Sie sind auf Seite 1von 24

WIT-PE 500 R

WIT-PE 500 with rebar


WIT-PE 500

Approved for:
Concrete C20/25 to C50/60, cracked
Suitable for:
Concrete C12/15, Natural stone with dense structure

385 ml
Artnr.: 0903480001

1400 ml
Artnr.: 0903480002

8 - 40

Benefits:
Europ
Benefits:
The prolonged gelling/working time allows
convenient adjustment at higher temperature and
with large embedment depth.
Its many approvals guarantees optimized load
capacities for threaded rods and rebar.
Its specially developed chemical composition allows
a reliable installation in underwater conditions and
when filled in diamond cored drill holes.
The low shrinkage of the mortar broadens the
application spectrum in addition for big diameter
fastener elements.

Applications

Approvals and Certificates

Xx1

Description

Authority/
Laboratory

Guideline
for Assessment

No./date of issue

European Technical Approval


European Technical Approval
ICC-ES Evaluation Report
Fire resistance
Test Report LEED
VOC Emissions Test report
NSF International

DIBt, Berlin
DIBt, Berlin
ICC
MPA Braunschweig
eurofins
eurofins
NSF International

ETAG 001-T5
TR 023 / EC 2
AC 308
TR 020
Leed 2009 EQ c4.1
DEVL 1101903D, DEVL 1104875A
NSF/ANSI Standard61

ETA-09/0040 / 2013-06-14
ETA-07/0313 / 2013-05-30
ESR-2538 / 2012-05-01
3302/252/08-N13/2009-01-07
G15982K / 2012-10-30
2013-03-13
2013-11-13

All data in this section applies to:


Correct setting (See setting instruction).
No edge distance and spacing influence.
Base material thickness, as specified in the table.
Embedment depth, as specified in the table.
Anchor material, as specified in the tables,
steel grade BST 500 S, B500B.

Concrete C 20/25, fck,cube = 25 N/mm,


Concrete C 50/60, fck,cube = 60 N/mm.
Temperate range I (min. base material temperature
-40C, max. long term/short term base material
temperature: +24C/40C).
Dry or wet conditions of drill hole, hammer drilling.
Installation temperature range +5C to +40C.

WIT-PE 500 R

Basic loading data (for a single anchor)

Characteristic resistance
Anchor type: WIT-PE 500 R
8 10 12 14 16

Rebar size
Effective anchorage depth

hef,typ

[mm]

80

90

110

125

125

20 25 28 32 40
170

210

270

300

360

Non-cracked concrete
Tensile

C20/25

NRk

[kN]

28.1

39.6

53.9

70.6

70.6 111.9 153.7 224.0 262.4 344.9

C50/60

NRk

[kN]

31.0

43.5

59.3

77.6

77.6 123.1 169.0 246.5 288.6 379.4

C20/25

VRk

[kN]

13.8

21.6

31.1

42.3

55.3

86.4 135.0 169.3 221.2 345.6

Tensile

C20/25

NRk

[kN]

31.1

38.5

40.8

64.1

87.1 126.0 165.9

C50/60

NRk

[kN]

34.2

42.3

44.9

70.5

95.8 138.6 182.5

Shear

C20/25

VRk

[kN]

31.1

42.3

55.3

86.4 135.0 169.3 221.2

Shear
Cracked concrete

Design resistance
Anchor type: WIT-PE 500 R
8

Rebar size
Effective anchorage depth

10 12 14 16

20 25 28 32 40

hef,typ

[mm]

80

90

110

125

125

170

210

270

300

360

Non-cracked concrete
Tensile
Shear

C20/25

NRd

[kN]

15.6

22.0

29.9

39.2

39.2

53.3

73.2 106.7 125.0 164.3

C50/60

NRd

[kN]

17.2

24.2

32.9

43.1

43.1

58.6

80.5 117.4 137.5 180.7

C20/25

VRd

[kN]

9.2

14.4

20.7

28.2

36.9

57.6

90.0 112.9 147.4 230.4

Cracked concrete
Tensile
Shear

C20/25

NRd

[kN]

17.3

21.4

22.7

30.5

41.5

60.0

79.0

C50/60

NRd

[kN]

19.0

23.5

25.0

33.6

45.6

66.0

86.9

C20/25

VRd

[kN]

20.7

28.2

36.9

57.6

90.0 112.9 147.4

Xx2

WIT-PE 500 R

WIT-PE 500 with rebar


Recommended / Allowable loads1)
Anchor type: WIT-PE 500 R
8

Rebar size
Effective anchorage depth

hef,typ

[mm]

80

Non-cracked concrete

10 12 14 16
90

110

20 25 28 32 40

125

125

170

210

270

300

Benefits:
Europ 28.0
15.7 21.4

28.0

38.1

52.3

76.2

89.3 117.3
98.2 129.1

Tensile

C20/25

Nrec

[kN]

11.2

C50/60

Nrec

[kN]

12.3

17.3

23.5

30.8

30.8

41.9

57.5

83.8

Shear

C20/25

Vrec

[kN]

6.6

10.3

14.8

20.2

26.3

41.1

64.3

80.6 105.3 164.6

Tensile

C20/25

Nrec

[kN]

12.3

15.3

16.2

21.8

29.6

42.8

56.4

C50/60

Nrec

[kN]

13.6

16.8

17.8

24.0

32.6

47.1

62.1

Shear

C20/25

Vrec

[kN]

14.8

20.2

26.3

41.1

64.3

80.6 105.3

Cracked concrete

1)

Xx3

360

Material safety factor yM and safety factor for action y L = 1.4 are included. The material safety factor depends on the failure mode.

