5%

+/- 5%

[W]

[A]

[kg/h]

(F)

[Btu/h]

[kcal/h]

-35
-30
-25
-20
-15
-10

(-31)
(-22)
(-13)
(- 4)
(+ 5)
(+14)

462
591
772
1007
1295
1640

116
149
195
254
326
413

TEST CONDITIONS:
@220V50Hz
Evaporating
temperature

[W]
135
173
226
295
380
481

+/- 5%
[Btu/h]

[kcal/h]

-35
-30
-25
-20
-15
-10

(-31)
(-22)
(-13)
(- 4)
(+ 5)
(+14)

426
543
702
907
1158
1457

107
137
177
229
292
367

(F)

-35
-30
-25
-20
-15
-10

(-31)
(-22)
(-13)
(- 4)
(+ 5)
(+14)

UPDATE: 29APR2008

0.44
0.49
0.55
0.61
0.67
0.74

125
159
206
266
339
427

E
D

[kcal/h]

M
P

O
L

+/- 5%

+/- 5%

[W]

[A]

[kg/h]

98
111
125
140
157
175

361
472
617
800
1021
1281

91
119
156
202
257
323

106
138
181
234
299
375

[kcal/Wh]

5.15
5.84
6.75
7.84
9.06
10.35

1.30
1.47
1.70
1.98
2.28
2.61

[W/W]
1.51
1.71
1.98
2.30
2.65
3.03

0.46
0.52
0.59
0.66
0.73
0.82

1.48
1.89
2.45
3.16
4.05
5.10

EFFICIENCY RATE
+/- 7%
[Btu/Wh]

[kcal/Wh]

4.36
4.90
5.61
6.45
7.37
8.32

1.10
1.23
1.41
1.63
1.86
2.10

[W/W]
1.28
1.44
1.64
1.89
2.16
2.44

(Condensing temperature 55C (+131F) )

Power
consumption
[W]

[Btu/Wh]

Current
Gas flow rate
consumption

CECOMAF
Static

[Btu/h]

T
N

+/- 7%

1.48
1.90
2.48
3.23
4.17
5.29

+/- 5%

E
V

Cooling capacity

EFFICIENCY RATE

(Condensing temperature 45C (+113F) )

[W]

+/- 5%

90
102
115
128
143
158

Power
consumption

Cooling capacity

(F)

Evaporating
temperature

Current
Gas flow rate
consumption

CECOMAF
Static

TEST CONDITIONS:
@220V50Hz

(Condensing temperature 35C (+95F) )

CECOMAF
Static

Current
Gas flow rate
consumption

+/- 5%

+/- 5%

+/- 5%

[W]

[A]

[kg/h]

100
115
132
150
170
192

0.48
0.55
0.62
0.70
0.79
0.89

1.38
1.80
2.35
3.05
3.91
4.92

EFFICIENCY RATE
+/- 7%
[Btu/Wh]

[kcal/Wh]

3.63
4.08
4.66
5.32
6.01
6.69

0.91
1.03
1.17
1.34
1.51
1.69

[W/W]
1.06
1.19
1.36
1.56
1.76
1.96

816BA47

COMPRESSOR TECHNICAL DATA


F - EXTERNAL CHARACTERISTICS
1 Base plate

European Standard

2 Tray holder

No

3 Connectors
3.1 SUCTION

6.1 +0.10/+0.00

3.1.1 Material

Copper

3.1.2 Shape

Slanted 42

3.2 DISCHARGE

4.94 +0.08/-0.08

[mm]

(0.240" +0.004"/+0.000")

[mm]

(0.194" +0.003"/-0.003")

3.2.1 Material

Copper

3.2.2 Shape

Slanted parallel to Base Plate

3.3 PROCESS

[mm]

6.1 +0.10/+0.00

3.3.1 Material

Copper

3.3.2 Shape

Slanted 42

3.4 Oil cooler (Copper)

No

3.5 Connector sealing

Rubber Plugs

(0.240" +0.004"/+0.000")

T
N

[mm]

M
P

O
L

E
V

E
D
UPDATE: 29APR2008

816BA47

Das könnte Ihnen auch gefallen