Simplified version of the design method according ETAG 001, TR 029. Design resistance
according data given in ETA-09/0040, issue 2013-06-14:
Influence of concrete strength.
Influence of edge distance.
Influence of spacing.
Valid for a group of anchors. (The influencing factors must then be considered for each edge distance and spacing.
The calculated design loads are then on the save side. They will be lower than the exact values according
ETAG 001, Annex C. To avoid this, it is recommended to use the anchor design software of Wrth).
The design method is based on the following simplification: No different loads are acting on individual anchors
(no eccentricity).
Temperate range I (min. base material temperature -40C, max. long term/short term base material temperature:
+24C/40C).
Dry or wet conditions of drill hole, hammer drilling.
Installation temperature range +5C to +40C.
40 not part of ETA, data based on in-house testing according to guideline.

WIT-PE 500 R

Design Method (simplified)

Tension loading
The decisive design resistance in tension is the lowest value of the following failure modes:
Steel failure:
Combined Pull out and concrete cone failure:
Concrete cone failure:
Concrete splitting failure:

Design steel resistance

of a single anchor

Anchor type: WIT-PE 500 R


Code

BS4449:1997
DIN1045-1:2008:08/
DIN 488-1:2009:08 /
DIN EN 1992-1-1:
2011-01

Rebar
grade

Rebar
size

460A

NRd,s

460B

NRd,s

BST
500 S,
B500B

NRd,s

10

12

14

16

20

25

28

32

40

[kN]

17.4

27.1

39.0

53.1

69.4

108.4 169.4 212.4 277.4 433.7

[kN]

17.8

27.9

40.1

54.6

71.3

111.5 174.2 218.5 285.4 445.9

[kN]

19.7

30.9

44.4

60.5

79.0

123.4 192.8 241.9 316.0 493.7

Xx4

WIT-PE 500 R

WIT-PE 500 with rebar


Design combined pull-out and concrete cone resistance

of a single anchor

Basic design combined pull-out and concrete cone resistance


Anchor type: WIT-PE 500 R

Benefits:

Europ16
14

10

12

20

25

28

32

40

[mm]

80

90

110

125

125

170

210

270

300

360

[kN]

15.6

22.0

29.9

39.7

41.9

61.0

82.9

120.0

158.0

172.3

17.3

21.4

22.7

30.5

41.5

60.0

79.0

Rebar size
hef,typ

of a single anchor

Non-cracked concrete
N0Rd,p
Cracked concrete
N0Rd,p

[kN]

Influence of concrete strength


Concrete strength classes
(EN 206:2000)

C12/15 C16/20 C20/25 C25/30 C30/37 C35/45 C40/50 C45/55 C50/60

Characteristic compressive strength


of concrete determined by testing
cylinders1)

fck,cyl

[N/mm2]

12

16

20

25

30

35

40

45

50

Characteristic compressive strength of


concrete determined by testing cube2)

fck,cube

[N/mm2]

15

20

25

30

37

45

50

55

60

Influencing factor

fb,N

[-]

0.77

0.89

1.00

1.02

1.04

1.06

1.08

1.09

1.10

1)

strength at 28days of 150mm diameter by 300mm cylinders.

2)

strength at 28days of 150mm cubes.

Influence of embedment depth

Consider the approved range of embedment


anchor characteristics.

Xx5

according to the table

Anchor type: WIT-PE 500 R


8

10

12

14

16

20

25

28

32

40

hef,typ

[mm]

80

90

110

125

125

170

210

270

300

360

scr,p

[mm]

194

242

277

323

360

438

526

575

681

826

ccr,p

[mm]

97

121

139

162

180

219

263

287

341

413

Rebar size

WIT-PE 500 R

Characteristic edge distance ccr,p and spacing scr,p

Concrete cone failure - Influence of spacing

Number of

s/scr,p1)

0.10

0.15

0.20

0.25

0.30

0.35

0.40

0.45

0.50

0.55

0.60

0.65

0.70

0.75

0.80

0.85

0.90

0.95

1.0

fsx,p, fsy,p

0.55

0.58

0.60

0.63

0.65

0.68

0.70

0.73

0.75

0.78

0.80

0.83

0.85

0.88

0.90

0.93

0.95

0.98

1.00

fsx,p, fsy,p

0.40

0.43

0.47

0.50

0.53

0.57

0.60

0.63

0.67

0.70

0.73

0.77

0.80

0.83

0.87

0.90

0.93

0.97

1.00

fsx,p, fsy,p

0.33

0.36

0.40

0.44

0.48

0.51

0.55

0.59

0.63

0.66

0.70

0.74

0.78

0.81

0.85

0.89

0.93

0.96

1.00

fsx,p, fsy,p

0.28

0.32

0.36

0.40

0.44

0.48

0.52

0.56

0.60

0.64

0.68

0.72

0.76

0.80

0.84

0.88

0.92

0.96

1.00

fixing per
direction

1)

Choose always the lowest value of the spacing s, when there are different spacings in one row.

Concrete cone failure - Influence of edge distance

;
c/ccr,p

0.10

0.15

0.20

0.25

0.30

0.35

0.40

0.45

0.50

0.55

0.60

0.65

0.70

0.75

0.80

0.85

0.90

0.95

1.0

fcx,1,p

0.73

0.75

0.76

0.78

0.79

0.81

0.82

0.84

0.85

0.87

0.88

0.90

0.91

0.93

0.94

0.96

0.97

0.99

1.00

0.55

0.58

0.60

0.63

0.65

0.68

0.70

0.73

0.75

0.78

0.80

0.83

0.85

0.88

0.90

0.93

0.95

0.98

1.00

fcx,2,p
fcy,p

Design concrete cone resistance

and splitting resistance

of a single anchor

Concrete cone failure:


Concrete splitting failure:
No verification of splitting is required if at least one of the conditions is fulfilled:
a) The edge distance in all directions is
for single fasteners and
for fastener groups and the
member depth is
in both cases.
b) The characteristic resistance for concrete cone failure and pull-out failure is calculated for cracked concrete and
reinforcement resists the splitting forces and limits the crack width to
.

Xx6

WIT-PE 500 R

WIT-PE 500 with rebar


Basic design concrete cone resistance

of a single anchor

Anchor type: WIT-PE 500 R


8 10 12 14 16 20 25

Rebar size
hef,typ

[mm]

80

90

110

125

N0Rd,c

125

170

210
73.2
52.3

[kN]

20.1

24.0

32.4

Benefits:
Europ 53.3
39.2 39.2

[kN]

14.3

17.1

23.1

28.0

Non-cracked concrete

28 32 40
270

300

360

106.7 125.0 164.3

Cracked concrete
N0Rd,c

28.0

38.1

76.2

89.3 117.3

Influence of concrete strength

Concrete strength classes


(EN 206:2000)

1)
2)

C12/15 C16/20 C20/25 C25/30 C30/37 C35/45 C40/50 C45/55 C50/60

Characteristic compressive strength of


concrete determined by testing
cylinders1)

fck,cyl

[N/mm2]

12

16

20

25

30

35

40

45

50

Characteristic compressive strength of


concrete determined by testing cube2)

fck,cube

[N/mm2]

15

20

25

30

37

45

50

55

60

Influencing factor

fb,N

[-]

0.77

0.89

1.00

1.10

1.22

1.34

1.41

1.48

1.55

strength at 28days of 150mm diameter by 300mm cylinders.


strength at 28days of 150mm cubes.

Influence of embedment depth

Consider the approved range of embedment depth


anchor characteristics.

Xx7

according to the table

Characteristic edge distance ccr,N and spacing scr,N


Anchor type: WIT-PE 500 R
8

Rebar size

10

12

14

16

20

25

28

32

40

hef,typ

[mm]

80

90

110

125

125

170

210

270

300

360

scr,N

[mm]

240

270

330

375

375

510

630

810

900

1080

ccr,N

[mm]

120

135

165

188

188

255

315

405

450

540

WIT-PE 500 R

Concrete cone failure

Above characteristic spacing and edge distances are given for the typical effective anchorage depth. Calculating for
smaller depths is leading to conservative load capacities. For calculation with bigger depths use the following:
and
.

Concrete cone failure - Influence of spacing

Number of

s/scr,N1)

0.10

0.15

0.20

0.25

0.30

0.35

0.40

0.45

0.50

0.55

0.60

0.65

0.70

0.75

0.80

0.85

0.90

0.95

1.0

fsx, fsy

0.55

0.58

0.60

0.63

0.65

0.68

0.70

0.73

0.75

0.78

0.80

0.83

0.85

0.88

0.90

0.93

0.95

0.98

1.00

fsx, fsy

0.40

0.43

0.47

0.50

0.53

0.57

0.60

0.63

0.67

0.70

0.73

0.77

0.80

0.83

0.87

0.90

0.93

0.97

1.00

fsx, fsy

0.33

0.36

0.40

0.44

0.48

0.51

0.55

0.59

0.63

0.66

0.70

0.74

0.78

0.81

0.85

0.89

0.93

0.96

1.00

fsx, fsy

0.28

0.32

0.36

0.40

0.44

0.48

0.52

0.56

0.60

0.64

0.68

0.72

0.76

0.80

0.84

0.88

0.92

0.96

1.00

fixing per
direction

1)

Choose always the lowest value of the spacing s, when there are different spacings in one row.

Concrete cone failure - Influence of edge distance

c/ccr,N

0.10

0.15

0.20

0.25

0.30

0.35

0.40

0.45

0.50

0.55

0.60

0.65

0.70

0.75

0.80

0.85

0.90

0.95

1.0

fcx,1

0.73

0.75

0.76

0.78

0.79

0.81

0.82

0.84

0.85

0.87

0.88

0.90

0.91

0.93

0.94

0.96

0.97

0.99

1.00

0.55

0.58

0.60

0.63

0.65

0.68

0.70

0.73

0.75

0.78

0.80

0.83

0.85

0.88

0.90

0.93

0.95

0.98

1.00

fcx,2
fcy

Xx8

WIT-PE 500 R

WIT-PE 500 with rebar


Concrete splitting failure
Characteristic edge distance ccr,sp and spacing scr,sp
Anchor type: WIT-PE 500 R
8

10

12

14

16

20

25

28

32

40

hef,typ

[mm]

80

90

110

125

125

170

210

270

300

360

scr,sp

[mm]

360

420

528

816

1008

1296

1440

1728

ccr,sp

[mm]

180

210

264

300

300

408

504

648

720

864

hmin

[mm]

110

120

134

153

157

210

258

324

364

440

Rebar size

Benefits:
600
600
Europ

Above characteristic spacing and edge distances are given for the typical effective anchorage depth. Calculating for
smaller depths is leading to conservative load capacities. For calculation with bigger depths use the following:
and
and

according to the table anchor characteristics.

Concrete splitting failure - Influence of spacing

Number of

s/scr,sp1)

0.10

0.15

0.20

0.25

0.30

0.35

0.40

0.45

0.50

0.55

0.60

0.65

0.70

0.75

0.80

0.85

0.90

0.95

1.0

fsx,sp, fsy,sp

0.55

0.58

0.60

0.63

0.65

0.68

0.70

0.73

0.75

0.78

0.80

0.83

0.85

0.88

0.90

0.93

0.95

0.98

1.00

fsx,sp, fsy,sp

0.40

0.43

0.47

0.50

0.53

0.57

0.60

0.63

0.67

0.70

0.73

0.77

0.80

0.83

0.87

0.90

0.93

0.97

1.00

fsx,sp, fsy,sp

0.33

0.36

0.40

0.44

0.48

0.51

0.55

0.59

0.63

0.66

0.70

0.74

0.78

0.81

0.85

0.89

0.93

0.96

1.00

fsx,sp, fsy,sp

0.28

0.32

0.36

0.40

0.44

0.48

0.52

0.56

0.60

0.64

0.68

0.72

0.76

0.80

0.84

0.88

0.92

0.96

1.00

fixing per
direction

1)

Choose always the lowest value of the spacing s, when there are different spacings in one row.

Concrete splitting failure - Influence of edge distance

c/ccr,sp

0.10

0.15

0.20

0.25

0.30

0.35

0.40

0.45

0.50

0.55

0.60

0.65

0.70

0.75

0.80

0.85

0.90

0.95

1.0

fcx,1, sp

0.73

0.75

0.76

0.78

0.79

0.81

0.82

0.84

0.85

0.87

0.88

0.90

0.91

0.93

0.94

0.96

0.97

0.99

1.00

0.55

0.58

0.60

0.63

0.65

0.68

0.70

0.73

0.75

0.78

0.80

0.83

0.85

0.88

0.90

0.93

0.95

0.98

1.00

fcx,2, sp
fcy, sp

Xx9

h/hmin

1.00

1.10

1.20

1.30

1.40

1.50

1.60

1.70

1.80

1.90

2.00

2.10

2.20

2.30

2.40

2.50

2.60

2.70

2.80

2.90

fh

1.00

1.07

1.13

1.19

1.25

1.31

1.37

1.42

1.48

1.53

1.59

1.64

1.69

1.74

1.79

1.84

1.89

1.94

1.99

2.00

WIT-PE 500 R

Concrete splitting failure - Influence of concrete member thickness

Shear loading
The decisive design resistance in shear is the lowest value of the following failure modes:
Steel failure:
Concrete pry-out failure:
Concrete edge failure:

Design steel resistance

of a single anchor

Anchor type: WIT-PE 500 R


Code

BS4449:1997
DIN1045-1:2008:08 /
DIN 488-1:2009:08 /
DIN EN 1992-1-1:
2011-01

Rebar
grade

Rebar
size

460A

VRd,s

460B

VRd,s

BST
500 S,
B500B

VRd,s

10

12

14

16

20

25

[kN]

8.1

12.6

18.2

24.8

32.4

50.6

79.0

99.1 129.5 202.3

[kN]

8.3

13.0

18.7

25.5

33.3

52.0

81.3

102.0 133.2 208.1

[kN]

9.2

14.4

20.7

28.2

36.9

57.6

90.0

112.9 147.4 230.4

Design concrete pry-out resistance

28

32

40

of a single anchor

Anchor type: WIT-PE 500 R


Rebar size
hef,typ

[mm]

[-]

10

12

14

16

20

25

28

32

40

80

90

110

125

125

170

210

270

300

360

Xx10

WIT-PE 500 R

WIT-PE 500 with rebar


Design concrete edge resistance

Verification of concrete edge failure may be omitted for single fasteners and groups with an edge distance in all
directions
. For anchorages with more than one edge, the resistance for all edges shall be
calculated. The smallest value should be used in the verification.
Benefits:
Europ
Basic design concrete edge resistance
of a single anchor
Anchor type: WIT-PE 500 R
8

10

12

14

16

20

25

28

32

40

[kN]

5.2

7.5

10.1

13.1

16.4

24.3

36.3

42.3

50.5

68.0

[kN]

3.7

5.3

7.1

9.2

11.6

17.1

25.6

29.7

35.5

47.8

Rebar size
Non-cracked concrete
V0Rd,c
Cracked concrete
V0Rd,c

Influence of concrete strength

Concrete strength classes


(EN 206:2000)

1)
2)

C12/15 C16/20 C20/25 C25/30 C30/37 C35/45 C40/50 C45/55 C50/60

Characteristic compressive strength of


concrete determined by testing
cylinders1)

fck,cyl

[N/mm2]

12

16

20

25

30

35

40

45

50

Characteristic compressive strength of


concrete determined by testing cube2)

fck,cube

[N/mm2]

15

20

25

30

37

45

50

55

60

Influencing factor

fb,V

[-]

0.77

0.89

1.00

1.10

1.22

1.34

1.41

1.48

1.55

strength at 28days of 150mm diameter by 300mm cylinders.


strength at 28days of 150mm cubes.

Influence of embedment depth


hef /d
fhef,V

10

11

12

0.87

0.91

0.94

0.97

1.00

1.02

1.05

1.07

1.08

Influence of edge distance c1


c1 /d
fc1,V

Xx11

12

15

20

30

40

50

60

100

150

200

0.47

1.19

2.05

2.76

4.05

6.96

10.22

13.76

17.54

34.66

59.52

87.35

WIT-PE 500 R

Influence of load direction

1)

1)

f,V

10

20

30

40

50

60

70

80

90

1.00

1.01

1.05

1.11

1.20

1.34

1.51

1.72

1.92

2.00

For 90 the component of the shear load acting away from the edge may be neglected and the verification may
be done with component acting parallel to the edge only.

Influence of spacing
In groups loaded perpendicular to the edge only two adjacent anchors closest and parallel to the edge carry the load.
The smallest spacing should be used for the verification.

1)

s/c11)

0.50

0.60

0.70

0.80

0.90

1.00

1.20

1.40

1.60

1.80

2.00

2.20

2.40

2.60

2.80

3.00

fs,V

1.17

1.20

1.23

1.27

1.30

1.33

1.40

1.47

1.53

1.60

1.67

1.73

1.80

1.87

1.93

2.00

Choose always the lowest value of the spacing s, when there are different spacings in the row closest to the edge.

Influence of second edge distance

1)

c2/c11)

1.00

1.10

1.20

1.30

1.40

1.50

fc,V

0.75

0.80

0.85

0.90

0.95

1.00

Distance to the second edge: c1 c2.

Influence of concrete member thickness

h/c1

0.10

0.20

0.30

0.40

0.50

0.60

0.70

0.80

0.90

1.00

1.10

1.20

1.30

1.40

1.50

fh,V

0.26

0.37

0.45

0.52

0.58

0.63

0.68

0.73

0.77

0.82

0.86

0.89

0.93

0.97

1.00

Xx12

WIT-PE 500 R

WIT-PE 500 with rebar


Structural Verification
Tension

Benefits:
Europ
Shear

Combined tension and shear

Xx13

Temperature range

Base material
temperature

Maximum long term base


material temperature

Maximum short term base


material temperature

Temperature range I

-40 C to +40 C

+24 C

+40 C

Temperature range II

-40 C to +60 C

+43 C

+60 C

Temperature range III

-40 C to +72 C

+43 C

+72 C

WIT-PE 500 R

Service temperature

Design bond strength for different use categories


Anchor type: WIT-PE 500 R
Non-cracked concrete
8

Rebar size

10

12

14

16

20

25

28

32

40

Design bond strength according to ETA-09/0040 / dry and wet concrete / hammer drilling
Temperature range I
Temperature range II
Temperature range III

Rd,ucr

[N/mm2]

7.8

7.8

7.2

7.2

6.7

5.7

5.2

5.2

5.2

3.8

[N/mm ]

4.7

4.7

4.4

4.4

4.2

3.3

3.3

3.1

3.1

2.1

Rd,ucr

[N/mm2]

4.2

4.2

4.2

3.9

3.9

3.1

2.9

2.9

2.9

1.9

Rd,ucr

[N/mm2]

6.7

6.2

5.2

4.8

4.5

4.0

3.6

3.3

2.9

[N/mm ]

4.0

4.0

3.8

3.8

3.6

3.3

2.9

2.6

2.4

Rd,ucr

[N/mm2]

3.6

3.6

3.6

3.3

3.3

2.9

2.6

2.4

2.1

Rd,ucr

[N/mm2]

7.3

5.6

5.6

5.6

5.3

5.0

[N/mm ]

4.7

3.6

3.6

3.3

3.3

3.1

Rd,ucr

[N/mm2]

4.0

3.3

3.3

3.1

2.8

2.8

Rd,ucr

[N/mm2]

6.0

5.6

5.6

5.3

5.3

4.7

[N/mm2]

3.7

3.6

3.6

3.3

3.3

3.1

Rd,ucr

[N/mm ]

3.3

3.3

3.1

3.1

2.8

2.8

10

12

14

16

20

25

28

32

Rd,ucr

Design bond strength according to ETA-09/0040 / flooded concrete / hammer drilling


Temperature range I
Temperature range II
Temperature range III

Rd,ucr

Design bond strength according to ETA-11/0398 / dry and wet concrete / diamond drilling
Temperature range I
Temperature range II
Temperature range III

Rd,ucr

Design bond strength according to ETA-11/0398 / flooded concrete / diamond drilling


Temperature range I
Temperature range II
Temperature range III
Cracked concrete

Rd,ucr

Rebar size

40

Design bond strength according to ETA-09/0040 / dry and wet concrete / hammer drilling
Temperature range I
Temperature range II
Temperature range III

Rd,cr

[N/mm2]

4.2

3.9

3.6

2.9

2.6

2.6

2.6

[N/mm ]

2.5

2.2

2.2

1.7

1.7

1.7

1.7

Rd,cr

[N/mm2]

2.2

1.9

1.9

1.4

1.4

1.4

1.4

Rd,cr

[N/mm2]

3.6

3.1

2.9

2.4

2.1

1.9

1.9

[N/mm2]

2.1

1.9

1.9

1.7

1.7

1.7

1.4

Rd,cr

[N/mm ]

1.9

1.9

1.9

1.4

1.4

1.4

1.4

Rd,cr

Design bond strength according to ETA-09/0040 / flooded concrete / hammer drilling


Temperature range I
Temperature range II
Temperature range III

Rd,cr

Xx14

WIT-PE 500 R

WIT-PE 500 with rebar


Reduction factor for different use categories
Anchor type: WIT-PE 500 R
Non-cracked concrete
8

Rebar size

10

12

14

16

20

25

28

32

40

Reduction factor strength according to ETA-09/0040 / dry and wet concrete / hammer drilling
Temperature range I
Temperature range II
Temperature range III

Benefits:

f.red

1.00

1.00

1.00

0.61

0.61

0.62

f.red

0.54

0.54

0.58

f.red

0.86

0.80

0.73

0.66

0.52

0.52

0.53

0.53

f.red

0.46

0.46

0.49

0.46

f.red

1.00
1.00
Europ

1.00

1.00

1.00

1.00

1.00

0.62

0.63

0.58

0.64

0.59

0.59

0.56

0.54

0.58

0.54

0.55

0.55

0.55

0.50

0.68

0.71

0.68

0.64

0.55

0.54

0.58

0.55

0.50

0.45

0.50

0.50

0.50

0.45

0.41

Reduction factor according to ETA-09/0040 / flooded concrete / hammer drilling


Temperature range I
Temperature range II
Temperature range III

f.red

Reduction factor according to ETA-11/0398 / dry and wet concrete / diamond drilling
Temperature range I
Temperature range II
Temperature range III

f.red

1.20

1.00

1.00

1.05

1.23

1.17

0.76

0.65

0.65

0.63

0.78

0.71

f.red

0.65

0.60

0.60

0.58

0.65

0.65

f.red

0.98

1.00

1.00

1.00

1.23

1.10

0.60

0.65

0.65

0.63

0.78

0.71

f.red

0.55

0.60

0.55

0.58

0.65

0.65

10

12

14

16

20

25

28

32

f.red

Reduction factor according to ETA-11/0398 / flooded concrete / diamond drilling


Temperature range I
Temperature range II
Temperature range III
Cracked concrete

f.red

Rebar size

Reduction factor according to ETA-09/0040 / dry and wet concrete / hammer drilling
Temperature range I
Temperature range II
Temperature range III

f.red

1.00

1.00

1.00

1.00

1.00

1.00

1.00

0.60

0.57

0.62

0.58

0.64

0.64

0.64

f.red

0.53

0.50

0.54

0.50

0.55

0.55

0.55

f.red

0.86

0.80

0.79

0.83

0.82

0.73

0.73

0.51

0.49

0.53

0.58

0.64

0.64

0.55

f.red

0.46

0.49

0.53

0.50

0.55

0.55

0.55

f.red

Reduction factor according to ETA-09/0040 / flooded concrete / hammer drilling


Temperature range I
Temperature range II
Temperature range III

Xx15

f.red

40

Anchor type: WIT-PE 500 R


8

Rebar size

10

12

14

16

20

25

28

32

40

hef,min

[mm]

60

60

70

75

80

90

100

112

128

160

hef,max

[mm]

96

120

144

168

192

240

300

336

384

480

Nominal drill hole


diameter

d0

[mm]

12

14

16

18

20

24

32

35

40

50

Drill depth

h0 / h1 [mm]

Min. thickness of
concrete member

hmin

[mm]

Minimum spacing

smin

[mm]

40

50

60

70

80

100

125

140

160

200

Minimum edge distances

cmin

[mm]

40

50

60

70

80

100

125

140

160

200

Effective anchorage depth

WIT-PE 500 R

Anchor characteristics

= hef
= hef +30mm 100mm

= hef + 2d0

hmin
h0

d0

hef

Xx16

WIT-PE 500 R

WIT-PE 500 with rebar


Mechanical characteristics
Anchor type: WIT-PE 500 R
rebar grade

460A

BS4449:
1997

460B

DIN1045-1:
2008:08 /
DIN 488-1:
2009:08 /
DIN EN 19921-1: 2011-01

Xx17

BST 500 S,
B500B

8 10 12 14 16 20

Rebar size

25

28 32 40

Stressed
cross
section

As

[mm]

50

Benefits:
79 113 154
Europ

201

314

Section
Modulus

[mm]

50

98

170

269

402

785 1534 2155 3217 6283

Yield
strength

fy

[N/mm2] 460

460

460

460

460

460

460

460

460

460

Tensile
strength

fu

[N/mm2] 483

483

483

483

483

483

483

483

483

483

Design
bending
moment

M0Rd,s

[Nm]

19

38

66

104

155

303

593

833 1243 2428

Yield
strength

fy

[N/mm2] 460

460

460

460

460

460

460

460

460

460

Tensile
strength

fu

[N/mm2] 497

497

497

497

497

497

497

497

497

497

Design
bending
moment

M0Rd,s

[Nm]

20

39

67

107

160

312

610

857 1279 2497

Yield
strength

fy

[N/mm2] 500

500

500

500

500

500

500

500

500

500

Tensile
strength

fu

[N/mm2] 550

550

550

550

550

550

550

550

550

550

Design
bending
moment

M0Rd,s

[Nm]

43

75

119

177

346

675

948 1415 2765

22

491

616

804 1257

Abstract of EN 1992-1-1 Annex C, Table C.1, Properties of reinforcement


Product form

Bars and de-coild rods

Class

Characteristic yield strenght fyk or f0,2k (N/mm2)

WIT-PE 500 R

Material specification of rebar

400 to 600

Minimum value of k=(ft /fy)k

1,15
<1,35

1,08

Characteristic strain at maximum force uk (%)

5,0

Bendability

7,5
Bend / Rebend test

Nominal bar size (mm)


Maximum deviation from nominal mass
8
(individual bar) (%)
>8

6,0
4,5

Abstact of EN 1992-1-1 Annex C, Table C.2N, Properties of reinforcement


Product form

Bars and de-coild rods

Class

Min. value of related rip area fRmin

Nominal diameter
of the rebar (mm)
8 to 12
>12

0,040
0,056

Rlb height of the bar shall be in the range: 0,05d h 0,07d


(d: Nominal diameter of the bar; h: Rlp height of the bar)

Working time and curing time


Temperature
of Concrete
5C bis 9C

Gelling - working time


60 min

Minimum Curing time


in dry concrete
72 h

Minimum Curing time


in wet concrete
142 h

10C bis 19C

45 min

45 h

90 h

20C bis 29C

30 min

10 h

20 h

30C bis 39C

20 min

6 h

12 h

40C

12 min

4 h

8h

Xx18

WIT-PE 500 R

WIT-PE 500 with rebar


Filling Quantity
Anchor type: WIT-PE 500 R
Thread size
Nominal drill hole
diameter

d0

[mm]

Drill depth

h0 / h1

[mm]

Filling volume per 10mm


embedment depth
Assumed wastage of 15% included.

Xx19

[ml]

10

12

12

14

16

0.80

0.96

1.11

14

16

20

25

28

32

40

18

20

24

32

35

40

50

2.21

2.70

4.30

5.64

8.77

Benefits:
Europ
1.27

1.45

= hef

Anchor type: WIT-PE 500 R

or

Installation

Control

Choose the right tools.

There is a clearly defined set of tools


for producing a safe fixture: drilling
machine, drill bit, hand-pump, brush,
brush diameter gauge. (See table
Accessories)
Check availability of those system tools
before starting.

Drill hole to the required embedment depth with a hammer


drill set in rotation-hammer mode using an appropriately
sized carbide drill bit.(for drill bit diameter and drill hole
depth (see table Anchor characteristics)

Working length of drill bit must be


bigger than the given drill hole
depth.

Blow out at least 2x from the back of the bore hole until
return air stream is free of noticeable dust.
If the back of the bore hole is not reached an extension
shall be used.
The hand-pump can be used for anchor sizes up to bore
hole diameter 20 mm. For bore holes larger than 20 mm
or deeper 240 mm, compressed air (min. 6 bar) must be
used.

The compressed air without oil.

Brush 2x with the specified brush size by inserting the


brush to the back of the hole in a twisting motion and
removing it.
If the back of the hole is not reached with the brush,
a brush extension shall be used.

The brush must produce natural


resistance as it enters the drill hole if not, the brush is too small and
must be replaced with the proper
brush diameter (use the brush
diameter gauge).

WIT-PE 500 R

Installation instruction

Blow out at least 2x from the back of the bore hole until
return air stream is free of noticeable dust.
If the back of the bore hole is not reached an extension
shall be used.
The hand-pump can be used for anchor sizes up to bore
hole diameter 20 mm. For bore holes larger than 20 mm
or deeper 240 mm, compressed air (min. 6 bar) must be
used.
Prior to inserting the anchor rod into the filled bore hole,
the position of the embedment depth shall be marked on
the anchor rods.

Before use, verify that the anchor


element is dry and free of oil and
other contaminants.

Xx20

WIT-PE 500 R

WIT-PE 500 with rebar


Installation

Control

Tightly attach mixing nozzle to cartridge.


Place the cartridge into dispensing gun.
Do not modify the mixing nozzle.

Only use mixing nozzle and


dispensing gun of the system.

Benefits:
Europ
Discard initial adhesive. An initial amount of 10cm
adhesive has to be discarded.
Visual check if resin is evenly in colour.
For every working interruption longer than the
recommended working time as well as for new cartridges,
a new mixing nozzle shall be used.
(see table Working and cure times)
Inject the adhesive starting at the back of the hole, slowly
withdrawing the mixer with each trigger pull.
Fill holes approximately 2/3 full, or as required to ensure
that the annular gap between the anchor and the concrete
is completely filled with adhesive along the embedment
length.
For embedment larger than 190mm an extension nozzle
shall be used.
For overhead and horizontal installation in bore holes
larger than 20mm a injection adapter and extension
nozzle shall be used.

Marking the mixing nozzle makes


it easier to fill every hole with the
same volume.

Press the marked anchor element down to the bottom of


the hole, turning it slightly while doing so.
After inserting the anchor element, excess mortar must
emerge from the annular gap.

If these requirements (excess mortar


and the embedment depth) are not
maintained, the application has to
be renewed.
For overhead installation fix
embedded part (e.g.wedges).

Do not move or load the anchor until the mortar is fully


cured. (see table Working and cure times)

After required curing time, the anchor element can be


loaded.
The applied installation torque shall not exceed.
(see table Anchor characteristic)

Xx21

Check the max. torque by using a


calibrated torque wrench.

Anchor type: WIT-PE 500 R


Thread size
Nominal drill hole diameter

d0

[mm]

Drill depth

h 0 / h1

[mm]

10

12

14

16

20

25

28

32

40

12

14

16

18

20

24

32

35

40

50

WIT-PE 500 R

Accessoires

= hef

Hammer Drills
H 36-MAS / H24-MLS (SDS-plus)
BMH 32-XE (SDS-Plus)
BMH 40-XES (SDS-Max)
BMH 45-XE (SDS-Max)

Drill Bits
LONGLIFE QUADRO-L (0648 xxx yyy)
LONGLIFE QUADRO-L (0647 0xx yyy)
QUADRO-S (0647 7xx yyy)

Brush
8

Thread size

10

12

14

16

20

25

28

32

40

41.5

52

Brush diameter

db

[mm]

14

16

18

20

22

26

34

37

Brush length

lb

[mm]

170

200

200

300

300

300

300

300

...010

...012

...014

...016

...020

...025

... 028

25

28

Brush
0905 489 ...

...008

on demand

0903 489 111

Brush extension

0903 489 099

Brush diameter gauge

0903 489 101

SDS adapter for machine cleaning

Blow-out (manual)
Thread size
Blow-out pump (manual)

10

12

14

16

20

32

40

0903 990 001

Xx22

WIT-PE 500 R

WIT-PE 500 with rebar


Compressed-air cleaning
Thread size
Jet nozzle
0903 489 ...

10

... 210

12

14

16

... 214

Thread adapter

20

... 217

28

32

40

32

40

... 227

0903 489 291

0903 489 292

0699 903 7

0699 903 13

Benefits:
Europ

Hose

25

Injecting
Thread size

10

12

14

16

20

Dispensing gun

0891 009

Pneumatic dispenser 385

0891 017

Pneumatic dispenser 1400

0891 015

25

0903 488 101

Mixer nozzle
Mixer extension 10

0903 488 123


0903 488 122

Mixer extension 16
Injection adapter (repulsion piston)
0903 488 ...

Xx23

28

...008

...010

...012

...014

...016

...020

...025

...028

Chemical Agent
Acetic acid
Laitance
Acetone
Ammonia, aqueous solution
Aniline
Beer
Chlorine
Benzol
Boric Acid, aqueous solution
Calcium carbonate, suspended in water
Calcium chloride, suspended in water
Calcium hydroxide, suspended in water
Carbon tetrachloride
Caustic soda solution
Citric acid
Diesel oil
Ethyl alcohol, aqueous solution
Formic acid
Formaldehyde, aqueous solution
Freon
Fuel Oil
Gasoline (premium grade)
Glycol (Ethylene glycol)
Hydrochloric acid (Muriatic Acid)
Hydrogen peroxide
Isopropyi alcohol
Lactic acid
Linseed oil
Lubricating oil
Magnesium chloride, aqueous solution
Methanol
Motor oil (SAE 20 W-50)
Nitric acid
Oleic acid
Perchloroethylene
Petroleum
Phenol, aqueous solution
Phosphoric acid
Phosphoric acid
Potash lye (Potassium hydroxide, 10% and 40% solution)
Potassium carbonate, aqueous solution
Potassium chlorite, aqueous solution
Potassium nitrate, aqueous solution
Sodium carbonate
Sodium Chloride, aqueous solution
Sodium phosphate, aqueous solution
Sodium silicate
Sulfuric acid
Tartaric acid
Tetrachloroethylene
Toluene
Trichloroethylene
Turpentine

Concentration
40
10
5
100
100
All
100
All
100
40
All
100
50
100
30
100
Conc.
30
100
All
100
100
All
100
100
10
100
100
100
8
85
10
All
All
All
All
All
All
All
30
All
100
100
100

Resistant

Not Resistant

WIT-PE 500 R

Chemical resistanace

Xx24

Das könnte Ihnen auch gefallen